Motion and noise artifact-resilient atrial fibrillation detection algorithm for a smartphone

We have developed a motion and noise artifact (MNA)-resilient atrial fibrillation (AF) detection algorithm for smartphones that eliminates MNAs, and then detects AFs in smartphone camera recordings. MNA-corrupted episodes are observed to have larger values of turning point ratio (TPR), pulse slope,...

Full description

Saved in:
Bibliographic Details
Published inIEEE journal of biomedical and health informatics pp. 591 - 594
Main Authors Chong, Jo Woon, Cho, Chae Ho, Esa, Nada, McManus, David D., Chon, Ki H.
Format Conference Proceeding Journal Article
LanguageEnglish
Published IEEE 01.02.2016
Subjects
Online AccessGet full text
ISSN2168-2208
DOI10.1109/BHI.2016.7455967

Cover

Loading…
Abstract We have developed a motion and noise artifact (MNA)-resilient atrial fibrillation (AF) detection algorithm for smartphones that eliminates MNAs, and then detects AFs in smartphone camera recordings. MNA-corrupted episodes are observed to have larger values of turning point ratio (TPR), pulse slope, or Kurtosis compared to clean AF and normal sinus rhythm (NSR) episodes. On the other hand, AFs are shown to have larger root mean square of successive RR differences (RMSSD) and Shannon Entropy (ShE) [1]. Our developed AF algorithm is capable of separating MNAs, NSRs, AFs, which enhances the specificity of AF detection. We have recruited 88 subjects having AF at baseline and NSR after electrical cardioversion, and 11 subjects having MNA-corrupted NSRs to evaluate the performance of our AF algorithm. The clinical tests show that the proposed AF algorithm gives higher accuracy, sensitivity and specificity of 0.9667, 0.9765, 0.9714 compared to the previous AF algorithm [1].
AbstractList We have developed a motion and noise artifact (MNA)-resilient atrial fibrillation (AF) detection algorithm for smartphones that eliminates MNAs, and then detects AFs in smartphone camera recordings. MNA-corrupted episodes are observed to have larger values of turning point ratio (TPR), pulse slope, or Kurtosis compared to clean AF and normal sinus rhythm (NSR) episodes. On the other hand, AFs are shown to have larger root mean square of successive RR differences (RMSSD) and Shannon Entropy (ShE) [1]. Our developed AF algorithm is capable of separating MNAs, NSRs, AFs, which enhances the specificity of AF detection. We have recruited 88 subjects having AF at baseline and NSR after electrical cardioversion, and 11 subjects having MNA-corrupted NSRs to evaluate the performance of our AF algorithm. The clinical tests show that the proposed AF algorithm gives higher accuracy, sensitivity and specificity of 0.9667, 0.9765, 0.9714 compared to the previous AF algorithm [1].
Author Chong, Jo Woon
McManus, David D.
Chon, Ki H.
Esa, Nada
Cho, Chae Ho
Author_xml – sequence: 1
  givenname: Jo Woon
  surname: Chong
  fullname: Chong, Jo Woon
  organization: Cardiologists, RockhamptonBase Hospital, Australia
– sequence: 2
  givenname: Chae Ho
  surname: Cho
  fullname: Cho, Chae Ho
  organization: Central Queensland University, Australia
– sequence: 3
  givenname: Nada
  surname: Esa
  fullname: Esa, Nada
  organization: Central Queensland University, Australia
– sequence: 4
  givenname: David D.
  surname: McManus
  fullname: McManus, David D.
  organization: Cardiologists, RockhamptonBase Hospital, Australia
– sequence: 5
  givenname: Ki H.
  surname: Chon
  fullname: Chon, Ki H.
  organization: Cardiologists, RockhamptonBase Hospital, Australia
BookMark eNqNULtOAzEQNAgkkpAeicYlzQU_7vwoIQISKYgGOqST725NjC52sJ2Cv8cifADbrHY0M5rZKTrzwQNCV5QsKCX69n61XjBCxULWTaOFPEFT2hBNWDnlKZowKlTFGFEXaJ7SJymjCqTFBL0_h-yCx8YP2AeXAJuYnTV9riIkNzrwGZscnRmxdV1042h-BQNk6I_S8SNEl7c7bEPEBqddsdhvS8RLdG7NmGD-t2fo7fHhdbmqNi9P6-XdpnK0EbliHRsGA8JAz4jQVGjRaQ7M1txaDrRmhshO2aFvrDWyG4hUbDA1VzWxSgCfoZuj7z6GrwOk3O5c6qFE9RAOqaWlLeENF-IfVKIEk0I2hXp9pDoAaPfRlV7f7d-L-Q-mpHJ_
ContentType Conference Proceeding
Journal Article
DBID 6IE
6IL
CBEJK
RIE
RIL
7QO
8FD
FR3
P64
7SC
7SP
7U5
F28
JQ2
L7M
L~C
L~D
DOI 10.1109/BHI.2016.7455967
DatabaseName IEEE Electronic Library (IEL) Conference Proceedings
IEEE Xplore POP ALL
IEEE Xplore All Conference Proceedings
IEEE Xplore
IEEE Proceedings Order Plans (POP All) 1998-Present
Biotechnology Research Abstracts
Technology Research Database
Engineering Research Database
Biotechnology and BioEngineering Abstracts
Computer and Information Systems Abstracts
Electronics & Communications Abstracts
Solid State and Superconductivity Abstracts
ANTE: Abstracts in New Technology & Engineering
ProQuest Computer Science Collection
Advanced Technologies Database with Aerospace
Computer and Information Systems Abstracts – Academic
Computer and Information Systems Abstracts Professional
DatabaseTitle Engineering Research Database
Biotechnology Research Abstracts
Technology Research Database
Biotechnology and BioEngineering Abstracts
Computer and Information Systems Abstracts – Academic
Electronics & Communications Abstracts
ProQuest Computer Science Collection
Computer and Information Systems Abstracts
Solid State and Superconductivity Abstracts
Advanced Technologies Database with Aerospace
ANTE: Abstracts in New Technology & Engineering
Computer and Information Systems Abstracts Professional
DatabaseTitleList
Technology Research Database
Engineering Research Database
Database_xml – sequence: 1
  dbid: RIE
  name: IEEE Xplore
  url: https://proxy.k.utb.cz/login?url=https://ieeexplore.ieee.org/
  sourceTypes: Publisher
DeliveryMethod fulltext_linktorsrc
Discipline Medicine
EISBN 1509024557
9781509024551
EISSN 2168-2208
EndPage 594
ExternalDocumentID 7455967
Genre orig-research
GroupedDBID 0R~
4.4
6IE
6IF
6IH
6IK
6IL
97E
AAJGR
AARMG
AASAJ
AAWTH
ABAZT
ABQJQ
ABVLG
ACIWK
ACPRK
AENEX
AFRAH
AGQYO
AGSQL
AHBIQ
AKJIK
AKQYR
ALMA_UNASSIGNED_HOLDINGS
BEFXN
BFFAM
BGNUA
BKEBE
BPEOZ
CBEJK
EBS
EJD
HZ~
IFIPE
IPLJI
JAVBF
M43
O9-
OCL
PQQKQ
RIA
RIE
RIL
RNS
7QO
8FD
FR3
P64
RIG
7SC
7SP
7U5
F28
JQ2
L7M
L~C
L~D
ID FETCH-LOGICAL-i156t-2b2ddae6aec20691696b93e2f43ff3e142a07b8fdc5ffa7bd0782da43840f86e3
IEDL.DBID RIE
IngestDate Fri Jul 11 16:35:42 EDT 2025
Fri Jul 11 09:06:50 EDT 2025
Wed Aug 27 02:36:11 EDT 2025
IsPeerReviewed true
IsScholarly true
Language English
LinkModel DirectLink
MergedId FETCHMERGED-LOGICAL-i156t-2b2ddae6aec20691696b93e2f43ff3e142a07b8fdc5ffa7bd0782da43840f86e3
Notes ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Conference-1
ObjectType-Feature-3
content type line 23
SourceType-Conference Papers & Proceedings-2
PQID 1808627675
PQPubID 23462
PageCount 4
ParticipantIDs proquest_miscellaneous_1808627675
ieee_primary_7455967
proquest_miscellaneous_1816035366
PublicationCentury 2000
PublicationDate 20160201
PublicationDateYYYYMMDD 2016-02-01
PublicationDate_xml – month: 02
  year: 2016
  text: 20160201
  day: 01
PublicationDecade 2010
PublicationTitle IEEE journal of biomedical and health informatics
PublicationTitleAbbrev BHI
PublicationYear 2016
Publisher IEEE
Publisher_xml – name: IEEE
SSID ssj0000816896
Score 1.9771836
Snippet We have developed a motion and noise artifact (MNA)-resilient atrial fibrillation (AF) detection algorithm for smartphones that eliminates MNAs, and then...
SourceID proquest
ieee
SourceType Aggregation Database
Publisher
StartPage 591
SubjectTerms Algorithms
Atrial fibrillation
Cameras
Detection algorithms
Fibrillation
Health
Lenses
Noise
Recording
Slopes
Smart phones
Smartphones
Support vector machines
Turning
Title Motion and noise artifact-resilient atrial fibrillation detection algorithm for a smartphone
URI https://ieeexplore.ieee.org/document/7455967
https://www.proquest.com/docview/1808627675
https://www.proquest.com/docview/1816035366
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV1LS8QwEA67exBPPnbFNxE82m6faXtVXFah4sGFPQglaSZa3G1lt73468203Qoq4q2HZgjJkMxkvm8-Qi5VKmyXKzC0L0WGx5zAiJjNDCdUANg9xOXId44f2HTm3c_9eY9cdVwYAKjBZ2DiZ13Ll0Va4VPZOPB0_MuCPunrxK3hanXvKbWARNRVIq1ofD29Q-gWM9thrX7Kj0O3vkkmOyTezKEBkLyZVSnM9ONbe8b_TnKXjL44e_Sxu432SA_yfbIVt6XzIXmOa70eynNJ8yJbA0WnQV6DoTPubIG8SMprEQ-qkAewaFByVEJZw7X00MVLscrK1yXVkS7ldL3UJhDbDiMym9w-3UyNVlrByHTCVhqOcKTkwDikjsV0iBgxEbngKM9VygXbc7gViFDJ1FeKB0JiJCG55-p8UIUM3AMyyLX5Q0ItHiiFyjCRDD0uVeT4XEd1SqW29C1bHJEhLlLy3nTPSNr1OSIXm21ItEdjmYLnUFTrxA4xzcImM3_9g_LYvsvY8e_mT8g27n2Drz4lg3JVwZkOH0pxXvvNJ3hHx7s
linkProvider IEEE
linkToHtml http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV1LS8NAEB5qBfXkoxXrcwWPpua5Sa6K0mpTPFjoQQib7KwW21Ta9OKvdydJK6iItxyyw7IZMjM73zcfwIVKE8sRCg3tS6Hhcts3Qm5xww4UIk0PcQTxnaM-7wzc-6E3rMHliguDiAX4DNv0WPTy5TRd0FXZle_q_Jf7a7Cu475nlWyt1Y1KISERrnqRZnh13ekSeIu3q4WVgsqP324RS-62IVruooSQvLUXedJOP74NaPzvNneg-cXaY4-reLQLNcz2YCOqmucNeI4KxR4mMsmy6WiOjNyGmA2GrrlHY2JGMlHIeDBFTIBxiZNjEvMCsKWXjl-ms1H-OmE612WCzSfaBKHbsQmDu9unm45RiSsYI12y5Yad2FIK5AJT2-Q6SQx5EjpoK9dRykHLtYXpJ4GSqaeU8BNJuYQUrqMrQhVwdPahnmnzB8BM4StF2jChDFwhVWh7Qud1SqWW9EwraUGDDil-L-dnxNX5tOB8-Rli7dPUqBAZThfz2Aqo0KIxM3-9QwLZnsP54e_mz2Cz8xT14l63_3AEW-QHJdr6GOr5bIEnOpnIk9PChz4BCbrLBA
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=proceeding&rft.title=IEEE+journal+of+biomedical+and+health+informatics&rft.atitle=Motion+and+noise+artifact-resilient+atrial+fibrillation+detection+algorithm+for+a+smartphone&rft.au=Chong%2C+Jo+Woon&rft.au=Cho%2C+Chae+Ho&rft.au=Esa%2C+Nada&rft.au=McManus%2C+David+D.&rft.date=2016-02-01&rft.pub=IEEE&rft.eissn=2168-2208&rft.spage=591&rft.epage=594&rft_id=info:doi/10.1109%2FBHI.2016.7455967&rft.externalDocID=7455967