Study of Frequency Response with Centralized vs. Distributed Placement of Battery Energy Storage Systems in Renewable Integrated Microgrid

Due to a number of benefits, share of renewable energy based generation is increasing rapidly. However, intermittent behavior of renewable energy is challenging to keep the frequency stable; specially in isolated microgrids. Deploying battery energy storage system (BESS) in microgrid could be helpfu...

Full description

Saved in:
Bibliographic Details
Published in2017 IEEE International WIE Conference on Electrical and Computer Engineering (WIECON ECE) pp. 96 - 99
Main Authors Arif, Shaila, Aziz, Tareq
Format Conference Proceeding
LanguageEnglish
Published IEEE 01.12.2017
Subjects
Online AccessGet full text
DOI10.1109/WIECON-ECE.2017.8468928

Cover

Abstract Due to a number of benefits, share of renewable energy based generation is increasing rapidly. However, intermittent behavior of renewable energy is challenging to keep the frequency stable; specially in isolated microgrids. Deploying battery energy storage system (BESS) in microgrid could be helpful to lessen such frequency excursion problems. This paper investigates the effect of various placement strategies of BESS in an isolated renewable integrated microgrid. BESS has been placed in centralized as well as in distributed manner throughout the test microgrid. Results show that, in comparison to centralized placement, distributed placement of BESS offers better frequency response with events such as large load connection.
AbstractList Due to a number of benefits, share of renewable energy based generation is increasing rapidly. However, intermittent behavior of renewable energy is challenging to keep the frequency stable; specially in isolated microgrids. Deploying battery energy storage system (BESS) in microgrid could be helpful to lessen such frequency excursion problems. This paper investigates the effect of various placement strategies of BESS in an isolated renewable integrated microgrid. BESS has been placed in centralized as well as in distributed manner throughout the test microgrid. Results show that, in comparison to centralized placement, distributed placement of BESS offers better frequency response with events such as large load connection.
Author Arif, Shaila
Aziz, Tareq
Author_xml – sequence: 1
  givenname: Shaila
  surname: Arif
  fullname: Arif, Shaila
  organization: Department of Electrical & Electronic Engineering, Ahsanullah University of Science & Technology, Dhaka, Bangladesh
– sequence: 2
  givenname: Tareq
  surname: Aziz
  fullname: Aziz, Tareq
  organization: Department of Electrical & Electronic Engineering, Ahsanullah University of Science & Technology, Dhaka, Bangladesh
BookMark eNot0NFKwzAYBeAICurcE3hhXqA1SdukvdTa6WA6cYqXI2n_1EiXziRz1Efwqd1wV4cDh-_inKNj21tA6IqSmFJSXL9Pq3L-FFVlFTNCRZynPC9YfoTOaZbknHFGilM09v6TEMJ4nuaMn6HfRdg0A-41njj42oCtB_wCft1bD3hrwgcuwQYnO_MDDf72Mb4zPjijNmHXnztZw2o32AO3MgRwA64suHbAi9A72QJeDD7AymNjd7CFrVQd4KkN0Dq5Nx5N7frWmeYCnWjZeRgfcoTeJtVr-RDN5vfT8mYWGSqyECWKceBSUw0NSKoKqqTSqQBBGsVEopqC8ZoxUaRcZVoIrVTNUpUxIQmRkIzQ5b9rAGC5dmYl3bA83JX8AXOXZ9M
ContentType Conference Proceeding
DBID 6IE
6IL
CBEJK
RIE
RIL
DOI 10.1109/WIECON-ECE.2017.8468928
DatabaseName IEEE Electronic Library (IEL) Conference Proceedings
IEEE Xplore POP ALL
IEEE Xplore All Conference Proceedings
IEEE/IET Electronic Library
IEEE Proceedings Order Plans (POP All) 1998-Present
DatabaseTitleList
Database_xml – sequence: 1
  dbid: RIE
  name: IEEE Electronic Library (IEL)
  url: https://proxy.k.utb.cz/login?url=https://ieeexplore.ieee.org/
  sourceTypes: Publisher
DeliveryMethod fulltext_linktorsrc
EISBN 1538626209
9781538626207
1538626217
9781538626214
EndPage 99
ExternalDocumentID 8468928
Genre orig-research
GroupedDBID 6IE
6IF
6IL
6IN
AAJGR
AAWTH
ABLEC
ALMA_UNASSIGNED_HOLDINGS
BEFXN
BFFAM
BGNUA
BKEBE
BPEOZ
CBEJK
IEGSK
OCL
RIE
RIL
ID FETCH-LOGICAL-i175t-3b26e6af1fedea1b91babf47e70db273bd926c227946b5f77fbbc24b527a00ae3
IEDL.DBID RIE
IngestDate Wed Aug 27 02:51:30 EDT 2025
IsPeerReviewed false
IsScholarly false
Language English
LinkModel DirectLink
MergedId FETCHMERGED-LOGICAL-i175t-3b26e6af1fedea1b91babf47e70db273bd926c227946b5f77fbbc24b527a00ae3
PageCount 4
ParticipantIDs ieee_primary_8468928
PublicationCentury 2000
PublicationDate 2017-Dec.
PublicationDateYYYYMMDD 2017-12-01
PublicationDate_xml – month: 12
  year: 2017
  text: 2017-Dec.
PublicationDecade 2010
PublicationTitle 2017 IEEE International WIE Conference on Electrical and Computer Engineering (WIECON ECE)
PublicationTitleAbbrev WIECON-ECE
PublicationYear 2017
Publisher IEEE
Publisher_xml – name: IEEE
SSID ssj0002684826
Score 1.6848783
Snippet Due to a number of benefits, share of renewable energy based generation is increasing rapidly. However, intermittent behavior of renewable energy is...
SourceID ieee
SourceType Publisher
StartPage 96
SubjectTerms Batteries
Conferences
distributed generation
energy storage system
Frequency response
Generators
microgrid
Microgrids
Time-frequency analysis
Title Study of Frequency Response with Centralized vs. Distributed Placement of Battery Energy Storage Systems in Renewable Integrated Microgrid
URI https://ieeexplore.ieee.org/document/8468928
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV3LSsNAFB1qV65UWvHNLFyaNM-ZZF1TWqFS1GJ3ZR53JAip1FRoP8Gvdm6SVhQX7jKBzIR55D5yzrmEXFuLbhg30lF-Ck6kmD1zUWScACRXTEdSABKFx_dsOI3uZvGsRW52XBgAqMBn4OJl9S9fL9QKU2U9ayuTNEj2yJ7dZjVXa5dPQdUS6yo3EC7fS3vPI6wF6GT9DBFc3G2e_lFGpbIigwMy3o5fg0de3VUpXbX5Jc343xc8JN1vvh6d7CzREWlB0SGfCBFc04Whg2WNl17ThxoRCxTTr7TJ7OYb0PTj3aW3KKKL9a9se4LpdRwNO6hFONc0q4iC9NHG6fYzRBu1c5oXtmPrniMLi462-hOajhHs97LMdZdMB9lTf-g0lRec3LoTpRPKgAETxjegQfgy9aWQJuLAPS2twyN1GjCF4oMRk7HhdrGlCiIZB1x4noDwmLSLRQEnhIYouJiERsda2-hK2YBSgs8FU8wkgoenpIPzOH-rxTXmzRSe_X37nOzjWtZ4kgvSLpcruLReQSmvqu3wBaOMvBQ
linkProvider IEEE
linkToHtml http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV1NT8IwGG4QD3pSA8Zve_DoBtu6lp1xBJQRohC5kbV9a4gJGAQT-An-avtuA6Px4G1bsrZpt74ffZ7nJeTGWnTDhZGO8iJwmOL2n2PMOD5IobhmMgUkCic93h6y-1E4KpHbLRcGADLwGbh4mZ3l65laYqqsZm1lI_IbO2TX2n0W5mytbUYFdUuss1yAuLx6VHvuYDVAJ27GiOESbvH-j0IqmR1pHZBkM4IcPvLqLhfSVetf4oz_HeIhqX4z9mh_a4uOSAmmFfKJIMEVnRnamueI6RV9zDGxQDEBS4vc7mQNmn68u_QOZXSxApa972OCHXvDBnIZzhWNM6ogfbKRut2IaKF3TidT27B10JGHRTsbBQpNE4T7vcwnukqGrXjQbDtF7QVnYh2KhRNInwNPjWdAQ-rJyJOpNEyAqGtpXR6pI58rlB9kXIZG2OWWymcy9EVar6cQHJPydDaFE0IDlFxsBEaHWtv4StmQUoInUq64aaQiOCUVnMfxWy6vMS6m8Ozvx9dkrz1IuuNup_dwTvZxXXN0yQUpL-ZLuLQ-wkJeZZ_GF6PQv2E
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Abook&rft.genre=proceeding&rft.title=2017+IEEE+International+WIE+Conference+on+Electrical+and+Computer+Engineering+%28WIECON+ECE%29&rft.atitle=Study+of+Frequency+Response+with+Centralized+vs.+Distributed+Placement+of+Battery+Energy+Storage+Systems+in+Renewable+Integrated+Microgrid&rft.au=Arif%2C+Shaila&rft.au=Aziz%2C+Tareq&rft.date=2017-12-01&rft.pub=IEEE&rft.spage=96&rft.epage=99&rft_id=info:doi/10.1109%2FWIECON-ECE.2017.8468928&rft.externalDocID=8468928