Efforts to improve the diagnostic accuracy of endoscopic ultrasound-guided fine-needle aspiration for pancreatic tumors
Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) is widely used to obtain a definitive diagnosis of pancreatic tumors. Good results have been reported for its diagnostic accuracy, with high sensitivity and specificity of around 90%; however, technological developments and adaptations to...
Saved in:
Published in | Endoscopic Ultrasound Vol. 5; no. 4; pp. 225 - 232 |
---|---|
Main Authors | , , , , , , , , , , , |
Format | Journal Article |
Language | English |
Published |
China
Wolters Kluwer - Medknow Publications
01.07.2016
Medknow Publications and Media Pvt. Ltd Medknow Publications & Media Pvt Ltd |
Subjects | |
Online Access | Get full text |
Cover
Loading…
Abstract | Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) is widely used to obtain a definitive diagnosis of pancreatic tumors. Good results have been reported for its diagnostic accuracy, with high sensitivity and specificity of around 90%; however, technological developments and adaptations to improve it still further are currently underway. The endosonographic technique can be improved when several tips and tricks useful to overcome challenges of EUS-FNA are known. This review provides various techniques and equipment for improvement in the diagnostic accuracy in EUS-FNA. |
---|---|
AbstractList | Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) is widely used to obtain a definitive diagnosis of pancreatic tumors. Good results have been reported for its diagnostic accuracy, with high sensitivity and specificity of around 90%; however, technological developments and adaptations to improve it still further are currently underway. The endosonographic technique can be improved when several tips and tricks useful to overcome challenges of EUS-FNA are known. This review provides various techniques and equipment for improvement in the diagnostic accuracy in EUS-FNA. |
Audience | Academic |
Author | Yamamoto, Shogo Shibukawa, Goro Sato, Ai Arakawa, Noriyuki Yamabe, Akane Fujisawa, Mariko Yoshida, Yoshitsugu Igarashi, Ryo Irisawa, Atsushi Maki, Takumi Ikeda, Tsunehiko Bhutani, Manoop |
AuthorAffiliation | Aizu Medical Center, Fukushima Medical University, Aizuwakamatsu, Japan 1 MD Anderson Cancer Center, University of Texas, Houston, TX, USA |
AuthorAffiliation_xml | – name: 1 MD Anderson Cancer Center, University of Texas, Houston, TX, USA – name: Aizu Medical Center, Fukushima Medical University, Aizuwakamatsu, Japan |
Author_xml | – sequence: 1 givenname: Akane surname: Yamabe fullname: Yamabe, Akane organization: Aizu Medical Center, Fukushima Medical University, Aizuwakamatsu – sequence: 2 givenname: Atsushi surname: Irisawa fullname: Irisawa, Atsushi organization: Aizu Medical Center, Fukushima Medical University, Aizuwakamatsu – sequence: 3 givenname: Manoop surname: Bhutani fullname: Bhutani, Manoop organization: MD Anderson Cancer Center, University of Texas, Houston, TX – sequence: 4 givenname: Goro surname: Shibukawa fullname: Shibukawa, Goro organization: Aizu Medical Center, Fukushima Medical University, Aizuwakamatsu – sequence: 5 givenname: Mariko surname: Fujisawa fullname: Fujisawa, Mariko organization: Aizu Medical Center, Fukushima Medical University, Aizuwakamatsu – sequence: 6 givenname: Ai surname: Sato fullname: Sato, Ai organization: Aizu Medical Center, Fukushima Medical University, Aizuwakamatsu – sequence: 7 givenname: Yoshitsugu surname: Yoshida fullname: Yoshida, Yoshitsugu organization: Aizu Medical Center, Fukushima Medical University, Aizuwakamatsu – sequence: 8 givenname: Noriyuki surname: Arakawa fullname: Arakawa, Noriyuki organization: Aizu Medical Center, Fukushima Medical University, Aizuwakamatsu – sequence: 9 givenname: Tsunehiko surname: Ikeda fullname: Ikeda, Tsunehiko organization: Aizu Medical Center, Fukushima Medical University, Aizuwakamatsu – sequence: 10 givenname: Ryo surname: Igarashi fullname: Igarashi, Ryo organization: Aizu Medical Center, Fukushima Medical University, Aizuwakamatsu – sequence: 11 givenname: Takumi surname: Maki fullname: Maki, Takumi organization: Aizu Medical Center, Fukushima Medical University, Aizuwakamatsu – sequence: 12 givenname: Shogo surname: Yamamoto fullname: Yamamoto, Shogo organization: Aizu Medical Center, Fukushima Medical University, Aizuwakamatsu |
BackLink | https://www.ncbi.nlm.nih.gov/pubmed/27503153$$D View this record in MEDLINE/PubMed |
BookMark | eNptks1r2zAchs3oWLus952GYDB2caYvy_ZlUEr3AYVdetlJKPLPiagseZLc0P--Mk5KAsMgG-l5X2TpeV9cOO-gKD4SvOYEs2-UYVa2mNZr0tSNoG-KK0qpKGvS4ov8fVy-LK5jNBvMec2qhjXviktaV5iRil0V-7u-9yFFlDwywxj8E6C0A9QZtXU-JqOR0noKSj8j3yNwnY_aj3l6simo6CfXldvJdNCh3jgoHUBnAak4mqCS8Q7lfjQqpwOouS5Ngw_xQ_G2VzbC9eG9Kh5-3D3c_irv__z8fXtzX2rBaSoJqTcaWtYSXm0wE4KrXvWd4II2ouaK5c0BIYrpuhZd1eIcq4WiAmDTUs1Wxfeldpw2A3QaXN60lWMwgwrP0isjz1ec2cmtf5K8bVqOaS74eigI_t8EMcnBRA3WKgd-ipI0BFeVaDDJ6OcF3SoL0rje50Y94_KGC8wqwfK4Ktb_ofLTwWB0vuHe5PmzwJeTwA6UTbvo7TSfbTwH8QLq4GMM0L_-JsFyNkbOSshZCbkYkyOfTo_nNXD0IwN_F2DvbYIQH-20hyAz--j8_qy4PCmWlFbyYJZMXh7MktkseTSLvQDOH91I |
CitedBy_id | crossref_primary_10_5946_ce_2018_160 crossref_primary_10_1002_pbc_27519 crossref_primary_10_3390_diagnostics11122272 crossref_primary_10_1007_s10620_019_5468_2 crossref_primary_10_1016_j_pan_2022_04_005 crossref_primary_10_18528_ijgii220019 crossref_primary_10_12998_wjcc_v9_i14_3308 crossref_primary_10_1155_2019_5810653 crossref_primary_10_1080_00365521_2020_1825792 crossref_primary_10_1016_j_gie_2019_11_018 crossref_primary_10_3748_wjg_v23_i47_8345 crossref_primary_10_3892_ol_2018_8652 crossref_primary_10_17235_reed_2019_5914_2018 crossref_primary_10_1002_acm2_13266 crossref_primary_10_1055_a_1713_3404 crossref_primary_10_3748_wjg_v23_i32_5962 crossref_primary_10_1155_2022_4486241 crossref_primary_10_1111_jgh_15264 crossref_primary_10_1016_j_gie_2018_06_024 |
Cites_doi | 10.1055/s-0035-1553496 10.1016/j.gie.2014.04.012 10.1016/j.gie.2015.03.1807 |
ContentType | Journal Article |
Copyright | COPYRIGHT 2016 Medknow Publications and Media Pvt. Ltd. Copyright: © 2016 Spring Media Publishing Co. Ltd 2016 |
Copyright_xml | – notice: COPYRIGHT 2016 Medknow Publications and Media Pvt. Ltd. – notice: Copyright: © 2016 Spring Media Publishing Co. Ltd 2016 |
DBID | NPM AAYXX CITATION 7X8 5PM |
DOI | 10.4103/2303-9027.187862 |
DatabaseName | PubMed CrossRef MEDLINE - Academic PubMed Central (Full Participant titles) |
DatabaseTitle | PubMed CrossRef MEDLINE - Academic |
DatabaseTitleList | MEDLINE - Academic PubMed |
Database_xml | – sequence: 1 dbid: NPM name: PubMed url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed sourceTypes: Index Database |
DeliveryMethod | fulltext_linktorsrc |
EISSN | 2226-7190 |
EndPage | 232 |
ExternalDocumentID | A460356360 10_4103_2303_9027_187862 27503153 10.4103/2303-9027.187862_225_Efforts to improve the diagnost |
Genre | Journal Article Review |
GroupedDBID | ACGFS ADBBV ADRAZ AENEX ALMA_UNASSIGNED_HOLDINGS AOIJS BAWUL DIK H13 HYE IAO IEA IHR IHW ITC KQ8 M48 M~E N95 OVD RMW RPM W3E NPM OK1 AAYXX CITATION 7X8 0R~ 5PM ADPDF OVEED PGMZT TEORI |
ID | FETCH-LOGICAL-c642t-117bce939145b03664afafd64628674a3acce11a3c776d590c6476a26eeb92c3 |
IEDL.DBID | RPM |
ISSN | 2303-9027 |
IngestDate | Tue Sep 17 21:20:36 EDT 2024 Fri Apr 12 14:07:23 EDT 2024 Thu Feb 22 23:53:17 EST 2024 Wed Oct 25 09:53:21 EDT 2023 Tue Aug 20 21:57:27 EDT 2024 Fri Aug 23 02:05:47 EDT 2024 Sat Nov 02 12:19:05 EDT 2024 Thu May 25 13:39:27 EDT 2023 |
IsDoiOpenAccess | true |
IsOpenAccess | true |
IsPeerReviewed | true |
IsScholarly | true |
Issue | 4 |
Keywords | endoscopic ultrasound-guided fine-needle aspiration Diagnostic accuracy pancreatic tumors |
Language | English |
License | http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms. |
LinkModel | DirectLink |
MergedId | FETCHMERGED-LOGICAL-c642t-117bce939145b03664afafd64628674a3acce11a3c776d590c6476a26eeb92c3 |
Notes | ObjectType-Article-2 SourceType-Scholarly Journals-1 ObjectType-Feature-3 content type line 23 ObjectType-Review-1 |
OpenAccessLink | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4989402/ |
PMID | 27503153 |
PQID | 1810556801 |
PQPubID | 23479 |
PageCount | 8 |
ParticipantIDs | pubmedcentral_primary_oai_pubmedcentral_nih_gov_4989402 proquest_miscellaneous_1810556801 gale_infotracmisc_A460356360 gale_infotracacademiconefile_A460356360 gale_healthsolutions_A460356360 crossref_primary_10_4103_2303_9027_187862 pubmed_primary_27503153 wolterskluwer_medknow_10_4103_2303-9027_187862_225_Efforts_to_improve_the_diagnost |
PublicationCentury | 2000 |
PublicationDate | 2016-07-01 |
PublicationDateYYYYMMDD | 2016-07-01 |
PublicationDate_xml | – month: 07 year: 2016 text: 2016-07-01 day: 01 |
PublicationDecade | 2010 |
PublicationPlace | China |
PublicationPlace_xml | – name: China – name: India |
PublicationTitle | Endoscopic Ultrasound |
PublicationTitleAlternate | Endosc Ultrasound |
PublicationYear | 2016 |
Publisher | Wolters Kluwer - Medknow Publications Medknow Publications and Media Pvt. Ltd Medknow Publications & Media Pvt Ltd |
Publisher_xml | – name: Wolters Kluwer - Medknow Publications – name: Medknow Publications and Media Pvt. Ltd – name: Medknow Publications & Media Pvt Ltd |
References | Stelow (key-10.4103/2303-9027.187862-70) 2005 Alper (key-10.4103/2303-9027.187862-10) 2016 Song (key-10.4103/2303-9027.187862-19) 2010 Mohammad (key-10.4103/2303-9027.187862-47) 2014 Rösch (key-10.4103/2303-9027.187862-1) 1991 Hébert-Magee (key-10.4103/2303-9027.187862-60) 2013 Yasuda (key-10.4103/2303-9027.187862-61) 2012 Fabbri (key-10.4103/2303-9027.187862-21) 2011 Gerke (key-10.4103/2303-9027.187862-13) 2009 Madhoun (key-10.4103/2303-9027.187862-25) 2011 Carrara (key-10.4103/2303-9027.187862-26) 2016 Mavrogenis (key-10.4103/2303-9027.187862-23) 2015 Iwashita (key-10.4103/2303-9027.187862-64) 2015 key-10.4103/2303-9027.187862-44 Affolter (key-10.4103/2303-9027.187862-11) 2013 Witt (key-10.4103/2303-9027.187862-6) 2013 Yamabe (key-10.4103/2303-9027.187862-32) 2016 Lee (key-10.4103/2303-9027.187862-18) 2009 Williams (key-10.4103/2303-9027.187862-4) 1999 Vilmann (key-10.4103/2303-9027.187862-2) 1992 Wiersema (key-10.4103/2303-9027.187862-3) 1997 Turner (key-10.4103/2303-9027.187862-35) 2010 Erickson (key-10.4103/2303-9027.187862-33) 2000 Berzosa (key-10.4103/2303-9027.187862-24) 2015 Erickson (key-10.4103/2303-9027.187862-42) 2000 Bang (key-10.4103/2303-9027.187862-7) 2016 key-10.4103/2303-9027.187862-38 Fabbri (key-10.4103/2303-9027.187862-17) 2009 key-10.4103/2303-9027.187862-31 Mukai (key-10.4103/2303-9027.187862-28) 2016 Mehmood (key-10.4103/2303-9027.187862-40) 2015 Yoshinaga (key-10.4103/2303-9027.187862-5) 2011 Attam (key-10.4103/2303-9027.187862-29) 2015 Gimeno-García (key-10.4103/2303-9027.187862-22) 2014 Yusuf (key-10.4103/2303-9027.187862-14) 2009 Lee (key-10.4103/2303-9027.187862-46) 2013 Chen (key-10.4103/2303-9027.187862-56) 2012 Villa (key-10.4103/2303-9027.187862-30) 2016 Hikichi (key-10.4103/2303-9027.187862-62) 2009 Nakai (key-10.4103/2303-9027.187862-48) 2014 Hocke (key-10.4103/2303-9027.187862-52) 2006 Sugimoto (key-10.4103/2303-9027.187862-54) 2015 Irisawa (key-10.4103/2303-9027.187862-65) 2009 Hou (key-10.4103/2303-9027.187862-55) 2015 Kitano (key-10.4103/2303-9027.187862-50) 2015 Ganc (key-10.4103/2303-9027.187862-39) 2015 Schmidt (key-10.4103/2303-9027.187862-59) 2013 Noda (key-10.4103/2303-9027.187862-69) 2010 Skov (key-10.4103/2303-9027.187862-72) 2007 key-10.4103/2303-9027.187862-8 Krishnan (key-10.4103/2303-9027.187862-57) 2013 Ramesh (key-10.4103/2303-9027.187862-12) 2015 Eltoum (key-10.4103/2303-9027.187862-73) 2007 Bang (key-10.4103/2303-9027.187862-27) 2013 Suzuki (key-10.4103/2303-9027.187862-41) 2012 LeBlanc (key-10.4103/2303-9027.187862-34) 2004 Siddiqui (key-10.4103/2303-9027.187862-16) 2009 Haba (key-10.4103/2303-9027.187862-58) 2013 Hayashi (key-10.4103/2303-9027.187862-63) 2013 Jenssen (key-10.4103/2303-9027.187862-71) 2008 Matsumoto (key-10.4103/2303-9027.187862-66) 2015 Camellini (key-10.4103/2303-9027.187862-20) 2011 Kin (key-10.4103/2303-9027.187862-49) 2015 Itoi (key-10.4103/2303-9027.187862-36) 2011 Polkowski (key-10.4103/2303-9027.187862-68) 2012 Sakamoto (key-10.4103/2303-9027.187862-15) 2009 Ecka (key-10.4103/2303-9027.187862-37) 2013 Wani (key-10.4103/2303-9027.187862-43) 2012 Kulesza (key-10.4103/2303-9027.187862-67) 2007 Vanbiervliet (key-10.4103/2303-9027.187862-9) 2014 Puri (key-10.4103/2303-9027.187862-45) 2009 key-10.4103/2303-9027.187862-53 Kitano (key-10.4103/2303-9027.187862-51) 2012 |
References_xml | – start-page: 29 volume-title: Role of endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) for diagnosis of solid pancreatic masses year: 2011 ident: key-10.4103/2303-9027.187862-5 publication-title: Dig Endosc contributor: fullname: Yoshinaga – start-page: 278 volume-title: Onsite cytopathology evaluation and ancillary studies beneficial in EUS-FNA of pancreatic, mediastinal, intra-abdominal, and submucosal lesions year: 2015 ident: key-10.4103/2303-9027.187862-40 publication-title: Diagn Cytopathol contributor: fullname: Mehmood – start-page: 647 volume-title: Endoscopic ultrasound-guided fine needle aspiration with 22- and 25-gauge needles in solid pancreatic masses: A prospective comparative study with randomisation of needle sequence year: 2011 ident: key-10.4103/2303-9027.187862-21 publication-title: Dig Liver Dis contributor: fullname: Fabbri – start-page: 467 volume-title: Randomized controlled trial comparing stylet-free endoscopic ultrasound-guided fine-needle aspiration with 22-G and 25-G needles year: 2014 ident: key-10.4103/2303-9027.187862-22 publication-title: Dig Endosc contributor: fullname: Gimeno-García – start-page: e0121236 volume-title: Contrast-enhanced harmonic endoscopic ultrasound-guided fine-needle aspiration in the diagnosis of solid pancreatic lesions: A retrospective study year: 2015 ident: key-10.4103/2303-9027.187862-55 publication-title: PLoS One contributor: fullname: Hou – start-page: 745 volume-title: A prospective, comparative trial to optimize sampling techniques in EUS-guided FNA of solid pancreatic masses year: 2013 ident: key-10.4103/2303-9027.187862-46 publication-title: Gastrointest Endosc contributor: fullname: Lee – start-page: 128 volume-title: Randomized trial comparing the flexible 19G and 25G needles for endoscopic ultrasound-guided fine needle aspiration of solid pancreatic mass lesions year: 2015 ident: key-10.4103/2303-9027.187862-12 publication-title: Pancreas contributor: fullname: Ramesh – start-page: 445 volume-title: Randomized trial comparing fanning with standard technique for endoscopic ultrasound-guided fine-needle aspiration of solid pancreatic mass lesions year: 2013 ident: key-10.4103/2303-9027.187862-27 publication-title: Endoscopy contributor: fullname: Bang – start-page: 397 volume-title: Endoscopic ultrasound-guided fine needle aspiration biopsy for diagnosis of lymphoproliferative disorders: Feasibility of immunohistological, flow cytometric, and cytogenetic assessments year: 2012 ident: key-10.4103/2303-9027.187862-61 publication-title: Am J Gastroenterol contributor: fullname: Yasuda – start-page: 303 volume-title: Characterization of small solid tumors in the pancreas: The value of contrast-enhanced harmonic endoscopic ultrasonography year: 2012 ident: key-10.4103/2303-9027.187862-51 publication-title: Am J Gastroenterol contributor: fullname: Kitano – start-page: 2274 volume-title: Blinded prospective comparison of the performance of 22-gauge and 25-gauge needles in endoscopic ultrasound-guided fine needle aspiration of the pancreas and peri-pancreatic lesions year: 2009 ident: key-10.4103/2303-9027.187862-18 publication-title: Dig Dis Sci contributor: fullname: Lee – start-page: 709 volume-title: A randomized clinical trial comparing 22G and 25G needles in endoscopic ultrasound-guided fine-needle aspiration of solid lesions year: 2011 ident: key-10.4103/2303-9027.187862-20 publication-title: Endoscopy contributor: fullname: Camellini – start-page: 1063 volume-title: Core needle versus standard needle for endoscopic ultrasound-guided biopsy of solid pancreatic masses: A randomized crossover study year: 2014 ident: key-10.4103/2303-9027.187862-9 publication-title: Endoscopy contributor: fullname: Vanbiervliet – start-page: 1069 volume-title: A comparative needle study: EUS-FNA procedures using the HD ProCore(™) and EchoTip(®) 22-gauge needle types year: 2013 ident: key-10.4103/2303-9027.187862-6 publication-title: Diagn Cytopathol contributor: fullname: Witt – start-page: 503 volume-title: Rapid on-site cytopathological examination (ROSE) performed by endosonagraphers and its improvement in the diagnosis of pancreatic solid lesions year: 2015 ident: key-10.4103/2303-9027.187862-39 publication-title: Acta Cir Bras contributor: fullname: Ganc – start-page: 452 volume-title: Prospective evaluation of the optimal number of 25-gauge needle passes for endoscopic ultrasound-guided fine-needle aspiration biopsy of solid pancreatic lesions in the absence of an onsite cytopathologist year: 2012 ident: key-10.4103/2303-9027.187862-41 publication-title: Dig Endosc contributor: fullname: Suzuki – start-page: 720 volume-title: Endoscopic ultrasound guided fine needle aspiration biopsy: A large single centre experience year: 1999 ident: key-10.4103/2303-9027.187862-4 publication-title: Gut contributor: fullname: Williams – start-page: 2248 volume-title: Impact of endoscopic ultrasound on the management and outcome of pancreatic carcinoma year: 2000 ident: key-10.4103/2303-9027.187862-42 publication-title: Am J Gastroenterol contributor: fullname: Erickson – start-page: 1248 volume-title: Endoscopic ultrasound-guided fine-needle aspiration: Sampling, pitfalls, and quality management year: 2007 ident: key-10.4103/2303-9027.187862-67 publication-title: Clin Gastroenterol Hepatol contributor: fullname: Kulesza – start-page: 1578 volume-title: Slow pull versus suction in endoscopic ultrasound-guided fine-needle aspiration of pancreatic solid masses year: 2014 ident: key-10.4103/2303-9027.187862-48 publication-title: Dig Dis Sci contributor: fullname: Nakai – start-page: S60 volume-title: Comparative study of EUS-guided 25 gauge needle versus EUS-guided 22 gauge needle for FNA in patients with solid pancreatic masses: Preliminary results year: 2009 ident: key-10.4103/2303-9027.187862-17 publication-title: Dig Liver Dis contributor: fullname: Fabbri – start-page: 590 volume-title: Endoscopic ultrasound-guided biopsy: Diagnostic yield, pitfalls, quality management part 1: Optimizing specimen collection and diagnostic efficiency year: 2008 ident: key-10.4103/2303-9027.187862-71 publication-title: Z Gastroenterol contributor: fullname: Jenssen – start-page: 1210 volume-title: Multicenter, prospective, crossover trial comparing the door-knocking method with the conventional method for EUS-FNA of solid pancreatic masses (with videos) year: 2016 ident: key-10.4103/2303-9027.187862-28 publication-title: Gastrointest Endosc contributor: fullname: Mukai – start-page: 900 volume-title: Diagnostic ability of EUS-FNA for pancreatic solid lesions with conventional 22-gauge needle using the slow pull technique: A prospective study year: 2015 ident: key-10.4103/2303-9027.187862-49 publication-title: Scand J Gastroenterol contributor: fullname: Kin – start-page: 445 volume-title: Retrospective analysis of the utility of endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) in pancreatic masses, using a 22-gauge or 25-gauge needle system: A multicenter experience year: 2009 ident: key-10.4103/2303-9027.187862-14 publication-title: Endoscopy contributor: fullname: Yusuf – start-page: E63 volume-title: 25-gauge histology needle versus 22-gauge cytology needle in endoscopic ultrasonography-guided sampling of pancreatic lesions and lymphadenopathy year: 2015 ident: key-10.4103/2303-9027.187862-23 publication-title: Endosc Int Open contributor: fullname: Mavrogenis – start-page: 328 volume-title: Diagnostic yield of malignancy during EUS-guided FNA of solid lesions with and without a stylet: A prospective, single blind, randomized, controlled trial year: 2012 ident: key-10.4103/2303-9027.187862-43 publication-title: Gastrointest Endosc contributor: fullname: Wani – start-page: 1026 volume-title: Needle size has only a limited effect on outcomes in EUS-guided fine needle aspiration: A systematic review and meta-analysis year: 2013 ident: key-10.4103/2303-9027.187862-11 publication-title: Dig Dis Sci contributor: fullname: Affolter – start-page: 1 volume-title: Endoscopic ultrasound-guided tissue sampling: How can we improve the results? year: 2016 ident: key-10.4103/2303-9027.187862-10 publication-title: Turk J Gastroenterol contributor: fullname: Alper – start-page: E662 volume-title: Development of a device for detecting target specimens from EUS-guided FNA samples year: 2015 ident: key-10.4103/2303-9027.187862-66 publication-title: Endosc Int Open contributor: fullname: Matsumoto – start-page: AB154 volume-title: The diagnostic accuracy of 22- and 25-gauge needles in EUS-FNA of solid pancreatic lesions: A meta-analysis year: 2011 ident: key-10.4103/2303-9027.187862-25 publication-title: Gastrointest Endosc contributor: fullname: Madhoun – start-page: E56 volume-title: An experimental study to assess the best maneuver when using a reverse side-bevel histology needle for EUS-guided fine-needle biopsy year: 2016 ident: key-10.4103/2303-9027.187862-32 publication-title: Endosc Int Open contributor: fullname: Yamabe – start-page: 656 volume-title: Rapid on-site evaluation by endosonographer during endoscopic ultrasound-guided fine needle aspiration for pancreatic solid masses year: 2013 ident: key-10.4103/2303-9027.187862-63 publication-title: J Gastroenterol Hepatol contributor: fullname: Hayashi – start-page: 34 volume-title: Histological diagnosis by EUS-guided fine-needle aspiration biopsy in pancreatic solid masses without on-site cytopathologist: A single-center experience year: 2011 ident: key-10.4103/2303-9027.187862-36 publication-title: Dig Endosc contributor: fullname: Itoi – start-page: 143 volume-title: Cumulative sum procedure in evaluation of EUS-guided FNA cytology: The learning curve and diagnostic performance beyond sensitivity and specificity year: 2007 ident: key-10.4103/2303-9027.187862-73 publication-title: Cytopathology contributor: fullname: Eltoum – start-page: 49 volume-title: A prospective randomized study comparing 25-G and 22-G needles of a new platform for endoscopic ultrasound-guided fine needle aspiration of solid masses year: 2016 ident: key-10.4103/2303-9027.187862-26 publication-title: Dig Liver Dis contributor: fullname: Carrara – start-page: 1098 volume-title: EUS-guided FNA: Better samples with smaller needles? year: 2009 ident: key-10.4103/2303-9027.187862-13 publication-title: Gastrointest Endosc contributor: fullname: Gerke – start-page: 3280 volume-title: Rapid on-site evaluation reduces needle passes in endoscopic ultrasound-guided fine-needle aspiration for solid pancreatic lesions: A risk-benefit analysis year: 2013 ident: key-10.4103/2303-9027.187862-59 publication-title: Dig Dis Sci contributor: fullname: Schmidt – start-page: 184 volume-title: Factors predicting the number of EUS-guided fine-needle passes for diagnosis of pancreatic malignancies year: 2000 ident: key-10.4103/2303-9027.187862-33 publication-title: Gastrointest Endosc contributor: fullname: Erickson – ident: key-10.4103/2303-9027.187862-53 doi: 10.1055/s-0035-1553496 – start-page: 339 volume-title: A meta-analysis comparing ProCore and standard fine-needle aspiration needles for endoscopic ultrasound-guided tissue acquisition year: 2016 ident: key-10.4103/2303-9027.187862-7 publication-title: Endoscopy contributor: fullname: Bang – start-page: 538 volume-title: Conventional versus contrast-enhanced harmonic endoscopic ultrasonography-guided fine-needle aspiration for diagnosis of solid pancreatic lesions: A prospective randomized trial year: 2015 ident: key-10.4103/2303-9027.187862-54 publication-title: Pancreatology contributor: fullname: Sugimoto – start-page: 144 volume-title: Endosonography - what are the limits in gastroenterological diagnostics? year: 1991 ident: key-10.4103/2303-9027.187862-1 publication-title: Endoscopy contributor: fullname: Rösch – start-page: 973 volume-title: Diagnostic ability and factors affecting accuracy of endoscopic ultrasound-guided fine needle aspiration for pancreatic solid lesions: Japanese large single center experience year: 2013 ident: key-10.4103/2303-9027.187862-58 publication-title: J Gastroenterol contributor: fullname: Haba – start-page: 234 volume-title: Cytopathologic diagnoses of fine-needle aspirations from endoscopic ultrasound of the mediastinum: Reproducibility of the diagnoses and representativeness of aspirates from lymph nodes year: 2007 ident: key-10.4103/2303-9027.187862-72 publication-title: Cancer contributor: fullname: Skov – start-page: 322 volume-title: Endoscopic ultrasound-guided fine-needle aspiration of solid pancreatic masses with rapid on-site cytological evaluation by endosonographers without attendance of cytopathologists year: 2009 ident: key-10.4103/2303-9027.187862-62 publication-title: J Gastroenterol contributor: fullname: Hikichi – start-page: 172 volume-title: Endoscopic ultrasonography with guided fine needle aspiration biopsy in pancreatic disease year: 1992 ident: key-10.4103/2303-9027.187862-2 publication-title: Gastrointest Endosc contributor: fullname: Vilmann – start-page: 868 volume-title: Diagnostic efficacy of the cell block method in comparison with smear cytology of tissue samples obtained by endoscopic ultrasound-guided fine-needle aspiration year: 2010 ident: key-10.4103/2303-9027.187862-69 publication-title: J Gastroenterol contributor: fullname: Noda – start-page: 1075 volume-title: Rapid on-site evaluation of EUS-FNA by cytopathologist: An experience of a tertiary hospital year: 2013 ident: key-10.4103/2303-9027.187862-37 publication-title: Diagn Cytopathol contributor: fullname: Ecka – start-page: 2007 volume-title: Rapid on-site evaluation of endoscopic ultrasound core biopsy specimens has excellent specificity and positive predictive value for gastrointestinal lesions year: 2013 ident: key-10.4103/2303-9027.187862-57 publication-title: Dig Dis Sci contributor: fullname: Krishnan – start-page: S125 volume-title: Basic technique of FNA year: 2009 ident: key-10.4103/2303-9027.187862-65 publication-title: Gastrointest Endosc contributor: fullname: Irisawa – start-page: 1401 volume-title: "Wet suction technique (WEST)": A novel way to enhance the quality of EUS-FNA aspirate.Results of a prospective, single-blind, randomized, controlled trial using a 22-gauge needle for EUS-FNA of solid lesions year: 2015 ident: key-10.4103/2303-9027.187862-29 publication-title: Gastrointest Endosc contributor: fullname: Attam – start-page: 1433 volume-title: Diagnostic accuracy of endoscopic ultrasound-guided fine-needle aspiration for solid pancreatic lesion: A systematic review year: 2012 ident: key-10.4103/2303-9027.187862-56 publication-title: J Cancer Res Clin Oncol contributor: fullname: Chen – start-page: 190 volume-title: Learning, techniques, and complications of endoscopic ultrasound (EUS)-guided sampling in gastroenterology: European Society of Gastrointestinal Endoscopy (ESGE) Technical Guideline year: 2012 ident: key-10.4103/2303-9027.187862-68 publication-title: Endoscopy contributor: fullname: Polkowski – start-page: 177 volume-title: Macroscopic on-site quality evaluation of biopsy specimens to improve the diagnostic accuracy during EUS-guided FNA using a 19-gauge needle for solid lesions: A single-center prospective pilot study (MOSE study) year: 2015 ident: key-10.4103/2303-9027.187862-64 publication-title: Gastrointest Endosc contributor: fullname: Iwashita – start-page: 1739 volume-title: The prospective randomized, controlled trial of endoscopic ultrasound-guided fine-needle aspiration using 22G and 19G aspiration needles for solid pancreatic or peripancreatic masses year: 2010 ident: key-10.4103/2303-9027.187862-19 publication-title: Am J Gastroenterol contributor: fullname: Song – start-page: 159 volume-title: The presence of a cytopathologist increases the diagnostic accuracy of endoscopic ultrasound-guided fine needle aspiration cytology for pancreatic adenocarcinoma: A meta-analysis year: 2013 ident: key-10.4103/2303-9027.187862-60 publication-title: Cytopathology contributor: fullname: Hébert-Magee – start-page: 28 volume-title: Comparison of endoscopic ultrasound guided 22-gauge core needle with standard 25-gauge fine-needle aspiration for diagnosing solid pancreatic lesions year: 2015 ident: key-10.4103/2303-9027.187862-24 publication-title: Endosc Ultrasound contributor: fullname: Berzosa – ident: key-10.4103/2303-9027.187862-31 – ident: key-10.4103/2303-9027.187862-44 doi: 10.1016/j.gie.2014.04.012 – start-page: 174 volume-title: Comparison of two techniques for endoscopic ultrasonography fine-needle aspiration in solid pancreatic mass year: 2014 ident: key-10.4103/2303-9027.187862-47 publication-title: Endosc Ultrasound contributor: fullname: Mohammad – start-page: 60 volume-title: Contrast-enhanced harmonic endoscopic ultrasonography for pancreatobiliary diseases year: 2015 ident: key-10.4103/2303-9027.187862-50 publication-title: Dig Endosc contributor: fullname: Kitano – ident: key-10.4103/2303-9027.187862-8 – start-page: 246 volume-title: Contrast-enhanced endoscopic ultrasound in discrimination between focal pancreatitis and pancreatic cancer year: 2006 ident: key-10.4103/2303-9027.187862-52 publication-title: World J Gastroenterol contributor: fullname: Hocke – start-page: 17 volume-title: Endoscopic ultrasound-guided fine needle aspiration: The wet suction technique year: 2016 ident: key-10.4103/2303-9027.187862-30 publication-title: Endosc Ultrasound contributor: fullname: Villa – start-page: 475 volume-title: Optimal number of EUS-guided fine needle passes needed to obtain a correct diagnosis year: 2004 ident: key-10.4103/2303-9027.187862-34 publication-title: Gastrointest Endosc contributor: fullname: LeBlanc – start-page: 384 volume-title: Prospective comparative study of the EUS guided 25-gauge FNA needle with the 19-gauge trucut needle and 22-gauge FNA needle in patients with solid pancreatic masses year: 2009 ident: key-10.4103/2303-9027.187862-15 publication-title: J Gastroenterol Hepatol contributor: fullname: Sakamoto – start-page: 1087 volume-title: Endosonography-guided fine-needle aspiration biopsy: Diagnostic accuracy and complication assessment year: 1997 ident: key-10.4103/2303-9027.187862-3 publication-title: Gastroenterology contributor: fullname: Wiersema – start-page: 1093 volume-title: EUS-guided FNA of solid pancreatic masses: A prospective, randomized trial comparing 22-gauge and 25-gauge needles year: 2009 ident: key-10.4103/2303-9027.187862-16 publication-title: Gastrointest Endosc contributor: fullname: Siddiqui – start-page: 499 volume-title: Randomized controlled trial of endoscopic ultrasound-guided fine-needle sampling with or without suction for better cytological diagnosis year: 2009 ident: key-10.4103/2303-9027.187862-45 publication-title: Scand J Gastroenterol contributor: fullname: Puri – start-page: 62 volume-title: Pitfalls in endoscopic ultrasound-guided fine-needle aspiration and how to avoid them year: 2005 ident: key-10.4103/2303-9027.187862-70 publication-title: Adv Anat Pathol contributor: fullname: Stelow – ident: key-10.4103/2303-9027.187862-38 doi: 10.1016/j.gie.2015.03.1807 – start-page: 91 volume-title: Diagnosis of pancreatic neoplasia with EUS and FNA: A report of accuracy year: 2010 ident: key-10.4103/2303-9027.187862-35 publication-title: Gastrointest Endosc contributor: fullname: Turner |
SSID | ssib044735838 ssib046616679 ssj0001104800 |
Score | 2.1951978 |
SecondaryResourceType | review_article |
Snippet | Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) is widely used to obtain a definitive diagnosis of pancreatic tumors. Good results have been... |
SourceID | pubmedcentral proquest gale crossref pubmed wolterskluwer |
SourceType | Open Access Repository Aggregation Database Index Database Publisher |
StartPage | 225 |
SubjectTerms | Diagnosis Endoscopic ultrasonography Innovations Management Medical care quality Needle biopsy Pancreatic cancer Review |
SummonAdditionalLinks | – databaseName: Scholars Portal Open Access Journals dbid: M48 link: http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwtR1da9UwNMh8EUQmflWnRhDEh16bJk2bJxmyMQR9kA32FpI01Yt3rd62bPv3npP03t2OvfrapEl6PnLO6fki5H3eWFHkxgMjFTwVyvFUVUak0lXWFo4pm2Fy8rfv8uRMfD0vzm_SoycA9neadthP6my9Wlz9vf4MDA_660KwjH8CLRp2APtqwaqywgv5fi7ATsdAvhtlX2CT3R0foQDJJOXkowp_ZBjmV2ehG920YPRr3rnJTI7dvs13xNntUMuHlx26wfvfIQp-R5Yd75NHkxJKDyPVPCb3fPuEXB41DboP6NDRZfjV4Cloh7SOwXgwlRrnxrVx17RrqG_rDlNa4PG4gk177M-U_hyXta9pA7pr2oJgXHlqoi8f8E9hfQq3T1RUHR3Gi27dPyWnx0enX07SqS1D6sBYGVLGSuu84oqJwoIAlMI0pqllyHItheFwGM-Y4a4sZV2oDF4rpcml91bljj8je23X-heEgnbPVVYzJvNGZLZSXoii5MZYb0ylqoR83MBY_4nFNzQYLYgPjfjQiA8d8ZGQt4gEHdNHt3yrD4XMeIFV0RLyIcxAWgKwODMlIMBZsAbWbObBbCZwnJsNv9sgWuMQhqm1vht7OEroNwpSPyHPI-K3B8dC-hwYIiHljCS2E7DQ93ykXf4KBb8FVsnP4BN_zIhHX8SMyRlM0h2YaLis9UQ8euj0RDwaiEdviOfl_1j0FXkAiqWMYc0HZG9Yj_41KG-DfRN48h-2oUA0 priority: 102 providerName: Scholars Portal – databaseName: Medknow Open Access Medical Journals dbid: W3E link: http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwtR1di9QwMBzniyBy4lf11AiC-FBtmjRtKT4cssch6IOceD6FNE29xdtWti3H_fubSdJle---NtnudD4yM5kvQt6lbS2yVFsQpIzHojQ8LgstYmmKus4MK-sEi5O_fZdnP8XXi-zigMxev8uqnIaAR3dSBwy6ui4nF2A0wwvBnapugBnwkk9WQZSzykMrqiCOaVb5Ux0Mh0pPYJCOn3_rja5t5ZoSgbN_D_0yHPrwi69mThQ4kHcvnihAi0kZ4lnu9oZhLXbiJtcFaHwMVLCEf9o9-8iKvJDpQufdPfn3VN_dtMwH1z2GzIe_LmN-T--dHpGHwWClJx4_j8iB7R6T61XbYqiBjj1du2sJS8GSpI1P3IOtVBszbbW5oX1Lbdf0WP4Cj6cr-NMBZznFf6Z1Yxvagp0bd6BEryzVPu4PvELh_RROKm_UGjpOm347PCHnp6vzL2dxGOEQG3BsxpixvDa25CUTWQ3KUgrd6raRriI2F5oDMJYxzU2eyyYrE_hZLnUqra3L1PCn5LDrO_ucUPAEeJk0jMm0FUldlFaILOcaSKl1URYR-TDjWP3zjToUODhID4X0UEgP5ekRkTdIBOVLTXcyrk6ETHiGHdQi8t7tQCkHtBgdihUAFuyXtdh5vNgJ0mkWy29nQitcwpS2zvbTAKC42aRgIUTkmSf8DnBsus9BeCKSL1hitwGbgi9XuvWlaw4usKN-Ap_4Y8E8auOrKxc4ifdwokBWVGAeNfYqMI8C5lEz87z4Hy99Se6jCPsU6GNyOG4n-woMvbF-7WTyFuN8UNw priority: 102 providerName: Wolters Kluwer Health |
Title | Efforts to improve the diagnostic accuracy of endoscopic ultrasound-guided fine-needle aspiration for pancreatic tumors |
URI | http://www.eusjournal.com/article.asp?issn=2303-9027;year=2016;volume=5;issue=4;spage=225;epage=232;aulast=Yamabe;type=0 https://www.ncbi.nlm.nih.gov/pubmed/27503153 https://search.proquest.com/docview/1810556801 https://pubmed.ncbi.nlm.nih.gov/PMC4989402 |
Volume | 5 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV3Na9swFBdtT4MxNvblres0GIwdnFiWLNvHUlLKIGOMjvUmJFneQhO7JDZll_3te0-yQ9zjLj5YL_aL3k96T35fhHxMayOyVDtYSBmPRWl5XBZaxNIWxmSWlSbB5OTlV3n1Q3y5yW6OSDbmwvigfWtWs2a9mTWr3z628m5j52Oc2Pzb8kJg1fAknR-TYwDo9IgusJfugStQgAKScnBF-Q8vDNOoE990LgHO4FwW3JeCJXy-vzdjRQ7WPhYLRlcfy_hEcz3cvw8U2MPgysf3LTq-d7c-7v1Ae10-JU8Gs5Oeh7_3jBy55jm5X9Q1Ogxo19KV_7jgKNiDtArhd0BKtbX9Vts_tK2pa6oWk1jgdr-Gl-6wI1P8q19VrqI1WKtxA6pw7agO3nuQOIXnU9hvgmlqaddv2u3uBbm-XFxfXMVDI4bYwvGkixnLjXUlL5nIDKg8KXSt60r6vNZcaA7MOMY0t3kuq6xM4Ge51Kl0zpSp5S_JSdM27jWhYM_zMqkYk2ktElOUTogs51obp3VRFhH5PM6xugvlNhQcU1A0CkWjUDQqiCYi71EIKiSM7leqOhcy4RnWQYvIJ0-BaxWmxeoh5QB4wapXE8rTCSWsMTsZ_jAKWuEQBqY1ru13wIrvMAp6PiKvguD3jI_AiUg-gcSeAEt7T0cA8b7E94DwiHyfgEdtQo7kZE7igzlRsD2rATyqa9UAHgXgUSN43vw3O2_JI7AXZYhWPiUn3bZ378Am68wZOV6KAq9_F2d-PcL1J1_8A-4hNkU |
link.rule.ids | 230,315,730,783,787,888,2228,24330,27470,27936,27937,53804,53806 |
linkProvider | National Library of Medicine |
linkToHtml | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1bb9MwFLbGeAAJcRG3wGBGQkI8JI1jx0kep2lTgXVCqKC9WbbjQLU2mdpEE_x6ju2kavoGr7Fbnfh8PpecG0Lvk0qxNJEGLlJKQ1ZoGha5ZCHXuVKpJoWKbXHy7JJPv7PPV-nVAUqHWhiXtK_VIqqXq6he_HK5lTcrPRnyxCZfZ6fMdg2Pk8kddBfua8zGTjqz03R3goEMVBDnfTDKfXohtpA6dmPnYqANPDMfwGQkppPts4jkGdj7tl2wDfaRlI50174E31Fh--mVD24bG_reXLvM9x39df4I_Rje3KetXEddqyL9Z68p5D8fzWP0sLdo8YlffoIOTP0U3Z5VlY1F4LbBC_fdwmAwNXHpM_tgK5Zad2upf-OmwqYuG1sfA4-7JbzNxg57Cn92i9KUuAJDOKxByy4Nlj4xAMCE4f8xiDJv9WrcdqtmvXmG5udn89Np2M94CDV4Pm1ISKa0KWhBWKpAm3ImK1mV3JXMZkxSIMYQIqnOMl6mRQw_y7hMuDGqSDR9jg7rpjYvEQZXgRZxSQhPKharvDCMpRmVUhkp8yIP0MeBeeLGd_IQ4AFZngvLc2F5LjzPA3RsuSt8LepWCIgTxmOa2hZrAfrgdlgxAMeiZV_NALTYhlqjnUejnXB99Wj53YAgYZdszlttmm4DpLjhpWBCBOiFR9SW8AGRAcpGWNtusF3DxyuAGNc9vEdIgL6NUClWvvxydCbhzpkIkPyiB49oG9GDRwB4xACeV_9NzjG6N53PLsTFp8svr9F9MEu5T4o-QoftujNvwPRr1Vt30f8CupZVRA |
linkToPdf | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV3da9swEBdbB2NQ9sG-3HWrBoOxB8eWJcv2Y-kauo-WMjooexGSLG-hiR0Sm7L99TtJdojz2FfrEs66n3R3vi-EPiSVYmkiDRyklIas0DQscslCrnOlUk0KFdvi5PMLfvaTfb1Or7dGfbmkfa1mk3q-mNSzPy63crnQ0ZAnFl2enzDbNTxOomVZRffRAzizMR876sxO1N0KCDJQQ5z3ASn3-YXYYurYjZ6LgT_wznwQk5GYRptnE5JnYPPblsE24EdSOtJfu7f4lhrbTbHcv21s-Ht947Lft3TY9An6Nby9T125mXStmuh_O40h77Q9T9Hj3rLFx57kGbpn6ufo9rSqbEwCtw2eue8XBoPJiUuf4QekWGrdraT-i5sKm7psbJ0MPO7m8EZrO_Qp_N3NSlPiCgzisAZtOzdY-gQBABWG_8dwpXnrV-O2WzSr9Qt0NT29OjkL-1kPoQYPqA0JyZQ2BS0ISxVoVc5kJauSu9LZjEkKzBhCJNVZxsu0iOFnGZcJN0YViaYv0V7d1OY1wuAy0CIuCeFJxWKVF4axNKNSKiNlXuQB-jQIUCx9Rw8BnpCVu7ByF1buwss9QEdWwsLXpG4uA3HMeExT22otQB8dhb0OYFu07KsagBfbWGtEeTiihGOsR8vvBxQJu2Rz32rTdGtgxQ0xBVMiQK88qjaMD6gMUDbC24bAdg8frwBqXBfxHiUB-jFCplj4MszRnoRbeyJAA4gePKJtRA8eAeARA3gO7szOEXp4-Xkqvn-5-PYGPQLrlPvc6EO016468xYswFa9c2f9P1FUV8Q |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Efforts+to+improve+the+diagnostic+accuracy+of+endoscopic+ultrasound-guided+fine-needle+aspiration+for+pancreatic+tumors&rft.jtitle=Endoscopic+Ultrasound&rft.au=Yamabe%2C+Akane&rft.au=Irisawa%2C+Atsushi&rft.au=Bhutani%2C+Manoop&rft.au=Shibukawa%2C+Goro&rft.date=2016-07-01&rft.pub=Medknow+Publications+and+Media+Pvt.+Ltd&rft.issn=2303-9027&rft.volume=5&rft.issue=4&rft.spage=225&rft_id=info:doi/10.4103%2F2303-9027.187862&rft.externalDocID=A460356360 |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=2303-9027&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=2303-9027&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=2303-9027&client=summon |