Detection of movement onset using EMG signals for upper-limb exoskeletons in reaching tasks
To assist people with disabilities, exoskeletons must be provided with human-robot interfaces and smart algorithms capable to identify the user's movement intentions. Surface electromyographic (sEMG) signals could be suitable for this purpose, but their applicability in shared control schemes f...
Saved in:
Published in | Journal of neuroengineering and rehabilitation Vol. 16; no. 1; pp. 45 - 16 |
---|---|
Main Authors | , , , , , , , |
Format | Journal Article |
Language | English |
Published |
England
BioMed Central Ltd
29.03.2019
BioMed Central BMC |
Subjects | |
Online Access | Get full text |
ISSN | 1743-0003 1743-0003 |
DOI | 10.1186/s12984-019-0512-1 |
Cover
Loading…
Abstract | To assist people with disabilities, exoskeletons must be provided with human-robot interfaces and smart algorithms capable to identify the user's movement intentions. Surface electromyographic (sEMG) signals could be suitable for this purpose, but their applicability in shared control schemes for real-time operation of assistive devices in daily-life activities is limited due to high inter-subject variability, which requires custom calibrations and training. Here, we developed a machine-learning-based algorithm for detecting the user's motion intention based on electromyographic signals, and discussed its applicability for controlling an upper-limb exoskeleton for people with severe arm disabilities.
Ten healthy participants, sitting in front of a screen while wearing the exoskeleton, were asked to perform several reaching movements toward three LEDs, presented in a random order. EMG signals from seven upper-limb muscles were recorded. Data were analyzed offline and used to develop an algorithm that identifies the onset of the movement across two different events: moving from a resting position toward the LED (Go-forward), and going back to resting position (Go-backward). A set of subject-independent time-domain EMG features was selected according to information theory and their probability distributions corresponding to rest and movement phases were modeled by means of a two-component Gaussian Mixture Model (GMM). The detection of movement onset by two types of detectors was tested: the first type based on features extracted from single muscles, whereas the second from multiple muscles. Their performances in terms of sensitivity, specificity and latency were assessed for the two events with a leave one-subject out test method.
The onset of movement was detected with a maximum sensitivity of 89.3% for Go-forward and 60.9% for Go-backward events. Best performances in terms of specificity were 96.2 and 94.3% respectively. For both events the algorithm was able to detect the onset before the actual movement, while computational load was compatible with real-time applications.
The detection performances and the low computational load make the proposed algorithm promising for the control of upper-limb exoskeletons in real-time applications. Fast initial calibration makes it also suitable for helping people with severe arm disabilities in performing assisted functional tasks. |
---|---|
AbstractList | To assist people with disabilities, exoskeletons must be provided with human-robot interfaces and smart algorithms capable to identify the user's movement intentions. Surface electromyographic (sEMG) signals could be suitable for this purpose, but their applicability in shared control schemes for real-time operation of assistive devices in daily-life activities is limited due to high inter-subject variability, which requires custom calibrations and training. Here, we developed a machine-learning-based algorithm for detecting the user's motion intention based on electromyographic signals, and discussed its applicability for controlling an upper-limb exoskeleton for people with severe arm disabilities.BACKGROUNDTo assist people with disabilities, exoskeletons must be provided with human-robot interfaces and smart algorithms capable to identify the user's movement intentions. Surface electromyographic (sEMG) signals could be suitable for this purpose, but their applicability in shared control schemes for real-time operation of assistive devices in daily-life activities is limited due to high inter-subject variability, which requires custom calibrations and training. Here, we developed a machine-learning-based algorithm for detecting the user's motion intention based on electromyographic signals, and discussed its applicability for controlling an upper-limb exoskeleton for people with severe arm disabilities.Ten healthy participants, sitting in front of a screen while wearing the exoskeleton, were asked to perform several reaching movements toward three LEDs, presented in a random order. EMG signals from seven upper-limb muscles were recorded. Data were analyzed offline and used to develop an algorithm that identifies the onset of the movement across two different events: moving from a resting position toward the LED (Go-forward), and going back to resting position (Go-backward). A set of subject-independent time-domain EMG features was selected according to information theory and their probability distributions corresponding to rest and movement phases were modeled by means of a two-component Gaussian Mixture Model (GMM). The detection of movement onset by two types of detectors was tested: the first type based on features extracted from single muscles, whereas the second from multiple muscles. Their performances in terms of sensitivity, specificity and latency were assessed for the two events with a leave one-subject out test method.METHODSTen healthy participants, sitting in front of a screen while wearing the exoskeleton, were asked to perform several reaching movements toward three LEDs, presented in a random order. EMG signals from seven upper-limb muscles were recorded. Data were analyzed offline and used to develop an algorithm that identifies the onset of the movement across two different events: moving from a resting position toward the LED (Go-forward), and going back to resting position (Go-backward). A set of subject-independent time-domain EMG features was selected according to information theory and their probability distributions corresponding to rest and movement phases were modeled by means of a two-component Gaussian Mixture Model (GMM). The detection of movement onset by two types of detectors was tested: the first type based on features extracted from single muscles, whereas the second from multiple muscles. Their performances in terms of sensitivity, specificity and latency were assessed for the two events with a leave one-subject out test method.The onset of movement was detected with a maximum sensitivity of 89.3% for Go-forward and 60.9% for Go-backward events. Best performances in terms of specificity were 96.2 and 94.3% respectively. For both events the algorithm was able to detect the onset before the actual movement, while computational load was compatible with real-time applications.RESULTSThe onset of movement was detected with a maximum sensitivity of 89.3% for Go-forward and 60.9% for Go-backward events. Best performances in terms of specificity were 96.2 and 94.3% respectively. For both events the algorithm was able to detect the onset before the actual movement, while computational load was compatible with real-time applications.The detection performances and the low computational load make the proposed algorithm promising for the control of upper-limb exoskeletons in real-time applications. Fast initial calibration makes it also suitable for helping people with severe arm disabilities in performing assisted functional tasks.CONCLUSIONSThe detection performances and the low computational load make the proposed algorithm promising for the control of upper-limb exoskeletons in real-time applications. Fast initial calibration makes it also suitable for helping people with severe arm disabilities in performing assisted functional tasks. Abstract Background To assist people with disabilities, exoskeletons must be provided with human-robot interfaces and smart algorithms capable to identify the user’s movement intentions. Surface electromyographic (sEMG) signals could be suitable for this purpose, but their applicability in shared control schemes for real-time operation of assistive devices in daily-life activities is limited due to high inter-subject variability, which requires custom calibrations and training. Here, we developed a machine-learning-based algorithm for detecting the user’s motion intention based on electromyographic signals, and discussed its applicability for controlling an upper-limb exoskeleton for people with severe arm disabilities. Methods Ten healthy participants, sitting in front of a screen while wearing the exoskeleton, were asked to perform several reaching movements toward three LEDs, presented in a random order. EMG signals from seven upper-limb muscles were recorded. Data were analyzed offline and used to develop an algorithm that identifies the onset of the movement across two different events: moving from a resting position toward the LED (Go-forward), and going back to resting position (Go-backward). A set of subject-independent time-domain EMG features was selected according to information theory and their probability distributions corresponding to rest and movement phases were modeled by means of a two-component Gaussian Mixture Model (GMM). The detection of movement onset by two types of detectors was tested: the first type based on features extracted from single muscles, whereas the second from multiple muscles. Their performances in terms of sensitivity, specificity and latency were assessed for the two events with a leave one-subject out test method. Results The onset of movement was detected with a maximum sensitivity of 89.3% for Go-forward and 60.9% for Go-backward events. Best performances in terms of specificity were 96.2 and 94.3% respectively. For both events the algorithm was able to detect the onset before the actual movement, while computational load was compatible with real-time applications. Conclusions The detection performances and the low computational load make the proposed algorithm promising for the control of upper-limb exoskeletons in real-time applications. Fast initial calibration makes it also suitable for helping people with severe arm disabilities in performing assisted functional tasks. To assist people with disabilities, exoskeletons must be provided with human-robot interfaces and smart algorithms capable to identify the user's movement intentions. Surface electromyographic (sEMG) signals could be suitable for this purpose, but their applicability in shared control schemes for real-time operation of assistive devices in daily-life activities is limited due to high inter-subject variability, which requires custom calibrations and training. Here, we developed a machine-learning-based algorithm for detecting the user's motion intention based on electromyographic signals, and discussed its applicability for controlling an upper-limb exoskeleton for people with severe arm disabilities. Ten healthy participants, sitting in front of a screen while wearing the exoskeleton, were asked to perform several reaching movements toward three LEDs, presented in a random order. EMG signals from seven upper-limb muscles were recorded. Data were analyzed offline and used to develop an algorithm that identifies the onset of the movement across two different events: moving from a resting position toward the LED (Go-forward), and going back to resting position (Go-backward). A set of subject-independent time-domain EMG features was selected according to information theory and their probability distributions corresponding to rest and movement phases were modeled by means of a two-component Gaussian Mixture Model (GMM). The detection of movement onset by two types of detectors was tested: the first type based on features extracted from single muscles, whereas the second from multiple muscles. Their performances in terms of sensitivity, specificity and latency were assessed for the two events with a leave one-subject out test method. The onset of movement was detected with a maximum sensitivity of 89.3% for Go-forward and 60.9% for Go-backward events. Best performances in terms of specificity were 96.2 and 94.3% respectively. For both events the algorithm was able to detect the onset before the actual movement, while computational load was compatible with real-time applications. The detection performances and the low computational load make the proposed algorithm promising for the control of upper-limb exoskeletons in real-time applications. Fast initial calibration makes it also suitable for helping people with severe arm disabilities in performing assisted functional tasks. Background To assist people with disabilities, exoskeletons must be provided with human-robot interfaces and smart algorithms capable to identify the user's movement intentions. Surface electromyographic (sEMG) signals could be suitable for this purpose, but their applicability in shared control schemes for real-time operation of assistive devices in daily-life activities is limited due to high inter-subject variability, which requires custom calibrations and training. Here, we developed a machine-learning-based algorithm for detecting the user's motion intention based on electromyographic signals, and discussed its applicability for controlling an upper-limb exoskeleton for people with severe arm disabilities. Methods Ten healthy participants, sitting in front of a screen while wearing the exoskeleton, were asked to perform several reaching movements toward three LEDs, presented in a random order. EMG signals from seven upper-limb muscles were recorded. Data were analyzed offline and used to develop an algorithm that identifies the onset of the movement across two different events: moving from a resting position toward the LED (Go-forward), and going back to resting position (Go-backward). A set of subject-independent time-domain EMG features was selected according to information theory and their probability distributions corresponding to rest and movement phases were modeled by means of a two-component Gaussian Mixture Model (GMM). The detection of movement onset by two types of detectors was tested: the first type based on features extracted from single muscles, whereas the second from multiple muscles. Their performances in terms of sensitivity, specificity and latency were assessed for the two events with a leave one-subject out test method. Results The onset of movement was detected with a maximum sensitivity of 89.3% for Go-forward and 60.9% for Go-backward events. Best performances in terms of specificity were 96.2 and 94.3% respectively. For both events the algorithm was able to detect the onset before the actual movement, while computational load was compatible with real-time applications. Conclusions The detection performances and the low computational load make the proposed algorithm promising for the control of upper-limb exoskeletons in real-time applications. Fast initial calibration makes it also suitable for helping people with severe arm disabilities in performing assisted functional tasks. Keywords: Upper-limb exoskeleton, Electromyography, Human-robot interface, Onset detection To assist people with disabilities, exoskeletons must be provided with human-robot interfaces and smart algorithms capable to identify the user's movement intentions. Surface electromyographic (sEMG) signals could be suitable for this purpose, but their applicability in shared control schemes for real-time operation of assistive devices in daily-life activities is limited due to high inter-subject variability, which requires custom calibrations and training. Here, we developed a machine-learning-based algorithm for detecting the user's motion intention based on electromyographic signals, and discussed its applicability for controlling an upper-limb exoskeleton for people with severe arm disabilities. Ten healthy participants, sitting in front of a screen while wearing the exoskeleton, were asked to perform several reaching movements toward three LEDs, presented in a random order. EMG signals from seven upper-limb muscles were recorded. Data were analyzed offline and used to develop an algorithm that identifies the onset of the movement across two different events: moving from a resting position toward the LED (Go-forward), and going back to resting position (Go-backward). A set of subject-independent time-domain EMG features was selected according to information theory and their probability distributions corresponding to rest and movement phases were modeled by means of a two-component Gaussian Mixture Model (GMM). The detection of movement onset by two types of detectors was tested: the first type based on features extracted from single muscles, whereas the second from multiple muscles. Their performances in terms of sensitivity, specificity and latency were assessed for the two events with a leave one-subject out test method. The onset of movement was detected with a maximum sensitivity of 89.3% for Go-forward and 60.9% for Go-backward events. Best performances in terms of specificity were 96.2 and 94.3% respectively. For both events the algorithm was able to detect the onset before the actual movement, while computational load was compatible with real-time applications. The detection performances and the low computational load make the proposed algorithm promising for the control of upper-limb exoskeletons in real-time applications. Fast initial calibration makes it also suitable for helping people with severe arm disabilities in performing assisted functional tasks. Background To assist people with disabilities, exoskeletons must be provided with human-robot interfaces and smart algorithms capable to identify the user’s movement intentions. Surface electromyographic (sEMG) signals could be suitable for this purpose, but their applicability in shared control schemes for real-time operation of assistive devices in daily-life activities is limited due to high inter-subject variability, which requires custom calibrations and training. Here, we developed a machine-learning-based algorithm for detecting the user’s motion intention based on electromyographic signals, and discussed its applicability for controlling an upper-limb exoskeleton for people with severe arm disabilities. Methods Ten healthy participants, sitting in front of a screen while wearing the exoskeleton, were asked to perform several reaching movements toward three LEDs, presented in a random order. EMG signals from seven upper-limb muscles were recorded. Data were analyzed offline and used to develop an algorithm that identifies the onset of the movement across two different events: moving from a resting position toward the LED (Go-forward), and going back to resting position (Go-backward). A set of subject-independent time-domain EMG features was selected according to information theory and their probability distributions corresponding to rest and movement phases were modeled by means of a two-component Gaussian Mixture Model (GMM). The detection of movement onset by two types of detectors was tested: the first type based on features extracted from single muscles, whereas the second from multiple muscles. Their performances in terms of sensitivity, specificity and latency were assessed for the two events with a leave one-subject out test method. Results The onset of movement was detected with a maximum sensitivity of 89.3% for Go-forward and 60.9% for Go-backward events. Best performances in terms of specificity were 96.2 and 94.3% respectively. For both events the algorithm was able to detect the onset before the actual movement, while computational load was compatible with real-time applications. Conclusions The detection performances and the low computational load make the proposed algorithm promising for the control of upper-limb exoskeletons in real-time applications. Fast initial calibration makes it also suitable for helping people with severe arm disabilities in performing assisted functional tasks. |
ArticleNumber | 45 |
Audience | Academic |
Author | Trigili, Emilio Panarese, Alessandro Vitiello, Nicola Accogli, Alessandro Carpaneto, Jacopo Micera, Silvestro Grazi, Lorenzo Crea, Simona |
Author_xml | – sequence: 1 givenname: Emilio orcidid: 0000-0002-3725-5694 surname: Trigili fullname: Trigili, Emilio – sequence: 2 givenname: Lorenzo surname: Grazi fullname: Grazi, Lorenzo – sequence: 3 givenname: Simona surname: Crea fullname: Crea, Simona – sequence: 4 givenname: Alessandro surname: Accogli fullname: Accogli, Alessandro – sequence: 5 givenname: Jacopo surname: Carpaneto fullname: Carpaneto, Jacopo – sequence: 6 givenname: Silvestro surname: Micera fullname: Micera, Silvestro – sequence: 7 givenname: Nicola surname: Vitiello fullname: Vitiello, Nicola – sequence: 8 givenname: Alessandro surname: Panarese fullname: Panarese, Alessandro |
BackLink | https://www.ncbi.nlm.nih.gov/pubmed/30922326$$D View this record in MEDLINE/PubMed |
BookMark | eNp1ks1u1DAUhSNURH_gAdggS2zYpPg6jhNvkKq2lEpFbGDFwnLsm6mniT3YSQVvj8NMUacCZRHr5pzPPs45Lg588FgUr4GeArTifQImW15SkCWtgZXwrDiChlclpbQ6eLQ-LI5TWucFpzV_URxWVDJWMXFUfL_ACc3kgiehJ2O4xxH9RIJPOJE5Ob8il5-vSHIrr4dE-hDJvNlgLAc3dgR_hnSHA05ZT5wnEbW5XTyTTnfpZfG8zyZ8tXufFN8-Xn49_1TefLm6Pj-7KY1o5FQyK7rWCC51A5WsOo60QmHz2TuLFWst1KyzFFBo2rQcO2kYtS1ijXku6-qkuN5ybdBrtYlu1PGXCtqpP4MQV0rHyZkBVSW15SB5o_uGd5zLRlhrLNVScGCaZdaHLWszdyNaky8j6mEPuv_Fu1u1CvdKcE5ByAx4twPE8GPGNKnRJYPDoD2GOSnGaE5RNwKy9O0T6TrMcbnnrALg0GyBO9VK5wDO9yHvaxaoOqtbyL-UsuXcp_9Q5cfi6EyuTe_yfM_w5nHQvwkfqpEFzVZgYkgpYq-Mm_TSlEx2gwKqlhKqbQlVLqFaSqiWXPDE-QD_v-c32YDcoA |
CitedBy_id | crossref_primary_10_1109_LSENS_2021_3100607 crossref_primary_10_1021_acssensors_4c01445 crossref_primary_10_1016_j_cmpb_2020_105721 crossref_primary_10_1109_ACCESS_2023_3332116 crossref_primary_10_3390_machines9030056 crossref_primary_10_3390_app12042069 crossref_primary_10_3390_bioengineering12020144 crossref_primary_10_1080_17483107_2020_1806937 crossref_primary_10_3390_s25051606 crossref_primary_10_1142_S0218348X21502546 crossref_primary_10_1007_s11571_021_09776_w crossref_primary_10_3390_electronics11091335 crossref_primary_10_1109_TBME_2023_3346358 crossref_primary_10_1109_TMRB_2024_3377278 crossref_primary_10_1186_s12984_024_01529_0 crossref_primary_10_1109_TRO_2021_3137748 crossref_primary_10_1186_s12984_024_01316_x crossref_primary_10_1088_1741_2552_ab9db9 crossref_primary_10_1016_j_compbiomed_2024_109169 crossref_primary_10_1109_LRA_2023_3303701 crossref_primary_10_1109_TIM_2022_3225015 crossref_primary_10_1007_s43154_020_00015_4 crossref_primary_10_1371_journal_pone_0255597 crossref_primary_10_1007_s11517_024_03019_w crossref_primary_10_1017_wtc_2024_16 crossref_primary_10_1109_TNSRE_2022_3228018 crossref_primary_10_1016_j_bspc_2023_104936 crossref_primary_10_1088_2634_4386_ac4a83 crossref_primary_10_3390_s22218134 crossref_primary_10_4015_S1016237220500064 crossref_primary_10_3390_app10062101 crossref_primary_10_3390_s24134202 crossref_primary_10_1152_jn_00024_2023 crossref_primary_10_1109_ACCESS_2023_3307417 crossref_primary_10_1109_TNSRE_2023_3236834 crossref_primary_10_3389_fnins_2021_660141 crossref_primary_10_1093_gigascience_giaa098 crossref_primary_10_3389_fnbot_2021_693110 crossref_primary_10_1016_j_bspc_2020_102345 crossref_primary_10_1109_TMRB_2023_3320260 crossref_primary_10_3390_app11020883 crossref_primary_10_1016_j_bspc_2023_104774 crossref_primary_10_1016_j_bspc_2021_102475 crossref_primary_10_3390_bioengineering11020119 crossref_primary_10_3390_app11157130 crossref_primary_10_1016_j_cobme_2021_100313 crossref_primary_10_1038_s41598_023_30716_7 crossref_primary_10_1016_j_mechatronics_2022_102808 crossref_primary_10_1186_s12883_023_03369_2 crossref_primary_10_3390_electronics12010196 crossref_primary_10_4218_etrij_2021_0417 crossref_primary_10_3389_fnbot_2023_1264802 crossref_primary_10_1016_j_bspc_2021_102707 crossref_primary_10_1016_j_mattod_2024_12_002 crossref_primary_10_3390_e26100829 crossref_primary_10_1142_S0218348X21502728 crossref_primary_10_3390_s22030884 crossref_primary_10_1088_1741_2552_abef3a crossref_primary_10_1109_TVCG_2023_3308787 crossref_primary_10_1088_1748_3190_ad912c crossref_primary_10_1109_ACCESS_2020_3015761 crossref_primary_10_1109_TNSRE_2022_3196361 crossref_primary_10_1007_s10479_024_06451_1 crossref_primary_10_3389_frobt_2024_1308958 crossref_primary_10_1186_s12984_023_01268_8 crossref_primary_10_3389_fbioe_2020_00362 crossref_primary_10_3390_s21165411 crossref_primary_10_1109_TIM_2024_3384565 crossref_primary_10_3389_frobt_2023_1123374 crossref_primary_10_1109_ACCESS_2024_3508029 crossref_primary_10_1515_bmt_2020_0343 crossref_primary_10_3389_fnins_2025_1532099 crossref_primary_10_1109_ACCESS_2022_3141162 crossref_primary_10_1109_JSEN_2023_3259150 crossref_primary_10_1109_TASE_2020_3033664 |
Cites_doi | 10.1371/journal.pone.0085060 10.1007/978-3-319-46532-6_30 10.1109/IEMBS.2009.5333984 10.1109/TMECH.2006.871087 10.1615/CritRevBiomedEng.v30.i456.80 10.1109/79.543975 10.1109/IEMBS.2003.1279672 10.1186/1743-0003-11-3 10.1007/BF02348122 10.1016/j.dcan.2015.02.004 10.1186/1475-925X-9-72 10.1109/TBME.2005.856295 10.1109/TBME.2012.2198821 10.3389/fnbot.2018.00005 10.1088/0954-898X/14/1/303 10.1016/S0074-7742(09)86001-7 10.1016/j.bspc.2007.07.009 10.1126/scirobotics.aag3296 10.1109/TMECH.2011.2160354 10.1017/S0263574718001340 10.1016/S1050-6411(00)00027-4 10.1109/10.204774 10.1103/PhysRevE.92.063302 10.1371/journal.pone.0127990 10.1186/1471-2202-10-81 10.1038/s41598-018-29091-5 10.1109/TMECH.2016.2558646 10.1016/j.plrev.2015.11.006 10.1108/01439910210425522 10.1109/TBME.2003.813539 10.1109/MEMB.2010.936548 10.3389/fnins.2016.00295 10.3390/s130912431 10.1016/S0304-3940(00)01471-3 10.1109/TNSRE.2014.2305111 10.1109/TITB.2010.2040832 |
ContentType | Journal Article |
Copyright | COPYRIGHT 2019 BioMed Central Ltd. 2019. This work is licensed under http://creativecommons.org/licenses/by/4.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License. The Author(s). 2019 |
Copyright_xml | – notice: COPYRIGHT 2019 BioMed Central Ltd. – notice: 2019. This work is licensed under http://creativecommons.org/licenses/by/4.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License. – notice: The Author(s). 2019 |
DBID | AAYXX CITATION CGR CUY CVF ECM EIF NPM 3V. 7QO 7RV 7TB 7TK 7TS 7X7 7XB 88C 88E 8FD 8FE 8FG 8FH 8FI 8FJ 8FK ABJCF ABUWG AFKRA AZQEC BBNVY BENPR BGLVJ BHPHI CCPQU DWQXO FR3 FYUFA GHDGH GNUQQ HCIFZ K9. KB0 L6V LK8 M0S M0T M1P M7P M7S NAPCQ P64 PHGZM PHGZT PIMPY PJZUB PKEHL PPXIY PQEST PQGLB PQQKQ PQUKI PRINS PTHSS 7X8 5PM DOA |
DOI | 10.1186/s12984-019-0512-1 |
DatabaseName | CrossRef Medline MEDLINE MEDLINE (Ovid) MEDLINE MEDLINE PubMed ProQuest Central (Corporate) Biotechnology Research Abstracts Nursing & Allied Health Database Mechanical & Transportation Engineering Abstracts Neurosciences Abstracts Physical Education Index Health & Medical Collection ProQuest Central (purchase pre-March 2016) Healthcare Administration Database (Alumni) Medical Database (Alumni Edition) Technology Research Database ProQuest SciTech Collection ProQuest Technology Collection ProQuest Natural Science Collection Hospital Premium Collection Hospital Premium Collection (Alumni Edition) ProQuest Central (Alumni) (purchase pre-March 2016) Materials Science & Engineering Collection ProQuest Central (Alumni) ProQuest Central UK/Ireland ProQuest Central Essentials Biological Science Collection ProQuest Central Technology Collection Natural Science Collection ProQuest One ProQuest Central Engineering Research Database Proquest Health Research Premium Collection Health Research Premium Collection (Alumni) ProQuest Central Student SciTech Premium Collection ProQuest Health & Medical Complete (Alumni) Nursing & Allied Health Database (Alumni Edition) ProQuest Engineering Collection Biological Sciences ProQuest Health & Medical Collection Healthcare Administration Database Medical Database Biological Science Database Engineering Database Nursing & Allied Health Premium Biotechnology and BioEngineering Abstracts ProQuest Central Premium ProQuest One Academic (New) Publicly Available Content Database ProQuest Health & Medical Research Collection ProQuest One Academic Middle East (New) ProQuest One Health & Nursing ProQuest One Academic Eastern Edition (DO NOT USE) ProQuest One Applied & Life Sciences ProQuest One Academic ProQuest One Academic UKI Edition ProQuest Central China Engineering Collection MEDLINE - Academic PubMed Central (Full Participant titles) DOAJ Directory of Open Access Journals |
DatabaseTitle | CrossRef MEDLINE Medline Complete MEDLINE with Full Text PubMed MEDLINE (Ovid) Publicly Available Content Database ProQuest Central Student ProQuest Central Essentials SciTech Premium Collection ProQuest Central China ProQuest One Applied & Life Sciences Health Research Premium Collection Natural Science Collection Health & Medical Research Collection Biological Science Collection ProQuest Central (New) ProQuest Medical Library (Alumni) Engineering Collection Engineering Database ProQuest Biological Science Collection ProQuest One Academic Eastern Edition ProQuest Hospital Collection ProQuest Technology Collection Health Research Premium Collection (Alumni) Biological Science Database Neurosciences Abstracts ProQuest Hospital Collection (Alumni) Biotechnology and BioEngineering Abstracts Nursing & Allied Health Premium ProQuest Health & Medical Complete ProQuest One Academic UKI Edition ProQuest Health Management (Alumni Edition) ProQuest Nursing & Allied Health Source (Alumni) Engineering Research Database ProQuest One Academic ProQuest One Academic (New) Technology Collection Technology Research Database ProQuest One Academic Middle East (New) Mechanical & Transportation Engineering Abstracts ProQuest Health & Medical Complete (Alumni) ProQuest Central (Alumni Edition) ProQuest One Community College ProQuest One Health & Nursing ProQuest Natural Science Collection Physical Education Index ProQuest Central ProQuest Health & Medical Research Collection ProQuest Engineering Collection Biotechnology Research Abstracts Health and Medicine Complete (Alumni Edition) ProQuest Central Korea ProQuest Health Management ProQuest Nursing & Allied Health Source ProQuest SciTech Collection ProQuest Medical Library Materials Science & Engineering Collection ProQuest Central (Alumni) MEDLINE - Academic |
DatabaseTitleList | MEDLINE - Academic MEDLINE Publicly Available Content Database |
Database_xml | – sequence: 1 dbid: DOA name: DOAJ Directory of Open Access Journals url: https://www.doaj.org/ sourceTypes: Open Website – sequence: 2 dbid: NPM name: PubMed url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed sourceTypes: Index Database – sequence: 3 dbid: EIF name: MEDLINE url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search sourceTypes: Index Database – sequence: 4 dbid: 8FG name: ProQuest Technology Collection url: https://search.proquest.com/technologycollection1 sourceTypes: Aggregation Database |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Medicine Engineering Occupational Therapy & Rehabilitation Physical Therapy |
EISSN | 1743-0003 |
EndPage | 16 |
ExternalDocumentID | oai_doaj_org_article_39ad41947af74b44976ddcd0a96412a2 PMC6440169 A581340022 30922326 10_1186_s12984_019_0512_1 |
Genre | Research Support, Non-U.S. Gov't Journal Article |
GrantInformation_xml | – fundername: H2020 LEIT Information and Communication Technologies grantid: 645322 - AIDE Project – fundername: Regione Toscana grantid: Bando FAS Salute 2014 (RONDA Project) – fundername: ; grantid: 645322 - AIDE Project – fundername: ; grantid: Bando FAS Salute 2014 (RONDA Project) |
GroupedDBID | --- 0R~ 29L 2QV 2WC 53G 5GY 5VS 7RV 7X7 88E 8FE 8FG 8FH 8FI 8FJ AAFWJ AAJSJ AASML AAWTL AAYXX ABDBF ABJCF ABUWG ACGFO ACGFS ACIWK ACPRK ACUHS ADBBV ADRAZ ADUKV AENEX AFKRA AFPKN AFRAH AHBYD AHMBA AHYZX ALIPV ALMA_UNASSIGNED_HOLDINGS AMKLP AMTXH AOIJS AQUVI BAPOH BAWUL BBNVY BCNDV BENPR BFQNJ BGLVJ BHPHI BMC BPHCQ BVXVI C6C CCPQU CITATION CS3 DIK DU5 E3Z EBD EBLON EBS EJD ESX F5P FYUFA GROUPED_DOAJ GX1 HCIFZ HMCUK HYE I-F IAO IHR INH INR IPY ITC KQ8 L6V LK8 M0T M1P M48 M7P M7S ML0 M~E NAPCQ O5R O5S OK1 OVT P2P PGMZT PHGZM PHGZT PIMPY PQQKQ PROAC PSQYO PTHSS RBZ RNS ROL RPM RSV SBL SOJ TR2 TUS UKHRP WOQ WOW XSB ~8M -A0 3V. ACRMQ ADINQ C24 CGR CUY CVF ECM EIF NPM PMFND 7QO 7TB 7TK 7TS 7XB 8FD 8FK AZQEC DWQXO FR3 GNUQQ K9. P64 PJZUB PKEHL PPXIY PQEST PQGLB PQUKI PRINS 7X8 5PM PUEGO |
ID | FETCH-LOGICAL-c679t-2d6b8c649a71393b4e03e6d743bde328d152bd01e6a0784eb9c20d8ee5e2bd953 |
IEDL.DBID | M48 |
ISSN | 1743-0003 |
IngestDate | Wed Aug 27 01:08:54 EDT 2025 Thu Aug 21 14:09:20 EDT 2025 Fri Jul 11 07:37:14 EDT 2025 Fri Jul 25 19:11:23 EDT 2025 Tue Jun 17 21:07:30 EDT 2025 Tue Jun 10 20:20:03 EDT 2025 Thu Jan 02 22:58:52 EST 2025 Thu Apr 24 23:07:04 EDT 2025 Tue Jul 01 02:19:57 EDT 2025 |
IsDoiOpenAccess | true |
IsOpenAccess | true |
IsPeerReviewed | true |
IsScholarly | true |
Issue | 1 |
Keywords | Human-robot interface Electromyography Onset detection Upper-limb exoskeleton |
Language | English |
License | Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
LinkModel | DirectLink |
MergedId | FETCHMERGED-LOGICAL-c679t-2d6b8c649a71393b4e03e6d743bde328d152bd01e6a0784eb9c20d8ee5e2bd953 |
Notes | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 14 content type line 23 |
ORCID | 0000-0002-3725-5694 |
OpenAccessLink | https://www.proquest.com/docview/2211417169?pq-origsite=%requestingapplication% |
PMID | 30922326 |
PQID | 2211417169 |
PQPubID | 55356 |
PageCount | 16 |
ParticipantIDs | doaj_primary_oai_doaj_org_article_39ad41947af74b44976ddcd0a96412a2 pubmedcentral_primary_oai_pubmedcentral_nih_gov_6440169 proquest_miscellaneous_2200785761 proquest_journals_2211417169 gale_infotracmisc_A581340022 gale_infotracacademiconefile_A581340022 pubmed_primary_30922326 crossref_citationtrail_10_1186_s12984_019_0512_1 crossref_primary_10_1186_s12984_019_0512_1 |
ProviderPackageCode | CITATION AAYXX |
PublicationCentury | 2000 |
PublicationDate | 2019-03-29 |
PublicationDateYYYYMMDD | 2019-03-29 |
PublicationDate_xml | – month: 03 year: 2019 text: 2019-03-29 day: 29 |
PublicationDecade | 2010 |
PublicationPlace | England |
PublicationPlace_xml | – name: England – name: London |
PublicationTitle | Journal of neuroengineering and rehabilitation |
PublicationTitleAlternate | J Neuroeng Rehabil |
PublicationYear | 2019 |
Publisher | BioMed Central Ltd BioMed Central BMC |
Publisher_xml | – name: BioMed Central Ltd – name: BioMed Central – name: BMC |
References | 512_CR16 T Lenzi (512_CR12) 2012; 59 M Zecca (512_CR19) 2002; 30 512_CR33 A Phinyomark (512_CR26) 2009; 1 S Waldert (512_CR5) 2016; 10 Y Huang (512_CR17) 2005; 52 RH Chowdhury (512_CR31) 2013; 13 A Úbeda (512_CR7) 2011; 16 B Hudgins (512_CR34) 1993; 40 HJ Hermens (512_CR25) 2000; 10 G Pola (512_CR28) 2003 P Maciejasz (512_CR2) 2014; 11 DP Ferris (512_CR14) 2013 J Pratt (512_CR23) 2002; 29 FD Farfan (512_CR36) 2010; 9 JL Pons (512_CR4) 2010; 29 512_CR27 S Crea (512_CR21) 2016 512_CR22 A Accogli (512_CR39) 2017; 16 M Asghari Oskoei (512_CR18) 2007; 2 M Hamedi (512_CR30) 2014 S Crea (512_CR10) 2018; 8 SR Soekadar (512_CR8) 2016; 1 J Liu (512_CR20) 2015; 10 PK Artemiadis (512_CR32) 2010; 14 M Pazzaglia (512_CR3) 2016; 16 R Singh (512_CR11) 2012; 3 C Magri (512_CR29) 2009; 10 D Farina (512_CR13) 2014; 22 512_CR9 AB Zoss (512_CR1) 2006; 11 FC Schasfoort (512_CR37) 2002; 40 C Lauretti (512_CR38) 2018; 12 EJ Rechy-Ramirez (512_CR15) 2015; 1 F Giovacchini (512_CR24) 2015 G Pfurtscheller (512_CR6) 2000; 292 K Englehart (512_CR35) 2003; 50 N Vitiello (512_CR40) 2016; 21 |
References_xml | – ident: 512_CR9 doi: 10.1371/journal.pone.0085060 – volume: 16 start-page: 181 issue: i year: 2017 ident: 512_CR39 publication-title: Biosyst Biorobotics doi: 10.1007/978-3-319-46532-6_30 – start-page: 2119 volume-title: Robotic lower limb exoskeletons using proportional myoelectric control year: 2013 ident: 512_CR14 doi: 10.1109/IEMBS.2009.5333984 – volume: 11 start-page: 128 year: 2006 ident: 512_CR1 publication-title: IEEE/ASME Trans Mechatronics. doi: 10.1109/TMECH.2006.871087 – volume: 30 start-page: 459 year: 2002 ident: 512_CR19 publication-title: Crit Rev Biomed Eng doi: 10.1615/CritRevBiomedEng.v30.i456.80 – ident: 512_CR27 doi: 10.1109/79.543975 – ident: 512_CR33 doi: 10.1109/IEMBS.2003.1279672 – volume: 11 start-page: 3 year: 2014 ident: 512_CR2 publication-title: J Neuroeng Rehabil doi: 10.1186/1743-0003-11-3 – volume: 40 start-page: 173 year: 2002 ident: 512_CR37 publication-title: Med Biol Eng Comput doi: 10.1007/BF02348122 – volume: 1 start-page: 85 year: 2015 ident: 512_CR15 publication-title: Digit Commun Networks doi: 10.1016/j.dcan.2015.02.004 – volume: 9 start-page: 72 year: 2010 ident: 512_CR36 publication-title: Biomed Eng Online doi: 10.1186/1475-925X-9-72 – volume: 52 start-page: 1801 year: 2005 ident: 512_CR17 publication-title: IEEE Trans Biomed Eng doi: 10.1109/TBME.2005.856295 – volume: 59 start-page: 2180 issue: 8 year: 2012 ident: 512_CR12 publication-title: IEEE Trans Biomed Eng doi: 10.1109/TBME.2012.2198821 – volume: 12 start-page: 1 year: 2018 ident: 512_CR38 publication-title: Front Neurorobot doi: 10.3389/fnbot.2018.00005 – start-page: 35 volume-title: An exact method to quantify the information transmitted by different mechanisms of correlational coding year: 2003 ident: 512_CR28 doi: 10.1088/0954-898X/14/1/303 – ident: 512_CR16 doi: 10.1016/S0074-7742(09)86001-7 – volume: 2 start-page: 275 year: 2007 ident: 512_CR18 publication-title: Biomed Signal Process Control doi: 10.1016/j.bspc.2007.07.009 – volume: 1 start-page: eaag3296 year: 2016 ident: 512_CR8 publication-title: Sci Robot doi: 10.1126/scirobotics.aag3296 – volume: 16 start-page: 870 year: 2011 ident: 512_CR7 publication-title: IEEE/ASME Trans Mechatronics doi: 10.1109/TMECH.2011.2160354 – ident: 512_CR22 doi: 10.1017/S0263574718001340 – volume: 10 start-page: 361 year: 2000 ident: 512_CR25 publication-title: J Electromyogr Kinesiol Off J Int Soc Electrophysiol Kinesiol doi: 10.1016/S1050-6411(00)00027-4 – volume: 40 start-page: 82 year: 1993 ident: 512_CR34 publication-title: IEEE Trans Biomed Eng doi: 10.1109/10.204774 – volume-title: Torsional Trasmission Element with Elastic Response year: 2015 ident: 512_CR24 doi: 10.1103/PhysRevE.92.063302 – volume: 10 year: 2015 ident: 512_CR20 publication-title: PLoS One doi: 10.1371/journal.pone.0127990 – start-page: 1248 volume-title: Proceedings of the IEEE RAS and EMBS International Conference on Biomedical Robotics and Biomechatronics year: 2016 ident: 512_CR21 – volume: 10 start-page: 81 year: 2009 ident: 512_CR29 publication-title: BMC Neurosci doi: 10.1186/1471-2202-10-81 – volume: 8 year: 2018 ident: 512_CR10 publication-title: Sci Rep doi: 10.1038/s41598-018-29091-5 – volume: 21 start-page: 1880 issue: 4 year: 2016 ident: 512_CR40 publication-title: IEEE/ASME Trans Mechatronics. doi: 10.1109/TMECH.2016.2558646 – volume: 16 start-page: 163 year: 2016 ident: 512_CR3 publication-title: Phys Life Rev doi: 10.1016/j.plrev.2015.11.006 – volume: 1 start-page: 71 issue: 1 year: 2009 ident: 512_CR26 publication-title: J Comput – volume: 29 start-page: 234 year: 2002 ident: 512_CR23 publication-title: Ind Robot An Int J doi: 10.1108/01439910210425522 – volume: 3 start-page: 1 year: 2012 ident: 512_CR11 publication-title: Int J Sci Eng Res – volume: 50 start-page: 848 issue: 7 year: 2003 ident: 512_CR35 publication-title: IEEE Trans Biomed Eng doi: 10.1109/TBME.2003.813539 – volume: 29 start-page: 57 year: 2010 ident: 512_CR4 publication-title: IEEE Eng Med Biol Mag doi: 10.1109/MEMB.2010.936548 – volume: 10 start-page: 1 year: 2016 ident: 512_CR5 publication-title: Front Neurosci doi: 10.3389/fnins.2016.00295 – volume: 13 start-page: 12431 issue: 9 year: 2013 ident: 512_CR31 publication-title: Sensors (Switzerland) doi: 10.3390/s130912431 – start-page: 285 volume-title: Lecture Notes in Electrical Engineering year: 2014 ident: 512_CR30 – volume: 292 start-page: 211 year: 2000 ident: 512_CR6 publication-title: Neurosci Lett doi: 10.1016/S0304-3940(00)01471-3 – volume: 22 start-page: 797 year: 2014 ident: 512_CR13 publication-title: IEEE Trans Neural Syst Rehabil Eng doi: 10.1109/TNSRE.2014.2305111 – volume: 14 start-page: 582 year: 2010 ident: 512_CR32 publication-title: IEEE Trans Inf Technol Biomed doi: 10.1109/TITB.2010.2040832 |
SSID | ssj0034054 |
Score | 2.527194 |
Snippet | To assist people with disabilities, exoskeletons must be provided with human-robot interfaces and smart algorithms capable to identify the user's movement... Background To assist people with disabilities, exoskeletons must be provided with human-robot interfaces and smart algorithms capable to identify the user's... Background To assist people with disabilities, exoskeletons must be provided with human-robot interfaces and smart algorithms capable to identify the user’s... Abstract Background To assist people with disabilities, exoskeletons must be provided with human-robot interfaces and smart algorithms capable to identify the... |
SourceID | doaj pubmedcentral proquest gale pubmed crossref |
SourceType | Open Website Open Access Repository Aggregation Database Index Database Enrichment Source |
StartPage | 45 |
SubjectTerms | Adult Algorithms Analysis Arm Calibration Computation Computer applications Data processing Detection equipment Diagnosis Disabilities Disabled persons Elbow Electrodes Electroencephalography Electromyography Electromyography - methods Exoskeleton Exoskeleton Device Exoskeletons Feasibility studies Feature extraction Female Human-computer interaction Human-robot interface Humans Information theory Interfaces Latency Learning algorithms LEDs Machine Learning Male Man-machine interfaces Motion detection Motion perception Movement Movement - physiology Muscles Onset detection People with disabilities Principal components analysis Probabilistic models Probability distributions Real time operation Risk factors Robots Sensitivity Sensitivity analysis Sensors Signal processing Test procedures Upper Extremity - physiology Upper-limb exoskeleton |
SummonAdditionalLinks | – databaseName: DOAJ Directory of Open Access Journals dbid: DOA link: http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwrV1bi9QwFA6yD6IPuo63uqtE8AJC2DZN0-Rx1V0XYURkFxZ8CLlVh91th2kH_PmepJlhiqAvPg00p0yT8-Wc79DTLwi9apzOhdeCVIZaAhmqIEbWDWmqRkYFu1Eyf_6Fn12wz5fV5c5RX6EnbJQHHhfuqJTaMai0a93UzDAG6dM563ItOSuojtEXct6mmBpjcAk0hKV3mIXgRz1kNRG6LSQBEFJSTLJQFOv_MyTv5KRpv-ROAjrdR_cSc8TH4xM_QLd8O0N3d_QEZ-j2PL0pn6HXu_LB-HzUDsBv8LeJMvcM3f-aHLWxeYi-f_RDbNBqcdfgmy4qig84tF0POPTJ_8An8084dH4AdjGwXrxeLv2KXC9uDPa_uv4Kchlwyh4vWrxK7Zp40P1V_whdnJ6cfzgj6QwGYnktB0IdN8JyJjVUs7I0zOel5w54h3G-pMJB_jcuLzzXQDaYN9LS3AnvKw_XZVU-Rntt1_qnCLPKCQ1xmTsLP9Ib44EsScptCX_haIbyjU-UTcsQzsm4VrFQEVyNblTgRhXcqIoMvdveshzVOf5m_D44emsYhLXjBYCbSnBT_4Jbht4GmKiw_eHhrE5fMcAUg5CWOq5EAegDZpShw4klbFs7Hd4ATaWw0SsK5TiLAkYZerkdDneGVrjWd-tgE2gdlIkwoScjLrdTKnMJdI_yDNUTxE7mPB1pFz-jqDjw4iDM8-x_LNIBukPjXgvHBB6ivWG19s-Buw3mRdymvwELvUBc priority: 102 providerName: Directory of Open Access Journals – databaseName: Health & Medical Collection dbid: 7X7 link: http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwfV3di9QwEA96guiDH6unq6dE8AOEcG2aps2TnHrnIayI3MGBD6H56LncXbtuu-Cf70yaXbcI91RopjTZmcz8ppn9DSGva1clpa9KlhtuGUSolBlV1KzOaxUY7AbK_Nk3eXwqvp7lZ_GDWxfLKtc-MThq11r8Rr7PIVMRgdvlw-I3w65ReLoaW2jcJLeQugxLuoqzTcKVARgR8SQzLeV-B7GtxJoLxcAUOUtHsShQ9v_vmLci07hqcisMHT0g9yJ-pAeDwh-SG76ZkLtbrIITcnsWz8sn5M02iTA9GRgE6Fv6Y8TPPSH3v0d1rWUekZ-ffR_KtBra1vSqDbziPcXi655itfw5PZx9oVj_ARZMAfvS1WLhl-xyfmWo_9N2FxDRAFl2dN7QZSzapH3VXXSPyenR4cmnYxY7MTArC9Uz7qQprRSqgpxWZUb4JPPSAfowzme8dIACjEtSLyuAHMIbZXniSu9zD_dVnu2SnaZt_FNCRe7KCryzdBYuyhvjATIpLm0Gr3B8SpK1TrSNPwN2y7jUIV0ppR7UqEGNGtWo0yl5v3lkMXB0XCf8ERW9EUR67XCjXZ7ruFt1pionUiWKqi6EEQIwm3PWJZWSIuUVTPIdmolGJwCTs1X8LwMsEem09EFepmB9gI-mZG8kCZvXjofXhqaj8-j0P1OfklebYXwSC-Ia365QBsEdJIuwoCeDXW6WlCUKQB-XU1KMLHa05vFIM_8VqMUBHSM9z7Prp_Wc3OFhF2EbwD2y0y9X_gVgs968DBvwLxyIOBE priority: 102 providerName: ProQuest |
Title | Detection of movement onset using EMG signals for upper-limb exoskeletons in reaching tasks |
URI | https://www.ncbi.nlm.nih.gov/pubmed/30922326 https://www.proquest.com/docview/2211417169 https://www.proquest.com/docview/2200785761 https://pubmed.ncbi.nlm.nih.gov/PMC6440169 https://doaj.org/article/39ad41947af74b44976ddcd0a96412a2 |
Volume | 16 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV3ra9swEBddC2P9sEf2ytYFDfaAgTc_ZFn6MEa6JS2BlNI1EOgHIVlyG5raWexA99_vJDshZmXsSwyWHFu6O9_vrNPvEHqXaekzI5kXqzD1wEMFnuJJ5mVxxh2DXU2ZPz6hxxMymsbTHbQub9VMYHlnaGfrSU2W88-3v35_A4P_6gye0S8l-Cxmcym4ByoWehAM7YFjSqydjslmUSECbELq_ZGR3UwdNYucd_5Fy005Nv-_39lbTqudULnloYaP0cMGWuJ-rQtP0I7JO2h_i3Cwg-6Pm6X0Dnq_zS-Mz2tyAfwBn7Wouzvo0WkjyXWfp-jih6lcBleOiwzfFI5yvMI2L7vCNpH-Eg_GR9imhsAkY4DFeLVYmKU3n90obG6L8hqcHYDOEs9yvGzyOXEly-vyGZoMB-ffj72mSIOX0oRXXqipYiklXEK4yyNFjB8ZqmGOlTZRyDQABKX9wFAJaIQYxdPQ18yY2MB5HkfP0W5e5OYlwiTWTMKLm-oUDtwoZQBN8ZCmEdxCh13kr2Ui0mYabCGNuXCRDKOiFqMAMQorRhF00afNJYuavuNfnQ-toDcdLfO2O1EsL0VjyCLiUpOAk0RmCVGEAJzTOtW-5JQEoYSH_GjVRFiNhYdLZbPNAYZombZEP2YBaCJApy46aPUEu07bzWtFE2uzECHE68QxHHXR202zvdLmyuWmWNk-FvdBHAkDelHr5WZIkc8BD4a0i5KWxrbG3G7JZ1eOdRyAs2XuefUf932NHoTOlGyZwAO0Wy1X5g1gt0r10L1kmsAvGx710F6_P_o5guPh4OT0rOe-h_Sczf4BqFRE0g |
linkProvider | Scholars Portal |
linkToHtml | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwtV1bb9MwFLamIXF54FJugQFGYiBNipY4jhM_IDTYRsfWCaFOqsSDiWNnVNuS0qQC_hS_kXNyKY2Q9ranSLGj2D2379Qn3yHkVWYSL7ZJ7IaapS5EKN_VMsrcLMxkzWDXUOaPjsXwhH-ahJM18qf7FgbLKjufWDtqU6T4H_k2g0yF19wu72Y_XOwahaerXQuNRi0O7e-fkLKVbw92Qb6bjO3vjT8M3bargJuKSFYuM0LHqeAygfxMBppbL7DCQCTVxgYsNhDRtPF8KxIIn9xqmTLPxNaGFu5L7BIBLv8abMtDi4omywQvAPDD25NTPxbbJcTSGGs8pAuqz1y_F_vqFgH_B4KVSNiv0lwJe_t3ye0Wr9KdRsHukTWbD8itFRbDAbk-as_nB2RzlbSYjhvGAvqafunxgQ_Inc-tenRz7pOvu7aqy8JyWmT0oqh5zCuKxd4Vxer8U7o3-kix3gQshgLWpovZzM7d8-mFpvZXUZ5BBAUkW9JpTudtkSitkvKsfEBOrkRGD8l6XuT2MaE8NHEC0UCYFC7Sam0Bokkm0gBeYZhDvE4mKm1_BuzOca7q9CgWqhGjAjEqFKPyHbK1fGTWcIJcNvk9Cno5Eem86xvF_FS13kEFMjHclzxKsohrzgEjGpMaL5GC-yyBRb5BNVHodGBxadJ-OwFbRPoutRPGPmgf4DGHbPRmgrNI-8OdoqnWWZXqn2k55OVyGJ_EArzcFgucg2ASklPY0KNGL5dbCjwJIJMJh0Q9je3tuT-ST7_XVOaAxpEO6Mnly3pBbgzHoyN1dHB8-JTcZLVFYQvCDbJezRf2GeDCSj-vjZGSb1dt_X8BxIZ1Ig |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Detection+of+movement+onset+using+EMG+signals+for+upper-limb+exoskeletons+in+reaching+tasks&rft.jtitle=Journal+of+neuroengineering+and+rehabilitation&rft.au=Trigili%2C+Emilio&rft.au=Grazi%2C+Lorenzo&rft.au=Crea%2C+Simona&rft.au=Accogli%2C+Alessandro&rft.date=2019-03-29&rft.issn=1743-0003&rft.eissn=1743-0003&rft.volume=16&rft.issue=1&rft.spage=45&rft_id=info:doi/10.1186%2Fs12984-019-0512-1&rft.externalDBID=NO_FULL_TEXT |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1743-0003&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1743-0003&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1743-0003&client=summon |