Evaluation of ultraviolet-C lamps sterilization in veterinary operating theatre

Ultraviolet (UV) lamp is the simplest method for sterilizing operating theatre. This method is effective, easily operated, and does not require high cost. Furthermore, there were several studies of microorganism contamination in the air and surface at human operating theatre. However, studies in vet...

Full description

Saved in:
Bibliographic Details
Published inARSHI Veterinary Letters Vol. 3; no. 4; pp. 75 - 76
Main Authors Anggoro, Dito, Budhi, Setyo, Purnomo, Agus, Megarani, Dorothea Vera
Format Journal Article
LanguageEnglish
Published 29.11.2019
Online AccessGet full text

Cover

Loading…
Abstract Ultraviolet (UV) lamp is the simplest method for sterilizing operating theatre. This method is effective, easily operated, and does not require high cost. Furthermore, there were several studies of microorganism contamination in the air and surface at human operating theatre. However, studies in veterinary operating theatre related to the effectiveness of UV light on sterilization process is still limited, especially in Indonesia. Bacterial contamination samples were collected three times each in three different conditions: A) before surgery and without UV, B) before surgery but UV was already used, and C) after surgery and UV was already used. Samples were taken with settle plate and swab method for collecting the air and operating table contamination, respectively. One-way repeated measures ANOVA determined that there was statistically significant difference in the number of bacterial contaminations between three conditions (A, B, and C) in settle plate method (p=0.009), as well as in swab method (p=0.010). The result revealed that the UV light was effective to sterilize operating theatre, which can be seen from the significant decreases on the number of bacterial contaminations before and after the UV was used, both in settle plate and swab method. The result of this study supported the theory that the UV light can reduce the air bacterial and surface contamination at operating theatre. However, the result of microorganism contaminations in this study was still not appropriate based on the standard minimum of total bacterial in the operating theatre from The Ministry of Health, Republic of Indonesia. Consequently, the use of another method of sterilization at the operating theatre is still required for a better sterilization result.
AbstractList Ultraviolet (UV) lamp is the simplest method for sterilizing operating theatre. This method is effective, easily operated, and does not require high cost. Furthermore, there were several studies of microorganism contamination in the air and surface at human operating theatre. However, studies in veterinary operating theatre related to the effectiveness of UV light on sterilization process is still limited, especially in Indonesia. Bacterial contamination samples were collected three times each in three different conditions: A) before surgery and without UV, B) before surgery but UV was already used, and C) after surgery and UV was already used. Samples were taken with settle plate and swab method for collecting the air and operating table contamination, respectively. One-way repeated measures ANOVA determined that there was statistically significant difference in the number of bacterial contaminations between three conditions (A, B, and C) in settle plate method (p=0.009), as well as in swab method (p=0.010). The result revealed that the UV light was effective to sterilize operating theatre, which can be seen from the significant decreases on the number of bacterial contaminations before and after the UV was used, both in settle plate and swab method. The result of this study supported the theory that the UV light can reduce the air bacterial and surface contamination at operating theatre. However, the result of microorganism contaminations in this study was still not appropriate based on the standard minimum of total bacterial in the operating theatre from The Ministry of Health, Republic of Indonesia. Consequently, the use of another method of sterilization at the operating theatre is still required for a better sterilization result.
Author Purnomo, Agus
Anggoro, Dito
Budhi, Setyo
Megarani, Dorothea Vera
Author_xml – sequence: 1
  givenname: Dito
  surname: Anggoro
  fullname: Anggoro, Dito
– sequence: 2
  givenname: Setyo
  surname: Budhi
  fullname: Budhi, Setyo
– sequence: 3
  givenname: Agus
  surname: Purnomo
  fullname: Purnomo, Agus
– sequence: 4
  givenname: Dorothea Vera
  surname: Megarani
  fullname: Megarani, Dorothea Vera
BookMark eNpNkE1LxDAYhIOs4Lru1XP-QGq-0x6lrB-wsJe9hzS-1UA2LUm3oL_e6nrwNMPDMAxzi1ZpSIDQPaMVb7iUD26OlahkZRQx-gqtuaoZ4ZLp1T9_g7alhI5KaQQVDV2jw2528eymMCQ89Pgcp-zmMESYSIujO40FlwlyiOHrEgoJz_BDksufeBghLzy94-kD3JThDl33LhbY_ukGHZ92x_aF7A_Pr-3jnnjTaKKo0m-N5qCdcrJmzgDvvVcGWKdBgvHMe6M99doz6bxouGddXdOei57XXGxQdan1eSglQ2_HHE7LIsuo_T3ELodYYaU1yhotvgFPAVfD
Cites_doi 10.2106/JBJS.N.00523
10.12944/CWE.8.2.03
10.1186/1471-2334-6-130
ContentType Journal Article
DBID AAYXX
CITATION
DOI 10.29244/avl.3.4.75-76
DatabaseName CrossRef
DatabaseTitle CrossRef
DatabaseTitleList CrossRef
DeliveryMethod fulltext_linktorsrc
EISSN 2581-2416
EndPage 76
ExternalDocumentID 10_29244_avl_3_4_75_76
GroupedDBID AAYXX
CITATION
ID FETCH-LOGICAL-c796-5056d962e6a5a481a7e2fcc57e1b6e4e7c1cc76c0c6c14ac392c1b880f23f2823
ISSN 2581-2416
IngestDate Fri Aug 23 03:01:35 EDT 2024
IsDoiOpenAccess false
IsOpenAccess true
IsPeerReviewed false
IsScholarly false
Issue 4
Language English
LinkModel OpenURL
MergedId FETCHMERGED-LOGICAL-c796-5056d962e6a5a481a7e2fcc57e1b6e4e7c1cc76c0c6c14ac392c1b880f23f2823
OpenAccessLink https://doi.org/10.29244/avl.3.4.75-76
PageCount 2
ParticipantIDs crossref_primary_10_29244_avl_3_4_75_76
PublicationCentury 2000
PublicationDate 2019-11-29
PublicationDateYYYYMMDD 2019-11-29
PublicationDate_xml – month: 11
  year: 2019
  text: 2019-11-29
  day: 29
PublicationDecade 2010
PublicationTitle ARSHI Veterinary Letters
PublicationYear 2019
References 121115
121114
121117
121116
References_xml – ident: 121117
  doi: 10.2106/JBJS.N.00523
– ident: 121114
  doi: 10.12944/CWE.8.2.03
– ident: 121116
  doi: 10.1186/1471-2334-6-130
– ident: 121115
SSID ssib044730390
ssib044769527
Score 1.7560481
Snippet Ultraviolet (UV) lamp is the simplest method for sterilizing operating theatre. This method is effective, easily operated, and does not require high cost....
SourceID crossref
SourceType Aggregation Database
StartPage 75
Title Evaluation of ultraviolet-C lamps sterilization in veterinary operating theatre
Volume 3
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV3Pb9MwFLbKuHBBTID4OfmAxKFyqRP_yrHaOhWkAoKCdoscx6kmdUkV0klw2N_Oc-wl6dTD4BK1T6nb5H39_J7j7z2E3lE5lSaRlFjLFWGiUEQVeUyUnkrIHgzN22r7y89i8YN9uuAXo9HNUF3SZBPz56Cu5H-8Cjbwq1PJ_oNnu0HBAK_Bv3AED8PxXj6ed6W6Xcy32zS1bh-0N-R0DJ7e_hq7MgiXm6C1dGsb1277i9fgVltXUDnIpXRT720Kmn37vvg4_tmf7XU_XQQ-K9frymtkzoAUuqx-l7ddgoGDmt-d9StcS3XlBTXrXTfG0q517XtKQSBfOy2Yhq-s9XApgiZOkxfWK1rGirgCA6OhtvUBW6DceIAsNqBP30QlTMS-L8xdio8gYWRuArveTOIJm0hO5IFa2nfmuG7nIeQ87QgpfD6NU5ZKnkrxAD2MgKjclsDlzfyWjxgD-ov7p4jwXiS-C3B3Vb4OaDvkh72fNIhzBgHL6gl6HDINPPOwOUYjWz5FX3rI4KrAe5DBLWTwHmTwZYl7yOAOMjhA5hlanc9XpwsSemoQIxNBXLybJyKyQnPNFNXSRoUxXFqaCcss_DmNkcJMjTCUaQPRs6EZcHwRxQVk5_FzdFRWpX2BsOQs1lkurEoyxpVVLIEJgQleCFfIS7xE729vQLr1lVPSw3f_1b3PfI0e9bh7g46aemffQlDYZCet5_4CuSdjzw
link.rule.ids 315,783,787,27938,27939
linkProvider ISSN International Centre
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Evaluation+of+ultraviolet-C+lamps+sterilization+in+veterinary+operating+theatre&rft.jtitle=ARSHI+Veterinary+Letters&rft.au=Anggoro%2C+Dito&rft.au=Budhi%2C+Setyo&rft.au=Purnomo%2C+Agus&rft.au=Megarani%2C+Dorothea+Vera&rft.date=2019-11-29&rft.issn=2581-2416&rft.eissn=2581-2416&rft.volume=3&rft.issue=4&rft.spage=75&rft.epage=76&rft_id=info:doi/10.29244%2Favl.3.4.75-76&rft.externalDBID=n%2Fa&rft.externalDocID=10_29244_avl_3_4_75_76
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=2581-2416&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=2581-2416&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=2581-2416&client=summon