A least angle regression method for fMRI activation detection in phase-encoded experimental designs

This paper presents a new regression method for functional magnetic resonance imaging (fMRI) activation detection. Unlike general linear models (GLM), this method is based on selecting models for activation detection adaptively which overcomes the limitation of requiring a predefined design matrix i...

Full description

Saved in:
Bibliographic Details
Published inNeuroImage (Orlando, Fla.) Vol. 52; no. 4; pp. 1390 - 1400
Main Authors Li, Xingfeng, Coyle, Damien, Maguire, Liam, McGinnity, Thomas M, Watson, David R, Benali, Habib
Format Journal Article
LanguageEnglish
Published United States Elsevier Inc 01.10.2010
Elsevier Limited
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:This paper presents a new regression method for functional magnetic resonance imaging (fMRI) activation detection. Unlike general linear models (GLM), this method is based on selecting models for activation detection adaptively which overcomes the limitation of requiring a predefined design matrix in GLM. This limitation is because GLM designs assume that the response of the neuron populations will be the same for the same stimuli, which is often not the case. In this work, the fMRI hemodynamic response model is selected from a series of models constructed online by the least angle regression (LARS) method. The slow drift terms in the design matrix for the activation detection are determined adaptively according to the fMRI response in order to achieve the best fit for each fMRI response. The LARS method is then applied along with the Moore–Penrose pseudoinverse (PINV) and fast orthogonal search (FOS) algorithm for implementation of the selected model to include the drift effects in the design matrix. Comparisons with GLM were made using 11 normal subjects to test method superiority. This paper found that GLM with fixed design matrix was inferior compared to the described LARS method for fMRI activation detection in a phased-encoded experimental design. In addition, the proposed method has the advantage of increasing the degrees of freedom in the regression analysis. We conclude that the method described provides a new and novel approach to the detection of fMRI activation which is better than GLM based analyses.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
ISSN:1053-8119
1095-9572
1095-9572
DOI:10.1016/j.neuroimage.2010.05.017