Heart Rate Estimation Considering Reconstructed Signal Features Based on Variational Mode Decomposition via Multiple-Input Multiple-Output Frequency Modulated Continuous Wave Radar

Accurate heart rate estimation using Doppler radar and Frequency Modulated Continuous Wave (FMCW) radar is highly valued for privacy protection and the ability to measure through clothing. Conventional methods struggle to isolate the heartbeat from respiration and body motion. This paper introduces...

Full description

Saved in:
Bibliographic Details
Published inSensors (Basel, Switzerland) Vol. 24; no. 21; p. 6809
Main Authors Nakatani, Sara, Bouazizi, Mondher, Ohtsuki, Tomoaki
Format Journal Article
LanguageEnglish
Published Switzerland MDPI AG 01.11.2024
MDPI
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Accurate heart rate estimation using Doppler radar and Frequency Modulated Continuous Wave (FMCW) radar is highly valued for privacy protection and the ability to measure through clothing. Conventional methods struggle to isolate the heartbeat from respiration and body motion. This paper introduces a novel heart rate estimation method using Variational Mode Decomposition (VMD) via Multiple-Input Multiple-Output (MIMO) FMCW radar. The proposed method first estimates human positions within the radar’s coverage, reducing noise by focusing on signals from these positions. The signal is then decomposed into multiple Intrinsic Mode Function (IMF) signals using VMD, and the heartbeat-specific IMF is extracted based on its center frequency. The heart rate signal is reconstructed using weighted addition of IMF signals for each radar cell, with cells defined by specific angles and distances within the coverage area. Peak detection is used to estimate heart rate from these reconstructed signals. To ensure accuracy, the method selects the heart rate estimate with the highest energy and periodicity for the first four time windows. From the fifth time window onward, it selects the estimate closest to the average of the previous four, minimizing extraneous variations. Experiments conducted with one and two subjects showed promising results. In case 1, with one subject, the method achieved a Mean Absolute Error (MAE) of 2.54 BPM and an exclusion rate of 0.94% using MIMO FMCW radar, compared to 4.72% with Doppler radar. In case 2, with two subjects, the method achieved an MAE of 2.28 BPM, confirming accurate simultaneous heart rate estimation.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
ISSN:1424-8220
1424-8220
DOI:10.3390/s24216809