Less Frequent Sequence Mismatches in Variants of Concern (VOCs) of SARS-CoV-2 in the Real-Time RT-PCR Assays Developed by the National Institute of Infectious Diseases, Japan

Various variants of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) began emerging worldwide from the end of 2020 to the beginning of 2021. The variants GRY/VOC202012/01 (B1.1.7), GH/N501Y.V2 (B1.351), and GR/N501Y.V3 (P1) are characterized by N to Y amino acid substitution at position...

Full description

Saved in:
Bibliographic Details
Published inJapanese Journal of Infectious Diseases Vol. 75; no. 1; pp. 96 - 101
Main Authors Shirato, Kazuya, Matsuyama, Shutoku, Takeda, Makoto
Format Journal Article
LanguageEnglish
Published Japan National Institute of Infectious Diseases, Japanese Journal of Infectious Diseases Editorial Committee 31.01.2022
Japan Science and Technology Agency
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Various variants of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) began emerging worldwide from the end of 2020 to the beginning of 2021. The variants GRY/VOC202012/01 (B1.1.7), GH/N501Y.V2 (B1.351), and GR/N501Y.V3 (P1) are characterized by N to Y amino acid substitution at position 501 in the S protein. The variant containing L to R substitution at position 452 in the S protein G/L452R.V3 (B1.617) was endemic to India. The heightened concern regarding these variants is related to their increased viral infectivity. Information about nucleotide mismatch(es) on the primer/probe sequence is important for maintaining good performance of real-time PCR assays. In this study, real-time RT-PCR assays developed by the National Institute of Infectious Diseases, Japan (NIID-N2 and NIID-S2 assays), were reviewed to analyze nucleotide mismatches of variants in primer/probe sequences. The frequency of mismatched sequences in three variants (GRY/VOC202012/01, GH/N501Y.V2, and GR/N501Y.V3) was lower than that in all SARS-CoV-2 sequences. The mismatch, that G to C substitution at nucleotide 8 in reverse primer of S2 set, elevated to about 16.3% in G/L452R.V3, however the substitution did not affect the analytical sensitivity of assay. Therefore, the study indicates that the NIID-N2 and NIID-S2 sets detect VOCs of SARS-CoV-2 with reliable efficiency.