Hip replacement femoral implants are made of substantial materials that all have stiffness considerably higher than that of bone, which can cause significant bone resorption secondary to stress shielding and lead to severe complications. The topology optimization design method based on the uniform d...

Full description

Saved in:
Bibliographic Details
Published inMaterials Vol. 16; no. 8; p. 3151
Main Authors Xiao, Zhongmin, Wu, Longfei, Wu, Wenqiang, Tang, Ruizhi, Dai, Jietao, Zhu, Dachang
Format Journal Article
LanguageEnglish
Published Switzerland MDPI AG 17.04.2023
MDPI
Subjects
Online AccessGet full text
ISSN1996-1944
1996-1944
DOI10.3390/ma16083151

Cover

Loading…
Abstract Hip replacement femoral implants are made of substantial materials that all have stiffness considerably higher than that of bone, which can cause significant bone resorption secondary to stress shielding and lead to severe complications. The topology optimization design method based on the uniform distribution of material micro-structure density can form a continuous mechanical transmission route, which can better solve the problem of reducing the stress shielding effect. A multi-scale parallel topology optimization method is proposed in this paper and a topological structure of type B femoral stem is derived. Using the traditional topology optimization method (Solid Isotropic Material with Penalization, SIMP), a topological structure of type A femoral stem is also derived. The sensitivity of the two kinds of femoral stems to the change of load direction is compared with the variation amplitude of the structural flexibility of the femoral stem. Furthermore, the finite element method is used to analyze the stress of type A and type B femoral stem under multiple conditions. Simulation and experimental results show that the average stress of type A and type B femoral stem on the femur are 14.80 MPa, 23.55 MPa, 16.94 MPa and 10.89 MPa, 20.92 MPa, 16.50 MPa, respectively. For type B femoral stem, the average error of strain is −1682με and the average relative error is 20.3% at the test points on the medial side and the mean error of strain is 1281με and the mean relative error is 19.5% at the test points on the outside.
AbstractList Hip replacement femoral implants are made of substantial materials that all have stiffness considerably higher than that of bone, which can cause significant bone resorption secondary to stress shielding and lead to severe complications. The topology optimization design method based on the uniform distribution of material micro-structure density can form a continuous mechanical transmission route, which can better solve the problem of reducing the stress shielding effect. A multi-scale parallel topology optimization method is proposed in this paper and a topological structure of type B femoral stem is derived. Using the traditional topology optimization method (Solid Isotropic Material with Penalization, SIMP), a topological structure of type A femoral stem is also derived. The sensitivity of the two kinds of femoral stems to the change of load direction is compared with the variation amplitude of the structural flexibility of the femoral stem. Furthermore, the finite element method is used to analyze the stress of type A and type B femoral stem under multiple conditions. Simulation and experimental results show that the average stress of type A and type B femoral stem on the femur are 14.80 MPa, 23.55 MPa, 16.94 MPa and 10.89 MPa, 20.92 MPa, 16.50 MPa, respectively. For type B femoral stem, the average error of strain is −1682με and the average relative error is 20.3% at the test points on the medial side and the mean error of strain is 1281με and the mean relative error is 19.5% at the test points on the outside.
Hip replacement femoral implants are made of substantial materials that all have stiffness considerably higher than that of bone, which can cause significant bone resorption secondary to stress shielding and lead to severe complications. The topology optimization design method based on the uniform distribution of material micro-structure density can form a continuous mechanical transmission route, which can better solve the problem of reducing the stress shielding effect. A multi-scale parallel topology optimization method is proposed in this paper and a topological structure of type B femoral stem is derived. Using the traditional topology optimization method (Solid Isotropic Material with Penalization, SIMP), a topological structure of type A femoral stem is also derived. The sensitivity of the two kinds of femoral stems to the change of load direction is compared with the variation amplitude of the structural flexibility of the femoral stem. Furthermore, the finite element method is used to analyze the stress of type A and type B femoral stem under multiple conditions. Simulation and experimental results show that the average stress of type A and type B femoral stem on the femur are 14.80 MPa, 23.55 MPa, 16.94 MPa and 10.89 MPa, 20.92 MPa, 16.50 MPa, respectively. For type B femoral stem, the average error of strain is -1682με and the average relative error is 20.3% at the test points on the medial side and the mean error of strain is 1281με and the mean relative error is 19.5% at the test points on the outside.
Hip replacement femoral implants are made of substantial materials that all have stiffness considerably higher than that of bone, which can cause significant bone resorption secondary to stress shielding and lead to severe complications. The topology optimization design method based on the uniform distribution of material micro-structure density can form a continuous mechanical transmission route, which can better solve the problem of reducing the stress shielding effect. A multi-scale parallel topology optimization method is proposed in this paper and a topological structure of type B femoral stem is derived. Using the traditional topology optimization method (Solid Isotropic Material with Penalization, SIMP), a topological structure of type A femoral stem is also derived. The sensitivity of the two kinds of femoral stems to the change of load direction is compared with the variation amplitude of the structural flexibility of the femoral stem. Furthermore, the finite element method is used to analyze the stress of type A and type B femoral stem under multiple conditions. Simulation and experimental results show that the average stress of type A and type B femoral stem on the femur are 14.80 MPa, 23.55 MPa, 16.94 MPa and 10.89 MPa, 20.92 MPa, 16.50 MPa, respectively. For type B femoral stem, the average error of strain is − 1682 μ ε and the average relative error is 20.3 % at the test points on the medial side and the mean error of strain is 1281 μ ε and the mean relative error is 19.5 % at the test points on the outside.
Hip replacement femoral implants are made of substantial materials that all have stiffness considerably higher than that of bone, which can cause significant bone resorption secondary to stress shielding and lead to severe complications. The topology optimization design method based on the uniform distribution of material micro-structure density can form a continuous mechanical transmission route, which can better solve the problem of reducing the stress shielding effect. A multi-scale parallel topology optimization method is proposed in this paper and a topological structure of type B femoral stem is derived. Using the traditional topology optimization method (Solid Isotropic Material with Penalization, SIMP), a topological structure of type A femoral stem is also derived. The sensitivity of the two kinds of femoral stems to the change of load direction is compared with the variation amplitude of the structural flexibility of the femoral stem. Furthermore, the finite element method is used to analyze the stress of type A and type B femoral stem under multiple conditions. Simulation and experimental results show that the average stress of type A and type B femoral stem on the femur are 14.80 MPa, 23.55 MPa, 16.94 MPa and 10.89 MPa, 20.92 MPa, 16.50 MPa, respectively. For type B femoral stem, the average error of strain is -1682με and the average relative error is 20.3% at the test points on the medial side and the mean error of strain is 1281με and the mean relative error is 19.5% at the test points on the outside.Hip replacement femoral implants are made of substantial materials that all have stiffness considerably higher than that of bone, which can cause significant bone resorption secondary to stress shielding and lead to severe complications. The topology optimization design method based on the uniform distribution of material micro-structure density can form a continuous mechanical transmission route, which can better solve the problem of reducing the stress shielding effect. A multi-scale parallel topology optimization method is proposed in this paper and a topological structure of type B femoral stem is derived. Using the traditional topology optimization method (Solid Isotropic Material with Penalization, SIMP), a topological structure of type A femoral stem is also derived. The sensitivity of the two kinds of femoral stems to the change of load direction is compared with the variation amplitude of the structural flexibility of the femoral stem. Furthermore, the finite element method is used to analyze the stress of type A and type B femoral stem under multiple conditions. Simulation and experimental results show that the average stress of type A and type B femoral stem on the femur are 14.80 MPa, 23.55 MPa, 16.94 MPa and 10.89 MPa, 20.92 MPa, 16.50 MPa, respectively. For type B femoral stem, the average error of strain is -1682με and the average relative error is 20.3% at the test points on the medial side and the mean error of strain is 1281με and the mean relative error is 19.5% at the test points on the outside.
Hip replacement femoral implants are made of substantial materials that all have stiffness considerably higher than that of bone, which can cause significant bone resorption secondary to stress shielding and lead to severe complications. The topology optimization design method based on the uniform distribution of material micro-structure density can form a continuous mechanical transmission route, which can better solve the problem of reducing the stress shielding effect. A multi-scale parallel topology optimization method is proposed in this paper and a topological structure of type B femoral stem is derived. Using the traditional topology optimization method (Solid Isotropic Material with Penalization, SIMP), a topological structure of type A femoral stem is also derived. The sensitivity of the two kinds of femoral stems to the change of load direction is compared with the variation amplitude of the structural flexibility of the femoral stem. Furthermore, the finite element method is used to analyze the stress of type A and type B femoral stem under multiple conditions. Simulation and experimental results show that the average stress of type A and type B femoral stem on the femur are 14.80 MPa, 23.55 MPa, 16.94 MPa and 10.89 MPa, 20.92 MPa, 16.50 MPa, respectively. For type B femoral stem, the average error of strain is −1682 με and the average relative error is 20.3% at the test points on the medial side and the mean error of strain is 1281 με and the mean relative error is 19.5% at the test points on the outside.
Audience Academic
Author Xiao, Zhongmin
Wu, Longfei
Wu, Wenqiang
Dai, Jietao
Zhu, Dachang
Tang, Ruizhi
AuthorAffiliation School of Mechanical and Electrical Engineering, Guangzhou University, Guangzhou 510006, China
AuthorAffiliation_xml – name: School of Mechanical and Electrical Engineering, Guangzhou University, Guangzhou 510006, China
Author_xml – sequence: 1
  givenname: Zhongmin
  surname: Xiao
  fullname: Xiao, Zhongmin
– sequence: 2
  givenname: Longfei
  surname: Wu
  fullname: Wu, Longfei
– sequence: 3
  givenname: Wenqiang
  surname: Wu
  fullname: Wu, Wenqiang
– sequence: 4
  givenname: Ruizhi
  surname: Tang
  fullname: Tang, Ruizhi
– sequence: 5
  givenname: Jietao
  surname: Dai
  fullname: Dai, Jietao
– sequence: 6
  givenname: Dachang
  orcidid: 0000-0002-0691-7755
  surname: Zhu
  fullname: Zhu, Dachang
BackLink https://www.ncbi.nlm.nih.gov/pubmed/37109987$$D View this record in MEDLINE/PubMed
BookMark eNptkl1rFDEUhoNUbK298QdIwBsRpuZr8nElpVgVKgV3rw3ZzJltlpnJOkkK9debta39oAkkIXnOm7w55zXam-IECL2l5JhzQz6NjkqiOW3pC3RAjZENNULsPVjvo6OUNqQ2zqlm5hXa54oSY7Q6QL9-lCGHZuHdAHgZt3GI62t8sc1hDH9cDnHCscdnMMbZDXiRYazDXHwuM-BFWW3AZ5zjbhNSwovLAEMXpjX-CV3x8Aa97N2Q4Oh2PkTLsy_L02_N-cXX76cn540XSuSGKuiY59wZJaBdMcm91oyIakH0nIlW9oITQ4nUoqdcMK2Y4do57xTRkh-izzey27IaofMw5fpcu53D6OZrG12wj0-mcGnX8cpSQgU3hleFD7cKc_xdIGU7huRhGNwEsSTLNFGG8Vaqir5_gm5imadqb0fJVjJC5T21rj9rw9THerHfidoTVU0LyRir1PEzVO0djMHXTPeh7j8KePfQ6X-LdxmtALkB_BxTmqG3PuR_iazKYaiO7a5u7H3d1JCPT0LuVJ-B_wLTQb9B
CitedBy_id crossref_primary_10_3390_jfb15080238
crossref_primary_10_3390_app14188289
crossref_primary_10_1016_j_mtbio_2025_101531
crossref_primary_10_1039_D3TB01469J
Cites_doi 10.1016/j.matlet.2021.129577
10.3389/fbioe.2021.772539
10.1186/s42490-022-00063-1
10.1177/09544119221075140
10.3389/fbioe.2022.938337
10.1007/s42235-018-0057-1
10.1016/j.arth.2008.07.014
10.1016/j.jmbbm.2017.08.034
10.3390/app12031548
10.3390/app12094197
10.1016/j.matdes.2018.04.002
10.3390/ma14237184
10.21823/2311-2905-2020-26-2-160-179
10.1016/j.medengphy.2020.05.003
10.1016/j.msec.2019.110289
10.1016/j.matdes.2022.110552
10.1016/j.jmbbm.2021.105059
10.1080/10255842.2022.2115291
10.1007/s42235-021-00103-x
10.31224/osf.io/qk7m3
10.1142/S0219519416400133
10.1590/0104-1428.02119
10.3390/math11020396
10.1166/jmihi.2013.1152
10.1177/1120700020949185
10.1016/j.mehy.2013.10.012
10.1016/j.jocd.2019.01.006
10.3389/fbioe.2022.850184
10.1016/j.jmbbm.2017.10.019
10.1111/aor.13444
10.1177/09544119211040998
10.1016/j.mechmachtheory.2022.105125
ContentType Journal Article
Copyright COPYRIGHT 2023 MDPI AG
2023 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.
2023 by the authors. 2023
Copyright_xml – notice: COPYRIGHT 2023 MDPI AG
– notice: 2023 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.
– notice: 2023 by the authors. 2023
DBID AAYXX
CITATION
NPM
7SR
8FD
8FE
8FG
ABJCF
ABUWG
AFKRA
AZQEC
BENPR
BGLVJ
CCPQU
D1I
DWQXO
HCIFZ
JG9
KB.
PDBOC
PHGZM
PHGZT
PIMPY
PKEHL
PQEST
PQGLB
PQQKQ
PQUKI
PRINS
7X8
5PM
DOI 10.3390/ma16083151
DatabaseName CrossRef
PubMed
Engineered Materials Abstracts
Technology Research Database
ProQuest SciTech Collection
ProQuest Technology Collection
Materials Science & Engineering Collection
ProQuest Central (Alumni)
ProQuest Central UK/Ireland
ProQuest Central Essentials
ProQuest Central
Technology collection
ProQuest One Community College
ProQuest Materials Science Collection
ProQuest Central
SciTech Premium
Materials Research Database
Materials Science Database
Materials Science Collection
ProQuest Central Premium
ProQuest One Academic
Publicly Available Content Database
ProQuest One Academic Middle East (New)
ProQuest One Academic Eastern Edition (DO NOT USE)
ProQuest One Applied & Life Sciences
ProQuest One Academic
ProQuest One Academic UKI Edition
ProQuest Central China
MEDLINE - Academic
PubMed Central (Full Participant titles)
DatabaseTitle CrossRef
PubMed
Publicly Available Content Database
Materials Research Database
Technology Collection
Technology Research Database
ProQuest One Academic Middle East (New)
ProQuest Central Essentials
Materials Science Collection
ProQuest Central (Alumni Edition)
SciTech Premium Collection
ProQuest One Community College
ProQuest Central China
ProQuest Central
ProQuest One Applied & Life Sciences
Engineered Materials Abstracts
ProQuest Central Korea
Materials Science Database
ProQuest Central (New)
ProQuest Materials Science Collection
ProQuest One Academic Eastern Edition
ProQuest Technology Collection
ProQuest SciTech Collection
ProQuest One Academic UKI Edition
Materials Science & Engineering Collection
ProQuest One Academic
ProQuest One Academic (New)
MEDLINE - Academic
DatabaseTitleList Publicly Available Content Database
PubMed

MEDLINE - Academic

CrossRef
Database_xml – sequence: 1
  dbid: NPM
  name: PubMed
  url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed
  sourceTypes: Index Database
– sequence: 2
  dbid: 8FG
  name: ProQuest Technology Collection
  url: https://search.proquest.com/technologycollection1
  sourceTypes: Aggregation Database
DeliveryMethod fulltext_linktorsrc
Discipline Engineering
EISSN 1996-1944
ExternalDocumentID PMC10143993
A747446222
37109987
10_3390_ma16083151
Genre Journal Article
GrantInformation_xml – fundername: Guangzhou City School Joint Project
  grantid: SL2023A03J00681
– fundername: University Scientific Research Project of Eduction Bureau of Guangzhou Municipality
  grantid: 202032821
GroupedDBID 29M
2WC
2XV
53G
5GY
5VS
8FE
8FG
AADQD
AAFWJ
AAHBH
AAYXX
ABDBF
ABJCF
ACUHS
ADBBV
ADMLS
AENEX
AFKRA
AFZYC
ALMA_UNASSIGNED_HOLDINGS
AOIJS
BCNDV
BENPR
BGLVJ
CCPQU
CITATION
CZ9
D1I
E3Z
EBS
ESX
FRP
GX1
HCIFZ
HH5
HYE
I-F
IAO
ITC
KB.
KC.
KQ8
MK~
MODMG
M~E
OK1
OVT
P2P
PDBOC
PGMZT
PHGZM
PHGZT
PIMPY
PROAC
RPM
TR2
TUS
GROUPED_DOAJ
NPM
PMFND
7SR
8FD
ABUWG
AZQEC
DWQXO
JG9
PKEHL
PQEST
PQGLB
PQQKQ
PQUKI
PRINS
7X8
PUEGO
5PM
ID FETCH-LOGICAL-c474t-17ed2c33a974e5b263c882049964f32456f430910684f1342872938aaca70863
IEDL.DBID BENPR
ISSN 1996-1944
IngestDate Thu Aug 21 18:37:40 EDT 2025
Fri Sep 05 07:34:28 EDT 2025
Fri Jul 25 12:04:44 EDT 2025
Tue Jun 17 20:59:46 EDT 2025
Tue Jun 10 20:38:26 EDT 2025
Wed Feb 19 02:24:46 EST 2025
Tue Jul 01 04:28:29 EDT 2025
Thu Apr 24 23:01:54 EDT 2025
IsDoiOpenAccess true
IsOpenAccess true
IsPeerReviewed true
IsScholarly true
Issue 8
Keywords topology optimization
multi-scale conditions
finite element analysis
stress shielding
femoral stem
Language English
License https://creativecommons.org/licenses/by/4.0
Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
LinkModel DirectLink
MergedId FETCHMERGED-LOGICAL-c474t-17ed2c33a974e5b263c882049964f32456f430910684f1342872938aaca70863
Notes ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
ORCID 0000-0002-0691-7755
OpenAccessLink https://www.proquest.com/docview/2806562016?pq-origsite=%requestingapplication%
PMID 37109987
PQID 2806562016
PQPubID 2032366
ParticipantIDs pubmedcentral_primary_oai_pubmedcentral_nih_gov_10143993
proquest_miscellaneous_2807923567
proquest_journals_2806562016
gale_infotracmisc_A747446222
gale_infotracacademiconefile_A747446222
pubmed_primary_37109987
crossref_citationtrail_10_3390_ma16083151
crossref_primary_10_3390_ma16083151
ProviderPackageCode CITATION
AAYXX
PublicationCentury 2000
PublicationDate 20230417
PublicationDateYYYYMMDD 2023-04-17
PublicationDate_xml – month: 4
  year: 2023
  text: 20230417
  day: 17
PublicationDecade 2020
PublicationPlace Switzerland
PublicationPlace_xml – name: Switzerland
– name: Basel
PublicationTitle Materials
PublicationTitleAlternate Materials (Basel)
PublicationYear 2023
Publisher MDPI AG
MDPI
Publisher_xml – name: MDPI AG
– name: MDPI
References Jette (ref_6) 2018; 77
Chen (ref_1) 2009; 24
Nandi (ref_22) 2022; 32
Xue (ref_35) 2022; 10
Zhang (ref_12) 2022; 19
ref_14
Shubnyakov (ref_3) 2020; 26
ref_10
ref_32
ref_30
Nomura (ref_34) 2022; 236
Chen (ref_18) 2020; 106
Wang (ref_23) 2016; 16
Wang (ref_11) 2020; 81
Domiciano (ref_25) 2019; 29
ref_19
Sun (ref_5) 2020; 15
Liu (ref_17) 2022; 9
Cheng (ref_33) 2022; 2022
Guo (ref_2) 2022; 216
Liang (ref_27) 2023; 180
Gao (ref_15) 2022; 10
Hazlehurst (ref_20) 2013; 81
Jette (ref_7) 2018; 77
Alkhatib (ref_8) 2019; 43
Gungorurler (ref_31) 2022; 236
(ref_4) 2020; 41
Maji (ref_26) 2013; 3
Messina (ref_21) 2020; 23
Mehboob (ref_13) 2018; 149
Hennicke (ref_28) 2022; 126
ref_29
Liu (ref_16) 2023; 38
ref_9
Avila (ref_24) 2021; 291
References_xml – volume: 291
  start-page: 129577
  year: 2021
  ident: ref_24
  article-title: Zirconia-toughened alumina coated Ti6Al4V via additive manufacturing
  publication-title: Mater. Lett.
  doi: 10.1016/j.matlet.2021.129577
– volume: 2022
  start-page: 4243476
  year: 2022
  ident: ref_33
  article-title: Topological optimization design for a multiscale femoral prosthesis model based on homogenization method
  publication-title: Sci. Program.
– volume: 9
  start-page: 772539
  year: 2022
  ident: ref_17
  article-title: Femoral stems with porous lattice structures: A review
  publication-title: Front. Bioeng. Biotech.
  doi: 10.3389/fbioe.2021.772539
– ident: ref_29
  doi: 10.1186/s42490-022-00063-1
– volume: 236
  start-page: 515
  year: 2022
  ident: ref_34
  article-title: Design optimization of functionally graded lattice infill total hip arthroplasty stem for stress shielding reduction
  publication-title: Proc. Inst. Mech. Eng. Part J. Eng. Med.
  doi: 10.1177/09544119221075140
– volume: 10
  start-page: 938337
  year: 2022
  ident: ref_35
  article-title: Novel design of the compound sleeve and stem prosthesis for treatment of proximal femur bone defects based on topology optimization
  publication-title: Front. Bioeng. Biotech.
  doi: 10.3389/fbioe.2022.938337
– volume: 15
  start-page: 693
  year: 2020
  ident: ref_5
  article-title: Biomechanical optimization of elastic modulus distribution in porous femoral stem for artificial hip joints
  publication-title: J. Bionic Eng.
  doi: 10.1007/s42235-018-0057-1
– volume: 24
  start-page: 945
  year: 2009
  ident: ref_1
  article-title: Bone remodeling characteristics of a short-stemmed total hip replacement
  publication-title: J. Arthroplast.
  doi: 10.1016/j.arth.2008.07.014
– volume: 77
  start-page: 58
  year: 2018
  ident: ref_6
  article-title: Femoral stem incorporating a diamond cubic lattice structure: Design, manufacturing and testing
  publication-title: J. Mech. Behav. Biomed.
  doi: 10.1016/j.jmbbm.2017.08.034
– ident: ref_9
  doi: 10.3390/app12031548
– ident: ref_10
  doi: 10.3390/app12094197
– volume: 149
  start-page: 101
  year: 2018
  ident: ref_13
  article-title: Finite element modelling and characterization of 3D cellular microstructures for the design of cementless biomimetic porous hip stem
  publication-title: Mater. Des.
  doi: 10.1016/j.matdes.2018.04.002
– ident: ref_32
  doi: 10.3390/ma14237184
– volume: 26
  start-page: 160
  year: 2020
  ident: ref_3
  article-title: Cementless hip implants: History and current status of the issue
  publication-title: Traumatol. Orthop. Russ.
  doi: 10.21823/2311-2905-2020-26-2-160-179
– volume: 81
  start-page: 30
  year: 2020
  ident: ref_11
  article-title: On the design and properties of porous femoral stems with adjustable stiffness gradient
  publication-title: Med. Eng. Phys.
  doi: 10.1016/j.medengphy.2020.05.003
– volume: 106
  start-page: 110289
  year: 2020
  ident: ref_18
  article-title: Influence of the pore size and porosity of selective laser melted Ti6Al4V ELI porous scaffold on cell proliferation osteogenesis and bone ingrowth
  publication-title: Mat. Sci. Eng. C Mater.
  doi: 10.1016/j.msec.2019.110289
– volume: 41
  start-page: 69
  year: 2020
  ident: ref_4
  article-title: Porous lattice structure of femoral stem for total hip arthroplasty
  publication-title: Rev. Mex. Ing. Biomed.
– volume: 216
  start-page: 110552
  year: 2022
  ident: ref_2
  article-title: On the design evolution of hip implants: A review
  publication-title: Mater. Des.
  doi: 10.1016/j.matdes.2022.110552
– volume: 126
  start-page: 105059
  year: 2022
  ident: ref_28
  article-title: Subject specific finite element modelling of periprosthetic femoral fractures in different load cases
  publication-title: J. Mech. Behav. Biomed.
  doi: 10.1016/j.jmbbm.2021.105059
– ident: ref_30
  doi: 10.1080/10255842.2022.2115291
– volume: 19
  start-page: 197
  year: 2022
  ident: ref_12
  article-title: Biomechanical effects of tibial stems with different structures on human knee joint after total knee arthroplasty: A finite element analysis
  publication-title: J. Bionic Eng.
  doi: 10.1007/s42235-021-00103-x
– ident: ref_14
  doi: 10.31224/osf.io/qk7m3
– volume: 16
  start-page: 1640013
  year: 2016
  ident: ref_23
  article-title: Optimization of femoral prosthesis based on comprehensive evaluation of structure and material properties
  publication-title: J. Mech. Med. Biol.
  doi: 10.1142/S0219519416400133
– volume: 29
  start-page: e2019057
  year: 2019
  ident: ref_25
  article-title: Design of a polymeric composite material femoral stem for hip joint implant
  publication-title: Polimeros
  doi: 10.1590/0104-1428.02119
– ident: ref_19
  doi: 10.3390/math11020396
– volume: 38
  start-page: 220
  year: 2023
  ident: ref_16
  article-title: Capability of auxetic femoral stems to reduce stress shielding after total hip arthroplasty
  publication-title: J. Orthop. Transl.
– volume: 3
  start-page: 171
  year: 2013
  ident: ref_26
  article-title: Minimizing stress shielding effect of femoral stem-a review
  publication-title: J. Med. Imaging Health Inform.
  doi: 10.1166/jmihi.2013.1152
– volume: 32
  start-page: 298
  year: 2022
  ident: ref_22
  article-title: Short-wedge stems have higher risk of periproshetic fracture than other cementless stem designs in Dorr type A femurs: A finite element analysis
  publication-title: Hip. Int.
  doi: 10.1177/1120700020949185
– volume: 81
  start-page: 1096
  year: 2013
  ident: ref_20
  article-title: The potential application of a cobalt chrome molybdenum femoral stem with functionally graded orthotropic structures manufactured using laser melting technologies
  publication-title: Med. Hypotheses
  doi: 10.1016/j.mehy.2013.10.012
– volume: 23
  start-page: 656
  year: 2020
  ident: ref_21
  article-title: Precision of Bone Mineral Density Measurements Around Total Ankle Replacement Using Dual Energy X-ray Absorptiometry
  publication-title: J. Clin. Densitom.
  doi: 10.1016/j.jocd.2019.01.006
– volume: 10
  start-page: 850184
  year: 2022
  ident: ref_15
  article-title: Parametric design of hip implant with gradient porous structure
  publication-title: Front. Bioeng. Biotech.
  doi: 10.3389/fbioe.2022.850184
– volume: 77
  start-page: 539
  year: 2018
  ident: ref_7
  article-title: Development and in vitro validation of a simplified numerical model for the design of a biomimetic femoral stem
  publication-title: J. Mech. Behav. Biomed.
  doi: 10.1016/j.jmbbm.2017.10.019
– volume: 43
  start-page: E152
  year: 2019
  ident: ref_8
  article-title: Finite element study of functionally graded porous femoral stems incorporating body-centered cubic structure
  publication-title: Artif. Organs.
  doi: 10.1111/aor.13444
– volume: 236
  start-page: 169
  year: 2022
  ident: ref_31
  article-title: Computational analysis of the effects of interprosthetic distance on normal and reduced cortical thickness femur models
  publication-title: Proc. Inst. Mech. Eng. Part J. Eng. Med.
  doi: 10.1177/09544119211040998
– volume: 180
  start-page: 105125
  year: 2023
  ident: ref_27
  article-title: Topology optimization of a spatial compliant parallel mechanism based on constant motion transmission characteristic matrix
  publication-title: Mech. Mach. Theory
  doi: 10.1016/j.mechmachtheory.2022.105125
SSID ssj0000331829
Score 2.3665128
Snippet Hip replacement femoral implants are made of substantial materials that all have stiffness considerably higher than that of bone, which can cause significant...
SourceID pubmedcentral
proquest
gale
pubmed
crossref
SourceType Open Access Repository
Aggregation Database
Index Database
Enrichment Source
StartPage 3151
SubjectTerms Biomedical materials
Compliance
Composite materials
Density
Design
Design optimization
Errors
Femoral components
Femur
Finite element method
Hip joint
Implants, Artificial
Isotropic material
Joint replacement surgery
Mechanical properties
Mechanical transmissions
Optimization
Orthopaedic implants
Prostheses
Prosthesis
Stiffness
Stress management
Stress shielding
Titanium alloys
Topology optimization
Transplants & implants
Variables
Title Multi-Scale Topology Optimization of Femoral Stem Structure Subject to Stress Shielding Reduce
URI https://www.ncbi.nlm.nih.gov/pubmed/37109987
https://www.proquest.com/docview/2806562016
https://www.proquest.com/docview/2807923567
https://pubmed.ncbi.nlm.nih.gov/PMC10143993
Volume 16
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwfV1LT9wwEB6V5QIH1AeloRS5KhLqwWKzfu6pohULqlRA7FbaUyOv44hKbMJjOfDvO5N4w6aqekw8iSx7PG9_A3BgvMzRR9NcoT7j0gwcd3nfcEMpL6scKg2Kd_w412c_5fepmsaA20Msq1zKxFpQ55WnGPlRnQHUqK70l9s7Tl2jKLsaW2iswTqKYKt6sP715Pzyqo2y9AXy7GDY4JIK9O-P5i7V1F1LpR1N9Lc8XlFI3WLJFe0zeglb0Wxkx80-v4IXoXwNmytggm_gV32Xlo9x0QObNL0PntgFioR5vGvJqoKNqLIW_zRehDkb1-Cxj_eBofyggAxbVPQSpR-jJtl1YopdEbpr2IbJ6GTy7YzH7gncSyMXPDUhH3ghHHoMQc0GWni0psnD0bIQlO8spCBrQVtZpIJcJ1T91jnvDPo54i30yqoM74DNKECihJqhdya1yq1Tw6HTOhQeDYy-TeDzciEzH5HFqcHFTYYeBi169rzoCXxqaW8bPI1_Uh3SfmR0yPBP3sW7AjgfgqvKjtEJQj8WbZsE9jqUeDh8d3i5o1k8nA_ZMysl8LEdpi-p4KwM1WNNQ8iKSpsEdhoGaOcrqH51aHHEdlijJSDI7u5I-fu6hu6mzshkEu7-f17vYYPa2lPWKjV70ENuCB_Q-FnM9mHNjk73I5_j0-k0_QOKAQQ6
linkProvider ProQuest
linkToHtml http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwtR3LbtQwcFTaA3BAvAkUMAKEOFjdxK_sAaECXW1pu6DuVuoJy-s4AolNCt0K9aP4R2by6gYhbr3GE8saz3vGMwAvjJcZ-miaK9RnXJrEcZcNDDeU8kqVQ6VB8Y6DiR4fyY_H6ngNfrdvYaisspWJlaDOSk8x8q0qA6hRXem3Jz84TY2i7Go7QqMmi71w_gtdttM3ux_wfl8myWhn9n7Mm6kC3Esjlzw2IUu8EA4t6aDmiRYerUyy_LXMBeUBcylIi-pU5rEglwJVYuqcdwbtf4HbXoENtDKGyEQb73Ymnw-7oM5AIIskw7oNqhDDwdbCxZqGeam4p_j-Fv8r-q9fm7mi7EY34UZjpbLtmqxuwVoobsP1ld6Fd-BL9XSXT_GOA5vVoxbO2SeUQIvmaScrczaiQl7caboMCzatetWe_QwMxRXFf9iypI8obBnN5K7yYOyQmsmGuzC7DLTeg_WiLMIDYHOKxyih5ugMSq2y1CGqndYh92jPDNIIXreItL5pZE7zNL5bdGgI6fYC6RE872BP6vYd_4R6RfdhiadxJ--apwl4HuqOZbfR50K3GU2pCDZ7kMiLvr_c3qhtZMGpvaDcCJ51y_Qn1bcVoTyrYKiRo9Imgvs1AXTnFVQuO0xxJe2RRgdAHcL7K8W3r1WncBrETBbow_-f6ylcHc8O9u3-7mTvEVxD_AtKmMVmE9aRMsJjtLuW8ycNtTOwl8xffwCJdDsS
linkToPdf http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwtR1da9RAcKhXEH2Q-h1bdUVFfFh6yX4lDyLV9mitnqV3hT4Z9jYbFLyktldKf5r_zpl89SLiW1-zk2WZne-ZnQF4ZZzM0EfTXKE-49JElttsaLihlFesLCoNind8GevdI_npWB2vwO_2LQyVVbYysRLUWekoRr5ZZQB1RLVZeVMWcbA9en_yi9MEKcq0tuM0ahLZ95cX6L6dvdvbxrt-HUWjnenHXd5MGOBOGrngofFZ5ISwaFV7NYu0cGhxkhegZS4oJ5hLQRpVxzIPBbkXqB5ja5016AsI3PYGrBpUivEAVj_sjA8OuwDPUCC7REndElWIZLg5t6GmwV4q7CnBv1XBki7s12kuKb7RGtxpLFa2VZPYXVjxxT24vdTH8D58q57x8gnet2fTeuzCJfuK0mjePPNkZc5GVNSLO00Wfs4mVd_a81PPUHRRLIgtSvqIgpfRfO4qJ8YOqbGsfwDT60DrQxgUZeEfA5tRbEYJNUPHUGqVxVYlidXa5w5tm2EcwNsWkalrmprTbI2fKTo3hPT0CukBvOxgT-pWHv-EekP3kRJ_407ONs8U8DzUKSvdQv8LXWg0qwLY6EEiX7r-cnujaSMXztIrKg7gRbdMf1KtW-HL8wqGmjoqbQJ4VBNAd15BpbNJjCtxjzQ6AOoW3l8pfnyvuobTUGayRp_8_1zP4SbyVfp5b7y_DrcQ_YJyZ6HZgAEShn-KJthi9qwhdgbpNbPXHzlvPz4
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Multi-Scale+Topology+Optimization+of+Femoral+Stem+Structure+Subject+to+Stress+Shielding+Reduce&rft.jtitle=Materials&rft.au=Xiao%2C+Zhongmin&rft.au=Wu%2C+Longfei&rft.au=Wu%2C+Wenqiang&rft.au=Tang%2C+Ruizhi&rft.date=2023-04-17&rft.pub=MDPI+AG&rft.issn=1996-1944&rft.eissn=1996-1944&rft.volume=16&rft.issue=8&rft_id=info:doi/10.3390%2Fma16083151&rft.externalDocID=A747446222
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1996-1944&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1996-1944&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1996-1944&client=summon