ELISA Cut-off Point for the Diagnosis of Human Brucellosis; a Comparison with Serum Agglutination Test
Brucellosis is a world-wide disease, which has a diverse clinical manifestation, and its diagnosis has to be proven by laboratory data. Serum agglutination test (SAT) is the most-widely used test for diagnosing brucellosis. The enzyme linked immunosorbent assay (ELISA) can also determine specific an...
Saved in:
Published in | Iranian journal of medical sciences Vol. 37; no. 1; pp. 9 - 14 |
---|---|
Main Authors | , , , , , , , |
Format | Journal Article |
Language | English |
Published |
Iran
Shiraz University of Medical Sciences
01.03.2012
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Abstract | Brucellosis is a world-wide disease, which has a diverse clinical manifestation, and its diagnosis has to be proven by laboratory data. Serum agglutination test (SAT) is the most-widely used test for diagnosing brucellosis. The enzyme linked immunosorbent assay (ELISA) can also determine specific antibody classes against brucella. It is a sensitive, simple and rapid test, which could be an acceptable alternative to SAT with fewer limitations, however, like any other new test it should be further evaluated and standardized for various populations. This study was planned to determine an optimal cut-off point, for ELISA which would offer maximum sensitivity and specificity for the test when compared to SAT.
Four hundred and seven patients with fever and other compatible symptoms of brucellosis were enrolled in the study. Serum agglutination test, 2-Mercaptoethanol test, and ELISA were performed on their sera.
The cut-off point of 53 IU/ml of ELISA-IgG yielded the maximal sensitivity and specificity comparing to the other levels of ELISA-IgG, and was considered the best cut off-point of ELISA-IgG to diagnose acute brucellosis. At this cut-off, the sensitivity, specificity, positive predictive value, negative predictive value, positive likelihood ratio, and negative likelihood ratio were 84.09%, 85.38%, 62.20, 94.90, 5.75, 0.18, respectively.
The best cut-off point of ELISA-IgG is 53 IU/ml, which yields the maximal sensitivity and specificity to diagnose acute brucellosis. |
---|---|
AbstractList | BACKGROUNDBrucellosis is a world-wide disease, which has a diverse clinical manifestation, and its diagnosis has to be proven by laboratory data. Serum agglutination test (SAT) is the most-widely used test for diagnosing brucellosis. The enzyme linked immunosorbent assay (ELISA) can also determine specific antibody classes against brucella. It is a sensitive, simple and rapid test, which could be an acceptable alternative to SAT with fewer limitations, however, like any other new test it should be further evaluated and standardized for various populations. This study was planned to determine an optimal cut-off point, for ELISA which would offer maximum sensitivity and specificity for the test when compared to SAT. METHODSFour hundred and seven patients with fever and other compatible symptoms of brucellosis were enrolled in the study. Serum agglutination test, 2-Mercaptoethanol test, and ELISA were performed on their sera. RESULTSThe cut-off point of 53 IU/ml of ELISA-IgG yielded the maximal sensitivity and specificity comparing to the other levels of ELISA-IgG, and was considered the best cut off-point of ELISA-IgG to diagnose acute brucellosis. At this cut-off, the sensitivity, specificity, positive predictive value, negative predictive value, positive likelihood ratio, and negative likelihood ratio were 84.09%, 85.38%, 62.20, 94.90, 5.75, 0.18, respectively. CONCLUSIONThe best cut-off point of ELISA-IgG is 53 IU/ml, which yields the maximal sensitivity and specificity to diagnose acute brucellosis. Background: Brucellosis is a world-wide disease, which has a diverse clinical manifestation, and its diagnosis has to be proven by laboratory data. Serum agglutination test (SAT) is the most-widely used test for diagnosing brucellosis. The enzyme linked immunosorbent assay (ELISA) can also determine specific antibody classes against brucella. It is a sensitive, simple and rapid test, which could be an acceptable alternative to SAT with fewer limitations, however, like any other new test it should be further evaluated and standardized for various populations. This study was planned to determine an optimal cut-off point, for ELISA which would offer maximum sensitivity and specificity for the test when compared to SAT. Methods: Four hundred and seven patients with fever and other compatible symptoms of brucellosis were enrolled in the study. Serum agglutination test, 2-Mercaptoethanol test, and ELISA were performed on their sera. Results: The cut-off point of 53 IU/ml of ELISA-IgG yielded the maximal sensitivity and specificity comparing to the other levels of ELISA-IgG, and was considered the best cut off-point of ELISA-IgG to diagnose acute brucellosis. At this cut-off, the sensitivity, specificity, positive predictive value, negative predictive value, positive likelihood ratio, and negative likelihood ratio were 84.09%, 85.38%, 62.20, 94.90, 5.75, 0.18, respectively. Conclusion: The best cut-off point of ELISA-IgG is 53 IU/ml, which yields the maximal sensitivity and specificity to diagnose acute brucellosis. Background: Brucellosis is a world-wide disease, which has a diverse clinical manifestation, and its diagnosis has to be proven by laboratory data. Serum agglutination test (SAT) is the most-widely used test for diagnosing brucellosis. The enzyme linked immunosorbent assay (ELISA) can also determine specific antibody classes against brucella. It is a sensitive, simple and rapid test, which could be an acceptable alternative to SAT with fewer limitations, however, like any other new test it should be further evaluated and standardized for various populations. This study was planned to determine an optimal cut-off point, for ELISA which would offer maximum sensitivity and specificity for the test when compared to SAT.Methods: Four hundred and seven patients with fever and other compatible symptoms of brucellosis were enrolled in the study. Serum agglutination test, 2-Mercaptoethanol test, and ELISA were performed on their sera. Results: The cut-off point of 53 IU/ml of ELISA-IgG yielded the maximal sensitivity and specificity comparing to the other levels of ELISA-IgG, and was considered the best cut off-point of ELISA-IgG to diagnose acute brucellosis. At this cut-off, the sensitivity, specificity, positive predictive value, negative predictive value, positive likelihood ratio, and negative likelihood ratio were 84.09%, 85.38%, 62.20, 94.90, 5.75, 0.18, respectively.Conclusion: The best cut-off point of ELISA-IgG is 53 IU/ml, which yields the maximal sensitivity and specificity to diagnose acute brucellosis. Brucellosis is a world-wide disease, which has a diverse clinical manifestation, and its diagnosis has to be proven by laboratory data. Serum agglutination test (SAT) is the most-widely used test for diagnosing brucellosis. The enzyme linked immunosorbent assay (ELISA) can also determine specific antibody classes against brucella. It is a sensitive, simple and rapid test, which could be an acceptable alternative to SAT with fewer limitations, however, like any other new test it should be further evaluated and standardized for various populations. This study was planned to determine an optimal cut-off point, for ELISA which would offer maximum sensitivity and specificity for the test when compared to SAT. Four hundred and seven patients with fever and other compatible symptoms of brucellosis were enrolled in the study. Serum agglutination test, 2-Mercaptoethanol test, and ELISA were performed on their sera. The cut-off point of 53 IU/ml of ELISA-IgG yielded the maximal sensitivity and specificity comparing to the other levels of ELISA-IgG, and was considered the best cut off-point of ELISA-IgG to diagnose acute brucellosis. At this cut-off, the sensitivity, specificity, positive predictive value, negative predictive value, positive likelihood ratio, and negative likelihood ratio were 84.09%, 85.38%, 62.20, 94.90, 5.75, 0.18, respectively. The best cut-off point of ELISA-IgG is 53 IU/ml, which yields the maximal sensitivity and specificity to diagnose acute brucellosis. |
Author | Karimi, Abdollah Javad, Vadood Shiva, Farideh Angoti, Goli Pournasiri, Zahra Fallah, Fatemeh Sanaei Dashti, Anahita Alaei, Mohammad Reza |
AuthorAffiliation | Pediatric Infections Research Center, Mofid Children’s Hospital, Shahid Beheshti University of Medical Sciences, Tehran, Iran |
AuthorAffiliation_xml | – name: Pediatric Infections Research Center, Mofid Children’s Hospital, Shahid Beheshti University of Medical Sciences, Tehran, Iran |
Author_xml | – sequence: 1 givenname: Anahita surname: Sanaei Dashti fullname: Sanaei Dashti, Anahita organization: Pediatric Infections Research Center, Mofid Children's Hospital, Shahid Beheshti University of Medical Sciences, Tehran, Iran – sequence: 2 givenname: Abdollah surname: Karimi fullname: Karimi, Abdollah – sequence: 3 givenname: Vadood surname: Javad fullname: Javad, Vadood – sequence: 4 givenname: Farideh surname: Shiva fullname: Shiva, Farideh – sequence: 5 givenname: Fatemeh surname: Fallah fullname: Fallah, Fatemeh – sequence: 6 givenname: Mohammad Reza surname: Alaei fullname: Alaei, Mohammad Reza – sequence: 7 givenname: Goli surname: Angoti fullname: Angoti, Goli – sequence: 8 givenname: Zahra surname: Pournasiri fullname: Pournasiri, Zahra |
BackLink | https://www.ncbi.nlm.nih.gov/pubmed/23115425$$D View this record in MEDLINE/PubMed |
BookMark | eNpdkd1rFDEUxYNU7Lb1X5CAL74MJJPPQRDWtdqFhQptn0NmJpnNMpOs-aj435vaKrZPF849_Dj33DNw4oM3r8AKC8IawqU8ASvUMtIggfkpOEvpgBBhWMg34LQlGDPashWwl7vtzRpuSm6CtfB7cD5DGyLMewO_OD35kFyCwcKrsmgPP8cymHl-ED9CDTdhOeroUvDwp8t7eGNiWeB6muaSndfZ1cWtSfkCvLZ6Tubt0zwHd18vbzdXze7623az3jUj4Sg3Vpiu11ZiygfU6a4biTXE9pRx1nNUw4-DpNL0jA31xo5ZpPEg5UiY6W1vyDnYPnLHoA_qGN2i4y8VtFN_hBAnpWN2w2wUsgRhq3vLWkPHgUqMqeSCE6TZ0FNRWZ8eWcfSL2YcjM9Rz8-gzzfe7dUU7hWhArVdWwEfngAx_Ci1BbW49NCe9iaUpDBuOROi62i1vn9hPYQSfa1KYYRaLkgNW13v_k_0L8rfd5Lf1XeebA |
ContentType | Journal Article |
Copyright | Copyright Shiraz University of Medical Sciences Mar 2012 2012: Iranian Journal of Medical Sciences |
Copyright_xml | – notice: Copyright Shiraz University of Medical Sciences Mar 2012 – notice: 2012: Iranian Journal of Medical Sciences |
DBID | NPM 3V. 7X7 7XB 8FI 8FJ 8FK ABUWG AFKRA AZQEC BENPR CCPQU CWDGH DWQXO FYUFA GHDGH K9. M0S PIMPY PQEST PQQKQ PQUKI PRINS 7X8 5PM DOA |
DatabaseName | PubMed ProQuest Central (Corporate) Health & Medical Collection ProQuest Central (purchase pre-March 2016) Hospital Premium Collection Hospital Premium Collection (Alumni Edition) ProQuest Central (Alumni) (purchase pre-March 2016) ProQuest Central (Alumni) ProQuest Central ProQuest Central Essentials ProQuest Central ProQuest One Community College Middle East & Africa Database ProQuest Central Korea Health Research Premium Collection Health Research Premium Collection (Alumni) ProQuest Health & Medical Complete (Alumni) Health & Medical Collection (Alumni Edition) Publicly Available Content Database ProQuest One Academic Eastern Edition (DO NOT USE) ProQuest One Academic ProQuest One Academic UKI Edition ProQuest Central China MEDLINE - Academic PubMed Central (Full Participant titles) DOAJ Directory of Open Access Journals |
DatabaseTitle | PubMed Publicly Available Content Database ProQuest Central Essentials ProQuest One Academic Eastern Edition ProQuest Health & Medical Complete (Alumni) ProQuest Central (Alumni Edition) ProQuest One Community College ProQuest Hospital Collection Health Research Premium Collection (Alumni) ProQuest Central China ProQuest Hospital Collection (Alumni) ProQuest Central ProQuest Health & Medical Complete Health Research Premium Collection Middle East & Africa Database ProQuest One Academic UKI Edition Health and Medicine Complete (Alumni Edition) ProQuest Central Korea ProQuest One Academic ProQuest Central (Alumni) MEDLINE - Academic |
DatabaseTitleList | MEDLINE - Academic PubMed |
Database_xml | – sequence: 1 dbid: DOA name: DOAJ Directory of Open Access Journals url: https://www.doaj.org/ sourceTypes: Open Website – sequence: 2 dbid: NPM name: PubMed url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed sourceTypes: Index Database – sequence: 3 dbid: 7X7 name: Health & Medical Collection url: https://search.proquest.com/healthcomplete sourceTypes: Aggregation Database |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Medicine |
EISSN | 1735-3688 |
EndPage | 14 |
ExternalDocumentID | oai_doaj_org_article_0f301fabf52e4dc48114867630a5cb47 2637890641 23115425 |
Genre | Journal Article General Information |
GroupedDBID | --- 2WC 3V. 53G 5VS 7X7 8FI 8FJ 8R4 8R5 AAKDD AAWTL ABDBF ABUWG ACGFO ACIHN ADBBV ADRAZ AEAQA AFKRA AHMBA ALIPV ALMA_UNASSIGNED_HOLDINGS AOIJS BAWUL BCNDV BENPR BPHCQ BVXVI CCPQU CWDGH DIK E3Z EBD EOJEC ESX FYUFA GROUPED_DOAJ GX1 HMCUK HYE IAO IHR IPNFZ ITC KQ8 L7B M48 MK0 M~E NPM OBODZ OK1 P2P PGMZT PIMPY PQQKQ PROAC PV9 Q2X RIG RNS RPM RZL TR2 TUS UKHRP W2D 7XB 8FK AZQEC DWQXO K9. PQEST PQUKI PRINS 7X8 5PM |
ID | FETCH-LOGICAL-d360t-f7e9baf8146c09a99d3fe3fb4565b60178dc848eb55c36895f0a1c88d35ebfbe3 |
IEDL.DBID | RPM |
ISSN | 0253-0716 |
IngestDate | Tue Oct 22 14:57:45 EDT 2024 Tue Sep 17 21:25:33 EDT 2024 Fri Aug 16 04:15:19 EDT 2024 Thu Oct 10 22:22:09 EDT 2024 Sat Sep 28 07:56:59 EDT 2024 |
IsOpenAccess | true |
IsPeerReviewed | true |
IsScholarly | true |
Issue | 1 |
Keywords | agglutination test brucellosis ELISA |
Language | English |
LinkModel | DirectLink |
MergedId | FETCHMERGED-LOGICAL-d360t-f7e9baf8146c09a99d3fe3fb4565b60178dc848eb55c36895f0a1c88d35ebfbe3 |
Notes | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
OpenAccessLink | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3470292/ |
PMID | 23115425 |
PQID | 1002673301 |
PQPubID | 105767 |
PageCount | 6 |
ParticipantIDs | doaj_primary_oai_doaj_org_article_0f301fabf52e4dc48114867630a5cb47 pubmedcentral_primary_oai_pubmedcentral_nih_gov_3470292 proquest_miscellaneous_1126577994 proquest_journals_1002673301 pubmed_primary_23115425 |
PublicationCentury | 2000 |
PublicationDate | 2012-03-01 |
PublicationDateYYYYMMDD | 2012-03-01 |
PublicationDate_xml | – month: 03 year: 2012 text: 2012-03-01 day: 01 |
PublicationDecade | 2010 |
PublicationPlace | Iran |
PublicationPlace_xml | – name: Iran – name: Shiraz – name: Shiraz, Iran |
PublicationTitle | Iranian journal of medical sciences |
PublicationTitleAlternate | Iran J Med Sci |
PublicationYear | 2012 |
Publisher | Shiraz University of Medical Sciences |
Publisher_xml | – name: Shiraz University of Medical Sciences |
References | 1866536 - Rev Infect Dis. 1991 May-Jun;13(3):359-72 11556041 - East Mediterr Health J. 2000 Mar-May;6(2-3):487-93 9570654 - J Infect. 1998 Mar;36(2):197-201 16358488 - Mikrobiyol Bul. 2005 Jul;39(3):291-9 119612 - Contrib Microbiol Immunol. 1979;5:50-63 11556017 - East Mediterr Health J. 2000 Mar-May;6(2-3):304-12 19754473 - Bosn J Basic Med Sci. 2009 Aug;9(3):198-203 12458117 - Diagn Microbiol Infect Dis. 2002 Oct;44(2):129-32 12797392 - J Chemother. 2003 Apr;15(2):148-51 2768476 - J Clin Microbiol. 1989 Aug;27(8):1909-12 16450537 - East Mediterr Health J. 2003 Sep-Nov;9(5-6):1054-60 12652868 - Mikrobiyol Bul. 2002 Apr;36(2):161-7 16104985 - Clin Microbiol Infect. 2005 Sep;11(9):713-8 10762113 - J Infect. 2000 Jan;40(1):59-63 15562749 - East Mediterr Health J. 2003 Jan-Mar;9(1-2):178-84 17687842 - East Mediterr Health J. 2007 May-Jun;13(3):677-85 8699960 - Medicine (Baltimore). 1996 Jul;75(4):195-211 9407549 - Mol Med. 1997 Nov;3(11):734-9 9204307 - Emerg Infect Dis. 1997 Apr-Jun;3(2):213-21 8705675 - Clin Diagn Lab Immunol. 1996 May;3(3):309-14 |
References_xml | |
SSID | ssj0035178 |
Score | 1.9446671 |
Snippet | Brucellosis is a world-wide disease, which has a diverse clinical manifestation, and its diagnosis has to be proven by laboratory data. Serum agglutination... BACKGROUNDBrucellosis is a world-wide disease, which has a diverse clinical manifestation, and its diagnosis has to be proven by laboratory data. Serum... Background: Brucellosis is a world-wide disease, which has a diverse clinical manifestation, and its diagnosis has to be proven by laboratory data. Serum... Background: Brucellosis is a world-wide disease, which has a diverse clinical manifestation, and its diagnosis has to be proven by laboratory data. Serum... |
SourceID | doaj pubmedcentral proquest pubmed |
SourceType | Open Website Open Access Repository Aggregation Database Index Database |
StartPage | 9 |
SubjectTerms | agglutination test brucellosis ELISA Original |
SummonAdditionalLinks | – databaseName: DOAJ Directory of Open Access Journals dbid: DOA link: http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwrV1NT9wwELUQB9QLaqGUlA8ZiWuE1x-xrZ62CwgQiyoVJG6RnXjoSpBUkP3_HcfZ1S6q1EuvdhJN_MaT58n4mZDTggknYpW4B6VziZwjtwLq3EmljEdGLlXcKDy9K64e5M2jelw56ivWhCV54DRwZwzQBcHho3iQdSVNJPAFzgrmVOVl2kfO7GIxlWKwUKMUg7kScYvOQpH_bzTyfTXkyufl8iPZHnghHSd7PpGN0OyQrenw53uXwMXt9c8xncy7vAWgP9pZ01EknBQJHD1P9XKzN9oC7dPytMfs-Tk2fqOOTpbHDdKYeaUYIuYvdPz0FB0vJQTpPdr7mTxcXtxPrvLhjIS8FgXrctDBegcxkVcx66ytBQQBPhI1j4stberKSBO8UpUojFXA3KgyphYqePBB7JHNpm3CPqG20AGvBWFYkC4o55yCOtTcIccBCRn5Hsew_J1kMMooTN03IFzlAFf5L7gycrhAoBxmy1vUTeaFFnhnRk6W3ejncaBcE9o5XjPihdLaWpmRLwmwpSU8SgZh8MmIXoNyzdT1nmb2q9fSFlIzbvnX__FuB-QD0imeKtQOyWb3Og9HSFk6f9x75x8y9uwv priority: 102 providerName: Directory of Open Access Journals – databaseName: Health & Medical Collection dbid: 7X7 link: http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwfV3daxQxEA9aQXwRv91aJYKvi9l8Bx_kPFuqWBFs4d6WZJOcB3W37e39_87s7p2eiK9JHob8JpPfTCYzhLzRTHiBWeIhK1NK4BylEzmWXiplAzByqfCj8NlXfXohPy_UYgq4rae0yq1NHAx17BqMkb_FUqHagPddvb-6LrFrFL6uTi00bpM7FWcaU7rMYudwCVWNlpgrgR91tnX5_0Um_86J_OOSOXlA7k_skM5GOB-SW6l9RO6eTe_fj0k-_vLp-4zON33Z5Uy_dau2p0A7KdA4-nHMmlutaZfpEJynA3KXlzj4jno63zUdpBh_pWAoNj_pbLlE9RvDgvQc5H1CLk6Oz-en5dQpoYxCs77MJrngM4bzGua8c1HkJHJAuhbA5TI2NlbaFJRqhLZOZearxtooVAo5JPGUHLRdm54T6rRJsDYLy5L0SXnvVY4pcg9MJ8tckA-4h_XVWAyjxvLUw0B3s6wnba9ZBpyyB_x5krGRFr0uDaaMedUEaQpytEWgns7Muv6NcEFe76ZB23GjfJu6DaypuFbGOCcL8mwEbCcJx8JBYIIKYvag3BN1f6Zd_RgqagtpGHf88P9ivSD3gC7xMQPtiBz0N5v0EihJH14NevcL1Arj5Q priority: 102 providerName: ProQuest |
Title | ELISA Cut-off Point for the Diagnosis of Human Brucellosis; a Comparison with Serum Agglutination Test |
URI | https://www.ncbi.nlm.nih.gov/pubmed/23115425 https://www.proquest.com/docview/1002673301 https://search.proquest.com/docview/1126577994 https://pubmed.ncbi.nlm.nih.gov/PMC3470292 https://doaj.org/article/0f301fabf52e4dc48114867630a5cb47 |
Volume | 37 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV3da9swED_aDsZexr7nrQsa7NWNow9LYk9JmtCNpYSthbwZyZbSQGKX1vn_d_JHWMae9mKDJcGhO59_d_7pDuBLmjDDAkvceiFjjpgj1swXseFCKIuInItwUHhxnV7d8u8rsToB0Z-FaUj7ud1clNvdRbm5a7iV97t82PPEhsvFlHGZUE2Hp3CKBtqH6K37ZWLUul8qWDidE3oU0VBShodu2E1d_n-Byb85kX98ZOYv4HmHDsm4leIlnLjyFTxddP-_X4Of_fj2a0ym-zquvCfLalPWBGEnQRhHLlvW3OaRVJ40yXnSaG67DQ-_EkOmh6aDJORfCTqK_Y6M1-tgfm1akNygvG_gdj67mV7FXaeEuGBpUsdeOm2ND-m8PNFG64J5x7wNcM1iyCVVkSuunBUiZ6nSwidmlCtVMOGst469hbOyKt17IDqVDud6phLHjRPGGOELV1CDSMdzH8Ek7GF23xbDyEJ56uZB9bDOOiVliUe_4Q3qnzpe5FyFqCtFV5YYkVsuIzjvNZB178xjqJ5MU8lwZQSfD8No7WGjTOmqPc4Z0VRIqTWP4F2rsIMkvZYjkEeqPBL1eAQNrKmo3RnUh_9e-RGeIZKiLTntHM7qh737hGiltgO00ZUcwJPx5HIyx_tkdr38OWhif7wuuBo09vsb7F3yrw |
link.rule.ids | 230,315,730,783,787,888,2109,2228,12068,21400,31731,31732,33756,33757,43322,43817,53804,53806,74073,74630 |
linkProvider | National Library of Medicine |
linkToHtml | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwfV3fb9MwED7BJgEviN8EBhiJ14g0tmNbPKCudOqgrSbopL1FdmyXSluyren_zzlxC0WIV9sPJ3-Xy-fz-TuAD0VGNQ1V4sZzkTLkHKmi3qaacS4NMnLGw0Ph2byYnLOvF_wiJtzWsaxyGxO7QG2bKuTIPwap0ELg6Xvw-fomDV2jwu1qbKFxFw6DVBUevg6Px_Oz79tYTPmgj8U5p-GpzlaZ_1908u-qyD9-MyeP4GHkh2TYA_oY7rj6CdybxRvwp-DH09MfQzLatGnjPTlrVnVLkHgSJHLkS183t1qTxpMuPU867C4vw-Anoslo13aQhAwswVCxuSLD5TI4YJ8YJAu09xmcn4wXo0kaeyWklhZZm3rhlNE-JPSqTGmlLPWOehMIm8FDl5C2kkw6w3lFC6m4z_SgktJS7ow3jj6Hg7qp3UsgqhAO13oqM8e041pr7q2zuUau45lP4DjsYXndy2GUQaC6G2hul2X09zLziJTX6AG5Y7ZiMpy7CgxmmeaVYSKBoy0CZfxq1uVvjBN4v5tGfw8bpWvXbHDNIC-4EEqxBF70gO0syYN0EAahBMQelHum7s_Uq5-dpjZlIstV_ur_Zr2D-5PFbFpOT-ffXsMDJE95X492BAft7ca9QYLSmrfRC38BkM_oOw |
linkToPdf | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwfV3fb9MwED5BJ028IH6TMcBIvEZLYzuOxQPqulYbbFUFm7S3yE58pdJItjX9_zknbqEI8Wr74eS7fPl8_nwH8DFLuOFeJW5RqlgQ54g1xyo2QsrcEiMX0j8Uvphlp1fiy7W8DvqnVZBVbjCxA-qqKX2O_MiXCs0Unb6HRxhkEfOT6efbu9h3kPI3raGdxkPYUyLjyQD2jiez-bcNLnM57HE5ldw_29lU6f8XtfxbIfnHL2f6BB4HrshGvXOfwgNXP4P9i3Ab_hxwcn72fcTG6zZuENm8WdYtIxLKiNSxk15Dt1yxBlmXqmedH29u_OAnZth424KQ-WwsI9hY_2SjxcIHY58kZJdk7wu4mk4ux6dx6JsQVzxL2hiV09agT-6ViTZaVxwdR-vJm6UDmMqrMhe5s1KWPMu1xMQMyzyvuHQWreMvYVA3tXsNTGfK0VrkeeKEcdIYI7FyVWqI96DACI79Hha3fWmMwher7gaa-0URYr9IkLyGhqIhdaIqRe7PYBkBW2JkaYWK4HDjgSJ8Qavit78j-LCdptj3G2Vq16xpzTDNpFJaiwhe9Q7bWpL6MkIESBGoHVfumLo7Uy9_dPW1uVBJqtOD_5v1HvYpAIvzs9nXN_CIeFTaS9MOYdDer91b4iqtfReC8BcRaexp |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=ELISA+Cut-off+Point+for+the+Diagnosis+of+Human+Brucellosis%3B+a+Comparison+with+Serum+Agglutination+Test&rft.jtitle=Iranian+journal+of+medical+sciences&rft.au=Sanaei+Dashti%2C+Anahita&rft.au=Karimi%2C+Abdollah&rft.au=Javad%2C+Vadood&rft.au=Shiva%2C+Farideh&rft.date=2012-03-01&rft.eissn=1735-3688&rft.volume=37&rft.issue=1&rft.spage=9&rft_id=info%3Apmid%2F23115425&rft.externalDocID=23115425 |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0253-0716&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0253-0716&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0253-0716&client=summon |