Comparative assessment of heel rise detection for consistent gait phase separation

Accurate identification of gait events is crucial to reliable gait analysis. Heel rise, a key event marking the transition from mid-stance to terminal stance, poses challenges in precise detection due to its gradual nature. This leads to variability in accuracy across studies utilizing diverse measu...

Full description

Saved in:
Bibliographic Details
Published inHeliyon Vol. 10; no. 13; p. e33546
Main Authors Salminen, Mikko, Perttunen, Jarmo, Avela, Janne, Vehkaoja, Antti
Format Journal Article
LanguageEnglish
Published England Elsevier Ltd 15.07.2024
Elsevier
Subjects
Online AccessGet full text
ISSN2405-8440
2405-8440
DOI10.1016/j.heliyon.2024.e33546

Cover

Loading…
Abstract Accurate identification of gait events is crucial to reliable gait analysis. Heel rise, a key event marking the transition from mid-stance to terminal stance, poses challenges in precise detection due to its gradual nature. This leads to variability in accuracy across studies utilizing diverse measuring techniques. How do different HR detection methods compare when assessed against the underlying heel motion pattern and visual detection across varying speed, footwear conditions, and individuals? Leveraging data from over 10,000 strides in diverse scenarios with 15 healthy subjects, we evaluated methods based on measurements from optical motion capture (OMC), force plates, and shank-mounted inertial measurement units (IMUs). The evaluation of these methods included an assessment of their precision and consistency with the heel marker's motion pattern and agreement with visually detected heel rise. OMC-based heel rise detection methods, utilizing the heel marker's vertical acceleration and jerk, consistently identified the same point in the heel motion pattern, outperforming velocity-based methods and our new position-based method resembling traditional footswitch-based heel rise detection. Variability in velocity and position-based methods derives from subtle heel rise variations after mid-stance, exhibiting individual differences. Our proposed IMU-based methods show promise by closely matching OMC-based accuracy. The results have significant implications for gait analysis, providing insights into heel rise event detection's complexities. Accurate HR identification is crucial for gait phase separation, and our findings, especially with the robust heel marker's jerk-based method, enhance precision and consistency across walking conditions. Moreover, our successful development and validation of IMU-based algorithm offer cost-effective and mobile alternative for HR detection, expanding their potential use in comprehensive gait analysis. •We assess motion capture, force plate, and IMU data to identify the most precise heel rise detection method.•Subtle rising of the heel before the actual lift-off causes variability in heel rise detection.•Heel marker's acceleration and jerk-based methods are in high agreement with visual detection.•Novel IMU-based methods closely mirror the performance of acceleration and jerk-based methods.•The proposed methods improve heel rise detection accuracy for gait analysis.
AbstractList Background: Accurate identification of gait events is crucial to reliable gait analysis. Heel rise, a key event marking the transition from mid-stance to terminal stance, poses challenges in precise detection due to its gradual nature. This leads to variability in accuracy across studies utilizing diverse measuring techniques. Research question: How do different HR detection methods compare when assessed against the underlying heel motion pattern and visual detection across varying speed, footwear conditions, and individuals? Methods: Leveraging data from over 10,000 strides in diverse scenarios with 15 healthy subjects, we evaluated methods based on measurements from optical motion capture (OMC), force plates, and shank-mounted inertial measurement units (IMUs). The evaluation of these methods included an assessment of their precision and consistency with the heel marker's motion pattern and agreement with visually detected heel rise. Results: OMC-based heel rise detection methods, utilizing the heel marker's vertical acceleration and jerk, consistently identified the same point in the heel motion pattern, outperforming velocity-based methods and our new position-based method resembling traditional footswitch-based heel rise detection. Variability in velocity and position-based methods derives from subtle heel rise variations after mid-stance, exhibiting individual differences. Our proposed IMU-based methods show promise by closely matching OMC-based accuracy. Significance: The results have significant implications for gait analysis, providing insights into heel rise event detection's complexities. Accurate HR identification is crucial for gait phase separation, and our findings, especially with the robust heel marker's jerk-based method, enhance precision and consistency across walking conditions. Moreover, our successful development and validation of IMU-based algorithm offer cost-effective and mobile alternative for HR detection, expanding their potential use in comprehensive gait analysis.
Accurate identification of gait events is crucial to reliable gait analysis. Heel rise, a key event marking the transition from mid-stance to terminal stance, poses challenges in precise detection due to its gradual nature. This leads to variability in accuracy across studies utilizing diverse measuring techniques. How do different HR detection methods compare when assessed against the underlying heel motion pattern and visual detection across varying speed, footwear conditions, and individuals? Leveraging data from over 10,000 strides in diverse scenarios with 15 healthy subjects, we evaluated methods based on measurements from optical motion capture (OMC), force plates, and shank-mounted inertial measurement units (IMUs). The evaluation of these methods included an assessment of their precision and consistency with the heel marker's motion pattern and agreement with visually detected heel rise. OMC-based heel rise detection methods, utilizing the heel marker's vertical acceleration and jerk, consistently identified the same point in the heel motion pattern, outperforming velocity-based methods and our new position-based method resembling traditional footswitch-based heel rise detection. Variability in velocity and position-based methods derives from subtle heel rise variations after mid-stance, exhibiting individual differences. Our proposed IMU-based methods show promise by closely matching OMC-based accuracy. The results have significant implications for gait analysis, providing insights into heel rise event detection's complexities. Accurate HR identification is crucial for gait phase separation, and our findings, especially with the robust heel marker's jerk-based method, enhance precision and consistency across walking conditions. Moreover, our successful development and validation of IMU-based algorithm offer cost-effective and mobile alternative for HR detection, expanding their potential use in comprehensive gait analysis. •We assess motion capture, force plate, and IMU data to identify the most precise heel rise detection method.•Subtle rising of the heel before the actual lift-off causes variability in heel rise detection.•Heel marker's acceleration and jerk-based methods are in high agreement with visual detection.•Novel IMU-based methods closely mirror the performance of acceleration and jerk-based methods.•The proposed methods improve heel rise detection accuracy for gait analysis.
Accurate identification of gait events is crucial to reliable gait analysis. Heel rise, a key event marking the transition from mid-stance to terminal stance, poses challenges in precise detection due to its gradual nature. This leads to variability in accuracy across studies utilizing diverse measuring techniques. How do different HR detection methods compare when assessed against the underlying heel motion pattern and visual detection across varying speed, footwear conditions, and individuals? Leveraging data from over 10,000 strides in diverse scenarios with 15 healthy subjects, we evaluated methods based on measurements from optical motion capture (OMC), force plates, and shank-mounted inertial measurement units (IMUs). The evaluation of these methods included an assessment of their precision and consistency with the heel marker's motion pattern and agreement with visually detected heel rise. OMC-based heel rise detection methods, utilizing the heel marker's vertical acceleration and jerk, consistently identified the same point in the heel motion pattern, outperforming velocity-based methods and our new position-based method resembling traditional footswitch-based heel rise detection. Variability in velocity and position-based methods derives from subtle heel rise variations after mid-stance, exhibiting individual differences. Our proposed IMU-based methods show promise by closely matching OMC-based accuracy. The results have significant implications for gait analysis, providing insights into heel rise event detection's complexities. Accurate HR identification is crucial for gait phase separation, and our findings, especially with the robust heel marker's jerk-based method, enhance precision and consistency across walking conditions. Moreover, our successful development and validation of IMU-based algorithm offer cost-effective and mobile alternative for HR detection, expanding their potential use in comprehensive gait analysis.
Accurate identification of gait events is crucial to reliable gait analysis. Heel rise, a key event marking the transition from mid-stance to terminal stance, poses challenges in precise detection due to its gradual nature. This leads to variability in accuracy across studies utilizing diverse measuring techniques. How do different HR detection methods compare when assessed against the underlying heel motion pattern and visual detection across varying speed, footwear conditions, and individuals? Leveraging data from over 10,000 strides in diverse scenarios with 15 healthy subjects, we evaluated methods based on measurements from optical motion capture (OMC), force plates, and shank-mounted inertial measurement units (IMUs). The evaluation of these methods included an assessment of their precision and consistency with the heel marker's motion pattern and agreement with visually detected heel rise. OMC-based heel rise detection methods, utilizing the heel marker's vertical acceleration and jerk, consistently identified the same point in the heel motion pattern, outperforming velocity-based methods and our new position-based method resembling traditional footswitch-based heel rise detection. Variability in velocity and position-based methods derives from subtle heel rise variations after mid-stance, exhibiting individual differences. Our proposed IMU-based methods show promise by closely matching OMC-based accuracy. The results have significant implications for gait analysis, providing insights into heel rise event detection's complexities. Accurate HR identification is crucial for gait phase separation, and our findings, especially with the robust heel marker's jerk-based method, enhance precision and consistency across walking conditions. Moreover, our successful development and validation of IMU-based algorithm offer cost-effective and mobile alternative for HR detection, expanding their potential use in comprehensive gait analysis.
Accurate identification of gait events is crucial to reliable gait analysis. Heel rise, a key event marking the transition from mid-stance to terminal stance, poses challenges in precise detection due to its gradual nature. This leads to variability in accuracy across studies utilizing diverse measuring techniques.BackgroundAccurate identification of gait events is crucial to reliable gait analysis. Heel rise, a key event marking the transition from mid-stance to terminal stance, poses challenges in precise detection due to its gradual nature. This leads to variability in accuracy across studies utilizing diverse measuring techniques.How do different HR detection methods compare when assessed against the underlying heel motion pattern and visual detection across varying speed, footwear conditions, and individuals?Research questionHow do different HR detection methods compare when assessed against the underlying heel motion pattern and visual detection across varying speed, footwear conditions, and individuals?Leveraging data from over 10,000 strides in diverse scenarios with 15 healthy subjects, we evaluated methods based on measurements from optical motion capture (OMC), force plates, and shank-mounted inertial measurement units (IMUs). The evaluation of these methods included an assessment of their precision and consistency with the heel marker's motion pattern and agreement with visually detected heel rise.MethodsLeveraging data from over 10,000 strides in diverse scenarios with 15 healthy subjects, we evaluated methods based on measurements from optical motion capture (OMC), force plates, and shank-mounted inertial measurement units (IMUs). The evaluation of these methods included an assessment of their precision and consistency with the heel marker's motion pattern and agreement with visually detected heel rise.OMC-based heel rise detection methods, utilizing the heel marker's vertical acceleration and jerk, consistently identified the same point in the heel motion pattern, outperforming velocity-based methods and our new position-based method resembling traditional footswitch-based heel rise detection. Variability in velocity and position-based methods derives from subtle heel rise variations after mid-stance, exhibiting individual differences. Our proposed IMU-based methods show promise by closely matching OMC-based accuracy.ResultsOMC-based heel rise detection methods, utilizing the heel marker's vertical acceleration and jerk, consistently identified the same point in the heel motion pattern, outperforming velocity-based methods and our new position-based method resembling traditional footswitch-based heel rise detection. Variability in velocity and position-based methods derives from subtle heel rise variations after mid-stance, exhibiting individual differences. Our proposed IMU-based methods show promise by closely matching OMC-based accuracy.The results have significant implications for gait analysis, providing insights into heel rise event detection's complexities. Accurate HR identification is crucial for gait phase separation, and our findings, especially with the robust heel marker's jerk-based method, enhance precision and consistency across walking conditions. Moreover, our successful development and validation of IMU-based algorithm offer cost-effective and mobile alternative for HR detection, expanding their potential use in comprehensive gait analysis.SignificanceThe results have significant implications for gait analysis, providing insights into heel rise event detection's complexities. Accurate HR identification is crucial for gait phase separation, and our findings, especially with the robust heel marker's jerk-based method, enhance precision and consistency across walking conditions. Moreover, our successful development and validation of IMU-based algorithm offer cost-effective and mobile alternative for HR detection, expanding their potential use in comprehensive gait analysis.
• We assess motion capture, force plate, and IMU data to identify the most precise heel rise detection method. • Subtle rising of the heel before the actual lift-off causes variability in heel rise detection. • Heel marker's acceleration and jerk-based methods are in high agreement with visual detection. • Novel IMU-based methods closely mirror the performance of acceleration and jerk-based methods. • The proposed methods improve heel rise detection accuracy for gait analysis.
ArticleNumber e33546
Author Avela, Janne
Perttunen, Jarmo
Vehkaoja, Antti
Salminen, Mikko
Author_xml – sequence: 1
  givenname: Mikko
  surname: Salminen
  fullname: Salminen, Mikko
  organization: Faculty of Medicine and Health Technology, Tampere University, Korkeakoulunkatu 3, 33720, Tampere, Finland
– sequence: 2
  givenname: Jarmo
  surname: Perttunen
  fullname: Perttunen, Jarmo
  organization: Faculty of Sports and Health Sciences, Jyväskylä University, Seminaarinkatu 15, 40014, Jyväskylä, Finland
– sequence: 3
  givenname: Janne
  surname: Avela
  fullname: Avela, Janne
  organization: Faculty of Sports and Health Sciences, Jyväskylä University, Seminaarinkatu 15, 40014, Jyväskylä, Finland
– sequence: 4
  givenname: Antti
  orcidid: 0000-0003-3721-3467
  surname: Vehkaoja
  fullname: Vehkaoja, Antti
  email: antti.vehkaoja@tuni.fi
  organization: Faculty of Medicine and Health Technology, Tampere University, Korkeakoulunkatu 3, 33720, Tampere, Finland
BackLink https://www.ncbi.nlm.nih.gov/pubmed/39040320$$D View this record in MEDLINE/PubMed
BookMark eNqFkk1vGyEQhlGVqknT_IRWe-zF7gALC6eqsvoRKVKlqj0jzA421i64sLaUf1_cddPklBMIHj3MMO9rchFTRELeUlhSoPLDbrnFIdynuGTA2iVyLlr5glyxFsRCtS1cPNpfkptSdgBAhZK646_IJdfQAmdwRX6s0ri32U7hiI0tBUsZMU5N8s0WcWhyKNj0OKGbQoqNT7lxKZZQphO1sWFq9ltbmYKzJsU35KW3Q8Gb83pNfn35_HP1bXH3_evt6tPdwgkqpkUvwa475XlnrYROSEr7VruO6V5p5rn0zjNwglkKjHulqVO-5et1q8CBBH5Nbmdvn-zO7HMYbb43yQbz9yDljbF5Cm5Ao5TjHqpKMNZ2zCmlJBeUK8p71Kqvro-za39Yj9i72ly2wxPp05sYtmaTjoZSJkGrUzXvz4acfh-wTGYMxeEw2IjpUAynoj5HFdDnUVBcVqXWFX33uK6Hgv4NsAJiBlxOpWT0DwgFc8qK2ZlzVswpK2bOyv-GsU7oGDCb4gJGh33Iddb1C8Mzhj-Oyskp
Cites_doi 10.3390/s22103859
10.1016/j.gaitpost.2003.10.001
10.1109/TNSRE.2019.2950309
10.1080/00140130701582104
10.1016/j.jbiomech.2017.02.016
10.1016/j.gaitpost.2024.04.006
10.1080/00140139.2016.1174314
10.1080/17434440.2016.1198694
10.1177/096228029900800204
10.1063/5.0056893
10.1037/1082-989X.1.1.30
10.1016/j.jbiomech.2015.12.035
10.1016/j.gaitpost.2012.07.012
10.1007/s11517-010-0692-0
10.3390/s17040671
10.5507/ag.2015.022
10.1186/1743-0003-11-152
10.1016/j.medengphy.2015.01.001
10.3390/s21082727
ContentType Journal Article
Copyright 2024 The Authors
2024 The Authors.
2024 The Authors 2024
Copyright_xml – notice: 2024 The Authors
– notice: 2024 The Authors.
– notice: 2024 The Authors 2024
DBID 6I.
AAFTH
AAYXX
CITATION
NPM
7X8
7S9
L.6
5PM
DOA
DOI 10.1016/j.heliyon.2024.e33546
DatabaseName ScienceDirect Open Access Titles
Elsevier:ScienceDirect:Open Access
CrossRef
PubMed
MEDLINE - Academic
AGRICOLA
AGRICOLA - Academic
PubMed Central (Full Participant titles)
DOAJ Directory of Open Access Journals
DatabaseTitle CrossRef
PubMed
MEDLINE - Academic
AGRICOLA
AGRICOLA - Academic
DatabaseTitleList

AGRICOLA
PubMed
MEDLINE - Academic

Database_xml – sequence: 1
  dbid: DOA
  name: DOAJ Directory of Open Access Journals
  url: https://www.doaj.org/
  sourceTypes: Open Website
– sequence: 2
  dbid: NPM
  name: PubMed
  url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed
  sourceTypes: Index Database
DeliveryMethod fulltext_linktorsrc
Discipline Medicine
EISSN 2405-8440
ExternalDocumentID oai_doaj_org_article_88c3f052a522472c88863513813de98d
PMC11260980
39040320
10_1016_j_heliyon_2024_e33546
S240584402409577X
Genre Journal Article
GroupedDBID 0R~
457
53G
5VS
6I.
AAEDW
AAFTH
AAFWJ
AALRI
AAYWO
ABMAC
ACGFS
ACLIJ
ACVFH
ADBBV
ADCNI
ADEZE
ADVLN
AEUPX
AEXQZ
AFJKZ
AFPKN
AFPUW
AFTJW
AGHFR
AIGII
AITUG
AKBMS
AKRWK
AKYEP
ALMA_UNASSIGNED_HOLDINGS
AMRAJ
AOIJS
APXCP
BAWUL
BCNDV
DIK
EBS
FDB
GROUPED_DOAJ
HYE
KQ8
M~E
O9-
OK1
ROL
RPM
SSZ
AAYXX
CITATION
EJD
IPNFZ
RIG
NPM
7X8
7S9
L.6
5PM
ID FETCH-LOGICAL-c515t-d60ab78f37aa6075611d49c729d892f36fcf20c52a1023f891c8f43bb480c0603
IEDL.DBID DOA
ISSN 2405-8440
IngestDate Wed Aug 27 01:29:32 EDT 2025
Thu Aug 21 18:32:51 EDT 2025
Fri Aug 22 20:27:29 EDT 2025
Fri Jul 11 03:57:17 EDT 2025
Mon Jul 21 06:04:22 EDT 2025
Wed Aug 27 16:27:34 EDT 2025
Sat Sep 06 17:16:03 EDT 2025
IsDoiOpenAccess true
IsOpenAccess true
IsPeerReviewed true
IsScholarly true
Issue 13
Keywords Inertial measurement unit (IMU)
Optical motion capture
Event detection
Shank angular velocity
Heel-off
Gait analysis
Language English
License This is an open access article under the CC BY license.
2024 The Authors.
This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
LinkModel DirectLink
MergedId FETCHMERGED-LOGICAL-c515t-d60ab78f37aa6075611d49c729d892f36fcf20c52a1023f891c8f43bb480c0603
Notes ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ORCID 0000-0003-3721-3467
OpenAccessLink https://doaj.org/article/88c3f052a522472c88863513813de98d
PMID 39040320
PQID 3083680399
PQPubID 23479
ParticipantIDs doaj_primary_oai_doaj_org_article_88c3f052a522472c88863513813de98d
pubmedcentral_primary_oai_pubmedcentral_nih_gov_11260980
proquest_miscellaneous_3153811801
proquest_miscellaneous_3083680399
pubmed_primary_39040320
crossref_primary_10_1016_j_heliyon_2024_e33546
elsevier_sciencedirect_doi_10_1016_j_heliyon_2024_e33546
PublicationCentury 2000
PublicationDate 2024-07-15
PublicationDateYYYYMMDD 2024-07-15
PublicationDate_xml – month: 07
  year: 2024
  text: 2024-07-15
  day: 15
PublicationDecade 2020
PublicationPlace England
PublicationPlace_xml – name: England
PublicationTitle Heliyon
PublicationTitleAlternate Heliyon
PublicationYear 2024
Publisher Elsevier Ltd
Elsevier
Publisher_xml – name: Elsevier Ltd
– name: Elsevier
References Maqbool, Husman, Awad, Abouhossein, Mehryar, Iqbal, Dehghani-Sanij (bib18) 2016
Salminen, Perttunen, Avela, Vehkaoja (bib10) 2024; 111
Kim, Lee (bib15) 2017; 60
Mariani, Rouhani, Crevoisier, Aminian (bib19) 2013; 37
Prasanth, Caban, Keller, Courtine, Ijspeert, Vallery, von Zitzewitz (bib3) 2021; 21
Winter (bib1) 2009
Vaverka, Elfmark, Svoboda, Janura (bib22) 2015; 45
Whittle (bib4) 2007
Lambrecht, Harutyunyan, Tanghe, Afschrift, De Schutter, Jonkers (bib16) 2017; 17
Liu, Zhang, Yao, Yu, Wang, Fan (bib17) 2021; 92
Trojaniello, Cereatti, Pelosin, Avanzino, Mirelman, Hausdorff, Della Croce (bib11) 2014; 11
Bötzel, Marti, Rodríguez, Plate, Vicente (bib7) 2016; 49
Bland, Altman (bib24) 1999; 8
Cikajlo, Matjačić (bib12) 2007; 50
Pappas, Popovic, Keller, Dietz, Morari (bib20) 2001; 9
Tanghe, De Groote, Lefeber, De Schutter, Aertbelien (bib21) 2020; 28
Salminen (bib23) 2023
Iosa, Picerno, Paolucci, Morone (bib2) 2016; 13
Allseits, Lucarevic, Gailey, Agrawal, Gaunaurd, Bennett (bib6) 2017; 55
Perry, Burnfield (bib5) 2010
Greene, Mcgrath, O'Neill, O'Donovan, Burns, Caulfield (bib8) 2010; 48
Ghoussayni, Stevens, Durham, Ewins (bib14) 2004; 20
Romijnders, Warmerdam, Hansen, Schmidt, Maetzler (bib9) 2022; 22
Mcgraw, Wong (bib25) 1996; 1
Boutaayamou, Schwartz, Stamatakis, Denoël, Maquet, Forthomme, Croisier, Macq, Verly, Garraux, Brüls (bib13) 2015; 37
Mcgraw (10.1016/j.heliyon.2024.e33546_bib25) 1996; 1
Liu (10.1016/j.heliyon.2024.e33546_bib17) 2021; 92
Bland (10.1016/j.heliyon.2024.e33546_bib24) 1999; 8
Pappas (10.1016/j.heliyon.2024.e33546_bib20) 2001; 9
Romijnders (10.1016/j.heliyon.2024.e33546_bib9) 2022; 22
Trojaniello (10.1016/j.heliyon.2024.e33546_bib11) 2014; 11
Cikajlo (10.1016/j.heliyon.2024.e33546_bib12) 2007; 50
Salminen (10.1016/j.heliyon.2024.e33546_bib23) 2023
Bötzel (10.1016/j.heliyon.2024.e33546_bib7) 2016; 49
Kim (10.1016/j.heliyon.2024.e33546_bib15) 2017; 60
Perry (10.1016/j.heliyon.2024.e33546_bib5) 2010
Boutaayamou (10.1016/j.heliyon.2024.e33546_bib13) 2015; 37
Iosa (10.1016/j.heliyon.2024.e33546_bib2) 2016; 13
Maqbool (10.1016/j.heliyon.2024.e33546_bib18) 2016
Mariani (10.1016/j.heliyon.2024.e33546_bib19) 2013; 37
Prasanth (10.1016/j.heliyon.2024.e33546_bib3) 2021; 21
Winter (10.1016/j.heliyon.2024.e33546_bib1) 2009
Whittle (10.1016/j.heliyon.2024.e33546_bib4) 2007
Ghoussayni (10.1016/j.heliyon.2024.e33546_bib14) 2004; 20
Allseits (10.1016/j.heliyon.2024.e33546_bib6) 2017; 55
Lambrecht (10.1016/j.heliyon.2024.e33546_bib16) 2017; 17
Vaverka (10.1016/j.heliyon.2024.e33546_bib22) 2015; 45
Salminen (10.1016/j.heliyon.2024.e33546_bib10) 2024; 111
Greene (10.1016/j.heliyon.2024.e33546_bib8) 2010; 48
Tanghe (10.1016/j.heliyon.2024.e33546_bib21) 2020; 28
References_xml – year: 2010
  ident: bib5
  article-title: Gait Analysis : Normal and Pathological Function
– volume: 92
  year: 2021
  ident: bib17
  article-title: Gait phase detection based on inertial measurement unit and force-sensitive resistors embedded in a shoe
  publication-title: Rev. Sci. Instrum.
– volume: 1
  start-page: 30
  year: 1996
  end-page: 46
  ident: bib25
  article-title: Forming inferences about some intraclass correlation coefficients
  publication-title: Psychol. Methods
– year: 2023
  ident: bib23
  article-title: A heel rise event visual detection tool
  publication-title: Zenodo
– volume: 60
  start-page: 384
  year: 2017
  end-page: 403
  ident: bib15
  article-title: Development of an IMU-based foot-ground contact detection (FGCD) algorithm
  publication-title: Ergonomics
– volume: 8
  start-page: 135
  year: 1999
  end-page: 160
  ident: bib24
  article-title: Measuring agreement in method comparison studies
  publication-title: Stat. Methods Med. Res.
– start-page: 5067
  year: 2016
  end-page: 5070
  ident: bib18
  article-title: Real-time gait event detection for lower limb amputees using a single wearable sensor
  publication-title: 2016 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
– volume: 13
  start-page: 641
  year: 2016
  end-page: 659
  ident: bib2
  article-title: Wearable inertial sensors for human movement analysis
  publication-title: Expet Rev. Med. Dev.
– volume: 48
  start-page: 1251
  year: 2010
  end-page: 1260
  ident: bib8
  article-title: An adaptive gyroscope-based algorithm for temporal gait analysis
  publication-title: Med. Biol. Eng. Comput.
– year: 2009
  ident: bib1
  article-title: Biomechanics and Motor Control of Human Movement
– volume: 49
  start-page: 332
  year: 2016
  end-page: 337
  ident: bib7
  article-title: Gait recording with inertial sensors – how to determine initial and terminal contact
  publication-title: J. Biomech.
– year: 2007
  ident: bib4
  article-title: Gait Analysis: an Introduction
– volume: 22
  start-page: 3859
  year: 2022
  ident: bib9
  article-title: A deep learning approach for gait event detection from a single shank-worn IMU: validation in healthy and neurological cohorts
  publication-title: Sensors
– volume: 37
  start-page: 226
  year: 2015
  end-page: 232
  ident: bib13
  article-title: Development and validation of an accelerometer-based method for quantifying gait events
  publication-title: Med. Eng. Phys.
– volume: 11
  start-page: 152
  year: 2014
  ident: bib11
  article-title: Estimation of step-by-step spatio-temporal parameters of normal and impaired gait using shank-mounted magneto-inertial sensors: application to elderly, hemiparetic, parkinsonian and choreic gait
  publication-title: J. NeuroEng. Rehabil.
– volume: 28
  start-page: 211
  year: 2020
  end-page: 220
  ident: bib21
  article-title: Gait trajectory and event prediction from state estimation for exoskeletons during gait
  publication-title: IEEE Trans. Neural Syst. Rehabil. Eng.
– volume: 50
  start-page: 2171
  year: 2007
  end-page: 2182
  ident: bib12
  article-title: The influence of boot stiffness on gait kinematics and kinetics during stance phase
  publication-title: Ergonomics
– volume: 37
  start-page: 229
  year: 2013
  end-page: 234
  ident: bib19
  article-title: Quantitative estimation of foot-flat and stance phase of gait using foot-worn inertial sensors
  publication-title: Gait Posture
– volume: 9
  start-page: 113
  year: 2001
  end-page: 125
  ident: bib20
  article-title: A reliable gait phase detection system
  publication-title: IEEE Trans. Nucl. Sci.
– volume: 17
  year: 2017
  ident: bib16
  article-title: Real-time gait event detection based on kinematic data coupled to a biomechanical model
  publication-title: Sensors
– volume: 20
  start-page: 266
  year: 2004
  end-page: 272
  ident: bib14
  article-title: Assessment and validation of a simple automated method for the detection of gait events and intervals
  publication-title: Gait Posture
– volume: 21
  year: 2021
  ident: bib3
  article-title: Wearable sensor-based real-time gait detection: a systematic review
  publication-title: Sensors
– volume: 111
  start-page: 1
  year: 2024
  end-page: 7
  ident: bib10
  article-title: A novel method for accurate division of the gait cycle into seven phases using shank angular velocity
  publication-title: Gait Posture
– volume: 45
  year: 2015
  ident: bib22
  article-title: System of gait analysis based on ground reaction force assessment
  publication-title: Acta Gymnica
– volume: 55
  year: 2017
  ident: bib6
  article-title: The development and concurrent validity of a real-time algorithm for temporal gait analysis using inertial measurement units
  publication-title: J. Biomech.
– volume: 22
  start-page: 3859
  year: 2022
  ident: 10.1016/j.heliyon.2024.e33546_bib9
  article-title: A deep learning approach for gait event detection from a single shank-worn IMU: validation in healthy and neurological cohorts
  publication-title: Sensors
  doi: 10.3390/s22103859
– volume: 20
  start-page: 266
  year: 2004
  ident: 10.1016/j.heliyon.2024.e33546_bib14
  article-title: Assessment and validation of a simple automated method for the detection of gait events and intervals
  publication-title: Gait Posture
  doi: 10.1016/j.gaitpost.2003.10.001
– volume: 28
  start-page: 211
  year: 2020
  ident: 10.1016/j.heliyon.2024.e33546_bib21
  article-title: Gait trajectory and event prediction from state estimation for exoskeletons during gait
  publication-title: IEEE Trans. Neural Syst. Rehabil. Eng.
  doi: 10.1109/TNSRE.2019.2950309
– year: 2007
  ident: 10.1016/j.heliyon.2024.e33546_bib4
– volume: 50
  start-page: 2171
  year: 2007
  ident: 10.1016/j.heliyon.2024.e33546_bib12
  article-title: The influence of boot stiffness on gait kinematics and kinetics during stance phase
  publication-title: Ergonomics
  doi: 10.1080/00140130701582104
– volume: 55
  year: 2017
  ident: 10.1016/j.heliyon.2024.e33546_bib6
  article-title: The development and concurrent validity of a real-time algorithm for temporal gait analysis using inertial measurement units
  publication-title: J. Biomech.
  doi: 10.1016/j.jbiomech.2017.02.016
– volume: 111
  start-page: 1
  year: 2024
  ident: 10.1016/j.heliyon.2024.e33546_bib10
  article-title: A novel method for accurate division of the gait cycle into seven phases using shank angular velocity
  publication-title: Gait Posture
  doi: 10.1016/j.gaitpost.2024.04.006
– volume: 60
  start-page: 384
  year: 2017
  ident: 10.1016/j.heliyon.2024.e33546_bib15
  article-title: Development of an IMU-based foot-ground contact detection (FGCD) algorithm
  publication-title: Ergonomics
  doi: 10.1080/00140139.2016.1174314
– start-page: 5067
  year: 2016
  ident: 10.1016/j.heliyon.2024.e33546_bib18
  article-title: Real-time gait event detection for lower limb amputees using a single wearable sensor
– volume: 13
  start-page: 641
  year: 2016
  ident: 10.1016/j.heliyon.2024.e33546_bib2
  article-title: Wearable inertial sensors for human movement analysis
  publication-title: Expet Rev. Med. Dev.
  doi: 10.1080/17434440.2016.1198694
– volume: 8
  start-page: 135
  year: 1999
  ident: 10.1016/j.heliyon.2024.e33546_bib24
  article-title: Measuring agreement in method comparison studies
  publication-title: Stat. Methods Med. Res.
  doi: 10.1177/096228029900800204
– volume: 92
  year: 2021
  ident: 10.1016/j.heliyon.2024.e33546_bib17
  article-title: Gait phase detection based on inertial measurement unit and force-sensitive resistors embedded in a shoe
  publication-title: Rev. Sci. Instrum.
  doi: 10.1063/5.0056893
– year: 2010
  ident: 10.1016/j.heliyon.2024.e33546_bib5
– volume: 1
  start-page: 30
  year: 1996
  ident: 10.1016/j.heliyon.2024.e33546_bib25
  article-title: Forming inferences about some intraclass correlation coefficients
  publication-title: Psychol. Methods
  doi: 10.1037/1082-989X.1.1.30
– volume: 49
  start-page: 332
  year: 2016
  ident: 10.1016/j.heliyon.2024.e33546_bib7
  article-title: Gait recording with inertial sensors – how to determine initial and terminal contact
  publication-title: J. Biomech.
  doi: 10.1016/j.jbiomech.2015.12.035
– volume: 37
  start-page: 229
  year: 2013
  ident: 10.1016/j.heliyon.2024.e33546_bib19
  article-title: Quantitative estimation of foot-flat and stance phase of gait using foot-worn inertial sensors
  publication-title: Gait Posture
  doi: 10.1016/j.gaitpost.2012.07.012
– volume: 48
  start-page: 1251
  year: 2010
  ident: 10.1016/j.heliyon.2024.e33546_bib8
  article-title: An adaptive gyroscope-based algorithm for temporal gait analysis
  publication-title: Med. Biol. Eng. Comput.
  doi: 10.1007/s11517-010-0692-0
– year: 2009
  ident: 10.1016/j.heliyon.2024.e33546_bib1
– volume: 17
  year: 2017
  ident: 10.1016/j.heliyon.2024.e33546_bib16
  article-title: Real-time gait event detection based on kinematic data coupled to a biomechanical model
  publication-title: Sensors
  doi: 10.3390/s17040671
– volume: 45
  year: 2015
  ident: 10.1016/j.heliyon.2024.e33546_bib22
  article-title: System of gait analysis based on ground reaction force assessment
  publication-title: Acta Gymnica
  doi: 10.5507/ag.2015.022
– volume: 11
  start-page: 152
  year: 2014
  ident: 10.1016/j.heliyon.2024.e33546_bib11
  article-title: Estimation of step-by-step spatio-temporal parameters of normal and impaired gait using shank-mounted magneto-inertial sensors: application to elderly, hemiparetic, parkinsonian and choreic gait
  publication-title: J. NeuroEng. Rehabil.
  doi: 10.1186/1743-0003-11-152
– volume: 37
  start-page: 226
  year: 2015
  ident: 10.1016/j.heliyon.2024.e33546_bib13
  article-title: Development and validation of an accelerometer-based method for quantifying gait events
  publication-title: Med. Eng. Phys.
  doi: 10.1016/j.medengphy.2015.01.001
– volume: 9
  start-page: 113
  year: 2001
  ident: 10.1016/j.heliyon.2024.e33546_bib20
  article-title: A reliable gait phase detection system
  publication-title: IEEE Trans. Nucl. Sci.
– volume: 21
  year: 2021
  ident: 10.1016/j.heliyon.2024.e33546_bib3
  article-title: Wearable sensor-based real-time gait detection: a systematic review
  publication-title: Sensors
  doi: 10.3390/s21082727
– year: 2023
  ident: 10.1016/j.heliyon.2024.e33546_bib23
  article-title: A heel rise event visual detection tool
  publication-title: Zenodo
SSID ssj0001586973
Score 2.2694838
Snippet Accurate identification of gait events is crucial to reliable gait analysis. Heel rise, a key event marking the transition from mid-stance to terminal stance,...
• We assess motion capture, force plate, and IMU data to identify the most precise heel rise detection method. • Subtle rising of the heel before the actual...
Background: Accurate identification of gait events is crucial to reliable gait analysis. Heel rise, a key event marking the transition from mid-stance to...
SourceID doaj
pubmedcentral
proquest
pubmed
crossref
elsevier
SourceType Open Website
Open Access Repository
Aggregation Database
Index Database
Publisher
StartPage e33546
SubjectTerms algorithms
cost effectiveness
Event detection
gait
Gait analysis
Heel-off
Inertial measurement unit (IMU)
Optical motion capture
separation
Shank angular velocity
Title Comparative assessment of heel rise detection for consistent gait phase separation
URI https://dx.doi.org/10.1016/j.heliyon.2024.e33546
https://www.ncbi.nlm.nih.gov/pubmed/39040320
https://www.proquest.com/docview/3083680399
https://www.proquest.com/docview/3153811801
https://pubmed.ncbi.nlm.nih.gov/PMC11260980
https://doaj.org/article/88c3f052a522472c88863513813de98d
Volume 10
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwrV1Lb9wgEEZVKlW9VH13-4io1Ks3YDCGYxo1ihqlh6hRc0M8uxtFdpQ4h_77zhjvZreVmkuvNmCYAb4PGD4T8gkwOXkfAm4v6QoQwlcmZ18JkVlbh5qHFm8jn3xTR2fy63lzvvGrL4wJK_LAxXB7WgfI1tQOiIKE3LBiA4zkADQiJqMjzr6AeRuLqXI_WCvTirsrO3sX80W6XP7qUfO0lvMkRIOkdwOMRs3-LUz6m3P-GTq5gUWHT8mTiUTS_VL5Z-RB6p6TRyfTMfkLcnpwp-lN3Vp7k_aZLlK6pDCwE41pGMOwOgq8lQYMlAWPQ6qfbjnQqwXAG71JpZi-e0nODr98Pziqpp8nVAEoylBFxZxvdRatcwp4geI8ShOAS0dt6ixUDrlmAQyL4g1ZGx50lsJ7qVlgiolXZKfru_SG0CYmH3ydkkR9QSWNcJEHJyOMZuV5mJH5yor2qmhk2FXw2IWdzG7R7LaYfUY-o63XiVHienwAjreT4-19jp8RvfKUndhCYQFQ1PK-739cedbCaMIjEtel_vbGChTr1gxY2z_SIEigch6fkdelN6xbIgxMiqJmULmtfrLV1O033XIxqnrjXS5mNHv7P4zzjjzG9uImNG_ek53h-jZ9APY0-F3ycP_49Mfx7jhgfgM00Rl4
linkProvider Directory of Open Access Journals
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Comparative+assessment+of+heel+rise+detection+for+consistent+gait+phase+separation&rft.jtitle=Heliyon&rft.au=Salminen%2C+Mikko&rft.au=Perttunen%2C+Jarmo&rft.au=Avela%2C+Janne&rft.au=Vehkaoja%2C+Antti&rft.date=2024-07-15&rft.pub=Elsevier+Ltd&rft.issn=2405-8440&rft.eissn=2405-8440&rft.volume=10&rft.issue=13&rft_id=info:doi/10.1016%2Fj.heliyon.2024.e33546&rft.externalDocID=S240584402409577X
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=2405-8440&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=2405-8440&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=2405-8440&client=summon