Failure of medullary tubes: A materials analysis

The objective of this study is to determine the effects of autoclaving on the stress, strain, ultimate tensile strength (UTS), fracture strain, modulus, and yield stress of nylon medullary tubes. There are three reports describing nylon medullary tube failure in the literature. All cases involved th...

Full description

Saved in:
Bibliographic Details
Published inInjury Vol. 35; no. 9; pp. 878 - 882
Main Authors Taub, Marc, Wera, Glenn, Dauskardt, Reinhold H., Mohler, David G.
Format Journal Article
LanguageEnglish
Published Oxford Elsevier Ltd 01.09.2004
Elsevier
Subjects
Online AccessGet full text

Cover

Loading…
Abstract The objective of this study is to determine the effects of autoclaving on the stress, strain, ultimate tensile strength (UTS), fracture strain, modulus, and yield stress of nylon medullary tubes. There are three reports describing nylon medullary tube failure in the literature. All cases involved the use of nylon medullary tubes during open reduction internal fixation of fractured long bones. We demonstrated increased brittleness and decreased strength with increased exposure of medullary tubes to autoclaving, most dramatically after 100 autoclave cycles. Visual inspection of tubes is a clear indication of material degradation after repeated autoclaving. Furthermore, there is a significant difference in ultimate tensile strength ( P<0.0001) between tubes exposed to less than 100 sterilization cycles compared to tubes exposed to greater than 100 cycles. Likewise, there is a significant decrease in yield stress ( P<0.0004) between the same groups. We recommend disposal and replacement of nylon medullary tubes before they are exposed to 100 autoclaving cycles in order to avoid failure of the device.
AbstractList The objective of this study is to determine the effects of autoclaving on the stress, strain, ultimate tensile strength (UTS), fracture strain, modulus, and yield stress of nylon medullary tubes. There are three reports describing nylon medullary tube failure in the literature. All cases involved the use of nylon medullary tubes during open reduction internal fixation of fractured long bones. We demonstrated increased brittleness and decreased strength with increased exposure of medullary tubes to autoclaving, most dramatically after 100 autoclave cycles. Visual inspection of tubes is a clear indication of material degradation after repeated autoclaving. Furthermore, there is a significant difference in ultimate tensile strength (P &lt; 0.0001) between tubes exposed to less than 100 sterilization cycles compared to tubes exposed to greater than 100 cycles. Likewise, there is a significant decrease in yield stress (P &lt; 0.0004) between the same groups. We recommend disposal and replacement of nylon medullary tubes before they are exposed to 100 autoclaving cycles in order to avoid failure of the device.
The objective of this study is to determine the effects of autoclaving on the stress, strain, ultimate tensile strength (UTS), fracture strain, modulus, and yield stress of nylon medullary tubes. There are three reports describing nylon medullary tube failure in the literature. All cases involved the use of nylon medullary tubes during open reduction internal fixation of fractured long bones. We demonstrated increased brittleness and decreased strength with increased exposure of medullary tubes to autoclaving, most dramatically after 100 autoclave cycles. Visual inspection of tubes is a clear indication of material degradation after repeated autoclaving. Furthermore, there is a significant difference in ultimate tensile strength (P < 0.0001) between tubes exposed to less than 100 sterilization cycles compared to tubes exposed to greater than 100 cycles. Likewise, there is a significant decrease in yield stress (P < 0.0004) between the same groups. We recommend disposal and replacement of nylon medullary tubes before they are exposed to 100 autoclaving cycles in order to avoid failure of the device.
The objective of this study is to determine the effects of autoclaving on the stress, strain, ultimate tensile strength (UTS), fracture strain, modulus, and yield stress of nylon medullary tubes. There are three reports describing nylon medullary tube failure in the literature. All cases involved the use of nylon medullary tubes during open reduction internal fixation of fractured long bones. We demonstrated increased brittleness and decreased strength with increased exposure of medullary tubes to autoclaving, most dramatically after 100 autoclave cycles. Visual inspection of tubes is a clear indication of material degradation after repeated autoclaving. Furthermore, there is a significant difference in ultimate tensile strength ( P<0.0001) between tubes exposed to less than 100 sterilization cycles compared to tubes exposed to greater than 100 cycles. Likewise, there is a significant decrease in yield stress ( P<0.0004) between the same groups. We recommend disposal and replacement of nylon medullary tubes before they are exposed to 100 autoclaving cycles in order to avoid failure of the device.
Author Wera, Glenn
Taub, Marc
Mohler, David G.
Dauskardt, Reinhold H.
Author_xml – sequence: 1
  givenname: Marc
  surname: Taub
  fullname: Taub, Marc
  organization: Department of Materials Science and Engineering, Stanford University, 416 Escondido Mall, Building 550, Stanford, CA 94305-2205, USA
– sequence: 2
  givenname: Glenn
  surname: Wera
  fullname: Wera, Glenn
  organization: Department of Orthopaedics, Case Western Reserve University, University Hospitals of Cleveland, 11100 Euclid Avenue Cleveland, OH 44106, USA
– sequence: 3
  givenname: Reinhold H.
  surname: Dauskardt
  fullname: Dauskardt, Reinhold H.
  organization: Department of Materials Science and Engineering, Stanford University, 416 Escondido Mall, Building 550, Stanford, CA 94305-2205, USA
– sequence: 4
  givenname: David G.
  surname: Mohler
  fullname: Mohler, David G.
  email: docmohler@aol.com
  organization: Department of Orthopaedic Surgery and Sports Medicine, Stanford University Medical Center, 454 Forest Ave, Palo Alto, CA 94301, USA
BackLink http://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=16060486$$DView record in Pascal Francis
https://www.ncbi.nlm.nih.gov/pubmed/15302240$$D View this record in MEDLINE/PubMed
BookMark eNpFkMtKAzEUQIMo9qGfoMxG0cXozWOS1I2UYlUouFDXIZO5A5F51MmM0L83tVUhcAkcLvecCTls2gYJOaNwQ4HK21cABinlml8BvwbgoFJ-QMZUq1kKTKpDMv5DRmQSwgcAVcD5MRnRjANjAsYEltZXQ4dJWyY1FkNV2W6T9EOO4S6ZJ7XtsfO2ColtbLUJPpyQozL-8XQ_p-R9-fC2eEpXL4_Pi_kqRTbjfVq4TKi8UCUozmhWUouKORBiVtKMaSeFzKQUCAqpcEJTLrJSCyG15pbllk_J5W7vums_Bwy9qX1wGO9rsB2CkVIpnqlZBM_34JBHA7PufB0dzK9jBC72gA3OVmVnG-fDPydBgtAycvc7DqPWl8fOBOexcVj4Dl1vitYbCmZb3_zUN9u0BuLb1jecfwM9wHQh
CODEN INJUBF
ContentType Journal Article
Copyright 2003 Elsevier Ltd
2004 INIST-CNRS
Copyright_xml – notice: 2003 Elsevier Ltd
– notice: 2004 INIST-CNRS
DBID IQODW
CGR
CUY
CVF
ECM
EIF
NPM
7X8
DOI 10.1016/S0020-1383(03)00307-3
DatabaseName Pascal-Francis
Medline
MEDLINE
MEDLINE (Ovid)
MEDLINE
MEDLINE
PubMed
MEDLINE - Academic
DatabaseTitle MEDLINE
Medline Complete
MEDLINE with Full Text
PubMed
MEDLINE (Ovid)
MEDLINE - Academic
DatabaseTitleList MEDLINE - Academic
MEDLINE

Database_xml – sequence: 1
  dbid: NPM
  name: PubMed
  url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed
  sourceTypes: Index Database
– sequence: 2
  dbid: EIF
  name: MEDLINE
  url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search
  sourceTypes: Index Database
DeliveryMethod fulltext_linktorsrc
EISSN 1879-0267
EndPage 882
ExternalDocumentID 15302240
16060486
S0020138303003073
Genre Journal Article
GroupedDBID ---
--K
--M
.1-
.55
.FO
.GJ
.~1
0R~
1B1
1P~
1RT
1~.
1~5
29I
4.4
457
4G.
53G
5GY
5RE
5VS
7-5
71M
8P~
9JM
AABNK
AACTN
AAEDT
AAEDW
AAIAV
AAIKJ
AAKOC
AALRI
AAOAW
AAQFI
AAQXK
AAWTL
AAXUO
ABBQC
ABFNM
ABJNI
ABLJU
ABLVK
ABMAC
ABMZM
ABXDB
ABYKQ
ACDAQ
ACGFS
ACIUM
ACRLP
ADBBV
ADEZE
ADMUD
AEBSH
AEKER
AEVXI
AFCTW
AFKWA
AFRHN
AFTJW
AFXIZ
AGHFR
AGUBO
AGYEJ
AHHHB
AHPSJ
AIEXJ
AIKHN
AITUG
AJBFU
AJOXV
AJRQY
AJUYK
ALMA_UNASSIGNED_HOLDINGS
AMFUW
AMRAJ
ANZVX
ASPBG
AVWKF
AXJTR
AZFZN
BKOJK
BLXMC
BNPGV
CS3
EBS
EFJIC
EFLBG
EJD
EO8
EO9
EP2
EP3
F5P
FDB
FEDTE
FGOYB
FIRID
FNPLU
FYGXN
G-2
G-Q
GBLVA
HEE
HMK
HMO
HVGLF
HZ~
IHE
J1W
K-O
KOM
KQ8
L7B
LCYCR
M29
M31
M41
MO0
N9A
O-L
O9-
OAUVE
OF~
OR-
OZT
P-8
P-9
PC.
Q38
R2-
RIG
ROL
RPZ
SAE
SCC
SDF
SDG
SDP
SEL
SES
SEW
SPCBC
SSH
SSZ
T5K
UV1
WUQ
X7M
XPP
Z5R
ZGI
ZXP
~02
~G-
08R
AAPBV
AAUGY
ABPIF
ABPTK
IQODW
AAXKI
AFJKZ
CGR
CUY
CVF
ECM
EIF
NPM
7X8
ID FETCH-LOGICAL-e293t-dc547bd7f073215f1ae72c0449f1528c6465664e07e14c481345f8446883a2ba3
IEDL.DBID AIKHN
ISSN 0020-1383
IngestDate Fri Aug 16 13:22:57 EDT 2024
Sat Sep 28 07:41:08 EDT 2024
Sun Oct 22 16:05:36 EDT 2023
Fri Feb 23 02:25:27 EST 2024
IsPeerReviewed true
IsScholarly true
Issue 9
Keywords Biomechanics
Nylon
Material science
Trauma
Medullary tubes
Orthopaedic
Hardware failure
Tube
Analysis
Orthopedics
Materials
Anesthesia
Failure
Resuscitation
Language English
License CC BY 4.0
LinkModel DirectLink
MergedId FETCHMERGED-LOGICAL-e293t-dc547bd7f073215f1ae72c0449f1528c6465664e07e14c481345f8446883a2ba3
Notes ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
PMID 15302240
PQID 66773579
PQPubID 23479
PageCount 5
ParticipantIDs proquest_miscellaneous_66773579
pubmed_primary_15302240
pascalfrancis_primary_16060486
elsevier_sciencedirect_doi_10_1016_S0020_1383_03_00307_3
PublicationCentury 2000
PublicationDate 2004-09-01
PublicationDateYYYYMMDD 2004-09-01
PublicationDate_xml – month: 09
  year: 2004
  text: 2004-09-01
  day: 01
PublicationDecade 2000
PublicationPlace Oxford
PublicationPlace_xml – name: Oxford
– name: Netherlands
PublicationTitle Injury
PublicationTitleAlternate Injury
PublicationYear 2004
Publisher Elsevier Ltd
Elsevier
Publisher_xml – name: Elsevier Ltd
– name: Elsevier
References Vakharia, Lehto, Mohler (BIB3) 2000; 14
Ip D, Wu WC, Wong SH. Rare complication of segmental breakage of plastic medullary tube in crossed intramedullary nailing. Injury 2001;32(9):730–1.
Godsiff, Heywood-Waddington (BIB2) 1993; 24
References_xml – volume: 14
  start-page: 514
  year: 2000
  end-page: 517
  ident: BIB3
  article-title: Multiple fracture of medullary tube during intramedullary nailing of long bone fractures
  publication-title: J. Orthop. Trauma
  contributor:
    fullname: Mohler
– volume: 24
  start-page: 136
  year: 1993
  end-page: 137
  ident: BIB2
  article-title: Closed intramedullary nailing complicated by breakage of plastic medullary tube
  publication-title: Injury
  contributor:
    fullname: Heywood-Waddington
SSID ssj0017033
Score 1.7810675
Snippet The objective of this study is to determine the effects of autoclaving on the stress, strain, ultimate tensile strength (UTS), fracture strain, modulus, and...
SourceID proquest
pubmed
pascalfrancis
elsevier
SourceType Aggregation Database
Index Database
Publisher
StartPage 878
SubjectTerms Anesthesia. Intensive care medicine. Transfusions. Cell therapy and gene therapy
Biological and medical sciences
Biomechanics
Diseases of the osteoarticular system
Equipment Failure
Fracture Fixation - instrumentation
Hardware failure
Humans
Material science
Materials Testing
Medical sciences
Medullary tubes
Nylon
Nylons
Orthopaedic
Orthopedic Equipment
Stress, Mechanical
Trauma
Traumas. Diseases due to physical agents
Title Failure of medullary tubes: A materials analysis
URI https://dx.doi.org/10.1016/S0020-1383(03)00307-3
https://www.ncbi.nlm.nih.gov/pubmed/15302240
https://search.proquest.com/docview/66773579
Volume 35
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV07T8MwED71sSAhBOIVHiUDAwyhTuzEDltVURUQnajUzXISW-qSVm06sPDbOccpVQcWVktnOV9O993pXgD3dmk1zeM4yBlLA8YyEygTYaiSClLwLDQpt_3OH5NkPGVvs3jWguG2F8aWVTa239n02lo3J_0Gzf5yPrc9vpFNs6ENdprahi7SEWMd6A5e38eT32QCKrVLNGOkZAV2jTzukvrwgdDH-p6A7vHS4VKtES3j1lz87YfWfDQ6hqPGkfQH7q0n0NLlKZCRmts6c39hfJTB8FKtvvxqk-n1sz_w0Tt1CuerZhbJGUxHL5_DcdDsRAg0EnMVFHnMeFZwgx-MbG1CpXmUEwTaIBOLPLHzzxKmCdchy5kIKYuNwJhPCKqiTNFz6JSLUl-CL1AwFAVGiChfqFzFKVFckMRYr40JD8QWBrn3SyRaW7mrDkMEpUVQEiprBCX1oLcHm1y60RkyTOywHpF4cLfFUaI-2ySFKvVis5ZJwjmNeerBhYN3J2sXHKEDcvX_d13Dgau8sTViN9CpVht9i05FlfWg_fQd9hrV-QGbO8Pj
link.rule.ids 315,786,790,4521,24144,27955,27956,45618,45712
linkProvider Elsevier
linkToHtml http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV07T8MwED6VMoCEEIhXeLQZGGAITWIndtiqiqpA26mVullOYktd0qpNBxZ-O-c4perAwmrlLOfz6R7yd3cAj2ZoNcmiyMsoTTxKU-1JHWKqknA_Z2mgE2bqnUfjeDClH7No1oDethbG0Cpr229temWt65VOjWZnOZ-bGt_QPLOhDbaaegCHJhowvK6X71-eR4AqbZ-ZMU8yn-_KeOwW1eKTT56rXTyy55VOlnKNWGk75OLvKLTyRv0zOK3DSLdrT3oODVVcgN-Xc8MydxfaRRlMLuXqyy03qVq_ul0XY1Orbq6sO5FcwrT_NukNvHoigqfQLZdenkWUpTnT-Lvoq3UgFQszH2HW6Id5FpvuZzFVPlMBzSgPCI00x4yPcyLDVJIraBaLQt2Ay1Ew4Dnmhyify0xGiS8Z92NtYjbKHeBbGMTehQi0tWLHDUMEhUFQ-ERUCAriQGsPNrG0jTNEEJtWPTx2oL3FUaA2mycKWajFZi3imDESscSBawvvTtaMN8Lw4_b_52rD0WAyGorh-_jzDo4tB8ewxe6hWa426gHDizJtVerzA0dGxLg
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Failure+of+medullary+tubes.+A+materials+analysis&rft.jtitle=Injury&rft.au=Taub%2C+Marc&rft.au=Wera%2C+Glenn&rft.au=Dauskardt%2C+Reinhold+H&rft.au=Mohler%2C+David+G&rft.date=2004-09-01&rft.issn=0020-1383&rft.volume=35&rft.issue=9&rft.spage=878&rft_id=info:doi/10.1016%2FS0020-1383%2803%2900307-3&rft_id=info%3Apmid%2F15302240&rft.externalDocID=15302240
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0020-1383&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0020-1383&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0020-1383&client=summon