Pathological findings after third- and second-generation everolimus-eluting stent implantations in coronary arteries from autopsy cases and an atherosclerotic porcine model

Pathological changes after third-generation drug-eluting stent implantation remain unclear. We compared the tissue responses of coronary arteries after the implantation of third-generation abluminal biodegradable-polymer everolimus-eluting stent (3rd EES) and second-generation durable-polymer EES (2...

Full description

Saved in:
Bibliographic Details
Published inScientific reports Vol. 11; no. 1; p. 6281
Main Authors Migita, Suguru, Kitano, Daisuke, Li, Yuxin, Koyama, Yutaka, Shimodai-Yamada, Sayaka, Onishi, Akira, Fuchimoto, Daiichiro, Suzuki, Shunichi, Nakamura, Yoshiyuki, Matsuyama, Taka-aki, Hirota, Seiichi, Sakuma, Masashi, Tsujimoto, Masahiko, Hirayama, Atsushi, Okumura, Yasuo, Hao, Hiroyuki
Format Journal Article
LanguageEnglish
Published London Nature Publishing Group UK 18.03.2021
Nature Publishing Group
Nature Portfolio
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Pathological changes after third-generation drug-eluting stent implantation remain unclear. We compared the tissue responses of coronary arteries after the implantation of third-generation abluminal biodegradable-polymer everolimus-eluting stent (3rd EES) and second-generation durable-polymer EES (2nd EES) using autopsy specimens and an atherosclerotic porcine model. We compared the histology of stented coronary arteries obtained by autopsy performed 1–10 months after 3rd EES (n (number of cases) = 4, stent-implanted period of 3–7 months) and 2nd EES (n (number of cases) = 9, stent-implanted period of 1–10 months) implantations. The ratio of covered stent struts was higher with 3rd EESs than with 2nd EESs (3rd; 0.824 ± 0.032 vs. 2nd; 0.736 ± 0.022, p  = 0.035). Low-density lipoprotein receptor knockout minipigs were stented with 3rd or 2nd EES in the coronary arteries and the stented regions were investigated. The fibrin deposition around the 2nd EES was more prominent. Additionally, higher density of smooth muscle cells was confirmed after the 3rd EES implantation. Pathological examination after the 3rd EES demonstrated a combination of less fibrin deposition and more rapid acquisition of well-developed neointima as compared to the 2nd EES at autopsy and the atherosclerotic porcine model.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:2045-2322
2045-2322
DOI:10.1038/s41598-021-85740-2