The potential relationship between EasyNAT system Tt values and Cobas z480 Ct values in the detection of SARS-Cov-2

This study aimed to evaluate the potential relationship between the time threshold (Tt) values of a commercial EasyNAT system, which is based on cross priming amplification (CPA) technology, and the cycle threshold (Ct) values of the Cobas z480 analyzer, which is based on a real-time fluorescence po...

Full description

Saved in:
Bibliographic Details
Published inPractical laboratory medicine Vol. 42; p. e00431
Main Authors Zheng, Lu-Qing, Wang, Qing-Yong
Format Journal Article
LanguageEnglish
Published Netherlands Elsevier B.V 01.11.2024
Elsevier
Subjects
Online AccessGet full text

Cover

Loading…
Abstract This study aimed to evaluate the potential relationship between the time threshold (Tt) values of a commercial EasyNAT system, which is based on cross priming amplification (CPA) technology, and the cycle threshold (Ct) values of the Cobas z480 analyzer, which is based on a real-time fluorescence polymerase chain reaction (PCR) method, in the detection of severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) from oropharyngeal swabs. Design and Methods: Data were retrospectively collected from a clinical laboratory between December 4, 2022 and July 1, 2024. A total of 277 EasyNAT-positive samples (Tt values from 3.83 to 29.5) were simultaneously investigated using the Cobas z480 analyzer (Ct values from 10.74 to 38.78). The concordance rate between the two systems was 100 %. Among the positive samples, the mean and maximum PCR Ct values of O and N genes increased in line with increasing Tt values of the left and right amplification areas of the EasyNAT system. The maximum Ct values of the O or N gene determined by the Cobas z480 analyzer were no more than 29.52 when the Tt values of the left or right amplification areas of the UC0116 analyzer were no more than 6. The safe, simple, fast, accurate, and automatic EasyNAT system used in conjunction with a PCR system might be a better choice for the detection of SARS-CoV-2 in hospitals, especially in settings without sophisticated PCR facilities. The Tt value (≤6) of the EasyNAT system can be a reference index for estimating the maximum Ct value (29.52) in SARS-CoV-2-positive samples.
AbstractList This study aimed to evaluate the potential relationship between the time threshold (Tt) values of a commercial EasyNAT system, which is based on cross priming amplification (CPA) technology, and the cycle threshold (Ct) values of the Cobas z480 analyzer, which is based on a real-time fluorescence polymerase chain reaction (PCR) method, in the detection of severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) from oropharyngeal swabs. Design and Methods: Data were retrospectively collected from a clinical laboratory between December 4, 2022 and July 1, 2024. A total of 277 EasyNAT-positive samples (Tt values from 3.83 to 29.5) were simultaneously investigated using the Cobas z480 analyzer (Ct values from 10.74 to 38.78). The concordance rate between the two systems was 100 %. Among the positive samples, the mean and maximum PCR Ct values of O and N genes increased in line with increasing Tt values of the left and right amplification areas of the EasyNAT system. The maximum Ct values of the O or N gene determined by the Cobas z480 analyzer were no more than 29.52 when the Tt values of the left or right amplification areas of the UC0116 analyzer were no more than 6. The safe, simple, fast, accurate, and automatic EasyNAT system used in conjunction with a PCR system might be a better choice for the detection of SARS-CoV-2 in hospitals, especially in settings without sophisticated PCR facilities. The Tt value (≤6) of the EasyNAT system can be a reference index for estimating the maximum Ct value (29.52) in SARS-CoV-2-positive samples.
This study aimed to evaluate the potential relationship between the time threshold (Tt) values of a commercial EasyNAT system, which is based on cross priming amplification (CPA) technology, and the cycle threshold (Ct) values of the Cobas z480 analyzer, which is based on a real-time fluorescence polymerase chain reaction (PCR) method, in the detection of severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) from oropharyngeal swabs. Design and Methods: Data were retrospectively collected from a clinical laboratory between December 4, 2022 and July 1, 2024.ObjectivesThis study aimed to evaluate the potential relationship between the time threshold (Tt) values of a commercial EasyNAT system, which is based on cross priming amplification (CPA) technology, and the cycle threshold (Ct) values of the Cobas z480 analyzer, which is based on a real-time fluorescence polymerase chain reaction (PCR) method, in the detection of severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) from oropharyngeal swabs. Design and Methods: Data were retrospectively collected from a clinical laboratory between December 4, 2022 and July 1, 2024.A total of 277 EasyNAT-positive samples (Tt values from 3.83 to 29.5) were simultaneously investigated using the Cobas z480 analyzer (Ct values from 10.74 to 38.78). The concordance rate between the two systems was 100 %. Among the positive samples, the mean and maximum PCR Ct values of O and N genes increased in line with increasing Tt values of the left and right amplification areas of the EasyNAT system. The maximum Ct values of the O or N gene determined by the Cobas z480 analyzer were no more than 29.52 when the Tt values of the left or right amplification areas of the UC0116 analyzer were no more than 6.ResultsA total of 277 EasyNAT-positive samples (Tt values from 3.83 to 29.5) were simultaneously investigated using the Cobas z480 analyzer (Ct values from 10.74 to 38.78). The concordance rate between the two systems was 100 %. Among the positive samples, the mean and maximum PCR Ct values of O and N genes increased in line with increasing Tt values of the left and right amplification areas of the EasyNAT system. The maximum Ct values of the O or N gene determined by the Cobas z480 analyzer were no more than 29.52 when the Tt values of the left or right amplification areas of the UC0116 analyzer were no more than 6.The safe, simple, fast, accurate, and automatic EasyNAT system used in conjunction with a PCR system might be a better choice for the detection of SARS-CoV-2 in hospitals, especially in settings without sophisticated PCR facilities. The Tt value (≤6) of the EasyNAT system can be a reference index for estimating the maximum Ct value (29.52) in SARS-CoV-2-positive samples.ConclusionsThe safe, simple, fast, accurate, and automatic EasyNAT system used in conjunction with a PCR system might be a better choice for the detection of SARS-CoV-2 in hospitals, especially in settings without sophisticated PCR facilities. The Tt value (≤6) of the EasyNAT system can be a reference index for estimating the maximum Ct value (29.52) in SARS-CoV-2-positive samples.
Objectives: This study aimed to evaluate the potential relationship between the time threshold (Tt) values of a commercial EasyNAT system, which is based on cross priming amplification (CPA) technology, and the cycle threshold (Ct) values of the Cobas z480 analyzer, which is based on a real-time fluorescence polymerase chain reaction (PCR) method, in the detection of severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) from oropharyngeal swabs. Design and Methods: Data were retrospectively collected from a clinical laboratory between December 4, 2022 and July 1, 2024. Results: A total of 277 EasyNAT-positive samples (Tt values from 3.83 to 29.5) were simultaneously investigated using the Cobas z480 analyzer (Ct values from 10.74 to 38.78). The concordance rate between the two systems was 100 %. Among the positive samples, the mean and maximum PCR Ct values of O and N genes increased in line with increasing Tt values of the left and right amplification areas of the EasyNAT system. The maximum Ct values of the O or N gene determined by the Cobas z480 analyzer were no more than 29.52 when the Tt values of the left or right amplification areas of the UC0116 analyzer were no more than 6. Conclusions: The safe, simple, fast, accurate, and automatic EasyNAT system used in conjunction with a PCR system might be a better choice for the detection of SARS-CoV-2 in hospitals, especially in settings without sophisticated PCR facilities. The Tt value (≤6) of the EasyNAT system can be a reference index for estimating the maximum Ct value (29.52) in SARS-CoV-2-positive samples.
ArticleNumber e00431
Author Wang, Qing-Yong
Zheng, Lu-Qing
Author_xml – sequence: 1
  givenname: Lu-Qing
  surname: Zheng
  fullname: Zheng, Lu-Qing
  email: xyyywsw@163.com
– sequence: 2
  givenname: Qing-Yong
  surname: Wang
  fullname: Wang, Qing-Yong
  email: qywpumc@sina.com
BackLink https://www.ncbi.nlm.nih.gov/pubmed/39411185$$D View this record in MEDLINE/PubMed
BookMark eNp9ktFv0zAQxiM0xMbYX4CE_MhLis9x4vgBoaoaMGkCiZVn6-JcVldpXGK3U_nrccmotheebPm--5383fc6Oxv8QFn2FvgMOFQf1rNtj81mJriQM-JcFvAiuxBFKfKyBHX25H6eXYWw5pxDrZTm4lV2XmgJAHV5kYXlitjWRxqiw56N1GN0fggrt2UNxQeigV1jOHybL1k4hEgbtoxsj_2OAsOhZQvfYGC_Zc3Z4lRwA4uJ21Ike8Qx37G7-Y-7fOH3uXiTveywD3T1eF5mPz9fLxdf89vvX24W89vcSlXFvLFatdQiVdBCjcBlW0td100LvBBClp2iirBWWikuGq2tFFxDVwrkUtmyuMxuJm7rcW22o9vgeDAenfn74Md7g2N0tieDQnJhsYKGSEqLDQrRoa6FKiXoWibWp4m13TUbam3ya8T-GfR5ZXArc-_3BkAqCapKhPePhNH_SiZFs3HBUt_jQH4XTAGguNJpWpK-ezrsNOXf2pKgmAR29CGM1J0kwM0xHyb995gPc8yHmfKRuj5OXZRM3zsaTbCOBkutG9Oekivuv_1_AIicwtY
Cites_doi 10.1016/j.jviromet.2019.113678
10.1186/s12941-021-00443-w
10.1038/srep00246
10.1016/j.jiph.2021.08.013
10.4315/0362-028X.JFP-19-156
10.1111/lam.12342
10.1007/s40291-022-00631-0
ContentType Journal Article
Copyright 2024
2024 Published by Elsevier B.V.
2024 Published by Elsevier B.V. 2024
Copyright_xml – notice: 2024
– notice: 2024 Published by Elsevier B.V.
– notice: 2024 Published by Elsevier B.V. 2024
DBID 6I.
AAFTH
AAYXX
CITATION
NPM
7X8
5PM
DOA
DOI 10.1016/j.plabm.2024.e00431
DatabaseName ScienceDirect Open Access Titles
Elsevier:ScienceDirect:Open Access
CrossRef
PubMed
MEDLINE - Academic
PubMed Central (Full Participant titles)
Directory of Open Access Journals (DOAJ)
DatabaseTitle CrossRef
PubMed
MEDLINE - Academic
DatabaseTitleList PubMed
MEDLINE - Academic


Database_xml – sequence: 1
  dbid: DOA
  name: Acceso a contenido Full Text - Doaj
  url: https://www.doaj.org/
  sourceTypes: Open Website
– sequence: 2
  dbid: NPM
  name: PubMed
  url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed
  sourceTypes: Index Database
DeliveryMethod fulltext_linktorsrc
Discipline Medicine
EISSN 2352-5517
ExternalDocumentID oai_doaj_org_article_a2402ca61bee44caba22fa9827541984
PMC11474176
39411185
10_1016_j_plabm_2024_e00431
S2352551724000775
Genre Journal Article
GroupedDBID 0R~
0SF
4.4
457
53G
6I.
AACTN
AAEDW
AAFTH
AAFWJ
AALRI
AAXUO
ABMAC
ACGFS
ADBBV
ADEZE
ADVLN
AEXQZ
AFJKZ
AFPKN
AFTJW
AGHFR
AITUG
AKRWK
ALMA_UNASSIGNED_HOLDINGS
AMRAJ
AOIJS
BCNDV
EBS
EJD
FDB
GROUPED_DOAJ
HYE
KQ8
M~E
NCXOZ
O9-
OK1
ROL
RPM
SSZ
AAYWO
AAYXX
ACVFH
ADCNI
AEUPX
AFPUW
AIGII
AKBMS
AKYEP
APXCP
CITATION
NPM
7X8
5PM
ID FETCH-LOGICAL-c476t-bc97dedae61d18a104d84988bd1032245f7e6ea8797702b99c42091f52a047c53
IEDL.DBID DOA
ISSN 2352-5517
IngestDate Wed Aug 27 01:30:09 EDT 2025
Thu Aug 21 18:30:43 EDT 2025
Fri Jul 11 07:03:22 EDT 2025
Thu Jan 02 22:30:02 EST 2025
Tue Jul 01 03:18:41 EDT 2025
Sat Dec 28 15:50:10 EST 2024
IsDoiOpenAccess true
IsOpenAccess true
IsPeerReviewed true
IsScholarly true
Keywords EasyNAT system
Time threshold
Cycle threshold
SARS-CoV-2
Cobas z480
Language English
License This is an open access article under the CC BY-NC-ND license.
2024 Published by Elsevier B.V.
This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
LinkModel DirectLink
MergedId FETCHMERGED-LOGICAL-c476t-bc97dedae61d18a104d84988bd1032245f7e6ea8797702b99c42091f52a047c53
Notes ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
OpenAccessLink https://doaj.org/article/a2402ca61bee44caba22fa9827541984
PMID 39411185
PQID 3117079198
PQPubID 23479
ParticipantIDs doaj_primary_oai_doaj_org_article_a2402ca61bee44caba22fa9827541984
pubmedcentral_primary_oai_pubmedcentral_nih_gov_11474176
proquest_miscellaneous_3117079198
pubmed_primary_39411185
crossref_primary_10_1016_j_plabm_2024_e00431
elsevier_sciencedirect_doi_10_1016_j_plabm_2024_e00431
ProviderPackageCode CITATION
AAYXX
PublicationCentury 2000
PublicationDate 2024-11-01
PublicationDateYYYYMMDD 2024-11-01
PublicationDate_xml – month: 11
  year: 2024
  text: 2024-11-01
  day: 01
PublicationDecade 2020
PublicationPlace Netherlands
PublicationPlace_xml – name: Netherlands
PublicationTitle Practical laboratory medicine
PublicationTitleAlternate Pract Lab Med
PublicationYear 2024
Publisher Elsevier B.V
Elsevier
Publisher_xml – name: Elsevier B.V
– name: Elsevier
References Zhang, Wang, Jia (bib3) 2019; 274
Al Bayat, Mundodan, Hasnain (bib8) 2021; 14
Wang, Li (bib2) 2021; 67
Wu, Shi, Chen (bib7) 2021; 20
Bai, Xie, You (bib5) 2015; 60
Xu, Hu, Zhong (bib6) 2012; 2
Li, Wang, Geng, Xiao, Wang (bib1) 2023; 27
Zhang, Di, Shan (bib4) 2019; 82
Zhang (10.1016/j.plabm.2024.e00431_bib3) 2019; 274
Xu (10.1016/j.plabm.2024.e00431_bib6) 2012; 2
Zhang (10.1016/j.plabm.2024.e00431_bib4) 2019; 82
Al Bayat (10.1016/j.plabm.2024.e00431_bib8) 2021; 14
Wu (10.1016/j.plabm.2024.e00431_bib7) 2021; 20
Bai (10.1016/j.plabm.2024.e00431_bib5) 2015; 60
Li (10.1016/j.plabm.2024.e00431_bib1) 2023; 27
Wang (10.1016/j.plabm.2024.e00431_bib2) 2021; 67
References_xml – volume: 67
  year: 2021
  ident: bib2
  article-title: Setting up a PCR laboratory for the detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2)
  publication-title: Clin. Lab.
– volume: 20
  start-page: 38
  year: 2021
  ident: bib7
  article-title: Comparative evaluation of six nucleic acid amplification kits for SARS-CoV-2 RNA detection
  publication-title: Ann. Clin. Microbiol. Antimicrob.
– volume: 14
  start-page: 1201
  year: 2021
  end-page: 1205
  ident: bib8
  article-title: Can the cycle threshold (Ct) value of RT-PCR test for SARS CoV2 predict infectivity among close contacts?
  publication-title: J. Infect Public Health
– volume: 27
  start-page: 159
  year: 2023
  end-page: 177
  ident: bib1
  article-title: Emerging landscape of SARS-CoV-2 variants and detection technologies
  publication-title: Mol. Diagn. Ther.
– volume: 60
  start-page: 205
  year: 2015
  end-page: 209
  ident: bib5
  article-title: Isothermal cross-priming amplification implementation study
  publication-title: Lett. Appl. Microbiol.
– volume: 274
  year: 2019
  ident: bib3
  article-title: Rapid detection of giant salamander iridovirus by cross-priming amplification
  publication-title: J. Virol Methods
– volume: 82
  start-page: 1744
  year: 2019
  end-page: 1750
  ident: bib4
  article-title: Rapid detection of Bacillus cereus using cross-priming amplification
  publication-title: J. Food Protect.
– volume: 2
  start-page: 246
  year: 2012
  ident: bib6
  article-title: Cross priming amplification: mechanism and optimization for isothermal DNA amplification
  publication-title: Sci. Rep.
– volume: 274
  year: 2019
  ident: 10.1016/j.plabm.2024.e00431_bib3
  article-title: Rapid detection of giant salamander iridovirus by cross-priming amplification
  publication-title: J. Virol Methods
  doi: 10.1016/j.jviromet.2019.113678
– volume: 20
  start-page: 38
  issue: 1
  year: 2021
  ident: 10.1016/j.plabm.2024.e00431_bib7
  article-title: Comparative evaluation of six nucleic acid amplification kits for SARS-CoV-2 RNA detection
  publication-title: Ann. Clin. Microbiol. Antimicrob.
  doi: 10.1186/s12941-021-00443-w
– volume: 67
  issue: 12
  year: 2021
  ident: 10.1016/j.plabm.2024.e00431_bib2
  article-title: Setting up a PCR laboratory for the detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2)
  publication-title: Clin. Lab.
– volume: 2
  start-page: 246
  year: 2012
  ident: 10.1016/j.plabm.2024.e00431_bib6
  article-title: Cross priming amplification: mechanism and optimization for isothermal DNA amplification
  publication-title: Sci. Rep.
  doi: 10.1038/srep00246
– volume: 14
  start-page: 1201
  issue: 9
  year: 2021
  ident: 10.1016/j.plabm.2024.e00431_bib8
  article-title: Can the cycle threshold (Ct) value of RT-PCR test for SARS CoV2 predict infectivity among close contacts?
  publication-title: J. Infect Public Health
  doi: 10.1016/j.jiph.2021.08.013
– volume: 82
  start-page: 1744
  issue: 10
  year: 2019
  ident: 10.1016/j.plabm.2024.e00431_bib4
  article-title: Rapid detection of Bacillus cereus using cross-priming amplification
  publication-title: J. Food Protect.
  doi: 10.4315/0362-028X.JFP-19-156
– volume: 60
  start-page: 205
  issue: 3
  year: 2015
  ident: 10.1016/j.plabm.2024.e00431_bib5
  article-title: Isothermal cross-priming amplification implementation study
  publication-title: Lett. Appl. Microbiol.
  doi: 10.1111/lam.12342
– volume: 27
  start-page: 159
  issue: 2
  year: 2023
  ident: 10.1016/j.plabm.2024.e00431_bib1
  article-title: Emerging landscape of SARS-CoV-2 variants and detection technologies
  publication-title: Mol. Diagn. Ther.
  doi: 10.1007/s40291-022-00631-0
SSID ssj0001877902
Score 2.2819738
Snippet This study aimed to evaluate the potential relationship between the time threshold (Tt) values of a commercial EasyNAT system, which is based on cross priming...
Objectives: This study aimed to evaluate the potential relationship between the time threshold (Tt) values of a commercial EasyNAT system, which is based on...
SourceID doaj
pubmedcentral
proquest
pubmed
crossref
elsevier
SourceType Open Website
Open Access Repository
Aggregation Database
Index Database
Publisher
StartPage e00431
SubjectTerms Cobas z480
Cycle threshold
EasyNAT system
SARS-CoV-2
Short Communication
Time threshold
Title The potential relationship between EasyNAT system Tt values and Cobas z480 Ct values in the detection of SARS-Cov-2
URI https://dx.doi.org/10.1016/j.plabm.2024.e00431
https://www.ncbi.nlm.nih.gov/pubmed/39411185
https://www.proquest.com/docview/3117079198
https://pubmed.ncbi.nlm.nih.gov/PMC11474176
https://doaj.org/article/a2402ca61bee44caba22fa9827541984
Volume 42
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwrV1La9wwEBYlhdJL6bvbPFChx7q1ZVmWjpslITQkh2RDcxOSPCabg73ETiD99R1J9rJuob30ahlZM9_IMyONPhHymWUOUlA2YQ7TVc5snliVuSTnplbC4R8wLA2cnYuTK_79urjeuurL14RFeuCouG_GL_87IzILwLkz1jBWGyVZWXBMmAMTKPq8rWQqrK5Iz6PHRpqhUNC1RrX6s-eMfwW_AZZNXFFg7J94pD8jzt8LJ7c80fFL8mIIIek8Dv0VeQLNa_LsbNgkf0M6hJ6u297XAeF7d2O5281qTYeyLHpkusfz-ZJGIme67Kln_YaOmqaiC5zjHf3JZUoXm4ZVQzFWpBX0oXiroW1NL-cXl8mifUjYW3J1fLRcnCTD3QqJ46XoE-tUWUFlQGRVJg0mZZXkSkpbeYY9xou6BAFGlhgfpswqhbChmuuCmZSXrsjfkZ2mbeADoQqYFXlWSJMCr5mQLHc5w56NUxKRmpEvo5r1OlJo6LG27FYHVLRHRUdUZuTQQ7F51fNfhwdoFXqwCv0vq5gRMQKph1AihgjY1ervX_80wq5xovndE9NAe9_p3N_RU6rMC_Q-msFmjLni6DNkMSNyYiATIaYtzeomkHljPopBXSk-_g-xd8lzL0s8K7lHdvq7e9jHoKm3B-Tp_PTix-lBmCe_AMEKFY8
linkProvider Directory of Open Access Journals
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=The+potential+relationship+between+EasyNAT+system+Tt+values+and+Cobas+z480+Ct+values+in+the+detection+of+SARS-Cov-2&rft.jtitle=Practical+laboratory+medicine&rft.au=Zheng%2C+Lu-Qing&rft.au=Wang%2C+Qing-Yong&rft.date=2024-11-01&rft.issn=2352-5517&rft.eissn=2352-5517&rft.volume=42&rft.spage=e00431&rft_id=info:doi/10.1016%2Fj.plabm.2024.e00431&rft_id=info%3Apmid%2F39411185&rft.externalDocID=39411185
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=2352-5517&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=2352-5517&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=2352-5517&client=summon