Study on the 241Am-Be neutron reference radiation field established at CAEP

In order to evaluate the field characteristics and instrument calibration capability of the 241Am-Be neutron reference radiation field at China Academy of Engineering Physics (CAEP), this paper conducted a series of researches on the radiation field. Firstly, the neutron energy spectrum of the field...

Full description

Saved in:
Bibliographic Details
Published inRadiation protection dosimetry
Main Authors Zhang, Song, Ding, Da-Jie, Mao, Ben-Jiang, Zhuo, Ren-Hong, Cheng, Jing, Zheng, Hui, Lv, Ji-Lu, Liu, Yi-Xin
Format Journal Article
LanguageEnglish
Published England 15.08.2025
Online AccessGet more information

Cover

Loading…
Abstract In order to evaluate the field characteristics and instrument calibration capability of the 241Am-Be neutron reference radiation field at China Academy of Engineering Physics (CAEP), this paper conducted a series of researches on the radiation field. Firstly, the neutron energy spectrum of the field was investigated by multi-sphere spectrometer and Geant4. Secondly, the quantity transmission from China Institute of Atomic Energy (CIAE) to CAEP was achieved through the precision long counter system. In addition, three neutron dose rate meters from different manufacturers were calibrated in both the fields at CAEP and CIAE. Finally, the uncertainty of calibration factor for each instrument was calculated and validated in the two fields. The results demonstrated that the room scatter in the neutron radiation reference field at CAEP meet the requirement of ISO 8529 and the neutron energy spectrum measured in the field was acceptable. The range of neutron ambient dose equivalent rate that can be produced at CAEP and its uncertainty were determined. The calibration factors and their extended uncertainties obtained using two instruments in both fields were found to be reasonable and reliable. The radiation field established at CAEP can meet the routine calibration and experiment of common neutron dose rate meters.
AbstractList In order to evaluate the field characteristics and instrument calibration capability of the 241Am-Be neutron reference radiation field at China Academy of Engineering Physics (CAEP), this paper conducted a series of researches on the radiation field. Firstly, the neutron energy spectrum of the field was investigated by multi-sphere spectrometer and Geant4. Secondly, the quantity transmission from China Institute of Atomic Energy (CIAE) to CAEP was achieved through the precision long counter system. In addition, three neutron dose rate meters from different manufacturers were calibrated in both the fields at CAEP and CIAE. Finally, the uncertainty of calibration factor for each instrument was calculated and validated in the two fields. The results demonstrated that the room scatter in the neutron radiation reference field at CAEP meet the requirement of ISO 8529 and the neutron energy spectrum measured in the field was acceptable. The range of neutron ambient dose equivalent rate that can be produced at CAEP and its uncertainty were determined. The calibration factors and their extended uncertainties obtained using two instruments in both fields were found to be reasonable and reliable. The radiation field established at CAEP can meet the routine calibration and experiment of common neutron dose rate meters.
Author Lv, Ji-Lu
Zhang, Song
Zheng, Hui
Cheng, Jing
Zhuo, Ren-Hong
Ding, Da-Jie
Mao, Ben-Jiang
Liu, Yi-Xin
Author_xml – sequence: 1
  givenname: Song
  orcidid: 0009-0006-1842-4970
  surname: Zhang
  fullname: Zhang, Song
  organization: Institute of Nuclear Physics and Chemistry, China Academy of Engineering Physics, No. 64, Mianshan Road, Youxian District, Mianyang 621999, Sichuan, China
– sequence: 2
  givenname: Da-Jie
  surname: Ding
  fullname: Ding, Da-Jie
  organization: Institute of Nuclear Physics and Chemistry, China Academy of Engineering Physics, No. 64, Mianshan Road, Youxian District, Mianyang 621999, Sichuan, China
– sequence: 3
  givenname: Ben-Jiang
  surname: Mao
  fullname: Mao, Ben-Jiang
  organization: Institute of Nuclear Physics and Chemistry, China Academy of Engineering Physics, No. 64, Mianshan Road, Youxian District, Mianyang 621999, Sichuan, China
– sequence: 4
  givenname: Ren-Hong
  surname: Zhuo
  fullname: Zhuo, Ren-Hong
  organization: Institute of Nuclear Physics and Chemistry, China Academy of Engineering Physics, No. 64, Mianshan Road, Youxian District, Mianyang 621999, Sichuan, China
– sequence: 5
  givenname: Jing
  surname: Cheng
  fullname: Cheng, Jing
  organization: Institute of Nuclear Physics and Chemistry, China Academy of Engineering Physics, No. 64, Mianshan Road, Youxian District, Mianyang 621999, Sichuan, China
– sequence: 6
  givenname: Hui
  surname: Zheng
  fullname: Zheng, Hui
  organization: Institute of Nuclear Physics and Chemistry, China Academy of Engineering Physics, No. 64, Mianshan Road, Youxian District, Mianyang 621999, Sichuan, China
– sequence: 7
  givenname: Ji-Lu
  surname: Lv
  fullname: Lv, Ji-Lu
  organization: Institute of Nuclear Physics and Chemistry, China Academy of Engineering Physics, No. 64, Mianshan Road, Youxian District, Mianyang 621999, Sichuan, China
– sequence: 8
  givenname: Yi-Xin
  surname: Liu
  fullname: Liu, Yi-Xin
  organization: Institute of Nuclear Physics and Chemistry, China Academy of Engineering Physics, No. 64, Mianshan Road, Youxian District, Mianyang 621999, Sichuan, China
BackLink https://www.ncbi.nlm.nih.gov/pubmed/40814204$$D View this record in MEDLINE/PubMed
BookMark eNo1j89LwzAYQIMo7oeevEv-gbov6Ze2Oc6yqThQcPeRNF9Ypc1Kmh723ztQTw_e4cFbsOtwCsTYg4AnATpfxcGtQmM8aLxic1GizHKEYsYW4_gNIEut8JbNECqBEnDO3r_S5M78FHg6Epco1n32TDzQlOJFRvIUKTTEo3GtSe3F-ZY6x2lMxnbteCTHTeL1evN5x2686Ua6_-OS7bebff2a7T5e3ur1Lmu0xEx57b23KCpvJTRaWF9UTqFApRpnpPZQgKoUKSsq0CXlZV4iFc4hWpCFXLLH3-ww2Z7cYYhtb-L58D8lfwC-aUzW
ContentType Journal Article
Copyright The Author(s) 2025. Published by Oxford University Press. All rights reserved. For commercial re-use, please contact reprints@oup.com for reprints and translation rights for reprints. All other permissions can be obtained through our RightsLink service via the Permissions link on the article page on our site—for further information please contact journals.permissions@oup.com.
Copyright_xml – notice: The Author(s) 2025. Published by Oxford University Press. All rights reserved. For commercial re-use, please contact reprints@oup.com for reprints and translation rights for reprints. All other permissions can be obtained through our RightsLink service via the Permissions link on the article page on our site—for further information please contact journals.permissions@oup.com.
DBID NPM
DOI 10.1093/rpd/ncaf094
DatabaseName PubMed
DatabaseTitle PubMed
DatabaseTitleList PubMed
Database_xml – sequence: 1
  dbid: NPM
  name: PubMed
  url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed
  sourceTypes: Index Database
DeliveryMethod no_fulltext_linktorsrc
Discipline Medicine
EISSN 1742-3406
ExternalDocumentID 40814204
Genre Journal Article
GrantInformation_xml – fundername: National Natural Science Foundation of China
  grantid: 12475320
GroupedDBID ---
-E4
.2P
.I3
.ZR
0R~
123
1TH
29P
4.4
48X
5VS
5WA
5WD
70D
AABZA
AACZT
AAIJN
AAJKP
AAMDB
AAMVS
AAOGV
AAPNW
AAPQZ
AAPXW
AARHZ
AAUAY
AAVAP
ABDFA
ABDTM
ABEJV
ABEUO
ABGNP
ABIXL
ABJNI
ABKDP
ABNHQ
ABNKS
ABPQP
ABPTD
ABQLI
ABQNK
ABVGC
ABWST
ABXVV
ABZBJ
ACGFS
ACUFI
ACUTO
ACUXJ
ACYHN
ACYTK
ADBBV
ADEYI
ADEZT
ADGZP
ADHKW
ADHZD
ADIPN
ADNBA
ADOCK
ADQBN
ADRDM
ADRTK
ADVEK
ADYJX
ADYVW
ADZXQ
AECKG
AEGPL
AEJOX
AEKKA
AEKSI
AEMDU
AEMQT
AENEX
AENZO
AEPUE
AETBJ
AEWNT
AFFZL
AFIYH
AFOFC
AFXAL
AGINJ
AGKEF
AGORE
AGQXC
AGSYK
AGUTN
AHGBF
AHMMS
AHXPO
AIJHB
AJBYB
AJEEA
AJEUX
AJNCP
AKWXX
ALMA_UNASSIGNED_HOLDINGS
ALTZX
ALUQC
ALXQX
ANAKG
APIBT
APWMN
ATGXG
AXUDD
AZVOD
BAYMD
BCRHZ
BEYMZ
BHONS
BQUQU
BTQHN
BTRTY
BVRKM
C45
CDBKE
CS3
CZ4
DAKXR
DILTD
DU5
D~K
EBS
EE~
ENERS
F5P
F9B
FECEO
FLIZI
FLUFQ
FOEOM
FOTVD
FQBLK
GAUVT
GJXCC
H13
H5~
HAR
HW0
HZ~
IOX
J21
JXSIZ
KAQDR
KOP
KSI
KSN
M-Z
MHKGH
N9A
NGC
NMDNZ
NOMLY
NOYVH
NPM
O9-
OAUYM
OAWHX
OCZFY
ODMLO
OJQWA
OJZSN
OPAEJ
OVD
OWPYF
P2P
PAFKI
PEELM
Q1.
Q5Y
RD5
RNS
ROL
ROX
RUSNO
RW1
RXO
TEORI
TJP
TJX
X7H
YAYTL
YKOAZ
YXANX
ZKX
~91
ID FETCH-LOGICAL-c924-5f9fffb418fb20c91bf68d541455cda29f060585e5b18097e37374e6dd44b0262
IngestDate Sat Aug 16 01:30:46 EDT 2025
IsPeerReviewed true
IsScholarly true
Language English
License The Author(s) 2025. Published by Oxford University Press. All rights reserved. For commercial re-use, please contact reprints@oup.com for reprints and translation rights for reprints. All other permissions can be obtained through our RightsLink service via the Permissions link on the article page on our site—for further information please contact journals.permissions@oup.com.
LinkModel OpenURL
MergedId FETCHMERGED-LOGICAL-c924-5f9fffb418fb20c91bf68d541455cda29f060585e5b18097e37374e6dd44b0262
ORCID 0009-0006-1842-4970
PMID 40814204
ParticipantIDs pubmed_primary_40814204
PublicationCentury 2000
PublicationDate 2025-Aug-15
PublicationDateYYYYMMDD 2025-08-15
PublicationDate_xml – month: 08
  year: 2025
  text: 2025-Aug-15
  day: 15
PublicationDecade 2020
PublicationPlace England
PublicationPlace_xml – name: England
PublicationTitle Radiation protection dosimetry
PublicationTitleAlternate Radiat Prot Dosimetry
PublicationYear 2025
SSID ssj0027954
Score 2.4100955
SecondaryResourceType online_first
Snippet In order to evaluate the field characteristics and instrument calibration capability of the 241Am-Be neutron reference radiation field at China Academy of...
SourceID pubmed
SourceType Index Database
Title Study on the 241Am-Be neutron reference radiation field established at CAEP
URI https://www.ncbi.nlm.nih.gov/pubmed/40814204
hasFullText
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnZ1RT9swEMetwaSKFzQGGzCY_MBb5ZKkdhI_FsZUMQ0hKFK1F2QntuChSQXlhU_Pne0kVRkS20sU2Wlk5Zcmd5e7_xFyVMRa5nDrsMxoxXhiFZO5SpnVRSaTWOnIOrXPi3R8w8-nYtr173TVJQs9KJ7_WlfyP1RhDLhilew_kG1PCgOwD3xhC4Rh-y7G114R2mcqwktyNGMnpl-ZJ4xv99sOIv0HFCDwSYWYsNaHN4Hy2fAlFjOejs4ul43Uq_bwoOKAu2X9eD8ziy5ruAs11-Hth_ZwaJHyQ7Hz-6W0WheQPTEVjKru6D93T7VnXLFxc5YQgkgExlR9EebA-McmONhsyJ12wOuHshesepgjhKpQNvJtjZcAzWeOEAf7hCfRO2ZXNLKbqTWyBt4Ctj_FmE3jdkvBQ2UmrOQY1nEcVrFBes0vV7wKZ11MPpHN4BbQkWe8RT6Y6jPp_Q6JD9vkl0NN64oCatqgpgE1bVHTFjV1qOkSaqoWFFHvkMnPs8npmIU-GKwA75gJK621mse51UlUyFjbNC-xfbsQRakSaSP8ti2M0CjGlplhNsy4ScuScw0udvKFrFd1ZXYJTVIteGljsAJznmuTyyySqOjEMdvX2D3y1V-F27nXOrltrs_-mzPfyEZ3TxyQjxb-XOYQLLWF_u5AvAA90ju0
linkProvider National Library of Medicine
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Study+on+the+241Am-Be+neutron+reference+radiation+field+established+at+CAEP&rft.jtitle=Radiation+protection+dosimetry&rft.au=Zhang%2C+Song&rft.au=Ding%2C+Da-Jie&rft.au=Mao%2C+Ben-Jiang&rft.au=Zhuo%2C+Ren-Hong&rft.date=2025-08-15&rft.eissn=1742-3406&rft_id=info:doi/10.1093%2Frpd%2Fncaf094&rft_id=info%3Apmid%2F40814204&rft_id=info%3Apmid%2F40814204&rft.externalDocID=40814204