A scanning electron microscope evaluation of surface roughness of different clear aligners – A comparative in-Vitro study

Clear aligner are thermoplastic polyurethane materials which produces small increments of tooth movements by each aligner tray. Clinical effectiveness of the treatment largely depend on the mechanical properties of the material. The use of scanning electron microscopy (SEM) in invitro environment al...

Full description

Saved in:
Bibliographic Details
Published inIP Indian Journal of Orthodontics and Dentofacial Research Vol. 10; no. 3; pp. 177 - 184
Main Authors Devi, Sumithra, Rajendran, Ramya, Selvaraj, Priyanka, Jeevagan, Sruthi, Reddy, Mora Sathi Rami
Format Journal Article
LanguageEnglish
Published 28.09.2024
Online AccessGet full text

Cover

Loading…
Abstract Clear aligner are thermoplastic polyurethane materials which produces small increments of tooth movements by each aligner tray. Clinical effectiveness of the treatment largely depend on the mechanical properties of the material. The use of scanning electron microscopy (SEM) in invitro environment allows to evaluate the surface morphology of the aligners The aim of the study is to compare the surface roughness of different types of clear aligners after thermoforming and after invitro aging. A sample of 15 aligners from Group A (DURAN), Group B (ERKODUR), Group C (MONOFLEX) were taken for this study. After screening the subjects were scanned by intraoral scanner and STL file were imported to Maestero 3D software. Then resin models were printed and aligners were fabricated in the models by thermoforming machine. The first set of aligners were scanned by Scanning Electron Microscope and another set of aligners were placed in chewing simulator for simulating intraoral environment. Then the second set of aligners were sent for SEM evaluation. Mean comparison of surface roughness and root mean square surface roughness was compared by paired t test and comparison among the groups was done by one way ANOVA test. The surface roughness of both aligners increased after thermoforming. This could be due to thermoforming process which could be due to temperature variation. After the ageing of the aligners in the invitro environment, there is homogenous and smooth layer of the aligner surfaces which could be due to adhesion of biofilm and polishing effect by chewing strokes.
AbstractList Clear aligner are thermoplastic polyurethane materials which produces small increments of tooth movements by each aligner tray. Clinical effectiveness of the treatment largely depend on the mechanical properties of the material. The use of scanning electron microscopy (SEM) in invitro environment allows to evaluate the surface morphology of the aligners The aim of the study is to compare the surface roughness of different types of clear aligners after thermoforming and after invitro aging. A sample of 15 aligners from Group A (DURAN), Group B (ERKODUR), Group C (MONOFLEX) were taken for this study. After screening the subjects were scanned by intraoral scanner and STL file were imported to Maestero 3D software. Then resin models were printed and aligners were fabricated in the models by thermoforming machine. The first set of aligners were scanned by Scanning Electron Microscope and another set of aligners were placed in chewing simulator for simulating intraoral environment. Then the second set of aligners were sent for SEM evaluation. Mean comparison of surface roughness and root mean square surface roughness was compared by paired t test and comparison among the groups was done by one way ANOVA test. The surface roughness of both aligners increased after thermoforming. This could be due to thermoforming process which could be due to temperature variation. After the ageing of the aligners in the invitro environment, there is homogenous and smooth layer of the aligner surfaces which could be due to adhesion of biofilm and polishing effect by chewing strokes.
Author Jeevagan, Sruthi
Devi, Sumithra
Selvaraj, Priyanka
Reddy, Mora Sathi Rami
Rajendran, Ramya
Author_xml – sequence: 1
  givenname: Sumithra
  surname: Devi
  fullname: Devi, Sumithra
  organization: Adhiparasakthi Dental College and Hospital, Melmaruvathur, Tamil Nadu, India
– sequence: 2
  givenname: Ramya
  orcidid: 0000-0002-3109-2310
  surname: Rajendran
  fullname: Rajendran, Ramya
  organization: JKKN Dental College and Hospital, Komarapalayam, Tamil Nadu, India
– sequence: 3
  givenname: Priyanka
  orcidid: 0009-0005-0470-8422
  surname: Selvaraj
  fullname: Selvaraj, Priyanka
  organization: Adhiparasakthi Dental College and Hospital, Melmaruvathur, Tamil Nadu, India
– sequence: 4
  givenname: Sruthi
  orcidid: 0009-0008-4038-5335
  surname: Jeevagan
  fullname: Jeevagan, Sruthi
  organization: Adhiparasakthi Dental College and Hospital, Melmaruvathur, Tamil Nadu, India
– sequence: 5
  givenname: Mora Sathi Rami
  surname: Reddy
  fullname: Reddy, Mora Sathi Rami
  organization: Adhiparasakthi Dental College and Hospital, Melmaruvathur, Tamil Nadu, India
BookMark eNo9kE1qwzAUhEVJoWmaA3SnC9jVj5XYyxD6Ewh0E7oVz_JTquBIQbIDoZveoTfsSeqkpat5DMM85rslIx88EnLPWc5LIfnDLne70MRcMFHkTIorMhaq5FklZ8Xo_1azGzJNydWsKObFkFVj8rGgyYD3zm8ptmi6GDzdOxNDMuGAFI_Q9tC5wQ2Wpj5aMEhj6LfvHlM6m42zFiP6jpoWIVJo3dZjTPT784suqAn7A8Sh4ojU-ezNDS9o6vrmdEeuLbQJp386IZunx83yJVu_Pq-Wi3VmSiUyqIQtsWaysraCOVbKqFLxEoWxlttKSGGaxohaFKbm85ohAAdlUVheKwQ5Ify39jwqRbT6EN0e4klzpi_89E5f-OkzPz3wkz-NY2vT
Cites_doi 10.4041/kjod.2021.51.2.135
10.1016/j.ajodo.2019.05.023
10.2478/aoj-2009-0007
10.1177/14653125221145948
10.1007/s00056-018-00167-1
10.1016/j.bioactmat.2022.10.006
10.1016/j.odw.2006.03.003
10.1016/j.ajodo.2004.04.021
10.3390/ma12152406
10.1186/s40510-019-0289-6
10.1093/ejo/cjv003
10.1016/0002-9416(71)90099-6
10.4041/kjod.2018.48.5.316
10.1186/s12903-020-01233-0
ContentType Journal Article
DBID AAYXX
CITATION
DOI 10.18231/j.ijodr.2024.032
DatabaseName CrossRef
DatabaseTitle CrossRef
DatabaseTitleList CrossRef
DeliveryMethod fulltext_linktorsrc
EISSN 2581-9364
EndPage 184
ExternalDocumentID 10_18231_j_ijodr_2024_032
GroupedDBID AAYXX
CITATION
M~E
ID FETCH-LOGICAL-c852-a92f8eb039ff9a7e95c58518e2cff1f9232cddc2b24cb17b0eaa1a5fe2f1b5ea3
ISSN 2581-9356
IngestDate Tue Jul 01 03:37:23 EDT 2025
IsDoiOpenAccess false
IsOpenAccess true
IsPeerReviewed false
IsScholarly true
Issue 3
Language English
LinkModel OpenURL
MergedId FETCHMERGED-LOGICAL-c852-a92f8eb039ff9a7e95c58518e2cff1f9232cddc2b24cb17b0eaa1a5fe2f1b5ea3
ORCID 0000-0002-3109-2310
0009-0008-4038-5335
0009-0005-0470-8422
OpenAccessLink https://doi.org/10.18231/j.ijodr.2024.032
PageCount 8
ParticipantIDs crossref_primary_10_18231_j_ijodr_2024_032
ProviderPackageCode CITATION
AAYXX
PublicationCentury 2000
PublicationDate 2024-9-28
PublicationDateYYYYMMDD 2024-09-28
PublicationDate_xml – month: 09
  year: 2024
  text: 2024-9-28
  day: 28
PublicationDecade 2020
PublicationTitle IP Indian Journal of Orthodontics and Dentofacial Research
PublicationYear 2024
References ref13
ref12
ref15
ref14
ref11
ref10
ref2
ref1
ref8
ref7
ref9
ref4
ref3
ref6
ref5
References_xml – ident: ref7
  doi: 10.4041/kjod.2021.51.2.135
– ident: ref4
  doi: 10.1016/j.ajodo.2019.05.023
– ident: ref6
  doi: 10.2478/aoj-2009-0007
– ident: ref12
  doi: 10.1177/14653125221145948
– ident: ref8
  doi: 10.1007/s00056-018-00167-1
– ident: ref2
  doi: 10.1016/j.bioactmat.2022.10.006
– ident: ref15
  doi: 10.1016/j.odw.2006.03.003
– ident: ref11
  doi: 10.1016/j.ajodo.2004.04.021
– ident: ref13
  doi: 10.3390/ma12152406
– ident: ref9
  doi: 10.1016/j.ajodo.2004.04.021
– ident: ref10
  doi: 10.1186/s40510-019-0289-6
– ident: ref14
  doi: 10.1093/ejo/cjv003
– ident: ref1
  doi: 10.1016/0002-9416(71)90099-6
– ident: ref3
  doi: 10.4041/kjod.2018.48.5.316
– ident: ref5
  doi: 10.1186/s12903-020-01233-0
SSID ssib044742025
Score 2.269853
Snippet Clear aligner are thermoplastic polyurethane materials which produces small increments of tooth movements by each aligner tray. Clinical effectiveness of the...
SourceID crossref
SourceType Index Database
StartPage 177
Title A scanning electron microscope evaluation of surface roughness of different clear aligners – A comparative in-Vitro study
Volume 10
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1Lb9QwELaWcuGCigDxKvKBE6uUxImTzXEFRaVSoYIF9bayHXubliYoTZAKEuI_8P848EuYcRKvKSBRLlHkRJPHfJqHPf6GkEfKxFlmDGQnXBaQoIQyEJyBQtKiSPNcax7hBuf9l-nu22TvkB9OJt-9qqWuldvq0x_3lfyPVmEM9Iq7ZC-hWScUBuAc9AtH0DAc_0nH8-mZ6nsOTcd2NtNTrLCze008Jm8MCc-6xgiF9YTd6sgaOBgc-6O0U4X9I6YQla8q3NM7FkHEYDmUxxBeVsG7Eh7k8dIOoe2LAzA2lujAC3JfNdiguq4cGfQzeFYN71FaUn9vKg2DaXDSfaUQTvc0zmG8Fse6KpphxUqcnrsrb_T7j_BmdgXqoCnPRXXiru1p-P7VML_bdO1R6c9wsATLMZhnlBmfRUEe84Ey2x_rGdCdJQ89xMaeWY6GVjG9h4_6pnS_OQ9cEbXeozyuC-SKZcl2OMy-_kLUfcGBurJGTKhQCGRUVsQSRSxBxBVylUEagx029r_sjPYuSbIE7sAqW_eJw8I7Snly8UW80MmLgRab5PqgVzrvkXiDTHR1k3ye0xGFdEQhXaOQrlFIa0MHFFKHQhx0KKQWhXREIf3x9RudUw9_dMQftfi7RRbPdxZPd4OhpUegZpwFImdmpmUY58bkItM5V7gsPdNMGRMZSDaYKgrFJEuUjDIZaiEiwY1mJpJci_g22ajqSt8hVIYqjGQRpnkcJ0wnUsDf1CoyqVRhIfRd8nj8WcsPPXHL8q_6uXeZm--Ta2uUPiAbbdPpLYhMW_nQqvcn5BCZEg
linkProvider ISSN International Centre
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=A+scanning+electron+microscope+evaluation+of+surface+roughness+of+different+clear+aligners+%E2%80%93+A+comparative+in-Vitro+study&rft.jtitle=IP+Indian+Journal+of+Orthodontics+and+Dentofacial+Research&rft.au=Devi%2C+Sumithra&rft.au=Rajendran%2C+Ramya&rft.au=Selvaraj%2C+Priyanka&rft.au=Jeevagan%2C+Sruthi&rft.date=2024-09-28&rft.issn=2581-9356&rft.eissn=2581-9364&rft.volume=10&rft.issue=3&rft.spage=177&rft.epage=184&rft_id=info:doi/10.18231%2Fj.ijodr.2024.032&rft.externalDBID=n%2Fa&rft.externalDocID=10_18231_j_ijodr_2024_032
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=2581-9356&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=2581-9356&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=2581-9356&client=summon