Near work-induced transient myopia in Indian subjects

The aim was to determine the characteristics of near work-induced transient myopia (NITM) in asymptomatic Indian subjects and the influence of target size and contrast. Two studies were conducted: First, 24 myopes and 24 emmetropes viewed four targets (N8 and N12 with 50 and 90 per cent contrasts) p...

Full description

Saved in:
Bibliographic Details
Published inClinical and experimental optometry Vol. 98; no. 6; pp. 541 - 546
Main Authors Sivaraman, Viswanathan, Rizwana, Jameel H, Ramani, Krishnakumar, Price, Holly, Calver, Richard, Pardhan, Shahina, Vasudevan, Balamurali, Allen, Peter M
Format Journal Article
LanguageEnglish
Published Australia Taylor & Francis 01.11.2015
Subjects
Online AccessGet full text
ISSN0816-4622
1444-0938
DOI10.1111/cxo.12306

Cover

More Information
Summary:The aim was to determine the characteristics of near work-induced transient myopia (NITM) in asymptomatic Indian subjects and the influence of target size and contrast. Two studies were conducted: First, 24 myopes and 24 emmetropes viewed four targets (N8 and N12 with 50 and 90 per cent contrasts) placed at 0.2-m for five minutes. The refractive status was assessed objectively, before and after carrying out the near task, with the Grand Seiko WAM-5500 open-field autorefractor under monocular viewing conditions. Second, a different group of 24 myopes and 24 emmetropes viewed a N12 target with 90 per cent contrast for 60-minutes with pre- and post-refractive state measurements repeated as above. NITM was defined as the difference between pre-task and post-task distance refraction. In the first study, myopes demonstrated an initial post-task myopic shift of 0.21 D, whereas emmetropes demonstrated a small hyperopic shift of 0.07 D (p < 0.001). The myopes demonstrated a decay time constant of 6.07-seconds. There was no effect of target size or contrast on the magnitude of the NITM or the decay time constant (p > 0.05). In the second study, myopes showed a NITM of 0.31 D, which was significantly greater than emmetropes (p < 0.001). The myopes demonstrated a decay time constant of 8.16-seconds. The magnitude of the NITM was higher in myopes compared to emmetropes for both five minute and 60-minute viewing time. The NITM decayed slightly faster than that found in previous literature for some other ethnic groups. Potential reasons for these findings are discussed.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0816-4622
1444-0938
DOI:10.1111/cxo.12306