Chest-worn Transmitarray Lens for Monitoring Heart Rate Variability with a Remote Self-Injection-Locked Doppler Radar

This paper presents a transmitarray lens that can be worn on the chest to focus the radar beam towards a specific area of the heart for monitoring heart rate variability (HRV). The used Doppler radar is based on self-injection-locking (SIL) technology and was placed remotely from the monitored subje...

Full description

Saved in:
Bibliographic Details
Published inIEEE MTT-S International Microwave Symposium digest pp. 1188 - 1191
Main Authors El Arif, Rezki, Su, Wei-Chih, Horng, Tzyy-Sheng, Wu, Chung-Tse Michael
Format Conference Proceeding
LanguageEnglish
Published IEEE 11.06.2023
Subjects
Online AccessGet full text
ISSN2576-7216
DOI10.1109/IMS37964.2023.10188195

Cover

Loading…
Abstract This paper presents a transmitarray lens that can be worn on the chest to focus the radar beam towards a specific area of the heart for monitoring heart rate variability (HRV). The used Doppler radar is based on self-injection-locking (SIL) technology and was placed remotely from the monitored subject. In the experiment, the transmitarray lens was set up to concentrate the incident wave penetrating into the chest on the heart's tricuspid valve; thus, the accuracy of monitoring HRV can be greatly improved. The comparison of the interbeat interval (IBI) data between the proposed radar measurement and the conventional electrocardiogram (ECG) shows excellent agreement.
AbstractList This paper presents a transmitarray lens that can be worn on the chest to focus the radar beam towards a specific area of the heart for monitoring heart rate variability (HRV). The used Doppler radar is based on self-injection-locking (SIL) technology and was placed remotely from the monitored subject. In the experiment, the transmitarray lens was set up to concentrate the incident wave penetrating into the chest on the heart's tricuspid valve; thus, the accuracy of monitoring HRV can be greatly improved. The comparison of the interbeat interval (IBI) data between the proposed radar measurement and the conventional electrocardiogram (ECG) shows excellent agreement.
Author El Arif, Rezki
Su, Wei-Chih
Horng, Tzyy-Sheng
Wu, Chung-Tse Michael
Author_xml – sequence: 1
  givenname: Rezki
  surname: El Arif
  fullname: El Arif, Rezki
  organization: National Sun Yat-Sen University,Department of Electrical Engineering,Kaohsiung,Taiwan
– sequence: 2
  givenname: Wei-Chih
  surname: Su
  fullname: Su, Wei-Chih
  organization: National Sun Yat-Sen University,Department of Electrical Engineering,Kaohsiung,Taiwan
– sequence: 3
  givenname: Tzyy-Sheng
  surname: Horng
  fullname: Horng, Tzyy-Sheng
  organization: National Sun Yat-Sen University,Department of Electrical Engineering,Kaohsiung,Taiwan
– sequence: 4
  givenname: Chung-Tse Michael
  surname: Wu
  fullname: Wu, Chung-Tse Michael
  organization: Rutgers University,Department of Electrical and Computer Engineering,New Jersey,USA
BookMark eNo1kN9KwzAchaMouM29gUheIDNp2qS5lPlngw5hm96ONP3FZXbJSCOjb29BvToXh_PBd8boygcPCN0zOmOMqoflasOlEvksoxmfMcrKkqniAk2VVCUvKM-lyOUlGmWFFERmTNygcdcdKKVFycQIfc_30CVyDtHjbdS-O7qkY9Q9rsB32IaIV8G7FKLzn3gBOia81gnwh45O1651qcdnl_ZY4zUcw9BsoLVk6Q9gkgueVMF8QYOfwunUQhzGjY636NrqtoPpX07Q-8vzdr4g1dvrcv5YEceYSkQxo4yp60YbxrkQJYimlrUAqqi1VoPKmsHbghj0NBiRq4KCkA2raU1pzifo7pfrAGB3iu6oY7_7v4n_APU_YHo
ContentType Conference Proceeding
DBID 6IE
6IH
CBEJK
RIE
RIO
DOI 10.1109/IMS37964.2023.10188195
DatabaseName IEEE Electronic Library (IEL) Conference Proceedings
IEEE Proceedings Order Plan (POP) 1998-present by volume
IEEE Xplore All Conference Proceedings
IEEE Electronic Library (IEL)
IEEE Proceedings Order Plans (POP) 1998-present
DatabaseTitleList
Database_xml – sequence: 1
  dbid: RIE
  name: IEEE Electronic Library (IEL)
  url: https://proxy.k.utb.cz/login?url=https://ieeexplore.ieee.org/
  sourceTypes: Publisher
DeliveryMethod fulltext_linktorsrc
Discipline Engineering
EISBN 9798350347647
EISSN 2576-7216
EndPage 1191
ExternalDocumentID 10188195
Genre orig-research
GrantInformation_xml – fundername: National Science and Technology Council
  funderid: 10.13039/501100020950
GroupedDBID -~X
6IE
6IF
6IH
6IK
6IL
6IM
6IN
AAJGR
AAWTH
ABPPZ
ACGFS
ADZIZ
ALMA_UNASSIGNED_HOLDINGS
BEFXN
BFFAM
BGNUA
BKEBE
BPEOZ
CBEJK
CHZPO
IPLJI
M43
OCL
RIE
RIL
RIO
ID FETCH-LOGICAL-i119t-91c9ccbbdac133668e6db7b6e090fffae92d023fe6257aec64950e67d1b0b0043
IEDL.DBID RIE
IngestDate Wed Aug 27 02:20:25 EDT 2025
IsPeerReviewed false
IsScholarly true
Language English
LinkModel DirectLink
MergedId FETCHMERGED-LOGICAL-i119t-91c9ccbbdac133668e6db7b6e090fffae92d023fe6257aec64950e67d1b0b0043
PageCount 4
ParticipantIDs ieee_primary_10188195
PublicationCentury 2000
PublicationDate 2023-June-11
PublicationDateYYYYMMDD 2023-06-11
PublicationDate_xml – month: 06
  year: 2023
  text: 2023-June-11
  day: 11
PublicationDecade 2020
PublicationTitle IEEE MTT-S International Microwave Symposium digest
PublicationTitleAbbrev IMS
PublicationYear 2023
Publisher IEEE
Publisher_xml – name: IEEE
SSID ssj0005816
Score 2.222722
Snippet This paper presents a transmitarray lens that can be worn on the chest to focus the radar beam towards a specific area of the heart for monitoring heart rate...
SourceID ieee
SourceType Publisher
StartPage 1188
SubjectTerms Doppler radar
Heart rate variability
Microwave devices
Microwave theory and techniques
Radar detection
Radar measurements
self-injection-locking
Three-dimensional printing
transmitarray lens
wearable device
Title Chest-worn Transmitarray Lens for Monitoring Heart Rate Variability with a Remote Self-Injection-Locked Doppler Radar
URI https://ieeexplore.ieee.org/document/10188195
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV1La8MwDDZrT9tlr4698WFXp3GbOM65W2lHW0a7jt6KHwp0j2SElNH9-slJuxcMdgshxkGWLH22PomQq3aUCG6igAltExYAD5gECFmr5Sp_iFD5keM7D0eiNw1uZ-FsTVYvuTAAUCafgecey7t8m5mlOypruupS7t6nRmqI3Cqy1lc-h-RiTQHmftzsDydtR7P0XH9wbzPyRw-V0oV0d8loM3mVOfLkLQvtmfdfdRn__Xd7pPHF1qN3n35on2xBekB2vhUaPCTLjmuLxd6yPKWld3pZFCrP1YoOEMZSDFxpZdzuc9pD7S_oGKNQ-oBQuqrkvaLuyJYqOgZcXaATeE5YP30sU7lSNsB9FSy9zjCqhRwHW5U3yLR7c9_psXXDBbbgPC5w4zOxMVpbZRC6CiFBWB1pAX7sJ0miIG5ZlGYCCJoiBUYguvJBRJZr35l_-4jU0yyFY0L9QIVSSIsmjwBQGanD0EpjUAUAvaU8IQ0nwflrVVNjvhHe6R_vz8i2W0iXpMX5OakX-RIuMBwo9GWpBh9DGLXD
linkProvider IEEE
linkToHtml http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV1LT8MwDI5gHIALryHe5MA1XbO1aXseTBtsE9oD7Tbl4Urj0aKqExq_HqfdeElI3KqqUSrHsf0l_mxCrhpBLLgOPCaUiZkH3GMhgM_qdVv5Q_jSDSzfudcX7bF3O_EnS7J6wYUBgCL5DBz7WNzlm1TP7VFZzVaXsvc-62QDHb8XlXStr4yOkIslCZi7Ua3TGzYs0dKxHcKd1dgfXVQKJ9LaIf3V9GXuyJMzz5Wj339VZvz3_-2S6hdfj95_eqI9sgbJPtn-VmrwgMybtjEWe0uzhBb-6WWWyyyTC9pFIEsxdKXl9raf0zbqf04HGIfSBwTTZS3vBbWHtlTSAeD6Ah3Cc8w6yWORzJWwLlpWMPQ6xbgWMhxsZFYl49bNqNlmy5YLbMZ5lKPp05HWShmpEbwKEYIwKlAC3MiN41hCVDcozRgQNgUStEB85YIIDFeuNQCNQ1JJ0gSOCHU96YciNLjpEQJKHSrfN6HWqASA_jI8JlUrwelrWVVjuhLeyR_vL8lme9TrTrud_t0p2bKLalO2OD8jlTybwzkGB7m6KFTiA_kVuRM
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Abook&rft.genre=proceeding&rft.title=IEEE+MTT-S+International+Microwave+Symposium+digest&rft.atitle=Chest-worn+Transmitarray+Lens+for+Monitoring+Heart+Rate+Variability+with+a+Remote+Self-Injection-Locked+Doppler+Radar&rft.au=El+Arif%2C+Rezki&rft.au=Su%2C+Wei-Chih&rft.au=Horng%2C+Tzyy-Sheng&rft.au=Wu%2C+Chung-Tse+Michael&rft.date=2023-06-11&rft.pub=IEEE&rft.eissn=2576-7216&rft.spage=1188&rft.epage=1191&rft_id=info:doi/10.1109%2FIMS37964.2023.10188195&rft.externalDocID=10188195