RIM-ONE: An open retinal image database for optic nerve evaluation

Automated diagnosis of glaucoma disease has been studied for years. A great amount of research work in this field has been focused on the analysis of retinal fundus images to localize, detect and evaluate the optic disc. An open fundus image database with accurate gold standards of the optic nerve h...

Full description

Saved in:
Bibliographic Details
Published in2011 24th International Symposium on Computer-Based Medical Systems (CBMS) pp. 1 - 6
Main Authors Fumero, F., Alayon, S., Sanchez, J. L., Sigut, J., Gonzalez-Hernandez, M.
Format Conference Proceeding
LanguageEnglish
Published IEEE 01.06.2011
Subjects
Online AccessGet full text
ISBN9781457711893
1457711893
ISSN1063-7125
DOI10.1109/CBMS.2011.5999143

Cover

Abstract Automated diagnosis of glaucoma disease has been studied for years. A great amount of research work in this field has been focused on the analysis of retinal fundus images to localize, detect and evaluate the optic disc. An open fundus image database with accurate gold standards of the optic nerve head has been implemented. A variability measurement by zones of the optic disc is also proposed. The relevance of this work is to provide accurate ONH segmentations and a segmentation assessment procedure to allow the design of computerized methods for glaucoma detection.
AbstractList Automated diagnosis of glaucoma disease has been studied for years. A great amount of research work in this field has been focused on the analysis of retinal fundus images to localize, detect and evaluate the optic disc. An open fundus image database with accurate gold standards of the optic nerve head has been implemented. A variability measurement by zones of the optic disc is also proposed. The relevance of this work is to provide accurate ONH segmentations and a segmentation assessment procedure to allow the design of computerized methods for glaucoma detection.
Author Fumero, F.
Sigut, J.
Alayon, S.
Gonzalez-Hernandez, M.
Sanchez, J. L.
Author_xml – sequence: 1
  givenname: F.
  surname: Fumero
  fullname: Fumero, F.
  email: franfumero@isaatc.ull.es
  organization: Dept. of Syst. Eng., Univ. of La Laguna, La Laguna, Spain
– sequence: 2
  givenname: S.
  surname: Alayon
  fullname: Alayon, S.
  organization: Dept. of Syst. Eng., Univ. of La Laguna, La Laguna, Spain
– sequence: 3
  givenname: J. L.
  surname: Sanchez
  fullname: Sanchez, J. L.
  organization: Dept. of Syst. Eng., Univ. of La Laguna, La Laguna, Spain
– sequence: 4
  givenname: J.
  surname: Sigut
  fullname: Sigut, J.
  organization: Dept. of Syst. Eng., Univ. of La Laguna, La Laguna, Spain
– sequence: 5
  givenname: M.
  surname: Gonzalez-Hernandez
  fullname: Gonzalez-Hernandez, M.
  organization: Dept. of Ophthalmology, Hosp. Univ. de Canarias, Spain
BookMark eNotUNtKw0AUXLGCbc0HiC_7A4l7sresb22pWmgteHkuu9uzshI3JYkF_96AmZdhGGYYZkYmqUlIyC2wAoCZ-9Vy91aUDKCQxhgQ_ILMQEitAQzTlyQzuhp1ZfiETIEpnmso5TXJuu6LDVCqGqJTsnzd7PL9y_qBLhJtTphoi31Mtqbx234iPdreOtshDU07-H30NGF7RopnW__YPjbphlwFW3eYjTwnH4_r99Vzvt0_bVaLbR5Byz4X3jnkWFoHJghQSvPSeYlWK8_QWw0egxcSeXADrKiMPFbMA6gAHDifk7v_3oiIh1M7DGx_D-MF_A_tXE6Z
ContentType Conference Proceeding
DBID 6IE
6IH
CBEJK
RIE
RIO
DOI 10.1109/CBMS.2011.5999143
DatabaseName IEEE Electronic Library (IEL) Conference Proceedings
IEEE Proceedings Order Plan (POP) 1998-present by volume
IEEE Xplore All Conference Proceedings
IEEE Electronic Library (IEL)
IEEE Proceedings Order Plans (POP) 1998-present
DatabaseTitleList
Database_xml – sequence: 1
  dbid: RIE
  name: IEEE Electronic Library (IEL)
  url: https://proxy.k.utb.cz/login?url=https://ieeexplore.ieee.org/
  sourceTypes: Publisher
DeliveryMethod fulltext_linktorsrc
Discipline Medicine
EISBN 1457711907
9781457711886
1457711885
9781457711909
EndPage 6
ExternalDocumentID 5999143
Genre orig-research
GroupedDBID 29O
6IE
6IH
ACGFS
ALMA_UNASSIGNED_HOLDINGS
CBEJK
M43
RIE
RIO
ID FETCH-LOGICAL-i175t-4cbbe3e2ab19f4166732bc5ea76c0eca71cefc45e3fbbbba4895d80c116f13133
IEDL.DBID RIE
ISBN 9781457711893
1457711893
ISSN 1063-7125
IngestDate Wed Aug 27 03:32:30 EDT 2025
IsPeerReviewed false
IsScholarly true
Language English
LinkModel DirectLink
MergedId FETCHMERGED-LOGICAL-i175t-4cbbe3e2ab19f4166732bc5ea76c0eca71cefc45e3fbbbba4895d80c116f13133
PageCount 6
ParticipantIDs ieee_primary_5999143
PublicationCentury 2000
PublicationDate 2011-June
PublicationDateYYYYMMDD 2011-06-01
PublicationDate_xml – month: 06
  year: 2011
  text: 2011-June
PublicationDecade 2010
PublicationTitle 2011 24th International Symposium on Computer-Based Medical Systems (CBMS)
PublicationTitleAbbrev CBMS
PublicationYear 2011
Publisher IEEE
Publisher_xml – name: IEEE
SSID ssj0000668991
ssj0004713
Score 2.3618054
Snippet Automated diagnosis of glaucoma disease has been studied for years. A great amount of research work in this field has been focused on the analysis of retinal...
SourceID ieee
SourceType Publisher
StartPage 1
SubjectTerms Biomedical optical imaging
Gold
Hospitals
Image segmentation
Optical imaging
Retina
Title RIM-ONE: An open retinal image database for optic nerve evaluation
URI https://ieeexplore.ieee.org/document/5999143
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV1LT8JAEJ4AB-PJBxjf2YNHF9hu26XehEDQpGhUEm5kdztNiKEYUy7-emfbAtF4sKc-Dm03k51vvvlmBuBGW-wJP0i51C7N6CcpN54W3IbSOAAhFDq-I56E46n_OAtmNbjd1sIgYiE-w7Y7LXL5ycquHVXWCRya8WUd6mRmZa3Wlk8h10mhw07eQZtuKa4PJVfkxYuirkApAtSR3PR62lxX6U7RjTqDfvxadvas3vZj7ErhdUYHEG--txSbvLfXuWnbr1-tHP_7Q4fQ2tX3seet5zqCGmbHsBdXafYm9F8eYv40Gd6x-4y5-VrM1TqSybHFkvYf5mSlzv0xQrz0nGyPZU45yXa9w1swHQ3fBmNeDVvgC0IQOfetMSjR00ZEKaG0UEnP2AC1Cm0XrVbCYmr9AGVq6NB-LwqSXtcKEaZCUqR7Ao1sleEpMCQU5imjTaIp-gzRqNRaJKQVGa08E51B0y3F_KPspzGvVuH879sXsF_yuI75uIRG_rnGKwICubkuLOAbooSq-g
linkProvider IEEE
linkToHtml http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV1LT8JAEN4gJurJBxjf7sGjC2y326XehEBAKRqFhBvZ3U4TYizGwMVf72xbIBoP9tTHoe1mst83M9_MEHKjLTS5LxMmtEsz-nHCjKc5s4EwjkBwBS7eEQ2D3th_mMhJidyua2EAIBOfQc2dZrn8eG6XLlRWl47N-GKLbCPu-zKv1lpHVBA80XnYCDxw283l9YFgCnE8K-uSSiGlDsWq29Pqukh48kZYb7ei17y3Z_G-H4NXMtzp7pNo9cW53OSttlyYmv361czxv790QKqbCj_6vMauQ1KC9IjsREWivUJaL_2IPQ07d_Q-pW7CFnXVjmh0dPaOOxB1wlIHgBQ5Lz5H66Op007STffwKhl3O6N2jxXjFtgMOcSC-dYYEOBpw8MEeVqghGesBK0C2wCrFbeQWF-CSAwe2m-GMm42LOdBwgX6useknM5TOCEUkId5ymgTa_Q_AzAqsRaQa4VGK8-Ep6TilmL6kXfUmBarcPb37Wuy2xtFg-mgP3w8J3t5VNfFQS5IefG5hEukBQtzlVnDN89erkc
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Abook&rft.genre=proceeding&rft.title=2011+24th+International+Symposium+on+Computer-Based+Medical+Systems+%28CBMS%29&rft.atitle=RIM-ONE%3A+An+open+retinal+image+database+for+optic+nerve+evaluation&rft.au=Fumero%2C+F.&rft.au=Alayon%2C+S.&rft.au=Sanchez%2C+J.+L.&rft.au=Sigut%2C+J.&rft.date=2011-06-01&rft.pub=IEEE&rft.isbn=9781457711893&rft.issn=1063-7125&rft.spage=1&rft.epage=6&rft_id=info:doi/10.1109%2FCBMS.2011.5999143&rft.externalDocID=5999143
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1063-7125&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1063-7125&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1063-7125&client=summon