A new method for assessing the accuracy of full arch impressions in patients

To evaluate a new method of measuring the real deviation (trueness) of full arch impressions intraorally and to investigate the trueness of digital full arch impressions in comparison to a conventional impression procedure in clinical use. Four metal spheres were fixed with composite using a metal a...

Full description

Saved in:
Bibliographic Details
Published inJournal of dentistry Vol. 55; pp. 68 - 74
Main Authors Kuhr, F., Schmidt, A., Rehmann, P., Wöstmann, B.
Format Journal Article
LanguageEnglish
Published England Elsevier Ltd 01.12.2016
Elsevier Limited
Subjects
Online AccessGet full text

Cover

Loading…
Abstract To evaluate a new method of measuring the real deviation (trueness) of full arch impressions intraorally and to investigate the trueness of digital full arch impressions in comparison to a conventional impression procedure in clinical use. Four metal spheres were fixed with composite using a metal application aid to the lower teeth of 50 test subjects as reference structures. One conventional impression (Impregum Penta Soft) with subsequent type-IV gypsum model casting (CI) and three different digital impressions were performed in the lower jaw of each test person with the following intraoral scanners: Sirona CEREC Omnicam (OC), 3M True Definition (TD), Heraeus Cara TRIOS (cT). The digital and conventional (gypsum) models were analyzed relative to the spheres. Linear distance and angle measurements between the spheres, as well as digital superimpositions of the spheres with the reference data set were executed. With regard to the distance measurements, CI showed the smallest deviations followed by intraoral scanners TD, cT and OC. A digital superimposition procedure yielded the same order for the outcomes: CI (15±4μm), TD (23±9μm), cT (37±14μm), OC (214±38μm). Angle measurements revealed the smallest deviation for TD (0.06°±0,07°) followed by CI (0.07°±0.07°), cT (0.13°±0.15°) and OC (0.28°±0.21°). The new measuring method is suitable for measuring the dimensional accuracy of full arch impressions intraorally. CI is still significantly more accurate than full arch scans with intraoral scanners in clinical use. Conventional full arch impressions with polyether impression materials are still more accurate than full arch digital impressions. Digital impression systems using powder application and active wavefront sampling technology achieve the most accurate results in comparison to other intraoral scanning systems (DRKS-ID: DRKS00009360, German Clinical Trials Register).
AbstractList To evaluate a new method of measuring the real deviation (trueness) of full arch impressions intraorally and to investigate the trueness of digital full arch impressions in comparison to a conventional impression procedure in clinical use.OBJECTIVETo evaluate a new method of measuring the real deviation (trueness) of full arch impressions intraorally and to investigate the trueness of digital full arch impressions in comparison to a conventional impression procedure in clinical use.Four metal spheres were fixed with composite using a metal application aid to the lower teeth of 50 test subjects as reference structures. One conventional impression (Impregum Penta Soft) with subsequent type-IV gypsum model casting (CI) and three different digital impressions were performed in the lower jaw of each test person with the following intraoral scanners: Sirona CEREC Omnicam (OC), 3M True Definition (TD), Heraeus Cara TRIOS (cT). The digital and conventional (gypsum) models were analyzed relative to the spheres. Linear distance and angle measurements between the spheres, as well as digital superimpositions of the spheres with the reference data set were executed.METHODSFour metal spheres were fixed with composite using a metal application aid to the lower teeth of 50 test subjects as reference structures. One conventional impression (Impregum Penta Soft) with subsequent type-IV gypsum model casting (CI) and three different digital impressions were performed in the lower jaw of each test person with the following intraoral scanners: Sirona CEREC Omnicam (OC), 3M True Definition (TD), Heraeus Cara TRIOS (cT). The digital and conventional (gypsum) models were analyzed relative to the spheres. Linear distance and angle measurements between the spheres, as well as digital superimpositions of the spheres with the reference data set were executed.With regard to the distance measurements, CI showed the smallest deviations followed by intraoral scanners TD, cT and OC. A digital superimposition procedure yielded the same order for the outcomes: CI (15±4μm), TD (23±9μm), cT (37±14μm), OC (214±38μm). Angle measurements revealed the smallest deviation for TD (0.06°±0,07°) followed by CI (0.07°±0.07°), cT (0.13°±0.15°) and OC (0.28°±0.21°).RESULTSWith regard to the distance measurements, CI showed the smallest deviations followed by intraoral scanners TD, cT and OC. A digital superimposition procedure yielded the same order for the outcomes: CI (15±4μm), TD (23±9μm), cT (37±14μm), OC (214±38μm). Angle measurements revealed the smallest deviation for TD (0.06°±0,07°) followed by CI (0.07°±0.07°), cT (0.13°±0.15°) and OC (0.28°±0.21°).The new measuring method is suitable for measuring the dimensional accuracy of full arch impressions intraorally. CI is still significantly more accurate than full arch scans with intraoral scanners in clinical use.CONCLUSIONThe new measuring method is suitable for measuring the dimensional accuracy of full arch impressions intraorally. CI is still significantly more accurate than full arch scans with intraoral scanners in clinical use.Conventional full arch impressions with polyether impression materials are still more accurate than full arch digital impressions. Digital impression systems using powder application and active wavefront sampling technology achieve the most accurate results in comparison to other intraoral scanning systems (DRKS-ID: DRKS00009360, German Clinical Trials Register).CLINICAL SIGNIFICANCEConventional full arch impressions with polyether impression materials are still more accurate than full arch digital impressions. Digital impression systems using powder application and active wavefront sampling technology achieve the most accurate results in comparison to other intraoral scanning systems (DRKS-ID: DRKS00009360, German Clinical Trials Register).
Objective To evaluate a new method of measuring the real deviation (trueness) of full arch impressions intraorally and to investigate the trueness of digital full arch impressions in comparison to a conventional impression procedure in clinical use. Methods Four metal spheres were fixed with composite using a metal application aid to the lower teeth of 50 test subjects as reference structures. One conventional impression (Impregum Penta Soft) with subsequent type-IV gypsum model casting (CI) and three different digital impressions were performed in the lower jaw of each test person with the following intraoral scanners: Sirona CEREC Omnicam (OC), 3M True Definition (TD), Heraeus Cara TRIOS (cT). The digital and conventional (gypsum) models were analyzed relative to the spheres. Linear distance and angle measurements between the spheres, as well as digital superimpositions of the spheres with the reference data set were executed. Results With regard to the distance measurements, CI showed the smallest deviations followed by intraoral scanners TD, cT and OC. A digital superimposition procedure yielded the same order for the outcomes: CI (15±4μm), TD (23±9μm), cT (37±14μm), OC (214±38μm). Angle measurements revealed the smallest deviation for TD (0.06°±0,07°) followed by CI (0.07°±0.07°), cT (0.13°±0.15°) and OC (0.28°±0.21°). Conclusion The new measuring method is suitable for measuring the dimensional accuracy of full arch impressions intraorally. CI is still significantly more accurate than full arch scans with intraoral scanners in clinical use. Clinical significance Conventional full arch impressions with polyether impression materials are still more accurate than full arch digital impressions. Digital impression systems using powder application and active wavefront sampling technology achieve the most accurate results in comparison to other intraoral scanning systems (DRKS-ID: DRKS00009360, German Clinical Trials Register).
To evaluate a new method of measuring the real deviation (trueness) of full arch impressions intraorally and to investigate the trueness of digital full arch impressions in comparison to a conventional impression procedure in clinical use. Four metal spheres were fixed with composite using a metal application aid to the lower teeth of 50 test subjects as reference structures. One conventional impression (Impregum Penta Soft) with subsequent type-IV gypsum model casting (CI) and three different digital impressions were performed in the lower jaw of each test person with the following intraoral scanners: Sirona CEREC Omnicam (OC), 3M True Definition (TD), Heraeus Cara TRIOS (cT). The digital and conventional (gypsum) models were analyzed relative to the spheres. Linear distance and angle measurements between the spheres, as well as digital superimpositions of the spheres with the reference data set were executed. With regard to the distance measurements, CI showed the smallest deviations followed by intraoral scanners TD, cT and OC. A digital superimposition procedure yielded the same order for the outcomes: CI (15±4μm), TD (23±9μm), cT (37±14μm), OC (214±38μm). Angle measurements revealed the smallest deviation for TD (0.06°±0,07°) followed by CI (0.07°±0.07°), cT (0.13°±0.15°) and OC (0.28°±0.21°). The new measuring method is suitable for measuring the dimensional accuracy of full arch impressions intraorally. CI is still significantly more accurate than full arch scans with intraoral scanners in clinical use. Conventional full arch impressions with polyether impression materials are still more accurate than full arch digital impressions. Digital impression systems using powder application and active wavefront sampling technology achieve the most accurate results in comparison to other intraoral scanning systems (DRKS-ID: DRKS00009360, German Clinical Trials Register).
Objective To evaluate a new method of measuring the real deviation (trueness) of full arch impressions intraorally and to investigate the trueness of digital full arch impressions in comparison to a conventional impression procedure in clinical use. Methods Four metal spheres were fixed with composite using a metal application aid to the lower teeth of 50 test subjects as reference structures. One conventional impression (Impregum Penta Soft) with subsequent type-IV gypsum model casting (CI) and three different digital impressions were performed in the lower jaw of each test person with the following intraoral scanners: Sirona CEREC Omnicam (OC), 3M True Definition (TD), Heraeus Cara TRIOS (cT). The digital and conventional (gypsum) models were analyzed relative to the spheres. Linear distance and angle measurements between the spheres, as well as digital superimpositions of the spheres with the reference data set were executed. Results With regard to the distance measurements, CI showed the smallest deviations followed by intraoral scanners TD, cT and OC. A digital superimposition procedure yielded the same order for the outcomes: CI (15 plus or minus 4 mu m), TD (23 plus or minus 9 mu m), cT (37 plus or minus 14 mu m), OC (214 plus or minus 38 mu m). Angle measurements revealed the smallest deviation for TD (0.06 degree plus or minus 0,07 degree ) followed by CI (0.07 degree plus or minus 0.07 degree ), cT (0.13 degree plus or minus 0.15 degree ) and OC (0.28 degree plus or minus 0.21 degree ). Conclusion The new measuring method is suitable for measuring the dimensional accuracy of full arch impressions intraorally. CI is still significantly more accurate than full arch scans with intraoral scanners in clinical use. Clinical significance Conventional full arch impressions with polyether impression materials are still more accurate than full arch digital impressions. Digital impression systems using powder application and active wavefront sampling technology achieve the most accurate results in comparison to other intraoral scanning systems (DRKS-ID: DRKS00009360, German Clinical Trials Register).
Abstract Objective To evaluate a new method of measuring the real deviation (trueness) of full arch impressions intraorally and to investigate the trueness of digital full arch impressions in comparison to a conventional impression procedure in clinical use. Methods Four metal spheres were fixed with composite using a metal application aid to the lower teeth of 50 test subjects as reference structures. One conventional impression (Impregum Penta Soft) with subsequent type-IV gypsum model casting (CI) and three different digital impressions were performed in the lower jaw of each test person with the following intraoral scanners: Sirona CEREC Omnicam (OC), 3 M True Definition (TD), Heraeus Cara TRIOS (cT). The digital and conventional (gypsum) models were analyzed relative to the spheres. Linear distance and angle measurements between the spheres, as well as digital superimpositions of the spheres with the reference data set were executed. Results With regard to the distance measurements, CI showed the smallest deviations followed by intraoral scanners TD, cT and OC. A digital superimposition procedure yielded the same order for the outcomes: CI (15 ± 4 μm), TD (23 ± 9 μm), cT (37 ± 14 μm), OC (214 ± 38 μm). Angle measurements revealed the smallest deviation for TD (0.06° ± 0,07°) followed by CI (0.07° ± 0.07°), cT (0.13° ± 0.15°) and OC (0.28° ± 0.21°). Conclusion The new measuring method is suitable for measuring the dimensional accuracy of full arch impressions intraorally. CI is still significantly more accurate than full arch scans with intraoral scanners in clinical use. Clinical significance Conventional full arch impressions with polyether impression materials are still more accurate than full arch digital impressions. Digital impression systems using powder application and active wavefront sampling technology achieve the most accurate results in comparison to other intraoral scanning systems (DRKS-ID: DRKS00009360, German Clinical Trials Register).
Author Wöstmann, B.
Kuhr, F.
Schmidt, A.
Rehmann, P.
Author_xml – sequence: 1
  givenname: F.
  surname: Kuhr
  fullname: Kuhr, F.
  email: fabian.j.kuhr@dentist.med.uni-giessen.de
  organization: Department of Prosthodontics, Justus-Liebig University, Schlangenzahl 14, D-35392 Giessen, Germany
– sequence: 2
  givenname: A.
  surname: Schmidt
  fullname: Schmidt, A.
  email: alexander.schmidt@dentist.med.uni-giessen.de
  organization: Department of Prosthodontics, Justus-Liebig University, Schlangenzahl 14, D-35392 Giessen, Germany
– sequence: 3
  givenname: P.
  surname: Rehmann
  fullname: Rehmann, P.
  email: Peter.Rehmann@dentist.med.uni-giessen.de
  organization: Department of Prosthodontics, Justus-Liebig University, Schlangenzahl 14, D-35392 Giessen, Germany
– sequence: 4
  givenname: B.
  surname: Wöstmann
  fullname: Wöstmann, B.
  email: bernd.woestmann@dentist.med.uni-giessen.de
  organization: Chair, Department of Prosthodontics, Justus-Liebig University, Schlangenzahl 14, D-35392 Giessen, Germany
BackLink https://www.ncbi.nlm.nih.gov/pubmed/27717754$$D View this record in MEDLINE/PubMed
BookMark eNqNklFrFDEUhYNU7Lb6CwQJ-OLLrDeTTDJBLJTSqrDggwq-hUwm42acSdZkRtl_b8ZtERa0fQq5fOfc5J57hk588Bah5wTWBAh_3a_71vppXeZLrqwBykdoRWohCyL41xO0AgpQVIKUp-gspR4AGJTyCTothSBCVGyFNpfY2194tNM2tLgLEeuUbErOf8PT1mJtzBy12ePQ4W4eBqyj2WI37uICBZ-w83inJ5dfkp6ix50ekn12e56jLzfXn6_eF5uP7z5cXW4Kw0s-FUZ2QteGNLKphJRcS82YERy6rm1YSaFuq7KlhHdSGFlx2QJIaMrGWs0JtPQcvTr47mL4Mds0qdElY4dBexvmpEjNWUU5o_UD0ApEzWrOH4DSbCppzTL68gjtwxx9_nOmGK-ZPPR-cUvNzWhbtYtu1HGv7qafAXkATAwpRdsp46Y8y-CnqN2gCKgladWrP0mrJemlmJPOWnqkvbP_v-rtQWVzPD-djSqZHJ2xrYvWTKoN7h79xZHeDM47o4fvdm_T3ymoVCpQn5YNXBaQcApE0sXgzb8N7m3_G-tR6Us
CitedBy_id crossref_primary_10_4047_jap_2021_13_4_191
crossref_primary_10_1016_j_prosdent_2019_04_004
crossref_primary_10_1007_s00784_021_04309_5
crossref_primary_10_1016_j_prosdent_2021_12_026
crossref_primary_10_3390_ijerph19031407
crossref_primary_10_1016_j_sdentj_2023_04_004
crossref_primary_10_1007_s00784_021_04335_3
crossref_primary_10_1016_j_compbiomed_2019_03_024
crossref_primary_10_2186_jpr_JPR_D_21_00100
crossref_primary_10_1111_cid_13336
crossref_primary_10_1016_j_prosdent_2020_04_019
crossref_primary_10_1111_jerd_13039
crossref_primary_10_1007_s00784_025_06236_1
crossref_primary_10_1016_j_prosdent_2022_02_020
crossref_primary_10_3390_ma13081990
crossref_primary_10_1007_s00784_022_04598_4
crossref_primary_10_1016_j_jpor_2019_06_006
crossref_primary_10_1186_s12903_023_03399_9
crossref_primary_10_1016_j_ultrasmedbio_2018_09_027
crossref_primary_10_21306_dishekimligi_1189450
crossref_primary_10_3390_app11157166
crossref_primary_10_1016_j_prosdent_2018_08_009
crossref_primary_10_1177_14653125211010815
crossref_primary_10_1038_s41598_020_58075_7
crossref_primary_10_3390_app10217637
crossref_primary_10_3390_app11115060
crossref_primary_10_4041_kjod_2021_51_2_95
crossref_primary_10_3390_jcm9030688
crossref_primary_10_1016_j_jdent_2023_104686
crossref_primary_10_1016_j_prosdent_2019_10_013
crossref_primary_10_1186_s40729_023_00516_9
crossref_primary_10_52037_eads_2024_0023
crossref_primary_10_1007_s00784_021_03777_z
crossref_primary_10_4047_jap_2021_13_4_205
crossref_primary_10_1155_2018_5189761
crossref_primary_10_1016_j_jdent_2024_105370
crossref_primary_10_1186_s12903_023_03476_z
crossref_primary_10_3390_app11104612
crossref_primary_10_1111_clr_13951
crossref_primary_10_1016_j_prosdent_2018_09_017
crossref_primary_10_1186_s40510_018_0205_5
crossref_primary_10_1016_j_prosdent_2019_10_023
crossref_primary_10_1111_clr_13715
crossref_primary_10_3390_app12052619
crossref_primary_10_1186_s12903_023_03101_z
crossref_primary_10_4041_kjod22_199
crossref_primary_10_1007_s00784_022_04721_5
crossref_primary_10_3390_app11031274
crossref_primary_10_15311_selcukdentj_1498338
crossref_primary_10_1016_j_prosdent_2018_09_021
crossref_primary_10_2186_jpr_JPR_D_20_00321
crossref_primary_10_1016_j_prosdent_2020_05_022
crossref_primary_10_1111_clr_13548
crossref_primary_10_1016_j_prosdent_2017_05_008
crossref_primary_10_1016_j_prosdent_2024_03_018
crossref_primary_10_3390_ma12121958
crossref_primary_10_1016_j_prosdent_2024_01_009
crossref_primary_10_3390_jcm11133723
crossref_primary_10_1016_j_prosdent_2020_03_021
crossref_primary_10_1016_j_prosdent_2020_09_038
crossref_primary_10_1111_jopr_13686
crossref_primary_10_2186_jpr_JPR_D_21_00023
crossref_primary_10_3390_ma13092034
crossref_primary_10_4047_jap_2019_11_2_138
crossref_primary_10_1186_s40510_022_00416_5
crossref_primary_10_1055_a_1539_0810
crossref_primary_10_4047_jap_2022_14_6_379
crossref_primary_10_1111_jopr_13727
crossref_primary_10_1111_clr_13498
crossref_primary_10_3390_dj12100313
crossref_primary_10_1186_s12903_018_0489_3
crossref_primary_10_3390_jcm12175508
crossref_primary_10_1016_j_jdent_2022_104308
crossref_primary_10_1016_j_jpor_2019_05_005
crossref_primary_10_1016_j_prosdent_2018_11_017
crossref_primary_10_1007_s12614_021_0125_5
crossref_primary_10_12968_denu_2020_47_9_719
crossref_primary_10_1016_j_prosdent_2018_07_014
crossref_primary_10_2186_jpr_JPR_D_22_00242
crossref_primary_10_1155_2021_5558158
crossref_primary_10_19127_mbsjohs_1301302
crossref_primary_10_2334_josnusd_23_0379
crossref_primary_10_1007_s00784_022_04607_6
crossref_primary_10_1186_s12903_020_01090_x
crossref_primary_10_7759_cureus_29055
crossref_primary_10_3390_healthcare9030246
crossref_primary_10_14347_kadt_2019_41_2_53
crossref_primary_10_1016_j_prosdent_2022_05_005
crossref_primary_10_1055_a_1200_0137
crossref_primary_10_1016_j_jdent_2017_12_006
crossref_primary_10_3390_ijerph17134725
crossref_primary_10_4047_jap_2019_11_6_331
crossref_primary_10_4103_jips_jips_327_19
crossref_primary_10_1111_jopr_13345
crossref_primary_10_1038_s41598_023_44033_6
crossref_primary_10_1177_14653125241268755
crossref_primary_10_3390_jcm12093071
crossref_primary_10_1016_j_prosdent_2021_01_021
crossref_primary_10_1111_jopr_13341
crossref_primary_10_3390_ijerph18199946
crossref_primary_10_1016_j_prosdent_2021_01_016
crossref_primary_10_3390_jcm9041098
crossref_primary_10_1007_s00784_019_02965_2
crossref_primary_10_1007_s00784_025_06154_2
crossref_primary_10_4047_jap_2021_13_5_316
crossref_primary_10_4047_jap_2022_14_2_88
Cites_doi 10.1016/j.dental.2008.01.008
10.1007/s00784-013-1132-y
10.4047/jap.2015.7.6.460
10.1007/s00784-015-1430-7
10.1016/S0022-3913(13)60038-4
10.1007/s00056-015-0296-2
10.1007/s00784-015-1513-5
10.1016/j.ajodo.2013.04.017
10.1016/j.ajodo.2014.07.023
10.1016/S0022-3913(13)60028-1
10.1016/j.prosdent.2015.09.011
10.1007/s00784-012-0795-0
10.1038/sj.bdj.2008.845
10.1371/journal.pone.0043312
10.1016/S0109-5641(02)00013-1
10.1016/j.jdent.2010.03.015
10.1007/s00784-016-1714-6
10.1016/j.prosdent.2015.11.007
ContentType Journal Article
Copyright 2016 Elsevier Ltd
Elsevier Ltd
Copyright © 2016 Elsevier Ltd. All rights reserved.
Copyright Elsevier Limited Dec 01, 2016
Copyright_xml – notice: 2016 Elsevier Ltd
– notice: Elsevier Ltd
– notice: Copyright © 2016 Elsevier Ltd. All rights reserved.
– notice: Copyright Elsevier Limited Dec 01, 2016
DBID AAYXX
CITATION
CGR
CUY
CVF
ECM
EIF
NPM
7QF
7QP
7QQ
7SE
7SR
7TA
7TB
8BQ
8FD
F28
FR3
H8G
JG9
K9.
7X8
DOI 10.1016/j.jdent.2016.10.002
DatabaseName CrossRef
Medline
MEDLINE
MEDLINE (Ovid)
MEDLINE
MEDLINE
PubMed
Aluminium Industry Abstracts
Calcium & Calcified Tissue Abstracts
Ceramic Abstracts
Corrosion Abstracts
Engineered Materials Abstracts
Materials Business File
Mechanical & Transportation Engineering Abstracts
METADEX
Technology Research Database
ANTE: Abstracts in New Technology & Engineering
Engineering Research Database
Copper Technical Reference Library
Materials Research Database
ProQuest Health & Medical Complete (Alumni)
MEDLINE - Academic
DatabaseTitle CrossRef
MEDLINE
Medline Complete
MEDLINE with Full Text
PubMed
MEDLINE (Ovid)
Materials Research Database
Aluminium Industry Abstracts
Technology Research Database
Mechanical & Transportation Engineering Abstracts
ProQuest Health & Medical Complete (Alumni)
Ceramic Abstracts
Materials Business File
METADEX
Copper Technical Reference Library
Engineered Materials Abstracts
Engineering Research Database
Calcium & Calcified Tissue Abstracts
Corrosion Abstracts
ANTE: Abstracts in New Technology & Engineering
MEDLINE - Academic
DatabaseTitleList MEDLINE - Academic
Materials Research Database
MEDLINE
Calcium & Calcified Tissue Abstracts



Materials Research Database
Database_xml – sequence: 1
  dbid: NPM
  name: PubMed
  url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed
  sourceTypes: Index Database
– sequence: 2
  dbid: EIF
  name: MEDLINE
  url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search
  sourceTypes: Index Database
DeliveryMethod fulltext_linktorsrc
Discipline Dentistry
EISSN 1879-176X
EndPage 74
ExternalDocumentID 4272565451
27717754
10_1016_j_jdent_2016_10_002
S0300571216301932
1_s2_0_S0300571216301932
Genre Journal Article
GeographicLocations Germany
GeographicLocations_xml – name: Germany
GroupedDBID ---
--K
--M
.1-
.FO
.~1
0R~
1B1
1P~
1RT
1~.
1~5
29K
34H
4.4
457
4G.
53G
5GY
5VS
7-5
71M
8FE
8FG
8FH
8P~
9JM
AABNK
AAEDT
AAEDW
AAGKA
AAIKJ
AAKOC
AALRI
AAOAW
AAQFI
AAQXK
AATTM
AAXKI
AAXUO
AAYWO
ABBQC
ABFNM
ABJNI
ABMAC
ABMZM
ABOCM
ABWVN
ABXDB
ACDAQ
ACGFS
ACIEU
ACIUM
ACIWK
ACPRK
ACRLP
ACRPL
ACVFH
ADBBV
ADCNI
ADEZE
ADMUD
ADNMO
ADVLN
AEBSH
AEIPS
AEKER
AENEX
AEUPX
AEVXI
AFFNX
AFJKZ
AFPUW
AFRHN
AFTJW
AFXIZ
AGCQF
AGHFR
AGQPQ
AGUBO
AGYEJ
AHHHB
AHMBA
AIEXJ
AIGII
AIIUN
AIKHN
AITUG
AJRQY
AJUYK
AKBMS
AKRWK
AKYEP
ALMA_UNASSIGNED_HOLDINGS
AMRAJ
ANKPU
ANZVX
APXCP
ASPBG
AVWKF
AXJTR
AZFZN
BKEYQ
BKOJK
BLXMC
BNPGV
BPHCQ
BVXVI
CS3
D-I
DU5
EBD
EBS
EFJIC
EFKBS
EJD
EO8
EO9
EP2
EP3
EX3
F5P
FDB
FEDTE
FGOYB
FIRID
FNPLU
FYGXN
G-2
G-Q
GBLVA
HDX
HMK
HMO
HVGLF
HZ~
IAO
IEA
IHE
IHR
INR
J1W
KOM
L6V
LH1
LK8
M29
M41
MO0
N9A
O-L
O9-
OAUVE
OB-
OM.
OZT
P-8
P-9
P2P
PC.
PQQKQ
PROAC
Q38
R2-
ROL
RPZ
SAE
SCC
SDF
SDG
SEL
SES
SEW
SPCBC
SSH
SSZ
T5K
WH7
WOW
WUQ
Z5R
ZGI
~G-
0SF
3V.
7RV
7X7
8FI
AACTN
ABJCF
AFCTW
AFKRA
AFKWA
AJOXV
AMFUW
AZQEC
BBNVY
BENPR
BHPHI
FYUFA
GUQSH
HCIFZ
M1P
M2O
M7P
M7S
NCXOZ
RIG
AAIAV
ABLVK
ABYKQ
AJBFU
EFLBG
LCYCR
AAYXX
AGRNS
CITATION
CGR
CUY
CVF
ECM
EIF
NPM
7QF
7QP
7QQ
7SE
7SR
7TA
7TB
8BQ
8FD
F28
FR3
H8G
JG9
K9.
7X8
ID FETCH-LOGICAL-c626t-c9f7a8c1b9b57996a9a44c760ffdb42308d52d316f97c9569d0090b2beea610d3
IEDL.DBID .~1
ISSN 0300-5712
1879-176X
IngestDate Fri Jul 11 10:15:50 EDT 2025
Fri Jul 11 08:35:26 EDT 2025
Thu Jul 10 23:32:11 EDT 2025
Wed Aug 13 10:54:06 EDT 2025
Wed Feb 19 02:30:12 EST 2025
Thu Apr 24 23:04:11 EDT 2025
Tue Jul 01 01:58:11 EDT 2025
Fri Feb 23 02:48:27 EST 2024
Tue Feb 25 20:09:48 EST 2025
Tue Aug 26 19:59:42 EDT 2025
IsPeerReviewed true
IsScholarly true
Keywords Polyether impression
Digital impression
Intraoral scanner
Full arch scan
CAD/CAM
Trueness
Language English
License Copyright © 2016 Elsevier Ltd. All rights reserved.
LinkModel DirectLink
MergedId FETCHMERGED-LOGICAL-c626t-c9f7a8c1b9b57996a9a44c760ffdb42308d52d316f97c9569d0090b2beea610d3
Notes ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
PMID 27717754
PQID 1846849438
PQPubID 1226341
PageCount 7
ParticipantIDs proquest_miscellaneous_1864536438
proquest_miscellaneous_1850784866
proquest_miscellaneous_1835369384
proquest_journals_1846849438
pubmed_primary_27717754
crossref_citationtrail_10_1016_j_jdent_2016_10_002
crossref_primary_10_1016_j_jdent_2016_10_002
elsevier_sciencedirect_doi_10_1016_j_jdent_2016_10_002
elsevier_clinicalkeyesjournals_1_s2_0_S0300571216301932
elsevier_clinicalkey_doi_10_1016_j_jdent_2016_10_002
ProviderPackageCode CITATION
AAYXX
PublicationCentury 2000
PublicationDate 2016-12-01
PublicationDateYYYYMMDD 2016-12-01
PublicationDate_xml – month: 12
  year: 2016
  text: 2016-12-01
  day: 01
PublicationDecade 2010
PublicationPlace England
PublicationPlace_xml – name: England
– name: Oxford
PublicationTitle Journal of dentistry
PublicationTitleAlternate J Dent
PublicationYear 2016
Publisher Elsevier Ltd
Elsevier Limited
Publisher_xml – name: Elsevier Ltd
– name: Elsevier Limited
References Patzelt, Emmanouilidi, Stampf, Strub, Att (bib0040) 2014; 18
Persson, Andersson, Oden, Sandborgh-Englund (bib0010) 2008; 24
Rhee, Huh, Cho, Park (bib0140) 2015; 7
Ender, Mehl (bib0055) 2015; 46
van der Meer, Andriessen, Wismeijer, Ren (bib0065) 2012; 7
Ireland, McNamara, Clover, House, Wenger, Barbour (bib0120) 2008; 205
Wöstmann, Lammert, Ferger (bib0090) 2002; 81
Güth, Keul, Stimmelmayr, Beuer, Edelhoff (bib0015) 2013; 17
Chandran, Jagger, Jagger, Barbour (bib0110) 2010; 20
Gimenez-Gonzalez, Hassan, Ozcan, Pradies (bib0095) 2016
Boeddinghaus, Breloer, Rehmann, Wostmann (bib0025) 2015; 19
Güth, Edelhoff, Schweiger, Keul (bib0060) 2015
Nassar, Oko, Adeeb, El-Rich, Flores-Mir (bib0100) 2013; 109
Jeong, Lee, Jeon, Kim, Kim, Kim (bib0035) 2016
Ender, Mehl (bib0050) 2013; 109
Vogel, Kilic, Schmidt, Rubel, Lapatki (bib0105) 2015; 76
Ender, Zimmermann, Attin, Mehl (bib0130) 2015
Ueda, Beuer, Stimmelmayr, Erdelt, Keul, Güth (bib0005) 2016; 20
Flügge, Schlager, Nelson, Nahles, Metzger (bib0070) 2013; 144
Berrendero, Salido, Valverde, Ferreiroa, Pradies (bib0020) 2016
Luthardt, Kuhmstedt, Walter (bib0115) 2003; 19
Karl, Winter, Taylor, Heckmann (bib0125) 2004; 19
Syrek, Reich, Ranftl, Klein, Cerny, Brodesser (bib0030) 2010; 38
Grünheid, McCarthy, Larson (bib0085) 2014; 146
Ender, Attin, Mehl (bib0080) 2016; 115
Müller, Ender, Joda, Katsoulis (bib0075) 2016; 47
Rudolph, Quaas, Luthardt (bib0135) 2002; 5
Ender, Mehl (bib0045) 2011; 14
Grünheid (10.1016/j.jdent.2016.10.002_bib0085) 2014; 146
Ireland (10.1016/j.jdent.2016.10.002_bib0120) 2008; 205
Persson (10.1016/j.jdent.2016.10.002_bib0010) 2008; 24
Luthardt (10.1016/j.jdent.2016.10.002_bib0115) 2003; 19
Ender (10.1016/j.jdent.2016.10.002_bib0045) 2011; 14
Nassar (10.1016/j.jdent.2016.10.002_bib0100) 2013; 109
Ender (10.1016/j.jdent.2016.10.002_bib0130) 2015
Ueda (10.1016/j.jdent.2016.10.002_bib0005) 2016; 20
Flügge (10.1016/j.jdent.2016.10.002_bib0070) 2013; 144
Wöstmann (10.1016/j.jdent.2016.10.002_bib0090) 2002; 81
Berrendero (10.1016/j.jdent.2016.10.002_bib0020) 2016
Rhee (10.1016/j.jdent.2016.10.002_bib0140) 2015; 7
Boeddinghaus (10.1016/j.jdent.2016.10.002_bib0025) 2015; 19
Chandran (10.1016/j.jdent.2016.10.002_bib0110) 2010; 20
Syrek (10.1016/j.jdent.2016.10.002_bib0030) 2010; 38
Ender (10.1016/j.jdent.2016.10.002_bib0055) 2015; 46
Ender (10.1016/j.jdent.2016.10.002_bib0080) 2016; 115
Patzelt (10.1016/j.jdent.2016.10.002_bib0040) 2014; 18
Vogel (10.1016/j.jdent.2016.10.002_bib0105) 2015; 76
Güth (10.1016/j.jdent.2016.10.002_bib0015) 2013; 17
Müller (10.1016/j.jdent.2016.10.002_bib0075) 2016; 47
Gimenez-Gonzalez (10.1016/j.jdent.2016.10.002_bib0095) 2016
Rudolph (10.1016/j.jdent.2016.10.002_bib0135) 2002; 5
van der Meer (10.1016/j.jdent.2016.10.002_bib0065) 2012; 7
Ender (10.1016/j.jdent.2016.10.002_bib0050) 2013; 109
Güth (10.1016/j.jdent.2016.10.002_bib0060) 2015
Karl (10.1016/j.jdent.2016.10.002_bib0125) 2004; 19
Jeong (10.1016/j.jdent.2016.10.002_bib0035) 2016
References_xml – volume: 7
  start-page: 460
  year: 2015
  end-page: 467
  ident: bib0140
  article-title: Comparison of intraoral scanning and conventional impression techniques using 3-dimensional superimposition
  publication-title: J. Adv. Prosthodont.
– volume: 47
  start-page: 343
  year: 2016
  end-page: 349
  ident: bib0075
  article-title: Impact of digital intraoral scan strategies on the impression accuracy using the TRIOS Pod scanner
  publication-title: Quintessence Int.
– volume: 46
  start-page: 9
  year: 2015
  end-page: 17
  ident: bib0055
  article-title: In-vitro evaluation of the accuracy of conventional and digital methods of obtaining full-arch dental impressions
  publication-title: Quintessence Int.
– volume: 205
  start-page: 387
  year: 2008
  end-page: 392
  ident: bib0120
  article-title: 3D surface imaging in dentistry − what we are looking at
  publication-title: Br. Dent. J.
– year: 2015
  ident: bib0130
  article-title: In vivo precision of conventional and digital methods for obtaining quadrant dental impressions
  publication-title: Clin. Oral Investig.
– volume: 20
  start-page: 243
  year: 2010
  end-page: 249
  ident: bib0110
  article-title: Two- and three-dimensional accuracy of dental impression materials: effects of storage time and moisture contamination
  publication-title: Biomed. Mater. Eng.
– volume: 144
  start-page: 471
  year: 2013
  end-page: 478
  ident: bib0070
  article-title: Precision of intraoral digital dental impressions with iTero and extraoral digitization with the iTero and a model scanner
  publication-title: Am. J. Orthod. Dentofacial Orthop.
– volume: 109
  start-page: 172
  year: 2013
  end-page: 178
  ident: bib0100
  article-title: An in vitro study on the dimensional stability of a vinyl polyether silicone impression material over a prolonged storage period
  publication-title: J. Prosthet. Dent.
– volume: 24
  start-page: 1123
  year: 2008
  end-page: 1130
  ident: bib0010
  article-title: Computer aided analysis of digitized dental stone replicas by dental CAD/CAM technology
  publication-title: Dent. Mater.
– volume: 76
  start-page: 351
  year: 2015
  end-page: 365
  ident: bib0105
  article-title: Dimensional accuracy of jaw scans performed on alginate impressions or stone models: a practice-oriented study
  publication-title: J. Orofac. Orthop.
– year: 2016
  ident: bib0020
  article-title: Influence of conventional and digital intraoral impressions on the fit of CAD/CAM-fabricated all-ceramic crowns
  publication-title: Clin. Oral Investig.
– volume: 18
  start-page: 1687
  year: 2014
  end-page: 1694
  ident: bib0040
  article-title: Accuracy of full-arch scans using intraoral scanners
  publication-title: Clin. Oral Investig.
– volume: 17
  start-page: 1201
  year: 2013
  end-page: 1208
  ident: bib0015
  article-title: Accuracy of digital models obtained by direct and indirect data capturing
  publication-title: Clin. Oral Investig.
– volume: 115
  start-page: 313
  year: 2016
  end-page: 320
  ident: bib0080
  article-title: In vivo precision of conventional and digital methods of obtaining complete-arch dental impressions
  publication-title: J. Prosthet. Dent.
– volume: 19
  start-page: 2027
  year: 2015
  end-page: 2034
  ident: bib0025
  article-title: Accuracy of single-tooth restorations based on intraoral digital and conventional impressions in patients
  publication-title: Clin. Oral Investig.
– volume: 38
  start-page: 553
  year: 2010
  end-page: 559
  ident: bib0030
  article-title: Clinical evaluation of all-ceramic crowns fabricated from intraoral digital impressions based on the principle of active wavefront sampling
  publication-title: J. Dent.
– volume: 20
  start-page: 283
  year: 2016
  end-page: 289
  ident: bib0005
  article-title: Fit of 4-unit FDPs from CoCr and zirconia after conventional and digital impressions
  publication-title: Clin. Oral Investig.
– volume: 19
  start-page: 30
  year: 2004
  end-page: 37
  ident: bib0125
  article-title: In vitro study on passive fit in implant-supported 5-unit fixed partial dentures
  publication-title: Int. J. Oral Maxillofac. Implants
– volume: 5
  start-page: 155
  year: 2002
  end-page: 164
  ident: bib0135
  article-title: Matching point clouds: limits and possibilities
  publication-title: Int. J. Comput. Dent.
– year: 2015
  ident: bib0060
  article-title: A new method for the evaluation of the accuracy of full-arch digital impressions in vitro
  publication-title: Clin. Oral Investig.
– year: 2016
  ident: bib0035
  article-title: Accuracy of complete-arch model using an intraoral video scanner: an in vitro study
  publication-title: J. Prosthet. Dent.
– volume: 14
  start-page: 11
  year: 2011
  end-page: 21
  ident: bib0045
  article-title: Full arch scans: conventional versus digital impressions–an in-vitro study
  publication-title: Int. J. Comput. Dent.
– year: 2016
  ident: bib0095
  article-title: An In vitro study of factors influencing the performance of digital intraoral impressions operating on active wavefront sampling technology with multiple implants in the edentulous maxilla
  publication-title: J. Prosthodont.
– volume: 81
  start-page: A
  year: 2002
  end-page: 60
  ident: bib0090
  article-title: Analysis of fit of stock trays for dentate jaws
  publication-title: J. Dent. Res.
– volume: 7
  start-page: e43312
  year: 2012
  ident: bib0065
  article-title: Application of intra-oral dental scanners in the digital workflow of implantology
  publication-title: PLoS One
– volume: 19
  start-page: 19
  year: 2003
  end-page: 24
  ident: bib0115
  article-title: A new method for the computer-aided evaluation of three-dimensional changes in gypsum materials
  publication-title: Dent. Mater.
– volume: 109
  start-page: 121
  year: 2013
  end-page: 128
  ident: bib0050
  article-title: Accuracy of complete-arch dental impressions: a new method of measuring trueness and precision
  publication-title: J. Prosthet. Dent.
– volume: 146
  start-page: 673
  year: 2014
  end-page: 682
  ident: bib0085
  article-title: Clinical use of a direct chairside oral scanner: an assessment of accuracy, time, and patient acceptance
  publication-title: Am. J. Orthod. Dentofacial Orthop.
– volume: 24
  start-page: 1123
  year: 2008
  ident: 10.1016/j.jdent.2016.10.002_bib0010
  article-title: Computer aided analysis of digitized dental stone replicas by dental CAD/CAM technology
  publication-title: Dent. Mater.
  doi: 10.1016/j.dental.2008.01.008
– volume: 18
  start-page: 1687
  year: 2014
  ident: 10.1016/j.jdent.2016.10.002_bib0040
  article-title: Accuracy of full-arch scans using intraoral scanners
  publication-title: Clin. Oral Investig.
  doi: 10.1007/s00784-013-1132-y
– volume: 46
  start-page: 9
  year: 2015
  ident: 10.1016/j.jdent.2016.10.002_bib0055
  article-title: In-vitro evaluation of the accuracy of conventional and digital methods of obtaining full-arch dental impressions
  publication-title: Quintessence Int.
– volume: 7
  start-page: 460
  year: 2015
  ident: 10.1016/j.jdent.2016.10.002_bib0140
  article-title: Comparison of intraoral scanning and conventional impression techniques using 3-dimensional superimposition
  publication-title: J. Adv. Prosthodont.
  doi: 10.4047/jap.2015.7.6.460
– volume: 14
  start-page: 11
  year: 2011
  ident: 10.1016/j.jdent.2016.10.002_bib0045
  article-title: Full arch scans: conventional versus digital impressions–an in-vitro study
  publication-title: Int. J. Comput. Dent.
– year: 2016
  ident: 10.1016/j.jdent.2016.10.002_bib0095
  article-title: An In vitro study of factors influencing the performance of digital intraoral impressions operating on active wavefront sampling technology with multiple implants in the edentulous maxilla
  publication-title: J. Prosthodont.
– volume: 19
  start-page: 2027
  year: 2015
  ident: 10.1016/j.jdent.2016.10.002_bib0025
  article-title: Accuracy of single-tooth restorations based on intraoral digital and conventional impressions in patients
  publication-title: Clin. Oral Investig.
  doi: 10.1007/s00784-015-1430-7
– year: 2015
  ident: 10.1016/j.jdent.2016.10.002_bib0060
  article-title: A new method for the evaluation of the accuracy of full-arch digital impressions in vitro
  publication-title: Clin. Oral Investig.
– volume: 109
  start-page: 172
  year: 2013
  ident: 10.1016/j.jdent.2016.10.002_bib0100
  article-title: An in vitro study on the dimensional stability of a vinyl polyether silicone impression material over a prolonged storage period
  publication-title: J. Prosthet. Dent.
  doi: 10.1016/S0022-3913(13)60038-4
– volume: 76
  start-page: 351
  year: 2015
  ident: 10.1016/j.jdent.2016.10.002_bib0105
  article-title: Dimensional accuracy of jaw scans performed on alginate impressions or stone models: a practice-oriented study
  publication-title: J. Orofac. Orthop.
  doi: 10.1007/s00056-015-0296-2
– volume: 20
  start-page: 283
  year: 2016
  ident: 10.1016/j.jdent.2016.10.002_bib0005
  article-title: Fit of 4-unit FDPs from CoCr and zirconia after conventional and digital impressions
  publication-title: Clin. Oral Investig.
  doi: 10.1007/s00784-015-1513-5
– volume: 144
  start-page: 471
  year: 2013
  ident: 10.1016/j.jdent.2016.10.002_bib0070
  article-title: Precision of intraoral digital dental impressions with iTero and extraoral digitization with the iTero and a model scanner
  publication-title: Am. J. Orthod. Dentofacial Orthop.
  doi: 10.1016/j.ajodo.2013.04.017
– volume: 146
  start-page: 673
  year: 2014
  ident: 10.1016/j.jdent.2016.10.002_bib0085
  article-title: Clinical use of a direct chairside oral scanner: an assessment of accuracy, time, and patient acceptance
  publication-title: Am. J. Orthod. Dentofacial Orthop.
  doi: 10.1016/j.ajodo.2014.07.023
– volume: 5
  start-page: 155
  year: 2002
  ident: 10.1016/j.jdent.2016.10.002_bib0135
  article-title: Matching point clouds: limits and possibilities
  publication-title: Int. J. Comput. Dent.
– volume: 109
  start-page: 121
  year: 2013
  ident: 10.1016/j.jdent.2016.10.002_bib0050
  article-title: Accuracy of complete-arch dental impressions: a new method of measuring trueness and precision
  publication-title: J. Prosthet. Dent.
  doi: 10.1016/S0022-3913(13)60028-1
– volume: 19
  start-page: 30
  year: 2004
  ident: 10.1016/j.jdent.2016.10.002_bib0125
  article-title: In vitro study on passive fit in implant-supported 5-unit fixed partial dentures
  publication-title: Int. J. Oral Maxillofac. Implants
– volume: 115
  start-page: 313
  year: 2016
  ident: 10.1016/j.jdent.2016.10.002_bib0080
  article-title: In vivo precision of conventional and digital methods of obtaining complete-arch dental impressions
  publication-title: J. Prosthet. Dent.
  doi: 10.1016/j.prosdent.2015.09.011
– volume: 17
  start-page: 1201
  year: 2013
  ident: 10.1016/j.jdent.2016.10.002_bib0015
  article-title: Accuracy of digital models obtained by direct and indirect data capturing
  publication-title: Clin. Oral Investig.
  doi: 10.1007/s00784-012-0795-0
– volume: 205
  start-page: 387
  year: 2008
  ident: 10.1016/j.jdent.2016.10.002_bib0120
  article-title: 3D surface imaging in dentistry − what we are looking at
  publication-title: Br. Dent. J.
  doi: 10.1038/sj.bdj.2008.845
– volume: 47
  start-page: 343
  year: 2016
  ident: 10.1016/j.jdent.2016.10.002_bib0075
  article-title: Impact of digital intraoral scan strategies on the impression accuracy using the TRIOS Pod scanner
  publication-title: Quintessence Int.
– volume: 81
  start-page: A
  year: 2002
  ident: 10.1016/j.jdent.2016.10.002_bib0090
  article-title: Analysis of fit of stock trays for dentate jaws
  publication-title: J. Dent. Res.
– volume: 7
  start-page: e43312
  year: 2012
  ident: 10.1016/j.jdent.2016.10.002_bib0065
  article-title: Application of intra-oral dental scanners in the digital workflow of implantology
  publication-title: PLoS One
  doi: 10.1371/journal.pone.0043312
– volume: 19
  start-page: 19
  year: 2003
  ident: 10.1016/j.jdent.2016.10.002_bib0115
  article-title: A new method for the computer-aided evaluation of three-dimensional changes in gypsum materials
  publication-title: Dent. Mater.
  doi: 10.1016/S0109-5641(02)00013-1
– volume: 38
  start-page: 553
  year: 2010
  ident: 10.1016/j.jdent.2016.10.002_bib0030
  article-title: Clinical evaluation of all-ceramic crowns fabricated from intraoral digital impressions based on the principle of active wavefront sampling
  publication-title: J. Dent.
  doi: 10.1016/j.jdent.2010.03.015
– year: 2016
  ident: 10.1016/j.jdent.2016.10.002_bib0020
  article-title: Influence of conventional and digital intraoral impressions on the fit of CAD/CAM-fabricated all-ceramic crowns
  publication-title: Clin. Oral Investig.
  doi: 10.1007/s00784-016-1714-6
– year: 2016
  ident: 10.1016/j.jdent.2016.10.002_bib0035
  article-title: Accuracy of complete-arch model using an intraoral video scanner: an in vitro study
  publication-title: J. Prosthet. Dent.
  doi: 10.1016/j.prosdent.2015.11.007
– year: 2015
  ident: 10.1016/j.jdent.2016.10.002_bib0130
  article-title: In vivo precision of conventional and digital methods for obtaining quadrant dental impressions
  publication-title: Clin. Oral Investig.
– volume: 20
  start-page: 243
  year: 2010
  ident: 10.1016/j.jdent.2016.10.002_bib0110
  article-title: Two- and three-dimensional accuracy of dental impression materials: effects of storage time and moisture contamination
  publication-title: Biomed. Mater. Eng.
SSID ssj0004029
Score 2.5085444
Snippet To evaluate a new method of measuring the real deviation (trueness) of full arch impressions intraorally and to investigate the trueness of digital full arch...
Abstract Objective To evaluate a new method of measuring the real deviation (trueness) of full arch impressions intraorally and to investigate the trueness of...
Objective To evaluate a new method of measuring the real deviation (trueness) of full arch impressions intraorally and to investigate the trueness of digital...
SourceID proquest
pubmed
crossref
elsevier
SourceType Aggregation Database
Index Database
Enrichment Source
Publisher
StartPage 68
SubjectTerms Accuracy
Algorithms
Arches
CAD/CAM
Computer aided tomography
Computer-Aided Design
Dental Arch
Dental Impression Materials
Dental Impression Technique
Dental Models
Dentistry
Deviation
Digital
Digital impression
Digitization
Full arch scan
Gypsum
Heraeus
Humans
Imaging, Three-Dimensional
Intraoral scanner
Laboratories
Polyether impression
Scanners
Software
Spheres
Statistical analysis
Studies
Teeth
Trueness
Title A new method for assessing the accuracy of full arch impressions in patients
URI https://www.clinicalkey.com/#!/content/1-s2.0-S0300571216301932
https://www.clinicalkey.es/playcontent/1-s2.0-S0300571216301932
https://dx.doi.org/10.1016/j.jdent.2016.10.002
https://www.ncbi.nlm.nih.gov/pubmed/27717754
https://www.proquest.com/docview/1846849438
https://www.proquest.com/docview/1835369384
https://www.proquest.com/docview/1850784866
https://www.proquest.com/docview/1864536438
Volume 55
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1LbxMxELaqcoAL4k2gVEbiyDZee9aPY1QI4dULVOrNsr22lAo2VTc59NLfzngfqRA0SFwiZXccb8bj8Tfrb8aEvEmO8wRQFbVwqQAlWeGEgqKOVYpcs-h8Tk7-eiIXp_DprDrbI8djLkymVQ6-v_fpnbcerkwHbU4vlsvpN5YrrauSI6JgGYbkDHbsDG366PqG5oHxkel3EliRpcfKQx3H6zwnw2Z-lzzqKF78ttXpNvTZrULzB-T-AB_prH_Ch2QvNo_I3XeZ8pNPbXtMvswoAmXaHwxNEZFS123r4gpFEetRF8Lm0oUruko0v3qn2dDp8ufAh21aumzoUGy1fUJO5--_Hy-K4cSEImBgsi6CScrpUHrjK4WRjDMOIOAApFR7BE5M1xWvRSmTUQEjI1MjxGKe-xgd4qhaPCX7zaqJzwlFqOA4BB_KFCAxbwJUyWHALIUXDsSE8FFTNgzlxPOpFj_syBs7t516bVZvvojqnZC320YXfTWN3eIwDoEdE0XRtVn09rubqb81i-0wPVtb2pZbZv8woQmR25a_WeG_uzwYLcTe9ILYToMBoSfk9fY2Tt-8J-OauNpkGVEJaYSGXTII2jVoKXfJSMAf6vp61lvoVsNcYcyuKnjxv__uJbmXv_UsngOyv77cxFeIxdb-sJts-KnnHw7JndnHz4uTXzKgMrg
linkProvider Elsevier
linkToHtml http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV3db9MwED-N7mG8IL4pDDASj4QmtuMkj9Vg6ljXFzZpb5bt2FKnkU5L-8B_z13idEKwIvFq38XJ5Xz-XXIfAB-D4TxImSe1MCGRhUoTIwqZ1D4PnpepN5aSk88WanYhv13ml3twNOTCUFhltP29Te-sdRyZRGlObpbLyfeUKq0XGUdEkRIMeQD7VJ0qH8H-9OR0trhLj0y7ZmVEnxDDUHyoC_O6onxYCvFSn7soL37fAXUfAO0OouPH8CgiSDbtb_IJ7PnmKRx8oagfatz2DOZThliZ9b2hGYJSZro_u3hIMYR7zDi3uTXuJ1sFRl_fGek6W_6IIbFNy5YNi_VW2-dwcfz1_GiWxKYJiUPfZJ24KhSmdJmtbF6gM2MqI6XDdxBCbRE7pWWd81pkKlSFQ-eoqhFlpZZb7w1CqVq8gFGzavwrYIgWDJfOuiw4GVJbOZkHgz6zElYYKcbAB0lpFyuKU2OLaz2Ejl3pTryaxEuDKN4xfNoy3fQFNXaTy-EV6CFXFK2bRoO_m634G5tv4w5tdaZbrlP9hxaNQW05f1PEfy95OGiIvlsF4V0pKynKMXzYTuMOpt8ypvGrDdGIXKhKlHIXDeL2UpZK7aJREi_UrfWy19CthHmBbnuRy9f_-3Tv4WB2fjbX85PF6Rt4SDN9UM8hjNa3G_8Wodnavotb7xdrLTSD
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=A+new+method+for+assessing+the+accuracy+of+full+arch+impressions+in+patients&rft.jtitle=Journal+of+dentistry&rft.au=Kuhr%2C+F&rft.au=Schmidt%2C+A&rft.au=Rehmann%2C+P&rft.au=Wostmann%2C+B&rft.date=2016-12-01&rft.issn=0300-5712&rft.volume=55&rft.spage=68&rft.epage=74&rft_id=info:doi/10.1016%2Fj.jdent.2016.10.002&rft.externalDBID=NO_FULL_TEXT
thumbnail_m http://utb.summon.serialssolutions.com/2.0.0/image/custom?url=https%3A%2F%2Fcdn.clinicalkey.com%2Fck-thumbnails%2F03005712%2FS0300571216X00127%2Fcov150h.gif