First Human Use of a New Robotic-Assisted Fiber Optic Sensing Navigation System for Small Peripheral Pulmonary Nodules
Background: We tested a new, investigational robotic-assisted bronchoscope system with a remotely controlled catheter to access small peripheral bronchi with real-time driving under live visualization and distal tip articulation of the catheter. The unique catheter remains stationary once located at...
Saved in:
Published in | Respiration Vol. 98; no. 2; pp. 142 - 150 |
---|---|
Main Authors | , , , , , , , , |
Format | Journal Article |
Language | English |
Published |
Basel, Switzerland
S. Karger AG
01.08.2019
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Abstract | Background: We tested a new, investigational robotic-assisted bronchoscope system with a remotely controlled catheter to access small peripheral bronchi with real-time driving under live visualization and distal tip articulation of the catheter. The unique catheter remains stationary once located at the biopsy position. Objectives: The primary objectives of this study were to evaluate the safety and feasibility of a new shape-sensing robotic bronchoscope system to bronchoscopically approach and facilitate the sampling of small peripheral pulmonary nodules of 1–3 cm. Secondary objectives included evaluating procedural characteristics and early performance trends associated with the use of the new robotic bronchoscope system. Methods: Subjects were enrolled according to study eligibility criteria at a single center. Navigation pathways were semi-automatically created using pre-procedure CT scans. Simultaneous (real-time) viewing of actual and virtual bronchi was used real time during navigation to the displayed target. An endobronchial ultrasound mini-probe was used to confirm lesion location. Flexible 19- to 23-G needles specifically designed to accommodate tight bend radii in transbronchial needle aspiration were used along with conventional biopsy tools. Enrolled subjects completed follow-up visits up to 6 months after the procedure. Results: The study included 29 subjects with a mean lesion size of 12.2 ± 4.2, 12.3 ± 3.3, and 11.7 ± 4.1 mm in the axial, coronal, and sagittal planes, respectively. The CT bronchus sign was absent in 41.4% of cases. In 96.6% of cases, the target was reached, and samples were obtained. No device-related adverse events and no instances of pneumothorax or excessive bleeding were observed during the procedure. Early performance trends demonstrated an overall diagnostic yield of 79.3% and a diagnostic yield for malignancy of 88%. Conclusion: This new robotic-assisted bronchoscope system safely navigated to very small peripheral airways under continuous visualization, and through maintenance of a static position, it provides a unique sampling capability for the biopsy of small solitary pulmonary nodules. |
---|---|
AbstractList | Background: We tested a new, investigational robotic-assisted bronchoscope system with a remotely controlled catheter to access small peripheral bronchi with real-time driving under live visualization and distal tip articulation of the catheter. The unique catheter remains stationary once located at the biopsy position. Objectives: The primary objectives of this study were to evaluate the safety and feasibility of a new shape-sensing robotic bronchoscope system to bronchoscopically approach and facilitate the sampling of small peripheral pulmonary nodules of 1-3 cm. Secondary objectives included evaluating procedural characteristics and early performance trends associated with the use of the new robotic bronchoscope system. Methods: Subjects were enrolled according to study eligibility criteria at a single center. Navigation pathways were semi-automatically created using pre-procedure CT scans. Simultaneous (real-time) viewing of actual and virtual bronchi was used real time during navigation to the displayed target. An endobronchial ultrasound mini-probe was used to confirm lesion location. Flexible 19- to 23-G needles specifically designed to accommodate tight bend radii in transbronchial needle aspiration were used along with conventional biopsy tools. Enrolled subjects completed follow-up visits up to 6 months after the procedure. Results: The study included 29 subjects with a mean lesion size of 12.2 ± 4.2, 12.3 ± 3.3, and 11.7 ± 4.1 mm in the axial, coronal, and sagittal planes, respectively. The CT bronchus sign was absent in 41.4% of cases. In 96.6% of cases, the target was reached, and samples were obtained. No device-related adverse events and no instances of pneumothorax or excessive bleeding were observed during the procedure. Early performance trends demonstrated an overall diagnostic yield of 79.3% and a diagnostic yield for malignancy of 88%. Conclusion: This new robotic-assisted bronchoscope system safely navigated to very small peripheral airways under continuous visualization, and through maintenance of a static position, it provides a unique sampling capability for the biopsy of small solitary pulmonary nodules. Keywords: Lung biopsy, Solitary pulmonary nodule, Robotic bronchoscopy, Lung cancer Background: We tested a new, investigational robotic-assisted bronchoscope system with a remotely controlled catheter to access small peripheral bronchi with real-time driving under live visualization and distal tip articulation of the catheter. The unique catheter remains stationary once located at the biopsy position. Objectives: The primary objectives of this study were to evaluate the safety and feasibility of a new shape-sensing robotic bronchoscope system to bronchoscopically approach and facilitate the sampling of small peripheral pulmonary nodules of 1–3 cm. Secondary objectives included evaluating procedural characteristics and early performance trends associated with the use of the new robotic bronchoscope system. Methods: Subjects were enrolled according to study eligibility criteria at a single center. Navigation pathways were semi-automatically created using pre-procedure CT scans. Simultaneous (real-time) viewing of actual and virtual bronchi was used real time during navigation to the displayed target. An endobronchial ultrasound mini-probe was used to confirm lesion location. Flexible 19- to 23-G needles specifically designed to accommodate tight bend radii in transbronchial needle aspiration were used along with conventional biopsy tools. Enrolled subjects completed follow-up visits up to 6 months after the procedure. Results: The study included 29 subjects with a mean lesion size of 12.2 ± 4.2, 12.3 ± 3.3, and 11.7 ± 4.1 mm in the axial, coronal, and sagittal planes, respectively. The CT bronchus sign was absent in 41.4% of cases. In 96.6% of cases, the target was reached, and samples were obtained. No device-related adverse events and no instances of pneumothorax or excessive bleeding were observed during the procedure. Early performance trends demonstrated an overall diagnostic yield of 79.3% and a diagnostic yield for malignancy of 88%. Conclusion: This new robotic-assisted bronchoscope system safely navigated to very small peripheral airways under continuous visualization, and through maintenance of a static position, it provides a unique sampling capability for the biopsy of small solitary pulmonary nodules. We tested a new, investigational robotic-assisted bronchoscope system with a remotely controlled catheter to access small peripheral bronchi with real-time driving under live visualization and distal tip articulation of the catheter. The unique catheter remains stationary once located at the biopsy position. The primary objectives of this study were to evaluate the safety and feasibility of a new shape-sensing robotic bronchoscope system to bronchoscopically approach and facilitate the sampling of small peripheral pulmonary nodules of 1-3 cm. Secondary objectives included evaluating procedural characteristics and early performance trends associated with the use of the new robotic bronchoscope system. Subjects were enrolled according to study eligibility criteria at a single center. Navigation pathways were semi-automatically created using pre-procedure CT scans. Simultaneous (real-time) viewing of actual and virtual bronchi was used real time during navigation to the displayed target. An endobronchial ultrasound mini-probe was used to confirm lesion location. Flexible 19- to 23-G needles specifically designed to accommodate tight bend radii in transbronchial needle aspiration were used along with conventional biopsy tools. Enrolled subjects completed follow-up visits up to 6 months after the procedure. The study included 29 subjects with a mean lesion size of 12.2 ± 4.2, 12.3 ± 3.3, and 11.7 ± 4.1 mm in the axial, coronal, and sagittal planes, respectively. The CT bronchus sign was absent in 41.4% of cases. In 96.6% of cases, the target was reached, and samples were obtained. No device-related adverse events and no instances of pneumothorax or excessive bleeding were observed during the procedure. Early performance trends demonstrated an overall diagnostic yield of 79.3% and a diagnostic yield for malignancy of 88%. This new robotic-assisted bronchoscope system safely navigated to very small peripheral airways under continuous visualization, and through maintenance of a static position, it provides a unique sampling capability for the biopsy of small solitary pulmonary nodules. We tested a new, investigational robotic-assisted bronchoscope system with a remotely controlled catheter to access small peripheral bronchi with real-time driving under live visualization and distal tip articulation of the catheter. The unique catheter remains stationary once located at the biopsy position.BACKGROUNDWe tested a new, investigational robotic-assisted bronchoscope system with a remotely controlled catheter to access small peripheral bronchi with real-time driving under live visualization and distal tip articulation of the catheter. The unique catheter remains stationary once located at the biopsy position.The primary objectives of this study were to evaluate the safety and feasibility of a new shape-sensing robotic bronchoscope system to bronchoscopically approach and facilitate the sampling of small peripheral pulmonary nodules of 1-3 cm. Secondary objectives included evaluating procedural characteristics and early performance trends associated with the use of the new robotic bronchoscope system.OBJECTIVESThe primary objectives of this study were to evaluate the safety and feasibility of a new shape-sensing robotic bronchoscope system to bronchoscopically approach and facilitate the sampling of small peripheral pulmonary nodules of 1-3 cm. Secondary objectives included evaluating procedural characteristics and early performance trends associated with the use of the new robotic bronchoscope system.Subjects were enrolled according to study eligibility criteria at a single center. Navigation pathways were semi-automatically created using pre-procedure CT scans. Simultaneous (real-time) viewing of actual and virtual bronchi was used real time during navigation to the displayed target. An endobronchial ultrasound mini-probe was used to confirm lesion location. Flexible 19- to 23-G needles specifically designed to accommodate tight bend radii in transbronchial needle aspiration were used along with conventional biopsy tools. Enrolled subjects completed follow-up visits up to 6 months after the procedure.METHODSSubjects were enrolled according to study eligibility criteria at a single center. Navigation pathways were semi-automatically created using pre-procedure CT scans. Simultaneous (real-time) viewing of actual and virtual bronchi was used real time during navigation to the displayed target. An endobronchial ultrasound mini-probe was used to confirm lesion location. Flexible 19- to 23-G needles specifically designed to accommodate tight bend radii in transbronchial needle aspiration were used along with conventional biopsy tools. Enrolled subjects completed follow-up visits up to 6 months after the procedure.The study included 29 subjects with a mean lesion size of 12.2 ± 4.2, 12.3 ± 3.3, and 11.7 ± 4.1 mm in the axial, coronal, and sagittal planes, respectively. The CT bronchus sign was absent in 41.4% of cases. In 96.6% of cases, the target was reached, and samples were obtained. No device-related adverse events and no instances of pneumothorax or excessive bleeding were observed during the procedure. Early performance trends demonstrated an overall diagnostic yield of 79.3% and a diagnostic yield for malignancy of 88%.RESULTSThe study included 29 subjects with a mean lesion size of 12.2 ± 4.2, 12.3 ± 3.3, and 11.7 ± 4.1 mm in the axial, coronal, and sagittal planes, respectively. The CT bronchus sign was absent in 41.4% of cases. In 96.6% of cases, the target was reached, and samples were obtained. No device-related adverse events and no instances of pneumothorax or excessive bleeding were observed during the procedure. Early performance trends demonstrated an overall diagnostic yield of 79.3% and a diagnostic yield for malignancy of 88%.This new robotic-assisted bronchoscope system safely navigated to very small peripheral airways under continuous visualization, and through maintenance of a static position, it provides a unique sampling capability for the biopsy of small solitary pulmonary nodules.CONCLUSIONThis new robotic-assisted bronchoscope system safely navigated to very small peripheral airways under continuous visualization, and through maintenance of a static position, it provides a unique sampling capability for the biopsy of small solitary pulmonary nodules. |
Audience | Academic |
Author | Bashirzadeh, Farzad Son, Jung Hwa Windsor, Morgan N. Fielding, David I.K. Tan, Lionel Steinke, Karin Sung, Arthur Wai Todman, Maryann Chin, Adrian |
Author_xml | – sequence: 1 givenname: David I.K. surname: Fielding fullname: Fielding, David I.K. email: David.Fielding@health.qld.gov.au – sequence: 2 givenname: Farzad surname: Bashirzadeh fullname: Bashirzadeh, Farzad – sequence: 3 givenname: Jung Hwa surname: Son fullname: Son, Jung Hwa – sequence: 4 givenname: Maryann surname: Todman fullname: Todman, Maryann – sequence: 5 givenname: Adrian surname: Chin fullname: Chin, Adrian – sequence: 6 givenname: Lionel surname: Tan fullname: Tan, Lionel – sequence: 7 givenname: Karin surname: Steinke fullname: Steinke, Karin – sequence: 8 givenname: Morgan N. surname: Windsor fullname: Windsor, Morgan N. – sequence: 9 givenname: Arthur Wai surname: Sung fullname: Sung, Arthur Wai |
BackLink | https://www.ncbi.nlm.nih.gov/pubmed/31352444$$D View this record in MEDLINE/PubMed |
BookMark | eNptkk1rGzEQhkVJaRy3h95LERRKe9hEn_txNCFOCsEpcXMW0u6srVa7cqXdlPz7yLUTmmJ0GDE87zDzzpygo973gNB7Sk4pldUZIURUZSXpKzShgvGMcJkfoQkhTGZFxekxOonxJyFUliV7g4455ZIJISbofm5DHPDV2Oke30XAvsUaL-APvvXGD7bOZjHaOECD59ZAwDeblMRL6KPtV3ih7-1KD9b3ePmQqA63PuBlp53D3yHYzRqCTt_Rdb7X4QEvfDM6iG_R61a7CO_2cYru5hc_zq-y65vLb-ez66xOAw0ZhYYKbSRtCiYb3RaEGVM0pBCkliUxjJs850xzwQqal00uKtHKojamBBAV8Cn6squ7Cf73CHFQnY01OKd78GNUjCU95yQZMkWfduhKO1C2b_0QdL3F1WzLSCl4lajTA1R6DXS2Tmtpbcq_EHz-R7AG7YZ19G7cehZfgh_3rY6mg0Ztgu2SY-ppVwk42wF18DEGaFVth7_epxasU5So7TWo52tIiq__KZ6KHmL34__SYQXhmby9WO4ItWnaRH04SO2LPALktMWc |
CitedBy_id | crossref_primary_10_2147_POR_S395806 crossref_primary_10_1038_s41598_021_03219_6 crossref_primary_10_7759_cureus_62532 crossref_primary_10_3389_fonc_2025_1555151 crossref_primary_10_1016_j_athoracsur_2021_12_041 crossref_primary_10_1136_thoraxjnl_2021_217745 crossref_primary_10_1186_s12890_021_01584_6 crossref_primary_10_3390_life13020354 crossref_primary_10_1097_LBR_0000000000000957 crossref_primary_10_1016_j_chest_2022_10_019 crossref_primary_10_1109_TBME_2021_3077356 crossref_primary_10_1080_17476348_2023_2192929 crossref_primary_10_1164_rccm_201907_1292SO crossref_primary_10_1186_s12890_021_01693_2 crossref_primary_10_1097_MCP_0000000000001021 crossref_primary_10_1111_resp_13966 crossref_primary_10_1111_resp_14402 crossref_primary_10_1136_thoraxjnl_2021_216885 crossref_primary_10_1016_j_jtho_2021_12_008 crossref_primary_10_1111_resp_14368 crossref_primary_10_1513_AnnalsATS_202301_075OC crossref_primary_10_3389_pore_2024_1611774 crossref_primary_10_1111_resp_13791 crossref_primary_10_12677_acm_2024_1441308 crossref_primary_10_3389_fsurg_2020_596925 crossref_primary_10_1097_LBR_0000000000000687 crossref_primary_10_3390_diagnostics11081479 crossref_primary_10_1016_j_athoracsur_2022_11_022 crossref_primary_10_1016_j_bpa_2024_05_002 crossref_primary_10_1186_s12890_023_02465_w crossref_primary_10_1159_000533314 crossref_primary_10_1109_JPROC_2022_3170109 crossref_primary_10_1016_j_mayocpiqo_2022_02_004 crossref_primary_10_1183_16000617_0184_2019 crossref_primary_10_1080_08998280_2023_2193134 crossref_primary_10_1177_20406223221146723 crossref_primary_10_1097_MJT_0000000000001344 crossref_primary_10_1097_LBR_0000000000000697 crossref_primary_10_1109_LRA_2024_3397529 crossref_primary_10_1016_j_rmcr_2023_101855 crossref_primary_10_1111_resp_13903 crossref_primary_10_1111_resp_14789 crossref_primary_10_1111_resp_14385 crossref_primary_10_1080_17476348_2024_2387089 crossref_primary_10_3390_cancers15041068 crossref_primary_10_3390_diagnostics11122304 crossref_primary_10_1097_LBR_0000000000000981 crossref_primary_10_1111_resp_14549 crossref_primary_10_1055_a_1186_7333 crossref_primary_10_1016_j_thorsurg_2023_04_009 crossref_primary_10_1016_j_suc_2022_01_004 crossref_primary_10_3390_diagnostics13142393 crossref_primary_10_1183_16000617_0035_2020 crossref_primary_10_1111_resp_14296 crossref_primary_10_23736_S2784_8477_24_02125_9 crossref_primary_10_1016_j_lungcan_2023_107196 crossref_primary_10_3390_cancers16061179 crossref_primary_10_1159_000504181 crossref_primary_10_1016_j_chpulm_2024_100131 crossref_primary_10_1109_TMRB_2023_3291024 crossref_primary_10_1016_j_compbiomed_2024_108199 crossref_primary_10_1007_s13665_020_00265_9 crossref_primary_10_3390_jcm10235678 crossref_primary_10_3390_diagnostics12010174 crossref_primary_10_1177_15569845231153639 crossref_primary_10_3389_fmed_2022_989184 crossref_primary_10_1007_s11548_024_03243_7 crossref_primary_10_1159_000516393 crossref_primary_10_1007_s15015_021_3747_1 crossref_primary_10_1097_LBR_0000000000000923 crossref_primary_10_34197_ats_scholar_2020_0033OC crossref_primary_10_1055_s_0042_1747930 crossref_primary_10_1111_anae_14986 crossref_primary_10_1016_j_chest_2021_08_074 crossref_primary_10_58585_respend_2024_0039 crossref_primary_10_1111_1759_7714_15222 crossref_primary_10_18410_jebmh_2016_1139 crossref_primary_10_1097_LBR_0000000000000650 crossref_primary_10_1016_j_rmed_2023_107277 crossref_primary_10_1007_s00408_022_00590_7 crossref_primary_10_1513_AnnalsATS_202302_182OC crossref_primary_10_3390_diagnostics14040399 crossref_primary_10_1016_j_medengphy_2024_104116 crossref_primary_10_1007_s13665_023_00330_z crossref_primary_10_1007_s10405_021_00413_1 crossref_primary_10_1007_s00408_021_00421_1 crossref_primary_10_1016_j_jimed_2021_09_002 crossref_primary_10_1093_nsr_nwae186 crossref_primary_10_1016_j_rmed_2022_106941 crossref_primary_10_1177_1556984521997421 crossref_primary_10_1016_j_lungcan_2023_01_012 crossref_primary_10_1097_MCP_0000000000000782 crossref_primary_10_1016_j_chest_2019_10_016 crossref_primary_10_52581_1814_1471_81_16 crossref_primary_10_1053_j_semtcvs_2020_08_008 crossref_primary_10_1097_MOG_0000000000000670 crossref_primary_10_1088_1361_6560_abca07 crossref_primary_10_1016_j_pccm_2023_01_001 crossref_primary_10_1146_annurev_med_050922_060929 crossref_primary_10_1016_j_athoracsur_2021_06_086 crossref_primary_10_1016_j_chest_2021_07_2169 crossref_primary_10_1111_1759_7714_15229 crossref_primary_10_3390_diagnostics11111984 crossref_primary_10_1097_LBR_0000000000000942 |
Cites_doi | 10.1097/LBR.0000000000000027 10.4103/atm.ATM_428_16 10.1159/000431383 10.1016/j.rcl.2017.06.003 10.1164/rccm.201502-0205OC 10.1159/000232394 10.1186/1465-9921-14-50 10.1186/s12880-015-0060-5 10.1378/chest.11-1764 10.1093/jjco/hyw180 10.1378/chest.126.3.959 10.1136/thx.2010.145490 10.1159/000355710 10.1586/17476348.2014.948855 10.1164/rccm.200612-1866OC 10.1164/rccm.201507-1332OC 10.1016/j.resinv.2015.11.008 10.1056/NEJMoa1102873 10.1517/17530059.2.5.461 10.1097/LBR.0000000000000499 10.1097/LBR.0b013e3182198f24 |
ContentType | Journal Article |
Copyright | 2019 S. Karger AG, Basel 2019 S. Karger AG, Basel. COPYRIGHT 2019 S. Karger AG |
Copyright_xml | – notice: 2019 S. Karger AG, Basel – notice: 2019 S. Karger AG, Basel. – notice: COPYRIGHT 2019 S. Karger AG |
DBID | AAYXX CITATION NPM 7X8 |
DOI | 10.1159/000498951 |
DatabaseName | CrossRef PubMed MEDLINE - Academic |
DatabaseTitle | CrossRef PubMed MEDLINE - Academic |
DatabaseTitleList | CrossRef PubMed MEDLINE - Academic |
Database_xml | – sequence: 1 dbid: NPM name: PubMed url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed sourceTypes: Index Database |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Medicine |
EISSN | 1423-0356 |
EndPage | 150 |
ExternalDocumentID | A633355439 31352444 10_1159_000498951 498951 |
Genre | Journal Article |
GeographicLocations | Australia |
GeographicLocations_xml | – name: Australia |
GroupedDBID | --- .GJ .XZ 0R~ 0~5 0~B 123 29P 30W 327 34G 36B 39C 3O. 3V. 4.4 53G 5RE 7RQ 7RV 7X7 88E 8AO 8FI 8FJ 8G5 8UI AAWTL AAYIC ABJNI ABPAZ ABUWG ACGFS ACPSR ADAGL ADBBV AENEX AEYAO AFJJK AFKRA AHMBA ALDHI ALIPV ALMA_UNASSIGNED_HOLDINGS APPQY AZPMC AZQEC BENPR BKEYQ BPHCQ BVXVI C45 CAG CCPQU COF CS3 CYUIP DU5 DWQXO E0A EBS EJD EMB EMOBN EX3 F5P FB. FYUFA GNUQQ GUQSH HMCUK HZ~ IAO IHR IHW IY7 KUZGX L7B M1P M2O N9A NAPCQ O1H O9- OVD PQQKQ PROAC PSQYO RIG RKO RXVBD SV3 TEORI UJ6 UKHRP WOW ZGI ZXP AAYXX ABBTS ABWCG ACQXL AFSIO AHFRZ CITATION ITC PHGZM PHGZT NPM 7X8 |
ID | FETCH-LOGICAL-c498t-1ed14ab51d725daf702bb7d0740c580b23b6632a3427168d6494f57cbb8ee49e3 |
ISSN | 0025-7931 1423-0356 |
IngestDate | Fri Jul 11 06:41:48 EDT 2025 Wed Mar 19 01:49:28 EDT 2025 Sat Mar 08 18:23:53 EST 2025 Thu May 22 21:20:34 EDT 2025 Wed Feb 19 02:30:41 EST 2025 Tue Jul 01 05:01:22 EDT 2025 Thu Apr 24 23:03:33 EDT 2025 Thu Sep 05 20:30:39 EDT 2024 Thu Aug 29 12:04:36 EDT 2024 |
IsPeerReviewed | true |
IsScholarly | true |
Issue | 2 |
Keywords | Lung biopsy Solitary pulmonary nodule Lung cancer Robotic bronchoscopy |
Language | English |
License | Copyright: All rights reserved. No part of this publication may be translated into other languages, reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, microcopying, or by any information storage and retrieval system, without permission in writing from the publisher. https://www.karger.com/Services/SiteLicenses 2019 S. Karger AG, Basel. |
LinkModel | OpenURL |
MergedId | FETCHMERGED-LOGICAL-c498t-1ed14ab51d725daf702bb7d0740c580b23b6632a3427168d6494f57cbb8ee49e3 |
Notes | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
PMID | 31352444 |
PQID | 2266333031 |
PQPubID | 23479 |
PageCount | 9 |
ParticipantIDs | crossref_citationtrail_10_1159_000498951 gale_infotracacademiconefile_A633355439 crossref_primary_10_1159_000498951 pubmed_primary_31352444 gale_healthsolutions_A633355439 karger_primary_498951 proquest_miscellaneous_2266333031 gale_infotracmisc_A633355439 |
ProviderPackageCode | CITATION AAYXX |
PublicationCentury | 2000 |
PublicationDate | 2019-08-01 |
PublicationDateYYYYMMDD | 2019-08-01 |
PublicationDate_xml | – month: 08 year: 2019 text: 2019-08-01 day: 01 |
PublicationDecade | 2010 |
PublicationPlace | Basel, Switzerland |
PublicationPlace_xml | – name: Basel, Switzerland – name: Switzerland |
PublicationTitle | Respiration |
PublicationTitleAlternate | Respiration |
PublicationYear | 2019 |
Publisher | S. Karger AG |
Publisher_xml | – name: S. Karger AG |
References | Rojas-Solano JR, Ugalde-Gamboa L, Machuzak M. Robotic Bronchoscopy for Diagnosis of Suspected Lung Cancer: A Feasibility Study. J Bronchology Interv Pulmonol. 2018Jul;25(3):168–75. 10.1097/LBR.0000000000000499297624611944-6586 Wang Memoli JS, Nietert PJ, Silvestri GA. Meta-analysis of guided bronchoscopy for the evaluation of the pulmonary nodule. Chest. 2012Aug;142(2):385–93. 10.1378/chest.11-1764219800590012-3692 Rivera MP, Mehta AC, Wahidi MM. Establishing the diagnosis of lung cancer: Diagnosis and management of lung cancer, 3rd ed: American College of Chest Physicians evidence-based clinical practice guidelines. Chest. 2013;143(5 Suppl):e142S-e65S. Eberhardt R, Anantham D, Ernst A, Feller-Kopman D, Herth F. Multimodality bronchoscopic diagnosis of peripheral lung lesions: a randomized controlled trial. Am J Respir Crit Care Med. 2007Jul;176(1):36–41. 10.1164/rccm.200612-1866OC173798501073-449X Nakai T, Matsumoto Y, Suzuk F, Tsuchida T, Izumo T. Predictive factors for a successful diagnostic bronchoscopy of ground-glass nodules. Ann Thorac Med. 2017Jul-Sep;12(3):171–6. 10.4103/atm.ATM_428_16288084881817-1737 Oshige M, Shirakawa T, Nakamura M, Mineshita M, Kurimoto N, Miyazawa T, et al.. Clinical application of virtual bronchoscopic navigation system for peripheral lung lesions. J Bronchology Interv Pulmonol. 2011Apr;18(2):196–202. 10.1097/LBR.0b013e3182198f24231690971944-6586 MedCalc Statistical Software version 18.5 (MedCalc Software bvba, Ostend, Belgium; http://www.medcalc.org; 2018) Herth FJ, Eberhardt R. Endobronchial ultrasound and electromagnetic navigation bronchoscopy in the diagnosis of peripheral lung lesions. Expert Opin Med Diagn. 2008May;2(5):461–6. 10.1517/17530059.2.5.461234957351753-0059 Fintelmann FJ, Gottumukkala RV, McDermott S, Gilman MD, Lennes IT, Shepard JO. Lung Cancer Screening: Why, When, and How. Radiol Clin North Am. 2017Nov;55(6):1163–81. 10.1016/j.rcl.2017.06.003289915580033-8389 Oki M, Saka H, Ando M, Asano F, Kurimoto N, Morita K, et al.. Ultrathin Bronchoscopy with Multimodal Devices for Peripheral Pulmonary Lesions. A Randomized Trial. Am J Respir Crit Care Med. 2015Aug;192(4):468–76. 10.1164/rccm.201502-0205OC260397921073-449X Wong KY, Tse HN, Pak KK, Wong CC, Lok PS, Chan KC, et al.. Integrated use of virtual bronchoscopy and endobronchial ultrasonography on the diagnosis of peripheral lung lesions. J Bronchology Interv Pulmonol. 2014Jan;21(1):14–20. 10.1097/LBR.0000000000000027244191811944-6586 Eberhardt R, Morgan RK, Ernst A, Beyer T, Herth FJ. Comparison of suction catheter versus forceps biopsy for sampling of solitary pulmonary nodules guided by electromagnetic navigational bronchoscopy. Respiration. 2010;79(1):54–60. 10.1159/000232394196487331423-0356 Cheng TY, Cramb SM, Baade PD, Youlden DR, Nwogu C, Reid ME. The International Epidemiology of Lung Cancer: Latest Trends, Disparities, and Tumor Characteristics. Journal of thoracic oncology : official publication of the International Association for the Study of Lung Cancer. 2016;11(10):1653-71. Kurimoto N, Miyazawa T, Okimasa S, Maeda A, Oiwa H, Miyazu Y, et al.. Endobronchial ultrasonography using a guide sheath increases the ability to diagnose peripheral pulmonary lesions endoscopically. Chest. 2004Sep;126(3):959–65. 10.1378/chest.126.3.959153647790012-3692 Izumo T, Matsumoto Y, Sasada S, Chavez C, Nakai T, Tsuchida T. Utility of rapid on-site cytologic evaluation during endobronchial ultrasound with a guide sheath for peripheral pulmonary lesions. Jpn J Clin Oncol. 2017Mar;47(3):221–5. 10.1093/jjco/hyw180279800840368-2811 Ishida T, Asano F, Yamazaki K, Shinagawa N, Oizumi S, Moriya H, et al.; Virtual Navigation in Japan Trial Group. Virtual bronchoscopic navigation combined with endobronchial ultrasound to diagnose small peripheral pulmonary lesions: a randomised trial. Thorax. 2011Dec;66(12):1072–7. 10.1136/thx.2010.145490217499840040-6376 Asano F. Advanced bronchoscopy for the diagnosis of peripheral pulmonary lesions. Respir Investig. 2016Jul;54(4):224–9. 10.1016/j.resinv.2015.11.008274248202212-5345 Krochmal R, Arias S, Yarmus L, Feller-Kopman D, Lee H. Diagnosis and management of pulmonary nodules. Expert Rev Respir Med. 2014Dec;8(6):677–91. 10.1586/17476348.2014.948855251523061747-6348 Ost DE, Ernst A, Lei X, Kovitz KL, Benzaquen S, Diaz-Mendoza J, et al.; AQuIRE Bronchoscopy Registry. Diagnostic Yield and Complications of Bronchoscopy for Peripheral Lung Lesions. Results of the AQuIRE Registry. Am J Respir Crit Care Med. 2016Jan;193(1):68–77. 10.1164/rccm.201507-1332OC263671861073-449X Asano F, Aoe M, Ohsaki Y, Okada Y, Sasada S, Sato S, et al.. Complications associated with endobronchial ultrasound-guided transbronchial needle aspiration: a nationwide survey by the Japan Society for Respiratory Endoscopy. Respir Res. 2013May;14(1):50. 10.1186/1465-9921-14-50236634381465-9921 Aberle DR, Adams AM, Berg CD, Black WC, Clapp JD, Fagerstrom RM, et al.; National Lung Screening Trial Research Team. Reduced lung-cancer mortality with low-dose computed tomographic screening. N Engl J Med. 2011Aug;365(5):395–409. 10.1056/NEJMoa1102873217146410028-4793 Gex G, Pralong JA, Combescure C, Seijo L, Rochat T, Soccal PM. Diagnostic yield and safety of electromagnetic navigation bronchoscopy for lung nodules: a systematic review and meta-analysis. Respiration; international review of thoracic diseases. 2014;87(2):165-76. 10.1159/000355710 Minezawa T, Okamura T, Yatsuya H, Yamamoto N, Morikawa S, Yamaguchi T, et al.. Bronchus sign on thin-section computed tomography is a powerful predictive factor for successful transbronchial biopsy using endobronchial ultrasound with a guide sheath for small peripheral lung lesions: a retrospective observational study. BMC Med Imaging. 2015Jun;15(1):21. 10.1186/s12880-015-0060-5260924971471-2342 Oken M, Creech R, Tormey D, Horton J, Davis TE, McFadden ET, et al. Toxicity and response criteria of the Eastern Cooperative Oncology Group. Am J Clin Oncol. 1982 Dec(6);5:649–55. Hayama M, Izumo T, Matsumoto Y, Chavez C, Tsuchida T, Sasada S. Complications with Endobronchial Ultrasound with a Guide Sheath for the Diagnosis of Peripheral Pulmonary Lesions. Respiration. 2015;90(2):129–35. 10.1159/000431383261122971423-0356 ref13 ref12 ref15 ref14 ref20 ref11 ref10 ref21 ref2 ref1 ref17 ref16 ref19 ref18 ref8 ref7 ref9 ref4 ref3 ref6 ref5 |
References_xml | – reference: Fintelmann FJ, Gottumukkala RV, McDermott S, Gilman MD, Lennes IT, Shepard JO. Lung Cancer Screening: Why, When, and How. Radiol Clin North Am. 2017Nov;55(6):1163–81. 10.1016/j.rcl.2017.06.003289915580033-8389 – reference: Eberhardt R, Anantham D, Ernst A, Feller-Kopman D, Herth F. Multimodality bronchoscopic diagnosis of peripheral lung lesions: a randomized controlled trial. Am J Respir Crit Care Med. 2007Jul;176(1):36–41. 10.1164/rccm.200612-1866OC173798501073-449X – reference: Asano F, Aoe M, Ohsaki Y, Okada Y, Sasada S, Sato S, et al.. Complications associated with endobronchial ultrasound-guided transbronchial needle aspiration: a nationwide survey by the Japan Society for Respiratory Endoscopy. Respir Res. 2013May;14(1):50. 10.1186/1465-9921-14-50236634381465-9921 – reference: Kurimoto N, Miyazawa T, Okimasa S, Maeda A, Oiwa H, Miyazu Y, et al.. Endobronchial ultrasonography using a guide sheath increases the ability to diagnose peripheral pulmonary lesions endoscopically. Chest. 2004Sep;126(3):959–65. 10.1378/chest.126.3.959153647790012-3692 – reference: Rivera MP, Mehta AC, Wahidi MM. Establishing the diagnosis of lung cancer: Diagnosis and management of lung cancer, 3rd ed: American College of Chest Physicians evidence-based clinical practice guidelines. Chest. 2013;143(5 Suppl):e142S-e65S. – reference: Krochmal R, Arias S, Yarmus L, Feller-Kopman D, Lee H. Diagnosis and management of pulmonary nodules. Expert Rev Respir Med. 2014Dec;8(6):677–91. 10.1586/17476348.2014.948855251523061747-6348 – reference: Nakai T, Matsumoto Y, Suzuk F, Tsuchida T, Izumo T. Predictive factors for a successful diagnostic bronchoscopy of ground-glass nodules. Ann Thorac Med. 2017Jul-Sep;12(3):171–6. 10.4103/atm.ATM_428_16288084881817-1737 – reference: Oshige M, Shirakawa T, Nakamura M, Mineshita M, Kurimoto N, Miyazawa T, et al.. Clinical application of virtual bronchoscopic navigation system for peripheral lung lesions. J Bronchology Interv Pulmonol. 2011Apr;18(2):196–202. 10.1097/LBR.0b013e3182198f24231690971944-6586 – reference: Ishida T, Asano F, Yamazaki K, Shinagawa N, Oizumi S, Moriya H, et al.; Virtual Navigation in Japan Trial Group. Virtual bronchoscopic navigation combined with endobronchial ultrasound to diagnose small peripheral pulmonary lesions: a randomised trial. Thorax. 2011Dec;66(12):1072–7. 10.1136/thx.2010.145490217499840040-6376 – reference: Rojas-Solano JR, Ugalde-Gamboa L, Machuzak M. Robotic Bronchoscopy for Diagnosis of Suspected Lung Cancer: A Feasibility Study. J Bronchology Interv Pulmonol. 2018Jul;25(3):168–75. 10.1097/LBR.0000000000000499297624611944-6586 – reference: Minezawa T, Okamura T, Yatsuya H, Yamamoto N, Morikawa S, Yamaguchi T, et al.. Bronchus sign on thin-section computed tomography is a powerful predictive factor for successful transbronchial biopsy using endobronchial ultrasound with a guide sheath for small peripheral lung lesions: a retrospective observational study. BMC Med Imaging. 2015Jun;15(1):21. 10.1186/s12880-015-0060-5260924971471-2342 – reference: Hayama M, Izumo T, Matsumoto Y, Chavez C, Tsuchida T, Sasada S. Complications with Endobronchial Ultrasound with a Guide Sheath for the Diagnosis of Peripheral Pulmonary Lesions. Respiration. 2015;90(2):129–35. 10.1159/000431383261122971423-0356 – reference: Cheng TY, Cramb SM, Baade PD, Youlden DR, Nwogu C, Reid ME. The International Epidemiology of Lung Cancer: Latest Trends, Disparities, and Tumor Characteristics. Journal of thoracic oncology : official publication of the International Association for the Study of Lung Cancer. 2016;11(10):1653-71. – reference: Oki M, Saka H, Ando M, Asano F, Kurimoto N, Morita K, et al.. Ultrathin Bronchoscopy with Multimodal Devices for Peripheral Pulmonary Lesions. A Randomized Trial. Am J Respir Crit Care Med. 2015Aug;192(4):468–76. 10.1164/rccm.201502-0205OC260397921073-449X – reference: Aberle DR, Adams AM, Berg CD, Black WC, Clapp JD, Fagerstrom RM, et al.; National Lung Screening Trial Research Team. Reduced lung-cancer mortality with low-dose computed tomographic screening. N Engl J Med. 2011Aug;365(5):395–409. 10.1056/NEJMoa1102873217146410028-4793 – reference: Gex G, Pralong JA, Combescure C, Seijo L, Rochat T, Soccal PM. Diagnostic yield and safety of electromagnetic navigation bronchoscopy for lung nodules: a systematic review and meta-analysis. Respiration; international review of thoracic diseases. 2014;87(2):165-76. 10.1159/000355710 – reference: Izumo T, Matsumoto Y, Sasada S, Chavez C, Nakai T, Tsuchida T. Utility of rapid on-site cytologic evaluation during endobronchial ultrasound with a guide sheath for peripheral pulmonary lesions. Jpn J Clin Oncol. 2017Mar;47(3):221–5. 10.1093/jjco/hyw180279800840368-2811 – reference: Wang Memoli JS, Nietert PJ, Silvestri GA. Meta-analysis of guided bronchoscopy for the evaluation of the pulmonary nodule. Chest. 2012Aug;142(2):385–93. 10.1378/chest.11-1764219800590012-3692 – reference: MedCalc Statistical Software version 18.5 (MedCalc Software bvba, Ostend, Belgium; http://www.medcalc.org; 2018) – reference: Herth FJ, Eberhardt R. Endobronchial ultrasound and electromagnetic navigation bronchoscopy in the diagnosis of peripheral lung lesions. Expert Opin Med Diagn. 2008May;2(5):461–6. 10.1517/17530059.2.5.461234957351753-0059 – reference: Oken M, Creech R, Tormey D, Horton J, Davis TE, McFadden ET, et al. Toxicity and response criteria of the Eastern Cooperative Oncology Group. Am J Clin Oncol. 1982 Dec(6);5:649–55. – reference: Asano F. Advanced bronchoscopy for the diagnosis of peripheral pulmonary lesions. Respir Investig. 2016Jul;54(4):224–9. 10.1016/j.resinv.2015.11.008274248202212-5345 – reference: Ost DE, Ernst A, Lei X, Kovitz KL, Benzaquen S, Diaz-Mendoza J, et al.; AQuIRE Bronchoscopy Registry. Diagnostic Yield and Complications of Bronchoscopy for Peripheral Lung Lesions. Results of the AQuIRE Registry. Am J Respir Crit Care Med. 2016Jan;193(1):68–77. 10.1164/rccm.201507-1332OC263671861073-449X – reference: Wong KY, Tse HN, Pak KK, Wong CC, Lok PS, Chan KC, et al.. Integrated use of virtual bronchoscopy and endobronchial ultrasonography on the diagnosis of peripheral lung lesions. J Bronchology Interv Pulmonol. 2014Jan;21(1):14–20. 10.1097/LBR.0000000000000027244191811944-6586 – reference: Eberhardt R, Morgan RK, Ernst A, Beyer T, Herth FJ. Comparison of suction catheter versus forceps biopsy for sampling of solitary pulmonary nodules guided by electromagnetic navigational bronchoscopy. Respiration. 2010;79(1):54–60. 10.1159/000232394196487331423-0356 – ident: ref7 doi: 10.1097/LBR.0000000000000027 – ident: ref17 doi: 10.4103/atm.ATM_428_16 – ident: ref11 doi: 10.1159/000431383 – ident: ref2 doi: 10.1016/j.rcl.2017.06.003 – ident: ref6 doi: 10.1164/rccm.201502-0205OC – ident: ref19 doi: 10.1159/000232394 – ident: ref8 doi: 10.1186/1465-9921-14-50 – ident: ref16 doi: 10.1186/s12880-015-0060-5 – ident: ref5 doi: 10.1378/chest.11-1764 – ident: ref10 doi: 10.1093/jjco/hyw180 – ident: ref13 doi: 10.1378/chest.126.3.959 – ident: ref3 doi: 10.1136/thx.2010.145490 – ident: ref9 doi: 10.1159/000355710 – ident: ref15 doi: 10.1586/17476348.2014.948855 – ident: ref14 doi: 10.1164/rccm.200612-1866OC – ident: ref20 doi: 10.1164/rccm.201507-1332OC – ident: ref4 doi: 10.1016/j.resinv.2015.11.008 – ident: ref1 doi: 10.1056/NEJMoa1102873 – ident: ref18 doi: 10.1517/17530059.2.5.461 – ident: ref21 doi: 10.1097/LBR.0000000000000499 – ident: ref12 doi: 10.1097/LBR.0b013e3182198f24 |
SSID | ssj0015882 |
Score | 2.5615113 |
Snippet | Background: We tested a new, investigational robotic-assisted bronchoscope system with a remotely controlled catheter to access small peripheral bronchi with... We tested a new, investigational robotic-assisted bronchoscope system with a remotely controlled catheter to access small peripheral bronchi with real-time... |
SourceID | proquest gale pubmed crossref karger |
SourceType | Aggregation Database Index Database Enrichment Source Publisher |
StartPage | 142 |
SubjectTerms | Biopsy Bronchoscopy Diagnosis Electronics in navigation Equipment and supplies Fiber optics Health aspects Interventional Pulmonology Lung cancer Lungs Methods Robotics Technology application |
Title | First Human Use of a New Robotic-Assisted Fiber Optic Sensing Navigation System for Small Peripheral Pulmonary Nodules |
URI | https://karger.com/doi/10.1159/000498951 https://www.ncbi.nlm.nih.gov/pubmed/31352444 https://www.proquest.com/docview/2266333031 |
Volume | 98 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV3db9MwELdYhxAviI8BgTIMQgKpykhiu0keN9SooLWbtlbqW2THDkKUpCrtkPbXc3Zctx1FGrxEkeO6l9zP57vz3Rmhd6SMaaBCBkZOIsFAEYWf0hKMFVkkpJCJCsxhE4Nhtz-mXyZsst7BN9klC3FUXO_MK_kfrkIb8FVnyf4DZ92g0AD3wF-4AofheiseZ99Ad7N--HHjlOcmYvGiFjX09uHjazbKTqYDQzpnM12e9VLHrFdfQbBemfoaWmKYes4m5PDyh96sPgfyTcEB7dibwgvp4LphLZdTG3O4qultd-o3dvMzHRNnT0oxEfOdz2tf6ok-u2l-zaUy7pyM63vn5altoggQ1__l1otRLa2bdgBU8Kra9FTo5Khk5alohCuobn5AmC19vaPNSuQ02UBetCFew6YS159in6VNnCRNk9QWsN0qrT08y7Px6Wk-6k1Ge2g_ApsiaqH9k97w_MJtOrHEnC3mSLKFqGDwj27oLfXFLuJ3v-ug_fnfbRSjq4weogfWyMDHDWIeoTuqeozuDWwYxRN0ZYCDDXAwAAfXJeYYgINvAgcb4GADHGyBg9fAwQ1wMAAHG-DgNXCwAw62wDlA46w3-tT37QEcfgFvu_BDJUPKBQtlHDHJyziIhIglaJ1BwZJARESAwhpxQiMwuxPZpTDPWVwIkShFU0WeolZVV-o5wopRnqiYd0FVomUZ8q4ISsIUWMSClpR76MPqu-aFrU6vD0mZ5sZKZWnuWOCht67rrCnJsqvTa82cvMkmdpM9P-4SolVsknrovemhgQT_VHCbjwL06pJoWz3bWz1BABdbjw8aADhqViS0b7SDTG0e5TNZeujNCi65HlEHO1aqXv7MwSLSg8Ny66FnDY7cECQEi4lS-uIWv36J7q-nYRu1FvOlegUq9EIcor14Eh_aCfAbKULGgA |
linkProvider | ProQuest |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=First+Human+Use+of+a+New+Robotic-Assisted+Fiber+Optic+Sensing+Navigation+System+for+Small+Peripheral+Pulmonary+Nodules&rft.jtitle=Respiration&rft.au=Fielding%2C+David+I+K&rft.au=Bashirzadeh%2C+Farzad&rft.au=Son%2C+Jung+Hwa&rft.au=Todman%2C+Maryann&rft.date=2019-08-01&rft.issn=1423-0356&rft.eissn=1423-0356&rft.volume=98&rft.issue=2&rft.spage=142&rft_id=info:doi/10.1159%2F000498951&rft.externalDBID=NO_FULL_TEXT |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0025-7931&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0025-7931&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0025-7931&client=summon |