Automated real-time analysis of intraoperative transesophageal echocardiograms

Although transesophageal echocardiography (TEE) produces real-time images depicting left ventricular (LV) filling and ejection, the quantitative analysis of these images has been too time consuming to be of practical value in the operating room. Therefore, the authors investigated whether a new auto...

Full description

Saved in:
Bibliographic Details
Published inAnesthesiology (Philadelphia) Vol. 78; no. 3; pp. 477 - 485
Main Authors CATHALAN, M. K, IONESCU, P, MELTON, H. E, ADLER, S, KEE, L. L, SCHILLER, N. B
Format Journal Article
LanguageEnglish
Published Hagerstown, MD Lippincott 01.03.1993
Subjects
Online AccessGet full text

Cover

Loading…
Abstract Although transesophageal echocardiography (TEE) produces real-time images depicting left ventricular (LV) filling and ejection, the quantitative analysis of these images has been too time consuming to be of practical value in the operating room. Therefore, the authors investigated whether a new automated border detection system (ABD) could track the endocardial border continuously and compute the cross-sectional area of the LV cavity. Using data from 25 patients who were monitored with TEE as part of their routine clinical care, the authors compared ABD estimates of LV end-diastolic area (EDA in square centimeters), end-systolic area (ESA in square centimeters), and fractional area change (FAC) with the laboratory measurements made independently by an expert. ABD slightly underestimated EDA (10.7 +/- 1.0 vs. 11.2 +/- 1.0 cm2) and slightly overestimated ESA (5.6 +/- 0.7 vs. 4.8 +/- 0.6 cm2, mean +/- standard error). However, when ABD tracking of the endocardial border was judged as "good" or "excellent" (84% of the patients at end diastole and 72% at end systole), the limits of agreement between ABD and the expert's findings were within the limits expected for two experts. By contrast, ABD significantly underestimated FAC (0.44 +/- 0.03 vs. 0.56 +/- 0.03) and the limits of agreement between ABD and the expert were more than twice as great as expected for experts, even when ABD performance was judged as "excellent." The authors conclude that, when ABD appears to be performing adequately, it underestimates LV FAC, but provides valid real-time estimates of LV EDA and ESA. Thus, it warrants further evaluation as a potentially powerful clinical and research tool.
AbstractList Although transesophageal echocardiography (TEE) produces real-time images depicting left ventricular (LV) filling and ejection, the quantitative analysis of these images has been too time consuming to be of practical value in the operating room. Therefore, the authors investigated whether a new automated border detection system (ABD) could track the endocardial border continuously and compute the cross-sectional area of the LV cavity. Using data from 25 patients who were monitored with TEE as part of their routine clinical care, the authors compared ABD estimates of LV end-diastolic area (EDA in square centimeters), end-systolic area (ESA in square centimeters), and fractional area change (FAC) with the laboratory measurements made independently by an expert. ABD slightly underestimated EDA (10.7 +/- 1.0 vs. 11.2 +/- 1.0 cm2) and slightly overestimated ESA (5.6 +/- 0.7 vs. 4.8 +/- 0.6 cm2, mean +/- standard error). However, when ABD tracking of the endocardial border was judged as "good" or "excellent" (84% of the patients at end diastole and 72% at end systole), the limits of agreement between ABD and the expert's findings were within the limits expected for two experts. By contrast, ABD significantly underestimated FAC (0.44 +/- 0.03 vs. 0.56 +/- 0.03) and the limits of agreement between ABD and the expert were more than twice as great as expected for experts, even when ABD performance was judged as "excellent." The authors conclude that, when ABD appears to be performing adequately, it underestimates LV FAC, but provides valid real-time estimates of LV EDA and ESA. Thus, it warrants further evaluation as a potentially powerful clinical and research tool.
BACKGROUNDAlthough transesophageal echocardiography (TEE) produces real-time images depicting left ventricular (LV) filling and ejection, the quantitative analysis of these images has been too time consuming to be of practical value in the operating room. Therefore, the authors investigated whether a new automated border detection system (ABD) could track the endocardial border continuously and compute the cross-sectional area of the LV cavity.METHODSUsing data from 25 patients who were monitored with TEE as part of their routine clinical care, the authors compared ABD estimates of LV end-diastolic area (EDA in square centimeters), end-systolic area (ESA in square centimeters), and fractional area change (FAC) with the laboratory measurements made independently by an expert.RESULTSABD slightly underestimated EDA (10.7 +/- 1.0 vs. 11.2 +/- 1.0 cm2) and slightly overestimated ESA (5.6 +/- 0.7 vs. 4.8 +/- 0.6 cm2, mean +/- standard error). However, when ABD tracking of the endocardial border was judged as "good" or "excellent" (84% of the patients at end diastole and 72% at end systole), the limits of agreement between ABD and the expert's findings were within the limits expected for two experts. By contrast, ABD significantly underestimated FAC (0.44 +/- 0.03 vs. 0.56 +/- 0.03) and the limits of agreement between ABD and the expert were more than twice as great as expected for experts, even when ABD performance was judged as "excellent."CONCLUSIONThe authors conclude that, when ABD appears to be performing adequately, it underestimates LV FAC, but provides valid real-time estimates of LV EDA and ESA. Thus, it warrants further evaluation as a potentially powerful clinical and research tool.
Author CATHALAN, M. K
KEE, L. L
IONESCU, P
MELTON, H. E
ADLER, S
SCHILLER, N. B
Author_xml – sequence: 1
  givenname: M. K
  surname: CATHALAN
  fullname: CATHALAN, M. K
  organization: Univ. California, dep. anesthesia, San Francisco CA 94143-0648, United States
– sequence: 2
  givenname: P
  surname: IONESCU
  fullname: IONESCU, P
  organization: Univ. California, dep. anesthesia, San Francisco CA 94143-0648, United States
– sequence: 3
  givenname: H. E
  surname: MELTON
  fullname: MELTON, H. E
  organization: Univ. California, dep. anesthesia, San Francisco CA 94143-0648, United States
– sequence: 4
  givenname: S
  surname: ADLER
  fullname: ADLER, S
  organization: Univ. California, dep. anesthesia, San Francisco CA 94143-0648, United States
– sequence: 5
  givenname: L. L
  surname: KEE
  fullname: KEE, L. L
  organization: Univ. California, dep. anesthesia, San Francisco CA 94143-0648, United States
– sequence: 6
  givenname: N. B
  surname: SCHILLER
  fullname: SCHILLER, N. B
  organization: Univ. California, dep. anesthesia, San Francisco CA 94143-0648, United States
BackLink http://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=4667674$$DView record in Pascal Francis
https://www.ncbi.nlm.nih.gov/pubmed/8457048$$D View this record in MEDLINE/PubMed
BookMark eNo9kF1LwzAUhoNM5jb9CUIvxLtq0nw1l2P4BUNv9LpkyclWaZuadML-vZnWHQiHN-d9T8IzR5POd4BQRvAdwUre42NxVuREKYppEnk6hJyhGeFFmRMi-QTN0h3NKS6KCzSP8TNJyWk5RdOScYlZOUOvy_3gWz2AzQLoJh_qFjLd6eYQ65h5l9XdELTvIeih_oYsiS5C9P1Ob5M_A7PzRgdb-23QbbxE5043Ea7GvkAfjw_vq-d8_fb0slquc8NKNuSsFKBd-jixxli64QUl2PCNspYKJZyRWBSWOaWwdaCo4QKYw5xuykIqS-kC3f7t7YP_2kMcqraOBppGd-D3sZJccMLw0Vj-GU3wMQZwVR_qVodDRXB1RFn9o6xOKKtflCl6Pb6x37RgT8GRXZrfjHMdjW5cImPqeLIxIaSQjP4AbLF-Kw
CODEN ANESAV
CitedBy_id crossref_primary_10_1016_S1280_4703_09_70443_8
crossref_primary_10_1111_j_1540_8191_1993_tb00429_x
crossref_primary_10_1016_S0749_0704_05_70284_0
crossref_primary_10_1213_ane_0b013e3181a801a3
crossref_primary_10_1177_108925329700100108
crossref_primary_10_1177_875647939401000205
crossref_primary_10_1016_S0749_0704_05_70256_6
crossref_primary_10_1016_S1053_0770_00_90004_1
crossref_primary_10_1007_s00390_004_0564_7
crossref_primary_10_1213_00000539_199612000_00003
crossref_primary_10_1053_j_jvca_2003_09_005
crossref_primary_10_1016_S0889_8537_05_70369_2
crossref_primary_10_1177_108925329700100104
crossref_primary_10_1016_S0733_8651_05_70174_0
crossref_primary_10_1016_S0894_7317_05_80006_9
crossref_primary_10_1016_S0277_0326_98_80023_8
crossref_primary_10_1016_S1053_0770_99_90090_3
crossref_primary_10_1097_00000539_199509000_00038
crossref_primary_10_1016_S0952_8180_97_00067_6
crossref_primary_10_1007_BF03014973
crossref_primary_10_1053_j_jvca_2019_09_027
crossref_primary_10_1213_00000539_199509000_00038
crossref_primary_10_1016_1053_0770_94_90192_9
crossref_primary_10_1378_chest_116_1_176
crossref_primary_10_1007_s11748_013_0208_6
crossref_primary_10_1016_S0003_4975_01_03300_8
crossref_primary_10_1097_00000539_199612000_00003
crossref_primary_10_1016_S0894_7317_14_80002_3
crossref_primary_10_1046_j_1365_2044_2001_01981_x
crossref_primary_10_1007_BF01712161
crossref_primary_10_1007_BF01137705
crossref_primary_10_1016_S0894_7317_05_80382_7
crossref_primary_10_1053_jcan_2000_9439
crossref_primary_10_1053_j_jvca_2004_05_017
crossref_primary_10_1016_S0002_8703_96_90536_0
crossref_primary_10_1111_j_1540_8175_1999_tb00789_x
crossref_primary_10_1016_S0950_3501_98_80020_2
crossref_primary_10_1097_00003643_199707000_00002
crossref_primary_10_1097_00003643_200111000_00003
crossref_primary_10_1097_00000542_199709001_00058
crossref_primary_10_1016_S0894_7317_98_70054_9
crossref_primary_10_1161_01_CIR_95_8_2082
crossref_primary_10_1016_S0889_8537_01_80013_4
crossref_primary_10_1111_j_1540_8175_1999_tb00133_x
crossref_primary_10_1007_BF03011734
crossref_primary_10_1177_108925320601000117
crossref_primary_10_1186_cc5140
crossref_primary_10_1016_S1053_0770_97_90223_8
crossref_primary_10_1016_S0894_7317_97_70116_0
crossref_primary_10_1016_0735_1097_93_90201_B
crossref_primary_10_1016_0953_7112_93_90028_C
crossref_primary_10_1016_0002_8703_94_90493_6
crossref_primary_10_1053_j_jvca_2006_01_014
crossref_primary_10_1016_S0950_3501_98_80016_0
crossref_primary_10_1111_j_1365_2044_1998_tb15131_x
crossref_primary_10_1016_S1441_2772_23_01927_0
crossref_primary_10_1097_00004311_200201000_00007
crossref_primary_10_1111_j_1540_8175_1997_tb00685_x
crossref_primary_10_1016_S1283_0771_09_70275_0
crossref_primary_10_1016_S0749_0704_05_70248_7
crossref_primary_10_1111_j_1399_6576_1997_tb04911_x
crossref_primary_10_1016_S0733_8651_18_30156_5
ContentType Journal Article
Copyright 1993 INIST-CNRS
Copyright_xml – notice: 1993 INIST-CNRS
DBID IQODW
CGR
CUY
CVF
ECM
EIF
NPM
AAYXX
CITATION
7X8
DOI 10.1097/00000542-199303000-00011
DatabaseName Pascal-Francis
Medline
MEDLINE
MEDLINE (Ovid)
MEDLINE
MEDLINE
PubMed
CrossRef
MEDLINE - Academic
DatabaseTitle MEDLINE
Medline Complete
MEDLINE with Full Text
PubMed
MEDLINE (Ovid)
CrossRef
MEDLINE - Academic
DatabaseTitleList MEDLINE
MEDLINE - Academic
Database_xml – sequence: 1
  dbid: NPM
  name: PubMed
  url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed
  sourceTypes: Index Database
– sequence: 2
  dbid: EIF
  name: MEDLINE
  url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search
  sourceTypes: Index Database
DeliveryMethod fulltext_linktorsrc
EISSN 1528-1175
EndPage 485
ExternalDocumentID 10_1097_00000542_199303000_00011
8457048
4667674
Genre Research Support, U.S. Gov't, P.H.S
Journal Article
GrantInformation_xml – fundername: NIA NIH HHS
  grantid: 2P01AG03104-08
GroupedDBID ---
-~X
.-D
.3C
.55
.GJ
.XZ
.Z2
01R
026
08R
0R~
1CY
1J1
23M
2WC
354
40H
4Q1
4Q2
4Q3
53G
5GY
5RE
5VS
6J9
71W
77Y
7O~
AAAXR
AAEJM
AAGIX
AAHPQ
AAJCS
AAMOA
AAMTA
AAPBV
AAQKA
AAQQT
AARTV
AASOK
AASXQ
AAUGY
AAWTL
AAXQO
ABASU
ABBUW
ABDIG
ABOCM
ABPTK
ABXVJ
ABZAD
ACCJW
ACDDN
ACEWG
ACGFO
ACGFS
ACILI
ACLED
ACOAL
ACRZS
ACWDW
ACWRI
ACXNZ
ADBBV
ADFPA
ADGGA
ADNKB
AE3
AE6
AEBDS
AEETU
AENEX
AFDTB
AFFNX
AFUWQ
AGINI
AHOMT
AHRYX
AHVBC
AHXIK
AIJEX
AJIOK
AJJEV
AJNWD
AJNYG
AJRGT
AKALU
AKULP
ALMA_UNASSIGNED_HOLDINGS
ALMTX
AMJPA
AMKUR
AMNEI
AOHHW
AWKKM
BAWUL
BCGUY
BOYCO
BQLVK
BS7
BYPQX
C45
CS3
DIK
DIWNM
DUNZO
E.X
EBS
EEVPB
EJD
EX3
F2K
F2L
F2M
F2N
F5P
FCALG
FL-
FW0
GNXGY
GQDEL
GX1
H0~
HZ~
IKREB
IKYAY
IN~
IPNFZ
IQODW
J5H
JF7
JF9
JG8
JK3
JK8
K-A
K-F
K8S
KD2
KMI
L-C
L7B
M18
N4W
N9A
N~7
N~B
N~M
O9-
OAG
OAH
OB3
OBH
OCUKA
ODA
ODMTH
ODZKP
OGROG
OHH
OHYEH
OJAPA
OK1
OL1
OLB
OLG
OLH
OLL
OLU
OLV
OLW
OLY
OLZ
OPUJH
ORVUJ
OUVQU
OVD
OVDNE
OVIDH
OVLEI
OVOZU
OWU
OWV
OWW
OWX
OWY
OWZ
OXXIT
P-K
P2P
R58
RIG
RLZ
S4R
S4S
T8P
TEORI
TR2
TSPGW
TWZ
V2I
W2D
W3M
WH7
WOQ
WOW
X3V
X3W
X7M
XXN
XYM
YFH
YOC
YQI
YQJ
ZA5
ZFV
ZGI
ZXP
ZY1
ZZMQN
AAAAV
AAIQE
AASCR
AAUEB
ABJNI
ABVCZ
ACLDA
ACXJB
ADHPY
AFEXH
AFSOK
AHQNM
AINUH
AJZMW
CGR
CUY
CVF
ECM
EIF
ERAAH
HLJTE
NPM
AAYXX
CITATION
7X8
ID FETCH-LOGICAL-c484t-486eaf3031dccd3b52310c5b9dd3696fc7062d4f990dfe93c56e4f053b8279d33
ISSN 0003-3022
IngestDate Fri Oct 25 22:16:06 EDT 2024
Fri Aug 23 03:21:35 EDT 2024
Wed Oct 16 00:50:06 EDT 2024
Sun Oct 29 17:07:07 EDT 2023
IsDoiOpenAccess false
IsOpenAccess true
IsPeerReviewed true
IsScholarly true
Issue 3
Keywords Sonography
Human
Echocardiography
Image processing
Left ventricle performance
Real time
Ultrasonic transducer
Computer aid
Left ventricle
Esophagus
Language English
License CC BY 4.0
LinkModel OpenURL
MergedId FETCHMERGED-LOGICAL-c484t-486eaf3031dccd3b52310c5b9dd3696fc7062d4f990dfe93c56e4f053b8279d33
Notes ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
OpenAccessLink https://pubs.asahq.org/anesthesiology/article-pdf/78/3/477/325668/0000542-199303000-00011.pdf
PMID 8457048
PQID 75651403
PQPubID 23479
PageCount 9
ParticipantIDs proquest_miscellaneous_75651403
crossref_primary_10_1097_00000542_199303000_00011
pubmed_primary_8457048
pascalfrancis_primary_4667674
PublicationCentury 1900
PublicationDate 1993-03-01
PublicationDateYYYYMMDD 1993-03-01
PublicationDate_xml – month: 03
  year: 1993
  text: 1993-03-01
  day: 01
PublicationDecade 1990
PublicationPlace Hagerstown, MD
PublicationPlace_xml – name: Hagerstown, MD
– name: United States
PublicationTitle Anesthesiology (Philadelphia)
PublicationTitleAlternate Anesthesiology
PublicationYear 1993
Publisher Lippincott
Publisher_xml – name: Lippincott
SSID ssj0007538
Score 1.720411
Snippet Although transesophageal echocardiography (TEE) produces real-time images depicting left ventricular (LV) filling and ejection, the quantitative analysis of...
BACKGROUNDAlthough transesophageal echocardiography (TEE) produces real-time images depicting left ventricular (LV) filling and ejection, the quantitative...
SourceID proquest
crossref
pubmed
pascalfrancis
SourceType Aggregation Database
Index Database
StartPage 477
SubjectTerms Adult
Aged
Aged, 80 and over
Biological and medical sciences
Cardiovascular system
Diastole
Echocardiography - instrumentation
Echocardiography - methods
Esophagus
Female
Heart Ventricles - diagnostic imaging
Humans
Image Enhancement - methods
Image Processing, Computer-Assisted - methods
Investigative techniques, diagnostic techniques (general aspects)
Male
Medical sciences
Middle Aged
Monitoring, Intraoperative
Papillary Muscles - diagnostic imaging
Prospective Studies
Signal Processing, Computer-Assisted
Systole
Time Factors
Ultrasonic investigative techniques
Ventricular Function, Left
Title Automated real-time analysis of intraoperative transesophageal echocardiograms
URI https://www.ncbi.nlm.nih.gov/pubmed/8457048
https://search.proquest.com/docview/75651403
Volume 78
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1Lb9NAEF6FckFCFRVUBCj40BtyVHt3_ThaIRBVSTk0kXKz7H0IJBRHjXPhB_C7O7O7foUioBcrsmJHnpl88_A3M4Rc6gL8DOfCLxOtfZYiDupA-0GsOQ2LQkVm3dvyJpqv2fWGb0ajXz3W0qEuJ-Lng30lj9EqnAO9Ypfsf2i2vSmcgM-gXziChuH4TzrODnUFEafCDpTih4974j8WvSkj37FyW-2Um-5do19SuLcAQARUowD6hOGjIkVr349TM0BACA33bkQThKFYecGRkrtvSK9tywfTbDXPFpkhCywnXdEUIHp2O10POsiWs8Xqq_nmfNJ1QGSfFpaNcdtVICzfjw4qEO0kiQHQUp9e2ZbjiXLYGkLCGthFKQ34xknPyGgPSZnb7mKdMrN7fX7DeztH2GQ6nIXImgGX7JrlHYgPRmwfub6WkMiQ6huzJ-RpCICF1MAvm44qBCld0mxexIdyjLBm-OdDPz0Ic57vij3847RdlfLnXMbENKsX5NQlI15mLeuMjNT2JblprcprrcprrMqrtDe0Ku_Iqrwjq3pF1p9nq-ncd1s3fMESVvssiVSh4VkCKYSkJccMQPAylRJ3P2oRX0WhZBrCGKlVSgWPFNOA5WUCspOUnpOTbbVVr0FIEZVchlTIlDGlAAlYGpapLnmsNTiTMQkaIeU7O1wl75EijGDzVrCGJxGMycVAmu2FToVj8qGRbg5Iia-_iq2qDvs8htwFp1OOybkVentpwngMnuzNX279ljzrzP8dOanvDuoCQtK6fG_s5R7ToIWr
link.rule.ids 315,783,787,27938,27939
linkProvider Geneva Foundation for Medical Education and Research
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Automated+real-time+analysis+of+intraoperative+transesophageal+echocardiograms&rft.jtitle=Anesthesiology+%28Philadelphia%29&rft.au=CATHALAN%2C+M.+K&rft.au=IONESCU%2C+P&rft.au=MELTON%2C+H.+E&rft.au=ADLER%2C+S&rft.date=1993-03-01&rft.pub=Lippincott&rft.issn=0003-3022&rft.eissn=1528-1175&rft.volume=78&rft.issue=3&rft.spage=477&rft.epage=485&rft_id=info:doi/10.1097%2F00000542-199303000-00011&rft.externalDBID=n%2Fa&rft.externalDocID=4667674
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0003-3022&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0003-3022&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0003-3022&client=summon