Effect of cycloplegia on corneal biometrics and refractive state
Purpose: To determine changes in refractive state and corneal parameters after cycloplegia with cyclopentolate hydrochloride 1% using a dual Scheimpflug imaging system. Methods: In this prospective cross-sectional study patients aged 10 to 40 years who were referred for optometric evaluation enrolle...
Saved in:
Published in | Journal of ophthalmic & vision research Vol. 13; no. 2; pp. 101 - 109 |
---|---|
Main Authors | , , , , , |
Format | Journal Article |
Language | English |
Published |
India
Wolters Kluwer India Pvt. Ltd
01.04.2018
Medknow Publications and Media Pvt. Ltd Medknow Publications & Media Pvt. Ltd Medknow Publications & Media Pvt Ltd Knowledge E |
Subjects | |
Online Access | Get full text |
Cover
Loading…
Abstract | Purpose: To determine changes in refractive state and corneal parameters after cycloplegia with cyclopentolate hydrochloride 1% using a dual Scheimpflug imaging system.
Methods: In this prospective cross-sectional study patients aged 10 to 40 years who were referred for optometric evaluation enrolled and underwent autorefraction and corneal imaging with the Galilei dual Scheimpflug system before and 30 minutes after twice instillation of medication. Changes in refraction and astigmatism were investigated. Corneal biometrics including anterior and posterior corneal curvatures, total corneal power and corneal pachymetry were compared before and after cycloplegia.
Results: Two hundred and twelve eyes of 106 subjects with mean age of 28 ± 5 years including 201 myopic and 11 hyperopic eyes were evaluated. Mean spherical equivalent refractive error before cycloplegia was -3.4 ± 2.6 D. A mean hyperopic shift of 0.4 ± 0.5 D occurred after cycloplegia (P < 0.001). The astigmatism power did not significantly change (P = 0.8), however, 26.8% of eyes with significant astigmatism experienced a change of more than 5 degrees in the axis of astigmatism. Changes in posterior corneal curvature were scant but statistically significant (P = 0.001). Moreover, corneal thickness was slightly increased in the central and paracentral regions (P < 0.001 and P < 0.001, respectively).
Conclusion: Cycloplegia causes a hyperopic shift and astigmatism axis changes, along with an increase in central and paracentral corneal thickness and change in posterior corneal curvature. The effects of cycloplegia on refraction and corneal biometrics should be considered before cataract and refractive surgeries. |
---|---|
AbstractList | Purpose: To determine changes in refractive state and corneal parameters after cycloplegia with cyclopentolate hydrochloride 1% using a dual Scheimpflug imaging system. Methods: In this prospective cross-sectional study patients aged 10 to 40 years who were referred for optometric evaluation enrolled and underwent autorefraction and corneal imaging with the Galilei dual Scheimpflug system before and 30 minutes after twice instillation of medication. Changes in refraction and astigmatism were investigated. Corneal biometrics including anterior and posterior corneal curvatures, total corneal power and corneal pachymetry were compared before and after cycloplegia. Results: Two hundred and twelve eyes of 106 subjects with mean age of 28 +- 5 years including 201 myopic and 11 hyperopic eyes were evaluated. Mean spherical equivalent refractive error before cycloplegia was -3.4 +- 2.6 D. A mean hyperopic shift of 0.4 +- 0.5 D occurred after cycloplegia (P < 0.001). The astigmatism power did not significantly change (P = 0.8), however, 26.8% of eyes with significant astigmatism experienced a change of more than 5 degrees in the axis of astigmatism. Changes in posterior corneal curvature were scant but statistically significant (P = 0.001). Moreover, corneal thickness was slightly increased in the central and paracentral regions (P < 0.001 and P < 0.001, respectively). Conclusion: Cycloplegia causes a hyperopic shift and astigmatism axis changes, along with an increase in central and paracentral corneal thickness and change in posterior corneal curvature. The effects of cycloplegia on refraction and corneal biometrics should be considered before cataract and refractive surgeries. To determine changes in refractive state and corneal parameters after cycloplegia with cyclopentolate hydrochloride 1% using a dual Scheimpflug imaging system.PURPOSETo determine changes in refractive state and corneal parameters after cycloplegia with cyclopentolate hydrochloride 1% using a dual Scheimpflug imaging system.In this prospective cross-sectional study patients aged 10 to 40 years who were referred for optometric evaluation enrolled and underwent autorefraction and corneal imaging with the Galilei dual Scheimpflug system before and 30 minutes after twice instillation of medication. Changes in refraction and astigmatism were investigated. Corneal biometrics including anterior and posterior corneal curvatures, total corneal power and corneal pachymetry were compared before and after cycloplegia.METHODSIn this prospective cross-sectional study patients aged 10 to 40 years who were referred for optometric evaluation enrolled and underwent autorefraction and corneal imaging with the Galilei dual Scheimpflug system before and 30 minutes after twice instillation of medication. Changes in refraction and astigmatism were investigated. Corneal biometrics including anterior and posterior corneal curvatures, total corneal power and corneal pachymetry were compared before and after cycloplegia.Two hundred and twelve eyes of 106 subjects with mean age of 28 ± 5 years including 201 myopic and 11 hyperopic eyes were evaluated. Mean spherical equivalent refractive error before cycloplegia was -3.4 ± 2.6 D. A mean hyperopic shift of 0.4 ± 0.5 D occurred after cycloplegia (P < 0.001). The astigmatism power did not significantly change (P = 0.8), however, 26.8% of eyes with significant astigmatism experienced a change of more than 5 degrees in the axis of astigmatism. Changes in posterior corneal curvature were scant but statistically significant (P = 0.001). Moreover, corneal thickness was slightly increased in the central and paracentral regions (P < 0.001 and P < 0.001, respectively).RESULTSTwo hundred and twelve eyes of 106 subjects with mean age of 28 ± 5 years including 201 myopic and 11 hyperopic eyes were evaluated. Mean spherical equivalent refractive error before cycloplegia was -3.4 ± 2.6 D. A mean hyperopic shift of 0.4 ± 0.5 D occurred after cycloplegia (P < 0.001). The astigmatism power did not significantly change (P = 0.8), however, 26.8% of eyes with significant astigmatism experienced a change of more than 5 degrees in the axis of astigmatism. Changes in posterior corneal curvature were scant but statistically significant (P = 0.001). Moreover, corneal thickness was slightly increased in the central and paracentral regions (P < 0.001 and P < 0.001, respectively).Cycloplegia causes a hyperopic shift and astigmatism axis changes, along with an increase in central and paracentral corneal thickness and change in posterior corneal curvature. The effects of cycloplegia on refraction and corneal biometrics should be considered before cataract and refractive surgeries.CONCLUSIONCycloplegia causes a hyperopic shift and astigmatism axis changes, along with an increase in central and paracentral corneal thickness and change in posterior corneal curvature. The effects of cycloplegia on refraction and corneal biometrics should be considered before cataract and refractive surgeries. Purpose: To determine changes in refractive state and corneal parameters after cycloplegia with cyclopentolate hydrochloride 1% using a dual Scheimpflug imaging system. Methods: In this prospective cross-sectional study patients aged 10 to 40 years who were referred for optometric evaluation enrolled and underwent autorefraction and corneal imaging with the Galilei dual Scheimpflug system before and 30 minutes after twice instillation of medication. Changes in refraction and astigmatism were investigated. Corneal biometrics including anterior and posterior corneal curvatures, total corneal power and corneal pachymetry were compared before and after cycloplegia. Results: Two hundred and twelve eyes of 106 subjects with mean age of 28 ± 5 years including 201 myopic and 11 hyperopic eyes were evaluated. Mean spherical equivalent refractive error before cycloplegia was -3.4 ± 2.6 D. A mean hyperopic shift of 0.4 ± 0.5 D occurred after cycloplegia (P < 0.001). The astigmatism power did not significantly change (P = 0.8), however, 26.8% of eyes with significant astigmatism experienced a change of more than 5 degrees in the axis of astigmatism. Changes in posterior corneal curvature were scant but statistically significant (P = 0.001). Moreover, corneal thickness was slightly increased in the central and paracentral regions (P < 0.001 and P < 0.001, respectively). Conclusion: Cycloplegia causes a hyperopic shift and astigmatism axis changes, along with an increase in central and paracentral corneal thickness and change in posterior corneal curvature. The effects of cycloplegia on refraction and corneal biometrics should be considered before cataract and refractive surgeries. Purpose: To determine changes in refractive state and corneal parameters after cycloplegia with cyclopentolate hydrochloride 1% using a dual Scheimpflug imaging system. Methods: In this prospective cross-sectional study patients aged 10 to 40 years who were referred for optometric evaluation enrolled and underwent autorefraction and corneal imaging with the Galilei dual Scheimpflug system before and 30 minutes after twice instillation of medication. Changes in refraction and astigmatism were investigated. Corneal biometrics including anterior and posterior corneal curvatures, total corneal power and corneal pachymetry were compared before and after cycloplegia. Results: Two hundred and twelve eyes of 106 subjects with mean age of 28 ± 5 years including 201 myopic and 11 hyperopic eyes were evaluated. Mean spherical equivalent refractive error before cycloplegia was -3.4 ± 2.6 D. A mean hyperopic shift of 0.4 ± 0.5 D occurred after cycloplegia (P < 0.001). The astigmatism power did not significantly change (P = 0.8), however, 26.8% of eyes with significant astigmatism experienced a change of more than 5 degrees in the axis of astigmatism. Changes in posterior corneal curvature were scant but statistically significant (P = 0.001). Moreover, corneal thickness was slightly increased in the central and paracentral regions (P < 0.001 and P < 0.001, respectively). Conclusion: Cycloplegia causes a hyperopic shift and astigmatism axis changes, along with an increase in central and paracentral corneal thickness and change in posterior corneal curvature. The effects of cycloplegia on refraction and corneal biometrics should be considered before cataract and refractive surgeries. To determine changes in refractive state and corneal parameters after cycloplegia with cyclopentolate hydrochloride 1% using a dual Scheimpflug imaging system. In this prospective cross-sectional study patients aged 10 to 40 years who were referred for optometric evaluation enrolled and underwent autorefraction and corneal imaging with the Galilei dual Scheimpflug system before and 30 minutes after twice instillation of medication. Changes in refraction and astigmatism were investigated. Corneal biometrics including anterior and posterior corneal curvatures, total corneal power and corneal pachymetry were compared before and after cycloplegia. Two hundred and twelve eyes of 106 subjects with mean age of 28 ± 5 years including 201 myopic and 11 hyperopic eyes were evaluated. Mean spherical equivalent refractive error before cycloplegia was -3.4 ± 2.6 D. A mean hyperopic shift of 0.4 ± 0.5 D occurred after cycloplegia ( < 0.001). The astigmatism power did not significantly change ( = 0.8), however, 26.8% of eyes with significant astigmatism experienced a change of more than 5 degrees in the axis of astigmatism. Changes in posterior corneal curvature were scant but statistically significant ( = 0.001). Moreover, corneal thickness was slightly increased in the central and paracentral regions ( < 0.001 and < 0.001, respectively). Cycloplegia causes a hyperopic shift and astigmatism axis changes, along with an increase in central and paracentral corneal thickness and change in posterior corneal curvature. The effects of cycloplegia on refraction and corneal biometrics should be considered before cataract and refractive surgeries. |
Audience | Academic |
Author | Bagheri, Abbas Feizi, Mohadeseh Yazdani, Shahin Tavakoli, Mehdi Shafii, Aliakbar Faramarzi, Amir |
AuthorAffiliation | 1 Ocular Tissue Engineering Research Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran 2 Ophthalmic Research Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran |
AuthorAffiliation_xml | – name: 2 Ophthalmic Research Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran – name: 1 Ocular Tissue Engineering Research Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran |
Author_xml | – sequence: 1 givenname: Abbas surname: Bagheri fullname: Bagheri, Abbas organization: Ocular Tissue Engineering Research Center, Shahid Beheshti University of Medical Sciences; Ophthalmic Research Center, Shahid Beheshti University of Medical Sciences, Tehran – sequence: 2 givenname: Mohadeseh surname: Feizi fullname: Feizi, Mohadeseh organization: Ophthalmic Research Center, Shahid Beheshti University of Medical Sciences, Tehran – sequence: 3 givenname: Aliakbar surname: Shafii fullname: Shafii, Aliakbar organization: Ophthalmic Research Center, Shahid Beheshti University of Medical Sciences, Tehran – sequence: 4 givenname: Amir surname: Faramarzi fullname: Faramarzi, Amir organization: Ophthalmic Research Center, Shahid Beheshti University of Medical Sciences, Tehran – sequence: 5 givenname: Mehdi surname: Tavakoli fullname: Tavakoli, Mehdi organization: Ophthalmic Research Center, Shahid Beheshti University of Medical Sciences, Tehran – sequence: 6 givenname: Shahin surname: Yazdani fullname: Yazdani, Shahin organization: Ocular Tissue Engineering Research Center, Shahid Beheshti University of Medical Sciences; Ophthalmic Research Center, Shahid Beheshti University of Medical Sciences, Tehran |
BackLink | https://www.ncbi.nlm.nih.gov/pubmed/29719636$$D View this record in MEDLINE/PubMed |
BookMark | eNp9Uk1vEzEQXaEi-gF3TmglLlwS_LH22hdEVRVaKRIXkLhZ3lk7OHXsYO8m6r_HadIqqQBZsq2Z955nPO-8OgkxmKp6i9G0wYh-XMR1mm43hSVXuH1RnRGExIQS8vPk4H5anee8QIhz3ohX1SmRbSFQflZ9vrbWwFBHW8M9-LjyZu50HUMNMQWjfd25uDRDcpBrHfo6GZs0DG5t6jzowbyuXlrts3mzPy-qH1-uv1_dTGbfvt5eXc4mwAk3k5Zz2dtGWI5wA9IiSVEjus4Kzqzl0AsqLcYW9z3SwjYddG3HtLaUWyCmoxfV7U63j3qhVsktdbpXUTv1EIhprnQaHHijrGaUAwPMO9xYCsL2LUMYWCskFowXrU87rdXYLU0PJgxJ-yPR40xwv9Q8rhWTiFGEi8CHvUCKv0eTB7V0GYz3Opg4ZkUQbYgkXNICff8MuohjCuWrCoowTljbHqDmujTggo3lXdiKqktGG4kEa5uCmv4FVVZvlg6KNawr8SPCu8NGnzp8nH8B8B0AUsy5zFaBK1N1cdu38wojtTWaevDYgdEKET0jPmr_hzLbUTbRDyblOz9uTFKlrrsQN__klQRWO5eqWOrbu5T-AUAz9BU |
CitedBy_id | crossref_primary_10_1186_s12886_020_01594_8 crossref_primary_10_1016_j_optom_2020_04_001 crossref_primary_10_1038_s41598_022_25462_1 crossref_primary_10_1186_s12886_023_02840_5 crossref_primary_10_1177_25158414231180984 crossref_primary_10_1097_MD_0000000000038143 crossref_primary_10_3390_vision8030051 crossref_primary_10_1089_jop_2023_0039 crossref_primary_10_1167_jov_24_3_4 crossref_primary_10_1080_02713683_2021_1971720 crossref_primary_10_1186_s12886_021_01884_9 crossref_primary_10_1155_2021_8810782 crossref_primary_10_21673_anadoluklin_1407238 crossref_primary_10_1007_s00417_024_06658_9 |
ContentType | Journal Article |
Copyright | COPYRIGHT 2018 Medknow Publications and Media Pvt. Ltd. Copyright Medknow Publications & Media Pvt. Ltd. Apr/Jun 2018 Copyright: © 2018 Journal of Ophthalmic and Vision Research 2018 |
Copyright_xml | – notice: COPYRIGHT 2018 Medknow Publications and Media Pvt. Ltd. – notice: Copyright Medknow Publications & Media Pvt. Ltd. Apr/Jun 2018 – notice: Copyright: © 2018 Journal of Ophthalmic and Vision Research 2018 |
DBID | AAYXX CITATION NPM 3V. 7X7 7XB 8FI 8FJ 8FK ABUWG AFKRA AZQEC BENPR CCPQU DWQXO FYUFA GHDGH K9. M0S PHGZM PHGZT PIMPY PKEHL PQEST PQQKQ PQUKI PRINS 7X8 5PM DOA |
DOI | 10.4103/jovr.jovr_196_17 |
DatabaseName | CrossRef PubMed ProQuest Central (Corporate) ProQuest Health & Medical Collection (NC LIVE) ProQuest Central (purchase pre-March 2016) Hospital Premium Collection Hospital Premium Collection (Alumni Edition) ProQuest Central (Alumni) (purchase pre-March 2016) ProQuest Central (Alumni) ProQuest Central UK/Ireland ProQuest Central Essentials ProQuest Central ProQuest One Community College ProQuest Central Korea Health Research Premium Collection Health Research Premium Collection (Alumni) ProQuest Health & Medical Complete (Alumni) ProQuest Health & Medical Collection ProQuest Central Premium ProQuest One Academic Publicly Available Content Database ProQuest One Academic Middle East (New) ProQuest One Academic Eastern Edition (DO NOT USE) ProQuest One Academic ProQuest One Academic UKI Edition ProQuest Central China MEDLINE - Academic PubMed Central (Full Participant titles) DOAJ Directory of Open Access Journals |
DatabaseTitle | CrossRef PubMed Publicly Available Content Database ProQuest One Academic Middle East (New) ProQuest Central Essentials ProQuest One Academic Eastern Edition ProQuest Health & Medical Complete (Alumni) ProQuest Central (Alumni Edition) ProQuest One Community College ProQuest Hospital Collection Health Research Premium Collection (Alumni) ProQuest Central China ProQuest Hospital Collection (Alumni) ProQuest Central ProQuest Health & Medical Complete Health Research Premium Collection ProQuest One Academic UKI Edition Health and Medicine Complete (Alumni Edition) ProQuest Central Korea ProQuest Central (New) ProQuest One Academic ProQuest One Academic (New) ProQuest Central (Alumni) MEDLINE - Academic |
DatabaseTitleList | Publicly Available Content Database MEDLINE - Academic PubMed |
Database_xml | – sequence: 1 dbid: DOA name: DOAJ Directory of Open Access Journals url: https://www.doaj.org/ sourceTypes: Open Website – sequence: 2 dbid: NPM name: PubMed url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed sourceTypes: Index Database – sequence: 3 dbid: 7X7 name: ProQuest Health & Medical Collection (NC LIVE) url: https://search.proquest.com/healthcomplete sourceTypes: Aggregation Database |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Medicine |
EISSN | 2008-322X |
EndPage | 109 |
ExternalDocumentID | oai_doaj_org_article_fa536c5c16b14f3c8fd7501c57891856 PMC5905301 A534908574 29719636 10_4103_jovr_jovr_196_17 10.4103/jovr.jovr_196_17_101_Effect of cyclople |
Genre | Journal Article |
GroupedDBID | 04C 29L 2WC 5VS 7X7 8FI 8FJ 8R4 8R5 AAFWJ AAWTL ABUWG ACGFS ADBBV ADFRT ADRAZ AFKRA AFPKN AHMBA ALIPV ALMA_UNASSIGNED_HOLDINGS AOIJS BAWUL BCNDV BENPR BMSDO BPHCQ BVXVI CCPQU DIK DYU E3Z EIHBH EJD EOJEC FYUFA GROUPED_DOAJ GX1 H13 HMCUK HYE IAO IHR IPNFZ ITC KQ8 KWQ M48 OBODZ OK1 PGMZT PHGZM PHGZT PIMPY PQQKQ PROAC Q2X RIG RNS RPM TR2 UKHRP AAYXX CITATION C~G 3V. ABXLX IHW M~E NPM PMFND 7XB 8FK AZQEC DWQXO K9. PKEHL PQEST PQUKI PRINS 7X8 5PM PUEGO |
ID | FETCH-LOGICAL-c626e-7669df48f6014c9f093048bbf865ff6cd839f11f1dd0a8f4bcb7b5aaf36fc2eb3 |
IEDL.DBID | M48 |
ISSN | 2008-322X 2008-2010 |
IngestDate | Wed Aug 27 01:22:07 EDT 2025 Thu Aug 21 14:31:29 EDT 2025 Thu Jul 10 18:13:23 EDT 2025 Mon Jun 30 14:04:58 EDT 2025 Tue Jun 17 21:05:57 EDT 2025 Tue Jun 10 20:35:08 EDT 2025 Thu Jan 02 22:55:04 EST 2025 Tue Jul 01 00:56:24 EDT 2025 Thu Apr 24 22:51:11 EDT 2025 Tue Jun 17 22:45:54 EDT 2025 |
IsDoiOpenAccess | true |
IsOpenAccess | true |
IsPeerReviewed | true |
IsScholarly | true |
Issue | 2 |
Keywords | Corneal Thickness Corneal Curvature Cycloplegia Refraction Astigmatism |
Language | English |
License | http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
LinkModel | DirectLink |
MergedId | FETCHMERGED-LOGICAL-c626e-7669df48f6014c9f093048bbf865ff6cd839f11f1dd0a8f4bcb7b5aaf36fc2eb3 |
Notes | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 14 content type line 23 |
OpenAccessLink | http://journals.scholarsportal.info/openUrl.xqy?doi=10.4103/jovr.jovr_196_17 |
PMID | 29719636 |
PQID | 2025625773 |
PQPubID | 54735 |
PageCount | 9 |
ParticipantIDs | doaj_primary_oai_doaj_org_article_fa536c5c16b14f3c8fd7501c57891856 pubmedcentral_primary_oai_pubmedcentral_nih_gov_5905301 proquest_miscellaneous_2034292693 proquest_journals_2025625773 gale_infotracmisc_A534908574 gale_infotracacademiconefile_A534908574 pubmed_primary_29719636 crossref_citationtrail_10_4103_jovr_jovr_196_17 crossref_primary_10_4103_jovr_jovr_196_17 wolterskluwer_medknow_10_4103_jovr_jovr_196_17_101_Effect_of_cyclople |
ProviderPackageCode | CITATION AAYXX |
PublicationCentury | 2000 |
PublicationDate | 20180401 |
PublicationDateYYYYMMDD | 2018-04-01 |
PublicationDate_xml | – month: 4 year: 2018 text: 20180401 day: 01 |
PublicationDecade | 2010 |
PublicationPlace | India |
PublicationPlace_xml | – name: India – name: Mumbai |
PublicationTitle | Journal of ophthalmic & vision research |
PublicationTitleAlternate | J Ophthalmic Vis Res |
PublicationYear | 2018 |
Publisher | Wolters Kluwer India Pvt. Ltd Medknow Publications and Media Pvt. Ltd Medknow Publications & Media Pvt. Ltd Medknow Publications & Media Pvt Ltd Knowledge E |
Publisher_xml | – name: Wolters Kluwer India Pvt. Ltd – name: Medknow Publications and Media Pvt. Ltd – name: Medknow Publications & Media Pvt. Ltd – name: Medknow Publications & Media Pvt Ltd – name: Knowledge E |
References | Ni (key-10.4103/2008-322X.229646-4) 2013 Read (key-10.4103/2008-322X.229646-10) 2007 Fan (key-10.4103/2008-322X.229646-31) 2004 Dobrowolsky (key-10.4103/2008-322X.229646-33) 1868 Gao (key-10.4103/2008-322X.229646-16) 2002 Gao (key-10.4103/2008-322X.229646-41) 2006 Bannon (key-10.4103/2008-322X.229646-38) 1946 Pierścionek (key-10.4103/2008-322X.229646-7) 2001 Wang (key-10.4103/2008-322X.229646-24) 2011 Brzezinski (key-10.4103/2008-322X.229646-34) 1982 Chen (key-10.4103/2008-322X.229646-42) 2011 Naylor (key-10.4103/2008-322X.229646-27) 1968 Sisó-Fuertes (key-10.4103/2008-322X.229646-3) 2015 Ukai (key-10.4103/2008-322X.229646-32) 1991 Buehren (key-10.4103/2008-322X.229646-6) 2003 Sergienko (key-10.4103/2008-322X.229646-13) 2008 Nakazawa (key-10.4103/2008-322X.229646-14) 1983 Ott (key-10.4103/2008-322X.229646-15) 2006 Palamar (key-10.4103/2008-322X.229646-35) 2011 Bayramlar (key-10.4103/2008-322X.229646-5) 2013 Farhood (key-10.4103/2008-322X.229646-22) 2012 Rodriguez-Raton (key-10.4103/2008-322X.229646-18) 2015 Young (key-10.4103/2008-322X.229646-39) 1801 He (key-10.4103/2008-322X.229646-9) 2003 Saitoh (key-10.4103/2008-322X.229646-21) 2004 Millodot (key-10.4103/2008-322X.229646-37) 1985 Dubbelman (key-10.4103/2008-322X.229646-1) 2005 Thibos (key-10.4103/2008-322X.229646-26) 1997 Schachar (key-10.4103/2008-322X.229646-40) 2006 Chang (key-10.4103/2008-322X.229646-17) 2016 Baldwin (key-10.4103/2008-322X.229646-12) 1981 Grosvenor (key-10.4103/2008-322X.229646-11) 1998 Holladay (key-10.4103/2008-322X.229646-25) 1992 Hiraoka (key-10.4103/2008-322X.229646-30) 2013 Salouti (key-10.4103/2008-322X.229646-29) 2009 Bolz (key-10.4103/2008-322X.229646-2) 2007 Cheng (key-10.4103/2008-322X.229646-19) 2014 Aramberri (key-10.4103/2008-322X.229646-28) 2012 Carkeet (key-10.4103/2008-322X.229646-36) 2003 Bagheri (key-10.4103/2008-322X.229646-23) 2007 Crawford (key-10.4103/2008-322X.229646-20) 2013 Yasuda (key-10.4103/2008-322X.229646-8) 2003 |
References_xml | – start-page: 1251 volume-title: Effect of accommodation on corneal topography year: 2013 ident: key-10.4103/2008-322X.229646-5 publication-title: Cornea – start-page: 1297 volume-title: Changes in corneal curvature in accommodation year: 2003 ident: key-10.4103/2008-322X.229646-8 publication-title: J Cataract Refract Surg – start-page: 309 volume-title: Effect of pupil dilation on biometry measurements with partial coherence interferometry and its effect on IOL power formula calculation year: 2015 ident: key-10.4103/2008-322X.229646-18 publication-title: Eur J Ophthalmol – start-page: 5 volume-title: Review: Astigmatic Accommodation (Sectional Accommodation) – A form of Dynamic Astigmatism year: 1982 ident: key-10.4103/2008-322X.229646-34 publication-title: Clin Exp Optom – start-page: 360 volume-title: Linear relationship of refractive and biometric lenticular changes during accommodation in emmetropic and myopic eyes year: 2007 ident: key-10.4103/2008-322X.229646-2 publication-title: Br J Ophthalmol – start-page: e26103 volume-title: Corneal alternations induced by topical application of benzalkonium chloride in rabbit year: 2011 ident: key-10.4103/2008-322X.229646-42 publication-title: PLoS One – start-page: 244 volume-title: Evaluation of corneal changes with accommodation in young and presbyopic populations using Pentacam High Resolution Scheimpflug system year: 2013 ident: key-10.4103/2008-322X.229646-4 publication-title: Clin Exp Ophthalmol – start-page: 435 volume-title: Apparent accommodation in pseudophakic eyes after implantation of posterior chamber intraocular lenses year: 1983 ident: key-10.4103/2008-322X.229646-14 publication-title: Am J Ophthalmol – start-page: 294 volume-title: Optimal dosage of cyclopentolate 1% for complete cycloplegia: A randomized clinical trial year: 2007 ident: key-10.4103/2008-322X.229646-23 publication-title: Eur J Ophthalmol – start-page: 53 volume-title: A study of astigmatism at the near point with special reference to astigmatic accommodation year: 1946 ident: key-10.4103/2008-322X.229646-38 publication-title: Am J Optom Arch Am Acad Optom – start-page: 297 volume-title: Variation of astigmatism with accommodation and its relationship with dark focus year: 1985 ident: key-10.4103/2008-322X.229646-37 publication-title: Ophthalmic Physiol Opt – start-page: 1716 volume-title: Total corneal power estimation: Ray tracing method versus gaussian optics formula year: 2011 ident: key-10.4103/2008-322X.229646-24 publication-title: Invest Ophthalmol Vis Sci – start-page: e461 volume-title: Influences of cyclopentolate hydrochloride on anterior segment parameters with Pentacam in children year: 2011 ident: key-10.4103/2008-322X.229646-35 publication-title: Acta Ophthalmol – start-page: 293 volume-title: The change in ocular refractive components after cycloplegia in children year: 2002 ident: key-10.4103/2008-322X.229646-16 publication-title: Jpn J Ophthalmol – start-page: 311 volume-title: Corneal topography and accommodation year: 2003 ident: key-10.4103/2008-322X.229646-6 publication-title: Cornea – start-page: 316 volume-title: Higher order ocular aberrations after cycloplegic and non-cycloplegic pupil dilation year: 2003 ident: key-10.4103/2008-322X.229646-36 publication-title: J Refract Surg – start-page: 813 volume-title: Changes in ocular astigmatism over the whole range of accommodation year: 1991 ident: key-10.4103/2008-322X.229646-32 publication-title: Optom Vis Sci – start-page: 1113 volume-title: Short-term refractive change and ocular parameter changes after cycloplegia year: 2014 ident: key-10.4103/2008-322X.229646-19 publication-title: Optom Vis Sci – start-page: 422 volume-title: Astigmatic difference in refractive errors year: 1968 ident: key-10.4103/2008-322X.229646-27 publication-title: Br J Ophthalmol – start-page: 23 volume-title: On the mechanics of eye year: 1801 ident: key-10.4103/2008-322X.229646-39 publication-title: Phil Trans R Soc Lond – start-page: 97 volume-title: Visual accommodation in vertebrates: Mechanisms, physiological response and stimuli year: 2006 ident: key-10.4103/2008-322X.229646-15 publication-title: J Comp Physiol A Neuroethol Sens Neural Behav Physiol – start-page: 117 volume-title: Change in shape of the aging human crystalline lens with accommodation year: 2005 ident: key-10.4103/2008-322X.229646-1 publication-title: Vision Res – start-page: 462 volume-title: Comparative study on the safety and efficacy of different cycloplegic agents in children with darkly pigmented irides year: 2004 ident: key-10.4103/2008-322X.229646-31 publication-title: Clin Exp Ophthalmol – start-page: 981 volume-title: Corneal changes with accommodation using dual Scheimpflug photography year: 2015 ident: key-10.4103/2008-322X.229646-3 publication-title: J Cataract Refract Surg – start-page: 404 volume-title: The effects of eye drops on corneal thickness in adult myopia year: 2006 ident: key-10.4103/2008-322X.229646-41 publication-title: Cornea – start-page: 39 volume-title: The mechanism of accommodation and presbyopia year: 2006 ident: key-10.4103/2008-322X.229646-40 publication-title: Int Ophthalmol Clin – start-page: 53 volume-title: Comparison and repeatability of keratometric and corneal power measurements obtained by Orbscan II, Pentacam, and Galilei corneal tomography systems year: 2013 ident: key-10.4103/2008-322X.229646-20 publication-title: Am J Ophthalmol – start-page: 1934 volume-title: Dual versus single Scheimpflug camera for anterior segment analysis: Precision and agreement year: 2012 ident: key-10.4103/2008-322X.229646-28 publication-title: J Cataract Refract Surg – start-page: 1877 volume-title: Influence of accommodation on the anterior and posterior cornea year: 2007 ident: key-10.4103/2008-322X.229646-10 publication-title: J Cataract Refract Surg – start-page: 8 volume-title: Influences of cycloplegia with topical atropine on ocular higher-order aberrations year: 2013 ident: key-10.4103/2008-322X.229646-30 publication-title: Ophthalmology – start-page: 239 volume-title: Cycloplegic Refraction in Children with Cyclopentolate versus Atropine year: 2012 ident: key-10.4103/2008-322X.229646-22 publication-title: J Clin Exp Ophthalmol – start-page: 51 volume-title: Veberverschiedene Weanderungendes Astigmatismus Unterdem Einfluss Accomodation year: 1868 ident: key-10.4103/2008-322X.229646-33 publication-title: W Aech F Ophth – start-page: 132 volume-title: Role of the cornea in emmetropia and myopia year: 1998 ident: key-10.4103/2008-322X.229646-11 publication-title: Optom Vis Sci – start-page: 456 volume-title: Change in corneal shape and corneal wave-front aberrations with accommodation year: 2003 ident: key-10.4103/2008-322X.229646-9 publication-title: J Vis – start-page: 1623 volume-title: Depth of focus in pseudophakic eyes year: 2008 ident: key-10.4103/2008-322X.229646-13 publication-title: Graefes Arch Clin Exp Ophthalmol – start-page: 1024 volume-title: Changes in the shape of the anterior and posterior corneal surfaces caused by mydriasis and miosis: Detailed analysis year: 2004 ident: key-10.4103/2008-322X.229646-21 publication-title: J Cataract Refract Surg – start-page: 429 volume-title: Calculating the surgically induced refractive change following ocular surgery year: 1992 ident: key-10.4103/2008-322X.229646-25 publication-title: J Cataract Refract Surg – start-page: 367 volume-title: Power vectors: An application of Fourier analysis to the description and statistical analysis of refractive error year: 1997 ident: key-10.4103/2008-322X.229646-26 publication-title: Optom Vis Sci – start-page: 856 volume-title: Comparison of anterior elevation map measurements between 2 Scheimpflug imaging systems year: 2009 ident: key-10.4103/2008-322X.229646-29 publication-title: J Cataract Refract Surg – start-page: 766 volume-title: Corneal shape change during accommodation year: 2001 ident: key-10.4103/2008-322X.229646-7 publication-title: Eye (Lond) – start-page: 12 volume-title: Anterior Segment Biometry Changes with Cycloplegia in Myopic Adults year: 2016 ident: key-10.4103/2008-322X.229646-17 publication-title: Optom Vis Sci – start-page: 206 volume-title: A longitudinal study of corneal astigmatism and total astigmatism year: 1981 ident: key-10.4103/2008-322X.229646-12 publication-title: Am J Optom Physiol Opt |
SSID | ssj0066648 |
Score | 2.166646 |
Snippet | Purpose: To determine changes in refractive state and corneal parameters after cycloplegia with cyclopentolate hydrochloride 1% using a dual Scheimpflug... To determine changes in refractive state and corneal parameters after cycloplegia with cyclopentolate hydrochloride 1% using a dual Scheimpflug imaging system.... To determine changes in refractive state and corneal parameters after cycloplegia with cyclopentolate hydrochloride 1% using a dual Scheimpflug imaging... |
SourceID | doaj pubmedcentral proquest gale pubmed crossref wolterskluwer |
SourceType | Open Website Open Access Repository Aggregation Database Index Database Enrichment Source Publisher |
StartPage | 101 |
SubjectTerms | Analysis Astigmatism; Corneal Curvature; Corneal Thickness; Cycloplegia; Refraction Biometrics Cataracts Causes of Cross-sectional studies Dosage and administration Engineering research Imaging systems Medical imaging Ophthalmic agents Original Paralysis Research centers Statistical analysis Tissue engineering |
SummonAdditionalLinks | – databaseName: DOAJ Directory of Open Access Journals dbid: DOA link: http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwrV3NaxUxEA_SgwgifrtaJYIgHta3u_m-WaWlCHqy8G4hySZaW3elr6343zuT7Hu-VdSLl3d4mYVk8pvMDPNFyLOgfOx6ocEtAfONN9rVnrFUO3A9usiiciFnW7yXh0f87VIst0Z9YU5YaQ9cGLdITjAZRGilb3liQacelFwbAGkGdE1utg06b-1MlTcYbPI8NysH9wGyyxKg5G3DFp_Hy7OX-GMBfDYPKvupkHLf_t9f5y319Gvq5PVvI4a1Vyc5q31LNx3cJDcmo5LulcPcIlficJtcfTeFze-QV6VHMR0TDd_DKeaMfzx2dBwo-J4DmIo0V-Fjs_4VdUNPYZe5euoy0lxxdJccHex_eHNYT6MT6gAeSqyVlKZPXCfwt3gwqTEMRNX7pKVISYYe7KLUtqnt-8bpxH3wygvnEpMpdOBg3yM7wzjEB4QazWLDk5CRg7XleqOl110fVZe4kyFWZLHmnw1TX3Ecb3Fqwb9AjtvM7C2OV-TF5ouvpafGX2hf45Vs6LAbdv4DMGInjNh_YaQiz_FCLcosbC24qfQADojdr-yeYBj_FIpXZHdGCbIW5strSNhJ1le2Q7MRXj7FKvJ0s4xfYv7aEMcLpGE4F0waoLlfELQ5UmcUPoOwSzXD1uzM85Xh-FPuBC4MvKFNW5H9GQrtl1JK-UeuYmKfLdCzI1zbBL2H_4PZj8g1MCp1yW7aJTvnZxfxMRhu5_5JltEfpmFDug priority: 102 providerName: Directory of Open Access Journals – databaseName: ProQuest Health & Medical Collection (NC LIVE) dbid: 7X7 link: http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwfV3Nb9UwDI9gSAhpQnyvMFCQkBCHsrZJk_QEA22akODEpHeL8rkNRjve24b477HTvLdXELv00LhS4vzs2LVjE_LKSRsa3ypwS8B845UypWUslgZcjyawII1L2RZfxMEh_zRrZ_mH2yKnVS51YlLUfnD4jxyddLTVpWTvzn6W2DUKo6u5hcZNcgtLlyGq5WzlcIFlnrpnpRA_Rn3HMCWvK7bzbbicv8WHBgjq1K7s6lhK1fv_1dFrh9TfCZSbvwYMbi--p9z2tRNq_x65m01Lujti4T65EfoH5PbnHDx_SN6PlYrpEKn77U4xc_zoxNChp-CB9mAw0nQXH0v2L6jpPYVZpjtUl4Gme0ePyOH-3tePB2VuoFA68FNCKYXofOQqgtfFXRerjoHAWhuVaGMUzoN1FOs61t5XRkVunZW2NSYyEV0DbvZjstEPfdgitFMsVDy2InCwuYzvlLCq8UE2kRvhQkF2lvzTLlcXxyYXpxq8DOS4Tsxe43hB3qy-OBsra1xD-wG3ZEWHNbHTi2F-pLOI6WhaJlzramFrHplT0YM5VDvQSR1YJaIgr3FDNUouTM2ZfAEBFog1sPRuyzAK2kpekO0JJUicmw4vIaGzxC_0FT4L8nI1jF9iFlsfhgukYdgdTHRA82RE0GpJTSdRGcIs5QRbkzVPR_qT41QPvO1Ak1Z1QfYmKNQ_xguV_-UqpvfpEXp6gG3L0Ht6_fKekTsgS2rMXtomG-fzi_AcDLNz-yJJ3x8q5jue priority: 102 providerName: ProQuest |
Title | Effect of cycloplegia on corneal biometrics and refractive state |
URI | http://www.jovr.org/article.asp?issn=2008-322X;year=2018;volume=13;issue=2;spage=101;epage=109;aulast=Bagheri;type=0 https://www.ncbi.nlm.nih.gov/pubmed/29719636 https://www.proquest.com/docview/2025625773 https://www.proquest.com/docview/2034292693 https://pubmed.ncbi.nlm.nih.gov/PMC5905301 https://doaj.org/article/fa536c5c16b14f3c8fd7501c57891856 |
Volume | 13 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV3fb9MwED6xTUJICPGbwKiChIR4aElix06eYK06TUib0ESl8mQ5jr1NlATSbbD_njsnLQ0MHnjJQ21X8fk7-7vc-Q7gpZGFTco0Q7ME6RuPMj0sGHNDjaZHYpmV2vhoiyNxMOPv5-n81_XoToDLa007qic1axajH9-u3qLCI38d8ThiOOiyGdFDIZxULLdgB88lSfUMDvnap4A83dfS8g5_8gG3Tstr_4FSBOeSwCl655VP6__n5r1xev0eWXn7e01e7-VnH_S-cXTt34U7HecM91qQ3IMbtroPNw87r_oDeNemMA5rF06uzIJCyk_OdFhX4aRuKmSS4Zgu6VMu_2WoqzI8ts5frrq0oSerD2G2P_04ORh2lRWGBg0YO5RC5KXjmUNzjJvcRTlDTS4Kl4nUOWFKpE0ujl1clpHOHC9MIYtUa8eEMwna349gu6or-wTCPGM24i4VliMZ02WeiSJLSisTx7UwNoA3K_kp06Udp-oXC4XmBwlfeblvCD-A1-sRX9uUG__oO6YlWfejZNn-h7o5UZ3uKadTJkxqYlHE3DGTuRJ5Umxws8qRrogAXtGCKgIZvprR3c0EnCAlx1J7KSP3aCp5ALu9nqiKpt-8goRaIVklxCpxY5QsgBfrZhpJ4W2VrS-oD6OyYSLHPo9bBK2ntAJiALKHrd6c-y3V2alPFJ7muMVGcQDTHgrVl_am5V-lSnF_qoWeqnHZOug9_e83eAa3UOOyNuJpF7bPmwv7HMnceTGALTmXA9gZT48-HA_8JxF6fpoNvPb-BKmXUa0 |
linkProvider | Scholars Portal |
linkToHtml | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwtV1Lb9QwELZKkQAJId4EChgJhDiEJrFjJwcEBVpt6ePUSnszjh-lUJKy24f6p_iNzDjZdAOit15yWDuRPZ4Zz7fzIuSlkZXLbF4ALAHzjSeFjivGfKwBemSOOalNiLbYFqNd_mWcjxfI71kuDIZVznRiUNS2MfgfOYJ0tNWlZO8Pf8XYNQq9q7MWGi1bbLizU4Bs03frn-F8X2XZ2urOp1HcdRWIDRjvLpZClNbzwgMU4ab0AOmBi6vKFyL3XhgLJoNPU59am-jC88pUssq19kx4kwH2hO9eIVfh4k0Q7MlxD_AACYRuXSGkAL3MrVuUpwlb_t6cTN7iQwHLq9Ae7fwaDN0C_r0T5i7FvwM2b5426Eyf_gix9HM34tptcqszZelKy3t3yIKr75JrW52z_h750FZGpo2n5swcYKT63r6mTU0B8dZgoNKQ-48tAqZU15bCKkPO1omjIc_pPtm9FNI-IIt1U7tHhJYFcwn3uXAcbDxty0JURWadzDzXwriILM_op0xXzRybahwoQDVIcRWIPUfxiLzp3zhsK3lcMPcjHkk_D2twhx-ayZ7qRFp5nTNhcpOKKuWemcJbML9SAzqwBCtIROQ1HqhCTQFLM7pLeIANYs0ttZIz9LrmkkdkaTATJNwMh2csoToNM1Xn8hCRF_0wvolRc7VrjnEOw25kooQ5D1sO6reUlRKVL6xSDnhrsOfhSL3_LdQfz0vQ3EkakdUBF6qfbQLnf6mK4YSqZT3VwLF1rPf44u09J9dHO1ubanN9e-MJuQFyVbSRU0tk8Why7J6CUXhUPQuSSMnXyxb9P_V4eis |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Effect+of+Cycloplegia+on+Corneal+Biometrics+and+Refractive+State&rft.jtitle=Journal+of+ophthalmic+%26+vision+research&rft.au=Bagheri%2C+Abbas&rft.au=Feizi%2C+Mohadeseh&rft.au=Shafii%2C+Aliakbar&rft.au=Faramarzi%2C+Amir&rft.date=2018-04-01&rft.pub=Medknow+Publications+%26+Media+Pvt+Ltd&rft.issn=2008-2010&rft.eissn=2008-322X&rft.volume=13&rft.issue=2&rft.spage=101&rft.epage=109&rft_id=info:doi/10.4103%2Fjovr.jovr_196_17&rft_id=info%3Apmid%2F29719636&rft.externalDocID=PMC5905301 |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=2008-322X&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=2008-322X&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=2008-322X&client=summon |