Multidetector CT of pancreatic ductal adenocarcinoma: Effect of tube voltage and iodine load on tumour conspicuity and image quality

Objectives To compare a low-tube-voltage with or without high-iodine-load multidetector CT (MDCT) protocol with a normal-tube-voltage, normal-iodine-load (standard) protocol in patients with pancreatic ductal adenocarcinoma (PDAC) with respect to tumour conspicuity and image quality. Methods Thirty...

Full description

Saved in:
Bibliographic Details
Published inEuropean radiology Vol. 26; no. 11; pp. 4021 - 4029
Main Authors Loizou, L., Albiin, N., Leidner, B., Axelsson, E., Fischer, M. A., Grigoriadis, A., Del Chiaro, M., Segersvärd, R., Verbeke, C., Sundin, A., Kartalis, N.
Format Journal Article
LanguageEnglish
Published Berlin/Heidelberg Springer Berlin Heidelberg 01.11.2016
Springer Nature B.V
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Objectives To compare a low-tube-voltage with or without high-iodine-load multidetector CT (MDCT) protocol with a normal-tube-voltage, normal-iodine-load (standard) protocol in patients with pancreatic ductal adenocarcinoma (PDAC) with respect to tumour conspicuity and image quality. Methods Thirty consecutive patients (mean age: 66 years, men/women: 14/16) preoperatively underwent triple-phase 64-channel MDCT examinations twice according to: (i) 120-kV standard protocol (PS; 0.75 g iodine (I)/kg body weight, n = 30) and (ii) 80-kV protocol A (PA; 0.75 g I/kg, n = 14) or protocol B (PB; 1 g I/kg, n = 16). Two independent readers evaluated tumour delineation and image quality blindly for all protocols. A third reader estimated the pancreas-to-tumour contrast-to-noise ratio (CNR). Statistical analysis was performed with the Chi-square test. Results Tumour delineation was significantly better in PB and PA compared with PS ( P  = 0.02). The evaluation of image quality was similar for the three protocols (all, P  > 0.05). The highest CNR was observed with PB and was significantly better compared to PA ( P  = 0.02) and PS ( P  = 0.0002). Conclusion In patients with PDAC, a low-tube-voltage, high-iodine-load protocol improves tumour delineation and CNR leading to higher tumour conspicuity compared to standard protocol MDCT. Key Points • Low-tube-voltage high-iodine-load MDCT improves pancreatic cancer conspicuity compared to a standard protocol. • The pancreas-to-tumour attenuation difference increases significantly by reducing the tube voltage. • The radiation exposure dose decreases by reducing the tube voltage.
Bibliography:ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-News-1
ObjectType-Feature-3
content type line 23
ObjectType-Article-1
ObjectType-Feature-2
ISSN:0938-7994
1432-1084
1432-1084
DOI:10.1007/s00330-016-4273-y