A novel improved combined Dynamic Voltage Restorer (DVR) using Fault Current Limiter (FCL) structure
The dynamic voltage restorer (DVR) as a means of series compensation for mitigating the effect of voltage sags has been established as a preferred approach for improving power quality at sensitive load locations. In this paper a novel structure for voltage sags mitigation and for power quality impro...
Saved in:
Published in | 2007 International Conference on Electrical Machines and Systems (ICEMS) pp. 98 - 101 |
---|---|
Main Authors | , , |
Format | Conference Proceeding |
Language | English |
Published |
IEEE
01.10.2007
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Abstract | The dynamic voltage restorer (DVR) as a means of series compensation for mitigating the effect of voltage sags has been established as a preferred approach for improving power quality at sensitive load locations. In this paper a novel structure for voltage sags mitigation and for power quality improvement are proposed. Considering this fact that for rejection of high order harmonics we have to use DVRs with high-speed switches, therefore increasing the rating required for energy storage device and the need to use high-speed switches in DVRs results in a considerable increasing in costs of this equipments. So in this paper a low power DVR with low-speed switches for decreasing costs are proposed. In presented structure, the combination of FCL and DVR for decreasing the requested power rating and time response of abnormal variations at DVRs are proposed. The proposed structure operation is investigated through computer simulation by using PSCAD/EMTDC. |
---|---|
AbstractList | The dynamic voltage restorer (DVR) as a means of series compensation for mitigating the effect of voltage sags has been established as a preferred approach for improving power quality at sensitive load locations. In this paper a novel structure for voltage sags mitigation and for power quality improvement are proposed. Considering this fact that for rejection of high order harmonics we have to use DVRs with high-speed switches, therefore increasing the rating required for energy storage device and the need to use high-speed switches in DVRs results in a considerable increasing in costs of this equipments. So in this paper a low power DVR with low-speed switches for decreasing costs are proposed. In presented structure, the combination of FCL and DVR for decreasing the requested power rating and time response of abnormal variations at DVRs are proposed. The proposed structure operation is investigated through computer simulation by using PSCAD/EMTDC. |
Author | Hosseini, S.H. Sabahi, M. Abapour, M. |
Author_xml | – sequence: 1 givenname: S.H. surname: Hosseini fullname: Hosseini, S.H. email: hosseini@tabrizu.ac.ir organization: Center of Excellence for Mechatronics, University of Tabriz, Iran – sequence: 2 givenname: M. surname: Abapour fullname: Abapour, M. organization: Faculty of Electrical and Computer Engineering, University of Tabriz, Iran – sequence: 3 givenname: M. surname: Sabahi fullname: Sabahi, M. organization: Faculty of Electrical and Computer Engineering, University of Tabriz, Iran |
BookMark | eNotj0Frg0AUhLfQHpq0v6CH7rE5mPp0dd8eg4ltwFJIQ65h1WdY0DWsayH_vobmNN8Mw8DM2L3tLTH2CuESIFTv22zz9QORFOkyCkO5FAIiEHjHZqgwTWDK4kdWr7jtf6nlpju7CWpe9V1p7ATri9Wdqfihb70-Ed_R4HtHjr-tD7sFHwdjTzzXY-t5NjpH1vPCdMZfG3lWLPjg3Vj50dETe2h0O9DzTedsn2_22WdQfH9ss1URVFJgADJERZAgVUIl0ICYnIqTplZRqBtRkcC4RJ3IMlVxjTJpECOJJSkEUGk8Zy__s4aIjmdnOu0ux9vv-A_YElHD |
CitedBy_id | crossref_primary_10_1109_TPEL_2008_2004496 |
ContentType | Conference Proceeding |
DBID | 6IE 6IL CBEJK RIE RIL |
DOI | 10.1109/ICEMS12746.2007.4412148 |
DatabaseName | IEEE Electronic Library (IEL) Conference Proceedings IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume IEEE Xplore All Conference Proceedings IEEE Electronic Library Online IEEE Proceedings Order Plans (POP All) 1998-Present |
DatabaseTitleList | |
Database_xml | – sequence: 1 dbid: RIE name: IEEE Electronic Library Online url: https://proxy.k.utb.cz/login?url=https://ieeexplore.ieee.org/ sourceTypes: Publisher |
DeliveryMethod | fulltext_linktorsrc |
EISBN | 8986510073 9788986510072 |
EndPage | 101 |
ExternalDocumentID | 4412148 |
Genre | orig-research |
GroupedDBID | 6IE 6IL CBEJK RIE RIL |
ID | FETCH-LOGICAL-c748-17089e158ec4951f149e1935fd920af4ce483b8a57b693d875f88278be9811963 |
IEDL.DBID | RIE |
IngestDate | Thu Jun 29 18:38:16 EDT 2023 |
IsPeerReviewed | false |
IsScholarly | false |
Language | English |
LinkModel | DirectLink |
MergedId | FETCHMERGED-LOGICAL-c748-17089e158ec4951f149e1935fd920af4ce483b8a57b693d875f88278be9811963 |
PageCount | 4 |
ParticipantIDs | ieee_primary_4412148 |
PublicationCentury | 2000 |
PublicationDate | 2007-Oct. |
PublicationDateYYYYMMDD | 2007-10-01 |
PublicationDate_xml | – month: 10 year: 2007 text: 2007-Oct. |
PublicationDecade | 2000 |
PublicationTitle | 2007 International Conference on Electrical Machines and Systems (ICEMS) |
PublicationTitleAbbrev | ICEMS |
PublicationYear | 2007 |
Publisher | IEEE |
Publisher_xml | – name: IEEE |
Score | 1.4116268 |
Snippet | The dynamic voltage restorer (DVR) as a means of series compensation for mitigating the effect of voltage sags has been established as a preferred approach for... |
SourceID | ieee |
SourceType | Publisher |
StartPage | 98 |
SubjectTerms | Computer simulation Costs EMTDC Energy storage Fault current limiters Power quality PSCAD Switches Time factors Voltage |
Title | A novel improved combined Dynamic Voltage Restorer (DVR) using Fault Current Limiter (FCL) structure |
URI | https://ieeexplore.ieee.org/document/4412148 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV3PS8MwFA7bTp5UNvE3OXhwYLd2TdvkKHNFxYnolN1Gk7yIOFoZrQf_el_SOlE8eAsl0DYv7fe-l_e-R8iJVhByRGZPah15uCmMxyPBvDjjRnHEG6MtUZzexpeP7HoezVvkbF0LAwAu-QwGdujO8nWhKhsqGyJ0j9B9b5N2IkRdq9WkbAW-GF6NJ9OHAFlWXCsTNrN_tE1xqJFukunX_epkkddBVcqB-vglxfjfB9oive_6PHq3Rp5t0oK8S_Q5zYt3WNIXFycATXEzIe_FwUXddp4-FcsS_x_03rWTgRU9RVDqU5v7_kzTrFqWtNFronXhE85Ixzd9WqvMVivokVk6mY0vvaaHgqcShvww8bmAIOKgkAkFBvkQoMsWGS1GfmaYAsZDybMokbEINZIXgy53wiUINBR-nDukkxc57BKqkpFk1nyJYohoQqjYWHGYIOOMm9DfI127QIu3WiVj0azN_t-XD8iGi5K6tLhD0sHXgCOE91IeO7t-AkUwpJc |
link.rule.ids | 310,311,783,787,792,793,799,27937,55086 |
linkProvider | IEEE |
linkToHtml | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV3PT4MwFG7mPOhJzWb8bQ8eXCITRoH2aObIpmMxOs1uC7SvxriAWcCDf72PgjMaD94a0gToK3zve33ve4ScKQkuR2S2EqU8CzeFtrgnmOXHXEuOeKNVSRSjiT98ZDczb9YgF6taGAAwyWfQLYfmLF9lsihDZZcI3T1039fIOvrV3K-qteqkLccWl6P-IHpwkGf5lTZhPf9H4xSDG-EWib7uWKWLvHaLPOnKj19ijP99pG3S_q7Qo3cr7NkhDUhbRF3RNHuHBX0xkQJQFLcTMl8cXFeN5-lTtsjxD0LvTUMZWNJzhKUOLbPfn2kYF4uc1opNtCp9whlhf9yhlc5ssYQ2mYaDaX9o1V0ULBkwZIiBzQU4HgeJXMjRyIgAnTZPK9GzY80kMO4mPPaCxBeuQvqi0ekOeAICTYWf5y5pplkKe4TKoJew0oCBZIhpQkhfl_IwTswZ1669T1rlAs3fKp2Meb02B39fPiUbw2k0no9Hk9tDsmlipiZJ7og08ZXgGME-T06MjT8BEUin4g |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Abook&rft.genre=proceeding&rft.title=2007+International+Conference+on+Electrical+Machines+and+Systems+%28ICEMS%29&rft.atitle=A+novel+improved+combined+Dynamic+Voltage+Restorer+%28DVR%29+using+Fault+Current+Limiter+%28FCL%29+structure&rft.au=Hosseini%2C+S.H.&rft.au=Abapour%2C+M.&rft.au=Sabahi%2C+M.&rft.date=2007-10-01&rft.pub=IEEE&rft.spage=98&rft.epage=101&rft_id=info:doi/10.1109%2FICEMS12746.2007.4412148&rft.externalDocID=4412148 |