高压带电设备电压等级非接触识别方法研究
现有的接触式验电需分电压等级使用不同的验电设备,非接触式验则无法识别电压等级,而电压等级直接决定了带电作业安全距离。电压等级的非接触识别对验电设备的非接触验电、近电预警有重要意义。文章基于距离和电场测量,利用多项式回归分析理论研究了一种电压等级的非接触识别方法。通过采集10kV、35kV和110kV三种电压等级周围的电场和距离数据,分别求取三种拟合函数,进行多项式回归分析,从而实现电压等级的判别。同时研制了电压等级非接触识别装置,对该方法进行识别验证,实验结果证明能够对三种电压等级实现较好地识别。...
Saved in:
Published in | 电测与仪表 Vol. 54; no. 24; pp. 37 - 41 |
---|---|
Main Author | |
Format | Journal Article |
Language | Chinese |
Published |
云南电网有限责任公司电力科学研究院,昆明,650217%云南电网有限责任公司,昆明,650000
2017
|
Subjects | |
Online Access | Get full text |
ISSN | 1001-1390 |
DOI | 10.3969/j.issn.1001-1390.2017.24.006 |
Cover
Abstract | 现有的接触式验电需分电压等级使用不同的验电设备,非接触式验则无法识别电压等级,而电压等级直接决定了带电作业安全距离。电压等级的非接触识别对验电设备的非接触验电、近电预警有重要意义。文章基于距离和电场测量,利用多项式回归分析理论研究了一种电压等级的非接触识别方法。通过采集10kV、35kV和110kV三种电压等级周围的电场和距离数据,分别求取三种拟合函数,进行多项式回归分析,从而实现电压等级的判别。同时研制了电压等级非接触识别装置,对该方法进行识别验证,实验结果证明能够对三种电压等级实现较好地识别。 |
---|---|
AbstractList | TM769; 现有的接触式验电需分电压等级使用不同的验电设备,非接触式验则无法识别电压等级,而电压等级直接决定了带电作业安全距离.电压等级的非接触识别对验电设备的非接触验电、近电预警有重要意义.文章基于距离和电场测量,利用多项式回归分析理论研究了一种电压等级的非接触识别方法.通过采集10 kV、35kV和110 kV三种电压等级周围的电场和距离数据,分别求取三种拟合函数,进行多项式回归分析,从而实现电压等级的判别.同时研制了电压等级非接触识别装置,对该方法进行识别验证,实验结果证明能够对三种电压等级实现较好地识别. 现有的接触式验电需分电压等级使用不同的验电设备,非接触式验则无法识别电压等级,而电压等级直接决定了带电作业安全距离。电压等级的非接触识别对验电设备的非接触验电、近电预警有重要意义。文章基于距离和电场测量,利用多项式回归分析理论研究了一种电压等级的非接触识别方法。通过采集10kV、35kV和110kV三种电压等级周围的电场和距离数据,分别求取三种拟合函数,进行多项式回归分析,从而实现电压等级的判别。同时研制了电压等级非接触识别装置,对该方法进行识别验证,实验结果证明能够对三种电压等级实现较好地识别。 |
Abstract_FL | The existing contact type inspection needs to be divided into voltage levels to use different inspection equipments,and the non-contact test can not identify the voltage level,and the voltage level directly determines the safe distance of live operation.Non-contact identification of voltage level is important to non-contact inspection and early warning of electric equipment.Based on the distance and measurement of electric field,a method of non-contact identification of voltage level is studied by using the theory of polynomial regression analysis.By collecting the electric field and distance data of 10 kV,35 kV and 110 kV,the three fitting functions are obtained respectively,and the polynomial regression analysis is carried out to realize the discrimination of the voltage grade of the three kinds of voltage.At the same time,a voltage level non-contact identification device is developed to identify and validate the proposed method.The experimental results show that the three voltage levels can be well recognized. |
Author | 唐立军;魏杰;周年荣;方正云;张林山 |
AuthorAffiliation | 云南电网有限责任公司电力科学研究院,昆明650217;云南电网有限责任公司,昆明650000 |
AuthorAffiliation_xml | – name: 云南电网有限责任公司电力科学研究院,昆明,650217%云南电网有限责任公司,昆明,650000 |
Author_FL | Tang Lijun Fang Zhengyun Zhang Linshan Zhou Nianrong Wei Jie |
Author_FL_xml | – sequence: 1 fullname: Tang Lijun – sequence: 2 fullname: Wei Jie – sequence: 3 fullname: Zhou Nianrong – sequence: 4 fullname: Fang Zhengyun – sequence: 5 fullname: Zhang Linshan |
Author_xml | – sequence: 1 fullname: 唐立军;魏杰;周年荣;方正云;张林山 |
BookMark | eNo9j71KA0EcxLeIYBJ9CRG7O_d_-11K8AsCNunD3d5uTNCN5hDJC_iBkCqKjWKhCRLUQhS18G0ul7yFJxGrGYYfM0wJFVzbGYSWAftEcbXa8ptJ4nzAGDwgCvsBBuEH1MeYF1DxP59HpSRpYUyUUFBEajq6TnsX6ccg679Nnr_T-9Pc5En2dJ59Dac3t-Pew2Q4mLycpGej8dXn-PUyu-tnj-8LaM6Ge4lZ_NMyqm2s1ypbXnVnc7uyVvU0k9wzjFLADAxnFuIYwFApY60pjaUFxriMBGdUGCWiyAZa4hAbLnlItBWWEVJGK7Pa49DZ0DXqrfZRx-WD9Vh3u9Hvy4DmH3NwaQbq3bZrHDZz9KDT3A873ToXFLgEysgPL4prQw |
ClassificationCodes | TM769 |
ContentType | Journal Article |
Copyright | Copyright © Wanfang Data Co. Ltd. All Rights Reserved. |
Copyright_xml | – notice: Copyright © Wanfang Data Co. Ltd. All Rights Reserved. |
DBID | 2RA 92L CQIGP W92 ~WA 2B. 4A8 92I 93N PSX TCJ |
DOI | 10.3969/j.issn.1001-1390.2017.24.006 |
DatabaseName | 维普期刊资源整合服务平台 中文科技期刊数据库-CALIS站点 中文科技期刊数据库-7.0平台 中文科技期刊数据库-工程技术 中文科技期刊数据库- 镜像站点 Wanfang Data Journals - Hong Kong WANFANG Data Centre Wanfang Data Journals 万方数据期刊 - 香港版 China Online Journals (COJ) China Online Journals (COJ) |
DatabaseTitleList | |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Engineering |
DocumentTitleAlternate | Research on voltage level non-contact identification method for high voltage live equipment |
DocumentTitle_FL | Research on voltage level non-contact identification method for high voltage live equipment |
EndPage | 41 |
ExternalDocumentID | dcyyb201724006 674168145 |
GrantInformation_xml | – fundername: 中国南方电网有限责任公司科研项目 funderid: (K-YN2014-186、YNKJXM00000293) |
GroupedDBID | -03 2B. 2C0 2RA 5XA 5XD 92H 92I 92L ACGFS ALMA_UNASSIGNED_HOLDINGS CCEZO CEKLB CQIGP CW9 TCJ TGT U1G U5M W92 ~WA 4A8 93N ABJNI ADMLS GROUPED_DOAJ PSX |
ID | FETCH-LOGICAL-c586-e5441051e65f1dd11e488dcc44d8f15568b76547e97bbf2c80a0e686a3cf7f533 |
ISSN | 1001-1390 |
IngestDate | Thu May 29 04:07:58 EDT 2025 Wed Feb 14 10:04:01 EST 2024 |
IsPeerReviewed | true |
IsScholarly | true |
Issue | 24 |
Keywords | power frequency electric field sensor 函数拟合 工频电场传感器 function fitting 电压等级识别 voltage level recognition 非接触测量 non-contact measurement |
Language | Chinese |
LinkModel | OpenURL |
MergedId | FETCHMERGED-LOGICAL-c586-e5441051e65f1dd11e488dcc44d8f15568b76547e97bbf2c80a0e686a3cf7f533 |
Notes | 23-1202/TH power frequency electric field sensor, voltage level recognition, non-contact measurement, function fitting The existing contact type inspection needs to be divided into voltage levels to use different inspection equip- ments, and the non-contact test can not identify the voltage level, and the voltage level directly determines the safe distance of live operation. Non-contact identification of voltage level is important to non-contact inspection and early warning of electric equipment. Based on the distance and measurement of electric field, a method of non-contact identification of voltage level is studied by using the theory of polynomial regression analysis. By collecting the electric field and distance data of 10 kV, 35 kV and 110 kV, the three fitting functions are obtained respectively, and the polynomial regression analysis is carried out to realize the discrimination of the voltage grade of the three kinds of voltage. At the same time, a voltage level non-contact identification device is deve |
PageCount | 5 |
ParticipantIDs | wanfang_journals_dcyyb201724006 chongqing_primary_674168145 |
PublicationCentury | 2000 |
PublicationDate | 2017 |
PublicationDateYYYYMMDD | 2017-01-01 |
PublicationDate_xml | – year: 2017 text: 2017 |
PublicationDecade | 2010 |
PublicationTitle | 电测与仪表 |
PublicationTitleAlternate | Electrical Measurement & Instrumentation |
PublicationTitle_FL | Electrical Measurement & Instrumentation |
PublicationYear | 2017 |
Publisher | 云南电网有限责任公司电力科学研究院,昆明,650217%云南电网有限责任公司,昆明,650000 |
Publisher_xml | – name: 云南电网有限责任公司电力科学研究院,昆明,650217%云南电网有限责任公司,昆明,650000 |
SSID | ssj0039791 ssib001129792 ssib051374602 ssib017479537 |
Score | 2.0608082 |
Snippet | ... TM769; 现有的接触式验电需分电压等级使用不同的验电设备,非接触式验则无法识别电压等级,而电压等级直接决定了带电作业安全距离.电压等级的非接触识别对验电设备的非接触验电、近电预警有重要意义.文章基于距离和电场测量,利用多项式回归分析理论研究了一种电压等级的非接触识别方法.通过采集10 kV、35kV和110... |
SourceID | wanfang chongqing |
SourceType | Aggregation Database Publisher |
StartPage | 37 |
SubjectTerms | 函数拟合 工频电场传感器 电压等级识别 非接触测量 |
Title | 高压带电设备电压等级非接触识别方法研究 |
URI | http://lib.cqvip.com/qk/92179X/201724/674168145.html https://d.wanfangdata.com.cn/periodical/dcyyb201724006 |
Volume | 54 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwtV1Lb9QwELZKkRAcEE9RCrSH-piSh-PH0e5mVSHBaZF6W-XZnrY8tof2B_AQUk8FcQFxgFaoAg4IBBz4N7vb_gtmnDRNyxsJaRXNxvbM55lNPPaOx4TMsMxLeZYwR3A3d5hyM0eFuXREkgv0ILwixnXI6zf4_E12bSFcGBufakQtrfST2XTth_tK_sWqcA_sirtk_8KyNVO4ATTYF65gYbj-kY1ppKg2VEkahVRGVBokjKSa00hQxagJaQRfI2oiLNLgOYpGUd1KUN2iUiFhNNUCOasWVdCKYx1d8hGWMxBtKrltLhEA1FGcGoWECagKLUMXpSChqOFNJ7gBgOMVATCEDYKQMFRrK8Wjuo60RWnQSLmWpan6CiiU2a-ibDfaFlCLGvdAY-Rm9QN4GPKXLaqD_SqNTmgssVg0LY_52lsZKbeA2l9xXW6BgLKamgU9tmwRcJ2zmgWFKgtfoviKvcEPNgfbzFmijYo4YCEQUVpIVLIQHf9exZUI7cNjY-VKa6SSwKBXcJN9THcV_kfkPxftum5jBMQYO5gWuM0hsszzXb0KfNYY8MqMPZXrVKYwOzwoB4orOygj_9maP4ZVilkfk9cfyoVuvassXV1NsAoGOfMj5KgvhBc21kysvw_eqtgPCwi9QDDu1vnj8D9ru-KyJ_MYmakAXf0VHMyzsrTcW7wN3qPdzNcr4t5iw-_snCInqwnjtC6f_tNkbG3pDDnRSCN6lqjd7aeD9UeDT5ujjQ87b78OXt4HAu6M3jwcfdnaffZ8uP5qZ2tz5929wYPt4ZPPw_ePRy82Rq8_niOddtSZm3eqI1GcNJTcyfHEQOhmzsPCyzLPy2H8zdKUsUwWHiYTTASeJp4rkSSFn0o3dnMueRykhShgZneejPeWe_kFMq1EGmRccBbLlBWxL_PATXKo6cUY964myGStg-6tMvNNl-P8TXosnCBTlVa61fvwbvegxS7-tsYkOY50uZ55iYz376zkl8HD7ydXrJW_AWwLtZw |
linkProvider | Directory of Open Access Journals |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=%E9%AB%98%E5%8E%8B%E5%B8%A6%E7%94%B5%E8%AE%BE%E5%A4%87%E7%94%B5%E5%8E%8B%E7%AD%89%E7%BA%A7%E9%9D%9E%E6%8E%A5%E8%A7%A6%E8%AF%86%E5%88%AB%E6%96%B9%E6%B3%95%E7%A0%94%E7%A9%B6&rft.jtitle=%E7%94%B5%E6%B5%8B%E4%B8%8E%E4%BB%AA%E8%A1%A8&rft.au=%E5%94%90%E7%AB%8B%E5%86%9B&rft.au=%E9%AD%8F%E6%9D%B0&rft.au=%E5%91%A8%E5%B9%B4%E8%8D%A3&rft.au=%E6%96%B9%E6%AD%A3%E4%BA%91&rft.date=2017&rft.pub=%E4%BA%91%E5%8D%97%E7%94%B5%E7%BD%91%E6%9C%89%E9%99%90%E8%B4%A3%E4%BB%BB%E5%85%AC%E5%8F%B8%E7%94%B5%E5%8A%9B%E7%A7%91%E5%AD%A6%E7%A0%94%E7%A9%B6%E9%99%A2%2C%E6%98%86%E6%98%8E%2C650217%25%E4%BA%91%E5%8D%97%E7%94%B5%E7%BD%91%E6%9C%89%E9%99%90%E8%B4%A3%E4%BB%BB%E5%85%AC%E5%8F%B8%2C%E6%98%86%E6%98%8E%2C650000&rft.issn=1001-1390&rft.volume=54&rft.issue=24&rft.spage=37&rft.epage=41&rft_id=info:doi/10.3969%2Fj.issn.1001-1390.2017.24.006&rft.externalDocID=dcyyb201724006 |
thumbnail_s | http://utb.summon.serialssolutions.com/2.0.0/image/custom?url=http%3A%2F%2Fimage.cqvip.com%2Fvip1000%2Fqk%2F92179X%2F92179X.jpg http://utb.summon.serialssolutions.com/2.0.0/image/custom?url=http%3A%2F%2Fwww.wanfangdata.com.cn%2Fimages%2FPeriodicalImages%2Fdcyyb%2Fdcyyb.jpg |