Effect of the Cone Heater Scale Compliant with the ISO 5660 Standard on Spatial Uniformity of Radiant Heat Flux
Physical quantities such as mass loss rate, heat release rate, and total heat release are often measured through a cone calorimeter (a representative bench-scale apparatus) and are primarily considered as values per unit area. Hence, the uniformity of radiant heat flux supplied by the cone heater to...
Saved in:
Published in | Fire Science and Engineering Vol. 34; no. 5; pp. 27 - 33 |
---|---|
Main Authors | , , |
Format | Journal Article |
Language | English |
Published |
31.10.2020
|
Online Access | Get full text |
ISSN | 1738-7167 2508-6804 |
DOI | 10.7731/KIFSE.ad1befcd |
Cover
Abstract | Physical quantities such as mass loss rate, heat release rate, and total heat release are often measured through a cone calorimeter (a representative bench-scale apparatus) and are primarily considered as values per unit area. Hence, the uniformity of radiant heat flux supplied by the cone heater to the specimen is very important with respect to the measurement results’ validity. In this study, on the basis of the ISO 5660 standard, the uniformity of radiant heat flux at the specimen surface was evaluated for the cone heaters used with the cone calorimeter. It is observed that a normal cone heater (NCH) compliant with the ISO 5660-1 standard satisfies the requirement of uniformity within a range of ± 2% in the central 5 cm × 5 cm area, but it has a large deviation of approximately 13% at the position corresponding to the edge of the specimen. In addition, the duration of NCH usage does not significantly affect the distribution of radiant heat flux. Furthermore, it is observed that a large cone heater compliant with the ISO/TC 5660-4 standard can supply moderately-uniform radiant heat flux over the entire surface area (10 cm × 10 cm) of the specimen. |
---|---|
AbstractList | Physical quantities such as mass loss rate, heat release rate, and total heat release are often measured through a cone calorimeter (a representative bench-scale apparatus) and are primarily considered as values per unit area. Hence, the uniformity of radiant heat flux supplied by the cone heater to the specimen is very important with respect to the measurement results’ validity. In this study, on the basis of the ISO 5660 standard, the uniformity of radiant heat flux at the specimen surface was evaluated for the cone heaters used with the cone calorimeter. It is observed that a normal cone heater (NCH) compliant with the ISO 5660-1 standard satisfies the requirement of uniformity within a range of ± 2% in the central 5 cm × 5 cm area, but it has a large deviation of approximately 13% at the position corresponding to the edge of the specimen. In addition, the duration of NCH usage does not significantly affect the distribution of radiant heat flux. Furthermore, it is observed that a large cone heater compliant with the ISO/TC 5660-4 standard can supply moderately-uniform radiant heat flux over the entire surface area (10 cm × 10 cm) of the specimen. |
Author | Hwang, Cheol-Hong Ryu, Sanghoon Mun, Sun-Yeo |
Author_xml | – sequence: 1 givenname: Sanghoon surname: Ryu fullname: Ryu, Sanghoon – sequence: 2 givenname: Sun-Yeo surname: Mun fullname: Mun, Sun-Yeo – sequence: 3 givenname: Cheol-Hong surname: Hwang fullname: Hwang, Cheol-Hong |
BookMark | eNo1kF1LwzAYhYNMcM7dep0_0Jk0zZv0UsbqhoOBndclzQcL9GOkEd2_d-306sDhnOfieUSzru8sQs-UrIRg9OV9V5SblTK0tk6bOzRPOZEJSJLN0JwKJhNBQTyg5TD4mmTZtUk5n6N-45zVEfcOx5PF6ysVb62KNuBSq2Zs2nPjVRfxt4-nabQrD5gDEFxG1RkVDO47XJ5V9KrBn513fWh9vIzMD2Wm74jERfP184TunWoGu_zLBToWm-N6m-wPb7v16z7RIjeJYaTOOWS1y4gGK3NJtCE5Z05DJkEDCJfW3IK2WmpqnGVcGJOCoZQLqNkCrW5YHfphCNZV5-BbFS4VJdUorJqEVf_C2C8dnGHk |
Cites_doi | 10.1016/S0379-7112(96)00025-2 10.1016/j.polymdegradstab.2004.12.016 10.1002/fam.949 10.1016/j.combustflame.2011.01.008 10.1016/j.firesaf.2012.03.003 10.1002/fam.810150205 10.1002/fam.1066 10.1016/j.ijheatmasstransfer.2015.09.067 |
ContentType | Journal Article |
DBID | AAYXX CITATION |
DOI | 10.7731/KIFSE.ad1befcd |
DatabaseName | CrossRef |
DatabaseTitle | CrossRef |
DatabaseTitleList | CrossRef |
DeliveryMethod | fulltext_linktorsrc |
EISSN | 2508-6804 |
EndPage | 33 |
ExternalDocumentID | 10_7731_KIFSE_ad1befcd |
GroupedDBID | AAYXX ALMA_UNASSIGNED_HOLDINGS CITATION M~E |
ID | FETCH-LOGICAL-c79d-d30b9564bf40c6e8980cd0953fc6486c667f2b5e6cec8c1dfe357dd26d11576b3 |
ISSN | 1738-7167 |
IngestDate | Tue Jul 01 03:43:16 EDT 2025 |
IsDoiOpenAccess | false |
IsOpenAccess | true |
IsPeerReviewed | false |
IsScholarly | false |
Issue | 5 |
Language | English |
LinkModel | OpenURL |
MergedId | FETCHMERGED-LOGICAL-c79d-d30b9564bf40c6e8980cd0953fc6486c667f2b5e6cec8c1dfe357dd26d11576b3 |
OpenAccessLink | http://www.kifsejournal.or.kr/upload/pdf/KIFSE-ad1befcd.pdf |
PageCount | 7 |
ParticipantIDs | crossref_primary_10_7731_KIFSE_ad1befcd |
ProviderPackageCode | CITATION AAYXX |
PublicationCentury | 2000 |
PublicationDate | 2020-10-31 |
PublicationDateYYYYMMDD | 2020-10-31 |
PublicationDate_xml | – month: 10 year: 2020 text: 2020-10-31 day: 31 |
PublicationDecade | 2020 |
PublicationTitle | Fire Science and Engineering |
PublicationYear | 2020 |
References | (ref2) 2015 ref7 Wilson (ref8) 2003 ref12 ref9 ref4 (ref1) 2015 ref3 ref6 ref5 ref10 (ref11) 2020 |
References_xml | – year: 2020 ident: ref11 – ident: ref6 doi: 10.1016/S0379-7112(96)00025-2 – year: 2015 ident: ref1 – start-page: 815 year: 2003 ident: ref8 – year: 2015 ident: ref2 – ident: ref5 doi: 10.1016/j.polymdegradstab.2004.12.016 – ident: ref4 doi: 10.1002/fam.949 – ident: ref10 doi: 10.1016/j.combustflame.2011.01.008 – ident: ref9 doi: 10.1016/j.firesaf.2012.03.003 – ident: ref3 doi: 10.1002/fam.810150205 – ident: ref7 doi: 10.1002/fam.1066 – ident: ref12 doi: 10.1016/j.ijheatmasstransfer.2015.09.067 |
SSID | ssib044738255 ssib006781895 ssib012146351 ssib016698144 ssib005300067 |
Score | 1.7413011 |
Snippet | Physical quantities such as mass loss rate, heat release rate, and total heat release are often measured through a cone calorimeter (a representative... |
SourceID | crossref |
SourceType | Index Database |
StartPage | 27 |
Title | Effect of the Cone Heater Scale Compliant with the ISO 5660 Standard on Spatial Uniformity of Radiant Heat Flux |
Volume | 34 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1Lb9QwELaWcuGCQIB4ywckDpVLsnFs54hWu1pACxJdpHJa1S-KVCVVlYiWA0d-NzO286DqoXCJVlYyynq-fP48Y48JeaUKB0KgEkwprxnnRjHllGe-sqWC4VpZi_GOzUex_sLfH5VHs9nvyaqlrtUH5ue1-0r-x6vQBn7FXbL_4NnBKDTAb_AvXMHDcL2Rj1Pp4ZTmXzQgGNfAre4cPlkg_vCxYxijTeFWXCh5-GkftFWGKjPGEJAwcFk1-AoEKGrYtErjcyhb0AaT-6vT7mIqZFdAlQMxYPB9UthwSOJcdjHoXH87acZ0_6aLMdeuZl9dM-DqR4pcL05cc8rWTbKTIhIw_RypPJKoBBKFeVgcSF1oA6WlmFDxqOGeeVMY8_s0tx1pVE4G5Fgo4yrVS1kg1X94tzpcHhzbXDtv7Dio9Yn8K2PdsAIR5j5oYRee3_XP3yK351KGdP_m13LCU2FUH3lKgswZ9zPneDh6MWZXcyEqlY-yiXPokHk4gHfomlg_FF_hzd9_YaKPJkJne4_cTTMU-jbC7T6ZufoBaSLUaOMpoIgi1GiEGg1QowPUKEIt3ARQowg12kONNjVNUKMj1NBmglowSRFqD8l2tdwu1iyd1cGMrCyzRaZhps2155kRTlUqMxZLGXojuBJGCOnnunTCOKNMbr0rSmntXFgs9iR08Yjs1fDqjwk1UonsGDpMg9ItKqE5sIify1JXglvhnpDXfQftzmJFlt313nx64zufkTsjkJ-Tvfa8cy9AbLb6ZUDCH02Fexg |
linkProvider | ISSN International Centre |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Effect+of+the+Cone+Heater+Scale+Compliant+with+the+ISO+5660+Standard+on+Spatial+Uniformity+of+Radiant+Heat+Flux&rft.jtitle=Fire+Science+and+Engineering&rft.au=Ryu%2C+Sanghoon&rft.au=Mun%2C+Sun-Yeo&rft.au=Hwang%2C+Cheol-Hong&rft.date=2020-10-31&rft.issn=1738-7167&rft.eissn=2508-6804&rft.volume=34&rft.issue=5&rft.spage=27&rft.epage=33&rft_id=info:doi/10.7731%2FKIFSE.ad1befcd&rft.externalDBID=n%2Fa&rft.externalDocID=10_7731_KIFSE_ad1befcd |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1738-7167&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1738-7167&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1738-7167&client=summon |