Blood flow dynamics with four-dimensional flow cardiovascular magnetic resonance in patients with aortic stenosis before and after transcatheter aortic valve replacement

Pre- and post-procedural hemodynamic changes which could affect adverse outcomes in aortic stenosis (AS) patients who undergo transcatheter aortic valve replacement (TAVR) have not been well investigated. Four-dimensional (4D) flow cardiovascular magnetic resonance (CMR) enables accurate analysis of...

Full description

Saved in:
Bibliographic Details
Published inJournal of cardiovascular magnetic resonance Vol. 23; no. 1; pp. 81 - 15
Main Authors Komoriyama, Hirokazu, Kamiya, Kiwamu, Nagai, Toshiyuki, Oyama-Manabe, Noriko, Tsuneta, Satonori, Kobayashi, Yuta, Kato, Yoshiya, Sarashina, Miwa, Omote, Kazunori, Konishi, Takao, Sato, Takuma, Tsujinaga, Shingo, Iwano, Hiroyuki, Shingu, Yasushige, Wakasa, Satoru, Anzai, Toshihisa
Format Journal Article
LanguageEnglish
Published England BioMed Central Ltd 28.06.2021
BioMed Central
Elsevier
Subjects
Online AccessGet full text

Cover

Loading…
Abstract Pre- and post-procedural hemodynamic changes which could affect adverse outcomes in aortic stenosis (AS) patients who undergo transcatheter aortic valve replacement (TAVR) have not been well investigated. Four-dimensional (4D) flow cardiovascular magnetic resonance (CMR) enables accurate analysis of blood flow dynamics such as flow velocity, flow pattern, wall shear stress (WSS), and energy loss (EL). We sought to examine the changes in blood flow dynamics of patients with severe AS who underwent TAVR. We examined 32 consecutive severe AS patients who underwent TAVR between May 2018 and June 2019 (17 men, 82 ± 5 years, median left ventricular ejection fraction 61%, 6 self-expanding valve), after excluding those without CMR because of a contraindication or inadequate imaging from the analyses. We analyzed blood flow patterns, WSS and EL in the ascending aorta (AAo), and those changes before and after TAVR using 4D flow CMR. After TAVR, semi-quantified helical flow in the AAo was significantly decreased (1.4 ± 0.6 vs. 1.9 ± 0.8, P = 0.002), whereas vortical flow and eccentricity showed no significant changes. WSS along the ascending aortic circumference was significantly decreased in the left (P = 0.038) and left anterior (P = 0.033) wall at the basal level, right posterior (P = 0.011) and left (P = 0.010) wall at the middle level, and right (P = 0.012), left posterior (P = 0.019) and left anterior (P = 0.028) wall at the upper level. EL in the AAo was significantly decreased (15.6 [10.8-25.1 vs. 25.8 [18.6-36.2]] mW, P = 0.012). Furthermore, a significant negative correlation was observed between EL and effective orifice area index after TAVR (r = - 0.38, P = 0.034). In severe AS patients undergoing TAVR, 4D flow CMR demonstrates that TAVR improves blood flow dynamics, especially when a larger effective orifice area index is obtained.
AbstractList Background Pre- and post-procedural hemodynamic changes which could affect adverse outcomes in aortic stenosis (AS) patients who undergo transcatheter aortic valve replacement (TAVR) have not been well investigated. Four-dimensional (4D) flow cardiovascular magnetic resonance (CMR) enables accurate analysis of blood flow dynamics such as flow velocity, flow pattern, wall shear stress (WSS), and energy loss (EL). We sought to examine the changes in blood flow dynamics of patients with severe AS who underwent TAVR. Methods We examined 32 consecutive severe AS patients who underwent TAVR between May 2018 and June 2019 (17 men, 82 ± 5 years, median left ventricular ejection fraction 61%, 6 self-expanding valve), after excluding those without CMR because of a contraindication or inadequate imaging from the analyses. We analyzed blood flow patterns, WSS and EL in the ascending aorta (AAo), and those changes before and after TAVR using 4D flow CMR. Results After TAVR, semi-quantified helical flow in the AAo was significantly decreased (1.4 ± 0.6 vs. 1.9 ± 0.8, P = 0.002), whereas vortical flow and eccentricity showed no significant changes. WSS along the ascending aortic circumference was significantly decreased in the left (P = 0.038) and left anterior (P = 0.033) wall at the basal level, right posterior (P = 0.011) and left (P = 0.010) wall at the middle level, and right (P = 0.012), left posterior (P = 0.019) and left anterior (P = 0.028) wall at the upper level. EL in the AAo was significantly decreased (15.6 [10.8–25.1 vs. 25.8 [18.6–36.2]] mW, P = 0.012). Furthermore, a significant negative correlation was observed between EL and effective orifice area index after TAVR (r = − 0.38, P = 0.034). Conclusions In severe AS patients undergoing TAVR, 4D flow CMR demonstrates that TAVR improves blood flow dynamics, especially when a larger effective orifice area index is obtained.
Pre- and post-procedural hemodynamic changes which could affect adverse outcomes in aortic stenosis (AS) patients who undergo transcatheter aortic valve replacement (TAVR) have not been well investigated. Four-dimensional (4D) flow cardiovascular magnetic resonance (CMR) enables accurate analysis of blood flow dynamics such as flow velocity, flow pattern, wall shear stress (WSS), and energy loss (EL). We sought to examine the changes in blood flow dynamics of patients with severe AS who underwent TAVR. We examined 32 consecutive severe AS patients who underwent TAVR between May 2018 and June 2019 (17 men, 82 [+ or -] 5 years, median left ventricular ejection fraction 61%, 6 self-expanding valve), after excluding those without CMR because of a contraindication or inadequate imaging from the analyses. We analyzed blood flow patterns, WSS and EL in the ascending aorta (AAo), and those changes before and after TAVR using 4D flow CMR. After TAVR, semi-quantified helical flow in the AAo was significantly decreased (1.4 [+ or -] 0.6 vs. 1.9 [+ or -] 0.8, P = 0.002), whereas vortical flow and eccentricity showed no significant changes. WSS along the ascending aortic circumference was significantly decreased in the left (P = 0.038) and left anterior (P = 0.033) wall at the basal level, right posterior (P = 0.011) and left (P = 0.010) wall at the middle level, and right (P = 0.012), left posterior (P = 0.019) and left anterior (P = 0.028) wall at the upper level. EL in the AAo was significantly decreased (15.6 [10.8-25.1 vs. 25.8 [18.6-36.2]] mW, P = 0.012). Furthermore, a significant negative correlation was observed between EL and effective orifice area index after TAVR (r = - 0.38, P = 0.034). In severe AS patients undergoing TAVR, 4D flow CMR demonstrates that TAVR improves blood flow dynamics, especially when a larger effective orifice area index is obtained.
Pre- and post-procedural hemodynamic changes which could affect adverse outcomes in aortic stenosis (AS) patients who undergo transcatheter aortic valve replacement (TAVR) have not been well investigated. Four-dimensional (4D) flow cardiovascular magnetic resonance (CMR) enables accurate analysis of blood flow dynamics such as flow velocity, flow pattern, wall shear stress (WSS), and energy loss (EL). We sought to examine the changes in blood flow dynamics of patients with severe AS who underwent TAVR. We examined 32 consecutive severe AS patients who underwent TAVR between May 2018 and June 2019 (17 men, 82 ± 5 years, median left ventricular ejection fraction 61%, 6 self-expanding valve), after excluding those without CMR because of a contraindication or inadequate imaging from the analyses. We analyzed blood flow patterns, WSS and EL in the ascending aorta (AAo), and those changes before and after TAVR using 4D flow CMR. After TAVR, semi-quantified helical flow in the AAo was significantly decreased (1.4 ± 0.6 vs. 1.9 ± 0.8, P = 0.002), whereas vortical flow and eccentricity showed no significant changes. WSS along the ascending aortic circumference was significantly decreased in the left (P = 0.038) and left anterior (P = 0.033) wall at the basal level, right posterior (P = 0.011) and left (P = 0.010) wall at the middle level, and right (P = 0.012), left posterior (P = 0.019) and left anterior (P = 0.028) wall at the upper level. EL in the AAo was significantly decreased (15.6 [10.8-25.1 vs. 25.8 [18.6-36.2]] mW, P = 0.012). Furthermore, a significant negative correlation was observed between EL and effective orifice area index after TAVR (r = - 0.38, P = 0.034). In severe AS patients undergoing TAVR, 4D flow CMR demonstrates that TAVR improves blood flow dynamics, especially when a larger effective orifice area index is obtained.
Pre- and post-procedural hemodynamic changes which could affect adverse outcomes in aortic stenosis (AS) patients who undergo transcatheter aortic valve replacement (TAVR) have not been well investigated. Four-dimensional (4D) flow cardiovascular magnetic resonance (CMR) enables accurate analysis of blood flow dynamics such as flow velocity, flow pattern, wall shear stress (WSS), and energy loss (EL). We sought to examine the changes in blood flow dynamics of patients with severe AS who underwent TAVR.BACKGROUNDPre- and post-procedural hemodynamic changes which could affect adverse outcomes in aortic stenosis (AS) patients who undergo transcatheter aortic valve replacement (TAVR) have not been well investigated. Four-dimensional (4D) flow cardiovascular magnetic resonance (CMR) enables accurate analysis of blood flow dynamics such as flow velocity, flow pattern, wall shear stress (WSS), and energy loss (EL). We sought to examine the changes in blood flow dynamics of patients with severe AS who underwent TAVR.We examined 32 consecutive severe AS patients who underwent TAVR between May 2018 and June 2019 (17 men, 82 ± 5 years, median left ventricular ejection fraction 61%, 6 self-expanding valve), after excluding those without CMR because of a contraindication or inadequate imaging from the analyses. We analyzed blood flow patterns, WSS and EL in the ascending aorta (AAo), and those changes before and after TAVR using 4D flow CMR.METHODSWe examined 32 consecutive severe AS patients who underwent TAVR between May 2018 and June 2019 (17 men, 82 ± 5 years, median left ventricular ejection fraction 61%, 6 self-expanding valve), after excluding those without CMR because of a contraindication or inadequate imaging from the analyses. We analyzed blood flow patterns, WSS and EL in the ascending aorta (AAo), and those changes before and after TAVR using 4D flow CMR.After TAVR, semi-quantified helical flow in the AAo was significantly decreased (1.4 ± 0.6 vs. 1.9 ± 0.8, P = 0.002), whereas vortical flow and eccentricity showed no significant changes. WSS along the ascending aortic circumference was significantly decreased in the left (P = 0.038) and left anterior (P = 0.033) wall at the basal level, right posterior (P = 0.011) and left (P = 0.010) wall at the middle level, and right (P = 0.012), left posterior (P = 0.019) and left anterior (P = 0.028) wall at the upper level. EL in the AAo was significantly decreased (15.6 [10.8-25.1 vs. 25.8 [18.6-36.2]] mW, P = 0.012). Furthermore, a significant negative correlation was observed between EL and effective orifice area index after TAVR (r = - 0.38, P = 0.034).RESULTSAfter TAVR, semi-quantified helical flow in the AAo was significantly decreased (1.4 ± 0.6 vs. 1.9 ± 0.8, P = 0.002), whereas vortical flow and eccentricity showed no significant changes. WSS along the ascending aortic circumference was significantly decreased in the left (P = 0.038) and left anterior (P = 0.033) wall at the basal level, right posterior (P = 0.011) and left (P = 0.010) wall at the middle level, and right (P = 0.012), left posterior (P = 0.019) and left anterior (P = 0.028) wall at the upper level. EL in the AAo was significantly decreased (15.6 [10.8-25.1 vs. 25.8 [18.6-36.2]] mW, P = 0.012). Furthermore, a significant negative correlation was observed between EL and effective orifice area index after TAVR (r = - 0.38, P = 0.034).In severe AS patients undergoing TAVR, 4D flow CMR demonstrates that TAVR improves blood flow dynamics, especially when a larger effective orifice area index is obtained.CONCLUSIONSIn severe AS patients undergoing TAVR, 4D flow CMR demonstrates that TAVR improves blood flow dynamics, especially when a larger effective orifice area index is obtained.
Background Pre- and post-procedural hemodynamic changes which could affect adverse outcomes in aortic stenosis (AS) patients who undergo transcatheter aortic valve replacement (TAVR) have not been well investigated. Four-dimensional (4D) flow cardiovascular magnetic resonance (CMR) enables accurate analysis of blood flow dynamics such as flow velocity, flow pattern, wall shear stress (WSS), and energy loss (EL). We sought to examine the changes in blood flow dynamics of patients with severe AS who underwent TAVR. Methods We examined 32 consecutive severe AS patients who underwent TAVR between May 2018 and June 2019 (17 men, 82 [+ or -] 5 years, median left ventricular ejection fraction 61%, 6 self-expanding valve), after excluding those without CMR because of a contraindication or inadequate imaging from the analyses. We analyzed blood flow patterns, WSS and EL in the ascending aorta (AAo), and those changes before and after TAVR using 4D flow CMR. Results After TAVR, semi-quantified helical flow in the AAo was significantly decreased (1.4 [+ or -] 0.6 vs. 1.9 [+ or -] 0.8, P = 0.002), whereas vortical flow and eccentricity showed no significant changes. WSS along the ascending aortic circumference was significantly decreased in the left (P = 0.038) and left anterior (P = 0.033) wall at the basal level, right posterior (P = 0.011) and left (P = 0.010) wall at the middle level, and right (P = 0.012), left posterior (P = 0.019) and left anterior (P = 0.028) wall at the upper level. EL in the AAo was significantly decreased (15.6 [10.8-25.1 vs. 25.8 [18.6-36.2]] mW, P = 0.012). Furthermore, a significant negative correlation was observed between EL and effective orifice area index after TAVR (r = - 0.38, P = 0.034). Conclusions In severe AS patients undergoing TAVR, 4D flow CMR demonstrates that TAVR improves blood flow dynamics, especially when a larger effective orifice area index is obtained. Keywords: Four-dimensional flow cardiovascular magnetic resonance, Aortic stenosis, Transcatheter aortic valve replacement, Blood flow dynamics
Abstract Background Pre- and post-procedural hemodynamic changes which could affect adverse outcomes in aortic stenosis (AS) patients who undergo transcatheter aortic valve replacement (TAVR) have not been well investigated. Four-dimensional (4D) flow cardiovascular magnetic resonance (CMR) enables accurate analysis of blood flow dynamics such as flow velocity, flow pattern, wall shear stress (WSS), and energy loss (EL). We sought to examine the changes in blood flow dynamics of patients with severe AS who underwent TAVR. Methods We examined 32 consecutive severe AS patients who underwent TAVR between May 2018 and June 2019 (17 men, 82 ± 5 years, median left ventricular ejection fraction 61%, 6 self-expanding valve), after excluding those without CMR because of a contraindication or inadequate imaging from the analyses. We analyzed blood flow patterns, WSS and EL in the ascending aorta (AAo), and those changes before and after TAVR using 4D flow CMR. Results After TAVR, semi-quantified helical flow in the AAo was significantly decreased (1.4 ± 0.6 vs. 1.9 ± 0.8, P = 0.002), whereas vortical flow and eccentricity showed no significant changes. WSS along the ascending aortic circumference was significantly decreased in the left (P = 0.038) and left anterior (P = 0.033) wall at the basal level, right posterior (P = 0.011) and left (P = 0.010) wall at the middle level, and right (P = 0.012), left posterior (P = 0.019) and left anterior (P = 0.028) wall at the upper level. EL in the AAo was significantly decreased (15.6 [10.8–25.1 vs. 25.8 [18.6–36.2]] mW, P = 0.012). Furthermore, a significant negative correlation was observed between EL and effective orifice area index after TAVR (r = − 0.38, P = 0.034). Conclusions In severe AS patients undergoing TAVR, 4D flow CMR demonstrates that TAVR improves blood flow dynamics, especially when a larger effective orifice area index is obtained.
ArticleNumber 81
Audience Academic
Author Tsujinaga, Shingo
Sato, Takuma
Anzai, Toshihisa
Wakasa, Satoru
Konishi, Takao
Nagai, Toshiyuki
Kato, Yoshiya
Komoriyama, Hirokazu
Tsuneta, Satonori
Kamiya, Kiwamu
Sarashina, Miwa
Shingu, Yasushige
Kobayashi, Yuta
Oyama-Manabe, Noriko
Iwano, Hiroyuki
Omote, Kazunori
Author_xml – sequence: 1
  givenname: Hirokazu
  surname: Komoriyama
  fullname: Komoriyama, Hirokazu
– sequence: 2
  givenname: Kiwamu
  surname: Kamiya
  fullname: Kamiya, Kiwamu
– sequence: 3
  givenname: Toshiyuki
  orcidid: 0000-0002-1043-0608
  surname: Nagai
  fullname: Nagai, Toshiyuki
– sequence: 4
  givenname: Noriko
  surname: Oyama-Manabe
  fullname: Oyama-Manabe, Noriko
– sequence: 5
  givenname: Satonori
  surname: Tsuneta
  fullname: Tsuneta, Satonori
– sequence: 6
  givenname: Yuta
  surname: Kobayashi
  fullname: Kobayashi, Yuta
– sequence: 7
  givenname: Yoshiya
  surname: Kato
  fullname: Kato, Yoshiya
– sequence: 8
  givenname: Miwa
  surname: Sarashina
  fullname: Sarashina, Miwa
– sequence: 9
  givenname: Kazunori
  surname: Omote
  fullname: Omote, Kazunori
– sequence: 10
  givenname: Takao
  surname: Konishi
  fullname: Konishi, Takao
– sequence: 11
  givenname: Takuma
  surname: Sato
  fullname: Sato, Takuma
– sequence: 12
  givenname: Shingo
  surname: Tsujinaga
  fullname: Tsujinaga, Shingo
– sequence: 13
  givenname: Hiroyuki
  surname: Iwano
  fullname: Iwano, Hiroyuki
– sequence: 14
  givenname: Yasushige
  surname: Shingu
  fullname: Shingu, Yasushige
– sequence: 15
  givenname: Satoru
  surname: Wakasa
  fullname: Wakasa, Satoru
– sequence: 16
  givenname: Toshihisa
  surname: Anzai
  fullname: Anzai, Toshihisa
BackLink https://www.ncbi.nlm.nih.gov/pubmed/34176516$$D View this record in MEDLINE/PubMed
BookMark eNp9kstu1DAUhiNURC_wAixQJCTEJsV2nDjeIJWKS6VKbEBiZ534MuPKYw-2M9U8Em-J0xlKp0Ioi8TO9__nHPs_rY588LqqXmJ0jvHQv0uY8H5oEMENQozhZvukOsFdSxpK-I-j8o04a_qesuPqNKUbhDBniD2rjluKWd_h_qT69cGFoGrjwm2tth5WVqb61uZlbcIUG2VX2icbPLgdIyEqGzaQ5OQg1itYeJ2trKNOBfJS19bXa8hW-7w3ghBnImXtQ7KpHrUJUdfgVQ0m61jnCD5JyEs9r_b4BtxGF9u1A6lLE_l59dSAS_rF_n1Wff_08dvll-b66-ery4vrRvbtkJtOcUyxUsDoQGnHDRowHRFVgBQyhiAOLSWGtIh3um2N1tBh0nadVJxxxdqz6mrnqwLciHW0K4hbEcCKu40QFwLmDp0WhvZtNyo0DmNHNUejGhhmZDSImYGOvHi933mtp3GllSxjRHAHpod_vF2KRdiIgbSsdF8M3u4NYvg56ZTFyiapnQOvw5QE6cqIpSjpC_r6EXpTbrBc3Ex1ZCCUofYvtYAygPUmlLpyNhUXPSOk54jM1Pk_qPIoXQJSUmhs2T8QvHkgWGpweZmCm3KJTjoEXz08kfuj-JPIApAdIGNIKWpzj2Ak5tiLXexFib24i73YFtHwSCRthrl46du6_0l_AxfVCbA
CitedBy_id crossref_primary_10_2463_mrms_rev_2021_0030
crossref_primary_10_1016_j_jaccas_2022_01_009
crossref_primary_10_1186_s12968_023_00970_9
crossref_primary_10_1016_j_mri_2024_03_010
crossref_primary_10_3390_jcdd10050187
crossref_primary_10_1186_s12872_024_04394_w
crossref_primary_10_3390_jcm12196301
crossref_primary_10_1177_30494826241296678
crossref_primary_10_1016_j_shj_2024_100300
crossref_primary_10_1097_HPC_0000000000000321
crossref_primary_10_1007_s11239_023_02835_5
crossref_primary_10_1016_j_ejrad_2023_110722
crossref_primary_10_1016_j_jjcc_2024_10_001
crossref_primary_10_5758_vsi_240066
crossref_primary_10_1016_j_metrad_2024_100123
Cites_doi 10.1016/j.ijcard.2013.11.034
10.1093/icvts/ivy271
10.1016/j.jacc.2012.08.1039
10.1002/mrm.24962
10.1097/00004728-200407000-00005
10.1161/CIRCIMAGING.115.004038
10.1002/mrm.27684
10.1007/s11748-017-0834-5
10.1161/CIR.0000000000000503
10.1186/s12968-018-0451-1
10.1016/j.jacc.2018.09.001
10.1093/ehjci/jev035
10.1016/j.artres.2012.12.002
10.1056/NEJMoa1816885
10.1002/mrm.21778
10.1007/s00380-017-0979-2
10.1002/jmri.23610
10.1016/j.jacc.2014.02.612
10.1146/annurev.bioeng.6.040803.140111
10.1056/NEJMoa1814052
10.1007/s10554-015-0792-x
10.1161/JAHA.118.011724
10.1016/S0735-1097(98)00374-X
10.1038/srep32316
10.1016/j.jjcc.2015.09.017
10.1007/s00330-018-5672-z
10.1002/mrm.25188
10.1161/01.CIR.88.5.2235
10.1016/j.echo.2009.07.013
10.1002/jmri.24560
10.1186/s12968-015-0174-5
10.1007/s10237-010-0238-2
10.1016/j.jtcvs.2014.05.014
10.1161/CIRCULATIONAHA.112.078857
10.1161/01.CIR.76.1.90
10.1007/s00330-011-2353-6
10.1002/mrm.27386
10.1002/jmri.25956
10.1152/ajpheart.00694.2018
10.1016/j.jcmg.2011.05.004
10.1002/jmri.23936
10.1371/journal.pone.0163316
10.1016/j.jcmg.2018.10.034
10.1016/j.jacc.2013.02.087
ContentType Journal Article
Copyright COPYRIGHT 2021 BioMed Central Ltd.
2021. This work is licensed under http://creativecommons.org/licenses/by/4.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.
The Author(s) 2021
Copyright_xml – notice: COPYRIGHT 2021 BioMed Central Ltd.
– notice: 2021. This work is licensed under http://creativecommons.org/licenses/by/4.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.
– notice: The Author(s) 2021
DBID AAYXX
CITATION
CGR
CUY
CVF
ECM
EIF
NPM
3V.
7SC
7SP
7U5
7X7
7XB
88E
8FD
8FE
8FG
8FH
8FI
8FJ
8FK
ABUWG
AFKRA
ARAPS
AZQEC
BBNVY
BENPR
BGLVJ
BHPHI
CCPQU
DWQXO
FR3
FYUFA
GHDGH
GNUQQ
HCIFZ
JQ2
K9.
L7M
LK8
L~C
L~D
M0S
M1P
M7P
M7Z
P5Z
P62
P64
PHGZM
PHGZT
PIMPY
PJZUB
PKEHL
PPXIY
PQEST
PQGLB
PQQKQ
PQUKI
PRINS
7X8
5PM
DOA
DOI 10.1186/s12968-021-00771-y
DatabaseName CrossRef
Medline
MEDLINE
MEDLINE (Ovid)
MEDLINE
MEDLINE
PubMed
ProQuest Central (Corporate)
Computer and Information Systems Abstracts
Electronics & Communications Abstracts
Solid State and Superconductivity Abstracts
Health & Medical Collection
ProQuest Central (purchase pre-March 2016)
Medical Database (Alumni Edition)
Technology Research Database
ProQuest SciTech Collection
ProQuest Technology Collection
ProQuest Natural Science Collection
Hospital Premium Collection
Hospital Premium Collection (Alumni Edition)
ProQuest Central (Alumni) (purchase pre-March 2016)
ProQuest Central (Alumni)
ProQuest Central UK/Ireland
Advanced Technologies & Aerospace Collection
ProQuest Central Essentials
Biological Science Collection
ProQuest Central
Technology Collection
Natural Science Collection
ProQuest One Community College
ProQuest Central Korea
Engineering Research Database
Health Research Premium Collection
Health Research Premium Collection (Alumni)
ProQuest Central Student
SciTech Premium Collection
ProQuest Computer Science Collection
ProQuest Health & Medical Complete (Alumni)
Advanced Technologies Database with Aerospace
Biological Sciences
Computer and Information Systems Abstracts – Academic
Computer and Information Systems Abstracts Professional
Health & Medical Collection (Alumni)
Medical Database ProQuest
Biological Science Database
Biochemistry Abstracts 1
Advanced Technologies & Aerospace Database
ProQuest Advanced Technologies & Aerospace Collection
Biotechnology and BioEngineering Abstracts
ProQuest Central Premium
ProQuest One Academic (New)
Publicly Available Content Database
ProQuest Health & Medical Research Collection
ProQuest One Academic Middle East (New)
ProQuest One Health & Nursing
ProQuest One Academic Eastern Edition (DO NOT USE)
ProQuest One Applied & Life Sciences
ProQuest One Academic
ProQuest One Academic UKI Edition
ProQuest Central China
MEDLINE - Academic
PubMed Central (Full Participant titles)
DOAJ Directory of Open Access Journals
DatabaseTitle CrossRef
MEDLINE
Medline Complete
MEDLINE with Full Text
PubMed
MEDLINE (Ovid)
Publicly Available Content Database
ProQuest Central Student
ProQuest Advanced Technologies & Aerospace Collection
ProQuest Central Essentials
ProQuest Computer Science Collection
Computer and Information Systems Abstracts
SciTech Premium Collection
ProQuest Central China
ProQuest One Applied & Life Sciences
Health Research Premium Collection
Natural Science Collection
Health & Medical Research Collection
Biological Science Collection
ProQuest Central (New)
ProQuest Medical Library (Alumni)
Advanced Technologies & Aerospace Collection
ProQuest Biological Science Collection
ProQuest One Academic Eastern Edition
Electronics & Communications Abstracts
ProQuest Hospital Collection
ProQuest Technology Collection
Health Research Premium Collection (Alumni)
Biological Science Database
ProQuest Hospital Collection (Alumni)
Biotechnology and BioEngineering Abstracts
ProQuest Health & Medical Complete
ProQuest One Academic UKI Edition
Solid State and Superconductivity Abstracts
Engineering Research Database
ProQuest One Academic
ProQuest One Academic (New)
Technology Collection
Technology Research Database
Computer and Information Systems Abstracts – Academic
ProQuest One Academic Middle East (New)
ProQuest Health & Medical Complete (Alumni)
ProQuest Central (Alumni Edition)
ProQuest One Community College
ProQuest One Health & Nursing
ProQuest Natural Science Collection
ProQuest Central
ProQuest Health & Medical Research Collection
Health and Medicine Complete (Alumni Edition)
ProQuest Central Korea
Advanced Technologies Database with Aerospace
ProQuest SciTech Collection
Computer and Information Systems Abstracts Professional
Advanced Technologies & Aerospace Database
ProQuest Medical Library
Biochemistry Abstracts 1
ProQuest Central (Alumni)
MEDLINE - Academic
DatabaseTitleList Publicly Available Content Database

MEDLINE
MEDLINE - Academic



Database_xml – sequence: 1
  dbid: DOA
  name: DOAJ Directory of Open Access Journals
  url: https://www.doaj.org/
  sourceTypes: Open Website
– sequence: 2
  dbid: NPM
  name: PubMed
  url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed
  sourceTypes: Index Database
– sequence: 3
  dbid: EIF
  name: MEDLINE
  url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search
  sourceTypes: Index Database
– sequence: 4
  dbid: 8FG
  name: ProQuest Technology Collection
  url: https://search.proquest.com/technologycollection1
  sourceTypes: Aggregation Database
DeliveryMethod fulltext_linktorsrc
Discipline Medicine
EISSN 1532-429X
EndPage 15
ExternalDocumentID oai_doaj_org_article_f4635bd0b8b54e90bd87172bf07f84b9
PMC8237445
A672269023
34176516
10_1186_s12968_021_00771_y
Genre Research Support, Non-U.S. Gov't
Journal Article
GrantInformation_xml – fundername: ;
– fundername: ;
  grantid: JP19K17510
GroupedDBID ---
.1-
.FO
0R~
29K
2VQ
2WC
36B
4.4
53G
5GY
5VS
7X7
88E
8FE
8FG
8FH
8FI
8FJ
AAFWJ
AALRI
AAWTL
AAXUO
AAYWO
AAYXX
ABDBF
ABUWG
ACGEJ
ACGFO
ACGFS
ACIWK
ACPRK
ACUHS
ACVFH
ADBBV
ADCNI
ADCVX
ADRAZ
ADUKV
ADVLN
ADXPE
AENEX
AEUPX
AFCTW
AFJKZ
AFKRA
AFPKN
AFPUW
AFRAH
AFRHN
AHBYD
AHMBA
AHSBF
AHYZX
AIGII
AITUG
AJUYK
AJWEG
AKBMS
AKRWK
AKYEP
ALIPV
ALMA_UNASSIGNED_HOLDINGS
AMKLP
AMRAJ
AMTXH
AOIJS
APXCP
ARAPS
AWYRJ
BAPOH
BAWUL
BBNVY
BCNDV
BENPR
BFQNJ
BGLVJ
BHPHI
BMC
BPHCQ
BVXVI
C6C
CAG
CCPQU
CITATION
COF
CS3
D-I
DIK
DU5
E3Z
EAP
EBC
EBD
EBS
EJD
EMB
EMK
EMOBN
EST
ESX
F5P
FDB
FRP
FYUFA
GROUPED_DOAJ
GX1
H13
HCIFZ
HMCUK
HYE
HZ~
IAO
IHR
IHW
INR
IPNFZ
KQ8
LK8
M1P
M41
M48
M7P
O5R
O5S
O9-
OK1
OVT
P2P
P62
P6G
PHGZM
PHGZT
PIMPY
PQQKQ
PROAC
PSQYO
RBZ
RIG
RNS
ROL
RPM
RSV
SMD
SOJ
SV3
TDBHL
TFW
TR2
TUS
UKHRP
Z5R
ZCN
-5E
-5G
-A0
-BR
3V.
ACRMQ
ADINQ
C24
CGR
CUY
CVF
EAD
ECM
EIF
INH
M~E
NPM
PMFND
7SC
7SP
7U5
7XB
8FD
8FK
AZQEC
DWQXO
FR3
GNUQQ
JQ2
K9.
L7M
L~C
L~D
M7Z
P64
PJZUB
PKEHL
PPXIY
PQEST
PQGLB
PQUKI
PRINS
7X8
5PM
PUEGO
ID FETCH-LOGICAL-c638t-5d9141dda7484459f0814b04da0d0ff209a342f23095e33feea512355cd979d73
IEDL.DBID M48
ISSN 1097-6647
1532-429X
IngestDate Wed Aug 27 01:19:29 EDT 2025
Thu Aug 21 18:31:20 EDT 2025
Fri Jul 11 16:48:54 EDT 2025
Fri Jul 25 19:07:12 EDT 2025
Tue Jun 17 21:36:14 EDT 2025
Tue Jun 10 20:37:50 EDT 2025
Thu May 22 21:21:50 EDT 2025
Wed Feb 19 02:08:56 EST 2025
Tue Jul 01 02:54:56 EDT 2025
Thu Apr 24 22:59:03 EDT 2025
IsDoiOpenAccess true
IsOpenAccess true
IsPeerReviewed true
IsScholarly true
Issue 1
Keywords Aortic stenosis
Four-dimensional flow cardiovascular magnetic resonance
Blood flow dynamics
Transcatheter aortic valve replacement
Language English
License Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
LinkModel DirectLink
MergedId FETCHMERGED-LOGICAL-c638t-5d9141dda7484459f0814b04da0d0ff209a342f23095e33feea512355cd979d73
Notes ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
ORCID 0000-0002-1043-0608
OpenAccessLink http://journals.scholarsportal.info/openUrl.xqy?doi=10.1186/s12968-021-00771-y
PMID 34176516
PQID 2552824703
PQPubID 55371
PageCount 15
ParticipantIDs doaj_primary_oai_doaj_org_article_f4635bd0b8b54e90bd87172bf07f84b9
pubmedcentral_primary_oai_pubmedcentral_nih_gov_8237445
proquest_miscellaneous_2545987126
proquest_journals_2552824703
gale_infotracmisc_A672269023
gale_infotracacademiconefile_A672269023
gale_healthsolutions_A672269023
pubmed_primary_34176516
crossref_primary_10_1186_s12968_021_00771_y
crossref_citationtrail_10_1186_s12968_021_00771_y
ProviderPackageCode CITATION
AAYXX
PublicationCentury 2000
PublicationDate 2021-06-28
PublicationDateYYYYMMDD 2021-06-28
PublicationDate_xml – month: 06
  year: 2021
  text: 2021-06-28
  day: 28
PublicationDecade 2020
PublicationPlace England
PublicationPlace_xml – name: England
– name: New York
– name: London
PublicationTitle Journal of cardiovascular magnetic resonance
PublicationTitleAlternate J Cardiovasc Magn Reson
PublicationYear 2021
Publisher BioMed Central Ltd
BioMed Central
Elsevier
Publisher_xml – name: BioMed Central Ltd
– name: BioMed Central
– name: Elsevier
References Tariq (10.1186/s12968-021-00771-y_bib43) 2013; 37
Popma (10.1186/s12968-021-00771-y_bib3) 2019; 380
Trauzeddel (10.1186/s12968-021-00771-y_bib15) 2016; 32
Rodríguez-Palomares (10.1186/s12968-021-00771-y_bib42) 2018; 20
Chirinos (10.1186/s12968-021-00771-y_bib7) 2013; 7
Zoghbi (10.1186/s12968-021-00771-y_bib21) 2009; 22
von Knobelsdorff-Brenkenhoff (10.1186/s12968-021-00771-y_bib13) 2016; 9
Segadal (10.1186/s12968-021-00771-y_bib26) 1987; 76
Rich (10.1186/s12968-021-00771-y_bib44) 2019; 81
Potters (10.1186/s12968-021-00771-y_bib24) 2015; 41
Morbiducci (10.1186/s12968-021-00771-y_bib27) 2011; 10
Barker (10.1186/s12968-021-00771-y_bib18) 2014; 72
Komoriyama (10.1186/s12968-021-00771-y_bib17) 2020; 21
Kadbi (10.1186/s12968-021-00771-y_bib46) 2015; 73
Genereux (10.1186/s12968-021-00771-y_bib6) 2013; 61
Kilner (10.1186/s12968-021-00771-y_bib12) 1993; 88
Chen (10.1186/s12968-021-00771-y_bib8) 1998; 32
Garcia (10.1186/s12968-021-00771-y_bib32) 2019; 12
Nishimura (10.1186/s12968-021-00771-y_bib1) 2017; 135
Miyazaki (10.1186/s12968-021-00771-y_bib22) 2017; 32
Takei (10.1186/s12968-021-00771-y_bib23) 2019; 28
Stonebridge (10.1186/s12968-021-00771-y_bib28) 2004; 23
Farag (10.1186/s12968-021-00771-y_bib35) 2018; 48
Stalder (10.1186/s12968-021-00771-y_bib11) 2008; 60
Ma (10.1186/s12968-021-00771-y_bib45) 2019; 81
Redheuil (10.1186/s12968-021-00771-y_bib9) 2019; 317
Dyverfeldt (10.1186/s12968-021-00771-y_bib40) 2015; 17
Farag (10.1186/s12968-021-00771-y_bib16) 2019; 29
Nishimura (10.1186/s12968-021-00771-y_bib19) 2014; 148
Mack (10.1186/s12968-021-00771-y_bib2) 2019; 380
Barone-Rochette (10.1186/s12968-021-00771-y_bib5) 2014; 64
Yoganathan (10.1186/s12968-021-00771-y_bib33) 2004; 6
Cibis (10.1186/s12968-021-00771-y_bib39) 2016; 11
Ha (10.1186/s12968-021-00771-y_bib30) 2016; 6
von Knobelsdorff-Brenkenhoff (10.1186/s12968-021-00771-y_bib14) 2014; 170
Markl (10.1186/s12968-021-00771-y_bib29) 2004; 28
Hope (10.1186/s12968-021-00771-y_bib34) 2011; 4
Stugaard (10.1186/s12968-021-00771-y_bib25) 2015; 16
Tribouilloy (10.1186/s12968-021-00771-y_bib20) 2019; 8
Herrmann (10.1186/s12968-021-00771-y_bib36) 2018; 72
Frydrychowicz (10.1186/s12968-021-00771-y_bib31) 2012; 22
Hatani (10.1186/s12968-021-00771-y_bib4) 2016; 68
Bahlmann (10.1186/s12968-021-00771-y_bib38) 2013; 127
Itatani (10.1186/s12968-021-00771-y_bib10) 2017; 65
Hahn (10.1186/s12968-021-00771-y_bib37) 2013; 61
Petersson (10.1186/s12968-021-00771-y_bib41) 2012; 36
References_xml – volume: 21
  start-page: 21
  year: 2020
  ident: 10.1186/s12968-021-00771-y_bib17
  article-title: Four-dimensional flow magnetic resonance imaging visualizes significant changes in flow pattern and wall shear stress in the ascending aorta after transcatheter aortic valve implantation in a patient with severe aortic stenosis
  publication-title: Eur Heart J Cardiovasc Imaging
– volume: 170
  start-page: 426
  year: 2014
  ident: 10.1186/s12968-021-00771-y_bib14
  article-title: Blood flow characteristics in the ascending aorta after aortic valve replacement–a pilot study using 4D-flow MRI
  publication-title: Int J Cardiol
  doi: 10.1016/j.ijcard.2013.11.034
– volume: 28
  start-page: 413
  year: 2019
  ident: 10.1186/s12968-021-00771-y_bib23
  article-title: Four-dimensional flow magnetic resonance imaging analysis before and after thoracic endovascular aortic repair of chronic type B aortic dissection
  publication-title: Interact Cardiovasc Thorac Surg
  doi: 10.1093/icvts/ivy271
– volume: 61
  start-page: 1125
  year: 2013
  ident: 10.1186/s12968-021-00771-y_bib6
  article-title: Paravalvular leak after transcatheter aortic valve replacement: the new Achilles' heel? A comprehensive review of the literature
  publication-title: J Am Coll Cardiol
  doi: 10.1016/j.jacc.2012.08.1039
– volume: 72
  start-page: 620
  year: 2014
  ident: 10.1186/s12968-021-00771-y_bib18
  article-title: Viscous energy loss in the presence of abnormal aortic flow
  publication-title: Magn Reson Med
  doi: 10.1002/mrm.24962
– volume: 28
  start-page: 459
  year: 2004
  ident: 10.1186/s12968-021-00771-y_bib29
  article-title: Time-resolved 3-dimensional velocity mapping in the thoracic aorta: visualization of 3-directional blood flow patterns in healthy volunteers and patients
  publication-title: J Comput Assist Tomogr
  doi: 10.1097/00004728-200407000-00005
– volume: 9
  start-page: e004038
  year: 2016
  ident: 10.1186/s12968-021-00771-y_bib13
  article-title: Evaluation of aortic blood flow and wall shear stress in aortic stenosis and its association with left ventricular remodeling
  publication-title: Circ Cardiovasc Imaging.
  doi: 10.1161/CIRCIMAGING.115.004038
– volume: 81
  start-page: 3675
  year: 2019
  ident: 10.1186/s12968-021-00771-y_bib45
  article-title: Aortic 4D flow MRI in 2 minutes using compressed sensing, respiratory controlled adaptive k-space reordering, and inline reconstruction
  publication-title: Magn Reson Med
  doi: 10.1002/mrm.27684
– volume: 65
  start-page: 611
  year: 2017
  ident: 10.1186/s12968-021-00771-y_bib10
  article-title: New imaging tools in cardiovascular medicine: computational fluid dynamics and 4D flow MRI
  publication-title: Gen Thorac Cardiovasc Surg
  doi: 10.1007/s11748-017-0834-5
– volume: 135
  start-page: e1159
  year: 2017
  ident: 10.1186/s12968-021-00771-y_bib1
  article-title: 2017 AHA/ACC Focused Update of the 2014 AHA/ACC Guideline for the Management of Patients With Valvular Heart Disease: A Report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines
  publication-title: Circulation
  doi: 10.1161/CIR.0000000000000503
– volume: 20
  start-page: 28
  year: 2018
  ident: 10.1186/s12968-021-00771-y_bib42
  article-title: Aortic flow patterns and wall shear stress maps by 4D-flow cardiovascular magnetic resonance in the assessment of aortic dilatation in bicuspid aortic valve disease
  publication-title: J Cardiovasc Magn Reson
  doi: 10.1186/s12968-018-0451-1
– volume: 72
  start-page: 2701
  year: 2018
  ident: 10.1186/s12968-021-00771-y_bib36
  article-title: Prosthesis-patient mismatch in patients undergoing transcatheter aortic valve replacement: from the STS/ACC TVT Registry
  publication-title: J Am Coll Cardiol
  doi: 10.1016/j.jacc.2018.09.001
– volume: 16
  start-page: 723
  year: 2015
  ident: 10.1186/s12968-021-00771-y_bib25
  article-title: Energy loss in the left ventricle obtained by vector flow mapping as a new quantitative measure of severity of aortic regurgitation: a combined experimental and clinical study
  publication-title: Eur Heart J Cardiovasc Imaging
  doi: 10.1093/ehjci/jev035
– volume: 7
  start-page: 2
  year: 2013
  ident: 10.1186/s12968-021-00771-y_bib7
  article-title: Ventricular-arterial coupling: invasive and non-invasive assessment
  publication-title: Artery Res
  doi: 10.1016/j.artres.2012.12.002
– volume: 380
  start-page: 1706
  year: 2019
  ident: 10.1186/s12968-021-00771-y_bib3
  article-title: Transcatheter aortic-valve replacement with a self-expanding valve in low-risk patients
  publication-title: N Engl J Med
  doi: 10.1056/NEJMoa1816885
– volume: 60
  start-page: 1218
  year: 2008
  ident: 10.1186/s12968-021-00771-y_bib11
  article-title: Quantitative 2D and 3D phase contrast MRI: optimized analysis of blood flow and vessel wall parameters
  publication-title: Magn Reson Med
  doi: 10.1002/mrm.21778
– volume: 32
  start-page: 1032
  year: 2017
  ident: 10.1186/s12968-021-00771-y_bib22
  article-title: Validation of numerical simulation methods in aortic arch using 4D Flow MRI
  publication-title: Heart Vessels
  doi: 10.1007/s00380-017-0979-2
– volume: 36
  start-page: 128
  year: 2012
  ident: 10.1186/s12968-021-00771-y_bib41
  article-title: Assessment of the accuracy of MRI wall shear stress estimation using numerical simulations
  publication-title: J Magn Reson Imaging
  doi: 10.1002/jmri.23610
– volume: 64
  start-page: 144
  year: 2014
  ident: 10.1186/s12968-021-00771-y_bib5
  article-title: Prognostic significance of LGE by CMR in aortic stenosis patients undergoing valve replacement
  publication-title: J Am Coll Cardiol.
  doi: 10.1016/j.jacc.2014.02.612
– volume: 6
  start-page: 331
  year: 2004
  ident: 10.1186/s12968-021-00771-y_bib33
  article-title: Fluid mechanics of heart valves
  publication-title: Annu Rev Biomed Eng
  doi: 10.1146/annurev.bioeng.6.040803.140111
– volume: 380
  start-page: 1695
  year: 2019
  ident: 10.1186/s12968-021-00771-y_bib2
  article-title: Transcatheter aortic-valve replacement with a balloon-expandable valve in low-risk patients
  publication-title: N Engl J Med
  doi: 10.1056/NEJMoa1814052
– volume: 32
  start-page: 461
  year: 2016
  ident: 10.1186/s12968-021-00771-y_bib15
  article-title: Blood flow characteristics in the ascending aorta after TAVI compared to surgical aortic valve replacement
  publication-title: Int J Cardiovasc Imaging
  doi: 10.1007/s10554-015-0792-x
– volume: 8
  start-page: 11724
  year: 2019
  ident: 10.1186/s12968-021-00771-y_bib20
  article-title: How should very severe aortic stenosis be defined in asymptomatic individuals?
  publication-title: J Am Heart Assoc.
  doi: 10.1161/JAHA.118.011724
– volume: 32
  start-page: 1221
  year: 1998
  ident: 10.1186/s12968-021-00771-y_bib8
  article-title: Coupled systolic-ventricular and vascular stiffening with age: implications for pressure regulation and cardiac reserve in the elderly
  publication-title: J Am Coll Cardiol
  doi: 10.1016/S0735-1097(98)00374-X
– volume: 6
  start-page: 32316
  year: 2016
  ident: 10.1186/s12968-021-00771-y_bib30
  article-title: The influence of the aortic valve angle on the hemodynamic features of the thoracic aorta
  publication-title: Sci Rep
  doi: 10.1038/srep32316
– volume: 68
  start-page: 241
  year: 2016
  ident: 10.1186/s12968-021-00771-y_bib4
  article-title: Associations of residual left ventricular and left atrial remodeling with clinical outcomes in patients after aortic valve replacement for severe aortic stenosis
  publication-title: J Cardiol
  doi: 10.1016/j.jjcc.2015.09.017
– volume: 29
  start-page: 1444
  year: 2019
  ident: 10.1186/s12968-021-00771-y_bib16
  article-title: Transcatheter aortic valve replacement alters ascending aortic blood flow and wall shear stress patterns: a 4D flow MRI comparison with age-matched, elderly controls
  publication-title: Eur Radiol
  doi: 10.1007/s00330-018-5672-z
– volume: 73
  start-page: 939
  year: 2015
  ident: 10.1186/s12968-021-00771-y_bib46
  article-title: 4D UTE flow: a phase-contrast MRI technique for assessment and visualization of stenotic flows
  publication-title: Magn Reson Med
  doi: 10.1002/mrm.25188
– volume: 88
  start-page: 2235
  year: 1993
  ident: 10.1186/s12968-021-00771-y_bib12
  article-title: Helical and retrograde secondary flow patterns in the aortic arch studied by three-directional magnetic resonance velocity mapping
  publication-title: Circulation
  doi: 10.1161/01.CIR.88.5.2235
– volume: 22
  start-page: 975
  year: 2009
  ident: 10.1186/s12968-021-00771-y_bib21
  publication-title: J Am Soc Echocardiogr
  doi: 10.1016/j.echo.2009.07.013
– volume: 41
  start-page: 505
  year: 2015
  ident: 10.1186/s12968-021-00771-y_bib24
  article-title: Volumetric arterial wall shear stress calculation based on cine phase contrast MRI
  publication-title: J Magn Reson Imaging
  doi: 10.1002/jmri.24560
– volume: 23
  start-page: 276
  year: 2004
  ident: 10.1186/s12968-021-00771-y_bib28
  article-title: Non spiral and spiral (helical) flow patterns in stenosis. In vitro observations using spin and gradient echo magnetic resonance imaging (MRI) and computational fluid dynamic modeling
  publication-title: Int Angiol.
– volume: 17
  start-page: 72
  year: 2015
  ident: 10.1186/s12968-021-00771-y_bib40
  article-title: 4D flow cardiovascular magnetic resonance consensus statement
  publication-title: J Cardiovasc Magn Reson
  doi: 10.1186/s12968-015-0174-5
– volume: 10
  start-page: 339
  year: 2011
  ident: 10.1186/s12968-021-00771-y_bib27
  article-title: Mechanistic insight into the physiological relevance of helical blood flow in the human aorta: an in vivo study
  publication-title: Biomech Model Mechanobiol
  doi: 10.1007/s10237-010-0238-2
– volume: 148
  start-page: e1
  year: 2014
  ident: 10.1186/s12968-021-00771-y_bib19
  article-title: 2014 AHA/ACC guideline for the management of patients with valvular heart disease: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines
  publication-title: J Thorac Cardiovasc Surg
  doi: 10.1016/j.jtcvs.2014.05.014
– volume: 127
  start-page: 1149
  year: 2013
  ident: 10.1186/s12968-021-00771-y_bib38
  article-title: Prognostic value of energy loss index in asymptomatic aortic stenosis
  publication-title: Circulation
  doi: 10.1161/CIRCULATIONAHA.112.078857
– volume: 76
  start-page: 90
  year: 1987
  ident: 10.1186/s12968-021-00771-y_bib26
  article-title: Blood velocity distribution in the human ascending aorta
  publication-title: Circulation
  doi: 10.1161/01.CIR.76.1.90
– volume: 22
  start-page: 1122
  year: 2012
  ident: 10.1186/s12968-021-00771-y_bib31
  article-title: Interdependencies of aortic arch secondary flow patterns, geometry, and age analysed by 4-dimensional phase contrast magnetic resonance imaging at 3 Tesla
  publication-title: Eur Radiol
  doi: 10.1007/s00330-011-2353-6
– volume: 81
  start-page: 811
  year: 2019
  ident: 10.1186/s12968-021-00771-y_bib44
  article-title: A Bayesian approach for 4D flow imaging of aortic valve in a single breath-hold
  publication-title: Magn Reson Med
  doi: 10.1002/mrm.27386
– volume: 48
  start-page: 522
  year: 2018
  ident: 10.1186/s12968-021-00771-y_bib35
  article-title: Aortic valve stenosis and aortic diameters determine the extent of increased wall shear stress in bicuspid aortic valve disease
  publication-title: J Magn Reson Imaging
  doi: 10.1002/jmri.25956
– volume: 317
  start-page: H300
  year: 2019
  ident: 10.1186/s12968-021-00771-y_bib9
  article-title: Left ventricular and proximal aorta coupling in magnetic resonance imaging: aging together?
  publication-title: Am J Physiol Heart Circ Physiol
  doi: 10.1152/ajpheart.00694.2018
– volume: 4
  start-page: 781
  year: 2011
  ident: 10.1186/s12968-021-00771-y_bib34
  article-title: 4D flow CMR in assessment of valve-related ascending aortic disease
  publication-title: JACC Cardiovasc Imaging
  doi: 10.1016/j.jcmg.2011.05.004
– volume: 37
  start-page: 1419
  year: 2013
  ident: 10.1186/s12968-021-00771-y_bib43
  article-title: Venous and arterial flow quantification are equally accurate and precise with parallel imaging compressed sensing 4D phase contrast MRI
  publication-title: J Magn Reson Imaging
  doi: 10.1002/jmri.23936
– volume: 11
  start-page: e0163316
  year: 2016
  ident: 10.1186/s12968-021-00771-y_bib39
  article-title: The effect of spatial and temporal resolution of cine phase contrast MRI on wall shear stress and oscillatory shear index assessment
  publication-title: PLoS ONE
  doi: 10.1371/journal.pone.0163316
– volume: 12
  start-page: 252
  year: 2019
  ident: 10.1186/s12968-021-00771-y_bib32
  article-title: The role of imaging of flow patterns by 4D flow MRI in aortic stenosis
  publication-title: JACC Cardiovasc Imaging
  doi: 10.1016/j.jcmg.2018.10.034
– volume: 61
  start-page: 2514
  year: 2013
  ident: 10.1186/s12968-021-00771-y_bib37
  article-title: Comparison of transcatheter and surgical aortic valve replacement in severe aortic stenosis: a longitudinal study of echocardiography parameters in cohort A of the PARTNER trial (placement of aortic transcatheter valves)
  publication-title: J Am Coll Cardiol
  doi: 10.1016/j.jacc.2013.02.087
SSID ssj0019707
Score 2.3856525
Snippet Pre- and post-procedural hemodynamic changes which could affect adverse outcomes in aortic stenosis (AS) patients who undergo transcatheter aortic valve...
Background Pre- and post-procedural hemodynamic changes which could affect adverse outcomes in aortic stenosis (AS) patients who undergo transcatheter aortic...
Abstract Background Pre- and post-procedural hemodynamic changes which could affect adverse outcomes in aortic stenosis (AS) patients who undergo transcatheter...
SourceID doaj
pubmedcentral
proquest
gale
pubmed
crossref
SourceType Open Website
Open Access Repository
Aggregation Database
Index Database
Enrichment Source
StartPage 81
SubjectTerms Aorta
Aortic stenosis
Aortic valve
Aortic Valve - diagnostic imaging
Aortic Valve - surgery
Aortic valve stenosis
Aortic Valve Stenosis - diagnostic imaging
Aortic Valve Stenosis - surgery
Blood flow
Blood flow dynamics
Care and treatment
Coronary vessels
Energy dissipation
Flow distribution
Flow velocity
Four-dimensional flow cardiovascular magnetic resonance
Heart
Heart valves
Helical flow
Hemodynamics
Humans
Magnetic resonance
Magnetic Resonance Spectroscopy
Male
Orifices
Patients
Predictive Value of Tests
Severity of Illness Index
Software
Stenosis
Stroke Volume
Transcatheter aortic valve replacement
Transcatheter Aortic Valve Replacement - adverse effects
Treatment Outcome
Ventricle
Ventricular Function, Left
Wall shear stresses
SummonAdditionalLinks – databaseName: DOAJ Directory of Open Access Journals
  dbid: DOA
  link: http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwrV1Lb9QwELZQD4gLojyXFjASEgdk1Ulsxzm2iKpCKicq9Wb5CSuVpCJbUH8S_5IZxxtthAQXjonHeXjGnm-Smc-EvAGXBp7HclZ1UjKRkmZW1I4JF60DfFD5Cguczz-pswvx8VJe7mz1hTlhEz3wNHBHSYBLdIE77aSIHXcBIH5bu8TbpIXLpXvg87bBVPl_0LW83ZbIaHU0gldTmmE6AvLXVOx24YYyW_-fa_KOU1omTO54oNMH5H6BjvR4euR9cif2D8nd8_Jz_BH5dYJJ6DRdDT9pmDaaHyl-Z6UJurKAPP4TB8ck4xepqPSb_dJjRSOFAHxAGo5I1z0tvKvlQnbAm1OwjH4Y1yN1ETBvpLYPNG82Tjfo-jIVLB4VcTDmHxEum_O_8GvkY3Jx-uHz-zNWdmJgHubnhsnQVaIKwSLzqJBdAiAhHBfB8sBTAgXYRtQJwplOxqZJMVqJRbjSh67tQts8IXv90MdnhKq6ctqHpJMG8KKl9cpXteXeA5YIvFmRaqsY4wtNOe6WcWVyuKKVmZRpQJkmK9Pcrsi7uc_1RNLxV-kT1PcsiQTb-QSYnSlmZ_5ldivyCq3FTNWq8zJhjlULgLYDJLQib7MELhTwAt6WegcYBqTcWkgeLiRhgvtl89YiTVlgRgORIATLosUBez03Y09MmuvjcIMyoCp47FqtyNPJgOeXBvDSKllBS7sw7cWoLFv69ddMP470RmAEz__HMB6Qe3WelYrV-pDsbb7fxBeA8jbuZZ7QvwFcQVIN
  priority: 102
  providerName: Directory of Open Access Journals
– databaseName: Health & Medical Collection
  dbid: 7X7
  link: http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwfV1Lb9QwELagSIgL4k2ggJGQOCCrediOc0ItoqqQyolKe7P8LCuVpDRbUH8S_5IZxxsaIfW48TibZGY8M_bMN4S8A5MGlseUrOqEYDxGxQyvLeM2GAv-QeUqLHA-_iqPTviXlVjlDbcxp1Vu18S0UPvB4R75Hri-EB1wENCP5z8Zdo3C09XcQuM2uYPQZZjS1a7mgKvq2lQujYesTErebotmlNwbwc5JxTBBARFtKna1MEwJv___VfqamVqmUF6zSYcPyP3sTNL9ifsPya3QPyJ3j_Nx-WPy5wDT0mk8G35TP7WeHynuvNIIU5lHZP8JlWOicYvkVPrDnPZY40ghJB8QmCPQdU8zEmu-kRnwzynISj-M65HaAF5woKb3NLUfpxs0hgkcFn9lchDvXwFumzLCcH_yCTk5_Pzt0xHLvRmYA43dMOG7ilfeG8Qi5aKL4FpwW3JvSl_GWJedaXgdIcDpRGiaGIIRWJYrnO_azrfNU7LTD314TqisK6ucjyoqcGeUME66qjalc-Bd-LIpSLVljHYZuBz7Z5zpFMAoqSdmamCmTszUVwX5MM85n2A7bqQ-QH7PlAi5nS4MF6c6a7COHHwz60urrOChK62HWLOtbSzbqLjtCvIGpUVP9avzwqH3ZQsubge-UUHeJwpcOuAFnMkVEPAZEIRrQbm7oASVd8vhrUTqvOSM-p-CFOTtPIwzMY2uD8Ml0gCr4LFrWZBnkwDPLw3uTCtFBSPtQrQXX2U50q-_J0ByBDwCIXhx82O9JPfqpG-S1WqX7GwuLsMr8Og29nVS27-DpktA
  priority: 102
  providerName: ProQuest
Title Blood flow dynamics with four-dimensional flow cardiovascular magnetic resonance in patients with aortic stenosis before and after transcatheter aortic valve replacement
URI https://www.ncbi.nlm.nih.gov/pubmed/34176516
https://www.proquest.com/docview/2552824703
https://www.proquest.com/docview/2545987126
https://pubmed.ncbi.nlm.nih.gov/PMC8237445
https://doaj.org/article/f4635bd0b8b54e90bd87172bf07f84b9
Volume 23
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV3dixMxEA_3Ace9iN-unjWC4INEd7fZJPsgcpWrh9BDxELflmSTnIW6q21P7Z_kf-lMdrd28fDBl0KbSbabmcnMJJnfEPIMTBpYHh2zJM8yxr1XTPPUMG6cNuAfJGWCCc6TC3E-5e9n2WyPdOWO2glcXRvaYT2p6XLx8ue3zRtQ-NdB4ZV4tQKbJRTDywaITpOwzT45BMskUVEn_M-pQi5D-jQeujIhuOySaK4d45gcwQovRYal0HdsVoD2_3sB37Fg_duVO-ZqfJPcaP1MetoIxi2y56rb5GjSnqTfIb9GeGOd-kX9g9qmKv2K4qYs9dCVWQT9bwA7Gpqyd2-VftGXFaY_UojWa8TscHRe0RaktR1I1_hwCmJU1av5ihoHDrKjurI0VCana7STATcWv7XkIPnfHQwbLovh1uVdMh2ffXp7ztqyDawEZV6zzOYJT6zVCFPKs9yD18FNzK2Obex9Gud6yFMPsU-eueHQO6czzNjNSpvL3MrhPXJQ1ZV7QKhIE6NK65VX4OmoTJeiTFIdlyWw18bDiCQdY4qyxTTH0hqLIsQ2ShQNXwvgaxH4Wmwi8mLb52uD6PFP6hHye0uJaNzhh3p5WbTKXXgObpuxsVEm4y6PjYUwVKbGx9IrbvKIPEFpKZrU1u2aUpwKCd5vDm5TRJ4HCpRzeIFSt8kRMA2Iz9WjPOlRwmpQ9ps7iSw6ZSogbITImkucsKfbZuyJN-wqV18hDbAK_nYqInK_EeDtS3d6EBHZE-3erPRbqvnngFWOWEggBA__u-cjcpwGrRQsVSfkYL28co_BD1ybAdmXMwmfavxuQA5HZxcfPg7CnsogqP1vBTdgZw
linkProvider Scholars Portal
linkToHtml http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwtV1Lb9QwELZKkYAL4lkChRoJxAFZTbKOkxwQaoFqS7s9tdLejJ9lpZKUzZZqfxIXfiMzTjY0Quqtx43H2SQznvnGngchb8CkgeVRMUvKLGPc-4IpnmrGtVMa8EFiEkxwnhyJ8Qn_Os2ma-TPKhcGwypXOjEoalsb3CPfBugL3gEHAf14_pNh1yg8XV210GjF4sAtL8Flaz7sfwb-vk3TvS_Hn8as6yrADMjagmW2THhircIqmjwrPRhFrmNuVWxj79O4VCOeeoDmZeZGI--cyjChNDO2zEubj-C-t8htMLwxrqh82jt4SZmH9Gw81GVC8HyVpFOI7QbsqigYBkRgBZ2ELQeGMPQL-N8qXDGLw5DNKzZw7wG534FXutNK20Oy5qpH5M6kO55_TH7vYhg89Wf1JbVtq_uG4k4v9TCVWewk0FYBaWnMIBiW_lCnFeZU0rlDBwHEkc4q2lV-7W6kavxzCrJZ1c2sodoB6nZUVZaGdud0gcY3FKPFXx05LKdfDm4bItBwP_QJObkRrj0l61VduWeEijTRhbG-8AXApyJTRpgkVbExgGZsPIpIsmKMNF2hdOzXcSaDw1QI2TJTAjNlYKZcRuR9P-e8LRNyLfUu8runxBLf4UI9P5WdxpCeAxbUNtaFzrgrY23Bt81T7ePcF1yXEdlCaZFtvmyvqOSOyAFSl4DFIvIuUKCqghcwqsu4gM-ARb8GlJsDSlAxZji8kkjZqbhG_luQEXndD-NMDNurXH2BNMAqeOxURGSjFeD-pQE-5SJLYCQfiPbgqwxHqtn3UAAdCyyBEDy__rG2yN3x8eRQHu4fHbwg99Kw9gRLi02yvphfuJeAJhf6VVjClHy7aZ3xF7SbhsM
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Blood+flow+dynamics+with+four-dimensional+flow+cardiovascular+magnetic+resonance+in+patients+with+aortic+stenosis+before+and+after+transcatheter+aortic+valve+replacement&rft.jtitle=Journal+of+cardiovascular+magnetic+resonance&rft.au=Komoriyama%2C+Hirokazu&rft.au=Kamiya%2C+Kiwamu&rft.au=Nagai%2C+Toshiyuki&rft.au=Oyama-Manabe%2C+Noriko&rft.date=2021-06-28&rft.pub=BioMed+Central&rft.issn=1097-6647&rft.eissn=1532-429X&rft.volume=23&rft_id=info:doi/10.1186%2Fs12968-021-00771-y&rft_id=info%3Apmid%2F34176516&rft.externalDocID=PMC8237445
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1097-6647&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1097-6647&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1097-6647&client=summon