Evaluation of dark circles of the lower eyelid: comparison between reflectance meters and image processing and involvement of dermal thickness in appearance

Background/aims: Dark circles of the lower eyelid (DCLE) represent a well‐known beauty problem. The pathogenesis of DCLE is obscure, although stasis and hyperpigmentation of the eyelids have been considered to be involved. One reason for the small number of studies on DCLE may be the difficulty in m...

Full description

Saved in:
Bibliographic Details
Published inSkin Research and Technology Vol. 14; no. 2; pp. 135 - 141
Main Authors Ohshima, Hiroshi, Takiwaki, Hirotsugu
Format Journal Article
LanguageEnglish
Published Oxford, UK Blackwell Publishing Ltd 01.05.2008
Wiley
Subjects
Online AccessGet full text
ISSN0909-752X
1600-0846
1600-0846
DOI10.1111/j.1600-0846.2007.00277.x

Cover

More Information
Summary:Background/aims: Dark circles of the lower eyelid (DCLE) represent a well‐known beauty problem. The pathogenesis of DCLE is obscure, although stasis and hyperpigmentation of the eyelids have been considered to be involved. One reason for the small number of studies on DCLE may be the difficulty in measuring such soft and curved skin as the eyelids using bulky reflectance meters. The purpose of this study was to quantitatively analyze DCLE using various bioengineering methods. Methods: The lower eyelid and cheek areas of 14 subjects with DCLE and 28 without DCLE were examined using two kinds of reflectance meters and image analysis to measure erythema index (EI), melanin index (MI), and oxygenation index (OX). Ultrasound echo images were also recorded to evaluate the thickness and echo density of the dermis. An in vitro model using collagen gel and hemoglobin solution was also examined as a phantom of eyelid skin. Results: When contact‐type reflectance meters were used, no significant differences in EI, MI, and OX were found between groups with and without DCLE. However, mean values of both MI and EI at eyelids were significantly higher in subjects with DCLE on image analysis, paralleling the results of inspection. Mean dermal thickness was significantly smaller in subjects with DCLE. Conclusion: Evaluation of EI and MI by image processing methods seems suitable for quantitative evaluation of DCLE, since inadequate contact of the measuring head with the skin is avoided. Whether stasis or hyperpigmentation is more responsible for DCLE remains uncertain. Dermal thickness of eyelid skin may be involved in the appearance of DCLE.
Bibliography:ark:/67375/WNG-MLL3576J-0
ArticleID:SRT277
istex:FDC28D0CA043D63BD33B0A32E07BD4D154C6C8FE
ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Feature-1
content type line 23
ObjectType-Undefined-3
ISSN:0909-752X
1600-0846
1600-0846
DOI:10.1111/j.1600-0846.2007.00277.x