Study of human precorneal tear film thickness and structure using laser interferometry
The authors previously found that measurements of precorneal tear film thickness in animals, using laser interferometry and confocal microscopy, were larger than earlier estimates. They proposed that this occurred because optical methods did not disturb film structure and measured full thickness, in...
Saved in:
Published in | Investigative ophthalmology & visual science Vol. 33; no. 6; pp. 2006 - 2011 |
---|---|
Main Authors | , , , |
Format | Journal Article |
Language | English |
Published |
Rockville, MD
ARVO
01.05.1992
Association for Research in Vision and Ophtalmology |
Subjects | |
Online Access | Get full text |
ISSN | 0146-0404 1552-5783 |
Cover
Loading…
Abstract | The authors previously found that measurements of precorneal tear film thickness in animals, using laser interferometry and confocal microscopy, were larger than earlier estimates. They proposed that this occurred because optical methods did not disturb film structure and measured full thickness, including mucus. In the present study, tear film thickness was measured in humans. Coherent light was reflected from eyes and formed interference patterns. Thickness was determined from spacing of fringes. Mean thickness in six subjects was 34-45 microns, more than four times larger than earlier values. Validity and accuracy of measurements by interferometry were examined in our earlier study using confocal microscopy. Here it provided supportive evidence. Tear film thickness was estimated from optical sections through the corneas of three subjects to be 41-46 microns. Mucus content of the film also was examined. Interferometry was used to measure thinning after application of a mucolytic agent. There was no change in thickness after 5 min exposure to 0.1% (weight/volume) acetylcysteine. Solutions of 20% caused thinning to 11 microns, and thickness slowly increased to reach its original value over 40 min. Thus, the film seemed to be composed substantially of mucus, not aqueous fluid. The results also provided evidence that measurements by interferometry did not include underlying epithelium. Earlier nonoptical methods probably did not include the portion of the film that contained mucus. They seem to have greatly underestimated human tear film thickness. |
---|---|
AbstractList | The authors previously found that measurements of precorneal tear film thickness in animals, using laser interferometry and confocal microscopy, were larger than earlier estimates. They proposed that this occurred because optical methods did not disturb film structure and measured full thickness, including mucus. In the present study, tear film thickness was measured in humans. Coherent light was reflected from eyes and formed interference patterns. Thickness was determined from spacing of fringes. Mean thickness in six subjects was 34-45 microns, more than four times larger than earlier values. Validity and accuracy of measurements by interferometry were examined in our earlier study using confocal microscopy. Here it provided supportive evidence. Tear film thickness was estimated from optical sections through the corneas of three subjects to be 41-46 microns. Mucus content of the film also was examined. Interferometry was used to measure thinning after application of a mucolytic agent. There was no change in thickness after 5 min exposure to 0.1% (weight/volume) acetylcysteine. Solutions of 20% caused thinning to 11 microns, and thickness slowly increased to reach its original value over 40 min. Thus, the film seemed to be composed substantially of mucus, not aqueous fluid. The results also provided evidence that measurements by interferometry did not include underlying epithelium. Earlier nonoptical methods probably did not include the portion of the film that contained mucus. They seem to have greatly underestimated human tear film thickness.The authors previously found that measurements of precorneal tear film thickness in animals, using laser interferometry and confocal microscopy, were larger than earlier estimates. They proposed that this occurred because optical methods did not disturb film structure and measured full thickness, including mucus. In the present study, tear film thickness was measured in humans. Coherent light was reflected from eyes and formed interference patterns. Thickness was determined from spacing of fringes. Mean thickness in six subjects was 34-45 microns, more than four times larger than earlier values. Validity and accuracy of measurements by interferometry were examined in our earlier study using confocal microscopy. Here it provided supportive evidence. Tear film thickness was estimated from optical sections through the corneas of three subjects to be 41-46 microns. Mucus content of the film also was examined. Interferometry was used to measure thinning after application of a mucolytic agent. There was no change in thickness after 5 min exposure to 0.1% (weight/volume) acetylcysteine. Solutions of 20% caused thinning to 11 microns, and thickness slowly increased to reach its original value over 40 min. Thus, the film seemed to be composed substantially of mucus, not aqueous fluid. The results also provided evidence that measurements by interferometry did not include underlying epithelium. Earlier nonoptical methods probably did not include the portion of the film that contained mucus. They seem to have greatly underestimated human tear film thickness. The authors previously found that measurements of precorneal tear film thickness in animals, using laser interferometry and confocal microscopy, were larger than earlier estimates. They proposed that this occurred because optical methods did not disturb film structure and measured full thickness, including mucus. In the present study, tear film thickness was measured in humans. Coherent light was reflected from eyes and formed interference patterns. Thickness was determined from spacing of fringes. Mean thickness in six subjects was 34-45 microns, more than four times larger than earlier values. Validity and accuracy of measurements by interferometry were examined in our earlier study using confocal microscopy. Here it provided supportive evidence. Tear film thickness was estimated from optical sections through the corneas of three subjects to be 41-46 microns. Mucus content of the film also was examined. Interferometry was used to measure thinning after application of a mucolytic agent. There was no change in thickness after 5 min exposure to 0.1% (weight/volume) acetylcysteine. Solutions of 20% caused thinning to 11 microns, and thickness slowly increased to reach its original value over 40 min. Thus, the film seemed to be composed substantially of mucus, not aqueous fluid. The results also provided evidence that measurements by interferometry did not include underlying epithelium. Earlier nonoptical methods probably did not include the portion of the film that contained mucus. They seem to have greatly underestimated human tear film thickness. |
Author | Artal, P Woon, H Prydal, JI Campbell, FW |
Author_xml | – sequence: 1 fullname: Prydal, JI – sequence: 2 fullname: Artal, P – sequence: 3 fullname: Woon, H – sequence: 4 fullname: Campbell, FW |
BackLink | http://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=5351416$$DView record in Pascal Francis https://www.ncbi.nlm.nih.gov/pubmed/1582805$$D View this record in MEDLINE/PubMed |
BookMark | eNpFkEtLxDAYRYOMjDOjP0HIQtwV8miSdimDLxBcOLgtMfk6jabpmKQM8-8tWHR1F-dwL9w1WoQhwBlaUSFYIVTFF2hFaCkLUpLyAq1T-iSEUcrIEi2pqFhFxAq9v-XRnvDQ4m7sdcCHCGaIAbTHGXTErfM9zp0zXwFSwjpYnHIcTR4j4DG5sMdeJ4jYhQyxhTj0kOPpEp232ie4mnODdg_3u-1T8fL6-Ly9eyk6JmUuWGkp1FwKTo3USlSS1pYoxRlIK6gUgvOW14QqqFll2xaImUIKWys7sQ26_a09xOF7hJSb3iUD3usAw5gaxWquGGeTeD2L40cPtjlE1-t4auYfJn4zc52M9m3Uwbj0pwkuaEnl_17n9t3RRWhSr72fSmlzPB45b2TDCJH8B8BIdiY |
CODEN | IOVSDA |
ContentType | Journal Article |
Copyright | 1992 INIST-CNRS |
Copyright_xml | – notice: 1992 INIST-CNRS |
DBID | IQODW CGR CUY CVF ECM EIF NPM 7X8 |
DatabaseName | Pascal-Francis Medline MEDLINE MEDLINE (Ovid) MEDLINE MEDLINE PubMed MEDLINE - Academic |
DatabaseTitle | MEDLINE Medline Complete MEDLINE with Full Text PubMed MEDLINE (Ovid) MEDLINE - Academic |
DatabaseTitleList | MEDLINE - Academic MEDLINE |
Database_xml | – sequence: 1 dbid: NPM name: PubMed url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed sourceTypes: Index Database – sequence: 2 dbid: EIF name: MEDLINE url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search sourceTypes: Index Database |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Medicine |
EISSN | 1552-5783 |
EndPage | 2011 |
ExternalDocumentID | 1582805 5351416 www33_6_2006 |
Genre | Research Support, Non-U.S. Gov't Journal Article |
GrantInformation_xml | – fundername: Wellcome Trust |
GroupedDBID | - 08R 2WC 34G 39C 53G 55 5GY 5RE ABFLS ACNCT ADACO ADBBV AENEX AFFNX AJYGW ALMA_UNASSIGNED_HOLDINGS BAWUL CS3 DIK DU5 E3Z EBS EJD F5P GJ GROUPED_DOAJ GX1 N9A OK1 P2P RHF SJN TRV VH1 WH7 WOQ WOW X7M ZA5 ZGI ZXP --- .55 .GJ 18M ACGFO AFOSN AI. IQODW RPM TR2 W8F CGR CUY CVF ECM EIF NPM 7X8 |
ID | FETCH-LOGICAL-h266t-24d1e936531c6a758619d07732e6d5165533f39017e928dffe0c8df65d97d533 |
ISSN | 0146-0404 |
IngestDate | Fri Jul 11 02:15:07 EDT 2025 Sat Sep 28 07:26:28 EDT 2024 Wed Apr 02 07:27:28 EDT 2025 Tue Nov 10 19:48:56 EST 2020 |
IsPeerReviewed | true |
IsScholarly | true |
Issue | 6 |
Keywords | Thickness Tear film Human Eye Laser interferometer Confocal system Microscopy Exploration |
Language | English |
License | CC BY 4.0 |
LinkModel | OpenURL |
MergedId | FETCHMERGED-LOGICAL-h266t-24d1e936531c6a758619d07732e6d5165533f39017e928dffe0c8df65d97d533 |
Notes | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
PMID | 1582805 |
PQID | 72937232 |
PQPubID | 23479 |
PageCount | 6 |
ParticipantIDs | proquest_miscellaneous_72937232 pubmed_primary_1582805 pascalfrancis_primary_5351416 highwire_smallpub1_www33_6_2006 |
ProviderPackageCode | RHF |
PublicationCentury | 1900 |
PublicationDate | 1992-05-01 |
PublicationDateYYYYMMDD | 1992-05-01 |
PublicationDate_xml | – month: 05 year: 1992 text: 1992-05-01 day: 01 |
PublicationDecade | 1990 |
PublicationPlace | Rockville, MD |
PublicationPlace_xml | – name: Rockville, MD – name: United States |
PublicationTitle | Investigative ophthalmology & visual science |
PublicationTitleAlternate | Invest Ophthalmol Vis Sci |
PublicationYear | 1992 |
Publisher | ARVO Association for Research in Vision and Ophtalmology |
Publisher_xml | – name: ARVO – name: Association for Research in Vision and Ophtalmology |
SSID | ssj0021120 |
Score | 1.8136894 |
Snippet | The authors previously found that measurements of precorneal tear film thickness in animals, using laser interferometry and confocal microscopy, were larger... |
SourceID | proquest pubmed pascalfrancis highwire |
SourceType | Aggregation Database Index Database Publisher |
StartPage | 2006 |
SubjectTerms | Adult Biological and medical sciences Cornea - physiology Eye and associated structures. Visual pathways and centers. Vision Female Fundamental and applied biological sciences. Psychology Humans Interferometry Lasers Light Male Microscopy Mucus - physiology Tears - chemistry Tears - physiology Vertebrates: nervous system and sense organs |
Title | Study of human precorneal tear film thickness and structure using laser interferometry |
URI | http://www.iovs.org/cgi/content/abstract/33/6/2006 https://www.ncbi.nlm.nih.gov/pubmed/1582805 https://www.proquest.com/docview/72937232 |
Volume | 33 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1Lb9NAEF7RHhAXxKsiQOkeuCEjr71eJ8cKGhVoCxIu5LZae3eVitSOEqcR_Hpmdv2IpSIeF8eyZUeabzya5zeEvCoirlKlVJCHJg24mahgnFseRIwrgf6sZjgofH4hTi_5h1ky67fwuemSOn9T_Lx1ruR_UIVrgCtOyf4Dst1L4QKcA75wBITh-FcYf2kZof2mvaXLuJRIFYxdusi5hKMjV8V3Z89citzRxWLRYOOSBOA7m5XjjFhZg8wF9XBEeoeG48a8rpbzeq4W1563CZXm5mq9accqex35vPqhlc8t91nZY_TzBxNl3ypf8u-qVbuFkKlv_fMZCd-92vb_dUlKEYBx4LtW1tNdNNo0MJlheAsX9sUnOb08O5PZySzbI3sxw70I795_7IJp1lButv-1Q_CM_a1qDSpu_W6S3wcPzonIHpD7jfdPjz2UD8kdUz4id8-b_obH5KtDlFaWOkRpjyhFRCkiSjtEKSBKO0SpQ5Q6ROkQ0Sckm55kb0-DZvNFMAeHqQ4iDp_IJBZgIAuhIKSDMFeHaRpHRuiEiQScdIvZqtRMorG21oQF_IhET1IN9w7IflmV5imh4djaMddawGfIGctVAQGqtUkUWpGqgo_IUSs2ub5WiwWIh8ntdhvHUuCOUjEihwNpyqWnQZEJDoEwuH_USleCacJ6kypNtVlLiNviFDz2ETnwQu8eZVisDZNnf3z0ObnXa9gLsg8iNYfgBdb5S6cOvwBgu2cC |
linkProvider | Flying Publisher |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Study+of+human+precorneal+tear+film+thickness+and+structure+using+laser+interferometry&rft.jtitle=Investigative+ophthalmology+%26+visual+science&rft.au=Prydal%2C+J+I&rft.au=Artal%2C+P&rft.au=Woon%2C+H&rft.au=Campbell%2C+F+W&rft.date=1992-05-01&rft.issn=0146-0404&rft.volume=33&rft.issue=6&rft.spage=2006&rft.externalDBID=NO_FULL_TEXT |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0146-0404&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0146-0404&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0146-0404&client=summon |