Consistency Between Three Different Ways of Administering the Short Form 6 Dimension Version 2

The Short Form 6 Dimension (SF-6D) is a multi-attribute utility instrument derived from the Short-Form 36 Health Survey Version 2 (SF-36v2) quality of life questionnaire and is used to calculate quality-adjusted life years (QALYs) on a scale 0 to 1. The SF-6Dv2 is a new version of the SF-6D. The aim...

Full description

Saved in:
Bibliographic Details
Published inValue in health Vol. 22; no. 7; pp. 837 - 842
Main Authors Poder, Thomas G., Fauteux, Vickie, He, Jie, Brazier, John E.
Format Journal Article
LanguageEnglish
Published United States Elsevier Inc 01.07.2019
Elsevier Science Ltd
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:The Short Form 6 Dimension (SF-6D) is a multi-attribute utility instrument derived from the Short-Form 36 Health Survey Version 2 (SF-36v2) quality of life questionnaire and is used to calculate quality-adjusted life years (QALYs) on a scale 0 to 1. The SF-6Dv2 is a new version of the SF-6D. The aim of this study was to assess the consistency of respondents’ answers to 3 different methods to administer this new version. SF-6Dv2 utility values were generated from the SF-36v2 using the following: (1) full questionnaire with 36 items (SF-6Dv2SF-36); (2) subset questionnaire with 10 items (SF-6Dv2ind-10); (3) SF-6Dv2 administered as an independent instrument (rephrased questionnaire with only 6 items [SF-6Dv2ind-6]). The order of the 3 instruments was randomly allocated between respondents. A total of 782 respondents from Quebec, Canada, were interviewed, out of whom 697 fully completed the survey. Very few deviations in respondents’ answers were observed between the 3 instruments, with mean weighted kappa of 0.79 (range 0.61-0.91) and mean global consistency index of 70% (range 54-83). Maximal difference in utility values generated was found between SF-6Dv2ind-10 and SF-6Dv2ind-6 (mean difference 0.016, P < .01), whereas minimal difference was found between SF-6Dv2SF-36 and SF-6Dv2ind-10 (0.002, P = .38). No ceiling effect was observed. The SF-6Dv2 was designed to derive utilities from the SF-36v2, and our results indicate that it is still preferable to use the full questionnaire, although the difference with other variants of the questionnaire is very small. To use the SF-6Dv2 as an independent instrument will thus introduce minimal bias in utility values generated.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
ObjectType-Article-2
ObjectType-Feature-1
content type line 23
ISSN:1098-3015
1524-4733
1524-4733
DOI:10.1016/j.jval.2018.12.012