A scanning electron microscope evaluation of surface roughness of different clear aligners – A comparative in-Vitro study
Clear aligner are thermoplastic polyurethane materials which produces small increments of tooth movements by each aligner tray. Clinical effectiveness of the treatment largely depend on the mechanical properties of the material. The use of scanning electron microscopy (SEM) in invitro environment al...
Saved in:
Published in | IP Indian Journal of Orthodontics and Dentofacial Research Vol. 10; no. 3; pp. 177 - 184 |
---|---|
Main Authors | , , , , |
Format | Journal Article |
Language | English |
Published |
28.09.2024
|
Online Access | Get full text |
Cover
Loading…
Abstract | Clear aligner are thermoplastic polyurethane materials which produces small increments of tooth movements by each aligner tray. Clinical effectiveness of the treatment largely depend on the mechanical properties of the material. The use of scanning electron microscopy (SEM) in invitro environment allows to evaluate the surface morphology of the aligners
The aim of the study is to compare the surface roughness of different types of clear aligners after thermoforming and after invitro aging.
A sample of 15 aligners from Group A (DURAN), Group B (ERKODUR), Group C (MONOFLEX) were taken for this study. After screening the subjects were scanned by intraoral scanner and STL file were imported to Maestero 3D software. Then resin models were printed and aligners were fabricated in the models by thermoforming machine. The first set of aligners were scanned by Scanning Electron Microscope and another set of aligners were placed in chewing simulator for simulating intraoral environment. Then the second set of aligners were sent for SEM evaluation.
Mean comparison of surface roughness and root mean square surface roughness was compared by paired t test and comparison among the groups was done by one way ANOVA test.
The surface roughness of both aligners increased after thermoforming. This could be due to thermoforming process which could be due to temperature variation. After the ageing of the aligners in the invitro environment, there is homogenous and smooth layer of the aligner surfaces which could be due to adhesion of biofilm and polishing effect by chewing strokes. |
---|---|
AbstractList | Clear aligner are thermoplastic polyurethane materials which produces small increments of tooth movements by each aligner tray. Clinical effectiveness of the treatment largely depend on the mechanical properties of the material. The use of scanning electron microscopy (SEM) in invitro environment allows to evaluate the surface morphology of the aligners
The aim of the study is to compare the surface roughness of different types of clear aligners after thermoforming and after invitro aging.
A sample of 15 aligners from Group A (DURAN), Group B (ERKODUR), Group C (MONOFLEX) were taken for this study. After screening the subjects were scanned by intraoral scanner and STL file were imported to Maestero 3D software. Then resin models were printed and aligners were fabricated in the models by thermoforming machine. The first set of aligners were scanned by Scanning Electron Microscope and another set of aligners were placed in chewing simulator for simulating intraoral environment. Then the second set of aligners were sent for SEM evaluation.
Mean comparison of surface roughness and root mean square surface roughness was compared by paired t test and comparison among the groups was done by one way ANOVA test.
The surface roughness of both aligners increased after thermoforming. This could be due to thermoforming process which could be due to temperature variation. After the ageing of the aligners in the invitro environment, there is homogenous and smooth layer of the aligner surfaces which could be due to adhesion of biofilm and polishing effect by chewing strokes. |
Author | Jeevagan, Sruthi Devi, Sumithra Selvaraj, Priyanka Reddy, Mora Sathi Rami Rajendran, Ramya |
Author_xml | – sequence: 1 givenname: Sumithra surname: Devi fullname: Devi, Sumithra organization: Adhiparasakthi Dental College and Hospital, Melmaruvathur, Tamil Nadu, India – sequence: 2 givenname: Ramya orcidid: 0000-0002-3109-2310 surname: Rajendran fullname: Rajendran, Ramya organization: JKKN Dental College and Hospital, Komarapalayam, Tamil Nadu, India – sequence: 3 givenname: Priyanka orcidid: 0009-0005-0470-8422 surname: Selvaraj fullname: Selvaraj, Priyanka organization: Adhiparasakthi Dental College and Hospital, Melmaruvathur, Tamil Nadu, India – sequence: 4 givenname: Sruthi orcidid: 0009-0008-4038-5335 surname: Jeevagan fullname: Jeevagan, Sruthi organization: Adhiparasakthi Dental College and Hospital, Melmaruvathur, Tamil Nadu, India – sequence: 5 givenname: Mora Sathi Rami surname: Reddy fullname: Reddy, Mora Sathi Rami organization: Adhiparasakthi Dental College and Hospital, Melmaruvathur, Tamil Nadu, India |
BookMark | eNo9kE1qwzAUhEVJoWmaA3SnC9jVj5XYyxD6Ewh0E7oVz_JTquBIQbIDoZveoTfsSeqkpat5DMM85rslIx88EnLPWc5LIfnDLne70MRcMFHkTIorMhaq5FklZ8Xo_1azGzJNydWsKObFkFVj8rGgyYD3zm8ptmi6GDzdOxNDMuGAFI_Q9tC5wQ2Wpj5aMEhj6LfvHlM6m42zFiP6jpoWIVJo3dZjTPT784suqAn7A8Sh4ojU-ezNDS9o6vrmdEeuLbQJp386IZunx83yJVu_Pq-Wi3VmSiUyqIQtsWaysraCOVbKqFLxEoWxlttKSGGaxohaFKbm85ohAAdlUVheKwQ5Ify39jwqRbT6EN0e4klzpi_89E5f-OkzPz3wkz-NY2vT |
Cites_doi | 10.4041/kjod.2021.51.2.135 10.1016/j.ajodo.2019.05.023 10.2478/aoj-2009-0007 10.1177/14653125221145948 10.1007/s00056-018-00167-1 10.1016/j.bioactmat.2022.10.006 10.1016/j.odw.2006.03.003 10.1016/j.ajodo.2004.04.021 10.3390/ma12152406 10.1186/s40510-019-0289-6 10.1093/ejo/cjv003 10.1016/0002-9416(71)90099-6 10.4041/kjod.2018.48.5.316 10.1186/s12903-020-01233-0 |
ContentType | Journal Article |
DBID | AAYXX CITATION |
DOI | 10.18231/j.ijodr.2024.032 |
DatabaseName | CrossRef |
DatabaseTitle | CrossRef |
DatabaseTitleList | CrossRef |
DeliveryMethod | fulltext_linktorsrc |
EISSN | 2581-9364 |
EndPage | 184 |
ExternalDocumentID | 10_18231_j_ijodr_2024_032 |
GroupedDBID | AAYXX CITATION M~E |
ID | FETCH-LOGICAL-c852-a92f8eb039ff9a7e95c58518e2cff1f9232cddc2b24cb17b0eaa1a5fe2f1b5ea3 |
ISSN | 2581-9356 |
IngestDate | Tue Jul 01 03:37:23 EDT 2025 |
IsDoiOpenAccess | false |
IsOpenAccess | true |
IsPeerReviewed | false |
IsScholarly | true |
Issue | 3 |
Language | English |
LinkModel | OpenURL |
MergedId | FETCHMERGED-LOGICAL-c852-a92f8eb039ff9a7e95c58518e2cff1f9232cddc2b24cb17b0eaa1a5fe2f1b5ea3 |
ORCID | 0000-0002-3109-2310 0009-0008-4038-5335 0009-0005-0470-8422 |
OpenAccessLink | https://doi.org/10.18231/j.ijodr.2024.032 |
PageCount | 8 |
ParticipantIDs | crossref_primary_10_18231_j_ijodr_2024_032 |
ProviderPackageCode | CITATION AAYXX |
PublicationCentury | 2000 |
PublicationDate | 2024-9-28 |
PublicationDateYYYYMMDD | 2024-09-28 |
PublicationDate_xml | – month: 09 year: 2024 text: 2024-9-28 day: 28 |
PublicationDecade | 2020 |
PublicationTitle | IP Indian Journal of Orthodontics and Dentofacial Research |
PublicationYear | 2024 |
References | ref13 ref12 ref15 ref14 ref11 ref10 ref2 ref1 ref8 ref7 ref9 ref4 ref3 ref6 ref5 |
References_xml | – ident: ref7 doi: 10.4041/kjod.2021.51.2.135 – ident: ref4 doi: 10.1016/j.ajodo.2019.05.023 – ident: ref6 doi: 10.2478/aoj-2009-0007 – ident: ref12 doi: 10.1177/14653125221145948 – ident: ref8 doi: 10.1007/s00056-018-00167-1 – ident: ref2 doi: 10.1016/j.bioactmat.2022.10.006 – ident: ref15 doi: 10.1016/j.odw.2006.03.003 – ident: ref11 doi: 10.1016/j.ajodo.2004.04.021 – ident: ref13 doi: 10.3390/ma12152406 – ident: ref9 doi: 10.1016/j.ajodo.2004.04.021 – ident: ref10 doi: 10.1186/s40510-019-0289-6 – ident: ref14 doi: 10.1093/ejo/cjv003 – ident: ref1 doi: 10.1016/0002-9416(71)90099-6 – ident: ref3 doi: 10.4041/kjod.2018.48.5.316 – ident: ref5 doi: 10.1186/s12903-020-01233-0 |
SSID | ssib044742025 |
Score | 2.269853 |
Snippet | Clear aligner are thermoplastic polyurethane materials which produces small increments of tooth movements by each aligner tray. Clinical effectiveness of the... |
SourceID | crossref |
SourceType | Index Database |
StartPage | 177 |
Title | A scanning electron microscope evaluation of surface roughness of different clear aligners – A comparative in-Vitro study |
Volume | 10 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1Lb9QwELaWcuGCigDxKvKBE6uUxImTzXEFRaVSoYIF9bayHXubliYoTZAKEuI_8P848EuYcRKvKSBRLlHkRJPHfJqHPf6GkEfKxFlmDGQnXBaQoIQyEJyBQtKiSPNcax7hBuf9l-nu22TvkB9OJt-9qqWuldvq0x_3lfyPVmEM9Iq7ZC-hWScUBuAc9AtH0DAc_0nH8-mZ6nsOTcd2NtNTrLCze008Jm8MCc-6xgiF9YTd6sgaOBgc-6O0U4X9I6YQla8q3NM7FkHEYDmUxxBeVsG7Eh7k8dIOoe2LAzA2lujAC3JfNdiguq4cGfQzeFYN71FaUn9vKg2DaXDSfaUQTvc0zmG8Fse6KpphxUqcnrsrb_T7j_BmdgXqoCnPRXXiru1p-P7VML_bdO1R6c9wsATLMZhnlBmfRUEe84Ey2x_rGdCdJQ89xMaeWY6GVjG9h4_6pnS_OQ9cEbXeozyuC-SKZcl2OMy-_kLUfcGBurJGTKhQCGRUVsQSRSxBxBVylUEagx029r_sjPYuSbIE7sAqW_eJw8I7Snly8UW80MmLgRab5PqgVzrvkXiDTHR1k3ye0xGFdEQhXaOQrlFIa0MHFFKHQhx0KKQWhXREIf3x9RudUw9_dMQftfi7RRbPdxZPd4OhpUegZpwFImdmpmUY58bkItM5V7gsPdNMGRMZSDaYKgrFJEuUjDIZaiEiwY1mJpJci_g22ajqSt8hVIYqjGQRpnkcJ0wnUsDf1CoyqVRhIfRd8nj8WcsPPXHL8q_6uXeZm--Ta2uUPiAbbdPpLYhMW_nQqvcn5BCZEg |
linkProvider | ISSN International Centre |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=A+scanning+electron+microscope+evaluation+of+surface+roughness+of+different+clear+aligners+%E2%80%93+A+comparative+in-Vitro+study&rft.jtitle=IP+Indian+Journal+of+Orthodontics+and+Dentofacial+Research&rft.au=Devi%2C+Sumithra&rft.au=Rajendran%2C+Ramya&rft.au=Selvaraj%2C+Priyanka&rft.au=Jeevagan%2C+Sruthi&rft.date=2024-09-28&rft.issn=2581-9356&rft.eissn=2581-9364&rft.volume=10&rft.issue=3&rft.spage=177&rft.epage=184&rft_id=info:doi/10.18231%2Fj.ijodr.2024.032&rft.externalDBID=n%2Fa&rft.externalDocID=10_18231_j_ijodr_2024_032 |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=2581-9356&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=2581-9356&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=2581-9356&client=summon |