Novel Technology Allowing Cone Beam Computed Tomography in 6 Seconds: A Patient Study of Comparative Image Quality
The goal of this study was to evaluate the image quality provided by a novel cone beam computed tomography (CBCT) platform (HyperSight, Varian Medical Systems), a platform with enhanced reconstruction algorithms as well as rapid acquisition times. Image quality was compared with both status quo CBCT...
Saved in:
Published in | Practical radiation oncology Vol. 14; no. 3; p. 277 |
---|---|
Main Authors | , , , , , , , , , |
Format | Journal Article |
Language | English |
Published |
United States
01.05.2024
|
Subjects | |
Online Access | Get more information |
ISSN | 1879-8519 |
DOI | 10.1016/j.prro.2023.10.014 |
Cover
Loading…
Abstract | The goal of this study was to evaluate the image quality provided by a novel cone beam computed tomography (CBCT) platform (HyperSight, Varian Medical Systems), a platform with enhanced reconstruction algorithms as well as rapid acquisition times. Image quality was compared with both status quo CBCT for image guidance, and to fan beam CT (FBCT) acquired on a CT simulator (CTsim).
In a clinical study, 30 individuals were recruited for whom either deep inspiration (DIBH) or deep exhalation breath hold (DEBH) was used during imaging and radiation treatment of tumors involving liver, lung, breast, abdomen, chest wall, and pancreatic sites. All subjects were imaged during breath hold with CBCT on a standard image guidance platform (TrueBeam 2.7, Varian Medical Systems) and FBCT CT (CTsim, GE Optima). HyperSight imaging with both breath hold (HSBH) and free breathing (HSFB) was performed in a single session. The 4 image sets thus acquired were registered and compared using metrics quantifying artifact index, image nonuniformity, contrast, contrast-to-noise ratio, and difference of Hounsfield unit (HU) from CTsim.
HSBH provided less severe artifacts compared with both HSFB and TrueBeam. The severity of artifacts in HSBH images was similar to that in CTsim images, with statistically similar artifact index values. CTsim provided the best image uniformity; however, HSBH provided improved uniformity compared with both HSFB and TrueBeam. CTsim demonstrated elevated contrast compared with HyperSight imaging, but both HSBH and HSFB imaging showed superior contrast-to-noise ratio characteristics compared with TrueBeam. The median HU difference of HSBH from CTsim was within 1 HU for muscle/fat tissue, 12 HU for bone, and 14 HU for lung.
The HyperSight system provides 6-second CBCT acquisition with image artifacts that are significantly reduced compared with TrueBeam and comparable to those in CTsim FBCT imaging. HyperSight breath hold imaging was of higher quality compared with free breathing imaging on the same system. The median HU value in HyperSight breath hold imaging is within 15 HU of that in CTsim imaging for muscle, fat, bone, and lung tissue types, indicating the utility of image data for direct dose calculation in adaptive workflows. |
---|---|
AbstractList | The goal of this study was to evaluate the image quality provided by a novel cone beam computed tomography (CBCT) platform (HyperSight, Varian Medical Systems), a platform with enhanced reconstruction algorithms as well as rapid acquisition times. Image quality was compared with both status quo CBCT for image guidance, and to fan beam CT (FBCT) acquired on a CT simulator (CTsim).
In a clinical study, 30 individuals were recruited for whom either deep inspiration (DIBH) or deep exhalation breath hold (DEBH) was used during imaging and radiation treatment of tumors involving liver, lung, breast, abdomen, chest wall, and pancreatic sites. All subjects were imaged during breath hold with CBCT on a standard image guidance platform (TrueBeam 2.7, Varian Medical Systems) and FBCT CT (CTsim, GE Optima). HyperSight imaging with both breath hold (HSBH) and free breathing (HSFB) was performed in a single session. The 4 image sets thus acquired were registered and compared using metrics quantifying artifact index, image nonuniformity, contrast, contrast-to-noise ratio, and difference of Hounsfield unit (HU) from CTsim.
HSBH provided less severe artifacts compared with both HSFB and TrueBeam. The severity of artifacts in HSBH images was similar to that in CTsim images, with statistically similar artifact index values. CTsim provided the best image uniformity; however, HSBH provided improved uniformity compared with both HSFB and TrueBeam. CTsim demonstrated elevated contrast compared with HyperSight imaging, but both HSBH and HSFB imaging showed superior contrast-to-noise ratio characteristics compared with TrueBeam. The median HU difference of HSBH from CTsim was within 1 HU for muscle/fat tissue, 12 HU for bone, and 14 HU for lung.
The HyperSight system provides 6-second CBCT acquisition with image artifacts that are significantly reduced compared with TrueBeam and comparable to those in CTsim FBCT imaging. HyperSight breath hold imaging was of higher quality compared with free breathing imaging on the same system. The median HU value in HyperSight breath hold imaging is within 15 HU of that in CTsim imaging for muscle, fat, bone, and lung tissue types, indicating the utility of image data for direct dose calculation in adaptive workflows. |
Author | Dahn, Hannah Patil, Nikhilesh MacDonald, Robert Lee Cwajna, Slawa Robar, James L McAloney, David Cherpak, Amanda McMaster, Natasha Yashayaeva, Abigail Zhan, Kenny |
Author_xml | – sequence: 1 givenname: James L surname: Robar fullname: Robar, James L email: james.robar@nshealth.ca organization: Department of Radiation Oncology, QE2 Cancer Centre, Nova Scotia Health, Halifax, Canada; Departments of Radiation Oncology; Physics and Atmospheric Science, Dalhousie University, Halifax, Canada. Electronic address: james.robar@nshealth.ca – sequence: 2 givenname: Amanda surname: Cherpak fullname: Cherpak, Amanda organization: Department of Radiation Oncology, QE2 Cancer Centre, Nova Scotia Health, Halifax, Canada; Departments of Radiation Oncology; Physics and Atmospheric Science, Dalhousie University, Halifax, Canada – sequence: 3 givenname: Robert Lee surname: MacDonald fullname: MacDonald, Robert Lee organization: Department of Radiation Oncology, QE2 Cancer Centre, Nova Scotia Health, Halifax, Canada; Departments of Radiation Oncology; Physics and Atmospheric Science, Dalhousie University, Halifax, Canada – sequence: 4 givenname: Abigail surname: Yashayaeva fullname: Yashayaeva, Abigail organization: Physics and Atmospheric Science, Dalhousie University, Halifax, Canada – sequence: 5 givenname: David surname: McAloney fullname: McAloney, David organization: Department of Radiation Oncology, QE2 Cancer Centre, Nova Scotia Health, Halifax, Canada – sequence: 6 givenname: Natasha surname: McMaster fullname: McMaster, Natasha organization: Department of Radiation Oncology, QE2 Cancer Centre, Nova Scotia Health, Halifax, Canada – sequence: 7 givenname: Kenny surname: Zhan fullname: Zhan, Kenny organization: Department of Radiation Oncology, QE2 Cancer Centre, Nova Scotia Health, Halifax, Canada – sequence: 8 givenname: Slawa surname: Cwajna fullname: Cwajna, Slawa organization: Department of Radiation Oncology, QE2 Cancer Centre, Nova Scotia Health, Halifax, Canada; Departments of Radiation Oncology – sequence: 9 givenname: Nikhilesh surname: Patil fullname: Patil, Nikhilesh organization: Department of Radiation Oncology, QE2 Cancer Centre, Nova Scotia Health, Halifax, Canada; Departments of Radiation Oncology – sequence: 10 givenname: Hannah surname: Dahn fullname: Dahn, Hannah organization: Department of Radiation Oncology, QE2 Cancer Centre, Nova Scotia Health, Halifax, Canada; Departments of Radiation Oncology |
BackLink | https://www.ncbi.nlm.nih.gov/pubmed/37939844$$D View this record in MEDLINE/PubMed |
BookMark | eNo1j9tKw0AURQdRtFZ_wAc5P5A4l2Qm41st3qB4ofW5zExO0kiSCdOkkr83eHnamwV7wT4nx61vkZArRmNGmbz5jLsQfMwpFxOIKUuOyIxlSkdZyvQpORNKC50lyYyEF3_AGjbodq2vfTnCoq79V9WWsJykcIemmVrTDT3msPGNL4PpdiNULUhYo_Ntvr-FBbyZvsK2h3U_5CP44mdkwkQPCM-NKRHeB1NX_XhBTgpT7_HyL-fk4-F-s3yKVq-Pz8vFKnIplX3E0RmFRjnUQlqUVCRaOyVtqilX1sjUFVQ5JtKCCkwVJs5xaqy2mVOWF3xOrn-93WAbzLddqBoTxu3_ef4NqllbZQ |
CitedBy_id | crossref_primary_10_37549_ARO_D_24_00021 crossref_primary_10_1002_mp_17721 crossref_primary_10_1088_1361_6560_ad4a1c crossref_primary_10_3390_cancers16223770 crossref_primary_10_1002_mp_17549 crossref_primary_10_1016_j_phro_2024_100687 crossref_primary_10_1016_j_adro_2024_101692 crossref_primary_10_1016_j_phro_2024_100640 crossref_primary_10_1016_j_ijrobp_2024_03_039 crossref_primary_10_1002_acm2_70023 crossref_primary_10_1002_acm2_70060 crossref_primary_10_1016_j_neuroimage_2024_120922 crossref_primary_10_1088_2057_1976_ad3bb9 crossref_primary_10_7759_cureus_68386 crossref_primary_10_1016_j_ejmp_2025_104946 crossref_primary_10_7759_cureus_66943 crossref_primary_10_1002_acm2_14337 crossref_primary_10_1016_j_yao_2025_02_003 crossref_primary_10_1016_j_phro_2024_100611 crossref_primary_10_7759_cureus_75284 crossref_primary_10_1002_acm2_14438 crossref_primary_10_1016_j_adro_2024_101681 crossref_primary_10_1016_j_clon_2024_05_018 crossref_primary_10_1016_j_radonc_2024_110178 crossref_primary_10_1002_acm2_14464 crossref_primary_10_1002_acm2_70038 crossref_primary_10_7759_cureus_66876 crossref_primary_10_1016_j_semradonc_2024_07_005 crossref_primary_10_1088_1361_6560_ad311b crossref_primary_10_37549_ARO_D_24_00037 crossref_primary_10_7759_cureus_68990 |
ContentType | Journal Article |
Copyright | Copyright © 2023 The Author(s). Published by Elsevier Inc. All rights reserved. |
Copyright_xml | – notice: Copyright © 2023 The Author(s). Published by Elsevier Inc. All rights reserved. |
DBID | CGR CUY CVF ECM EIF NPM |
DOI | 10.1016/j.prro.2023.10.014 |
DatabaseName | Medline MEDLINE MEDLINE (Ovid) MEDLINE MEDLINE PubMed |
DatabaseTitle | MEDLINE Medline Complete MEDLINE with Full Text PubMed MEDLINE (Ovid) |
DatabaseTitleList | MEDLINE |
Database_xml | – sequence: 1 dbid: NPM name: PubMed url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed sourceTypes: Index Database – sequence: 2 dbid: EIF name: MEDLINE url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search sourceTypes: Index Database |
DeliveryMethod | no_fulltext_linktorsrc |
EISSN | 1879-8519 |
ExternalDocumentID | 37939844 |
Genre | Journal Article Comparative Study |
GroupedDBID | CGR CUY CVF ECM EIF NPM |
ID | FETCH-LOGICAL-c506t-2eca7ea7ce936be603499c76b59027ba65cf07c135f03e57e4cc20ab9b8c7b2f2 |
IngestDate | Thu Jan 02 22:45:08 EST 2025 |
IsDoiOpenAccess | false |
IsOpenAccess | true |
IsPeerReviewed | true |
IsScholarly | true |
Issue | 3 |
Language | English |
License | Copyright © 2023 The Author(s). Published by Elsevier Inc. All rights reserved. |
LinkModel | OpenURL |
MergedId | FETCHMERGED-LOGICAL-c506t-2eca7ea7ce936be603499c76b59027ba65cf07c135f03e57e4cc20ab9b8c7b2f2 |
OpenAccessLink | https://dx.doi.org/10.1016/j.prro.2023.10.014 |
PMID | 37939844 |
ParticipantIDs | pubmed_primary_37939844 |
PublicationCentury | 2000 |
PublicationDate | 2024-05-01 |
PublicationDateYYYYMMDD | 2024-05-01 |
PublicationDate_xml | – month: 05 year: 2024 text: 2024-05-01 day: 01 |
PublicationDecade | 2020 |
PublicationPlace | United States |
PublicationPlace_xml | – name: United States |
PublicationTitle | Practical radiation oncology |
PublicationTitleAlternate | Pract Radiat Oncol |
PublicationYear | 2024 |
Score | 2.4915156 |
Snippet | The goal of this study was to evaluate the image quality provided by a novel cone beam computed tomography (CBCT) platform (HyperSight, Varian Medical... |
SourceID | pubmed |
SourceType | Index Database |
StartPage | 277 |
SubjectTerms | Adult Algorithms Breath Holding Cone-Beam Computed Tomography - methods Female Humans Image Processing, Computer-Assisted - methods Male Middle Aged Neoplasms - diagnostic imaging Neoplasms - radiotherapy |
Title | Novel Technology Allowing Cone Beam Computed Tomography in 6 Seconds: A Patient Study of Comparative Image Quality |
URI | https://www.ncbi.nlm.nih.gov/pubmed/37939844 |
Volume | 14 |
hasFullText | |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1db9MwFLU6kNBeEIjvL_mBtypVFjt2zFuZQAOxaUKbNJ6ma-8aNjVp1ZUh-E38SK7tpE0LSIOXKIqVNMo9ub0-OfeYsZeVBistYia1MpmEnSIDrILWFTAvK6D3L6p8D9TesXx_Up4MBj97qqWvCztyP_7YV_I_UaVjFNfQJfsPkV1elA7QPsWXthRh2l4rxgfTK5z02PHheDKZfktf8ql4fI1QD9tlG4Jgpm7tqQPHoQLTPm3OLlNr-mGyV42ywiTR6LmCv6uDsCe5bax9BU5mRyHK82BxkIrPxq0x9R8pYcyXetzhkmveJbDMIObicQ09YmAfeoR1En4PP-ASf5_g8gt8B7xKhLA9_9ypRFruopArpeAIU76ttMmo6DNrCVn2gCf62TWt-PJb1k8ExAX958xDP2chRkGwly7Tg8GsjjgQlJJMJa8xuuHE3Q1tsS2ak4RFVg_32z6sJBnc_P1tdqs7Z2PWEquXozvsdjvt4OOEobtsgM09No_44Sv88A4_POCHB_zwDj98hR9-3nDFW_y84mPeoodH9PCp5z308Ige3qLnPjt---Zody9r1-DIXJmrRVagA42gHRqhLKpgZ2ScVjbY_mgLqnQ-125HlD4XWGqUzhU5WGMrp23hiwfsRkO3_IhxVMZV3oDSZ14K4YGShzUF-BJQ-FI-Zg_TIzqdJaOV0-7hPfnryFO2vcLVM3bT05uNz6lMXNgXMT6_AN4UbNI |
linkProvider | National Library of Medicine |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Novel+Technology+Allowing+Cone+Beam+Computed+Tomography+in+6+Seconds%3A+A+Patient+Study+of+Comparative+Image+Quality&rft.jtitle=Practical+radiation+oncology&rft.au=Robar%2C+James+L&rft.au=Cherpak%2C+Amanda&rft.au=MacDonald%2C+Robert+Lee&rft.au=Yashayaeva%2C+Abigail&rft.date=2024-05-01&rft.eissn=1879-8519&rft.volume=14&rft.issue=3&rft.spage=277&rft_id=info:doi/10.1016%2Fj.prro.2023.10.014&rft_id=info%3Apmid%2F37939844&rft_id=info%3Apmid%2F37939844&rft.externalDocID=37939844 |