Errors due to sampling frequency of the electrocardiogram in spectral analysis of heart rate signals with low variability
Spectral analysis of the heart rate signal was studied in patients with low heart rate variability regarding an error that may occur when there is a specific relation between the averaged heart rate and the sampling frequency of the electrocardiogram. ECG waveforms were recorded from healthy subject...
Saved in:
Published in | 1995 Computers in Cardiology pp. 461 - 463 |
---|---|
Main Authors | , |
Format | Conference Proceeding |
Language | English |
Published |
IEEE
1995
|
Subjects | |
Online Access | Get full text |
ISBN | 9780780330535 0780330536 |
DOI | 10.1109/CIC.1995.482685 |
Cover
Loading…
Abstract | Spectral analysis of the heart rate signal was studied in patients with low heart rate variability regarding an error that may occur when there is a specific relation between the averaged heart rate and the sampling frequency of the electrocardiogram. ECG waveforms were recorded from healthy subjects and from patients after heart transplant, digitized with different sampling rates and analyzed for spectral analysis of heart rate variability. It was found that in healthy subjects with high heart rate variability, accurate results can be obtained when the sampling rate of the ECG is greater than 125 Hz. In heart transplant patients, up to 100% error may occur when the sampling rate is below 1 kHz. It is concluded that for spectral analysis of the heart rate signal recorded from patients that are characterized with low heart rate variability, high sampling rate of the ECG signal is necessary (1 kHz). |
---|---|
AbstractList | Spectral analysis of the heart rate signal was studied in patients with low heart rate variability regarding an error that may occur when there is a specific relation between the averaged heart rate and the sampling frequency of the electrocardiogram. ECG waveforms were recorded from healthy subjects and from patients after heart transplant, digitized with different sampling rates and analyzed for spectral analysis of heart rate variability. It was found that in healthy subjects with high heart rate variability, accurate results can be obtained when the sampling rate of the ECG is greater than 125 Hz. In heart transplant patients, up to 100% error may occur when the sampling rate is below 1 kHz. It is concluded that for spectral analysis of the heart rate signal recorded from patients that are characterized with low heart rate variability, high sampling rate of the ECG signal is necessary (1 kHz). |
Author | Abboud, S. Barnea, O. |
Author_xml | – sequence: 1 givenname: S. surname: Abboud fullname: Abboud, S. organization: Dept. of Biomed. Eng., Tel Aviv Univ., Israel – sequence: 2 givenname: O. surname: Barnea fullname: Barnea, O. organization: Dept. of Biomed. Eng., Tel Aviv Univ., Israel |
BookMark | eNotkEFLAzEQhQMqqLVnwdP8gdZks0mToyxVCwUvei6z2dk2st3UJLXsv3dLfTwYeN9jDu-eXfehJ8YeBZ8Lwe1ztarmwlo1L02hjbpiU7swfLSUXEl1y6YpffNRShlR6js2LGMMMUFzJMgBEu4Pne-30Eb6OVLvBggt5B0BdeRyDA5j48M24h58D-lwDrED7LEbkk_n9o4wZoiYCZLfjiDByecddOEEvxg91r7zeXhgN-3IaPp_J-zrdflZvc_WH2-r6mU984KXeYa6kehqWXPVYqOMbJWzRpNxhnRrlTbGjaBYiBZrUZdcy9IK4XhBojC6kBP2dPnriWhziH6Pcdhc9pF_9DZfgg |
ContentType | Conference Proceeding |
DBID | 6IE 6IL CBEJK RIE RIL |
DOI | 10.1109/CIC.1995.482685 |
DatabaseName | IEEE Electronic Library (IEL) Conference Proceedings IEEE Xplore POP ALL IEEE Xplore All Conference Proceedings IEEE Electronic Library (IEL) IEEE Proceedings Order Plans (POP All) 1998-Present |
DatabaseTitleList | |
Database_xml | – sequence: 1 dbid: RIE name: IEEE Electronic Library (IEL) url: https://proxy.k.utb.cz/login?url=https://ieeexplore.ieee.org/ sourceTypes: Publisher |
DeliveryMethod | fulltext_linktorsrc |
EndPage | 463 |
ExternalDocumentID | 482685 |
Genre | orig-research |
GroupedDBID | 6IE 6IK 6IL AAJGR AAWTH ACGHX ALMA_UNASSIGNED_HOLDINGS BEFXN BFFAM BGNUA BKEBE BPEOZ CBEJK OCL RIE RIL |
ID | FETCH-LOGICAL-i104t-a6d3acb3b05fad583f5c986e8c8e6f95688cfad271fab1b40634911c02e128623 |
IEDL.DBID | RIE |
ISBN | 9780780330535 0780330536 |
IngestDate | Tue Aug 26 21:34:34 EDT 2025 |
IsPeerReviewed | false |
IsScholarly | false |
Language | English |
LinkModel | DirectLink |
MergedId | FETCHMERGED-LOGICAL-i104t-a6d3acb3b05fad583f5c986e8c8e6f95688cfad271fab1b40634911c02e128623 |
PageCount | 3 |
ParticipantIDs | ieee_primary_482685 |
PublicationCentury | 1900 |
PublicationDate | 19950000 |
PublicationDateYYYYMMDD | 1995-01-01 |
PublicationDate_xml | – year: 1995 text: 19950000 |
PublicationDecade | 1990 |
PublicationTitle | 1995 Computers in Cardiology |
PublicationTitleAbbrev | CIC |
PublicationYear | 1995 |
Publisher | IEEE |
Publisher_xml | – name: IEEE |
SSID | ssj0000558146 |
Score | 1.2535927 |
Snippet | Spectral analysis of the heart rate signal was studied in patients with low heart rate variability regarding an error that may occur when there is a specific... |
SourceID | ieee |
SourceType | Publisher |
StartPage | 461 |
SubjectTerms | Analytical models Electrocardiography Fluctuations Frequency Heart rate Heart rate variability Sampling methods Signal analysis Signal processing Spectral analysis |
Title | Errors due to sampling frequency of the electrocardiogram in spectral analysis of heart rate signals with low variability |
URI | https://ieeexplore.ieee.org/document/482685 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV3LSsNAFB1sV658VXxzF27T5jXJZF1aqqC4sNBdmZnMSLEkkiZK_XrvnURFceEqT0IYhsy5J-ecy9i1tGGmsiD0rIiIusFyR8o49hL8LoQccZJVROjf3SezeXy74IsuZ9t5YYwxTnxmhrTr_uXnpW6IKhvFiIUF77EezrLWqvVFp_icE5nlCnPhY5HOo6TL1_k85l2yT-Bno_HNmHx6fNg-8kdrFbeyTPday_bGBRKSoOR52NRqqN9_xTX-86X32eDbwgcPX4vTAdsxxRHbTqqqrDaQNwbqEjaS5OTFE9iqFVRvobSAiBC65jjaiVVJvwWrApwps5JrkF2QCd1NDbFroLwJICkITmYgahfW5Ru8Yh3exoBvB2w-nTyOZ17Xe8FbYYFWezLJI6lVpHxuZc5FZLnORGKEFiax5DEUGi-EaWClChTCgijG76b2Q4MrHmKqY9YvysKcMEhUoJPUz9NMpnGscRPpUJgwTU2AcFCdskMateVLG6-xbAfs7M-z52y39ZQTB3LB-nXVmEtEBbW6cvPhA3eFtjw |
linkProvider | IEEE |
linkToHtml | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV3JTsMwELVYDnBiK2JnDlzTZnPinKuiFlrEASRule3YCIESlKag8vXMOKEIxIFTVkWRZXnejN97w9iFtGGmsiD0rIiodIPpjpRx7CW4LoQccZJVVNCf3CTD-_jqgT-0PttOC2OMceQz06VTt5efl3pOpbJejFhY8FW2jmE_5o1Ya1lQ8TmncpZLzYWPaTqPktZh5-uat94-gZ_1-qM-KfV4t_noj-YqLrZcbjWi7ZmzJCRKyXN3Xquu_vhl2PjP395mnW8RH9wuw9MOWzHFHlsMqqqsZpDPDdQlzCQRyotHsFVDqV5AaQExIbTtcbSjqxKDC54KcLLMSr6AbK1M6G1qiV0DOU4AkUFwOgMVd-GlfIc3zMQbI_BFh91fDu76Q6_tvuA9YYpWezLJI6lVpHxuZc5FZLnORGKEFiaxpDIUGh-EaWClChQCgyjGlVP7ocGYh6hqn60VZWEOGCQq0Enq52km0zjWeIh0KEyYpiZAQKgO2S6N2vS1MdiYNgN29Ofdc7YxvJuMp-PRzfUx22wU5lQROWFrdTU3p4gRanXm5sYnL2a5iQ |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Abook&rft.genre=proceeding&rft.title=1995+Computers+in+Cardiology&rft.atitle=Errors+due+to+sampling+frequency+of+the+electrocardiogram+in+spectral+analysis+of+heart+rate+signals+with+low+variability&rft.au=Abboud%2C+S.&rft.au=Barnea%2C+O.&rft.date=1995-01-01&rft.pub=IEEE&rft.isbn=9780780330535&rft.spage=461&rft.epage=463&rft_id=info:doi/10.1109%2FCIC.1995.482685&rft.externalDocID=482685 |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=9780780330535/lc.gif&client=summon&freeimage=true |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=9780780330535/mc.gif&client=summon&freeimage=true |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=9780780330535/sc.gif&client=summon&freeimage=true |