A motion-classification strategy based on sEMG-EEG signal combination for upper-limb amputees
Most of the modern motorized prostheses are controlled with the surface electromyography (sEMG) recorded on the residual muscles of amputated limbs. However, the residual muscles are usually limited, especially after above-elbow amputations, which would not provide enough sEMG for the control of pro...
Saved in:
Published in | Journal of neuroengineering and rehabilitation Vol. 14; no. 1; p. 2 |
---|---|
Main Authors | , , , , , |
Format | Journal Article |
Language | English |
Published |
England
BioMed Central Ltd
07.01.2017
BioMed Central |
Subjects | |
Online Access | Get full text |
Cover
Loading…
Abstract | Most of the modern motorized prostheses are controlled with the surface electromyography (sEMG) recorded on the residual muscles of amputated limbs. However, the residual muscles are usually limited, especially after above-elbow amputations, which would not provide enough sEMG for the control of prostheses with multiple degrees of freedom. Signal fusion is a possible approach to solve the problem of insufficient control commands, where some non-EMG signals are combined with sEMG signals to provide sufficient information for motion intension decoding. In this study, a motion-classification method that combines sEMG and electroencephalography (EEG) signals were proposed and investigated, in order to improve the control performance of upper-limb prostheses.
Four transhumeral amputees without any form of neurological disease were recruited in the experiments. Five motion classes including hand-open, hand-close, wrist-pronation, wrist-supination, and no-movement were specified. During the motion performances, sEMG and EEG signals were simultaneously acquired from the skin surface and scalp of the amputees, respectively. The two types of signals were independently preprocessed and then combined as a parallel control input. Four time-domain features were extracted and fed into a classifier trained by the Linear Discriminant Analysis (LDA) algorithm for motion recognition. In addition, channel selections were performed by using the Sequential Forward Selection (SFS) algorithm to optimize the performance of the proposed method.
The classification performance achieved by the fusion of sEMG and EEG signals was significantly better than that obtained by single signal source of either sEMG or EEG. An increment of more than 14% in classification accuracy was achieved when using a combination of 32-channel sEMG and 64-channel EEG. Furthermore, based on the SFS algorithm, two optimized electrode arrangements (10-channel sEMG + 10-channel EEG, 10-channel sEMG + 20-channel EEG) were obtained with classification accuracies of 84.2 and 87.0%, respectively, which were about 7.2 and 10% higher than the accuracy by using only 32-channel sEMG input.
This study demonstrated the feasibility of fusing sEMG and EEG signals towards improving motion classification accuracy for above-elbow amputees, which might enhance the control performances of multifunctional myoelectric prostheses in clinical application.
The study was approved by the ethics committee of Institutional Review Board of Shenzhen Institutes of Advanced Technology, and the reference number is SIAT-IRB-150515-H0077. |
---|---|
AbstractList | Most of the modern motorized prostheses are controlled with the surface electromyography (sEMG) recorded on the residual muscles of amputated limbs. However, the residual muscles are usually limited, especially after above-elbow amputations, which would not provide enough sEMG for the control of prostheses with multiple degrees of freedom. Signal fusion is a possible approach to solve the problem of insufficient control commands, where some non-EMG signals are combined with sEMG signals to provide sufficient information for motion intension decoding. In this study, a motion-classification method that combines sEMG and electroencephalography (EEG) signals were proposed and investigated, in order to improve the control performance of upper-limb prostheses.BACKGROUNDMost of the modern motorized prostheses are controlled with the surface electromyography (sEMG) recorded on the residual muscles of amputated limbs. However, the residual muscles are usually limited, especially after above-elbow amputations, which would not provide enough sEMG for the control of prostheses with multiple degrees of freedom. Signal fusion is a possible approach to solve the problem of insufficient control commands, where some non-EMG signals are combined with sEMG signals to provide sufficient information for motion intension decoding. In this study, a motion-classification method that combines sEMG and electroencephalography (EEG) signals were proposed and investigated, in order to improve the control performance of upper-limb prostheses.Four transhumeral amputees without any form of neurological disease were recruited in the experiments. Five motion classes including hand-open, hand-close, wrist-pronation, wrist-supination, and no-movement were specified. During the motion performances, sEMG and EEG signals were simultaneously acquired from the skin surface and scalp of the amputees, respectively. The two types of signals were independently preprocessed and then combined as a parallel control input. Four time-domain features were extracted and fed into a classifier trained by the Linear Discriminant Analysis (LDA) algorithm for motion recognition. In addition, channel selections were performed by using the Sequential Forward Selection (SFS) algorithm to optimize the performance of the proposed method.METHODSFour transhumeral amputees without any form of neurological disease were recruited in the experiments. Five motion classes including hand-open, hand-close, wrist-pronation, wrist-supination, and no-movement were specified. During the motion performances, sEMG and EEG signals were simultaneously acquired from the skin surface and scalp of the amputees, respectively. The two types of signals were independently preprocessed and then combined as a parallel control input. Four time-domain features were extracted and fed into a classifier trained by the Linear Discriminant Analysis (LDA) algorithm for motion recognition. In addition, channel selections were performed by using the Sequential Forward Selection (SFS) algorithm to optimize the performance of the proposed method.The classification performance achieved by the fusion of sEMG and EEG signals was significantly better than that obtained by single signal source of either sEMG or EEG. An increment of more than 14% in classification accuracy was achieved when using a combination of 32-channel sEMG and 64-channel EEG. Furthermore, based on the SFS algorithm, two optimized electrode arrangements (10-channel sEMG + 10-channel EEG, 10-channel sEMG + 20-channel EEG) were obtained with classification accuracies of 84.2 and 87.0%, respectively, which were about 7.2 and 10% higher than the accuracy by using only 32-channel sEMG input.RESULTSThe classification performance achieved by the fusion of sEMG and EEG signals was significantly better than that obtained by single signal source of either sEMG or EEG. An increment of more than 14% in classification accuracy was achieved when using a combination of 32-channel sEMG and 64-channel EEG. Furthermore, based on the SFS algorithm, two optimized electrode arrangements (10-channel sEMG + 10-channel EEG, 10-channel sEMG + 20-channel EEG) were obtained with classification accuracies of 84.2 and 87.0%, respectively, which were about 7.2 and 10% higher than the accuracy by using only 32-channel sEMG input.This study demonstrated the feasibility of fusing sEMG and EEG signals towards improving motion classification accuracy for above-elbow amputees, which might enhance the control performances of multifunctional myoelectric prostheses in clinical application.CONCLUSIONSThis study demonstrated the feasibility of fusing sEMG and EEG signals towards improving motion classification accuracy for above-elbow amputees, which might enhance the control performances of multifunctional myoelectric prostheses in clinical application.The study was approved by the ethics committee of Institutional Review Board of Shenzhen Institutes of Advanced Technology, and the reference number is SIAT-IRB-150515-H0077.TRIAL REGISTRATIONThe study was approved by the ethics committee of Institutional Review Board of Shenzhen Institutes of Advanced Technology, and the reference number is SIAT-IRB-150515-H0077. Most of the modern motorized prostheses are controlled with the surface electromyography (sEMG) recorded on the residual muscles of amputated limbs. However, the residual muscles are usually limited, especially after above-elbow amputations, which would not provide enough sEMG for the control of prostheses with multiple degrees of freedom. Signal fusion is a possible approach to solve the problem of insufficient control commands, where some non-EMG signals are combined with sEMG signals to provide sufficient information for motion intension decoding. In this study, a motion-classification method that combines sEMG and electroencephalography (EEG) signals were proposed and investigated, in order to improve the control performance of upper-limb prostheses. Four transhumeral amputees without any form of neurological disease were recruited in the experiments. Five motion classes including hand-open, hand-close, wrist-pronation, wrist-supination, and no-movement were specified. During the motion performances, sEMG and EEG signals were simultaneously acquired from the skin surface and scalp of the amputees, respectively. The two types of signals were independently preprocessed and then combined as a parallel control input. Four time-domain features were extracted and fed into a classifier trained by the Linear Discriminant Analysis (LDA) algorithm for motion recognition. In addition, channel selections were performed by using the Sequential Forward Selection (SFS) algorithm to optimize the performance of the proposed method. The classification performance achieved by the fusion of sEMG and EEG signals was significantly better than that obtained by single signal source of either sEMG or EEG. An increment of more than 14% in classification accuracy was achieved when using a combination of 32-channel sEMG and 64-channel EEG. Furthermore, based on the SFS algorithm, two optimized electrode arrangements (10-channel sEMG + 10-channel EEG, 10-channel sEMG + 20-channel EEG) were obtained with classification accuracies of 84.2 and 87.0%, respectively, which were about 7.2 and 10% higher than the accuracy by using only 32-channel sEMG input. This study demonstrated the feasibility of fusing sEMG and EEG signals towards improving motion classification accuracy for above-elbow amputees, which might enhance the control performances of multifunctional myoelectric prostheses in clinical application. Background Most of the modern motorized prostheses are controlled with the surface electromyography (sEMG) recorded on the residual muscles of amputated limbs. However, the residual muscles are usually limited, especially after above-elbow amputations, which would not provide enough sEMG for the control of prostheses with multiple degrees of freedom. Signal fusion is a possible approach to solve the problem of insufficient control commands, where some non-EMG signals are combined with sEMG signals to provide sufficient information for motion intension decoding. In this study, a motion-classification method that combines sEMG and electroencephalography (EEG) signals were proposed and investigated, in order to improve the control performance of upper-limb prostheses. Methods Four transhumeral amputees without any form of neurological disease were recruited in the experiments. Five motion classes including hand-open, hand-close, wrist-pronation, wrist-supination, and no-movement were specified. During the motion performances, sEMG and EEG signals were simultaneously acquired from the skin surface and scalp of the amputees, respectively. The two types of signals were independently preprocessed and then combined as a parallel control input. Four time-domain features were extracted and fed into a classifier trained by the Linear Discriminant Analysis (LDA) algorithm for motion recognition. In addition, channel selections were performed by using the Sequential Forward Selection (SFS) algorithm to optimize the performance of the proposed method. Results The classification performance achieved by the fusion of sEMG and EEG signals was significantly better than that obtained by single signal source of either sEMG or EEG. An increment of more than 14% in classification accuracy was achieved when using a combination of 32-channel sEMG and 64-channel EEG. Furthermore, based on the SFS algorithm, two optimized electrode arrangements (10-channel sEMG + 10-channel EEG, 10-channel sEMG + 20-channel EEG) were obtained with classification accuracies of 84.2 and 87.0%, respectively, which were about 7.2 and 10% higher than the accuracy by using only 32-channel sEMG input. Conclusions This study demonstrated the feasibility of fusing sEMG and EEG signals towards improving motion classification accuracy for above-elbow amputees, which might enhance the control performances of multifunctional myoelectric prostheses in clinical application. Trial registration The study was approved by the ethics committee of Institutional Review Board of Shenzhen Institutes of Advanced Technology, and the reference number is SIAT-IRB-150515-H0077. Keywords: Amputee, EEG, Hybrid interface, Motion classification, Multifunctional prosthesis, Pattern recognition, Rehabilitation, sEMG, Signal Fusion Most of the modern motorized prostheses are controlled with the surface electromyography (sEMG) recorded on the residual muscles of amputated limbs. However, the residual muscles are usually limited, especially after above-elbow amputations, which would not provide enough sEMG for the control of prostheses with multiple degrees of freedom. Signal fusion is a possible approach to solve the problem of insufficient control commands, where some non-EMG signals are combined with sEMG signals to provide sufficient information for motion intension decoding. In this study, a motion-classification method that combines sEMG and electroencephalography (EEG) signals were proposed and investigated, in order to improve the control performance of upper-limb prostheses. Four transhumeral amputees without any form of neurological disease were recruited in the experiments. Five motion classes including hand-open, hand-close, wrist-pronation, wrist-supination, and no-movement were specified. During the motion performances, sEMG and EEG signals were simultaneously acquired from the skin surface and scalp of the amputees, respectively. The two types of signals were independently preprocessed and then combined as a parallel control input. Four time-domain features were extracted and fed into a classifier trained by the Linear Discriminant Analysis (LDA) algorithm for motion recognition. In addition, channel selections were performed by using the Sequential Forward Selection (SFS) algorithm to optimize the performance of the proposed method. The classification performance achieved by the fusion of sEMG and EEG signals was significantly better than that obtained by single signal source of either sEMG or EEG. An increment of more than 14% in classification accuracy was achieved when using a combination of 32-channel sEMG and 64-channel EEG. Furthermore, based on the SFS algorithm, two optimized electrode arrangements (10-channel sEMG + 10-channel EEG, 10-channel sEMG + 20-channel EEG) were obtained with classification accuracies of 84.2 and 87.0%, respectively, which were about 7.2 and 10% higher than the accuracy by using only 32-channel sEMG input. This study demonstrated the feasibility of fusing sEMG and EEG signals towards improving motion classification accuracy for above-elbow amputees, which might enhance the control performances of multifunctional myoelectric prostheses in clinical application. The study was approved by the ethics committee of Institutional Review Board of Shenzhen Institutes of Advanced Technology, and the reference number is SIAT-IRB-150515-H0077. Background Most of the modern motorized prostheses are controlled with the surface electromyography (sEMG) recorded on the residual muscles of amputated limbs. However, the residual muscles are usually limited, especially after above-elbow amputations, which would not provide enough sEMG for the control of prostheses with multiple degrees of freedom. Signal fusion is a possible approach to solve the problem of insufficient control commands, where some non-EMG signals are combined with sEMG signals to provide sufficient information for motion intension decoding. In this study, a motion-classification method that combines sEMG and electroencephalography (EEG) signals were proposed and investigated, in order to improve the control performance of upper-limb prostheses. Methods Four transhumeral amputees without any form of neurological disease were recruited in the experiments. Five motion classes including hand-open, hand-close, wrist-pronation, wrist-supination, and no-movement were specified. During the motion performances, sEMG and EEG signals were simultaneously acquired from the skin surface and scalp of the amputees, respectively. The two types of signals were independently preprocessed and then combined as a parallel control input. Four time-domain features were extracted and fed into a classifier trained by the Linear Discriminant Analysis (LDA) algorithm for motion recognition. In addition, channel selections were performed by using the Sequential Forward Selection (SFS) algorithm to optimize the performance of the proposed method. Results The classification performance achieved by the fusion of sEMG and EEG signals was significantly better than that obtained by single signal source of either sEMG or EEG. An increment of more than 14% in classification accuracy was achieved when using a combination of 32-channel sEMG and 64-channel EEG. Furthermore, based on the SFS algorithm, two optimized electrode arrangements (10-channel sEMG + 10-channel EEG, 10-channel sEMG + 20-channel EEG) were obtained with classification accuracies of 84.2 and 87.0%, respectively, which were about 7.2 and 10% higher than the accuracy by using only 32-channel sEMG input. Conclusions This study demonstrated the feasibility of fusing sEMG and EEG signals towards improving motion classification accuracy for above-elbow amputees, which might enhance the control performances of multifunctional myoelectric prostheses in clinical application. |
ArticleNumber | 2 |
Audience | Academic |
Author | Samuel, Oluwarotimi Williams Fang, Peng Wang, Hui Li, Guanglin Li, Xiangxin Zhang, Xu |
Author_xml | – sequence: 1 givenname: Xiangxin surname: Li fullname: Li, Xiangxin – sequence: 2 givenname: Oluwarotimi Williams surname: Samuel fullname: Samuel, Oluwarotimi Williams – sequence: 3 givenname: Xu surname: Zhang fullname: Zhang, Xu – sequence: 4 givenname: Hui surname: Wang fullname: Wang, Hui – sequence: 5 givenname: Peng surname: Fang fullname: Fang, Peng – sequence: 6 givenname: Guanglin surname: Li fullname: Li, Guanglin |
BackLink | https://www.ncbi.nlm.nih.gov/pubmed/28061779$$D View this record in MEDLINE/PubMed |
BookMark | eNp9ks9vFSEQx4mpsT_0D_BiNvHihcqwsCwXk5fm-TSp8aJHQ1gWnjTsssKuSfvXy_pqbRsjHBiGzwwD8z1FR2McLUIvgZwDtM3bDFS2DBNoMKFA8c0TdAKC1ZgQUh_ds4_Rac5XxWCEs2fomLakASHkCfq2qYY4-zhiE3TO3nmj122V56Rnu7-uOp1tX62e7acd3m53Vfb7UYfKxKHz44F2MVXLNNmEgx-6Sg_TMlubn6OnTodsX9yuZ-jr--2Xiw_48vPu48XmEhsm2YxlTzU4yToJmkrKTUN6C31tdF0G6M5x3lIwpOaCMSO5ZU7QrviFIRx0fYbeHfJOSzfY3tixVB_UlPyg07WK2quHJ6P_rvbxp-IUZCOgJHhzmyDFH4vNsxp8NjYEPdq4ZAUtb7ikwJuCvn6EXsUllQ9ZqYYTKgTnf6m9Dlb50cVyr1mTqg0TjWCklSt1_g-qzN4O3pRmO1_8DwJe3X_o3Qv_NLQAcABMijkn6-4QIGoVjTqIRhXRqFU06qbEiEcxxs-_-1qq8eE_kb8AMLjFMg |
CitedBy_id | crossref_primary_10_1016_j_irbm_2024_100866 crossref_primary_10_3390_s23125575 crossref_primary_10_1016_j_bspc_2023_105249 crossref_primary_10_3389_fnins_2022_796290 crossref_primary_10_3389_fnbot_2017_00051 crossref_primary_10_3390_s21041504 crossref_primary_10_1186_s12938_019_0677_7 crossref_primary_10_1109_JBHI_2018_2864335 crossref_primary_10_3390_s17071552 crossref_primary_10_1016_j_medntd_2022_100165 crossref_primary_10_1155_2018_8948145 crossref_primary_10_1109_JSEN_2023_3255408 crossref_primary_10_1109_MSP_2021_3057042 crossref_primary_10_1002_acs_3414 crossref_primary_10_1109_ACCESS_2020_2983182 crossref_primary_10_1109_TCDS_2022_3167042 crossref_primary_10_3389_fbioe_2019_00331 crossref_primary_10_3390_app122211475 crossref_primary_10_3390_bioengineering9110634 crossref_primary_10_1016_j_cmpb_2019_04_023 crossref_primary_10_3390_bioengineering10030319 crossref_primary_10_1080_21681163_2023_2250872 crossref_primary_10_1007_s12652_021_03351_1 crossref_primary_10_3389_fnins_2021_783539 crossref_primary_10_1109_TCYB_2021_3122969 crossref_primary_10_1088_1741_2552_ac0586 crossref_primary_10_3390_s22093424 crossref_primary_10_1186_s12984_024_01345_6 crossref_primary_10_3390_s22020680 crossref_primary_10_1109_JSEN_2022_3221417 crossref_primary_10_1016_j_bspc_2022_103754 crossref_primary_10_3390_s19224931 crossref_primary_10_3390_neurosci4030018 crossref_primary_10_1109_JSEN_2024_3471894 crossref_primary_10_3390_s24010070 crossref_primary_10_1186_s12984_019_0610_0 crossref_primary_10_1142_S0219843619410068 crossref_primary_10_1088_1741_2552_aae9d4 crossref_primary_10_1109_JSEN_2020_3037061 crossref_primary_10_1016_j_mseb_2023_117119 crossref_primary_10_3389_fnins_2022_796711 crossref_primary_10_1038_s41598_018_34785_x crossref_primary_10_3390_electronics8111244 crossref_primary_10_3233_JIFS_179558 crossref_primary_10_1109_ACCESS_2019_2956018 crossref_primary_10_1093_nsr_nwad048 crossref_primary_10_1109_TNSRE_2022_3228514 crossref_primary_10_1109_JSEN_2020_3033256 crossref_primary_10_1109_ACCESS_2022_3158667 crossref_primary_10_1515_bmt_2020_0343 crossref_primary_10_3389_fnins_2025_1532099 crossref_primary_10_1080_2326263X_2022_2029308 crossref_primary_10_1109_ACCESS_2020_3012741 crossref_primary_10_1109_ACCESS_2019_2945059 crossref_primary_10_1109_JBHI_2020_3002329 crossref_primary_10_1016_j_cmpb_2019_105278 crossref_primary_10_1088_1741_2552_abca14 crossref_primary_10_1186_s12911_022_01808_7 crossref_primary_10_1049_cit2_12039 crossref_primary_10_1016_j_bspc_2021_102969 crossref_primary_10_1186_s13634_022_00939_3 crossref_primary_10_3390_s17071597 crossref_primary_10_1007_s00521_020_05536_9 crossref_primary_10_1016_j_sciaf_2023_e01945 crossref_primary_10_1109_JBHI_2022_3159792 crossref_primary_10_1109_ACCESS_2019_2891350 crossref_primary_10_3389_fnins_2021_621885 crossref_primary_10_1002_adfm_202200457 crossref_primary_10_1109_ACCESS_2024_3386554 crossref_primary_10_1109_JSEN_2020_3028697 crossref_primary_10_3390_s24155043 crossref_primary_10_1016_j_biomaterials_2024_122632 crossref_primary_10_1109_JSEN_2022_3169492 crossref_primary_10_1016_j_bbe_2019_07_007 crossref_primary_10_1049_csy2_12009 crossref_primary_10_1109_TNSRE_2020_2981659 crossref_primary_10_1016_j_compeleceng_2025_110094 crossref_primary_10_1155_2017_5090454 crossref_primary_10_1109_JSEN_2021_3119074 crossref_primary_10_3389_fnbot_2020_582728 crossref_primary_10_3390_s22030726 crossref_primary_10_1093_gigascience_giaa098 crossref_primary_10_3389_fnbot_2021_692183 crossref_primary_10_1088_2516_1091_acc625 crossref_primary_10_1007_s11370_017_0239_4 crossref_primary_10_1016_j_bspc_2022_103679 crossref_primary_10_1109_ACCESS_2021_3099973 crossref_primary_10_3389_fneur_2020_560363 crossref_primary_10_1007_s40747_020_00140_9 crossref_primary_10_3389_fnbot_2023_1161187 crossref_primary_10_34133_2021_4675326 crossref_primary_10_3389_fnins_2023_1129049 crossref_primary_10_1007_s10916_019_1364_8 crossref_primary_10_1016_j_bspc_2021_103153 crossref_primary_10_1371_journal_pone_0276921 crossref_primary_10_3389_fnbot_2021_642607 crossref_primary_10_1016_j_bspc_2020_101990 crossref_primary_10_1109_TNSRE_2024_3431025 crossref_primary_10_3389_fnbot_2019_00037 crossref_primary_10_3389_fbioe_2023_1238210 crossref_primary_10_1016_j_heliyon_2023_e18308 crossref_primary_10_1109_JSEN_2022_3220930 crossref_primary_10_3233_NRE_172394 |
Cites_doi | 10.1088/0967-3334/24/2/307 10.1109/TBME.2015.2407491 10.1186/1865-1380-5-35 10.1109/TNSRE.2009.2039619 10.1109/TNSRE.2007.910282 10.1001/jama.2009.116 10.1111/j.1469-8986.2012.01471.x 10.1016/j.jneumeth.2010.07.015 10.1109/TPAMI.2005.159 10.1109/TBME.2008.2008171 10.1111/j.1440-1681.2005.04142.x 10.1038/nature11076 10.1109/TSMC.1974.5408535 10.1109/TBME.2003.813539 10.1109/TBME.2008.2007967 10.1016/j.eswa.2012.01.102 10.1109/10.204774 10.1186/1475-925X-13-102 10.1007/978-3-642-27579-1_77 10.1007/978-3-319-10978-7_1 10.1109/TBME.2011.2161671 10.1016/j.pain.2010.02.020 10.1109/TNSRE.2013.2278411 10.1016/j.jneumeth.2003.10.009 10.1016/j.jelekin.2011.12.012 10.1109/TNSRE.2014.2305111 10.1186/1743-0003-9-74 10.1109/MIS.2015.40 10.1016/j.jelekin.2016.03.005 10.1682/JRRD.2010.09.0177 10.1016/j.clinph.2008.02.001 10.1016/j.cag.2012.10.006 10.1002/9781118628522 10.1093/brain/awr337 10.1186/1743-0003-11-1 10.1109/TBME.2007.897815 10.1109/FSKD.2012.6234336 |
ContentType | Journal Article |
Copyright | COPYRIGHT 2017 BioMed Central Ltd. Copyright BioMed Central 2017 The Author(s). 2017 |
Copyright_xml | – notice: COPYRIGHT 2017 BioMed Central Ltd. – notice: Copyright BioMed Central 2017 – notice: The Author(s). 2017 |
DBID | AAYXX CITATION CGR CUY CVF ECM EIF NPM 3V. 7QO 7RV 7TB 7TK 7TS 7X7 7XB 88C 88E 8FD 8FE 8FG 8FH 8FI 8FJ 8FK ABJCF ABUWG AFKRA AZQEC BBNVY BENPR BGLVJ BHPHI CCPQU DWQXO FR3 FYUFA GHDGH GNUQQ HCIFZ K9. KB0 L6V LK8 M0S M0T M1P M7P M7S NAPCQ P64 PHGZM PHGZT PIMPY PJZUB PKEHL PPXIY PQEST PQGLB PQQKQ PQUKI PRINS PTHSS 7X8 5PM |
DOI | 10.1186/s12984-016-0212-z |
DatabaseName | CrossRef Medline MEDLINE MEDLINE (Ovid) MEDLINE MEDLINE PubMed ProQuest Central (Corporate) Biotechnology Research Abstracts Nursing & Allied Health Database Mechanical & Transportation Engineering Abstracts Neurosciences Abstracts Physical Education Index Health & Medical Collection ProQuest Central (purchase pre-March 2016) Healthcare Administration Database (Alumni) Medical Database (Alumni Edition) Technology Research Database ProQuest SciTech Collection ProQuest Technology Collection ProQuest Natural Science Collection Hospital Premium Collection Hospital Premium Collection (Alumni Edition) ProQuest Central (Alumni) (purchase pre-March 2016) Materials Science & Engineering Collection ProQuest Central (Alumni) ProQuest Central UK/Ireland ProQuest Central Essentials Biological Science Collection ProQuest Central Technology Collection Natural Science Collection ProQuest One ProQuest Central Engineering Research Database Health Research Premium Collection (ProQuest) Health Research Premium Collection (Alumni) ProQuest Central Student SciTech Premium Collection ProQuest Health & Medical Complete (Alumni) Nursing & Allied Health Database (Alumni Edition) ProQuest Engineering Collection Biological Sciences ProQuest Health & Medical Collection Healthcare Administration Database PML(ProQuest Medical Library) Biological Science Database Engineering Database Nursing & Allied Health Premium Biotechnology and BioEngineering Abstracts ProQuest Central Premium ProQuest One Academic (New) Publicly Available Content Database ProQuest Health & Medical Research Collection ProQuest One Academic Middle East (New) ProQuest One Health & Nursing ProQuest One Academic Eastern Edition (DO NOT USE) ProQuest One Applied & Life Sciences ProQuest One Academic ProQuest One Academic UKI Edition ProQuest Central China Engineering collection MEDLINE - Academic PubMed Central (Full Participant titles) |
DatabaseTitle | CrossRef MEDLINE Medline Complete MEDLINE with Full Text PubMed MEDLINE (Ovid) Publicly Available Content Database ProQuest Central Student ProQuest Central Essentials SciTech Premium Collection ProQuest Central China ProQuest One Applied & Life Sciences Health Research Premium Collection Natural Science Collection Health & Medical Research Collection Biological Science Collection ProQuest Central (New) ProQuest Medical Library (Alumni) Engineering Collection Engineering Database ProQuest Biological Science Collection ProQuest One Academic Eastern Edition ProQuest Hospital Collection ProQuest Technology Collection Health Research Premium Collection (Alumni) Biological Science Database Neurosciences Abstracts ProQuest Hospital Collection (Alumni) Biotechnology and BioEngineering Abstracts Nursing & Allied Health Premium ProQuest Health & Medical Complete ProQuest One Academic UKI Edition ProQuest Health Management (Alumni Edition) ProQuest Nursing & Allied Health Source (Alumni) Engineering Research Database ProQuest One Academic ProQuest One Academic (New) Technology Collection Technology Research Database ProQuest One Academic Middle East (New) Mechanical & Transportation Engineering Abstracts ProQuest Health & Medical Complete (Alumni) ProQuest Central (Alumni Edition) ProQuest One Community College ProQuest One Health & Nursing ProQuest Natural Science Collection Physical Education Index ProQuest Central ProQuest Health & Medical Research Collection ProQuest Engineering Collection Biotechnology Research Abstracts Health and Medicine Complete (Alumni Edition) ProQuest Central Korea ProQuest Health Management ProQuest Nursing & Allied Health Source ProQuest SciTech Collection ProQuest Medical Library Materials Science & Engineering Collection ProQuest Central (Alumni) MEDLINE - Academic |
DatabaseTitleList | MEDLINE - Academic MEDLINE Publicly Available Content Database |
Database_xml | – sequence: 1 dbid: NPM name: PubMed url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed sourceTypes: Index Database – sequence: 2 dbid: EIF name: MEDLINE url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search sourceTypes: Index Database – sequence: 3 dbid: 8FG name: ProQuest Technology Collection url: https://search.proquest.com/technologycollection1 sourceTypes: Aggregation Database |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Medicine Engineering Occupational Therapy & Rehabilitation Physical Therapy |
EISSN | 1743-0003 |
ExternalDocumentID | PMC5219671 4312148271 A476740895 28061779 10_1186_s12984_016_0212_z |
Genre | Journal Article |
GrantInformation_xml | – fundername: ; grantid: 51275101 – fundername: ; grantid: 2014A050503052 – fundername: ; grantid: 2013CB329505 – fundername: ; grantid: 2014A030306029 – fundername: ; grantid: 2015TQ01C399 – fundername: ; grantid: 61135004 – fundername: ; grantid: 61203209 – fundername: ; grantid: 91420301 – fundername: ; grantid: KQCX2015033117354152 |
GroupedDBID | --- 0R~ 29L 2QV 2WC 53G 5GY 5VS 7RV 7X7 88E 8FE 8FG 8FH 8FI 8FJ AAFWJ AAJSJ AASML AAWTL AAYXX ABDBF ABJCF ABUWG ACGFO ACGFS ACIWK ACPRK ACUHS ADBBV ADRAZ ADUKV AENEX AFKRA AFPKN AFRAH AHBYD AHMBA AHSBF AHYZX ALIPV ALMA_UNASSIGNED_HOLDINGS AMKLP AMTXH AOIJS AQUVI BAPOH BAWUL BBNVY BCNDV BENPR BFQNJ BGLVJ BHPHI BMC BPHCQ BVXVI C6C CCPQU CITATION CS3 DIK DU5 E3Z EBD EBLON EBS EJD ESX F5P FYUFA GROUPED_DOAJ GX1 H13 HCIFZ HMCUK HYE I-F IAO IHR INH INR IPY ITC KQ8 L6V LK8 M0T M1P M48 M7P M7S ML0 M~E NAPCQ O5R O5S OK1 OVT P2P PGMZT PHGZM PHGZT PIMPY PQQKQ PROAC PSQYO PTHSS RBZ RNS ROL RPM RSV SBL SOJ TR2 TUS UKHRP WOQ WOW XSB ~8M -A0 3V. ACRMQ ADINQ C24 CGR CUY CVF ECM EIF NPM PMFND 7QO 7TB 7TK 7TS 7XB 8FD 8FK AZQEC DWQXO FR3 GNUQQ K9. P64 PJZUB PKEHL PPXIY PQEST PQGLB PQUKI PRINS 7X8 5PM |
ID | FETCH-LOGICAL-c494t-9d2a1f94b91a2925c60de1d3ca33331abf55821c035744c95e4f72babf7c051a3 |
IEDL.DBID | M48 |
ISSN | 1743-0003 |
IngestDate | Thu Aug 21 18:23:52 EDT 2025 Fri Jul 11 04:35:22 EDT 2025 Fri Jul 25 19:10:33 EDT 2025 Tue Jun 17 21:36:41 EDT 2025 Tue Jun 10 20:25:24 EDT 2025 Thu Jan 02 22:25:09 EST 2025 Thu Apr 24 23:05:26 EDT 2025 Tue Jul 01 02:19:55 EDT 2025 |
IsDoiOpenAccess | true |
IsOpenAccess | true |
IsPeerReviewed | true |
IsScholarly | true |
Issue | 1 |
Keywords | Multifunctional prosthesis Motion classification Hybrid interface Signal Fusion Amputee EEG sEMG Pattern recognition Rehabilitation |
Language | English |
License | Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
LinkModel | DirectLink |
MergedId | FETCHMERGED-LOGICAL-c494t-9d2a1f94b91a2925c60de1d3ca33331abf55821c035744c95e4f72babf7c051a3 |
Notes | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 14 content type line 23 |
OpenAccessLink | http://journals.scholarsportal.info/openUrl.xqy?doi=10.1186/s12984-016-0212-z |
PMID | 28061779 |
PQID | 1865027755 |
PQPubID | 55356 |
ParticipantIDs | pubmedcentral_primary_oai_pubmedcentral_nih_gov_5219671 proquest_miscellaneous_1856592156 proquest_journals_1865027755 gale_infotracmisc_A476740895 gale_infotracacademiconefile_A476740895 pubmed_primary_28061779 crossref_primary_10_1186_s12984_016_0212_z crossref_citationtrail_10_1186_s12984_016_0212_z |
ProviderPackageCode | CITATION AAYXX |
PublicationCentury | 2000 |
PublicationDate | 2017-01-07 |
PublicationDateYYYYMMDD | 2017-01-07 |
PublicationDate_xml | – month: 01 year: 2017 text: 2017-01-07 day: 07 |
PublicationDecade | 2010 |
PublicationPlace | England |
PublicationPlace_xml | – name: England – name: London |
PublicationTitle | Journal of neuroengineering and rehabilitation |
PublicationTitleAlternate | J Neuroeng Rehabil |
PublicationYear | 2017 |
Publisher | BioMed Central Ltd BioMed Central |
Publisher_xml | – name: BioMed Central Ltd – name: BioMed Central |
References | E Raffin (212_CR22) 2012; 135 H Daley (212_CR33) 2012; 22 H Nolan (212_CR20) 2010; 192 X Li (212_CR4) 2016; 28 D Farina (212_CR5) 2014; 22 212_CR12 H Huang (212_CR40) 2008; 16 A Delorme (212_CR19) 2004; 134 K Englehart (212_CR24) 2003; 50 L Pan (212_CR32) 2015; 62 S Debener (212_CR17) 2012; 49 Y Geng (212_CR34) 2014; 13 P Fang (212_CR16) 2015; 30 A Phinyomark (212_CR28) 2012; 39 J Lobo-Prat (212_CR2) 2014; 11 N Jiang (212_CR3) 2009; 56 S Herrmann (212_CR15) 2011; 6928 B Hudgins (212_CR26) 1993; 40 AE Schultz (212_CR1) 2011; 3 Y Geng (212_CR6) 2012; 9 M Diers (212_CR21) 2010; 149 R Boostani (212_CR25) 2003; 24 212_CR27 L Liu (212_CR37) 2013; 37 P Geethanjali (212_CR29) 2012 LJ Hargrove (212_CR31) 2009; 56 A Omurtag (212_CR41) 2012; 5 H Huang (212_CR13) 2011; 58 HC Peng (212_CR38) 2005; 27 LR Hochberg (212_CR10) 2012; 485 G Li (212_CR23) 2010; 18 TM Cover (212_CR39) 1974; SMC-4 E Scheme (212_CR8) 2011; 48 A Woodhouse (212_CR36) 2005; 32 N Jiang (212_CR18) 2014; 22 BR Greene (212_CR30) 2008; 119 TD Lalitharatne (212_CR14) 2013; 4 TA Kuiken (212_CR7) 2009; 301 GR Müller-Putz (212_CR11) 2008; 55 H Wang (212_CR35) 2015 212_CR9 12812417 - Physiol Meas. 2003 May;24(2):309-19 26737014 - Conf Proc IEEE Eng Med Biol Soc. 2015 ;2015 :3367-70 25730820 - IEEE Trans Biomed Eng. 2015 Aug;62(8):1927-36 22345089 - Brain. 2012 Feb;135(Pt 2):582-95 20654646 - J Neurosci Methods. 2010 Sep 30;192(1):152-62 20071269 - IEEE Trans Neural Syst Rehabil Eng. 2010 Apr;18(2):185-92 27093136 - J Electromyogr Kinesiol. 2016 Jun;28:90-8 25060509 - Biomed Eng Online. 2014 Jul 25;13:102 20359825 - Pain. 2010 May;149(2):296-304 23036049 - J Neuroeng Rehabil. 2012 Oct 05;9:74 23006616 - Int J Emerg Med. 2012 Sep 24;5(1):35 25570515 - Conf Proc IEEE Eng Med Biol Soc. 2014;2014:2569-72 22596161 - Nature. 2012 May 16;485(7398):372-5 12848352 - IEEE Trans Biomed Eng. 2003 Jul;50(7):848-54 21938652 - J Rehabil Res Dev. 2011;48(6):643-59 23996582 - IEEE Trans Neural Syst Rehabil Eng. 2014 May;22(3):501-10 19272889 - IEEE Trans Biomed Eng. 2009 Apr;56(4):1070-80 15730449 - Clin Exp Pharmacol Physiol. 2005 Jan-Feb;32(1-2):132-4 22269773 - J Electromyogr Kinesiol. 2012 Jun;22(3):478-84 15102499 - J Neurosci Methods. 2004 Mar 15;134(1):9-21 21257135 - PM R. 2011 Jan;3(1):55-67 24760934 - IEEE Trans Neural Syst Rehabil Eng. 2014 Jul;22(4):797-809 23013047 - Psychophysiology. 2012 Nov;49(11):1617-21 25516421 - J Neuroeng Rehabil. 2014 Dec 17;11:168 21768042 - IEEE Trans Biomed Eng. 2011 Oct;58(10):2867-75 19473932 - IEEE Trans Biomed Eng. 2009 May;56(5):1407-14 18381249 - Clin Neurophysiol. 2008 Jun;119(6):1248-61 8468080 - IEEE Trans Biomed Eng. 1993 Jan;40(1):82-94 18232384 - IEEE Trans Biomed Eng. 2008 Jan;55(1):361-4 19211469 - JAMA. 2009 Feb 11;301(6):619-28 16119262 - IEEE Trans Pattern Anal Mach Intell. 2005 Aug;27(8):1226-38 18303804 - IEEE Trans Neural Syst Rehabil Eng. 2008 Feb;16(1):37-45 |
References_xml | – volume: 24 start-page: 309 year: 2003 ident: 212_CR25 publication-title: Physiol Meas doi: 10.1088/0967-3334/24/2/307 – volume: 62 start-page: 1927 year: 2015 ident: 212_CR32 publication-title: IEEE Trans Biomed Eng doi: 10.1109/TBME.2015.2407491 – volume: 5 start-page: 35 issue: 1 year: 2012 ident: 212_CR41 publication-title: Int J Emerg Med doi: 10.1186/1865-1380-5-35 – volume: 18 start-page: 185 year: 2010 ident: 212_CR23 publication-title: IEEE Trans Neural Syst Rehabil Eng doi: 10.1109/TNSRE.2009.2039619 – volume: 16 start-page: 37 year: 2008 ident: 212_CR40 publication-title: IEEE Trans Neural Syst Rehabil Eng doi: 10.1109/TNSRE.2007.910282 – volume: 301 start-page: 619 year: 2009 ident: 212_CR7 publication-title: JAMA-J Am Med Assoc doi: 10.1001/jama.2009.116 – volume: 49 start-page: 1617 year: 2012 ident: 212_CR17 publication-title: Psychophysiology doi: 10.1111/j.1469-8986.2012.01471.x – volume: 192 start-page: 152 year: 2010 ident: 212_CR20 publication-title: J Neurosci Methods doi: 10.1016/j.jneumeth.2010.07.015 – volume: 27 start-page: 1226 year: 2005 ident: 212_CR38 publication-title: IEEE Trans Pattern Anal Mach Intell doi: 10.1109/TPAMI.2005.159 – volume: 56 start-page: 1407 year: 2009 ident: 212_CR31 publication-title: IEEE Trans Biomed Eng doi: 10.1109/TBME.2008.2008171 – volume: 32 start-page: 132 year: 2005 ident: 212_CR36 publication-title: Clin Exp Pharmacol Physiol doi: 10.1111/j.1440-1681.2005.04142.x – volume: 3 start-page: 55 year: 2011 ident: 212_CR1 publication-title: Pm & R J Inj Funct Rehabil – volume: 485 start-page: 372 year: 2012 ident: 212_CR10 publication-title: Nature doi: 10.1038/nature11076 – volume-title: International conference of the IEEE engineering in medicine & biology society year: 2015 ident: 212_CR35 – volume: SMC-4 start-page: 116 year: 1974 ident: 212_CR39 publication-title: IEEE Trans Syst Man Cybern doi: 10.1109/TSMC.1974.5408535 – volume: 50 start-page: 848 year: 2003 ident: 212_CR24 publication-title: IEEE Trans Biomed Eng doi: 10.1109/TBME.2003.813539 – volume: 56 start-page: 1070 year: 2009 ident: 212_CR3 publication-title: IEEE Trans Biomed Eng doi: 10.1109/TBME.2008.2007967 – volume: 39 start-page: 7420 year: 2012 ident: 212_CR28 publication-title: Expert Syst Appl doi: 10.1016/j.eswa.2012.01.102 – volume: 40 start-page: 82 year: 1993 ident: 212_CR26 publication-title: IEEE Trans Biomed Eng doi: 10.1109/10.204774 – volume: 13 start-page: 1 year: 2014 ident: 212_CR34 publication-title: Biomed Eng Online. doi: 10.1186/1475-925X-13-102 – volume: 6928 start-page: 601 year: 2011 ident: 212_CR15 publication-title: Lect Notes Comput Sci doi: 10.1007/978-3-642-27579-1_77 – ident: 212_CR9 doi: 10.1007/978-3-319-10978-7_1 – volume: 58 start-page: 2867 year: 2011 ident: 212_CR13 publication-title: IEEE Trans Biomed Eng doi: 10.1109/TBME.2011.2161671 – volume: 149 start-page: 296 year: 2010 ident: 212_CR21 publication-title: Pain doi: 10.1016/j.pain.2010.02.020 – volume: 22 start-page: 501 year: 2014 ident: 212_CR18 publication-title: IEEE Trans Neural Syst Rehabil Eng doi: 10.1109/TNSRE.2013.2278411 – volume: 134 start-page: 9 year: 2004 ident: 212_CR19 publication-title: J Neurosci Methods doi: 10.1016/j.jneumeth.2003.10.009 – volume: 4 start-page: 147 year: 2013 ident: 212_CR14 publication-title: Paladyn – volume: 22 start-page: 478 year: 2012 ident: 212_CR33 publication-title: J Electromyogr Kinesiol doi: 10.1016/j.jelekin.2011.12.012 – volume: 22 start-page: 797 year: 2014 ident: 212_CR5 publication-title: IEEE Trans Neural Syst Rehabil Eng doi: 10.1109/TNSRE.2014.2305111 – volume: 9 start-page: 74 year: 2012 ident: 212_CR6 publication-title: J NeuroEng Rehabil doi: 10.1186/1743-0003-9-74 – volume: 30 start-page: 1 year: 2015 ident: 212_CR16 publication-title: Intell Syst IEEE doi: 10.1109/MIS.2015.40 – volume: 28 start-page: 90 year: 2016 ident: 212_CR4 publication-title: J Electromyogr Kinesiol doi: 10.1016/j.jelekin.2016.03.005 – volume: 48 start-page: 643 year: 2011 ident: 212_CR8 publication-title: J Rehabil Res Dev doi: 10.1682/JRRD.2010.09.0177 – volume: 119 start-page: 1248 year: 2008 ident: 212_CR30 publication-title: Clin Neurophysiol doi: 10.1016/j.clinph.2008.02.001 – volume: 37 start-page: 21 year: 2013 ident: 212_CR37 publication-title: Comput Graph doi: 10.1016/j.cag.2012.10.006 – ident: 212_CR12 doi: 10.1002/9781118628522 – ident: 212_CR27 – volume: 135 start-page: 582 year: 2012 ident: 212_CR22 publication-title: Brain j neurol doi: 10.1093/brain/awr337 – volume: 11 start-page: 1 year: 2014 ident: 212_CR2 publication-title: J NeuroEng Rehabil. doi: 10.1186/1743-0003-11-1 – volume: 55 start-page: 361 year: 2008 ident: 212_CR11 publication-title: Biomed Eng IEEE Trans doi: 10.1109/TBME.2007.897815 – volume-title: Time domain feature extraction and classification of EEG data for brain computer interface year: 2012 ident: 212_CR29 doi: 10.1109/FSKD.2012.6234336 – reference: 21257135 - PM R. 2011 Jan;3(1):55-67 – reference: 22345089 - Brain. 2012 Feb;135(Pt 2):582-95 – reference: 26737014 - Conf Proc IEEE Eng Med Biol Soc. 2015 ;2015 :3367-70 – reference: 12812417 - Physiol Meas. 2003 May;24(2):309-19 – reference: 20071269 - IEEE Trans Neural Syst Rehabil Eng. 2010 Apr;18(2):185-92 – reference: 15102499 - J Neurosci Methods. 2004 Mar 15;134(1):9-21 – reference: 22269773 - J Electromyogr Kinesiol. 2012 Jun;22(3):478-84 – reference: 21938652 - J Rehabil Res Dev. 2011;48(6):643-59 – reference: 19211469 - JAMA. 2009 Feb 11;301(6):619-28 – reference: 25570515 - Conf Proc IEEE Eng Med Biol Soc. 2014;2014:2569-72 – reference: 19473932 - IEEE Trans Biomed Eng. 2009 May;56(5):1407-14 – reference: 24760934 - IEEE Trans Neural Syst Rehabil Eng. 2014 Jul;22(4):797-809 – reference: 25516421 - J Neuroeng Rehabil. 2014 Dec 17;11:168 – reference: 18232384 - IEEE Trans Biomed Eng. 2008 Jan;55(1):361-4 – reference: 23006616 - Int J Emerg Med. 2012 Sep 24;5(1):35 – reference: 23996582 - IEEE Trans Neural Syst Rehabil Eng. 2014 May;22(3):501-10 – reference: 27093136 - J Electromyogr Kinesiol. 2016 Jun;28:90-8 – reference: 15730449 - Clin Exp Pharmacol Physiol. 2005 Jan-Feb;32(1-2):132-4 – reference: 23036049 - J Neuroeng Rehabil. 2012 Oct 05;9:74 – reference: 16119262 - IEEE Trans Pattern Anal Mach Intell. 2005 Aug;27(8):1226-38 – reference: 20359825 - Pain. 2010 May;149(2):296-304 – reference: 23013047 - Psychophysiology. 2012 Nov;49(11):1617-21 – reference: 8468080 - IEEE Trans Biomed Eng. 1993 Jan;40(1):82-94 – reference: 21768042 - IEEE Trans Biomed Eng. 2011 Oct;58(10):2867-75 – reference: 20654646 - J Neurosci Methods. 2010 Sep 30;192(1):152-62 – reference: 12848352 - IEEE Trans Biomed Eng. 2003 Jul;50(7):848-54 – reference: 25060509 - Biomed Eng Online. 2014 Jul 25;13:102 – reference: 18303804 - IEEE Trans Neural Syst Rehabil Eng. 2008 Feb;16(1):37-45 – reference: 18381249 - Clin Neurophysiol. 2008 Jun;119(6):1248-61 – reference: 25730820 - IEEE Trans Biomed Eng. 2015 Aug;62(8):1927-36 – reference: 19272889 - IEEE Trans Biomed Eng. 2009 Apr;56(4):1070-80 – reference: 22596161 - Nature. 2012 May 16;485(7398):372-5 |
SSID | ssj0034054 |
Score | 2.5125759 |
Snippet | Most of the modern motorized prostheses are controlled with the surface electromyography (sEMG) recorded on the residual muscles of amputated limbs. However,... Background Most of the modern motorized prostheses are controlled with the surface electromyography (sEMG) recorded on the residual muscles of amputated limbs.... |
SourceID | pubmedcentral proquest gale pubmed crossref |
SourceType | Open Access Repository Aggregation Database Index Database Enrichment Source |
StartPage | 2 |
SubjectTerms | Algorithms Amputation Amputees Artificial Limbs Discriminant Analysis Electrodes Electroencephalography Electroencephalography - methods Electromyography Electromyography - methods Humans Male Methods Motion Movement - physiology Pattern Recognition, Automated - methods Physiological aspects Signal processing Signal Processing, Computer-Assisted Wrist Joint |
SummonAdditionalLinks | – databaseName: ProQuest Technology Collection dbid: 8FG link: http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwfV3di9QwEB_0BNEHP9av6ikR_AAhXJOmTfMki-zuIayI3MG9SEnTlDs4u-t198H7651p03Xrw_WxmZQhk_lIZvobgHfIXFmjm-JoAks6oFheijrjaeyz2ieJz7v-Kctv2fGp-nqWnoULtzaUVQ42sTPU1crRHfmRyDGWkFqn6ef1b05doyi7Glpo3IY7Aj0NlXTl88VgiRMMRlTIZOL0oxZ9W041F1R2KyS_Hvmi_y3ynksal0vu-Z_5I3gQAkc27SX9GG75ZgL39-AEJ3B3GRLlE3i_jx7MTnroAPaB_RgBc0_g4fcgp4HmCfycsr61D3cUWVMpUUfM2h7I9g8jz1cxejNbLvhstmBUBYLfwJXEg3ZPjcEw267X_opfXvwqme2aR_j2KZzOZydfjnlowsCdMmrDTSWtqI0qjbDSyNRlceVFlTib4CMsSTqXwsVJqpVyJvWq1rLE99qhwtvkGRw0q8a_AKYSq9GcOJdZAra3VqJvFHlpCII-kWkE8SCOwoWFoEYZl0V3UsmzopdgQVVpJMHiOoJPuynrHp7jJuKPJOOCVBe_62z4AwG5IxCsYqoI2SjODXJyOKJElXPj4WGXFEHl2-LfBo3g7W6YZlIZW-NXW6JJKY2NZ-YInvebasc2pbiF1iYCPdpuOwICAh-PNBfnHSA4hmAm0-LlzWy9gnuSYhK6P9KHcLC52vrXGFFtyjed2vwFo28fjw priority: 102 providerName: ProQuest |
Title | A motion-classification strategy based on sEMG-EEG signal combination for upper-limb amputees |
URI | https://www.ncbi.nlm.nih.gov/pubmed/28061779 https://www.proquest.com/docview/1865027755 https://www.proquest.com/docview/1856592156 https://pubmed.ncbi.nlm.nih.gov/PMC5219671 |
Volume | 14 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwlV3ra9swED_6gLF92CN7ZeuCBnvAQJ1tyZb9YQxvOCmBlNI1kC_DyIrMCpmb5QFr__rd-UU8ymD-EIN1VoTupLvznX4H8AYHl-WopjhugRk5KJpnbh5w37FBboWwYVk_ZXIanEzleObP9qApb1VP4PpW147qSU1Xi-Pfv64_44L_VC74MPi4Rp0VUi4FpdO6Hr_Zh0NUTIoKGkxkG1QQaJvI6nykoMPUog5y3tpFR039vVnvaKtuJuWOaho-hPu1TcniSggewZ4tenBvB2mwB3cmdQy9B293gYXZRYUqwN6x8w5mdw8enNUsbGgew_eYVVV_uCGjm7KMSmK2rjBurxkpxTmjJ8lkxJNkxChBBPtAwUYfvKJGO5ltl0u74ovLnxnTZV0Ju34C02Fy8fWE1_UZuJGR3PBo7mk3j2QWudqLPN8Ezty6c2G0wMvVJASh5xpH-EpKE_lW5srL8LkyuBdo8RQOiqvCPgcmhVa40xgTaMK819pDtemGWUTo9MLz--A07EhNPRFUQ2ORlk5MGKQVB1NKWCMOpjd9-NC-sqyQO_5F_J54nJKcYb9G14cTcHSEj5XGkkCPnDDCkRx1KHE1mm5zIyVpI8wp_qVPsXIfm1-3zfQmZbgV9mpLND5FuNGd7sOzSqjaYVP021Uq6oPqiFtLQBjh3Zbi8keJFY7WWRQo98X_TMZLuOuR8UIfmtQRHGxWW_sKTa9NNoB9NVP4Gw5HAziM4_G3Md6_JKdn54Pyc8agXHJ_AGoiLlM |
linkProvider | Scholars Portal |
linkToHtml | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwtV1LbxMxEB6VIvE48AgUFgoYiYKEZDX2etfrA0IR5FHaVAilUi9o63UcUalsQpMItT-K38jMPkKWQ2_NcT1rjTLjeeyMvwF4g8xlE3RTHE1gRgmK5ZmYxDxq-3jiw9AnxfyU4WE8OFJfjqPjDfhT34WhtsraJhaGejx19I18VyQYS0ito-jj7BenqVFUXa1HaJRqse8vfmPKNv-w9xnluyNlrzv6NODVVAHulFELbsbSiolRmRFWGhm5uD32Yhw6G-JPWGI9kcK1w0gr5Uzk1UTLDJ9rhxpsQ9z3BtxUIXpyupne69eWP8TgR1WVU2R3d46-NKEeD2rzFZJfNnzf_x5gzQU22zPX_F3vAdyrAlXWKTXrIWz4vAV31-ALW3BrWBXmW7CzjlbMRiVUAXvLvjWAwFtw_2ulFzXNI_jeYeUoIe4okqfWpYKYzUvg3AtGnnbM6El32Ofdbp9R1wnugZLDxL6kxuCbLWczf87PTn9mzBbDKvz8MRxdi3i2YDOf5v4pMBVajebLudgSkL61En2xSDJDkPehjAJo1-JIXfVH0GCOs7TIjJI4LSWYUhccSTC9DOD96pVZCQdyFfE7knFKpgL3dba68YDcEehW2lGEpNRODHKy3aDEI-6ay7WWpJWJmaf_DkQAr1fL9Ca1zeV-uiSaiMrmmKMH8KRUqhXbVFIXWpsAdEPdVgQEPN5cyU9_FADkGPKZWItnV7P1Cm4PRsOD9GDvcP853JEUD9G3K70Nm4vzpX-B0dwie1kcIQYn131m_wJ2QVwR |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=A+motion-classification+strategy+based+on+sEMG-EEG+signal+combination+for+upper-limb+amputees&rft.jtitle=Journal+of+neuroengineering+and+rehabilitation&rft.au=Li%2C+Xiangxin&rft.au=Samuel%2C+Oluwarotimi+Williams&rft.au=Zhang%2C+Xu&rft.au=Wang%2C+Hui&rft.date=2017-01-07&rft.issn=1743-0003&rft.eissn=1743-0003&rft.volume=14&rft.issue=1&rft_id=info:doi/10.1186%2Fs12984-016-0212-z&rft.externalDBID=n%2Fa&rft.externalDocID=10_1186_s12984_016_0212_z |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1743-0003&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1743-0003&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1743-0003&client=summon |