Investigation of a non-invasive venous blood flow measurement device

Venous blood circulation can be restricted due to various conditions commonly indicating a related medical condition. However, current non-invasive methods for determining venous blood flow are limited to be either very inaccurate or expensive. Alternatively, a method to measure sap flow non-invasiv...

Full description

Saved in:
Bibliographic Details
Published inCurrent directions in biomedical engineering Vol. 5; no. 1; pp. 179 - 182
Main Authors Stewart, Kent, Dangelmaier, Simon, Pott, Peter, Anders, Jens
Format Journal Article
LanguageEnglish
Published De Gruyter 01.09.2019
Subjects
Online AccessGet full text
ISSN2364-5504
DOI10.1515/cdbme-2019-0045

Cover

Abstract Venous blood circulation can be restricted due to various conditions commonly indicating a related medical condition. However, current non-invasive methods for determining venous blood flow are limited to be either very inaccurate or expensive. Alternatively, a method to measure sap flow non-invasively in trees is through thermal mass measurement principles. This paper investigates applying the thermal mass flow measurement principle to determine venous blood flow. A simplified finite element model (FEM) and simulation are created to determine the operating behavior and expected response of a thermal mass flow meter with venous blood flow under the skin. An initial prototype of a thermal mass venous blood flow meter is designed using a Peltier-element and RTD thermistors. Initial tests were done on N = 8 subjects identifying the presence of blood flow and, testing the devices basic functionality and performance. The simplified FEM model of venous blood flow proved the thermal mass blood flow device is feasible, and determined the initial characteristics of the first prototype. The initial prototype proved to be functional detecting rises in temperature downstream of +1.4 K (0.8 - 1.8 inter- quartile range) when the blood flow was released (t = 90 s after release), compared to when blood was not flowing. The initial prototype proved to be able to detect the presence of blood flow in all subjects. However, further work is required to increase the differences in temperature values or gradient measured for a change in flow rate so the actual flow rate can be determined.
AbstractList Venous blood circulation can be restricted due to various conditions commonly indicating a related medical condition. However, current non-invasive methods for determining venous blood flow are limited to be either very inaccurate or expensive. Alternatively, a method to measure sap flow non-invasively in trees is through thermal mass measurement principles. This paper investigates applying the thermal mass flow measurement principle to determine venous blood flow. A simplified finite element model (FEM) and simulation are created to determine the operating behavior and expected response of a thermal mass flow meter with venous blood flow under the skin. An initial prototype of a thermal mass venous blood flow meter is designed using a Peltier-element and RTD thermistors. Initial tests were done on N = 8 subjects identifying the presence of blood flow and, testing the devices basic functionality and performance. The simplified FEM model of venous blood flow proved the thermal mass blood flow device is feasible, and determined the initial characteristics of the first prototype. The initial prototype proved to be functional detecting rises in temperature downstream of +1.4 K (0.8 - 1.8 inter- quartile range) when the blood flow was released (t = 90 s after release), compared to when blood was not flowing. The initial prototype proved to be able to detect the presence of blood flow in all subjects. However, further work is required to increase the differences in temperature values or gradient measured for a change in flow rate so the actual flow rate can be determined.
Author Stewart, Kent
Anders, Jens
Dangelmaier, Simon
Pott, Peter
Author_xml – sequence: 1
  givenname: Kent
  surname: Stewart
  fullname: Stewart, Kent
  email: kent.stewart@imt.uni-stuttgart.de
  organization: Institut für Medizingerätetechnik, Pfaffenwaldring 9, Stuttgart, Germany
– sequence: 2
  givenname: Simon
  surname: Dangelmaier
  fullname: Dangelmaier, Simon
  organization: Institut für Medizingerätetechnik (IMT), Stuttgart, Germany
– sequence: 3
  givenname: Peter
  surname: Pott
  fullname: Pott, Peter
  organization: Institut für Medizingerätetechnik (IMT), Stuttgart, Germany
– sequence: 4
  givenname: Jens
  surname: Anders
  fullname: Anders, Jens
  organization: Institute of Smart Sensors (ISS), Stuttgart, Germany
BookMark eNotkEtLw0AUhQdRsNau3eYPROedBNxIfRUKbnQ93GTulCnJjEwepf_etHV1DmfxwfnuyHWIAQl5YPSRKaaeGlt3mHPKqpxSqa7Iggstc6WovCWrvt9TSpnmWpdiQV43YcJ-8DsYfAxZdBlkMy_3YYLeT5hNGOLYZ3Ubo81cGw9Zh9CPCTsMQ2Zx8g3ekxsHbY-r_1ySn_e37_Vnvv362KxftrllmlZ5qRVwVggmeaWw4QywVMCwclwr2ZSFdMhpWWtGdaMFcmZlxasCLNbc1lIsyebCtRH25jf5DtLRRPDmPMS0M5AG37RoaqS1oLJx1BWSclVbB06AKAtdaHBqZj1fWAdoB0wWd2k8zsXs45jC_MIwak4-zdmnOfk0J5-KsaISfwhGbqM
ContentType Journal Article
DBID DOA
DOI 10.1515/cdbme-2019-0045
DatabaseName DOAJ Directory of Open Access Journals
DatabaseTitleList

Database_xml – sequence: 1
  dbid: DOA
  name: DOAJ Directory of Open Access Journals
  url: https://www.doaj.org/
  sourceTypes: Open Website
DeliveryMethod fulltext_linktorsrc
Discipline Engineering
EISSN 2364-5504
EndPage 182
ExternalDocumentID oai_doaj_org_article_be0b304cf0f74025bdfaf3a387676af5
10_1515_cdbme_2019_004551179
GroupedDBID 0R~
5VS
AAFWJ
ABFKT
ADBBV
ADMLS
AFPKN
AHGSO
AIKXB
ALMA_UNASSIGNED_HOLDINGS
ARCSS
BCNDV
EBS
EJD
GROUPED_DOAJ
KQ8
M48
M~E
OK1
QD8
SLJYH
ID FETCH-LOGICAL-d1609-865a217314295ec21ae85a1e9f2654c874fe208b6106c63e21d49297adeb2db43
IEDL.DBID M48
IngestDate Wed Aug 27 01:31:46 EDT 2025
Thu Jul 10 10:34:24 EDT 2025
IsDoiOpenAccess true
IsOpenAccess true
IsPeerReviewed true
IsScholarly true
Issue 1
Language English
License This work is licensed under the Creative Commons Attribution 4.0 Public License.
LinkModel DirectLink
MergedId FETCHMERGED-LOGICAL-d1609-865a217314295ec21ae85a1e9f2654c874fe208b6106c63e21d49297adeb2db43
OpenAccessLink http://journals.scholarsportal.info/openUrl.xqy?doi=10.1515/cdbme-2019-0045
PageCount 4
ParticipantIDs doaj_primary_oai_doaj_org_article_be0b304cf0f74025bdfaf3a387676af5
walterdegruyter_journals_10_1515_cdbme_2019_004551179
PublicationCentury 2000
PublicationDate 2019-09-01
PublicationDateYYYYMMDD 2019-09-01
PublicationDate_xml – month: 09
  year: 2019
  text: 2019-09-01
  day: 01
PublicationDecade 2010
PublicationTitle Current directions in biomedical engineering
PublicationYear 2019
Publisher De Gruyter
Publisher_xml – name: De Gruyter
SSID ssj0001626683
Score 2.0786965
Snippet Venous blood circulation can be restricted due to various conditions commonly indicating a related medical condition. However, current non-invasive methods for...
SourceID doaj
walterdegruyter
SourceType Open Website
Publisher
StartPage 179
SubjectTerms circulatory system
thermal mass measurement
vascular thrombosis
venous blood flow
SummonAdditionalLinks – databaseName: DOAJ Directory of Open Access Journals
  dbid: DOA
  link: http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwrV3JTsMwELVQT_RQsYqyyQeuUZ3FTnJkVYUEJyr1Zo03hAQtKl3E3zPjBBFx4cItyiXWPDvznj1-w9gFZkhwoVSJMyBQoFCbl2AqfILgnbCZje3bHh7VeFLcT-W00-qLasIae-AmcCPjhUHJbYMIJWodaVyAkEOOq7hUEKJ7qahFR0zF3RXk6arKWy8fzNkj6zC94JygOzuCLi9Fi_4-G2zisbTzz4vV5_L7GDRml7sdNmhpIb9shrPLtvxsj_U7ZoH77KZjiTGf8XngwFG7Jy-zNVANOl9Hu1UeS9F5eJ1v-NvPBiB3nv4JB2xyd_t0PU7aHgiJS5Wok0pJQNWQp5g3pLdZCr6SkPo6ZEoWtiqL4DNRGWRByqrcZ6krkPGU4FAyO1Pkh6yHY_FHjMvSCJ87k0JNfaatIfYFKRQiBF-XcsiuKCT6vbG50GQ8HV8gHLqFQ_8Fx5DJXwHV7aL40KQ3EAododAEhSYoJLnSHf_Hx0_YdgMwlYCdst5ysfJnyBmW5jxOjy8jEsEv
  priority: 102
  providerName: Directory of Open Access Journals
Title Investigation of a non-invasive venous blood flow measurement device
URI https://www.degruyter.com/doi/10.1515/cdbme-2019-0045
https://doaj.org/article/be0b304cf0f74025bdfaf3a387676af5
Volume 5
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1JSwMxGA3aXvRQXHEtOXgdzSzJzBxE6lKLUD1oobeQtQi1o7WL_fd-Sae0SE_ehoEMQ14m33tJ5j2ELqBCCm1TFmgpCAgUF_NiZQZXwhpNVKR8fFv7mbU6yVOXdpdxQGUHfq-Vdi5PqjPsX_58zW7gg7_26T0hvVIaKgfA7X7HAYayiapQlphTYu2S6_sFF6DuLItLe5817UrX_m1Um_qdam16w_FstNgZ9QWnuYNqJVPEjTm0u2jDDPbQ9op_4D66X3HJKAa4sFhgkPPB-2Ai3LF0PPEOrNifTse2X0zxx3JNEGvjpokD1Gk-vN21gjIWIdAhI3mQMSpASMQhlBJqVBQKk1ERmtxGjCYqSxNrIpJJIEZMsdhEoU6ABKVCg4rWMokPUQXexRwhTFNJTKxlKHIXPa2kI2QiFAmx1uQpPUa3rkv459z5gjsvan-jGPZ4ObS5NETGJFGW2BTUKJXaChuLGObZlAkLD6F_OpQvYOZOggAU3EPBHRTcQUGdUd3JP9udoq05pu4g2BmqjIZjcw7MYSTrqNpoPb6-1L3yrvvx8QvIa8X1
linkProvider Scholars Portal
linkToHtml http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV3JTsMwEB1BOUAPFavY8YFrVGexkx5LWcrScqBI3CyvBYk2qLRU_D3jNNAKceIWRXJk-dme95zxG4BTjJDSuJQHRkmKAsWXeXEqwyfprKE60kX5tk6Xtx-Tmyf2tASt77swPq3S2P5o8jmeOaTWTa4n_qDsx2sAI3BdGwwWiLC_gYOkpP48HrwuwwpH-h9VYKXZvnq4nx-1IGnnWVwa-_zRvPTrr0JtWvyj_unAQqi5XIdayRFJcwbqBizZ4SZUF5wDt-B8wR8jH5LcEUlQyAcvww_pE9LJR-G9Soq8dOJe8ykZzE8DibF-g9iGx8uLXqsdlAURAhNy2ggyziRKiDjEIMKsjkJpMyZD23ARZ4nO0sTZiGYKKRHXPLZRaBKkP6k0qJ-NSuIdqGBf7C4QlipqY6NC2fBFp7XyVEyGMqHO2UbK9uDMD4l4m3leCO9CXbzIR31RTmqhLFUxTbSjLkUdypRx0sUyxh025dLhR9ivARXlCnkXXnwgFKKAQngohIeCeYu6_X-2O4HVdq9zJ-6uu7cHsDbD16eDHUJlPJrYI-QPY3Vczo8v1t3EXg
linkToPdf http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1bS8MwGA26gbiH4RXv5sHXsvSStH2czjlvU9CBbyHXIeg65i747_3Slq2IT76VQtqSk-Y7J_lyPoQuIEIKbWPmaSkICBRX5sXKBK6ENZqoQOXl2x77rDeI7t7oW-UsjEur1GY4mX1PC4fUls7UzC2ULb0GIAK3lIZgAQi7EzhASlpjbddRnbE0SGqo3u7dvDytVlqAs7MkLH19_mhd2vU3UHORb1Ev31-JNN0t1CwpIm4XmG6jNTPaQY2KceAu6lTsMbIRziwWGHS89z6aC5ePjue59SrO09Kx_cgW-HO1GIi1cfPDHhp0r1-vel5ZD8HTPiOplzAqQEGEPsQQalTgC5NQ4ZvUBoxGKokjawKSSGBETLHQBL6OgP3EQoN81jIK91ENvsUcIExjSUyopS9SV3NaScfEhC8iYq1JY3qILl2X8HFhecGdCXV-I5sMeTmmuTREhiRSltgYZCiV2gobihAm2JgJCw-hvzqUlz_IF3faA6DgORTcQcEdFNQ51B39s9052njudPnDbf_-GG0W8LpksBNUm05m5hTYw1SelcPjB-luw40
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Investigation+of+a+non-invasive+venous+blood+flow+measurement+device&rft.jtitle=Current+directions+in+biomedical+engineering&rft.au=Stewart%2C+Kent&rft.au=Dangelmaier%2C+Simon&rft.au=Pott%2C+Peter&rft.au=Anders%2C+Jens&rft.date=2019-09-01&rft.pub=De+Gruyter&rft.eissn=2364-5504&rft.volume=5&rft.issue=1&rft.spage=179&rft.epage=182&rft_id=info:doi/10.1515%2Fcdbme-2019-0045&rft.externalDBID=n%2Fa&rft.externalDocID=10_1515_cdbme_2019_004551179