Design and evaluation of a novel triaxial isometric trunk muscle strength measurement system
Abstract Maximal strength measurements of the trunk have been used to evaluate the maximum functional capacity of muscles and the potential mechanical overload or overuse of the lumbar spine tissues in order to estimate the risk of developing musculoskeletal injuries. A new triaxial isometric trunk...
Saved in:
Published in | Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine Vol. 223; no. 6; pp. 755 - 766 |
---|---|
Main Authors | , , , , |
Format | Journal Article |
Language | English |
Published |
London, England
SAGE Publications
01.08.2009
SAGE PUBLICATIONS, INC |
Subjects | |
Online Access | Get full text |
ISSN | 0954-4119 2041-3033 |
DOI | 10.1243/09544119JEIM537 |
Cover
Abstract | Abstract
Maximal strength measurements of the trunk have been used to evaluate the maximum functional capacity of muscles and the potential mechanical overload or overuse of the lumbar spine tissues in order to estimate the risk of developing musculoskeletal injuries. A new triaxial isometric trunk strength measurement system was designed and developed in the present study, and its reliability and performance was investigated. The system consisted of three main revolute joints, equipped with torque sensors, which intersect at L5—S1 and adjustment facilities to fit the body anthropometry and to accommodate both symmetric and asymmetric postures in both seated and standing positions. The dynamics of the system was formulated to resolve validly the moment generated by trunk muscles in the three anatomic planes. The optimal gain and offset of the system were obtained using deadweights based on the least-squares linear regression analysis. The R2 results of calibration for all loading courses of all joints were higher than 0.99, which indicated an excellent linear correlation. The results of the validation analysis of the regression model suggested that the mean absolute error and the r.m.s. error were less than 2 per cent of the applied load. The maximum value of the minimum detectable change was found to be 1.63 N m for the sagittal plane torque measurement, 0.8 per cent of the full-scale load. The trial-to-trial variability analysis of the device using deadweights provided intra-class correlation coefficients of higher than 0.99, suggesting excellent reliability. The cross-talk analysis of the device indicated maximum cross-talks of 1.7 per cent and 3.4 per cent when the system was subjected to flexion—extension and lateral bending torques respectively. The trial-to-trial variability of the system during in-vivo strength measurement tests resulted in good to excellent reliability, with intra-class correlation coefficients ranging from 0.69 to 0.91. The results of the maximum voluntary isometric torques exertion measurements for 30 subjects indicated good agreement with the previously published data in the literature. The extensive capabilities and high reliability of the system are promising for more comprehensive investigations on the trunk biomechanics in future, e.g. isometric strength measurement at symmetric and asymmetric postures, muscle endurance, and recruitment pattern analysis. |
---|---|
AbstractList | Maximal strength measurements of the trunk have been used to evaluate the maximum functional capacity of muscles and the potential mechanical overload or overuse of the lumbar spine tissues in order to estimate the risk of developing musculoskeletal injuries. A new triaxial isometric trunk strength measurement system was designed and developed in the present study, and its reliability and performance was investigated. The system consisted of three main revolute joints, equipped with torque sensors, which intersect at L5-S1 and adjustment facilities to fit the body anthropometry and to accommodate both symmetric and asymmetric postures in both seated and standing positions. The dynamics of the system was formulated to resolve validly the moment generated by trunk muscles in the three anatomic planes. The optimal gain and offset of the system were obtained using deadweights based on the least-squares linear regression analysis. The R^sup 2^ results of calibration for all loading courses of all joints were higher than 0.99, which indicated an excellent linear correlation. The results of the validation analysis of the regression model suggested that the mean absolute error and the r.m.s. error were less than 2 per cent of the applied load. The maximum value of the minimum detectable change was found to be 1.63 N m for the sagittal plane torque measurement, 0.8 per cent of the full-scale load. The trial-to-trial variability analysis of the device using deadweights provided intra-class correlation coefficients of higher than 0.99, suggesting excellent reliability. The cross-talk analysis of the device indicated maximum cross-talks of 1.7 per cent and 3.4 per cent when the system was subjected to flexion-extension and lateral bending torques respectively. The trial-to-trial variability of the system during in-vivo strength measurement tests resulted in good to excellent reliability, with intra-class correlation coefficients ranging from 0.69 to 0.91. The results of the maximum voluntary isometric torques exertion measurements for 30 subjects indicated good agreement with the previously published data in the literature. The extensive capabilities and high reliability of the system are promising for more comprehensive investigations on the trunk biomechanics in future, e.g. isometric strength measurement at symmetric and asymmetric postures, muscle endurance, and recruitment pattern analysis. [PUBLICATION ABSTRACT] Maximal strength measurements of the trunk have been used to evaluate the maximum functional capacity of muscles and the potential mechanical overload or overuse of the lumbar spine tissues in order to estimate the risk of developing musculoskeletal injuries. A new triaxial isometric trunk strength measurement system was designed and developed in the present study, and its reliability and performance was investigated. The system consisted of three main revolute joints, equipped with torque sensors, which intersect at L5-S1 and adjustment facilities to fit the body anthropometry and to accommodate both symmetric and asymmetric postures in both seated and standing positions. The dynamics of the system was formulated to resolve validly the moment generated by trunk muscles in the three anatomic planes. The optimal gain and offset of the system were obtained using deadweights based on the least-squares linear regression analysis. The R2 results of calibration for all loading courses of all joints were higher than 0.99, which indicated an excellent linear correlation. The results of the validation analysis of the regression model suggested that the mean absolute error and the r.m.s. error were less than 2 per cent of the applied load. The maximum value of the minimum detectable change was found to be 1.63 Nm for the sagittal plane torque measurement, 0.8 per cent of the full-scale load. The trial-to-trial variability analysis of the device using deadweights provided intra-class correlation coefficients of higher than 0.99, suggesting excellent reliability. The cross-talk analysis of the device indicated maximum cross-talks of 1.7 per cent and 3.4 per cent when the system was subjected to flexion-extension and lateral bending torques respectively. The trial-to-trial variability of the system during in-vivo strength measurement tests resulted in good to excellent reliability, with intra-class correlation coefficients ranging from 0.69 to 0.91. The results of the maximum voluntary isometric torques exertion measurements for 30 subjects indicated good agreement with the previously published data in the literature. The extensive capabilities and high reliability of the system are promising for more comprehensive investigations on the trunk biomechanics in future, e.g. isometric strength measurement at symmetric and asymmetric postures, muscle endurance, and recruitment pattern analysis. Maximal strength measurements of the trunk have been used to evaluate the maximum functional capacity of muscles and the potential mechanical overload or overuse of the lumbar spine tissues in order to estimate the risk of developing musculoskeletal injuries. A new triaxial isometric trunk strength measurement system was designed and developed in the present study, and its reliability and performance was investigated. The system consisted of three main revolute joints, equipped with torque sensors, which intersect at L5-S1 and adjustment facilities to fit the body anthropometry and to accommodate both symmetric and asymmetric postures in both seated and standing positions. The dynamics of the system was formulated to resolve validly the moment generated by trunk muscles in the three anatomic planes. The optimal gain and offset of the system were obtained using deadweights based on the least-squares linear regression analysis. The Rsup 2 results of calibration for all loading courses of all joints were higher than 0.99, which indicated an excellent linear correlation. The results of the validation analysis of the regression model suggested that the mean absolute error and the r.m.s. error were less than 2 per cent of the applied load. The maximum value of the minimum detectable change was found to be 1.63 N m for the sagittal plane torque measurement, 0.8 per cent of the full-scale load. The trial-to-trial variability analysis of the device using deadweights provided intra-class correlation coefficients of higher than 0.99, suggesting excellent reliability. The cross-talk analysis of the device indicated maximum cross-talks of 1.7 per cent and 3.4 per cent when the system was subjected to flexion-extension and lateral bending torques respectively. The trial-to-trial variability of the system during in-vivo strength measurement tests resulted in good to excellent reliability, with intra-class correlation coefficients ranging from 0.69 to 0.91. The results of the maximum voluntary isometric torques exertion measurements for 30 subjects indicated good agreement with the previously published data in the literature. The extensive capabilities and high reliability of the system are promising for more comprehensive investigations on the trunk biomechanics in future, e.g. isometric strength measurement at symmetric and asymmetric postures, muscle endurance, and recruitment pattern analysis. [PUBLICATION ABSTRACT] Abstract Maximal strength measurements of the trunk have been used to evaluate the maximum functional capacity of muscles and the potential mechanical overload or overuse of the lumbar spine tissues in order to estimate the risk of developing musculoskeletal injuries. A new triaxial isometric trunk strength measurement system was designed and developed in the present study, and its reliability and performance was investigated. The system consisted of three main revolute joints, equipped with torque sensors, which intersect at L5—S1 and adjustment facilities to fit the body anthropometry and to accommodate both symmetric and asymmetric postures in both seated and standing positions. The dynamics of the system was formulated to resolve validly the moment generated by trunk muscles in the three anatomic planes. The optimal gain and offset of the system were obtained using deadweights based on the least-squares linear regression analysis. The R2 results of calibration for all loading courses of all joints were higher than 0.99, which indicated an excellent linear correlation. The results of the validation analysis of the regression model suggested that the mean absolute error and the r.m.s. error were less than 2 per cent of the applied load. The maximum value of the minimum detectable change was found to be 1.63 N m for the sagittal plane torque measurement, 0.8 per cent of the full-scale load. The trial-to-trial variability analysis of the device using deadweights provided intra-class correlation coefficients of higher than 0.99, suggesting excellent reliability. The cross-talk analysis of the device indicated maximum cross-talks of 1.7 per cent and 3.4 per cent when the system was subjected to flexion—extension and lateral bending torques respectively. The trial-to-trial variability of the system during in-vivo strength measurement tests resulted in good to excellent reliability, with intra-class correlation coefficients ranging from 0.69 to 0.91. The results of the maximum voluntary isometric torques exertion measurements for 30 subjects indicated good agreement with the previously published data in the literature. The extensive capabilities and high reliability of the system are promising for more comprehensive investigations on the trunk biomechanics in future, e.g. isometric strength measurement at symmetric and asymmetric postures, muscle endurance, and recruitment pattern analysis. Maximal strength measurements of the trunk have been used to evaluate the maximum functional capacity of muscles and the potential mechanical overload or overuse of the lumbar spine tissues in order to estimate the risk of developing musculoskeletal injuries. A new triaxial isometric trunk strength measurement system was designed and developed in the present study, and its reliability and performance was investigated. The system consisted of three main revolute joints, equipped with torque sensors, which intersect at L5-S1 and adjustment facilities to fit the body anthropometry and to accommodate both symmetric and asymmetric postures in both seated and standing positions. The dynamics of the system was formulated to resolve validly the moment generated by trunk muscles in the three anatomic planes. The optimal gain and offset of the system were obtained using deadweights based on the least-squares linear regression analysis. The R2 results of calibration for all loading courses of all joints were higher than 0.99, which indicated an excellent linear correlation. The results of the validation analysis of the regression model suggested that the mean absolute error and the r.m.s. error were less than 2 per cent of the applied load. The maximum value of the minimum detectable change was found to be 1.63 Nm for the sagittal plane torque measurement, 0.8 per cent of the full-scale load. The trial-to-trial variability analysis of the device using deadweights provided intra-class correlation coefficients of higher than 0.99, suggesting excellent reliability. The cross-talk analysis of the device indicated maximum cross-talks of 1.7 per cent and 3.4 per cent when the system was subjected to flexion-extension and lateral bending torques respectively. The trial-to-trial variability of the system during in-vivo strength measurement tests resulted in good to excellent reliability, with intra-class correlation coefficients ranging from 0.69 to 0.91. The results of the maximum voluntary isometric torques exertion measurements for 30 subjects indicated good agreement with the previously published data in the literature. The extensive capabilities and high reliability of the system are promising for more comprehensive investigations on the trunk biomechanics in future, e.g. isometric strength measurement at symmetric and asymmetric postures, muscle endurance, and recruitment pattern analysis.Maximal strength measurements of the trunk have been used to evaluate the maximum functional capacity of muscles and the potential mechanical overload or overuse of the lumbar spine tissues in order to estimate the risk of developing musculoskeletal injuries. A new triaxial isometric trunk strength measurement system was designed and developed in the present study, and its reliability and performance was investigated. The system consisted of three main revolute joints, equipped with torque sensors, which intersect at L5-S1 and adjustment facilities to fit the body anthropometry and to accommodate both symmetric and asymmetric postures in both seated and standing positions. The dynamics of the system was formulated to resolve validly the moment generated by trunk muscles in the three anatomic planes. The optimal gain and offset of the system were obtained using deadweights based on the least-squares linear regression analysis. The R2 results of calibration for all loading courses of all joints were higher than 0.99, which indicated an excellent linear correlation. The results of the validation analysis of the regression model suggested that the mean absolute error and the r.m.s. error were less than 2 per cent of the applied load. The maximum value of the minimum detectable change was found to be 1.63 Nm for the sagittal plane torque measurement, 0.8 per cent of the full-scale load. The trial-to-trial variability analysis of the device using deadweights provided intra-class correlation coefficients of higher than 0.99, suggesting excellent reliability. The cross-talk analysis of the device indicated maximum cross-talks of 1.7 per cent and 3.4 per cent when the system was subjected to flexion-extension and lateral bending torques respectively. The trial-to-trial variability of the system during in-vivo strength measurement tests resulted in good to excellent reliability, with intra-class correlation coefficients ranging from 0.69 to 0.91. The results of the maximum voluntary isometric torques exertion measurements for 30 subjects indicated good agreement with the previously published data in the literature. The extensive capabilities and high reliability of the system are promising for more comprehensive investigations on the trunk biomechanics in future, e.g. isometric strength measurement at symmetric and asymmetric postures, muscle endurance, and recruitment pattern analysis. Abstract Maximal strength measurements of the trunk have been used to evaluate the maximum functional capacity of muscles and the potential mechanical overload or overuse of the lumbar spine tissues in order to estimate the risk of developing musculoskeletal injuries. A new triaxial isometric trunk strength measurement system was designed and developed in the present study, and its reliability and performance was investigated. The system consisted of three main revolute joints, equipped with torque sensors, which intersect at L5--S1 and adjustment facilities to fit the body anthropometry and to accommodate both symmetric and asymmetric postures in both seated and standing positions. The dynamics of the system was formulated to resolve validly the moment generated by trunk muscles in the three anatomic planes. The optimal gain and offset of the system were obtained using deadweights based on the least-squares linear regression analysis. The R 2 results of calibration for all loading courses of all joints were higher than 0.99, which indicated an excellent linear correlation. The results of the validation analysis of the regression model suggested that the mean absolute error and the r.m.s. error were less than 2 per cent of the applied load. The maximum value of the minimum detectable change was found to be 1.63 N m for the sagittal plane torque measurement, 0.8 per cent of the full-scale load. The trial-to-trial variability analysis of the device using deadweights provided intra-class correlation coefficients of higher than 0.99, suggesting excellent reliability. The cross-talk analysis of the device indicated maximum cross-talks of 1.7 per cent and 3.4 per cent when the system was subjected to flexion--extension and lateral bending torques respectively. The trial-to-trial variability of the system during in-vivo strength measurement tests resulted in good to excellent reliability, with intra-class correlation coefficients ranging from 0.69 to 0.91. The results of the maximum voluntary isometric torques exertion measurements for 30 subjects indicated good agreement with the previously published data in the literature. The extensive capabilities and high reliability of the system are promising for more comprehensive investigations on the trunk biomechanics in future, e.g. isometric strength measurement at symmetric and asymmetric postures, muscle endurance, and recruitment pattern analysis. Maximal strength measurements of the trunk have been used to evaluate the maximum functional capacity of muscles and the potential mechanical overload or overuse of the lumbar spine tissues in order to estimate the risk of developing musculoskeletal injuries. A new triaxial isometric trunk strength measurement system was designed and developed in the present study, and its reliability and performance was investigated. The system consisted of three main revolute joints, equipped with torque sensors, which intersect at L5—S1 and adjustment facilities to fit the body anthropometry and to accommodate both symmetric and asymmetric postures in both seated and standing positions. The dynamics of the system was formulated to resolve validly the moment generated by trunk muscles in the three anatomic planes. The optimal gain and offset of the system were obtained using deadweights based on the least-squares linear regression analysis. The R 2 results of calibration for all loading courses of all joints were higher than 0.99, which indicated an excellent linear correlation. The results of the validation analysis of the regression model suggested that the mean absolute error and the r.m.s. error were less than 2 per cent of the applied load. The maximum value of the minimum detectable change was found to be 1.63 N m for the sagittal plane torque measurement, 0.8 per cent of the full-scale load. The trial-to-trial variability analysis of the device using deadweights provided intra-class correlation coefficients of higher than 0.99, suggesting excellent reliability. The cross-talk analysis of the device indicated maximum cross-talks of 1.7 per cent and 3.4 per cent when the system was subjected to flexion—extension and lateral bending torques respectively. The trial-to-trial variability of the system during in-vivo strength measurement tests resulted in good to excellent reliability, with intra-class correlation coefficients ranging from 0.69 to 0.91. The results of the maximum voluntary isometric torques exertion measurements for 30 subjects indicated good agreement with the previously published data in the literature. The extensive capabilities and high reliability of the system are promising for more comprehensive investigations on the trunk biomechanics in future, e.g. isometric strength measurement at symmetric and asymmetric postures, muscle endurance, and recruitment pattern analysis. |
Author | Azghani, M R Parnianpour, M Vossoughi, G Meghdari, A Farahmand, F |
Author_xml | – sequence: 1 givenname: M R surname: Azghani fullname: Azghani, M R – sequence: 2 givenname: F surname: Farahmand fullname: Farahmand, F – sequence: 3 givenname: A surname: Meghdari fullname: Meghdari, A – sequence: 4 givenname: G surname: Vossoughi fullname: Vossoughi, G – sequence: 5 givenname: M surname: Parnianpour fullname: Parnianpour, M |
BackLink | https://www.ncbi.nlm.nih.gov/pubmed/19743641$$D View this record in MEDLINE/PubMed |
BookMark | eNqF0s1PFDEUAPDGQGRBz95MIwleGOnr5_ZoABWD8aI3k0m3-2YdnGmx7RD47-26GM0m4Klp3--9tH1vn-yEGJCQF8DeAJfihFklJYD9eH7xSQnzhMw4k9AIJsQOma2jzTq8R_ZzvmKMATD9lOyBNVJoCTPy7QxzvwrUhSXFGzdMrvQx0NhRR0O8wYGW1Lvb3g20z3HEuvP1aAo_6DhlPyDNJWFYle90RJenhCOGQvNdLjg-I7udGzI-v18PyNd3519OPzSXn99fnL69bLzirDTGci-cYB5hLtEbzTRKb8FYLywy5ztmFFdisdS6sxIEFyDAQ-dgYY1GcUBeb-pep_hzwlzasc8eh8EFjFNujYG54nPgVR49KrXRUkvF_guFAim1mFf4agtexSmF-tyW1y82imlR0eFDCCyTvBayqqqX92pajLhsr1M_unTX_ulWBScb4FPMOWH3l7B2PQ_t1jzUDLWV4fvyu8UluX54JO94k5fdCv-57AP8F1ozw1M |
CitedBy_id | crossref_primary_10_1080_00140139_2022_2122587 crossref_primary_10_3233_WOR_211397 crossref_primary_10_1371_journal_pone_0270101 crossref_primary_10_1038_s41598_025_87802_1 crossref_primary_10_1177_0954411920913374 crossref_primary_10_1177_09544119211015562 crossref_primary_10_1177_09544119231221896 crossref_primary_10_1177_0954411913486078 crossref_primary_10_1177_09544119231172862 crossref_primary_10_4184_asj_2014_8_5_659 crossref_primary_10_1007_s11332_023_01137_w crossref_primary_10_1016_j_jbiomech_2015_06_032 crossref_primary_10_1016_j_jbiomech_2017_11_007 crossref_primary_10_1177_09544119221114208 crossref_primary_10_1109_TNSRE_2013_2289929 crossref_primary_10_1016_j_jbiomech_2013_06_018 crossref_primary_10_1080_10803548_2024_2440271 crossref_primary_10_1177_09544119231177564 crossref_primary_10_1097_BRS_0000000000000628 crossref_primary_10_1177_0954411920987035 |
Cites_doi | 10.1016/0169-8141(95)00042-9 10.1097/00007632-199508000-00001 10.1097/00007632-199409000-00027 10.1097/00002517-199912000-00011 10.1080/0002889738506892 10.1002/jor.1100110606 10.2519/jospt.1982.3.4.164 10.1016/S0021-9290(01)00222-6 10.1097/00007632-200012010-00018 10.1097/00007632-199310000-00019 10.1016/S1050-6411(98)00011-X 10.1097/BPO.0b013e3180317a35 10.2519/jospt.1987.9.4.141 10.1097/00007632-198809000-00004 10.1016/0268-0033(93)90015-A 10.1016/j.ejpain.2006.05.005 10.1080/14034940600552051 10.1097/00007632-198011000-00008 10.1016/S0021-9290(07)70264-6 10.1097/00007632-199208000-00009 10.1080/10255840802020404 10.1016/S0021-9290(07)70151-3 10.1097/00007632-199812010-00011 10.1097/00007632-198909000-00004 10.1016/j.clinbiomech.2007.11.017 10.1016/S0268-0033(00)00068-1 10.1097/00007632-198904000-00012 10.1097/00007632-199312000-00018 10.1016/S0268-0033(99)00078-9 10.1097/BRS.0b013e31818aec05 10.36076/ppj.2000/3/167 |
ContentType | Journal Article |
Copyright | 2009 Institution of Mechanical Engineers Copyright Professional Engineering Publishing Ltd Aug 2009 |
Copyright_xml | – notice: 2009 Institution of Mechanical Engineers – notice: Copyright Professional Engineering Publishing Ltd Aug 2009 |
DBID | AAYXX CITATION CGR CUY CVF ECM EIF NPM 7QF 7QO 7QQ 7SC 7SE 7SP 7SR 7TA 7TB 7U5 8BQ 8FD F28 FR3 H8D H8G JG9 JQ2 K9. KR7 L7M L~C L~D P64 3V. 7X7 7XB 88A 88E 88I 8AO 8FE 8FG 8FH 8FI 8FJ 8FK ABJCF ABUWG AFKRA AZQEC BBNVY BENPR BGLVJ BHPHI CCPQU DWQXO FYUFA GHDGH GNUQQ HCIFZ L6V LK8 M0S M1P M2P M7P M7S PHGZM PHGZT PJZUB PKEHL PPXIY PQEST PQGLB PQQKQ PQUKI PTHSS Q9U 7X8 |
DOI | 10.1243/09544119JEIM537 |
DatabaseName | CrossRef Medline MEDLINE MEDLINE (Ovid) MEDLINE MEDLINE PubMed Aluminium Industry Abstracts Biotechnology Research Abstracts Ceramic Abstracts Computer and Information Systems Abstracts Corrosion Abstracts Electronics & Communications Abstracts Engineered Materials Abstracts Materials Business File Mechanical & Transportation Engineering Abstracts Solid State and Superconductivity Abstracts METADEX Technology Research Database ANTE: Abstracts in New Technology & Engineering Engineering Research Database Aerospace Database Copper Technical Reference Library Materials Research Database ProQuest Computer Science Collection ProQuest Health & Medical Complete (Alumni) Civil Engineering Abstracts Advanced Technologies Database with Aerospace Computer and Information Systems Abstracts Academic Computer and Information Systems Abstracts Professional Biotechnology and BioEngineering Abstracts ProQuest Central (Corporate) Health & Medical Collection ProQuest Central (purchase pre-March 2016) Biology Database (Alumni Edition) Medical Database (Alumni Edition) Science Database (Alumni Edition) ProQuest Pharma Collection ProQuest SciTech Collection ProQuest Technology Collection ProQuest Natural Science Journals Hospital Premium Collection Hospital Premium Collection (Alumni Edition) ProQuest Central (Alumni) (purchase pre-March 2016) Materials Science & Engineering Collection ProQuest Central (Alumni) ProQuest Central UK/Ireland ProQuest Central Essentials Biological Science Collection ProQuest Central ProQuest Technology Collection Natural Science Collection ProQuest One Community College ProQuest Central Health Research Premium Collection Health Research Premium Collection (Alumni) ProQuest Central Student SciTech Premium Collection ProQuest Engineering Collection Biological Sciences ProQuest Health & Medical Collection Medical Database Science Database Biological Science Database Engineering Database ProQuest Central Premium ProQuest One Academic (New) ProQuest Health & Medical Research Collection ProQuest One Academic Middle East (New) ProQuest One Health & Nursing ProQuest One Academic Eastern Edition (DO NOT USE) ProQuest One Applied & Life Sciences ProQuest One Academic ProQuest One Academic UKI Edition Engineering Collection ProQuest Central Basic MEDLINE - Academic |
DatabaseTitle | CrossRef MEDLINE Medline Complete MEDLINE with Full Text PubMed MEDLINE (Ovid) Materials Research Database Civil Engineering Abstracts Aluminium Industry Abstracts Technology Research Database Computer and Information Systems Abstracts – Academic Mechanical & Transportation Engineering Abstracts Electronics & Communications Abstracts ProQuest Computer Science Collection Computer and Information Systems Abstracts ProQuest Health & Medical Complete (Alumni) Ceramic Abstracts Materials Business File METADEX Biotechnology and BioEngineering Abstracts Computer and Information Systems Abstracts Professional Aerospace Database Copper Technical Reference Library Engineered Materials Abstracts Biotechnology Research Abstracts Solid State and Superconductivity Abstracts Engineering Research Database Corrosion Abstracts Advanced Technologies Database with Aerospace ANTE: Abstracts in New Technology & Engineering ProQuest Central Student ProQuest Central Essentials SciTech Premium Collection ProQuest One Applied & Life Sciences Health Research Premium Collection Natural Science Collection Health & Medical Research Collection Biological Science Collection ProQuest Central (New) ProQuest Medical Library (Alumni) Engineering Collection Engineering Database ProQuest Science Journals (Alumni Edition) ProQuest Biological Science Collection ProQuest One Academic Eastern Edition ProQuest Hospital Collection ProQuest Technology Collection Health Research Premium Collection (Alumni) Biological Science Database ProQuest Hospital Collection (Alumni) ProQuest Health & Medical Complete ProQuest One Academic UKI Edition ProQuest One Academic ProQuest One Academic (New) Technology Collection ProQuest One Academic Middle East (New) ProQuest Central (Alumni Edition) ProQuest One Community College ProQuest One Health & Nursing ProQuest Natural Science Collection ProQuest Pharma Collection ProQuest Biology Journals (Alumni Edition) ProQuest Central ProQuest Health & Medical Research Collection ProQuest Engineering Collection Health and Medicine Complete (Alumni Edition) ProQuest Central Korea ProQuest Central Basic ProQuest Science Journals ProQuest SciTech Collection ProQuest Medical Library Materials Science & Engineering Collection ProQuest Central (Alumni) MEDLINE - Academic |
DatabaseTitleList | Materials Research Database Solid State and Superconductivity Abstracts MEDLINE - Academic Materials Research Database CrossRef MEDLINE |
Database_xml | – sequence: 1 dbid: NPM name: PubMed url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed sourceTypes: Index Database – sequence: 2 dbid: EIF name: MEDLINE url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search sourceTypes: Index Database – sequence: 3 dbid: 8FG name: ProQuest Technology Collection url: https://search.proquest.com/technologycollection1 sourceTypes: Aggregation Database |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Medicine Engineering |
EISSN | 2041-3033 |
EndPage | 766 |
ExternalDocumentID | 1871874751 19743641 10_1243_09544119JEIM537 10.1243_09544119JEIM537 |
Genre | Evaluation Studies Research Support, Non-U.S. Gov't Journal Article |
GroupedDBID | --- -TN -~X .DC 0R~ 123 29P 4.4 53G 7X7 88E 88I 8AO 8FE 8FG 8FH 8FI 8FJ 8R4 8R5 AAFNC AALXP AAOTM AAPFT AAQDB AAWTL ABIDT ABJCF ABUBZ ABUJY ABUWG ACGFS ACGOD ACIWK ACPRK ADBBV ADEBD ADQAE AEDFJ AEWDL AFKRA AFKRG AFRAH AFWMB AGQPQ AHDMH AHMBA AJCXD AJUZI AKDDG ALIPV ALMA_UNASSIGNED_HOLDINGS ARTOV ASPBG AVWKF AZFZN AZQEC BBNVY BENPR BGLVJ BHPHI BPACV BPHCQ BVXVI CAG CCPQU COF CS3 DWQXO EBS EJD F5P FEDTE FHBDP FYUFA GNUQQ H13 HCIFZ HMCUK HVGLF HZ~ I6U IL9 J8X L6V LK8 M1P M2P M7P M7S P.B PHGZM PHGZT PQQKQ PROAC PSQYO PTHSS Q1R Q2X Q7S SAUOL SCNPE SFC UKHRP YNT ~33 AAYXX CITATION ACRPL ADNMO ADYCS CGR CUY CVF ECM EIF NPM O9- PJZUB PPXIY PQGLB PRI 7QF 7QO 7QQ 7SC 7SE 7SP 7SR 7TA 7TB 7U5 8BQ 8FD F28 FR3 H8D H8G JG9 JQ2 K9. KR7 L7M L~C L~D P64 3V. 7XB 88A 8FK PKEHL PQEST PQUKI Q9U PUEGO 7X8 |
ID | FETCH-LOGICAL-c520t-792c3a30ce184ec7606e4c9179c39e0acf075253bd66f941323131c1fa1b976e3 |
IEDL.DBID | 8FG |
ISSN | 0954-4119 |
IngestDate | Thu Sep 04 17:15:13 EDT 2025 Fri Sep 05 04:43:51 EDT 2025 Fri Sep 05 12:53:10 EDT 2025 Wed Aug 13 10:02:03 EDT 2025 Wed Aug 13 11:33:12 EDT 2025 Mon Jul 21 05:59:24 EDT 2025 Tue Jul 01 05:23:40 EDT 2025 Thu Apr 24 23:08:25 EDT 2025 Tue Jun 17 22:30:45 EDT 2025 |
IsPeerReviewed | true |
IsScholarly | true |
Issue | 6 |
Keywords | maximum voluntary exertion trunk triaxial strength measurement design reliability |
Language | English |
License | https://journals.sagepub.com/page/policies/text-and-data-mining-license |
LinkModel | DirectLink |
MergedId | FETCHMERGED-LOGICAL-c520t-792c3a30ce184ec7606e4c9179c39e0acf075253bd66f941323131c1fa1b976e3 |
Notes | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 14 ObjectType-Article-2 ObjectType-Feature-1 content type line 23 ObjectType-Undefined-1 ObjectType-Feature-3 |
PMID | 19743641 |
PQID | 236475063 |
PQPubID | 48974 |
PageCount | 12 |
ParticipantIDs | proquest_miscellaneous_771852812 proquest_miscellaneous_67646450 proquest_miscellaneous_35144638 proquest_journals_236475063 proquest_journals_1904263895 pubmed_primary_19743641 crossref_primary_10_1243_09544119JEIM537 crossref_citationtrail_10_1243_09544119JEIM537 sage_journals_10_1243_09544119JEIM537 |
ProviderPackageCode | CITATION AAYXX |
PublicationCentury | 2000 |
PublicationDate | 2009-08-01 |
PublicationDateYYYYMMDD | 2009-08-01 |
PublicationDate_xml | – month: 08 year: 2009 text: 2009-08-01 day: 01 |
PublicationDecade | 2000 |
PublicationPlace | London, England |
PublicationPlace_xml | – name: London, England – name: England – name: London |
PublicationTitle | Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine |
PublicationTitleAlternate | Proc Inst Mech Eng H |
PublicationYear | 2009 |
Publisher | SAGE Publications SAGE PUBLICATIONS, INC |
Publisher_xml | – name: SAGE Publications – name: SAGE PUBLICATIONS, INC |
References | Ihlrbaek, Hansson, Laerum, Brage, Erikson, Holm, Svendsrod, Indahl 2006; 34 Marras, Davis, Granata 1998; 8 Sparto, Parnianpour 1999; 12 Larivière, Gagnon, Gravel, Arsenault, Dumas, Goyette, Loisel 2001; 16 Khalaf, Parnianpour, Sparto, Simon 1997; 34 Bigos, Battié, Fisher, Hansson, Spengler, Nachemson 1992; 17 Mousavi, Olyaei, Talebian, Sanjari, Parnianpour 2009; 34 Sparto, Parnianpour 1998; 23 Ladin, Murthy, DeLuca 1989; 14 Schneider, Mohnen, Schiltenwolf, Rau 2007; 11 Sheikhzadeh, Parnianpour, Nordin 2008; 23 Marras, Mirka 1993; 11 Wu, Siegler, Allard, Kirtley, Leardini, Rosenbaum, Whittle, D'Lima, Cristofolini, Witte, Schmid, Stokes 2002; 35 Weir 2005; 19 Parnianpour, Li, Nordin, Frankel 1989; 49 Azghani, Farahmand, Meghdari, Vossoughi, Khamse, Hakkak, Parnianpour 2007; 40 Kumar 1996; 17 Mokhtarzadeh, Parnianpour, Farahmand 2007; 40 Manchikanti 2000; 3 Parnianpour, Nordin, Kahanovitz, Frankel 1988; 13 Seeds, Levene, Goldberg 1987; 9 Ross, Parnianpour, Martin 1993; 18 Davies, Gould 1982; 3 Lee, Kuo 2000; 15 Mclntyre, Glover, Reynolds 1993; 8 Mohseni-Bandpei, Bagheri-Nesami, Shayesteh-Azar 2007; 27 Chaffin, Park 1973; 34 Malchaire, Masset 1995; 20 Tan, Parnianpour, Nordin, Hofer, Willems 1994; 18 Tan, Parnianpour, Nordin, Hofer, Willems 1994; 19 Parnianpour, Li, Nordin, Kahanovitz 1989; 14 Hoogendoorn, Bongers, de Vet, Douwes, Koes, Miedema, Ariëns, Bouter 2000; 25 Arjmand, Shirazi-Adl, Parnianpour 2008; 11 McNeill, Warwick, Andersson, Schultz 1980; 5 bibr5-09544119JEIM537 bibr2-09544119JEIM537 bibr32-09544119JEIM537 bibr28-09544119JEIM537 Khalaf K. A. (bibr31-09544119JEIM537) 1997; 34 bibr38-09544119JEIM537 bibr11-09544119JEIM537 bibr42-09544119JEIM537 Azghani M. R. (bibr24-09544119JEIM537) 2009 bibr14-09544119JEIM537 bibr45-09544119JEIM537 Nordin C. C. (bibr18-09544119JEIM537) 1998 bibr21-09544119JEIM537 bibr48-09544119JEIM537 bibr39-09544119JEIM537 bibr33-09544119JEIM537 bibr27-09544119JEIM537 Pheasant S. (bibr25-09544119JEIM537) 1996 bibr15-09544119JEIM537 Parnianpour M. (bibr34-09544119JEIM537) 2006 bibr12-09544119JEIM537 bibr8-09544119JEIM537 bibr44-09544119JEIM537 bibr13-09544119JEIM537 Parnianpour M. (bibr35-09544119JEIM537) 1999 bibr16-09544119JEIM537 bibr10-09544119JEIM537 bibr19-09544119JEIM537 bibr41-09544119JEIM537 bibr47-09544119JEIM537 bibr7-09544119JEIM537 bibr23-09544119JEIM537 Parnianpour M. (bibr22-09544119JEIM537) 1989; 49 bibr6-09544119JEIM537 bibr20-09544119JEIM537 bibr29-09544119JEIM537 Parnianpour M. (bibr36-09544119JEIM537) 1993 bibr17-09544119JEIM537 bibr40-09544119JEIM537 bibr9-09544119JEIM537 bibr4-09544119JEIM537 bibr1-09544119JEIM537 Weir J. P. (bibr30-09544119JEIM537) 2005; 19 Craig J. J. (bibr26-09544119JEIM537) 1989 bibr46-09544119JEIM537 bibr49-09544119JEIM537 bibr37-09544119JEIM537 Manchikanti L. (bibr3-09544119JEIM537) 2000; 3 bibr43-09544119JEIM537 |
References_xml | – volume: 40 start-page: S155 issue: Suppl. 2 year: 2007 article-title: ‘A new apparatus for triaxial measurement of lumbar moments in isometric mode.’ publication-title: J. Biomech. – volume: 8 start-page: 247 year: 1998 end-page: 256 article-title: ‘Trunk muscle activities during asymmetric twisting motions.’ publication-title: J. Electromyography Kinesiology – volume: 17 start-page: 922 issue: 8 year: 1992 end-page: 926 article-title: ‘A prospective evaluation of preemployment screening methods for acute industrial back pain.’ publication-title: Spine – volume: 13 start-page: 982 year: 1988 end-page: 992 article-title: ‘The triaxial coupling of torque generation of trunk muscles during isometric exertions and the effect of fatiguing isoinertial movements on the motor output and movement patterns.’ publication-title: Spine – volume: 14 start-page: 927 issue: 9 year: 1989 end-page: 938 article-title: ‘Mechanical recruitment of low-back muscles, theoretical predictions and experimental validation.’ publication-title: Spine – volume: 3 start-page: 167 year: 2000 end-page: 192 article-title: ‘Epidemiology of low back pain.’ publication-title: Pain Physician – volume: 9 start-page: 141 year: 1987 end-page: 155 article-title: ‘Normative data for isostation B100.’ publication-title: J. Orthop. Sports Phys. Therapy – volume: 16 start-page: 80 issue: 1 year: 2001 end-page: 83 article-title: ‘A triaxial dynamometer to monitor lateral bending and axial rotation moments during static trunk extension efforts.’ publication-title: Clin. Biomech. – volume: 5 start-page: 529 year: 1980 end-page: 538 article-title: ‘Trunk strengths in attempted flexion, extension, and lateral bending in healthy subjects and patients with low-back disorders.’ publication-title: Spine – volume: 23 start-page: 2563 issue: 23 year: 1998 end-page: 2573 article-title: ‘Estimation of trunk muscle forces and spinal loads during fatiguing repetitive trunk exertions.’ publication-title: Spine – volume: 34 start-page: 555 year: 2006 end-page: 558 article-title: ‘Prevalence of low back pain and sickness absence: A ‘borderline’ study in Norway and Sweden.’ publication-title: Scand. J. Public Health – volume: 27 start-page: 126 year: 2007 end-page: 129 article-title: ‘Nonspecific low back pain in 5000 Iranian school-age children.’ publication-title: J. Pediat. Orthop. – volume: 18 start-page: 2480 issue: 16 year: 1994 end-page: 2490 article-title: ‘Isometric maximal and submaximal trunk extension at different flexed positions in standing triaxial torque output and EMG.’ publication-title: Spine – volume: 49 start-page: 148 issue: 2 year: 1989 end-page: 154 article-title: ‘Reproducibility of trunk isoinertial performances in the sagittal, coronal, and transverse planes.’ publication-title: Bull. Hosp. Jt Dis. Orthop. Inst. – volume: 34 issue: 5 year: 2009 article-title: ‘The effect of angle and level of exertion on trunk neuromuscular performance during multi directional isometric activities.’ publication-title: Spine – volume: 20 start-page: 1649 issue: 15 year: 1995 end-page: 1656 article-title: ‘Isometric and dynamic performances of the trunk and associated factors.’ publication-title: Spine – volume: 11 start-page: 387 issue: 4 year: 2007 end-page: 397 article-title: ‘Comorbidity of low back pain: Representative outcomes of a national health study in the Federal Republic of Germany.’ publication-title: Eur. J. Pain – volume: 15 start-page: 221 issue: 4 year: 2000 end-page: 227 article-title: ‘Factor structure of trunk performance data for healthy subjects.’ publication-title: Clin. Biomech. – volume: 23 start-page: 527 issue: 5 year: 2008 end-page: 535 article-title: ‘Capability and recruitment patterns of trunk during isometric uniaxial and biaxial upright exertion.’ publication-title: Clin. Biomech. – volume: 19 start-page: 2015 issue: 17 year: 1994 article-title: ‘Isometric maximal and submaximal trunk extension at different flexed positions in standing. Triaxial torque output and EMG.’ publication-title: Spine – volume: 3 start-page: 163 year: 1982 end-page: 170 article-title: ‘Trunk testing using a prototype Cybex II isokinetic dynamometer stabilization system.’ publication-title: J. Orthop. Sports Phys. Therapy – volume: 35 start-page: 543 issue: 4 year: 2002 end-page: 548 article-title: ‘ISB recommendation on definitions of joint coordinate system of various joints for the reporting of human joint motion — part I: Ankle, hip, and spine.’ publication-title: J. Biomech. – volume: 19 start-page: 231 issue: 1 year: 2005 end-page: 240 article-title: ‘Quantifying test—retest reliability using the intraclass correlation coefficient and the SEM.’ publication-title: J. Strength Conditioning Res. – volume: 18 start-page: 1829 issue: 13 year: 1993 end-page: 1838 article-title: ‘The effects of resistance level on muscle coordination patterns and movement profile during trunk extension.’ publication-title: Spine – volume: 40 start-page: S268 issue: Suppl. 2 year: 2007 article-title: ‘Finite element study of the interaction of spine, IAP and surrounding muscles.’ publication-title: J. Biomech. – volume: 12 start-page: 509 issue: 6 year: 1999 end-page: 518 article-title: ‘An electromyography-assisted model to estimate trunk muscle forces during fatiguing repetitive trunk exertions.’ publication-title: J. Spinal Disorders – volume: 11 start-page: 291 issue: 3 year: 2008 end-page: 299 article-title: ‘Relative efficiency of abdominal muscles in spine stability.’ publication-title: Comput. Meth. Biomech. Biomed. Engng – volume: 34 start-page: 513 issue: 12 year: 1973 end-page: 525 article-title: ‘A longitudinal study of low-back pain as associated with occupational weight lifting factors.’ publication-title: Am. Ind. Hyg. Assoc. J. – volume: 11 start-page: 811 issue: 6 year: 1993 end-page: 817 article-title: ‘Electromyographic studies of the lumbar trunk musculature during the generation of low-level trunk acceleration.’ publication-title: J. Orthop. Res. – volume: 34 start-page: 459 issue: 4 year: 1997 end-page: 469 article-title: ‘Modeling of functional trunk muscle performance: Interfacing ergonomics and spine rehabilitation in response to the ADA.’ publication-title: J. Rehabil. Res. – volume: 25 start-page: 3087 issue: 23 year: 2000 end-page: 3092 article-title: ‘Flexion and rotation of the trunk and lifting at work are risk factors for low back pain: Results of a prospective cohort study.’ publication-title: Spine – volume: 14 start-page: 409 issue: 4 year: 1989 end-page: 411 article-title: ‘A database of isoinertial trunk strength tests against three resistance levels in sagittal, frontal, and transverse planes in normal male subjects.’ publication-title: Spine – volume: 17 start-page: 103 year: 1996 end-page: 111 article-title: ‘Isolated planar trunk strengths measurement in normal: Part III — results and database.’ publication-title: Int. J. Ind. Ergonomics – volume: 8 start-page: 203 issue: 4 year: 1993 end-page: 209 article-title: ‘Relationships between preferred and maximum effect low-back motion.’ publication-title: Clin. Biomech. – ident: bibr41-09544119JEIM537 doi: 10.1016/0169-8141(95)00042-9 – ident: bibr27-09544119JEIM537 – ident: bibr44-09544119JEIM537 doi: 10.1097/00007632-199508000-00001 – volume: 49 start-page: 148 issue: 2 year: 1989 ident: bibr22-09544119JEIM537 publication-title: Bull. Hosp. Jt Dis. Orthop. Inst. – ident: bibr37-09544119JEIM537 doi: 10.1097/00007632-199409000-00027 – volume-title: Measurement of joint motion: a guide to goniometry, 2nd edition (1st Indian edition) year: 1998 ident: bibr18-09544119JEIM537 – ident: bibr46-09544119JEIM537 doi: 10.1097/00002517-199912000-00011 – ident: bibr33-09544119JEIM537 doi: 10.1080/0002889738506892 – ident: bibr40-09544119JEIM537 doi: 10.1002/jor.1100110606 – ident: bibr7-09544119JEIM537 – start-page: 205 volume-title: Back pain rehabilitation year: 1993 ident: bibr36-09544119JEIM537 – ident: bibr5-09544119JEIM537 – ident: bibr6-09544119JEIM537 – ident: bibr12-09544119JEIM537 doi: 10.2519/jospt.1982.3.4.164 – ident: bibr21-09544119JEIM537 doi: 10.1016/S0021-9290(01)00222-6 – ident: bibr9-09544119JEIM537 doi: 10.1097/00007632-200012010-00018 – ident: bibr14-09544119JEIM537 – ident: bibr28-09544119JEIM537 doi: 10.1097/00007632-199310000-00019 – ident: bibr13-09544119JEIM537 – ident: bibr15-09544119JEIM537 doi: 10.1016/S1050-6411(98)00011-X – ident: bibr17-09544119JEIM537 – ident: bibr8-09544119JEIM537 doi: 10.1097/BPO.0b013e3180317a35 – ident: bibr16-09544119JEIM537 doi: 10.2519/jospt.1987.9.4.141 – volume-title: Introduction to robotics: mechanics and control, 2nd edition year: 1989 ident: bibr26-09544119JEIM537 – volume-title: Bodyspace: anthropometry, ergonomics and the design of the work, 2nd edition year: 1996 ident: bibr25-09544119JEIM537 – ident: bibr1-09544119JEIM537 – ident: bibr19-09544119JEIM537 doi: 10.1097/00007632-198809000-00004 – ident: bibr43-09544119JEIM537 doi: 10.1016/0268-0033(93)90015-A – ident: bibr4-09544119JEIM537 doi: 10.1016/j.ejpain.2006.05.005 – start-page: 985 volume-title: Occupational ergonomics handbook year: 1999 ident: bibr35-09544119JEIM537 – ident: bibr2-09544119JEIM537 doi: 10.1080/14034940600552051 – ident: bibr20-09544119JEIM537 doi: 10.1097/00007632-198011000-00008 – ident: bibr47-09544119JEIM537 doi: 10.1016/S0021-9290(07)70264-6 – ident: bibr32-09544119JEIM537 doi: 10.1097/00007632-199208000-00009 – volume-title: Amirkabir J. Sci. Technol. year: 2009 ident: bibr24-09544119JEIM537 – volume: 19 start-page: 231 issue: 1 year: 2005 ident: bibr30-09544119JEIM537 publication-title: J. Strength Conditioning Res. – ident: bibr48-09544119JEIM537 doi: 10.1080/10255840802020404 – ident: bibr23-09544119JEIM537 doi: 10.1016/S0021-9290(07)70151-3 – ident: bibr45-09544119JEIM537 doi: 10.1097/00007632-199812010-00011 – ident: bibr49-09544119JEIM537 doi: 10.1097/00007632-198909000-00004 – ident: bibr39-09544119JEIM537 doi: 10.1016/j.clinbiomech.2007.11.017 – ident: bibr10-09544119JEIM537 doi: 10.1016/S0268-0033(00)00068-1 – ident: bibr42-09544119JEIM537 doi: 10.1097/00007632-198904000-00012 – start-page: 83-1 volume-title: Biomedical engineering fundamentals year: 2006 ident: bibr34-09544119JEIM537 – ident: bibr29-09544119JEIM537 doi: 10.1097/00007632-199312000-00018 – ident: bibr11-09544119JEIM537 doi: 10.1016/S0268-0033(99)00078-9 – ident: bibr38-09544119JEIM537 doi: 10.1097/BRS.0b013e31818aec05 – volume: 34 start-page: 459 issue: 4 year: 1997 ident: bibr31-09544119JEIM537 publication-title: J. Rehabil. Res. – volume: 3 start-page: 167 year: 2000 ident: bibr3-09544119JEIM537 publication-title: Pain Physician doi: 10.36076/ppj.2000/3/167 |
SSID | ssj0001106 |
Score | 1.9928122 |
Snippet | Abstract
Maximal strength measurements of the trunk have been used to evaluate the maximum functional capacity of muscles and the potential mechanical overload... Maximal strength measurements of the trunk have been used to evaluate the maximum functional capacity of muscles and the potential mechanical overload or... Abstract Maximal strength measurements of the trunk have been used to evaluate the maximum functional capacity of muscles and the potential mechanical overload... |
SourceID | proquest pubmed crossref sage |
SourceType | Aggregation Database Index Database Enrichment Source Publisher |
StartPage | 755 |
SubjectTerms | Anthropometry Asymmetry Back - physiology Bend strength Biomechanics Calibration Coefficients Computer-Aided Design Design analysis Dynamical systems Equipment Design Equipment Failure Analysis Error analysis Evaluation Fatigue tests Functional anatomy Health risks Human mechanics Humans Injuries Isometric Contraction - physiology Least squares method Mathematical models Measurement Muscle contraction Muscle Contraction - physiology Muscle strength Muscle Strength - physiology Muscle Strength Dynamometer Muscle, Skeletal - physiology Muscles Muscular system Optimization Regression analysis Reliability Reliability analysis Reproducibility of Results Risk Sensitivity and Specificity Sensors Spine Spine (lumbar) Symmetry Thorax - physiology Tissues Torque Transducers Trunk muscles Variability |
Title | Design and evaluation of a novel triaxial isometric trunk muscle strength measurement system |
URI | https://journals.sagepub.com/doi/full/10.1243/09544119JEIM537 https://www.ncbi.nlm.nih.gov/pubmed/19743641 https://www.proquest.com/docview/1904263895 https://www.proquest.com/docview/236475063 https://www.proquest.com/docview/35144638 https://www.proquest.com/docview/67646450 https://www.proquest.com/docview/771852812 |
Volume | 223 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwfV1LT9wwEB4VkKpyqCh9kEK3PrRSLyl5OHF8qnjsQpEWVVWR9lApcmynINgElN2qP78zifdRYHvJwXYS2xl7vsmMvwH4EJlMGBlIP4sK7fOiKHwiAaeLzlBdWd26Yobn6ekFPxslIxeb07iwytme2G7Uptb0j3y_JTpPUKF-ub3zKWkUOVddBo012AhR0ZCYZ4OT-UaMmi3tqPa4z8NQOmafiMf7VEZFZ_2vw4RyoC8rpQdI858or1bxDLbguUOM7KD7xC_gia22YXOJR3Abng6dh_wl_DxuQzKYqgxbMHmzumSKVfVve8MoT8cflDp21dRjyqelsWhaXbPxtMEXMDo9Uv2aXLLx4vch6wifX8HFoP_j6NR3GRR8nUTBxBcy0rGKA23RkLNaoLViuUYLTepY2kDpEhFDlMSFSdNSoj5DtBeHOixVWCBOsfFrWK_qyu4Ak5lURpWR4sJyw2VWGLQkbRkYpTIEJR58nk1hrh29OGW5uMnJzMA5z-_NuQef5jfcdswaq5vuzb5J7pZYkyOSIbL5TOKrdx9Wz-XFg_fzWlw65A9Rla2nTU6HGDg-YXWLVKTk-Q08YCtaCEGnzxElefCmE5bFYNBUw06EHnwk6Vnq-eOjfPvfYezCs86RRbGHe7COkmHfIR6aFD1YEyPRa2W_BxuH_fNv3_8CCO4Gxw |
linkProvider | ProQuest |
linkToHtml | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwtV1Lb9QwEB6VrcTjgKC8Qgv1gUpcQhPHefiAENCtdtvuCqFW6gEpdWwHEN2kKLs8fhT_kZk8dhfKcuslB9vxc-yZ8Xi-AXjGTRIb6Uk34Zl2RZZlLoGA00cnyK6srk0xo3E0OBEHp-HpGvzqfGHoWWV3JtYHtSk13ZHv1kDnITLUVxdfXQoaRcbVLoJGQxWH9ud31Niql8M9XN4dzvf7x28HbhtUwNUh96ZuLLkOVOBpi7qN1TEK8FZoVFqkDqT1lM6RifIwyEwU5RKPeBSAAl_7ufIzZN02wHqvwbogh9YerL_pj9-9nx_9yEujBtxPuML3ZYslxEWwS2mUdNAfjkKKur7MBi_Jtn-8K6tZ3f4duN3KqOx1Q1R3Yc0WG3BrCblwA66PWpv8PfiwVz8CYaowbIEdzsqcKVaU3-w5o8ggP5DO2eeqnFAEL41Js-ILm8wqbICRv0rxcfqJTRYXlqyBmL4PJ1cyvQ-gV5SFfQRMJlIZlXMlYiuMkElmUHe1uWeUSlAMcuBFN4WpbgHNKa7GeUqKDc55-tecO_B8_sNFg-WxuuhWtyZpu6mrFGUngrdPJDa9eTl7TqEObM9zcbOSBUYVtpxVKblNCKxhdYkojsjW7DnAVpSIY_J3R7nMgYcNsSwGg8ohdsJ3YIeoZ6nn_x7l4_8OYxtuDI5HR-nRcHy4CTcbMxq9fNyCHlKJfYLS2DR72u4BBmdXve1-Aws5QS8 |
linkToPdf | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwtV1Lb9QwEB6VIlX0gEp5NLRQH6jEJWziOA8fKlSxXXVbtuJApT0gBcd2ANFNirLL46f13zGTx-5CWW695OA4Dzsznm8y428AXnCTxEZ60k14pl2RZZlLJOB00AmaK6vrUMzoPDq5EKfjcLwG191eGEqr7NbEeqE2paZ_5L2a6DxEg9rL26yId_3B66tvLhWQokBrV02jkZAz--sHem_V4bCPn_qA88Hx-zcnbltgwNUh96ZuLLkOVOBpi36O1TGCeSs0OjBSB9J6SudoUHkYZCaKconLPYKhwNd-rvwMzbgN8L534G4cIKhCVYrHc1-PrGrU0PwJV_i-bFmFuAh61EZNp8fDUUj115cN4g2U-0eGWW30Bltwv0Wr7KgRrwewZott2FziMNyGjVEbnX8IH_p1OghThWELFnFW5kyxovxuLxnVCPmJEs--VOWEanlpbJoVX9lkVuEDGO1cKT5NP7PJ4tcla8imH8HFrUzuY1gvysLuAJOJVEblXInYCiNkkhn0Ym3uGaUSBEQOvOqmMNUttTlV2LhMycXBOU__mnMHXs4vuGpYPVZ33eu-Sdqqd5UiiiKi-0Tio3dvnp7LqgP787OothSLUYUtZ1VKGygE3mF1jyiOKOrsOcBW9Ihj2vmOCM2BJ42wLAaDbiK-hO_AAUnP0pv_e5RP_zuMfdhAZUvfDs_PduFeE0-jFMg9WEchsc8Qlk2z57UCMPh42xr3G5uVQ_Y |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Design+and+evaluation+of+a+novel+triaxial+isometric+trunk+muscle+strength+measurement+system&rft.jtitle=Proceedings+of+the+Institution+of+Mechanical+Engineers.+Part+H%2C+Journal+of+engineering+in+medicine&rft.au=Azghani%2C+M+R&rft.au=Farahmand%2C+F&rft.au=Meghdari%2C+A&rft.au=Vossoughi%2C+G&rft.date=2009-08-01&rft.issn=0954-4119&rft.eissn=2041-3033&rft.volume=223&rft.issue=6&rft.spage=755&rft.epage=766&rft_id=info:doi/10.1243%2F09544119JEIM537&rft.externalDBID=n%2Fa&rft.externalDocID=10_1243_09544119JEIM537 |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0954-4119&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0954-4119&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0954-4119&client=summon |