Performance evaluation of ZigBee network for multi-patient cardiac monitoring in intra-hospital scenario
This paper presents performance analysis of ZigBee network in intra-hospital environment for multi-patient cardiac monitoring. A telemedicine scenario has been proposed where ECG signals of patients in Cardiac Care Unit (CCU) are being transmitted using ZigBee network. These signals are monitored co...
Saved in:
Published in | 2014 International Conference on Medical Imaging, m-Health and Emerging Communication Systems (MedCom) pp. 422 - 427 |
---|---|
Main Authors | , , , |
Format | Conference Proceeding |
Language | English |
Published |
IEEE
01.11.2014
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Abstract | This paper presents performance analysis of ZigBee network in intra-hospital environment for multi-patient cardiac monitoring. A telemedicine scenario has been proposed where ECG signals of patients in Cardiac Care Unit (CCU) are being transmitted using ZigBee network. These signals are monitored continuously at Nursing Station (NS) on compact handheld devices like Personal Digital Assistant (PDA). The low power and small size ZigBee devices have the ability to form self configuring networks (Ad-hoc network) that can extend themselves through a hospital network. Performance of the proposed Wireless Body Area Network (WBAN) is evaluated for various routing protocols by varying transmission power and simulation results are obtained in terms of throughput, end to end delay, packet delivery ratio, total power consumed and network lifetime. |
---|---|
AbstractList | This paper presents performance analysis of ZigBee network in intra-hospital environment for multi-patient cardiac monitoring. A telemedicine scenario has been proposed where ECG signals of patients in Cardiac Care Unit (CCU) are being transmitted using ZigBee network. These signals are monitored continuously at Nursing Station (NS) on compact handheld devices like Personal Digital Assistant (PDA). The low power and small size ZigBee devices have the ability to form self configuring networks (Ad-hoc network) that can extend themselves through a hospital network. Performance of the proposed Wireless Body Area Network (WBAN) is evaluated for various routing protocols by varying transmission power and simulation results are obtained in terms of throughput, end to end delay, packet delivery ratio, total power consumed and network lifetime. |
Author | Rashid, Tarique Kumar, Basant Kumar, Arvind Pathak, Shashwat |
Author_xml | – sequence: 1 givenname: Tarique surname: Rashid fullname: Rashid, Tarique organization: Dept. of Electron. & Commun. Eng., Motilal Nehru Nat. Inst. of Technol., Allahabad, India – sequence: 2 givenname: Basant surname: Kumar fullname: Kumar, Basant organization: Dept. of Electron. & Commun. Eng., Motilal Nehru Nat. Inst. of Technol., Allahabad, India – sequence: 3 givenname: Shashwat surname: Pathak fullname: Pathak, Shashwat organization: Dept. of Electron. & Commun. Eng., Motilal Nehru Nat. Inst. of Technol., Allahabad, India – sequence: 4 givenname: Arvind surname: Kumar fullname: Kumar, Arvind organization: Dept. of Electron. & Commun. Eng., Motilal Nehru Nat. Inst. of Technol., Allahabad, India |
BookMark | eNotj81KAzEUhSPoQmufoJu8wIxJJpNpllr8g4oudOOm3CY37cWZZEhTxbd3wMKBs_m-A-eKnccUkbGFFLWUwt68oF-loVZC6roTwgjdnrG57ZZSd9a2whpzyfZvmEPKA0SHHL-hP0KhFHkK_JN2d4g8YvlJ-YtPFB-OfaFqnBCMhTvInsDxIUUqKVPccYpTSoZqnw4jFej5wWGETOmaXQToDzg_9Yx9PNy_r56q9evj8-p2XZE0olTLTkktlEa_bYQNzVY65cEorVznQ9CqES4o37RaGeFsq_XWaLBeS9UqN0kztvjfJUTcjJkGyL-b0__mD-H7Vt0 |
ContentType | Conference Proceeding |
DBID | 6IE 6IL CBEJK RIE RIL |
DOI | 10.1109/MedCom.2014.7006045 |
DatabaseName | IEEE Electronic Library (IEL) Conference Proceedings IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume IEEE Xplore All Conference Proceedings IEEE Xplore IEEE Proceedings Order Plans (POP All) 1998-Present |
DatabaseTitleList | |
Database_xml | – sequence: 1 dbid: RIE name: IEEE Xplore url: https://proxy.k.utb.cz/login?url=https://ieeexplore.ieee.org/ sourceTypes: Publisher |
DeliveryMethod | fulltext_linktorsrc |
EISBN | 9781479950966 1479950963 1479950971 9781479950973 |
EndPage | 427 |
ExternalDocumentID | 7006045 |
Genre | orig-research |
GroupedDBID | 6IE 6IL CBEJK RIE RIL |
ID | FETCH-LOGICAL-i160t-87214024edb309f3b1c2da6242c7dff4230cf2d354260c9544b64a9d41252cdb3 |
IEDL.DBID | RIE |
IngestDate | Thu Jun 29 18:35:55 EDT 2023 |
IsPeerReviewed | false |
IsScholarly | false |
Language | English |
LinkModel | DirectLink |
MergedId | FETCHMERGED-LOGICAL-i160t-87214024edb309f3b1c2da6242c7dff4230cf2d354260c9544b64a9d41252cdb3 |
PageCount | 6 |
ParticipantIDs | ieee_primary_7006045 |
PublicationCentury | 2000 |
PublicationDate | 2014-Nov. |
PublicationDateYYYYMMDD | 2014-11-01 |
PublicationDate_xml | – month: 11 year: 2014 text: 2014-Nov. |
PublicationDecade | 2010 |
PublicationTitle | 2014 International Conference on Medical Imaging, m-Health and Emerging Communication Systems (MedCom) |
PublicationTitleAbbrev | MedCom |
PublicationYear | 2014 |
Publisher | IEEE |
Publisher_xml | – name: IEEE |
Score | 1.6055089 |
Snippet | This paper presents performance analysis of ZigBee network in intra-hospital environment for multi-patient cardiac monitoring. A telemedicine scenario has been... |
SourceID | ieee |
SourceType | Publisher |
StartPage | 422 |
SubjectTerms | Ad hoc networks AODV DYMO Electrocardiography LANMAR Routing Routing Protocol Routing protocols Sensors Telemedicine Wireless body area network (WBAN) Wireless communication Wireless sensor networks ZigBee |
Title | Performance evaluation of ZigBee network for multi-patient cardiac monitoring in intra-hospital scenario |
URI | https://ieeexplore.ieee.org/document/7006045 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV3PS8MwFA7bTp5UNvE3OXg0XZofbXdVHEOY7OBgeBlt8uKG2MroLv71vqR1Q_Eg9FBKQkpeX19e8n3fI-QGrQySCxNwfkyhA7EcTMxS5awutMks9-Tk6VMymavHhV50yO2OCwMAAXwGkb8NZ_m2Mlu_VTZMvXqI0l3SzbhouFqtkBAONJyCRR_yaC0VtS1_lEwJEWN8SKbfYzVAkbdoWxeR-fwlw_jflzkigz03j852UeeYdKDsk9Vsj_-newFvWjn6sn69A6BlA_em2IoGECFrFVWpCd-Ioe_Bu_02H12XeNWbnK3aqiLUaz5hVl0NyHz88Hw_YW0NBbaOE17jz05gCiUU2ELykZNFbITNPSnEpNY5XExx44SV2ivVm5FWqkhUPrIKFz7CYKcT0iurEk4JBZ-75UkGqbFK4trBZFyDk9g5l8rFZ6TvZ2n50chkLNsJOv_78QU58JZqaH2XpFdvtnCF8b0uroNhvwAXpKmp |
link.rule.ids | 310,311,786,790,795,796,802,27958,55109 |
linkProvider | IEEE |
linkToHtml | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV1NT4NAEJ3UetCTmtb47R48CuVjgXLV2FQtTQ9t0nhpYHfWNkYwDVz89c4u2EbjwYQDkN2w2WGYmeW9twA3ZGX0HU8YnJ_FyYGsFIVrRVzJIAtEXzqanJyMw-GMP82DeQtuN1wYRDTgM7T1qfmXLwtR6aWyXqTVQ3iwA7sU5524Zms1UkJ03UtQkhdpvBa3m7Y_Nk0xMWNwAMn302qoyJtdlZktPn8JMf53OIfQ3bLz2GQTd46ghXkHlpMtA4BtJbxZodjL6vUOkeU14JtRK2ZghFajqcqEeUsEezf-rRf62Cqno1yn1rLZV4Rp1Seqq4suzAYP0_uh1eyiYK3c0Cnpc-dREeVxlJnvxMrPXOHJVNNCRCSVonTKEcqTfqC16kUccJ6FPI0lp9THE9TpGNp5keMJMNTVWxr2MRKS-5Q9iL4ToPKpc-pz5Z5CR8_S4qMWylg0E3T29-1r2BtOk9Fi9Dh-Pod9bbWa5HcB7XJd4SVF-zK7Mkb-AjamrP8 |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Abook&rft.genre=proceeding&rft.title=2014+International+Conference+on+Medical+Imaging%2C+m-Health+and+Emerging+Communication+Systems+%28MedCom%29&rft.atitle=Performance+evaluation+of+ZigBee+network+for+multi-patient+cardiac+monitoring+in+intra-hospital+scenario&rft.au=Rashid%2C+Tarique&rft.au=Kumar%2C+Basant&rft.au=Pathak%2C+Shashwat&rft.au=Kumar%2C+Arvind&rft.date=2014-11-01&rft.pub=IEEE&rft.spage=422&rft.epage=427&rft_id=info:doi/10.1109%2FMedCom.2014.7006045&rft.externalDocID=7006045 |