Volumetric navigators for prospective motion correction and selective reacquisition in neuroanatomical MRI

We introduce a novel method of prospectively compensating for subject motion in neuroanatomical imaging. Short three‐dimensional echo‐planar imaging volumetric navigators are embedded in a long three‐dimensional sequence, and the resulting image volumes are registered to provide an estimate of the s...

Full description

Saved in:
Bibliographic Details
Published inMagnetic resonance in medicine Vol. 68; no. 2; pp. 389 - 399
Main Authors Tisdall, M. Dylan, Hess, Aaron T., Reuter, Martin, Meintjes, Ernesta M., Fischl, Bruce, van der Kouwe, André J. W.
Format Journal Article
LanguageEnglish
Published Hoboken Wiley Subscription Services, Inc., A Wiley Company 01.08.2012
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:We introduce a novel method of prospectively compensating for subject motion in neuroanatomical imaging. Short three‐dimensional echo‐planar imaging volumetric navigators are embedded in a long three‐dimensional sequence, and the resulting image volumes are registered to provide an estimate of the subject's location in the scanner at a cost of less than 500 ms, ∼ 1% change in contrast, and ∼3% change in intensity. This time fits well into the existing gaps in sequences routinely used for neuroimaging, thus giving a motion‐corrected sequence with no extra time required. We also demonstrate motion‐driven selective reacquisition of k‐space to further compensate for subject motion. We perform multiple validation experiments to evaluate accuracy, navigator impact on tissue intensity/contrast, and the improvement in final output. The complete system operates without adding additional hardware to the scanner and requires no external calibration, making it suitable for high‐throughput environments. Magn Reson Med, 2012. © 2011 Wiley Periodicals, Inc.
Bibliography:ArticleID:MRM23228
NCRR Shared Instrumentation Grant Program and/or High-End Instrumentation Grant Program - No. S10RR021110; No. S10RR023401
NIH - No. 5R21EB008547; No. 5R21AA017410; No. 5R21DA026104; No. 5R01NS055754
ark:/67375/WNG-GCTZ5QGF-J
Center for Functional Neuroimaging Technologies - No. P41RR14075 [a P41 Regional Resource supported by Biomedical Technology Program of the National Center for Research Resources (NCRR), National Institutes of Health]
Ellison Medical Foundation
istex:1F794E3A1A1942E3E68C580E4A9D04F9D098EEA4
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0740-3194
1522-2594
1522-2594
DOI:10.1002/mrm.23228