Regional Reproducibility of BOLD Calibration Parameter M, OEF and Resting-State CMRO.sub.2 Measurements with QUO2 MRI

The current generation of calibrated MRI methods goes beyond simple localization of task-related responses to allow the mapping of resting-state cerebral metabolic rate of oxygen (CMRO.sub.2) in micromolar units and estimation of oxygen extraction fraction (OEF). Prior to the adoption of such techni...

Full description

Saved in:
Bibliographic Details
Published inPloS one Vol. 11; no. 9; p. e0163071
Main Authors Lajoie, Isabelle, Tancredi, Felipe B, Hoge, Richard D
Format Journal Article
LanguageEnglish
Published Public Library of Science 20.09.2016
Subjects
Online AccessGet full text
ISSN1932-6203
1932-6203
DOI10.1371/journal.pone.0163071

Cover

Abstract The current generation of calibrated MRI methods goes beyond simple localization of task-related responses to allow the mapping of resting-state cerebral metabolic rate of oxygen (CMRO.sub.2) in micromolar units and estimation of oxygen extraction fraction (OEF). Prior to the adoption of such techniques in neuroscience research applications, knowledge about the precision and accuracy of absolute estimates of CMRO.sub.2 and OEF is crucial and remains unexplored to this day. In this study, we addressed the question of methodological precision by assessing the regional inter-subject variance and intra-subject reproducibility of the BOLD calibration parameter M, OEF, O.sub.2 delivery and absolute CMRO.sub.2 estimates derived from a state-of-the-art calibrated BOLD technique, the QUantitative O2 (QUO2) approach. We acquired simultaneous measurements of CBF and R2* at rest and during periods of hypercapnia (HC) and hyperoxia (HO) on two separate scan sessions within 24 hours using a clinical 3 T MRI scanner. Maps of M, OEF, oxygen delivery and CMRO.sub.2, were estimated from the measured end-tidal O.sub.2, CBF.sub.0, CBF.sub.HC/HO and R2*.sub.HC/HO . Variability was assessed by computing the between-subject coefficients of variation (bwCV) and within-subject CV (wsCV) in seven ROIs. All tests GM-averaged values of CBF.sub.0, M, OEF, O.sub.2 delivery and CMRO.sub.2 were: 49.5 ± 6.4 mL/100 g/min, 4.69 ± 0.91%, 0.37 ± 0.06, 377 ± 51 [mu]mol/100 g/min and 143 ± 34 [mu]mol/100 g/min respectively. The variability of parameter estimates was found to be the lowest when averaged throughout all GM, with general trends toward higher CVs when averaged over smaller regions. Among the MRI measurements, the most reproducible across scans was R2*.sub.0 (wsCV.sub.GM = 0.33%) along with CBF.sub.0 (wsCV.sub.GM = 3.88%) and R2*.sub.HC (wsCV.sub.GM = 6.7%). CBF.sub.HC and R2*.sub.HO were found to have a higher intra-subject variability (wsCV.sub.GM = 22.4% and wsCV.sub.GM = 16% respectively), which is likely due to propagation of random measurement errors, especially for CBF.sub.HC due to the low contrast-to-noise ratio intrinsic to ASL. Reproducibility of the QUO2 derived estimates were computed, yielding a GM intra-subject reproducibility of 3.87% for O.sub.2 delivery, 16.8% for the M value, 13.6% for OEF and 15.2% for CMRO.sub.2 . Although these results focus on the precision of the QUO2 method, rather than the accuracy, the information will be useful for calculation of statistical power in future validation studies and ultimately for research applications of the method. The higher test-retest variability for the more extensively modeled parameters (M, OEF, and CMRO.sub.2) highlights the need for further improvement of acquisition methods to reduce noise levels.
AbstractList The current generation of calibrated MRI methods goes beyond simple localization of task-related responses to allow the mapping of resting-state cerebral metabolic rate of oxygen (CMRO.sub.2) in micromolar units and estimation of oxygen extraction fraction (OEF). Prior to the adoption of such techniques in neuroscience research applications, knowledge about the precision and accuracy of absolute estimates of CMRO.sub.2 and OEF is crucial and remains unexplored to this day. In this study, we addressed the question of methodological precision by assessing the regional inter-subject variance and intra-subject reproducibility of the BOLD calibration parameter M, OEF, O.sub.2 delivery and absolute CMRO.sub.2 estimates derived from a state-of-the-art calibrated BOLD technique, the QUantitative O2 (QUO2) approach. We acquired simultaneous measurements of CBF and R2* at rest and during periods of hypercapnia (HC) and hyperoxia (HO) on two separate scan sessions within 24 hours using a clinical 3 T MRI scanner. Maps of M, OEF, oxygen delivery and CMRO.sub.2, were estimated from the measured end-tidal O.sub.2, CBF.sub.0, CBF.sub.HC/HO and R2*.sub.HC/HO . Variability was assessed by computing the between-subject coefficients of variation (bwCV) and within-subject CV (wsCV) in seven ROIs. All tests GM-averaged values of CBF.sub.0, M, OEF, O.sub.2 delivery and CMRO.sub.2 were: 49.5 ± 6.4 mL/100 g/min, 4.69 ± 0.91%, 0.37 ± 0.06, 377 ± 51 [mu]mol/100 g/min and 143 ± 34 [mu]mol/100 g/min respectively. The variability of parameter estimates was found to be the lowest when averaged throughout all GM, with general trends toward higher CVs when averaged over smaller regions. Among the MRI measurements, the most reproducible across scans was R2*.sub.0 (wsCV.sub.GM = 0.33%) along with CBF.sub.0 (wsCV.sub.GM = 3.88%) and R2*.sub.HC (wsCV.sub.GM = 6.7%). CBF.sub.HC and R2*.sub.HO were found to have a higher intra-subject variability (wsCV.sub.GM = 22.4% and wsCV.sub.GM = 16% respectively), which is likely due to propagation of random measurement errors, especially for CBF.sub.HC due to the low contrast-to-noise ratio intrinsic to ASL. Reproducibility of the QUO2 derived estimates were computed, yielding a GM intra-subject reproducibility of 3.87% for O.sub.2 delivery, 16.8% for the M value, 13.6% for OEF and 15.2% for CMRO.sub.2 . Although these results focus on the precision of the QUO2 method, rather than the accuracy, the information will be useful for calculation of statistical power in future validation studies and ultimately for research applications of the method. The higher test-retest variability for the more extensively modeled parameters (M, OEF, and CMRO.sub.2) highlights the need for further improvement of acquisition methods to reduce noise levels.
Audience Academic
Author Lajoie, Isabelle
Hoge, Richard D
Tancredi, Felipe B
Author_xml – sequence: 1
  fullname: Lajoie, Isabelle
– sequence: 2
  fullname: Tancredi, Felipe B
– sequence: 3
  fullname: Hoge, Richard D
BookMark eNqNkE1Lw0AQhhdRsH78Aw8LgiCYuLtpN8lR61ehJRqt1zKbnaQraVKyG9R_74oeWvAgc5jh5Xnm8B6Q3aZtkJATzkIexfzyre27Bupw7eOQcRmxmO-QAU8jEUjBot2Ne58cWPvG2ChKpByQPsfKtF6mOa67VveFUaY27pO2Jb3Opjd0DLVRHThP0UfoYIUOOzq7oNntHYVGe9E601TBswOHdDzLs9D2KhR0hmD7DlfYOEvfjVvSp3nm43xyRPZKqC0e_-5DMr-7fRk_BNPsfjK-mgYVl1IEaiRGasi11iwWqIWQkkdJzLkWkdIgmYjTIS-kKksUMBKYpGWqBXClOHLA6JCc_vytoMaFacrWdVCsjC0WV8OYJ-mQJcJT4R-UH40rU_hOS-PzLeF8S_CMww9XQW_tYvKc_5_NXrfZsw12iVC7pW3r_rt7uwl-ARHZmJA
ContentType Journal Article
Copyright COPYRIGHT 2016 Public Library of Science
Copyright_xml – notice: COPYRIGHT 2016 Public Library of Science
DBID IOV
ISR
DOI 10.1371/journal.pone.0163071
DatabaseName Gale In Context: Opposing Viewpoints
Gale In Context: Science
DatabaseTitleList

DeliveryMethod fulltext_linktorsrc
Discipline Sciences (General)
EISSN 1932-6203
ExternalDocumentID A471894082
GroupedDBID ---
123
29O
2WC
53G
5VS
7RV
7X2
7X7
7XC
88E
8AO
8C1
8CJ
8FE
8FG
8FH
8FI
8FJ
A8Z
AAFWJ
AAUCC
AAWOE
ABDBF
ABIVO
ABJCF
ABUWG
ACGFO
ACIHN
ACIWK
ACPRK
ACUHS
ADBBV
ADRAZ
AEAQA
AENEX
AEUYN
AFKRA
AFPKN
AFRAH
AHMBA
ALIPV
ALMA_UNASSIGNED_HOLDINGS
AOIJS
APEBS
ARAPS
ATCPS
BAWUL
BBNVY
BBORY
BCNDV
BENPR
BGLVJ
BHPHI
BKEYQ
BPHCQ
BVXVI
BWKFM
CCPQU
CS3
D1I
D1J
D1K
DIK
DU5
E3Z
EAP
EAS
EBD
EMOBN
ESX
EX3
F5P
FPL
FYUFA
GROUPED_DOAJ
GX1
HCIFZ
HH5
HMCUK
HYE
IAO
IEA
IGS
IHR
IHW
INH
INR
IOV
IPY
ISE
ISR
ITC
K6-
KB.
KQ8
L6V
LK5
LK8
M0K
M1P
M48
M7P
M7R
M7S
M~E
NAPCQ
O5R
O5S
OK1
P2P
P62
PATMY
PDBOC
PHGZM
PHGZT
PIMPY
PQQKQ
PROAC
PSQYO
PTHSS
PV9
PYCSY
RNS
RPM
RZL
SV3
TR2
UKHRP
WOQ
WOW
~02
~KM
OVT
PMFND
ID FETCH-LOGICAL-g1662-b525b41ddd072ed2266138711d23bda6027941c6bffe2a52e89f9d2a1bb1e1ae3
IEDL.DBID M48
ISSN 1932-6203
IngestDate Tue Jun 17 21:12:00 EDT 2025
Tue Jun 10 20:36:14 EDT 2025
Fri Jun 27 04:43:16 EDT 2025
Fri Jun 27 03:43:35 EDT 2025
Thu May 22 21:21:53 EDT 2025
IsPeerReviewed true
IsScholarly true
Issue 9
Language English
LinkModel DirectLink
MergedId FETCHMERGED-LOGICAL-g1662-b525b41ddd072ed2266138711d23bda6027941c6bffe2a52e89f9d2a1bb1e1ae3
PageCount e0163071
ParticipantIDs gale_infotracmisc_A471894082
gale_infotracacademiconefile_A471894082
gale_incontextgauss_ISR_A471894082
gale_incontextgauss_IOV_A471894082
gale_healthsolutions_A471894082
PublicationCentury 2000
PublicationDate 20160920
PublicationDateYYYYMMDD 2016-09-20
PublicationDate_xml – month: 09
  year: 2016
  text: 20160920
  day: 20
PublicationDecade 2010
PublicationTitle PloS one
PublicationYear 2016
Publisher Public Library of Science
Publisher_xml – name: Public Library of Science
SSID ssj0053866
Score 2.193026
Snippet The current generation of calibrated MRI methods goes beyond simple localization of task-related responses to allow the mapping of resting-state cerebral...
SourceID gale
SourceType Aggregation Database
StartPage e0163071
SubjectTerms Magnetic resonance imaging
Measurement
Medical imaging equipment
Title Regional Reproducibility of BOLD Calibration Parameter M, OEF and Resting-State CMRO.sub.2 Measurements with QUO2 MRI
Volume 11
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV1LTxsxELYQvXCpoKXikVKrQqKV2GjtON74UKGUJgLEdtu0Qdwie23ngjZtNpGaS387M46hRCqCyx6845U19ux8M54HIYfKpcL6LE1KUFeJwDgq4y1LdOa9BY3ItMcE5_yrPBuKi-v29Rq569kaGVj_17TDflLD6U3zz-_FCQj8p9C1IWN3k5q_JpVrAoSBYwv20AvQTRLNsVzc3yuAdIfbS0QtieRpKybTPfaV-J9-oHH6m-RlhIq0u9zbLbLmqldkKwpjTT_EitEfX5P5wI2DS48Cng4lXJcxrws68fRzcfmFYgqWWW42_aYxIAv4SfNjWvT6VFcWJtYYAJ0E8ElP80ERumNxmv9zItYUvbb0-7CA4cH5Nhn2ez9Pz5LYTyEZMyl5Ytq8bQSz1qYZd5ajbm6BwcQsbxmrJVioSrBSGu8d123uOsoryzUzhjmmXesNWa-AOzuE8szzMstK4ZUSNlUdmepO6Yw1ihvZEbvkHTJutEzmvJeiURd1ocIm17vkfaDAGhQVBrmM9byuR-fF1TOIfgxWiI4ikZ_MprrUMbEAVoq1rVYoGyuUIEnlg9d7Ty56n2wAYJIYL8LTBlmfTefuLYCSmTkIxvxBOG34_Nu7BQUu4Ss
linkProvider Scholars Portal
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Regional+Reproducibility+of+BOLD+Calibration+Parameter+M%2C+OEF+and+Resting-State+CMRO.sub.2+Measurements+with+QUO2+MRI&rft.jtitle=PloS+one&rft.au=Lajoie%2C+Isabelle&rft.au=Hoge%2C+Richard+D&rft.au=Tancredi%2C+Felipe+B&rft.date=2016-09-20&rft.pub=Public+Library+of+Science&rft.issn=1932-6203&rft.eissn=1932-6203&rft.volume=11&rft.issue=9&rft.spage=e0163071&rft_id=info:doi/10.1371%2Fjournal.pone.0163071&rft.externalDBID=n%2Fa&rft.externalDocID=A471894082
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1932-6203&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1932-6203&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1932-6203&client=summon