Quantification of glutathione transverse relaxation time T2 using echo time extension with variable refocusing selectivity and symmetry in the human brain at 7 Tesla

[Display omitted] •Glutathione (GSH) T2 was measured in the human occipital cortex at 7 Tesla.•Variable TE extension pulse selectivity and symmetry maximized GSH quantifiability.•Signals were quantified by linear combination model fits of simulated basis sets.•T2 of GSH was calculated to be 145.0 ± ...

Full description

Saved in:
Bibliographic Details
Published inJournal of magnetic resonance (1997) Vol. 290; pp. 1 - 11
Main Authors Swanberg, Kelley M., Prinsen, Hetty, Coman, Daniel, de Graaf, Robin A., Juchem, Christoph
Format Journal Article
LanguageEnglish
Published Elsevier Inc 01.05.2018
Subjects
Online AccessGet full text

Cover

Loading…
Abstract [Display omitted] •Glutathione (GSH) T2 was measured in the human occipital cortex at 7 Tesla.•Variable TE extension pulse selectivity and symmetry maximized GSH quantifiability.•Signals were quantified by linear combination model fits of simulated basis sets.•T2 of GSH was calculated to be 145.0 ± 20.1 ms in nine healthy adults.•T2 correction stabilized decreases in apparent GSH concentration at high TE. Glutathione (GSH) is an endogenous antioxidant implicated in numerous biological processes, including those associated with multiple sclerosis, aging, and cancer. Spectral editing techniques have greatly facilitated the acquisition of glutathione signal in living humans via proton magnetic resonance spectroscopy, but signal quantification at 7 Tesla is still hampered by uncertainty about the glutathione transverse decay rate T2 relative to those of commonly employed quantitative references like N-acetyl aspartate (NAA), total creatine, or water. While the T2 of uncoupled singlets can be derived in a straightforward manner from exponential signal decay as a function of echo time, similar estimation of signal decay in GSH is complicated by a spin system that involves both weak and strong J-couplings as well as resonances that overlap those of several other metabolites and macromolecules. Here, we extend a previously published method for quantifying the T2 of GABA, a weakly coupled system, to quantify T2 of the strongly coupled spin system glutathione in the human brain at 7 Tesla. Using full density matrix simulation of glutathione signal behavior, we selected an array of eight optimized echo times between 72 and 322 ms for glutathione signal acquisition by J-difference editing (JDE). We varied the selectivity and symmetry parameters of the inversion pulses used for echo time extension to further optimize the intensity, simplicity, and distinctiveness of glutathione signals at chosen echo times. Pairs of selective adiabatic inversion pulses replaced nonselective pulses at three extended echo times, and symmetry of the time intervals between the two extension pulses was adjusted at one extended echo time to compensate for J-modulation, thereby resulting in appreciable signal-to-noise ratio and quantifiable signal shapes at all measured points. Glutathione signal across all echo times fit smooth monoexponential curves over ten scans of occipital cortex voxels in nine subjects. The T2 of glutathione was calculated to be 145.0 ± 20.1 ms (mean ± standard deviation); this result was robust within one standard deviation to changes in metabolite fitting baseline corrections and removal of individual data points on the signal decay curve. The measured T2 of NAA (222.1 ± 24.7 ms) and total creatine (153.0 ± 19.9 ms) were both higher than that calculated for GSH. Apparent glutathione concentration quantified relative to both reference metabolites increased by up to 32% and 6%, respectively, upon correction with calculated T2 values, emphasizing the importance of considering T2 relaxation differences in the spectroscopic measurement of these metabolites, especially at longer echo times.
AbstractList [Display omitted] •Glutathione (GSH) T2 was measured in the human occipital cortex at 7 Tesla.•Variable TE extension pulse selectivity and symmetry maximized GSH quantifiability.•Signals were quantified by linear combination model fits of simulated basis sets.•T2 of GSH was calculated to be 145.0 ± 20.1 ms in nine healthy adults.•T2 correction stabilized decreases in apparent GSH concentration at high TE. Glutathione (GSH) is an endogenous antioxidant implicated in numerous biological processes, including those associated with multiple sclerosis, aging, and cancer. Spectral editing techniques have greatly facilitated the acquisition of glutathione signal in living humans via proton magnetic resonance spectroscopy, but signal quantification at 7 Tesla is still hampered by uncertainty about the glutathione transverse decay rate T2 relative to those of commonly employed quantitative references like N-acetyl aspartate (NAA), total creatine, or water. While the T2 of uncoupled singlets can be derived in a straightforward manner from exponential signal decay as a function of echo time, similar estimation of signal decay in GSH is complicated by a spin system that involves both weak and strong J-couplings as well as resonances that overlap those of several other metabolites and macromolecules. Here, we extend a previously published method for quantifying the T2 of GABA, a weakly coupled system, to quantify T2 of the strongly coupled spin system glutathione in the human brain at 7 Tesla. Using full density matrix simulation of glutathione signal behavior, we selected an array of eight optimized echo times between 72 and 322 ms for glutathione signal acquisition by J-difference editing (JDE). We varied the selectivity and symmetry parameters of the inversion pulses used for echo time extension to further optimize the intensity, simplicity, and distinctiveness of glutathione signals at chosen echo times. Pairs of selective adiabatic inversion pulses replaced nonselective pulses at three extended echo times, and symmetry of the time intervals between the two extension pulses was adjusted at one extended echo time to compensate for J-modulation, thereby resulting in appreciable signal-to-noise ratio and quantifiable signal shapes at all measured points. Glutathione signal across all echo times fit smooth monoexponential curves over ten scans of occipital cortex voxels in nine subjects. The T2 of glutathione was calculated to be 145.0 ± 20.1 ms (mean ± standard deviation); this result was robust within one standard deviation to changes in metabolite fitting baseline corrections and removal of individual data points on the signal decay curve. The measured T2 of NAA (222.1 ± 24.7 ms) and total creatine (153.0 ± 19.9 ms) were both higher than that calculated for GSH. Apparent glutathione concentration quantified relative to both reference metabolites increased by up to 32% and 6%, respectively, upon correction with calculated T2 values, emphasizing the importance of considering T2 relaxation differences in the spectroscopic measurement of these metabolites, especially at longer echo times.
Glutathione (GSH) is an endogenous antioxidant implicated in numerous biological processes, including those associated with multiple sclerosis, aging, and cancer. Spectral editing techniques have greatly facilitated the acquisition of glutathione signal in living humans via proton magnetic resonance spectroscopy, but signal quantification at 7 Tesla is still hampered by uncertainty about the glutathione transverse decay rate T2 relative to those of commonly employed quantitative references like N-acetyl aspartate (NAA), total creatine, or water. While the T2 of uncoupled singlets can be derived in a straightforward manner from exponential signal decay as a function of echo time, similar estimation of signal decay in GSH is complicated by a spin system that involves both weak and strong J-couplings as well as resonances that overlap those of several other metabolites and macromolecules. Here, we extend a previously published method for quantifying the T2 of GABA, a weakly coupled system, to quantify T2 of the strongly coupled spin system glutathione in the human brain at 7 Tesla. Using full density matrix simulation of glutathione signal behavior, we selected an array of eight optimized echo times between 72 and 322 ms for glutathione signal acquisition by J-difference editing (JDE). We varied the selectivity and symmetry parameters of the inversion pulses used for echo time extension to further optimize the intensity, simplicity, and distinctiveness of glutathione signals at chosen echo times. Pairs of selective adiabatic inversion pulses replaced nonselective pulses at three extended echo times, and symmetry of the time intervals between the two extension pulses was adjusted at one extended echo time to compensate for J-modulation, thereby resulting in appreciable signal-to-noise ratio and quantifiable signal shapes at all measured points. Glutathione signal across all echo times fit smooth monoexponential curves over ten scans of occipital cortex voxels in nine subjects. The T2 of glutathione was calculated to be 145.0 ± 20.1 ms (mean ± standard deviation); this result was robust within one standard deviation to changes in metabolite fitting baseline corrections and removal of individual data points on the signal decay curve. The measured T2 of NAA (222.1 ± 24.7 ms) and total creatine (153.0 ± 19.9 ms) were both higher than that calculated for GSH. Apparent glutathione concentration quantified relative to both reference metabolites increased by up to 32% and 6%, respectively, upon correction with calculated T2 values, emphasizing the importance of considering T2 relaxation differences in the spectroscopic measurement of these metabolites, especially at longer echo times.Glutathione (GSH) is an endogenous antioxidant implicated in numerous biological processes, including those associated with multiple sclerosis, aging, and cancer. Spectral editing techniques have greatly facilitated the acquisition of glutathione signal in living humans via proton magnetic resonance spectroscopy, but signal quantification at 7 Tesla is still hampered by uncertainty about the glutathione transverse decay rate T2 relative to those of commonly employed quantitative references like N-acetyl aspartate (NAA), total creatine, or water. While the T2 of uncoupled singlets can be derived in a straightforward manner from exponential signal decay as a function of echo time, similar estimation of signal decay in GSH is complicated by a spin system that involves both weak and strong J-couplings as well as resonances that overlap those of several other metabolites and macromolecules. Here, we extend a previously published method for quantifying the T2 of GABA, a weakly coupled system, to quantify T2 of the strongly coupled spin system glutathione in the human brain at 7 Tesla. Using full density matrix simulation of glutathione signal behavior, we selected an array of eight optimized echo times between 72 and 322 ms for glutathione signal acquisition by J-difference editing (JDE). We varied the selectivity and symmetry parameters of the inversion pulses used for echo time extension to further optimize the intensity, simplicity, and distinctiveness of glutathione signals at chosen echo times. Pairs of selective adiabatic inversion pulses replaced nonselective pulses at three extended echo times, and symmetry of the time intervals between the two extension pulses was adjusted at one extended echo time to compensate for J-modulation, thereby resulting in appreciable signal-to-noise ratio and quantifiable signal shapes at all measured points. Glutathione signal across all echo times fit smooth monoexponential curves over ten scans of occipital cortex voxels in nine subjects. The T2 of glutathione was calculated to be 145.0 ± 20.1 ms (mean ± standard deviation); this result was robust within one standard deviation to changes in metabolite fitting baseline corrections and removal of individual data points on the signal decay curve. The measured T2 of NAA (222.1 ± 24.7 ms) and total creatine (153.0 ± 19.9 ms) were both higher than that calculated for GSH. Apparent glutathione concentration quantified relative to both reference metabolites increased by up to 32% and 6%, respectively, upon correction with calculated T2 values, emphasizing the importance of considering T2 relaxation differences in the spectroscopic measurement of these metabolites, especially at longer echo times.
Author Prinsen, Hetty
Swanberg, Kelley M.
Juchem, Christoph
Coman, Daniel
de Graaf, Robin A.
Author_xml – sequence: 1
  givenname: Kelley M.
  orcidid: 0000-0002-1254-190X
  surname: Swanberg
  fullname: Swanberg, Kelley M.
  email: k.swanberg@columbia.edu
  organization: Department of Biomedical Engineering, Columbia University Fu Foundation School of Engineering and Applied Science, 1210 Amsterdam Ave., New York, NY 10027, United States
– sequence: 2
  givenname: Hetty
  surname: Prinsen
  fullname: Prinsen, Hetty
  organization: Department of Radiology and Biomedical Imaging, Yale University School of Medicine, 330 Cedar Street, New Haven, CT 06520, United States
– sequence: 3
  givenname: Daniel
  surname: Coman
  fullname: Coman, Daniel
  organization: Department of Radiology and Biomedical Imaging, Yale University School of Medicine, 330 Cedar Street, New Haven, CT 06520, United States
– sequence: 4
  givenname: Robin A.
  surname: de Graaf
  fullname: de Graaf, Robin A.
  organization: Department of Radiology and Biomedical Imaging, Yale University School of Medicine, 330 Cedar Street, New Haven, CT 06520, United States
– sequence: 5
  givenname: Christoph
  surname: Juchem
  fullname: Juchem, Christoph
  organization: Department of Biomedical Engineering, Columbia University Fu Foundation School of Engineering and Applied Science, 1210 Amsterdam Ave., New York, NY 10027, United States
BookMark eNotkclOxDAMhiMEEusDcMuRS0ucki7ihBCbhISQhnOUpg7NqE0hSQfmgXhPMpSTt8-W7f-Y7LvJISHnwHJgUF6u8_Xoc86gzhnPGVR75AhYU2asFuX-n8-yqmbVITkOYc0YgKjYEfl5nZWL1litop0cnQx9H-aoYp8ipNErFzboA1KPg_peoGhHpCtO52DdO0XdT0sKvyO6sCO-bOzpRnmr2mHXaia9wAEH1NFubNxS5ToatuOI0W-pTWN7pP08Kkdbr1KsIq3oCsOgTsmBUUPAs397Qt7u71a3j9nzy8PT7c1zhiBEzATDQkOpr7r2qmmBYdmazmArBKARBstU1bpJbykNLzhyEI1usYPWNB1gXZyQi2Xuh58-ZwxRjjZoHAblcJqDTP_lDed1AQm9XlBM-2wsehm0Raexsz5dKLvJSmByJ45cyyTOrrmWjMskTvELXVKLNg
ContentType Journal Article
Copyright 2018 Elsevier Inc.
Copyright © 2018 Elsevier Inc. All rights reserved.
Copyright_xml – notice: 2018 Elsevier Inc.
– notice: Copyright © 2018 Elsevier Inc. All rights reserved.
DBID 7X8
DOI 10.1016/j.jmr.2018.02.017
DatabaseName MEDLINE - Academic
DatabaseTitle MEDLINE - Academic
DatabaseTitleList
MEDLINE - Academic
DeliveryMethod fulltext_linktorsrc
Discipline Chemistry
Physics
EISSN 1096-0856
EndPage 11
ExternalDocumentID S1090780718300715
GroupedDBID ---
--K
--M
-~X
.GJ
.~1
0R~
1B1
1RT
1~.
1~5
29K
4.4
457
4G.
53G
5GY
5RE
5VS
7-5
71M
8P~
AACTN
AAEDT
AAEDW
AAIAV
AAIKJ
AAKOC
AALRI
AAOAW
AAQFI
AAQXK
AARLI
AAXUO
ABBQC
ABFNM
ABGSF
ABJNI
ABLJU
ABLVK
ABMAC
ABMZM
ABNEU
ABUDA
ABXDB
ABYKQ
ACDAQ
ACFVG
ACGFS
ACNCT
ACNNM
ACRLP
ADBBV
ADECG
ADEZE
ADFGL
ADMUD
ADUVX
AEBSH
AEHWI
AEKER
AENEX
AFFNX
AFKWA
AFTJW
AFXIZ
AFZHZ
AGHFR
AGRDE
AGUBO
AGYEJ
AIEXJ
AIKHN
AITUG
AIVDX
AJBFU
AJOXV
AJRQY
AJSZI
ALMA_UNASSIGNED_HOLDINGS
AMFUW
AMRAJ
ANZVX
ASPBG
AVWKF
AXJTR
AZFZN
BKOJK
BLXMC
BNPGV
CAG
COF
CS3
D-I
DM4
DOVZS
DU5
EBS
EFBJH
EFLBG
EJD
EO8
EO9
EP2
EP3
F5P
FA8
FDB
FEDTE
FGOYB
FIRID
FLBIZ
FNPLU
FYGXN
G-Q
G8K
GBLVA
HVGLF
HZ~
IHE
J1W
KOM
LCYCR
LG5
M41
MO0
N9A
O-L
O9-
OAUVE
OGIMB
OZT
P-8
P-9
P2P
PC.
Q38
R2-
RIG
RNS
ROL
RPZ
SCB
SDF
SDG
SDP
SES
SEW
SPC
SPCBC
SSH
SSK
SSQ
SSU
SSZ
T5K
UPT
UQL
XPP
YQT
ZA5
ZCG
ZGI
ZXP
~02
~G-
7X8
AATTM
AAXKI
AAYWO
ACIEU
ACVFH
ADCNI
ADVLN
AEIPS
AEUPX
AFPUW
AGCQF
AGRNS
AIIUN
AKBMS
AKRWK
AKYEP
ANKPU
APXCP
ID FETCH-LOGICAL-e155t-50e3c16c4db49b10e6bfdfeb551ef5fe63c1cc90966f232e2159cbed1bf9d1e83
IEDL.DBID .~1
ISSN 1090-7807
1096-0856
IngestDate Thu Jul 10 23:12:43 EDT 2025
Fri Feb 23 02:24:16 EST 2024
IsPeerReviewed true
IsScholarly true
Keywords Echo time extension
MEGA-sLASER
GSH
T2
Metabolite quantification
J-difference editing
Glutathione
7 Tesla
Language English
LinkModel DirectLink
MergedId FETCHMERGED-LOGICAL-e155t-50e3c16c4db49b10e6bfdfeb551ef5fe63c1cc90966f232e2159cbed1bf9d1e83
Notes ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ORCID 0000-0002-1254-190X
PQID 2012922831
PQPubID 23479
PageCount 11
ParticipantIDs proquest_miscellaneous_2012922831
elsevier_sciencedirect_doi_10_1016_j_jmr_2018_02_017
PublicationCentury 2000
PublicationDate May 2018
20180501
PublicationDateYYYYMMDD 2018-05-01
PublicationDate_xml – month: 05
  year: 2018
  text: May 2018
PublicationDecade 2010
PublicationTitle Journal of magnetic resonance (1997)
PublicationYear 2018
Publisher Elsevier Inc
Publisher_xml – name: Elsevier Inc
References Choi, Zhao, Dimitrov, Douglas, Coupland, Kalra, Hawesa, Davis (b0075) 2009; 198
Provencher (b0175) 1993; 30
Cudalbu, Mlynarik, Gruetter (b0065) 2012; 31
Lally, An, Banerjee, Niciu, Luckenbaugh, Richards, Roiser, Shen, Zarate, Nugent (b0045) 2016; 43
Klomp, Bitz, Heerschap, Scheenen (b0100) 2009; 22
Emir, Deelchand, Henry, Terpstra (b0115) 2011; 24
K.M. Swanberg, H. Prinsen, D. Coman, R.A. de Graaf, C. Juchem, In vivo quantification of glutathione T2 in the human brain at 7 Tesla using echo time extension with variable refocusing selectivity and symmetry, in: Proceedings of 25th International Society for Magnetic Resonance in Medicine, Honolulu, Hawaii, 2017.
Klose (b0160) 1990; 14
Emir, Larkin, de Pennington, Voets, Plaha, Stacey, Al-Qahtani, Mccullagh, Schofield, Clare, Jezzard, Cadoux-Hudson, Ansorge (b0050) 2016; 76
de Graaf, Chowdhury, Behar (b0140) 2011; 83
Govindaraju, Young, Maudsley (b0150) 2000; 13
Choi, Coupland, Bhardwaj, Kalra, Casault, Reid, Allen (b0080) 2006; 56
Rae, Williams (b0030) 2017; 529
Koga, Serritella, Sawa, Sedlak (b0025) 2016; 176
de Graaf, Rothman (b0090) 2001; 152
Michaeli, Garwood, Zhu, DelaBarre, Andersen, Adriany, Merkle, Ugurbil, Chen (b0195) 2002; 47
Slomp (b0095) 1969; 2
Andreychenko, Boer, Arteaga de Castro, Luijten, Klomp (b0125) 2012; 68
Posse, Cuenod, Risinger, Le Bihan, Balaban (b0200) 1995; 33
Juchem, Nixon, McIntyre, Boer, Rothman, de Graaf (b0155) 2011; 212
de Graaf, Nicolay (b0105) 1997; 9
Marjanska, Auerbach, Valabregue, Van de Moortele, Adriany, Garwood (b0060) 2012; 25
Andreychenko, Klomp, de Graaf, Luijten, Boer (b0085) 2013; 26
Dias, Junn, Mouradian (b0015) 2013; 3
J.J. Moré, The Levenberg-Marquardt algorithm: Implementation and theory, in: Numerical Analysis, Springer, 2006, pp. 105–116.
Prinsen, de Graaf, Mason, Pelletier, Juchem (b0130) 2016
Nocedal, Wright (b0190) 1999
Smith, Levante, Meier, Ernst (b0145) 1994; 106
Ganji, Banerjee, Patel, Zhao, Dimitrov, Browning, Brown, Maher, Choi (b0220) 2012; 25
Mann, Davies, Boggild, Alldersea, Fryer, Jones, Ko Ko, Young, Strange, Hawkins (b0010) 2000; 54
Carvalho, Lim, Nijland, Witte, Van Horssen (b0035) 2014; 20
Garwood, DelaBarre (b0205) 2001; 153
Carr, Purcell (b0210) 1954; 94
Kumar, Delshad, Woo, Macey, Harper (b0230) 2012; 35
Saharan, Mandal (b0020) 2014; 40
An, Li, Murdoch, Araneta, Johnson, Shen (b0055) 2015; 73
Jiru, Skoch, Wagnerova, Dezortova, Viskova, Profant, Syka, Hajek (b0225) 2016; 29
O'Leary, Rust (b0185) 2013; 54
Allerhand (b0215) 1966; 44
Cavassila, Deval, Huegen, van Ormondt, Graveron-Demilly (b0180) 2001; 14
Bluestein, Pitt, Knopp, Schmalbrock (b0235) 2012; 30
Trabesinger, Weber, Duc, Boesiger (b0040) 1999; 42
Terpstra, Henry, Gruetter (b0070) 2003; 50
Tkac, Starcuk, Choi, Gruetter (b0135) 1999; 41
de Graaf (b0005) 2007
Kaiser, Young, Matson (b0110) 2008; 195
Wright, Wald (b0165) 1997; 10
References_xml – volume: 10
  start-page: 394
  year: 1997
  end-page: 410
  ident: b0165
  article-title: Theory and application of array coils in MR spectroscopy
  publication-title: NMR Biomed.
– volume: 83
  start-page: 216
  year: 2011
  end-page: 224
  ident: b0140
  article-title: Quantification of high-resolution H-1 NMR spectra from rat brain extracts
  publication-title: Anal. Chem.
– volume: 2
  start-page: 263
  year: 1969
  ident: b0095
  article-title: Analysis of ABX spectra in NMR spectroscopy
  publication-title: Appl. Spectrosc. Rev.
– volume: 24
  start-page: 263
  year: 2011
  end-page: 269
  ident: b0115
  article-title: Noninvasive quantification of
  publication-title: NMR Biomed.
– volume: 529
  start-page: 127
  year: 2017
  end-page: 143
  ident: b0030
  article-title: Glutathione in in the human brain: review of its roles and measurement by magnetic resonance spectroscopy
  publication-title: Anal. Biochem.
– volume: 106
  start-page: 75
  year: 1994
  end-page: 105
  ident: b0145
  article-title: Computer-simulations in magnetic-resonance – an object-oriented programming approach
  publication-title: J. Magn. Reson. Ser. A
– volume: 153
  start-page: 155
  year: 2001
  end-page: 177
  ident: b0205
  article-title: The return of the frequency sweep: designing adiabatic pulses for contemporary NMR
  publication-title: J. Magn. Reson.
– volume: 94
  start-page: 630
  year: 1954
  end-page: 638
  ident: b0210
  article-title: Effects of diffusion on free precession in nuclear magnetic resonance experiments
  publication-title: Phys. Rev.
– volume: 40
  start-page: 519
  year: 2014
  end-page: 529
  ident: b0020
  article-title: The emerging role of glutathione in Alzheimer's disease
  publication-title: J. Alzheimer's Dis.
– volume: 76
  start-page: 43
  year: 2016
  end-page: 49
  ident: b0050
  article-title: Noninvasive quantification of 2-hydroxyglutarate in human gliomas with IDH1 and IDH2 mutations
  publication-title: Cancer Res.
– volume: 13
  start-page: 129
  year: 2000
  end-page: 153
  ident: b0150
  article-title: Proton NMR chemical shifts and coupling constants for brain metabolites
  publication-title: NMR Biomed.
– volume: 26
  start-page: 1596
  year: 2013
  end-page: 1601
  ident: b0085
  article-title: In vivo GABA T-2 determination with J-refocused echo time extension at 7 T
  publication-title: NMR Biomed.
– volume: 47
  start-page: 629
  year: 2002
  end-page: 633
  ident: b0195
  article-title: Proton T2 relaxation study of water, N-acetylaspartate, and creatine in human brain using Hahn and Carr-Purcell spin echoes at 4 T and 7 T
  publication-title: Magn. Reson. Med.
– volume: 152
  start-page: 124
  year: 2001
  end-page: 131
  ident: b0090
  article-title: Detection of gamma-aminobutyric acid (GABA) by longitudinal scalar order difference editing
  publication-title: J. Magn. Reson.
– volume: 54
  start-page: 552
  year: 2000
  end-page: 557
  ident: b0010
  article-title: Glutathione S-transferase polymorphisms in MS: their relationship to disability
  publication-title: Neurology
– reference: J.J. Moré, The Levenberg-Marquardt algorithm: Implementation and theory, in: Numerical Analysis, Springer, 2006, pp. 105–116.
– volume: 73
  start-page: 451
  year: 2015
  end-page: 458
  ident: b0055
  article-title: Detection of glutamate, glutamine, and glutathione by radiofrequency suppression and echo time optimization at 7 Tesla
  publication-title: Magn. Reson. Med.
– volume: 25
  start-page: 332
  year: 2012
  end-page: 339
  ident: b0060
  article-title: Localized
  publication-title: NMR Biomed.
– volume: 56
  start-page: 971
  year: 2006
  end-page: 977
  ident: b0080
  article-title: measurement and quantification of glutamate in human brain in vivo
  publication-title: Magn. Reson. Med.
– volume: 14
  start-page: 278
  year: 2001
  end-page: 283
  ident: b0180
  article-title: Cramer-Rao bounds: an evaluation tool for quantitation
  publication-title: NMR Biomed.
– volume: 44
  year: 1966
  ident: b0215
  article-title: Analysis of Carr-Purcell spin-echo NMR experiments on multiple-spin systems. I. The effect of homonuclear coupling
  publication-title: J. Chem. Phys.
– volume: 3
  start-page: 461
  year: 2013
  end-page: 491
  ident: b0015
  article-title: The role of oxidative stress in Parkinson's disease
  publication-title: J. Parkinson's Dis.
– volume: 22
  start-page: 495
  year: 2009
  end-page: 501
  ident: b0100
  article-title: Proton spectroscopic imaging of the human prostate at 7 T
  publication-title: NMR Biomed.
– volume: 14
  start-page: 26
  year: 1990
  end-page: 30
  ident: b0160
  article-title: In vivo proton spectroscopy in presence of eddy currents
  publication-title: Magn. Reson. Med.
– volume: 198
  start-page: 160
  year: 2009
  end-page: 166
  ident: b0075
  article-title: Measurement of glutathione in human brain at 3 T using an improved double quantum filter in vivo
  publication-title: J. Magn. Reson.
– volume: 176
  start-page: 52
  year: 2016
  end-page: 71
  ident: b0025
  article-title: Implications for reactive oxygen species in schizophrenia pathogenesis
  publication-title: Schizophr. Res.
– year: 1999
  ident: b0190
  article-title: Numerical Optimization
– volume: 35
  start-page: 300
  year: 2012
  end-page: 308
  ident: b0230
  article-title: Age-related regional brain
  publication-title: J. Magn. Reson. Imaging
– volume: 42
  start-page: 283
  year: 1999
  end-page: 289
  ident: b0040
  article-title: Detection of glutathione in the human brain in vivo by means of double quantum coherence filtering
  publication-title: Magn. Reson. Med.
– volume: 30
  start-page: 19
  year: 2012
  end-page: 25
  ident: b0235
  article-title: and proton density at 7 T in patients with multiple sclerosis: an initial study
  publication-title: Magn. Reson. Imaging
– year: 2007
  ident: b0005
  article-title: In Vivo NMR Spectroscopy: Principles and Techniques
– volume: 195
  start-page: 67
  year: 2008
  end-page: 75
  ident: b0110
  article-title: Numerical simulations of localized high field
  publication-title: J. Magn. Reson.
– volume: 33
  start-page: 246
  year: 1995
  end-page: 252
  ident: b0200
  article-title: Anomalous transverse relaxation in 1H spectroscopy in human brain at 4 Tesla
  publication-title: Magn. Reson. Med.
– volume: 29
  start-page: 284
  year: 2016
  end-page: 292
  ident: b0225
  article-title: The age dependence of
  publication-title: NMR Biomed.
– volume: 54
  start-page: 579
  year: 2013
  end-page: 593
  ident: b0185
  article-title: Variable projection for nonlinear least squares problems
  publication-title: Comput. Optim. Appl.
– year: 2016
  ident: b0130
  article-title: Reproducibility measurement of glutathione, GABA, and glutamate: towards in vivo neurochemical profiling of multiple sclerosis with MR spectroscopy at 7 T
  publication-title: J. Magn. Reson. Imaging
– volume: 25
  start-page: 523
  year: 2012
  end-page: 529
  ident: b0220
  article-title: measurement of
  publication-title: NMR Biomed.
– volume: 30
  start-page: 672
  year: 1993
  end-page: 679
  ident: b0175
  article-title: Estimation of metabolite concentrations from localized in vivo proton NMR spectra
  publication-title: Magn. Reson. Med.
– volume: 20
  start-page: 1425
  year: 2014
  end-page: 1431
  ident: b0035
  article-title: Glutathione in multiple sclerosis: more than just an antioxidant?
  publication-title: Multiple Sclerosis
– volume: 43
  start-page: 88
  year: 2016
  end-page: 98
  ident: b0045
  article-title: Reliability of 7 T H-1-MRS measured human prefrontal cortex glutamate, glutamine, and glutathione signals using an adapted echo time optimized PRESS sequence: a between- and within-sessions investigation
  publication-title: J. Magn. Reson. Imaging
– volume: 31
  start-page: S101
  year: 2012
  end-page: 115
  ident: b0065
  article-title: Handling macromolecule signals in the quantification of the neurochemical profile
  publication-title: J. Alzheimers Dis.
– volume: 41
  start-page: 649
  year: 1999
  end-page: 656
  ident: b0135
  article-title: In vivo
  publication-title: Magn. Reson. Med.
– volume: 68
  start-page: 1018
  year: 2012
  end-page: 1025
  ident: b0125
  article-title: Efficient spectral editing at 7 T: GABA detection with MEGA-sLASER
  publication-title: Magn. Reson. Med.
– volume: 50
  start-page: 19
  year: 2003
  end-page: 23
  ident: b0070
  article-title: Measurement of reduced glutathione (GSH) in human brain using LCmodel analysis of difference-edited spectra
  publication-title: Magn. Reson. Med.
– volume: 9
  start-page: 247
  year: 1997
  end-page: 268
  ident: b0105
  article-title: Adiabatic RF pulses: applications to in vivo NMR
  publication-title: Concept Magn. Res.
– reference: K.M. Swanberg, H. Prinsen, D. Coman, R.A. de Graaf, C. Juchem, In vivo quantification of glutathione T2 in the human brain at 7 Tesla using echo time extension with variable refocusing selectivity and symmetry, in: Proceedings of 25th International Society for Magnetic Resonance in Medicine, Honolulu, Hawaii, 2017.
– volume: 212
  start-page: 280
  year: 2011
  end-page: 288
  ident: b0155
  article-title: Dynamic multi-coil shimming of the human brain at 7 T
  publication-title: J. Magn. Reson.
SSID ssj0011570
Score 2.2953825
Snippet [Display omitted] •Glutathione (GSH) T2 was measured in the human occipital cortex at 7 Tesla.•Variable TE extension pulse selectivity and symmetry maximized...
Glutathione (GSH) is an endogenous antioxidant implicated in numerous biological processes, including those associated with multiple sclerosis, aging, and...
SourceID proquest
elsevier
SourceType Aggregation Database
Publisher
StartPage 1
SubjectTerms 7 Tesla
Echo time extension
Glutathione
GSH
J-difference editing
MEGA-sLASER
Metabolite quantification
Title Quantification of glutathione transverse relaxation time T2 using echo time extension with variable refocusing selectivity and symmetry in the human brain at 7 Tesla
URI https://dx.doi.org/10.1016/j.jmr.2018.02.017
https://www.proquest.com/docview/2012922831
Volume 290
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1NT9wwELUQVVUuiEIR21I0lbiGjTfOh49oVbQUgVR1kbhFdjyGRdos6mYRXPpv-J_MOAkVHDnGcSzHM5oZ22_mCXEonRohKUtkisREXEMqss7ZCFMKl7205BM5Ofn8Iptcql9X6dWaGPe5MAyr7Gx_a9ODte5aht1qDu9ms-EfhhTmBbnIImFHyYnmSuWs5Uf_XmAeXEumrUigGTkX5_3NZsB43c65JKgsQtnOwFn23yG9Mc3B35xsic0uUITjdi6fxRrW2-LTuOdn2xYfA3izWu6Ip98r02J-wjLDwsM1KRTjChc1QsPuiNEXCJy58tB2YlJ5mI6Age_XgGQF26ZwKs5HaMBHtHBPe2nOrqJP_aJqOy8Dd05gnQBTO1g-zudIc4IZDXuDEHj_wDL5BJgGcpgiKd4XcXnyczqeRB39QoQUZDRRGmNSyaxSziptZYyZ9c6jpRgLfeoxo7dVpWkPlHmKy5CCB11ZdNJ67SQWya5Yr-k39wQYr6VxhU2UsipPTZHGSepibZTTylXZQKh-4ctX0i_JsJc9EO22JHmVLK8yHpUkr4H40QuppMXnqw5T42K15E4jzZV95Nf3Df1NbPBTC23cF-vN3xV-p_CjsQdBvw7Eh-PTs8nFM7sq3yY
linkProvider Elsevier
linkToHtml http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV3fb9MwELZGJzReEAzQNn4dEq9R48ZO48epYurYVgnRSXuz7Pg8OqkpoikafxD_J3dOAoJHXm3Hcu5Od2f7831CvJdBTZCMJXNV4TKuIZX5EHyGmtLlKD3FRH6cfLUo59fq442-2ROz4S0Mwyp739_59OSt-5ZxL83x19Vq_JkhhdOKQmRVcKDUD8Q-V6fSI7F_en4xX_y-TJB62hUlMAyey6fD5WaCed2tuSqorFLlzkRb9icm_eOdU8g5eyIe97kinHbLeSr2sDkUB7OBou1QPEz4zXr7TPz8tHMd7CdJGjYRbsmmGFq4aRBajkgMwEDgxyv33SDmlYflBBj7fgtIjrBrSgfjfIoGfEoL32k7zQ-s6NO4qbvB20Sfk4gnwDUBtj_Wa6Q1wYqm_YKQqP_AM_8EuBamsESyvefi-uzDcjbPegaGDCnPaDOdY1HLslbBK-NljqWPIaKnNAujjlhSb10b2gaVkVIzpPzB1B6D9NEEiVXxQowa-s0jAS4a6ULlC6U8KclVOi90yI1TwahQl8dCDYK3fxmAJd9uByzanSV9WdaXzSeW9HUs3g1KsiR8vu1wDW52Wx40MVzcR57839RvxcF8eXVpL88XFy_FI-7pkI6vxKj9tsPXlI20_k1vbb8AXj3h1w
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Quantification+of+glutathione+transverse+relaxation+time+T2+using+echo+time+extension+with+variable+refocusing+selectivity+and+symmetry+in+the+human+brain+at+7+Tesla&rft.jtitle=Journal+of+magnetic+resonance+%281997%29&rft.au=Swanberg%2C+Kelley+M.&rft.au=Prinsen%2C+Hetty&rft.au=Coman%2C+Daniel&rft.au=de+Graaf%2C+Robin+A.&rft.date=2018-05-01&rft.pub=Elsevier+Inc&rft.issn=1090-7807&rft.eissn=1096-0856&rft.volume=290&rft.spage=1&rft.epage=11&rft_id=info:doi/10.1016%2Fj.jmr.2018.02.017&rft.externalDocID=S1090780718300715
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1090-7807&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1090-7807&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1090-7807&client=summon