A motion-classification strategy based on sEMG-EEG signal combination for upper-limb amputees

Most of the modern motorized prostheses are controlled with the surface electromyography (sEMG) recorded on the residual muscles of amputated limbs. However, the residual muscles are usually limited, especially after above-elbow amputations, which would not provide enough sEMG for the control of pro...

Full description

Saved in:
Bibliographic Details
Published inJournal of neuroengineering and rehabilitation Vol. 14; no. 1; p. 2
Main Authors Li, Xiangxin, Samuel, Oluwarotimi Williams, Zhang, Xu, Wang, Hui, Fang, Peng, Li, Guanglin
Format Journal Article
LanguageEnglish
Published England BioMed Central Ltd 07.01.2017
BioMed Central
Subjects
Online AccessGet full text

Cover

Loading…
Abstract Most of the modern motorized prostheses are controlled with the surface electromyography (sEMG) recorded on the residual muscles of amputated limbs. However, the residual muscles are usually limited, especially after above-elbow amputations, which would not provide enough sEMG for the control of prostheses with multiple degrees of freedom. Signal fusion is a possible approach to solve the problem of insufficient control commands, where some non-EMG signals are combined with sEMG signals to provide sufficient information for motion intension decoding. In this study, a motion-classification method that combines sEMG and electroencephalography (EEG) signals were proposed and investigated, in order to improve the control performance of upper-limb prostheses. Four transhumeral amputees without any form of neurological disease were recruited in the experiments. Five motion classes including hand-open, hand-close, wrist-pronation, wrist-supination, and no-movement were specified. During the motion performances, sEMG and EEG signals were simultaneously acquired from the skin surface and scalp of the amputees, respectively. The two types of signals were independently preprocessed and then combined as a parallel control input. Four time-domain features were extracted and fed into a classifier trained by the Linear Discriminant Analysis (LDA) algorithm for motion recognition. In addition, channel selections were performed by using the Sequential Forward Selection (SFS) algorithm to optimize the performance of the proposed method. The classification performance achieved by the fusion of sEMG and EEG signals was significantly better than that obtained by single signal source of either sEMG or EEG. An increment of more than 14% in classification accuracy was achieved when using a combination of 32-channel sEMG and 64-channel EEG. Furthermore, based on the SFS algorithm, two optimized electrode arrangements (10-channel sEMG + 10-channel EEG, 10-channel sEMG + 20-channel EEG) were obtained with classification accuracies of 84.2 and 87.0%, respectively, which were about 7.2 and 10% higher than the accuracy by using only 32-channel sEMG input. This study demonstrated the feasibility of fusing sEMG and EEG signals towards improving motion classification accuracy for above-elbow amputees, which might enhance the control performances of multifunctional myoelectric prostheses in clinical application. The study was approved by the ethics committee of Institutional Review Board of Shenzhen Institutes of Advanced Technology, and the reference number is SIAT-IRB-150515-H0077.
AbstractList Most of the modern motorized prostheses are controlled with the surface electromyography (sEMG) recorded on the residual muscles of amputated limbs. However, the residual muscles are usually limited, especially after above-elbow amputations, which would not provide enough sEMG for the control of prostheses with multiple degrees of freedom. Signal fusion is a possible approach to solve the problem of insufficient control commands, where some non-EMG signals are combined with sEMG signals to provide sufficient information for motion intension decoding. In this study, a motion-classification method that combines sEMG and electroencephalography (EEG) signals were proposed and investigated, in order to improve the control performance of upper-limb prostheses.BACKGROUNDMost of the modern motorized prostheses are controlled with the surface electromyography (sEMG) recorded on the residual muscles of amputated limbs. However, the residual muscles are usually limited, especially after above-elbow amputations, which would not provide enough sEMG for the control of prostheses with multiple degrees of freedom. Signal fusion is a possible approach to solve the problem of insufficient control commands, where some non-EMG signals are combined with sEMG signals to provide sufficient information for motion intension decoding. In this study, a motion-classification method that combines sEMG and electroencephalography (EEG) signals were proposed and investigated, in order to improve the control performance of upper-limb prostheses.Four transhumeral amputees without any form of neurological disease were recruited in the experiments. Five motion classes including hand-open, hand-close, wrist-pronation, wrist-supination, and no-movement were specified. During the motion performances, sEMG and EEG signals were simultaneously acquired from the skin surface and scalp of the amputees, respectively. The two types of signals were independently preprocessed and then combined as a parallel control input. Four time-domain features were extracted and fed into a classifier trained by the Linear Discriminant Analysis (LDA) algorithm for motion recognition. In addition, channel selections were performed by using the Sequential Forward Selection (SFS) algorithm to optimize the performance of the proposed method.METHODSFour transhumeral amputees without any form of neurological disease were recruited in the experiments. Five motion classes including hand-open, hand-close, wrist-pronation, wrist-supination, and no-movement were specified. During the motion performances, sEMG and EEG signals were simultaneously acquired from the skin surface and scalp of the amputees, respectively. The two types of signals were independently preprocessed and then combined as a parallel control input. Four time-domain features were extracted and fed into a classifier trained by the Linear Discriminant Analysis (LDA) algorithm for motion recognition. In addition, channel selections were performed by using the Sequential Forward Selection (SFS) algorithm to optimize the performance of the proposed method.The classification performance achieved by the fusion of sEMG and EEG signals was significantly better than that obtained by single signal source of either sEMG or EEG. An increment of more than 14% in classification accuracy was achieved when using a combination of 32-channel sEMG and 64-channel EEG. Furthermore, based on the SFS algorithm, two optimized electrode arrangements (10-channel sEMG + 10-channel EEG, 10-channel sEMG + 20-channel EEG) were obtained with classification accuracies of 84.2 and 87.0%, respectively, which were about 7.2 and 10% higher than the accuracy by using only 32-channel sEMG input.RESULTSThe classification performance achieved by the fusion of sEMG and EEG signals was significantly better than that obtained by single signal source of either sEMG or EEG. An increment of more than 14% in classification accuracy was achieved when using a combination of 32-channel sEMG and 64-channel EEG. Furthermore, based on the SFS algorithm, two optimized electrode arrangements (10-channel sEMG + 10-channel EEG, 10-channel sEMG + 20-channel EEG) were obtained with classification accuracies of 84.2 and 87.0%, respectively, which were about 7.2 and 10% higher than the accuracy by using only 32-channel sEMG input.This study demonstrated the feasibility of fusing sEMG and EEG signals towards improving motion classification accuracy for above-elbow amputees, which might enhance the control performances of multifunctional myoelectric prostheses in clinical application.CONCLUSIONSThis study demonstrated the feasibility of fusing sEMG and EEG signals towards improving motion classification accuracy for above-elbow amputees, which might enhance the control performances of multifunctional myoelectric prostheses in clinical application.The study was approved by the ethics committee of Institutional Review Board of Shenzhen Institutes of Advanced Technology, and the reference number is SIAT-IRB-150515-H0077.TRIAL REGISTRATIONThe study was approved by the ethics committee of Institutional Review Board of Shenzhen Institutes of Advanced Technology, and the reference number is SIAT-IRB-150515-H0077.
Most of the modern motorized prostheses are controlled with the surface electromyography (sEMG) recorded on the residual muscles of amputated limbs. However, the residual muscles are usually limited, especially after above-elbow amputations, which would not provide enough sEMG for the control of prostheses with multiple degrees of freedom. Signal fusion is a possible approach to solve the problem of insufficient control commands, where some non-EMG signals are combined with sEMG signals to provide sufficient information for motion intension decoding. In this study, a motion-classification method that combines sEMG and electroencephalography (EEG) signals were proposed and investigated, in order to improve the control performance of upper-limb prostheses. Four transhumeral amputees without any form of neurological disease were recruited in the experiments. Five motion classes including hand-open, hand-close, wrist-pronation, wrist-supination, and no-movement were specified. During the motion performances, sEMG and EEG signals were simultaneously acquired from the skin surface and scalp of the amputees, respectively. The two types of signals were independently preprocessed and then combined as a parallel control input. Four time-domain features were extracted and fed into a classifier trained by the Linear Discriminant Analysis (LDA) algorithm for motion recognition. In addition, channel selections were performed by using the Sequential Forward Selection (SFS) algorithm to optimize the performance of the proposed method. The classification performance achieved by the fusion of sEMG and EEG signals was significantly better than that obtained by single signal source of either sEMG or EEG. An increment of more than 14% in classification accuracy was achieved when using a combination of 32-channel sEMG and 64-channel EEG. Furthermore, based on the SFS algorithm, two optimized electrode arrangements (10-channel sEMG + 10-channel EEG, 10-channel sEMG + 20-channel EEG) were obtained with classification accuracies of 84.2 and 87.0%, respectively, which were about 7.2 and 10% higher than the accuracy by using only 32-channel sEMG input. This study demonstrated the feasibility of fusing sEMG and EEG signals towards improving motion classification accuracy for above-elbow amputees, which might enhance the control performances of multifunctional myoelectric prostheses in clinical application.
Background Most of the modern motorized prostheses are controlled with the surface electromyography (sEMG) recorded on the residual muscles of amputated limbs. However, the residual muscles are usually limited, especially after above-elbow amputations, which would not provide enough sEMG for the control of prostheses with multiple degrees of freedom. Signal fusion is a possible approach to solve the problem of insufficient control commands, where some non-EMG signals are combined with sEMG signals to provide sufficient information for motion intension decoding. In this study, a motion-classification method that combines sEMG and electroencephalography (EEG) signals were proposed and investigated, in order to improve the control performance of upper-limb prostheses. Methods Four transhumeral amputees without any form of neurological disease were recruited in the experiments. Five motion classes including hand-open, hand-close, wrist-pronation, wrist-supination, and no-movement were specified. During the motion performances, sEMG and EEG signals were simultaneously acquired from the skin surface and scalp of the amputees, respectively. The two types of signals were independently preprocessed and then combined as a parallel control input. Four time-domain features were extracted and fed into a classifier trained by the Linear Discriminant Analysis (LDA) algorithm for motion recognition. In addition, channel selections were performed by using the Sequential Forward Selection (SFS) algorithm to optimize the performance of the proposed method. Results The classification performance achieved by the fusion of sEMG and EEG signals was significantly better than that obtained by single signal source of either sEMG or EEG. An increment of more than 14% in classification accuracy was achieved when using a combination of 32-channel sEMG and 64-channel EEG. Furthermore, based on the SFS algorithm, two optimized electrode arrangements (10-channel sEMG + 10-channel EEG, 10-channel sEMG + 20-channel EEG) were obtained with classification accuracies of 84.2 and 87.0%, respectively, which were about 7.2 and 10% higher than the accuracy by using only 32-channel sEMG input. Conclusions This study demonstrated the feasibility of fusing sEMG and EEG signals towards improving motion classification accuracy for above-elbow amputees, which might enhance the control performances of multifunctional myoelectric prostheses in clinical application. Trial registration The study was approved by the ethics committee of Institutional Review Board of Shenzhen Institutes of Advanced Technology, and the reference number is SIAT-IRB-150515-H0077. Keywords: Amputee, EEG, Hybrid interface, Motion classification, Multifunctional prosthesis, Pattern recognition, Rehabilitation, sEMG, Signal Fusion
Most of the modern motorized prostheses are controlled with the surface electromyography (sEMG) recorded on the residual muscles of amputated limbs. However, the residual muscles are usually limited, especially after above-elbow amputations, which would not provide enough sEMG for the control of prostheses with multiple degrees of freedom. Signal fusion is a possible approach to solve the problem of insufficient control commands, where some non-EMG signals are combined with sEMG signals to provide sufficient information for motion intension decoding. In this study, a motion-classification method that combines sEMG and electroencephalography (EEG) signals were proposed and investigated, in order to improve the control performance of upper-limb prostheses. Four transhumeral amputees without any form of neurological disease were recruited in the experiments. Five motion classes including hand-open, hand-close, wrist-pronation, wrist-supination, and no-movement were specified. During the motion performances, sEMG and EEG signals were simultaneously acquired from the skin surface and scalp of the amputees, respectively. The two types of signals were independently preprocessed and then combined as a parallel control input. Four time-domain features were extracted and fed into a classifier trained by the Linear Discriminant Analysis (LDA) algorithm for motion recognition. In addition, channel selections were performed by using the Sequential Forward Selection (SFS) algorithm to optimize the performance of the proposed method. The classification performance achieved by the fusion of sEMG and EEG signals was significantly better than that obtained by single signal source of either sEMG or EEG. An increment of more than 14% in classification accuracy was achieved when using a combination of 32-channel sEMG and 64-channel EEG. Furthermore, based on the SFS algorithm, two optimized electrode arrangements (10-channel sEMG + 10-channel EEG, 10-channel sEMG + 20-channel EEG) were obtained with classification accuracies of 84.2 and 87.0%, respectively, which were about 7.2 and 10% higher than the accuracy by using only 32-channel sEMG input. This study demonstrated the feasibility of fusing sEMG and EEG signals towards improving motion classification accuracy for above-elbow amputees, which might enhance the control performances of multifunctional myoelectric prostheses in clinical application. The study was approved by the ethics committee of Institutional Review Board of Shenzhen Institutes of Advanced Technology, and the reference number is SIAT-IRB-150515-H0077.
Background Most of the modern motorized prostheses are controlled with the surface electromyography (sEMG) recorded on the residual muscles of amputated limbs. However, the residual muscles are usually limited, especially after above-elbow amputations, which would not provide enough sEMG for the control of prostheses with multiple degrees of freedom. Signal fusion is a possible approach to solve the problem of insufficient control commands, where some non-EMG signals are combined with sEMG signals to provide sufficient information for motion intension decoding. In this study, a motion-classification method that combines sEMG and electroencephalography (EEG) signals were proposed and investigated, in order to improve the control performance of upper-limb prostheses. Methods Four transhumeral amputees without any form of neurological disease were recruited in the experiments. Five motion classes including hand-open, hand-close, wrist-pronation, wrist-supination, and no-movement were specified. During the motion performances, sEMG and EEG signals were simultaneously acquired from the skin surface and scalp of the amputees, respectively. The two types of signals were independently preprocessed and then combined as a parallel control input. Four time-domain features were extracted and fed into a classifier trained by the Linear Discriminant Analysis (LDA) algorithm for motion recognition. In addition, channel selections were performed by using the Sequential Forward Selection (SFS) algorithm to optimize the performance of the proposed method. Results The classification performance achieved by the fusion of sEMG and EEG signals was significantly better than that obtained by single signal source of either sEMG or EEG. An increment of more than 14% in classification accuracy was achieved when using a combination of 32-channel sEMG and 64-channel EEG. Furthermore, based on the SFS algorithm, two optimized electrode arrangements (10-channel sEMG + 10-channel EEG, 10-channel sEMG + 20-channel EEG) were obtained with classification accuracies of 84.2 and 87.0%, respectively, which were about 7.2 and 10% higher than the accuracy by using only 32-channel sEMG input. Conclusions This study demonstrated the feasibility of fusing sEMG and EEG signals towards improving motion classification accuracy for above-elbow amputees, which might enhance the control performances of multifunctional myoelectric prostheses in clinical application.
ArticleNumber 2
Audience Academic
Author Samuel, Oluwarotimi Williams
Fang, Peng
Wang, Hui
Li, Guanglin
Li, Xiangxin
Zhang, Xu
Author_xml – sequence: 1
  givenname: Xiangxin
  surname: Li
  fullname: Li, Xiangxin
– sequence: 2
  givenname: Oluwarotimi Williams
  surname: Samuel
  fullname: Samuel, Oluwarotimi Williams
– sequence: 3
  givenname: Xu
  surname: Zhang
  fullname: Zhang, Xu
– sequence: 4
  givenname: Hui
  surname: Wang
  fullname: Wang, Hui
– sequence: 5
  givenname: Peng
  surname: Fang
  fullname: Fang, Peng
– sequence: 6
  givenname: Guanglin
  surname: Li
  fullname: Li, Guanglin
BackLink https://www.ncbi.nlm.nih.gov/pubmed/28061779$$D View this record in MEDLINE/PubMed
BookMark eNp9ks9vFSEQx4mpsT_0D_BiNvHihcqwsCwXk5fm-TSp8aJHQ1gWnjTsssKuSfvXy_pqbRsjHBiGzwwD8z1FR2McLUIvgZwDtM3bDFS2DBNoMKFA8c0TdAKC1ZgQUh_ds4_Rac5XxWCEs2fomLakASHkCfq2qYY4-zhiE3TO3nmj122V56Rnu7-uOp1tX62e7acd3m53Vfb7UYfKxKHz44F2MVXLNNmEgx-6Sg_TMlubn6OnTodsX9yuZ-jr--2Xiw_48vPu48XmEhsm2YxlTzU4yToJmkrKTUN6C31tdF0G6M5x3lIwpOaCMSO5ZU7QrviFIRx0fYbeHfJOSzfY3tixVB_UlPyg07WK2quHJ6P_rvbxp-IUZCOgJHhzmyDFH4vNsxp8NjYEPdq4ZAUtb7ikwJuCvn6EXsUllQ9ZqYYTKgTnf6m9Dlb50cVyr1mTqg0TjWCklSt1_g-qzN4O3pRmO1_8DwJe3X_o3Qv_NLQAcABMijkn6-4QIGoVjTqIRhXRqFU06qbEiEcxxs-_-1qq8eE_kb8AMLjFMg
CitedBy_id crossref_primary_10_1016_j_irbm_2024_100866
crossref_primary_10_3390_s23125575
crossref_primary_10_1016_j_bspc_2023_105249
crossref_primary_10_3389_fnins_2022_796290
crossref_primary_10_3389_fnbot_2017_00051
crossref_primary_10_3390_s21041504
crossref_primary_10_1186_s12938_019_0677_7
crossref_primary_10_1109_JBHI_2018_2864335
crossref_primary_10_3390_s17071552
crossref_primary_10_1016_j_medntd_2022_100165
crossref_primary_10_1155_2018_8948145
crossref_primary_10_1109_JSEN_2023_3255408
crossref_primary_10_1109_MSP_2021_3057042
crossref_primary_10_1002_acs_3414
crossref_primary_10_1109_ACCESS_2020_2983182
crossref_primary_10_1109_TCDS_2022_3167042
crossref_primary_10_3389_fbioe_2019_00331
crossref_primary_10_3390_app122211475
crossref_primary_10_3390_bioengineering9110634
crossref_primary_10_1016_j_cmpb_2019_04_023
crossref_primary_10_3390_bioengineering10030319
crossref_primary_10_1080_21681163_2023_2250872
crossref_primary_10_1007_s12652_021_03351_1
crossref_primary_10_3389_fnins_2021_783539
crossref_primary_10_1109_TCYB_2021_3122969
crossref_primary_10_1088_1741_2552_ac0586
crossref_primary_10_3390_s22093424
crossref_primary_10_1186_s12984_024_01345_6
crossref_primary_10_3390_s22020680
crossref_primary_10_1109_JSEN_2022_3221417
crossref_primary_10_1016_j_bspc_2022_103754
crossref_primary_10_3390_s19224931
crossref_primary_10_3390_neurosci4030018
crossref_primary_10_1109_JSEN_2024_3471894
crossref_primary_10_3390_s24010070
crossref_primary_10_1186_s12984_019_0610_0
crossref_primary_10_1142_S0219843619410068
crossref_primary_10_1088_1741_2552_aae9d4
crossref_primary_10_1109_JSEN_2020_3037061
crossref_primary_10_1016_j_mseb_2023_117119
crossref_primary_10_3389_fnins_2022_796711
crossref_primary_10_1038_s41598_018_34785_x
crossref_primary_10_3390_electronics8111244
crossref_primary_10_3233_JIFS_179558
crossref_primary_10_1109_ACCESS_2019_2956018
crossref_primary_10_1093_nsr_nwad048
crossref_primary_10_1109_TNSRE_2022_3228514
crossref_primary_10_1109_JSEN_2020_3033256
crossref_primary_10_1109_ACCESS_2022_3158667
crossref_primary_10_1515_bmt_2020_0343
crossref_primary_10_3389_fnins_2025_1532099
crossref_primary_10_1080_2326263X_2022_2029308
crossref_primary_10_1109_ACCESS_2020_3012741
crossref_primary_10_1109_ACCESS_2019_2945059
crossref_primary_10_1109_JBHI_2020_3002329
crossref_primary_10_1016_j_cmpb_2019_105278
crossref_primary_10_1088_1741_2552_abca14
crossref_primary_10_1186_s12911_022_01808_7
crossref_primary_10_1049_cit2_12039
crossref_primary_10_1016_j_bspc_2021_102969
crossref_primary_10_1186_s13634_022_00939_3
crossref_primary_10_3390_s17071597
crossref_primary_10_1007_s00521_020_05536_9
crossref_primary_10_1016_j_sciaf_2023_e01945
crossref_primary_10_1109_JBHI_2022_3159792
crossref_primary_10_1109_ACCESS_2019_2891350
crossref_primary_10_3389_fnins_2021_621885
crossref_primary_10_1002_adfm_202200457
crossref_primary_10_1109_ACCESS_2024_3386554
crossref_primary_10_1109_JSEN_2020_3028697
crossref_primary_10_3390_s24155043
crossref_primary_10_1016_j_biomaterials_2024_122632
crossref_primary_10_1109_JSEN_2022_3169492
crossref_primary_10_1016_j_bbe_2019_07_007
crossref_primary_10_1049_csy2_12009
crossref_primary_10_1109_TNSRE_2020_2981659
crossref_primary_10_1016_j_compeleceng_2025_110094
crossref_primary_10_1155_2017_5090454
crossref_primary_10_1109_JSEN_2021_3119074
crossref_primary_10_3389_fnbot_2020_582728
crossref_primary_10_3390_s22030726
crossref_primary_10_1093_gigascience_giaa098
crossref_primary_10_3389_fnbot_2021_692183
crossref_primary_10_1088_2516_1091_acc625
crossref_primary_10_1007_s11370_017_0239_4
crossref_primary_10_1016_j_bspc_2022_103679
crossref_primary_10_1109_ACCESS_2021_3099973
crossref_primary_10_3389_fneur_2020_560363
crossref_primary_10_1007_s40747_020_00140_9
crossref_primary_10_3389_fnbot_2023_1161187
crossref_primary_10_34133_2021_4675326
crossref_primary_10_3389_fnins_2023_1129049
crossref_primary_10_1007_s10916_019_1364_8
crossref_primary_10_1016_j_bspc_2021_103153
crossref_primary_10_1371_journal_pone_0276921
crossref_primary_10_3389_fnbot_2021_642607
crossref_primary_10_1016_j_bspc_2020_101990
crossref_primary_10_1109_TNSRE_2024_3431025
crossref_primary_10_3389_fnbot_2019_00037
crossref_primary_10_3389_fbioe_2023_1238210
crossref_primary_10_1016_j_heliyon_2023_e18308
crossref_primary_10_1109_JSEN_2022_3220930
crossref_primary_10_3233_NRE_172394
Cites_doi 10.1088/0967-3334/24/2/307
10.1109/TBME.2015.2407491
10.1186/1865-1380-5-35
10.1109/TNSRE.2009.2039619
10.1109/TNSRE.2007.910282
10.1001/jama.2009.116
10.1111/j.1469-8986.2012.01471.x
10.1016/j.jneumeth.2010.07.015
10.1109/TPAMI.2005.159
10.1109/TBME.2008.2008171
10.1111/j.1440-1681.2005.04142.x
10.1038/nature11076
10.1109/TSMC.1974.5408535
10.1109/TBME.2003.813539
10.1109/TBME.2008.2007967
10.1016/j.eswa.2012.01.102
10.1109/10.204774
10.1186/1475-925X-13-102
10.1007/978-3-642-27579-1_77
10.1007/978-3-319-10978-7_1
10.1109/TBME.2011.2161671
10.1016/j.pain.2010.02.020
10.1109/TNSRE.2013.2278411
10.1016/j.jneumeth.2003.10.009
10.1016/j.jelekin.2011.12.012
10.1109/TNSRE.2014.2305111
10.1186/1743-0003-9-74
10.1109/MIS.2015.40
10.1016/j.jelekin.2016.03.005
10.1682/JRRD.2010.09.0177
10.1016/j.clinph.2008.02.001
10.1016/j.cag.2012.10.006
10.1002/9781118628522
10.1093/brain/awr337
10.1186/1743-0003-11-1
10.1109/TBME.2007.897815
10.1109/FSKD.2012.6234336
ContentType Journal Article
Copyright COPYRIGHT 2017 BioMed Central Ltd.
Copyright BioMed Central 2017
The Author(s). 2017
Copyright_xml – notice: COPYRIGHT 2017 BioMed Central Ltd.
– notice: Copyright BioMed Central 2017
– notice: The Author(s). 2017
DBID AAYXX
CITATION
CGR
CUY
CVF
ECM
EIF
NPM
3V.
7QO
7RV
7TB
7TK
7TS
7X7
7XB
88C
88E
8FD
8FE
8FG
8FH
8FI
8FJ
8FK
ABJCF
ABUWG
AFKRA
AZQEC
BBNVY
BENPR
BGLVJ
BHPHI
CCPQU
DWQXO
FR3
FYUFA
GHDGH
GNUQQ
HCIFZ
K9.
KB0
L6V
LK8
M0S
M0T
M1P
M7P
M7S
NAPCQ
P64
PHGZM
PHGZT
PIMPY
PJZUB
PKEHL
PPXIY
PQEST
PQGLB
PQQKQ
PQUKI
PRINS
PTHSS
7X8
5PM
DOI 10.1186/s12984-016-0212-z
DatabaseName CrossRef
Medline
MEDLINE
MEDLINE (Ovid)
MEDLINE
MEDLINE
PubMed
ProQuest Central (Corporate)
Biotechnology Research Abstracts
Nursing & Allied Health Database
Mechanical & Transportation Engineering Abstracts
Neurosciences Abstracts
Physical Education Index
Health & Medical Collection
ProQuest Central (purchase pre-March 2016)
Healthcare Administration Database (Alumni)
Medical Database (Alumni Edition)
Technology Research Database
ProQuest SciTech Collection
ProQuest Technology Collection
ProQuest Natural Science Collection
Hospital Premium Collection
Hospital Premium Collection (Alumni Edition)
ProQuest Central (Alumni) (purchase pre-March 2016)
Materials Science & Engineering Collection
ProQuest Central (Alumni)
ProQuest Central UK/Ireland
ProQuest Central Essentials
Biological Science Collection
ProQuest Central
Technology Collection
Natural Science Collection
ProQuest One
ProQuest Central
Engineering Research Database
Health Research Premium Collection (ProQuest)
Health Research Premium Collection (Alumni)
ProQuest Central Student
SciTech Premium Collection
ProQuest Health & Medical Complete (Alumni)
Nursing & Allied Health Database (Alumni Edition)
ProQuest Engineering Collection
Biological Sciences
ProQuest Health & Medical Collection
Healthcare Administration Database
PML(ProQuest Medical Library)
Biological Science Database
Engineering Database
Nursing & Allied Health Premium
Biotechnology and BioEngineering Abstracts
ProQuest Central Premium
ProQuest One Academic (New)
Publicly Available Content Database
ProQuest Health & Medical Research Collection
ProQuest One Academic Middle East (New)
ProQuest One Health & Nursing
ProQuest One Academic Eastern Edition (DO NOT USE)
ProQuest One Applied & Life Sciences
ProQuest One Academic
ProQuest One Academic UKI Edition
ProQuest Central China
Engineering collection
MEDLINE - Academic
PubMed Central (Full Participant titles)
DatabaseTitle CrossRef
MEDLINE
Medline Complete
MEDLINE with Full Text
PubMed
MEDLINE (Ovid)
Publicly Available Content Database
ProQuest Central Student
ProQuest Central Essentials
SciTech Premium Collection
ProQuest Central China
ProQuest One Applied & Life Sciences
Health Research Premium Collection
Natural Science Collection
Health & Medical Research Collection
Biological Science Collection
ProQuest Central (New)
ProQuest Medical Library (Alumni)
Engineering Collection
Engineering Database
ProQuest Biological Science Collection
ProQuest One Academic Eastern Edition
ProQuest Hospital Collection
ProQuest Technology Collection
Health Research Premium Collection (Alumni)
Biological Science Database
Neurosciences Abstracts
ProQuest Hospital Collection (Alumni)
Biotechnology and BioEngineering Abstracts
Nursing & Allied Health Premium
ProQuest Health & Medical Complete
ProQuest One Academic UKI Edition
ProQuest Health Management (Alumni Edition)
ProQuest Nursing & Allied Health Source (Alumni)
Engineering Research Database
ProQuest One Academic
ProQuest One Academic (New)
Technology Collection
Technology Research Database
ProQuest One Academic Middle East (New)
Mechanical & Transportation Engineering Abstracts
ProQuest Health & Medical Complete (Alumni)
ProQuest Central (Alumni Edition)
ProQuest One Community College
ProQuest One Health & Nursing
ProQuest Natural Science Collection
Physical Education Index
ProQuest Central
ProQuest Health & Medical Research Collection
ProQuest Engineering Collection
Biotechnology Research Abstracts
Health and Medicine Complete (Alumni Edition)
ProQuest Central Korea
ProQuest Health Management
ProQuest Nursing & Allied Health Source
ProQuest SciTech Collection
ProQuest Medical Library
Materials Science & Engineering Collection
ProQuest Central (Alumni)
MEDLINE - Academic
DatabaseTitleList MEDLINE - Academic


MEDLINE
Publicly Available Content Database
Database_xml – sequence: 1
  dbid: NPM
  name: PubMed
  url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed
  sourceTypes: Index Database
– sequence: 2
  dbid: EIF
  name: MEDLINE
  url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search
  sourceTypes: Index Database
– sequence: 3
  dbid: 8FG
  name: ProQuest Technology Collection
  url: https://search.proquest.com/technologycollection1
  sourceTypes: Aggregation Database
DeliveryMethod fulltext_linktorsrc
Discipline Medicine
Engineering
Occupational Therapy & Rehabilitation
Physical Therapy
EISSN 1743-0003
ExternalDocumentID PMC5219671
4312148271
A476740895
28061779
10_1186_s12984_016_0212_z
Genre Journal Article
GrantInformation_xml – fundername: ;
  grantid: 51275101
– fundername: ;
  grantid: 2014A050503052
– fundername: ;
  grantid: 2013CB329505
– fundername: ;
  grantid: 2014A030306029
– fundername: ;
  grantid: 2015TQ01C399
– fundername: ;
  grantid: 61135004
– fundername: ;
  grantid: 61203209
– fundername: ;
  grantid: 91420301
– fundername: ;
  grantid: KQCX2015033117354152
GroupedDBID ---
0R~
29L
2QV
2WC
53G
5GY
5VS
7RV
7X7
88E
8FE
8FG
8FH
8FI
8FJ
AAFWJ
AAJSJ
AASML
AAWTL
AAYXX
ABDBF
ABJCF
ABUWG
ACGFO
ACGFS
ACIWK
ACPRK
ACUHS
ADBBV
ADRAZ
ADUKV
AENEX
AFKRA
AFPKN
AFRAH
AHBYD
AHMBA
AHSBF
AHYZX
ALIPV
ALMA_UNASSIGNED_HOLDINGS
AMKLP
AMTXH
AOIJS
AQUVI
BAPOH
BAWUL
BBNVY
BCNDV
BENPR
BFQNJ
BGLVJ
BHPHI
BMC
BPHCQ
BVXVI
C6C
CCPQU
CITATION
CS3
DIK
DU5
E3Z
EBD
EBLON
EBS
EJD
ESX
F5P
FYUFA
GROUPED_DOAJ
GX1
H13
HCIFZ
HMCUK
HYE
I-F
IAO
IHR
INH
INR
IPY
ITC
KQ8
L6V
LK8
M0T
M1P
M48
M7P
M7S
ML0
M~E
NAPCQ
O5R
O5S
OK1
OVT
P2P
PGMZT
PHGZM
PHGZT
PIMPY
PQQKQ
PROAC
PSQYO
PTHSS
RBZ
RNS
ROL
RPM
RSV
SBL
SOJ
TR2
TUS
UKHRP
WOQ
WOW
XSB
~8M
-A0
3V.
ACRMQ
ADINQ
C24
CGR
CUY
CVF
ECM
EIF
NPM
PMFND
7QO
7TB
7TK
7TS
7XB
8FD
8FK
AZQEC
DWQXO
FR3
GNUQQ
K9.
P64
PJZUB
PKEHL
PPXIY
PQEST
PQGLB
PQUKI
PRINS
7X8
5PM
ID FETCH-LOGICAL-c494t-9d2a1f94b91a2925c60de1d3ca33331abf55821c035744c95e4f72babf7c051a3
IEDL.DBID M48
ISSN 1743-0003
IngestDate Thu Aug 21 18:23:52 EDT 2025
Fri Jul 11 04:35:22 EDT 2025
Fri Jul 25 19:10:33 EDT 2025
Tue Jun 17 21:36:41 EDT 2025
Tue Jun 10 20:25:24 EDT 2025
Thu Jan 02 22:25:09 EST 2025
Thu Apr 24 23:05:26 EDT 2025
Tue Jul 01 02:19:55 EDT 2025
IsDoiOpenAccess true
IsOpenAccess true
IsPeerReviewed true
IsScholarly true
Issue 1
Keywords Multifunctional prosthesis
Motion classification
Hybrid interface
Signal Fusion
Amputee
EEG
sEMG
Pattern recognition
Rehabilitation
Language English
License Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
LinkModel DirectLink
MergedId FETCHMERGED-LOGICAL-c494t-9d2a1f94b91a2925c60de1d3ca33331abf55821c035744c95e4f72babf7c051a3
Notes ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
OpenAccessLink http://journals.scholarsportal.info/openUrl.xqy?doi=10.1186/s12984-016-0212-z
PMID 28061779
PQID 1865027755
PQPubID 55356
ParticipantIDs pubmedcentral_primary_oai_pubmedcentral_nih_gov_5219671
proquest_miscellaneous_1856592156
proquest_journals_1865027755
gale_infotracmisc_A476740895
gale_infotracacademiconefile_A476740895
pubmed_primary_28061779
crossref_primary_10_1186_s12984_016_0212_z
crossref_citationtrail_10_1186_s12984_016_0212_z
ProviderPackageCode CITATION
AAYXX
PublicationCentury 2000
PublicationDate 2017-01-07
PublicationDateYYYYMMDD 2017-01-07
PublicationDate_xml – month: 01
  year: 2017
  text: 2017-01-07
  day: 07
PublicationDecade 2010
PublicationPlace England
PublicationPlace_xml – name: England
– name: London
PublicationTitle Journal of neuroengineering and rehabilitation
PublicationTitleAlternate J Neuroeng Rehabil
PublicationYear 2017
Publisher BioMed Central Ltd
BioMed Central
Publisher_xml – name: BioMed Central Ltd
– name: BioMed Central
References E Raffin (212_CR22) 2012; 135
H Daley (212_CR33) 2012; 22
H Nolan (212_CR20) 2010; 192
X Li (212_CR4) 2016; 28
D Farina (212_CR5) 2014; 22
212_CR12
H Huang (212_CR40) 2008; 16
A Delorme (212_CR19) 2004; 134
K Englehart (212_CR24) 2003; 50
L Pan (212_CR32) 2015; 62
S Debener (212_CR17) 2012; 49
Y Geng (212_CR34) 2014; 13
P Fang (212_CR16) 2015; 30
A Phinyomark (212_CR28) 2012; 39
J Lobo-Prat (212_CR2) 2014; 11
N Jiang (212_CR3) 2009; 56
S Herrmann (212_CR15) 2011; 6928
B Hudgins (212_CR26) 1993; 40
AE Schultz (212_CR1) 2011; 3
Y Geng (212_CR6) 2012; 9
M Diers (212_CR21) 2010; 149
R Boostani (212_CR25) 2003; 24
212_CR27
L Liu (212_CR37) 2013; 37
P Geethanjali (212_CR29) 2012
LJ Hargrove (212_CR31) 2009; 56
A Omurtag (212_CR41) 2012; 5
H Huang (212_CR13) 2011; 58
HC Peng (212_CR38) 2005; 27
LR Hochberg (212_CR10) 2012; 485
G Li (212_CR23) 2010; 18
TM Cover (212_CR39) 1974; SMC-4
E Scheme (212_CR8) 2011; 48
A Woodhouse (212_CR36) 2005; 32
N Jiang (212_CR18) 2014; 22
BR Greene (212_CR30) 2008; 119
TD Lalitharatne (212_CR14) 2013; 4
TA Kuiken (212_CR7) 2009; 301
GR Müller-Putz (212_CR11) 2008; 55
H Wang (212_CR35) 2015
212_CR9
12812417 - Physiol Meas. 2003 May;24(2):309-19
26737014 - Conf Proc IEEE Eng Med Biol Soc. 2015 ;2015 :3367-70
25730820 - IEEE Trans Biomed Eng. 2015 Aug;62(8):1927-36
22345089 - Brain. 2012 Feb;135(Pt 2):582-95
20654646 - J Neurosci Methods. 2010 Sep 30;192(1):152-62
20071269 - IEEE Trans Neural Syst Rehabil Eng. 2010 Apr;18(2):185-92
27093136 - J Electromyogr Kinesiol. 2016 Jun;28:90-8
25060509 - Biomed Eng Online. 2014 Jul 25;13:102
20359825 - Pain. 2010 May;149(2):296-304
23036049 - J Neuroeng Rehabil. 2012 Oct 05;9:74
23006616 - Int J Emerg Med. 2012 Sep 24;5(1):35
25570515 - Conf Proc IEEE Eng Med Biol Soc. 2014;2014:2569-72
22596161 - Nature. 2012 May 16;485(7398):372-5
12848352 - IEEE Trans Biomed Eng. 2003 Jul;50(7):848-54
21938652 - J Rehabil Res Dev. 2011;48(6):643-59
23996582 - IEEE Trans Neural Syst Rehabil Eng. 2014 May;22(3):501-10
19272889 - IEEE Trans Biomed Eng. 2009 Apr;56(4):1070-80
15730449 - Clin Exp Pharmacol Physiol. 2005 Jan-Feb;32(1-2):132-4
22269773 - J Electromyogr Kinesiol. 2012 Jun;22(3):478-84
15102499 - J Neurosci Methods. 2004 Mar 15;134(1):9-21
21257135 - PM R. 2011 Jan;3(1):55-67
24760934 - IEEE Trans Neural Syst Rehabil Eng. 2014 Jul;22(4):797-809
23013047 - Psychophysiology. 2012 Nov;49(11):1617-21
25516421 - J Neuroeng Rehabil. 2014 Dec 17;11:168
21768042 - IEEE Trans Biomed Eng. 2011 Oct;58(10):2867-75
19473932 - IEEE Trans Biomed Eng. 2009 May;56(5):1407-14
18381249 - Clin Neurophysiol. 2008 Jun;119(6):1248-61
8468080 - IEEE Trans Biomed Eng. 1993 Jan;40(1):82-94
18232384 - IEEE Trans Biomed Eng. 2008 Jan;55(1):361-4
19211469 - JAMA. 2009 Feb 11;301(6):619-28
16119262 - IEEE Trans Pattern Anal Mach Intell. 2005 Aug;27(8):1226-38
18303804 - IEEE Trans Neural Syst Rehabil Eng. 2008 Feb;16(1):37-45
References_xml – volume: 24
  start-page: 309
  year: 2003
  ident: 212_CR25
  publication-title: Physiol Meas
  doi: 10.1088/0967-3334/24/2/307
– volume: 62
  start-page: 1927
  year: 2015
  ident: 212_CR32
  publication-title: IEEE Trans Biomed Eng
  doi: 10.1109/TBME.2015.2407491
– volume: 5
  start-page: 35
  issue: 1
  year: 2012
  ident: 212_CR41
  publication-title: Int J Emerg Med
  doi: 10.1186/1865-1380-5-35
– volume: 18
  start-page: 185
  year: 2010
  ident: 212_CR23
  publication-title: IEEE Trans Neural Syst Rehabil Eng
  doi: 10.1109/TNSRE.2009.2039619
– volume: 16
  start-page: 37
  year: 2008
  ident: 212_CR40
  publication-title: IEEE Trans Neural Syst Rehabil Eng
  doi: 10.1109/TNSRE.2007.910282
– volume: 301
  start-page: 619
  year: 2009
  ident: 212_CR7
  publication-title: JAMA-J Am Med Assoc
  doi: 10.1001/jama.2009.116
– volume: 49
  start-page: 1617
  year: 2012
  ident: 212_CR17
  publication-title: Psychophysiology
  doi: 10.1111/j.1469-8986.2012.01471.x
– volume: 192
  start-page: 152
  year: 2010
  ident: 212_CR20
  publication-title: J Neurosci Methods
  doi: 10.1016/j.jneumeth.2010.07.015
– volume: 27
  start-page: 1226
  year: 2005
  ident: 212_CR38
  publication-title: IEEE Trans Pattern Anal Mach Intell
  doi: 10.1109/TPAMI.2005.159
– volume: 56
  start-page: 1407
  year: 2009
  ident: 212_CR31
  publication-title: IEEE Trans Biomed Eng
  doi: 10.1109/TBME.2008.2008171
– volume: 32
  start-page: 132
  year: 2005
  ident: 212_CR36
  publication-title: Clin Exp Pharmacol Physiol
  doi: 10.1111/j.1440-1681.2005.04142.x
– volume: 3
  start-page: 55
  year: 2011
  ident: 212_CR1
  publication-title: Pm & R J Inj Funct Rehabil
– volume: 485
  start-page: 372
  year: 2012
  ident: 212_CR10
  publication-title: Nature
  doi: 10.1038/nature11076
– volume-title: International conference of the IEEE engineering in medicine & biology society
  year: 2015
  ident: 212_CR35
– volume: SMC-4
  start-page: 116
  year: 1974
  ident: 212_CR39
  publication-title: IEEE Trans Syst Man Cybern
  doi: 10.1109/TSMC.1974.5408535
– volume: 50
  start-page: 848
  year: 2003
  ident: 212_CR24
  publication-title: IEEE Trans Biomed Eng
  doi: 10.1109/TBME.2003.813539
– volume: 56
  start-page: 1070
  year: 2009
  ident: 212_CR3
  publication-title: IEEE Trans Biomed Eng
  doi: 10.1109/TBME.2008.2007967
– volume: 39
  start-page: 7420
  year: 2012
  ident: 212_CR28
  publication-title: Expert Syst Appl
  doi: 10.1016/j.eswa.2012.01.102
– volume: 40
  start-page: 82
  year: 1993
  ident: 212_CR26
  publication-title: IEEE Trans Biomed Eng
  doi: 10.1109/10.204774
– volume: 13
  start-page: 1
  year: 2014
  ident: 212_CR34
  publication-title: Biomed Eng Online.
  doi: 10.1186/1475-925X-13-102
– volume: 6928
  start-page: 601
  year: 2011
  ident: 212_CR15
  publication-title: Lect Notes Comput Sci
  doi: 10.1007/978-3-642-27579-1_77
– ident: 212_CR9
  doi: 10.1007/978-3-319-10978-7_1
– volume: 58
  start-page: 2867
  year: 2011
  ident: 212_CR13
  publication-title: IEEE Trans Biomed Eng
  doi: 10.1109/TBME.2011.2161671
– volume: 149
  start-page: 296
  year: 2010
  ident: 212_CR21
  publication-title: Pain
  doi: 10.1016/j.pain.2010.02.020
– volume: 22
  start-page: 501
  year: 2014
  ident: 212_CR18
  publication-title: IEEE Trans Neural Syst Rehabil Eng
  doi: 10.1109/TNSRE.2013.2278411
– volume: 134
  start-page: 9
  year: 2004
  ident: 212_CR19
  publication-title: J Neurosci Methods
  doi: 10.1016/j.jneumeth.2003.10.009
– volume: 4
  start-page: 147
  year: 2013
  ident: 212_CR14
  publication-title: Paladyn
– volume: 22
  start-page: 478
  year: 2012
  ident: 212_CR33
  publication-title: J Electromyogr Kinesiol
  doi: 10.1016/j.jelekin.2011.12.012
– volume: 22
  start-page: 797
  year: 2014
  ident: 212_CR5
  publication-title: IEEE Trans Neural Syst Rehabil Eng
  doi: 10.1109/TNSRE.2014.2305111
– volume: 9
  start-page: 74
  year: 2012
  ident: 212_CR6
  publication-title: J NeuroEng Rehabil
  doi: 10.1186/1743-0003-9-74
– volume: 30
  start-page: 1
  year: 2015
  ident: 212_CR16
  publication-title: Intell Syst IEEE
  doi: 10.1109/MIS.2015.40
– volume: 28
  start-page: 90
  year: 2016
  ident: 212_CR4
  publication-title: J Electromyogr Kinesiol
  doi: 10.1016/j.jelekin.2016.03.005
– volume: 48
  start-page: 643
  year: 2011
  ident: 212_CR8
  publication-title: J Rehabil Res Dev
  doi: 10.1682/JRRD.2010.09.0177
– volume: 119
  start-page: 1248
  year: 2008
  ident: 212_CR30
  publication-title: Clin Neurophysiol
  doi: 10.1016/j.clinph.2008.02.001
– volume: 37
  start-page: 21
  year: 2013
  ident: 212_CR37
  publication-title: Comput Graph
  doi: 10.1016/j.cag.2012.10.006
– ident: 212_CR12
  doi: 10.1002/9781118628522
– ident: 212_CR27
– volume: 135
  start-page: 582
  year: 2012
  ident: 212_CR22
  publication-title: Brain j neurol
  doi: 10.1093/brain/awr337
– volume: 11
  start-page: 1
  year: 2014
  ident: 212_CR2
  publication-title: J NeuroEng Rehabil.
  doi: 10.1186/1743-0003-11-1
– volume: 55
  start-page: 361
  year: 2008
  ident: 212_CR11
  publication-title: Biomed Eng IEEE Trans
  doi: 10.1109/TBME.2007.897815
– volume-title: Time domain feature extraction and classification of EEG data for brain computer interface
  year: 2012
  ident: 212_CR29
  doi: 10.1109/FSKD.2012.6234336
– reference: 21257135 - PM R. 2011 Jan;3(1):55-67
– reference: 22345089 - Brain. 2012 Feb;135(Pt 2):582-95
– reference: 26737014 - Conf Proc IEEE Eng Med Biol Soc. 2015 ;2015 :3367-70
– reference: 12812417 - Physiol Meas. 2003 May;24(2):309-19
– reference: 20071269 - IEEE Trans Neural Syst Rehabil Eng. 2010 Apr;18(2):185-92
– reference: 15102499 - J Neurosci Methods. 2004 Mar 15;134(1):9-21
– reference: 22269773 - J Electromyogr Kinesiol. 2012 Jun;22(3):478-84
– reference: 21938652 - J Rehabil Res Dev. 2011;48(6):643-59
– reference: 19211469 - JAMA. 2009 Feb 11;301(6):619-28
– reference: 25570515 - Conf Proc IEEE Eng Med Biol Soc. 2014;2014:2569-72
– reference: 19473932 - IEEE Trans Biomed Eng. 2009 May;56(5):1407-14
– reference: 24760934 - IEEE Trans Neural Syst Rehabil Eng. 2014 Jul;22(4):797-809
– reference: 25516421 - J Neuroeng Rehabil. 2014 Dec 17;11:168
– reference: 18232384 - IEEE Trans Biomed Eng. 2008 Jan;55(1):361-4
– reference: 23006616 - Int J Emerg Med. 2012 Sep 24;5(1):35
– reference: 23996582 - IEEE Trans Neural Syst Rehabil Eng. 2014 May;22(3):501-10
– reference: 27093136 - J Electromyogr Kinesiol. 2016 Jun;28:90-8
– reference: 15730449 - Clin Exp Pharmacol Physiol. 2005 Jan-Feb;32(1-2):132-4
– reference: 23036049 - J Neuroeng Rehabil. 2012 Oct 05;9:74
– reference: 16119262 - IEEE Trans Pattern Anal Mach Intell. 2005 Aug;27(8):1226-38
– reference: 20359825 - Pain. 2010 May;149(2):296-304
– reference: 23013047 - Psychophysiology. 2012 Nov;49(11):1617-21
– reference: 8468080 - IEEE Trans Biomed Eng. 1993 Jan;40(1):82-94
– reference: 21768042 - IEEE Trans Biomed Eng. 2011 Oct;58(10):2867-75
– reference: 20654646 - J Neurosci Methods. 2010 Sep 30;192(1):152-62
– reference: 12848352 - IEEE Trans Biomed Eng. 2003 Jul;50(7):848-54
– reference: 25060509 - Biomed Eng Online. 2014 Jul 25;13:102
– reference: 18303804 - IEEE Trans Neural Syst Rehabil Eng. 2008 Feb;16(1):37-45
– reference: 18381249 - Clin Neurophysiol. 2008 Jun;119(6):1248-61
– reference: 25730820 - IEEE Trans Biomed Eng. 2015 Aug;62(8):1927-36
– reference: 19272889 - IEEE Trans Biomed Eng. 2009 Apr;56(4):1070-80
– reference: 22596161 - Nature. 2012 May 16;485(7398):372-5
SSID ssj0034054
Score 2.5125759
Snippet Most of the modern motorized prostheses are controlled with the surface electromyography (sEMG) recorded on the residual muscles of amputated limbs. However,...
Background Most of the modern motorized prostheses are controlled with the surface electromyography (sEMG) recorded on the residual muscles of amputated limbs....
SourceID pubmedcentral
proquest
gale
pubmed
crossref
SourceType Open Access Repository
Aggregation Database
Index Database
Enrichment Source
StartPage 2
SubjectTerms Algorithms
Amputation
Amputees
Artificial Limbs
Discriminant Analysis
Electrodes
Electroencephalography
Electroencephalography - methods
Electromyography
Electromyography - methods
Humans
Male
Methods
Motion
Movement - physiology
Pattern Recognition, Automated - methods
Physiological aspects
Signal processing
Signal Processing, Computer-Assisted
Wrist Joint
SummonAdditionalLinks – databaseName: ProQuest Technology Collection
  dbid: 8FG
  link: http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwfV3di9QwEB_0BNEHP9av6ikR_AAhXJOmTfMki-zuIayI3MG9SEnTlDs4u-t198H7651p03Xrw_WxmZQhk_lIZvobgHfIXFmjm-JoAks6oFheijrjaeyz2ieJz7v-Kctv2fGp-nqWnoULtzaUVQ42sTPU1crRHfmRyDGWkFqn6ef1b05doyi7Glpo3IY7Aj0NlXTl88VgiRMMRlTIZOL0oxZ9W041F1R2KyS_Hvmi_y3ynksal0vu-Z_5I3gQAkc27SX9GG75ZgL39-AEJ3B3GRLlE3i_jx7MTnroAPaB_RgBc0_g4fcgp4HmCfycsr61D3cUWVMpUUfM2h7I9g8jz1cxejNbLvhstmBUBYLfwJXEg3ZPjcEw267X_opfXvwqme2aR_j2KZzOZydfjnlowsCdMmrDTSWtqI0qjbDSyNRlceVFlTib4CMsSTqXwsVJqpVyJvWq1rLE99qhwtvkGRw0q8a_AKYSq9GcOJdZAra3VqJvFHlpCII-kWkE8SCOwoWFoEYZl0V3UsmzopdgQVVpJMHiOoJPuynrHp7jJuKPJOOCVBe_62z4AwG5IxCsYqoI2SjODXJyOKJElXPj4WGXFEHl2-LfBo3g7W6YZlIZW-NXW6JJKY2NZ-YInvebasc2pbiF1iYCPdpuOwICAh-PNBfnHSA4hmAm0-LlzWy9gnuSYhK6P9KHcLC52vrXGFFtyjed2vwFo28fjw
  priority: 102
  providerName: ProQuest
Title A motion-classification strategy based on sEMG-EEG signal combination for upper-limb amputees
URI https://www.ncbi.nlm.nih.gov/pubmed/28061779
https://www.proquest.com/docview/1865027755
https://www.proquest.com/docview/1856592156
https://pubmed.ncbi.nlm.nih.gov/PMC5219671
Volume 14
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwlV3ra9swED_6gLF92CN7ZeuCBnvAQJ1tyZb9YQxvOCmBlNI1kC_DyIrMCpmb5QFr__rd-UU8ymD-EIN1VoTupLvznX4H8AYHl-WopjhugRk5KJpnbh5w37FBboWwYVk_ZXIanEzleObP9qApb1VP4PpW147qSU1Xi-Pfv64_44L_VC74MPi4Rp0VUi4FpdO6Hr_Zh0NUTIoKGkxkG1QQaJvI6nykoMPUog5y3tpFR039vVnvaKtuJuWOaho-hPu1TcniSggewZ4tenBvB2mwB3cmdQy9B293gYXZRYUqwN6x8w5mdw8enNUsbGgew_eYVVV_uCGjm7KMSmK2rjBurxkpxTmjJ8lkxJNkxChBBPtAwUYfvKJGO5ltl0u74ovLnxnTZV0Ju34C02Fy8fWE1_UZuJGR3PBo7mk3j2QWudqLPN8Ezty6c2G0wMvVJASh5xpH-EpKE_lW5srL8LkyuBdo8RQOiqvCPgcmhVa40xgTaMK819pDtemGWUTo9MLz--A07EhNPRFUQ2ORlk5MGKQVB1NKWCMOpjd9-NC-sqyQO_5F_J54nJKcYb9G14cTcHSEj5XGkkCPnDDCkRx1KHE1mm5zIyVpI8wp_qVPsXIfm1-3zfQmZbgV9mpLND5FuNGd7sOzSqjaYVP021Uq6oPqiFtLQBjh3Zbi8keJFY7WWRQo98X_TMZLuOuR8UIfmtQRHGxWW_sKTa9NNoB9NVP4Gw5HAziM4_G3Md6_JKdn54Pyc8agXHJ_AGoiLlM
linkProvider Scholars Portal
linkToHtml http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwtV1LbxMxEB6VIvE48AgUFgoYiYKEZDX2etfrA0IR5FHaVAilUi9o63UcUalsQpMItT-K38jMPkKWQ2_NcT1rjTLjeeyMvwF4g8xlE3RTHE1gRgmK5ZmYxDxq-3jiw9AnxfyU4WE8OFJfjqPjDfhT34WhtsraJhaGejx19I18VyQYS0ito-jj7BenqVFUXa1HaJRqse8vfmPKNv-w9xnluyNlrzv6NODVVAHulFELbsbSiolRmRFWGhm5uD32Yhw6G-JPWGI9kcK1w0gr5Uzk1UTLDJ9rhxpsQ9z3BtxUIXpyupne69eWP8TgR1WVU2R3d46-NKEeD2rzFZJfNnzf_x5gzQU22zPX_F3vAdyrAlXWKTXrIWz4vAV31-ALW3BrWBXmW7CzjlbMRiVUAXvLvjWAwFtw_2ulFzXNI_jeYeUoIe4okqfWpYKYzUvg3AtGnnbM6El32Ofdbp9R1wnugZLDxL6kxuCbLWczf87PTn9mzBbDKvz8MRxdi3i2YDOf5v4pMBVajebLudgSkL61En2xSDJDkPehjAJo1-JIXfVH0GCOs7TIjJI4LSWYUhccSTC9DOD96pVZCQdyFfE7knFKpgL3dba68YDcEehW2lGEpNRODHKy3aDEI-6ay7WWpJWJmaf_DkQAr1fL9Ca1zeV-uiSaiMrmmKMH8KRUqhXbVFIXWpsAdEPdVgQEPN5cyU9_FADkGPKZWItnV7P1Cm4PRsOD9GDvcP853JEUD9G3K70Nm4vzpX-B0dwie1kcIQYn131m_wJ2QVwR
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=A+motion-classification+strategy+based+on+sEMG-EEG+signal+combination+for+upper-limb+amputees&rft.jtitle=Journal+of+neuroengineering+and+rehabilitation&rft.au=Li%2C+Xiangxin&rft.au=Samuel%2C+Oluwarotimi+Williams&rft.au=Zhang%2C+Xu&rft.au=Wang%2C+Hui&rft.date=2017-01-07&rft.issn=1743-0003&rft.eissn=1743-0003&rft.volume=14&rft.issue=1&rft_id=info:doi/10.1186%2Fs12984-016-0212-z&rft.externalDBID=n%2Fa&rft.externalDocID=10_1186_s12984_016_0212_z
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1743-0003&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1743-0003&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1743-0003&client=summon