Evaluation of endothelial/Descemet membrane complex of eye bank donor corneas using enhanced depth imaging optical coherence tomography

We present a novel method for screening eye bank donor corneas using high definition optical coherence tomography (HD-OCT). This technology allows for the quantification of endothelial/Descemet membrane (En/DM) complex thickness ex vivo. Prospective interventional study. Fifty-two corneal grafts fro...

Full description

Saved in:
Bibliographic Details
Published inClinical ophthalmology (Auckland, N.Z.) Vol. 13; pp. 789 - 794
Main Authors Syed, Zeba A, Gameiro, Gustavo Rosa, Ruggeri, Marco, Elsawy, Amr, Sayed-Ahmed, Ibrahim, Roongpoovapatr, Vatookarn, Abdel-Mottaleb, Mohamed, Abou Shousha, Mohamed
Format Journal Article
LanguageEnglish
Published New Zealand Dove Medical Press Limited 01.05.2019
Dove
Dove Medical Press
Subjects
Online AccessGet full text
ISSN1177-5483
1177-5467
1177-5483
DOI10.2147/OPTH.S185455

Cover

Loading…
Abstract We present a novel method for screening eye bank donor corneas using high definition optical coherence tomography (HD-OCT). This technology allows for the quantification of endothelial/Descemet membrane (En/DM) complex thickness ex vivo. Prospective interventional study. Fifty-two corneal grafts from 27 donors were included in this study. Twenty additional control eyes and 11 eyes with Fuchs' endothelial corneal dystrophy were also evaluated for comparison. A custom built, high speed HD-OCT device (Envisu R2210, Bioptigen, Buffalo Grove, IL, USA) was used to obtain images, and custom-made graph-based segmentation software was used to automatically deconstruct corneal images into micro-layers. HD-OCT imaging was used to scan through the sealed sterile case of donor corneas stored in McCarey-Kaufman medium to image their En/DM complex through the center of the cornea. This technology allowed for quantification of En/DM complex thickness in all donor corneas through the sealed sterile container used to transport graft tissue. Mean En/DM complex thickness of donor corneas was 17±4 μm. The difference between donor cornea En/DM thickness and that of control subjects (16±2 μm) was not statistically significant ( =0.3), suggesting that the transport container and media do not affect measurements. There was a significant difference between En/DM thickness of Fuchs' endothelial corneal dystrophy eyes (25±5 μm) and both donor corneas ( <0.0001) and control subjects ( <0.0001). We have described a new technique to measure En/DM complex thickness in eye bank donor corneas stored in a sealed sterile case. This may represent a novel adjunctive approach to screen corneal grafts for early endothelial disease.
AbstractList Objective: We present a novel method for screening eye bank donor corneas using high definition optical coherence tomography (HD-OCT). This technology allows for the quantification of endothelial/Descemet membrane (En/DM) complex thickness ex vivo. Design: Prospective interventional study. Participants: Fifty-two corneal grafts from 27 donors were included in this study. Twenty additional control eyes and 11 eyes with Fuchs' endothelial corneal dystrophy were also evaluated for comparison. Methods: A custom built, high speed HD-OCT device (Envisu R2210, Bioptigen, Buffalo Grove, IL, USA) was used to obtain images, and custom-made graph-based segmentation software was used to automatically deconstruct corneal images into micro-layers. HD-OCT imaging was used to scan through the sealed sterile case of donor corneas stored in McCarey-Kaufman medium to image their En/DM complex through the center of the cornea. Results: This technology allowed for quantification of En/DM complex thickness in all donor corneas through the sealed sterile container used to transport graft tissue. Mean En/DM complex thickness of donor corneas was 17±4 μm. The difference between donor cornea En/DM thickness and that of control subjects (16±2 μm) was not statistically significant (p=0.3), suggesting that the transport container and media do not affect measurements. There was a significant difference between En/DM thickness of Fuchs' endothelial corneal dystrophy eyes (25±5 μm) and both donor corneas (p<0.0001) and control subjects (p<0.0001). Conclusions: We have described a new technique to measure En/DM complex thickness in eye bank donor corneas stored in a sealed sterile case. This may represent a novel adjunctive approach to screen corneal grafts for early endothelial disease.Objective: We present a novel method for screening eye bank donor corneas using high definition optical coherence tomography (HD-OCT). This technology allows for the quantification of endothelial/Descemet membrane (En/DM) complex thickness ex vivo. Design: Prospective interventional study. Participants: Fifty-two corneal grafts from 27 donors were included in this study. Twenty additional control eyes and 11 eyes with Fuchs' endothelial corneal dystrophy were also evaluated for comparison. Methods: A custom built, high speed HD-OCT device (Envisu R2210, Bioptigen, Buffalo Grove, IL, USA) was used to obtain images, and custom-made graph-based segmentation software was used to automatically deconstruct corneal images into micro-layers. HD-OCT imaging was used to scan through the sealed sterile case of donor corneas stored in McCarey-Kaufman medium to image their En/DM complex through the center of the cornea. Results: This technology allowed for quantification of En/DM complex thickness in all donor corneas through the sealed sterile container used to transport graft tissue. Mean En/DM complex thickness of donor corneas was 17±4 μm. The difference between donor cornea En/DM thickness and that of control subjects (16±2 μm) was not statistically significant (p=0.3), suggesting that the transport container and media do not affect measurements. There was a significant difference between En/DM thickness of Fuchs' endothelial corneal dystrophy eyes (25±5 μm) and both donor corneas (p<0.0001) and control subjects (p<0.0001). Conclusions: We have described a new technique to measure En/DM complex thickness in eye bank donor corneas stored in a sealed sterile case. This may represent a novel adjunctive approach to screen corneal grafts for early endothelial disease.
Zeba A Syed,1 Gustavo Rosa Gameiro,1 Marco Ruggeri,1 Amr Elsawy,1,2 Ibrahim Sayed-Ahmed,1 Vatookarn Roongpoovapatr,1 Mohamed Abdel-Mottaleb,2 Mohamed Abou Shousha11Department of Ophthalmology, Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, FL, USA; 2Department of Electrical and Computer Engineering, University of Miami College of Engineering, Coral Gables, FL, USAObjective: We present a novel method for screening eye bank donor corneas using high definition optical coherence tomography (HD-OCT). This technology allows for the quantification of endothelial/Descemet membrane (En/DM) complex thickness ex vivo.Design: Prospective interventional study.Participants: Fifty-two corneal grafts from 27 donors were included in this study. Twenty additional control eyes and 11 eyes with Fuchs' endothelial corneal dystrophy were also evaluated for comparison.Methods: A custom built, high speed HD-OCT device (Envisu R2210, Bioptigen, Buffalo Grove, IL, USA) was used to obtain images, and custom-made graph-based segmentation software was used to automatically deconstruct corneal images into micro-layers. HD-OCT imaging was used to scan through the sealed sterile case of donor corneas stored in McCarey-Kaufman medium to image their En/DM complex through the center of the cornea.Results: This technology allowed for quantification of En/DM complex thickness in all donor corneas through the sealed sterile container used to transport graft tissue. Mean En/DM complex thickness of donor corneas was 17±4μm. The difference between donor cornea En/DM thickness and that of control subjects (16±2μm) was not statistically significant (p=0.3), suggesting that the transport container and media do not affect measurements. There was a significant difference between En/DM thickness of Fuchs' endothelial corneal dystrophy eyes (25±5μm) and both donor corneas (p<0.0001) and control subjects (p<0.0001).Conclusions: We have described a new technique to measure En/DM complex thickness in eye bank donor corneas stored in a sealed sterile case. This may represent a novel adjunctive approach to screen corneal grafts for early endothelial disease.Keywords: corneal transplant, Fuchs' endothelial corneal dystrophy, corneal graft screening, microscope-integrated OCT
Objective: We present a novel method for screening eye bank donor corneas using high definition optical coherence tomography (HD-OCT). This technology allows for the quantification of endothelial/Descemet membrane (En/DM) complex thickness ex vivo. Design: Prospective interventional study. Participants: Fifty-two corneal grafts from 27 donors were included in this study. Twenty additional control eyes and 11 eyes with Fuchs’ endothelial corneal dystrophy were also evaluated for comparison. Methods: A custom built, high speed HD-OCT device (Envisu R2210, Bioptigen, Buffalo Grove, IL, USA) was used to obtain images, and custom-made graph-based segmentation software was used to automatically deconstruct corneal images into micro-layers. HD-OCT imaging was used to scan through the sealed sterile case of donor corneas stored in McCarey-Kaufman medium to image their En/DM complex through the center of the cornea. Results: This technology allowed for quantification of En/DM complex thickness in all donor corneas through the sealed sterile container used to transport graft tissue. Mean En/DM complex thickness of donor corneas was 17±4 μm. The difference between donor cornea En/DM thickness and that of control subjects (16±2 μm) was not statistically significant ( p =0.3), suggesting that the transport container and media do not affect measurements. There was a significant difference between En/DM thickness of Fuchs’ endothelial corneal dystrophy eyes (25±5 μm) and both donor corneas ( p <0.0001) and control subjects ( p <0.0001). Conclusions: We have described a new technique to measure En/DM complex thickness in eye bank donor corneas stored in a sealed sterile case. This may represent a novel adjunctive approach to screen corneal grafts for early endothelial disease.
Objective: We present a novel method for screening eye bank donor corneas using high definition optical coherence tomography (HD-OCT). This technology allows for the quantification of endothelial/Descemet membrane (En/DM) complex thickness ex vivo. Design: Prospective interventional study. Participants: Fifty-two corneal grafts from 27 donors were included in this study. Twenty additional control eyes and 11 eyes with Fuchs' endothelial corneal dystrophy were also evaluated for comparison. Methods: A custom built, high speed HD-OCT device (Envisu R2210, Bioptigen, Buffalo Grove, IL, USA) was used to obtain images, and custom-made graph-based segmentation software was used to automatically deconstruct corneal images into micro-layers. HD-OCT imaging was used to scan through the sealed sterile case of donor corneas stored in McCarey-Kaufman medium to image their En/DM complex through the center of the cornea. Results: This technology allowed for quantification of En/DM complex thickness in all donor corneas through the sealed sterile container used to transport graft tissue. Mean En/DM complex thickness of donor corneas was 17[+ or -]4 [micro]m. The difference between donor cornea En/DM thickness and that of control subjects (16[+ or -]2 [micro]m) was not statistically significant (p=0.3), suggesting that the transport container and media do not affect measurements. There was a significant difference between En/DM thickness of Fuchs' endothelial corneal dystrophy eyes (25[+ or -]5 [micro]m) and both donor corneas (p<0.0001) and control subjects (p<0.0001). Conclusions: We have described a new technique to measure En/DM complex thickness in eye bank donor corneas stored in a sealed sterile case. This may represent a novel adjunctive approach to screen corneal grafts for early endothelial disease. Keywords: corneal transplant, Fuchs' endothelial corneal dystrophy, corneal graft screening, microscope-integrated OCT
We present a novel method for screening eye bank donor corneas using high definition optical coherence tomography (HD-OCT). This technology allows for the quantification of endothelial/Descemet membrane (En/DM) complex thickness ex vivo. Prospective interventional study. Fifty-two corneal grafts from 27 donors were included in this study. Twenty additional control eyes and 11 eyes with Fuchs' endothelial corneal dystrophy were also evaluated for comparison. A custom built, high speed HD-OCT device (Envisu R2210, Bioptigen, Buffalo Grove, IL, USA) was used to obtain images, and custom-made graph-based segmentation software was used to automatically deconstruct corneal images into micro-layers. HD-OCT imaging was used to scan through the sealed sterile case of donor corneas stored in McCarey-Kaufman medium to image their En/DM complex through the center of the cornea. This technology allowed for quantification of En/DM complex thickness in all donor corneas through the sealed sterile container used to transport graft tissue. Mean En/DM complex thickness of donor corneas was 17±4 μm. The difference between donor cornea En/DM thickness and that of control subjects (16±2 μm) was not statistically significant ( =0.3), suggesting that the transport container and media do not affect measurements. There was a significant difference between En/DM thickness of Fuchs' endothelial corneal dystrophy eyes (25±5 μm) and both donor corneas ( <0.0001) and control subjects ( <0.0001). We have described a new technique to measure En/DM complex thickness in eye bank donor corneas stored in a sealed sterile case. This may represent a novel adjunctive approach to screen corneal grafts for early endothelial disease.
Audience Academic
Author Elsawy, Amr
Gameiro, Gustavo Rosa
Abdel-Mottaleb, Mohamed
Abou Shousha, Mohamed
Syed, Zeba A
Roongpoovapatr, Vatookarn
Ruggeri, Marco
Sayed-Ahmed, Ibrahim
Author_xml – sequence: 1
  givenname: Zeba A
  surname: Syed
  fullname: Syed, Zeba A
– sequence: 2
  givenname: Gustavo Rosa
  surname: Gameiro
  fullname: Gameiro, Gustavo Rosa
– sequence: 3
  givenname: Marco
  orcidid: 0000-0001-6491-8476
  surname: Ruggeri
  fullname: Ruggeri, Marco
– sequence: 4
  givenname: Amr
  surname: Elsawy
  fullname: Elsawy, Amr
– sequence: 5
  givenname: Ibrahim
  surname: Sayed-Ahmed
  fullname: Sayed-Ahmed, Ibrahim
– sequence: 6
  givenname: Vatookarn
  orcidid: 0000-0001-7310-3471
  surname: Roongpoovapatr
  fullname: Roongpoovapatr, Vatookarn
– sequence: 7
  givenname: Mohamed
  surname: Abdel-Mottaleb
  fullname: Abdel-Mottaleb, Mohamed
– sequence: 8
  givenname: Mohamed
  surname: Abou Shousha
  fullname: Abou Shousha, Mohamed
BackLink https://www.ncbi.nlm.nih.gov/pubmed/31190724$$D View this record in MEDLINE/PubMed
BookMark eNptkktr3TAQhU1JaR7trutiKJQuehPLli17Uwhp2gQCKTRdi7E0spXKkiPZofcX9G9X99FwbwlaSIy-OZwZznFyYJ3FJHlLstOcUHZ2-_3u6vQHqUtali-SI0IYW5S0Lg523ofJcQj3WVblWc1eJYcFIU3GcnqU_Ll8BDPDpJ1NnUrRSjf1aDSYsy8YBA44pQMOrQeLqXDDaPD3Glxi2oL9lUpnnY8_3iKEdA7adlGlBytQphLHqU_1AN2q7MZJCzAR7tFjBNLJDa7zMPbL18lLBSbgm-19kvz8enl3cbW4uf12fXF-sxBxjmnR5hJY3hYtaxhtq5JkpMpA1WWNCoRsWctojrIpVI0oUWQKSkGUrGVBa0Hb4iS53uhKB_d89NGbX3IHmq8LznccfLRpkLO6ENA0OWmwpG2ZgyKYAVPxSEChotbnjdY4twNKgXbyYPZE93-s7nnnHnn0TUleR4GPWwHvHmYMEx903LkxcdluDjwvSFFVjFZVRN9v0A6iNW2Vi4pihfPzimQlZSxvInX6DBWPxEGLmBulY32v4cNOQ49gpj44M6_yEPbBd7uzPg35L0kR-LQBhHcheFRPCMn4Kqh8FVS-DWrE8_9woad1DKNjbZ5v-guBL-5T
CitedBy_id crossref_primary_10_1097_ICO_0000000000002583
crossref_primary_10_3390_jcm11061534
ContentType Journal Article
Copyright COPYRIGHT 2019 Dove Medical Press Limited
2019 Syed et al. 2019 Syed et al.
Copyright_xml – notice: COPYRIGHT 2019 Dove Medical Press Limited
– notice: 2019 Syed et al. 2019 Syed et al.
DBID AAYXX
CITATION
NPM
7X8
5PM
DOA
DOI 10.2147/OPTH.S185455
DatabaseName CrossRef
PubMed
MEDLINE - Academic
PubMed Central (Full Participant titles)
DOAJ Directory of Open Access Journals
DatabaseTitle CrossRef
PubMed
MEDLINE - Academic
DatabaseTitleList MEDLINE - Academic




PubMed
Database_xml – sequence: 1
  dbid: DOA
  name: DOAJ Directory of Open Access Journals
  url: https://www.doaj.org/
  sourceTypes: Open Website
– sequence: 2
  dbid: NPM
  name: PubMed
  url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed
  sourceTypes: Index Database
DeliveryMethod fulltext_linktorsrc
Discipline Medicine
DocumentTitleAlternate Syed et al
EISSN 1177-5483
EndPage 794
ExternalDocumentID oai_doaj_org_article_783ca99219e54b52af1e0a7f7f7daecf
PMC6514128
A610547729
31190724
10_2147_OPTH_S185455
Genre Journal Article
GeographicLocations Florida
GeographicLocations_xml – name: Florida
GroupedDBID ---
0YH
29B
2WC
53G
5VS
6J9
7X7
8AO
8FI
8FJ
8G5
AAYXX
ABDBF
ABUWG
ACGFO
ACUHS
ADBBV
ADRAZ
AFKRA
ALIPV
ALMA_UNASSIGNED_HOLDINGS
AOIJS
AZQEC
BAWUL
BCNDV
BENPR
BPHCQ
BVXVI
C1A
CCPQU
CITATION
DIK
DWQXO
E3Z
EBD
EBS
EJD
F5P
FRP
FYUFA
GNUQQ
GROUPED_DOAJ
GUQSH
GX1
HMCUK
HYE
IAO
IHR
IHW
ITC
KQ8
M2O
M48
O5R
O5S
OK1
P2P
PGMZT
PHGZM
PHGZT
PIMPY
PQQKQ
PROAC
RNS
RPM
TDBHL
TR2
UKHRP
VDV
W2D
M~E
NPM
PMFND
7X8
PUEGO
5PM
ID FETCH-LOGICAL-c548t-b2da72b3b7974b6510160af858efacdb7b742ed93f8eedec0fa5c1fd8d348c4b3
IEDL.DBID M48
ISSN 1177-5483
1177-5467
IngestDate Wed Aug 27 01:26:04 EDT 2025
Thu Aug 21 14:07:42 EDT 2025
Thu Sep 04 21:15:50 EDT 2025
Tue Jun 17 20:27:22 EDT 2025
Tue Jun 10 20:26:55 EDT 2025
Thu May 22 21:22:00 EDT 2025
Thu Jan 02 23:00:19 EST 2025
Tue Jul 01 02:21:40 EDT 2025
Thu Apr 24 22:57:36 EDT 2025
IsDoiOpenAccess true
IsOpenAccess true
IsPeerReviewed true
IsScholarly true
Keywords Fuchs’ endothelial corneal dystrophy
corneal graft screening
microscope-integrated OCT
corneal transplant
Language English
License http://creativecommons.org/licenses/by-nc/3.0
This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php).
LinkModel DirectLink
MergedId FETCHMERGED-LOGICAL-c548t-b2da72b3b7974b6510160af858efacdb7b742ed93f8eedec0fa5c1fd8d348c4b3
Notes ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ORCID 0000-0001-7310-3471
0000-0001-6491-8476
OpenAccessLink http://journals.scholarsportal.info/openUrl.xqy?doi=10.2147/OPTH.S185455
PMID 31190724
PQID 2313667466
PQPubID 23479
PageCount 6
ParticipantIDs doaj_primary_oai_doaj_org_article_783ca99219e54b52af1e0a7f7f7daecf
pubmedcentral_primary_oai_pubmedcentral_nih_gov_6514128
proquest_miscellaneous_2313667466
gale_infotracmisc_A610547729
gale_infotracacademiconefile_A610547729
gale_healthsolutions_A610547729
pubmed_primary_31190724
crossref_primary_10_2147_OPTH_S185455
crossref_citationtrail_10_2147_OPTH_S185455
ProviderPackageCode CITATION
AAYXX
PublicationCentury 2000
PublicationDate 20190501
PublicationDateYYYYMMDD 2019-05-01
PublicationDate_xml – month: 05
  year: 2019
  text: 20190501
  day: 01
PublicationDecade 2010
PublicationPlace New Zealand
PublicationPlace_xml – name: New Zealand
PublicationTitle Clinical ophthalmology (Auckland, N.Z.)
PublicationTitleAlternate Clin Ophthalmol
PublicationYear 2019
Publisher Dove Medical Press Limited
Dove
Dove Medical Press
Publisher_xml – name: Dove Medical Press Limited
– name: Dove
– name: Dove Medical Press
SSID ssj0062087
Score 2.164044
Snippet We present a novel method for screening eye bank donor corneas using high definition optical coherence tomography (HD-OCT). This technology allows for the...
Objective: We present a novel method for screening eye bank donor corneas using high definition optical coherence tomography (HD-OCT). This technology allows...
Objective: We present a novel method for screening eye bank donor corneas using high definition optical coherence tomography (HD-OCT). This technology allows...
Zeba A Syed,1 Gustavo Rosa Gameiro,1 Marco Ruggeri,1 Amr Elsawy,1,2 Ibrahim Sayed-Ahmed,1 Vatookarn Roongpoovapatr,1 Mohamed Abdel-Mottaleb,2 Mohamed Abou...
SourceID doaj
pubmedcentral
proquest
gale
pubmed
crossref
SourceType Open Website
Open Access Repository
Aggregation Database
Index Database
Enrichment Source
StartPage 789
SubjectTerms Containers
corneal graft screening
Corneal transplant
Endothelium
Fuchs’ endothelial corneal dystrophy
High definition television
microscope-integrated OCT
Novels
Original Research
Technology
Tomography
SummonAdditionalLinks – databaseName: DOAJ Directory of Open Access Journals
  dbid: DOA
  link: http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwrV3Ni9UwEA-yB_EifltdNYLiQeprm6Rpj6vu8hBWBXdhbyUfk32L2_bxtgv6F_hvO0n6yisiXqS3ZghNZjIfzcxvCHklC2OL2tlU1RlLuRQm1axwaWFLrVFngua-wPn4c7k85Z_OxNlOqy-fExbhgePGLWTFjKprPFgguBaFcjlkSjp8rALjvPbN6mwbTEUdXBZZNbZVkSn65CymvPuePIsvX0-W776hmeK-vG_HGAXM_j81845pmqdN7tihozvk9uhA0oP44XfJDejukZvH4xX5ffLrcMLvpr2j0FlfY3WJYrb46KGbWhhoCy0GyR3QkFAOPwLhT6Badd-p7bt-gyObDtQV9Xnx5zjLKmQKUAvrYUUv2tDbiPbr8CcciVexapAOfTtiYD8gp0eHJx-W6dhtITW4Q0OqC6tkoZmWGGLoUgTsOeUqUYFTxmqpMYoGWzNXoV0FkzklTO5sZRmvDNfsIdnr-g4eEwo5t8IwmQtktYJaMeX8haXAGYtKmIS83W57Y0Yoct8R47LBkMQzqfFMakYmJeT1RL2OEBx_oXvvOTjReODs8ALFqRnFqfmXOCXkhed_E6tQp-PfHKCbKbgPRRLyJlB4BYAfbdRYx4BL91BaM8r9GSUeXDMbfrmVscYP-Wy3DvrrqwZ9blaWkpdlQh5FmZtWxXJ04WTBEyJn0jhb9nyku1gF3HDkKUd35Mn_2Ken5Ba6jnVM_dwne8PmGp6hezbo5-Ek_gYBRjwI
  priority: 102
  providerName: Directory of Open Access Journals
Title Evaluation of endothelial/Descemet membrane complex of eye bank donor corneas using enhanced depth imaging optical coherence tomography
URI https://www.ncbi.nlm.nih.gov/pubmed/31190724
https://www.proquest.com/docview/2313667466
https://pubmed.ncbi.nlm.nih.gov/PMC6514128
https://doaj.org/article/783ca99219e54b52af1e0a7f7f7daecf
Volume 13
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV3da9RAEF_6AeKL-G20nisoPkjaJLubTR5EWr1yCFeL9uB8CvvZK94l510K7V_gv-3sJhcaqiCBPGQnIbszuzOzO_MbhN7wROkktzoUeURCypkKJUlsmOhUSlgzjaQuwXl8ko4m9MuUTbfQptpoO4Drv7p2rp7UZDXfv_p1_REm_AcXxhxTfvD19Gy0_x0UD2VsG-2CTkqdGzam3XlCmkRZW2aFh2CjkyYE_tbbPeXkMfxvr9Q3VFU_jPKGXjq-j-61BiU-bCTgAdoy5UN0Z9wemT9Cv4cdnjeuLDaldjlXcxC7g88OymlharwwC3CaS4N9gLm58oTXBktR_sS6KqsVtKxKI9bYxcmfw1dmPnIAa7OsZ_hi4Wsd4Wrpd8aBeNZkEeK6WrSY2I_R5Hh49mkUttUXQgUjVIcy0YInkkgOLodMmceiEzZjmbFCackleNVG58RmoGeNiqxgKrY604RmikryBO2UVWmeIWxiqpkiPGbAemFyQYR1B5gMvphkTAXo_WbYC9VCk7sKGfMCXBTHpMIxqWiZFKC3HfWygeT4B92R42BH44C0_YNqdV6087LgGVEiz2HdNoxKlggbm0hwC5cWRtkAvXL8L5qs1G45KA7B7GTUuSYBeucpnIjCTyvR5jVA1x20Vo9yr0cJE1n1ml9vZKxwTS76rTTV5boAG5ykKadpGqCnjcx1vSIxmHQ8oQHiPWnsdbvfUl7MPI448JSCefL8P8fzBboL1mLeRHvuoZ16dWlegkVWywHajn6M4M6nfIB2j4Ynp98Gfndj4KfhH0pdO4o
linkProvider Scholars Portal
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Evaluation+of+endothelial%2FDescemet+membrane+complex+of+eye+bank+donor+corneas+using+enhanced+depth+imaging+optical+coherence+tomography&rft.jtitle=Clinical+ophthalmology+%28Auckland%2C+N.Z.%29&rft.au=Syed%2C+Zeba+A&rft.au=Gameiro%2C+Gustavo+Rosa&rft.au=Ruggeri%2C+Marco&rft.au=Elsawy%2C+Amr&rft.date=2019-05-01&rft.issn=1177-5483&rft.eissn=1177-5483&rft.volume=13&rft.spage=789&rft.epage=794&rft_id=info:doi/10.2147%2FOPTH.S185455&rft.externalDBID=n%2Fa&rft.externalDocID=10_2147_OPTH_S185455
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1177-5483&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1177-5483&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1177-5483&client=summon