Robust beat detection on noisy differential ECG

The differential ECG measurement is performed by a small gadget attached to a person's chest. In contrast to the standard 12-channel ECG, which is most often short and measured on a resting subject, the small form factor of the gadget allows for several days long measurement of active subjects....

Full description

Saved in:
Bibliographic Details
Published in2016 39th International Convention on Information and Communication Technology, Electronics and Microelectronics (MIPRO) pp. 381 - 386
Main Authors Lavric, Primoz, Depolli, Matjaz
Format Conference Proceeding
LanguageEnglish
Published Croatian Society MIPRO 01.05.2016
Subjects
Online AccessGet full text

Cover

Loading…
Abstract The differential ECG measurement is performed by a small gadget attached to a person's chest. In contrast to the standard 12-channel ECG, which is most often short and measured on a resting subject, the small form factor of the gadget allows for several days long measurement of active subjects. The resulting measurements are not only novel in their time and activity coverage, but they also require novel approach to their analysis. First, ECGs are noisier because the electrodes are placed close together and because measurements are made on physically active subjects. Second, the gadget is not always placed on by a trained professional and can be miss-oriented, producing a wide range of ECG orientations. Finally, the ECGs are measured with low sample ratio which helps conserve battery life of the gadget. In this work, we try to develop the first stage of such differential ECG analysis - algorithms for noise estimation and for beat detection. These novel algorithms have to be able to deal with noisy and sparsely sampled ECGs and with various beat shapes. Furthermore, these algorithms should be able to run in real-time applied to the ongoing measurement and on a very computationally weak portable devices, while maintaining power efficiency. Two algorithms for noise estimation and one for beat detection that fulfill those constraints are presented in this work.
AbstractList The differential ECG measurement is performed by a small gadget attached to a person's chest. In contrast to the standard 12-channel ECG, which is most often short and measured on a resting subject, the small form factor of the gadget allows for several days long measurement of active subjects. The resulting measurements are not only novel in their time and activity coverage, but they also require novel approach to their analysis. First, ECGs are noisier because the electrodes are placed close together and because measurements are made on physically active subjects. Second, the gadget is not always placed on by a trained professional and can be miss-oriented, producing a wide range of ECG orientations. Finally, the ECGs are measured with low sample ratio which helps conserve battery life of the gadget. In this work, we try to develop the first stage of such differential ECG analysis - algorithms for noise estimation and for beat detection. These novel algorithms have to be able to deal with noisy and sparsely sampled ECGs and with various beat shapes. Furthermore, these algorithms should be able to run in real-time applied to the ongoing measurement and on a very computationally weak portable devices, while maintaining power efficiency. Two algorithms for noise estimation and one for beat detection that fulfill those constraints are presented in this work.
Author Lavric, Primoz
Depolli, Matjaz
Author_xml – sequence: 1
  givenname: Primoz
  surname: Lavric
  fullname: Lavric, Primoz
  email: pl9506@student.uni-lj.si
  organization: Dept. of Commun. Syst., Jozef Stefan Insitute, Ljubljana, Slovenia
– sequence: 2
  givenname: Matjaz
  surname: Depolli
  fullname: Depolli, Matjaz
  email: matjaz.depolli@ijs.si
  organization: Dept. of Commun. Syst., Jozef Stefan Insitute, Ljubljana, Slovenia
BookMark eNotj8FKAzEUACPowVZ_QC_5gd3mvezLbo6y1FpoqRQ9l2TzAoGald146N8rWBiY28AsxG0eMwvxBKoGUHa1374fDzUqMHVLiNDijVhY0qi16oy6F6vj6H_mIj27IgMXHkoas_wjj2m-yJBi5IlzSe4s1_3mQdxFd5758eql-Hxdf_Rv1e6w2fYvuyoB6lJZNpo92E4PaFwgb7UxBJEsddRwdENowgABCCM6G9qI0QeiBkhZ5VgvxfN_NzHz6XtKX266nK4P-hcatD_H
ContentType Conference Proceeding
DBID 6IE
6IL
CBEJK
RIE
RIL
DOI 10.1109/MIPRO.2016.7522172
DatabaseName IEEE Electronic Library (IEL) Conference Proceedings
IEEE Xplore POP ALL
IEEE Xplore All Conference Proceedings
IEEE Electronic Library (IEL)
IEEE Proceedings Order Plans (POP All) 1998-Present
DatabaseTitleList
Database_xml – sequence: 1
  dbid: RIE
  name: IEEE/IET Electronic Library
  url: https://proxy.k.utb.cz/login?url=https://ieeexplore.ieee.org/
  sourceTypes: Publisher
DeliveryMethod fulltext_linktorsrc
EISBN 9532330860
9789532330885
9789532330861
9532330887
EndPage 386
ExternalDocumentID 7522172
Genre orig-research
GroupedDBID 6IE
6IL
CBEJK
RIE
RIL
ID FETCH-LOGICAL-i123t-9e63eb1983c26ad5b936651f595854efacd4dc1d152f2a9d7f2fbd55415090ae3
IEDL.DBID RIE
IngestDate Thu Jun 29 18:37:34 EDT 2023
IsPeerReviewed false
IsScholarly false
Language English
LinkModel DirectLink
MergedId FETCHMERGED-LOGICAL-i123t-9e63eb1983c26ad5b936651f595854efacd4dc1d152f2a9d7f2fbd55415090ae3
PageCount 6
ParticipantIDs ieee_primary_7522172
PublicationCentury 2000
PublicationDate 20160501
PublicationDateYYYYMMDD 2016-05-01
PublicationDate_xml – month: 05
  year: 2016
  text: 20160501
  day: 01
PublicationDecade 2010
PublicationTitle 2016 39th International Convention on Information and Communication Technology, Electronics and Microelectronics (MIPRO)
PublicationTitleAbbrev MIPRO
PublicationYear 2016
Publisher Croatian Society MIPRO
Publisher_xml – name: Croatian Society MIPRO
Score 1.616541
Snippet The differential ECG measurement is performed by a small gadget attached to a person's chest. In contrast to the standard 12-channel ECG, which is most often...
SourceID ieee
SourceType Publisher
StartPage 381
SubjectTerms Algorithm design and analysis
Complexity theory
Detection algorithms
Electrocardiography
Estimation
Noise measurement
Smoothing methods
Title Robust beat detection on noisy differential ECG
URI https://ieeexplore.ieee.org/document/7522172
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV3PS8MwFH5sO3lS2cTf5ODRdGmbZM15bE5hOoaD3UbSJDCUVlx70L_e13abKB6EHEII5Bcv30vyfXkAN4kwTBkbUuEjSbmKOUWccTTiiUXTUglPKu3w9FFOFvxhKZYtuN1rYZxzNfnMBVW2fsu3eVpWV2X9AToLCLhtaOPBrdFq7XQwTPWn97P5U0XWksG24o-IKTVgjA9humuq4Ym8BGVhgvTz1y-M_-3LEfS-pXlktgedY2i5rAv9eW7KTUEMbqzEuqKmV2UEU5avNx9kFwUFrfmVjIZ3PViMR8_DCd1GQqBrRJaCKidj3FRVEqeR1FYYFUspQi8UevvceZ1abtPQIhj7SCs78JE3Fj0FdPcU0y4-gU6WZ-4UiDWpFwnzcegsZ9prJblhRgptrDKanUG3GuzqrfnsYrUd5_nfxRdwUE14wwC8hE7xXrorROnCXNfL8wXkBpNR
linkProvider IEEE
linkToHtml http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV1LSwMxEB5qPehJpRXf7sGju91Hkm7OpbXVbi2lhd5KskmgKLtidw_66519tKJ4EHIIIZBMQvINyffNANyFVLpcKs-mxmc24QGxEWe07ZNQ4dHiIQkL7XA0YcMFeVzSZQPud1oYrXVJPtNOUS3_8lUa58VTWaeLzgIC7h7sI-5Tv1JrbZUwLu9Eo-nsuaBrMafu-iNnSgkZgyOItoNVTJEXJ8-kE3_-isP439kcQ_tbnGdNd7BzAg2dtKAzS2W-ySyJV6uldFYSrBILS5KuNx_WNg8KnudXq997aMNi0J_3hnadC8FeI7ZkNtcswGuVh0HsM6Go5AFj1DOUo79PtBGxIir2FMKx8QVXXeMbqdBXQIePu0IHp9BM0kSfgaVkbGjomsDTirjCCM6IdCWjQiouhXsOrcLY1VsV7mJV23nxd_MtHAzn0Xg1Hk2eLuGwWPyKD3gFzew919eI2Zm8KbfqC8dtlps
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Abook&rft.genre=proceeding&rft.title=2016+39th+International+Convention+on+Information+and+Communication+Technology%2C+Electronics+and+Microelectronics+%28MIPRO%29&rft.atitle=Robust+beat+detection+on+noisy+differential+ECG&rft.au=Lavric%2C+Primoz&rft.au=Depolli%2C+Matjaz&rft.date=2016-05-01&rft.pub=Croatian+Society+MIPRO&rft.spage=381&rft.epage=386&rft_id=info:doi/10.1109%2FMIPRO.2016.7522172&rft.externalDocID=7522172