Immediate effects of breath holding maneuvers onto composition of exhaled breath
Rapid concentration changes due to physiological or pathophysiological effects rather than appearance of unique disease biomarkers are important for clinical application of breath research. Simple maneuvers such as breath holding may significantly affect breath biomarker concentrations. In this stud...
Saved in:
Published in | Journal of breath research Vol. 8; no. 3; pp. 37102 - 37111 |
---|---|
Main Authors | , , , |
Format | Journal Article |
Language | English |
Published |
England
IOP Publishing
01.09.2014
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Abstract | Rapid concentration changes due to physiological or pathophysiological effects rather than appearance of unique disease biomarkers are important for clinical application of breath research. Simple maneuvers such as breath holding may significantly affect breath biomarker concentrations. In this study, exhaled volatile organic compound (VOC) concentrations were assessed in real time before and after different breath holding maneuvers. Continuous breath-resolved measurements (PTR-ToF-MS-8000) were performed in 31 healthy human subjects in a side-stream sampling mode. After 1 min of tidal breathing participants held their breath for 10, 20, 40, 60 s and as long as possible. Afterwards they continued to breathe normally for another minute. VOC profiles could be monitored in real time by assigning online PTR-ToF-MS data to alveolar or inspired phases of breath. Sudden and profound changes of exhaled VOC concentrations were recorded after different breath holding maneuvers. VOC concentrations returned to base line levels 10-20 s after breath holding. Breath holding induced concentration changes depended on physico-chemical properties of the substances. When substance concentrations were normalized onto end-tidal CO2 content, variation of acetone concentrations decreased, whereas variations of isoprene concentrations were not affected. As the effects of breathing patterns on exhaled substance concentrations depend on individual substance properties, sampling procedures have to be validated for each compound by means of appropriate real-time analysis. Normalization of exhaled concentrations onto exhaled CO2 is only valid for substances having similar physico-chemical properties as CO2. |
---|---|
AbstractList | Rapid concentration changes due to physiological or pathophysiological effects rather than appearance of unique disease biomarkers are important for clinical application of breath research. Simple maneuvers such as breath holding may significantly affect breath biomarker concentrations. In this study, exhaled volatile organic compound (VOC) concentrations were assessed in real time before and after different breath holding maneuvers. Continuous breath-resolved measurements (PTR-ToF-MS-8000) were performed in 31 healthy human subjects in a side-stream sampling mode. After 1 min of tidal breathing participants held their breath for 10, 20, 40, 60 s and as long as possible. Afterwards they continued to breathe normally for another minute. VOC profiles could be monitored in real time by assigning online PTR-ToF-MS data to alveolar or inspired phases of breath. Sudden and profound changes of exhaled VOC concentrations were recorded after different breath holding maneuvers. VOC concentrations returned to base line levels 10-20 s after breath holding. Breath holding induced concentration changes depended on physico-chemical properties of the substances. When substance concentrations were normalized onto end-tidal CO2 content, variation of acetone concentrations decreased, whereas variations of isoprene concentrations were not affected. As the effects of breathing patterns on exhaled substance concentrations depend on individual substance properties, sampling procedures have to be validated for each compound by means of appropriate real-time analysis. Normalization of exhaled concentrations onto exhaled CO2 is only valid for substances having similar physico-chemical properties as CO2.Rapid concentration changes due to physiological or pathophysiological effects rather than appearance of unique disease biomarkers are important for clinical application of breath research. Simple maneuvers such as breath holding may significantly affect breath biomarker concentrations. In this study, exhaled volatile organic compound (VOC) concentrations were assessed in real time before and after different breath holding maneuvers. Continuous breath-resolved measurements (PTR-ToF-MS-8000) were performed in 31 healthy human subjects in a side-stream sampling mode. After 1 min of tidal breathing participants held their breath for 10, 20, 40, 60 s and as long as possible. Afterwards they continued to breathe normally for another minute. VOC profiles could be monitored in real time by assigning online PTR-ToF-MS data to alveolar or inspired phases of breath. Sudden and profound changes of exhaled VOC concentrations were recorded after different breath holding maneuvers. VOC concentrations returned to base line levels 10-20 s after breath holding. Breath holding induced concentration changes depended on physico-chemical properties of the substances. When substance concentrations were normalized onto end-tidal CO2 content, variation of acetone concentrations decreased, whereas variations of isoprene concentrations were not affected. As the effects of breathing patterns on exhaled substance concentrations depend on individual substance properties, sampling procedures have to be validated for each compound by means of appropriate real-time analysis. Normalization of exhaled concentrations onto exhaled CO2 is only valid for substances having similar physico-chemical properties as CO2. Rapid concentration changes due to physiological or pathophysiological effects rather than appearance of unique disease biomarkers are important for clinical application of breath research. Simple maneuvers such as breath holding may significantly affect breath biomarker concentrations. In this study, exhaled volatile organic compound (VOC) concentrations were assessed in real time before and after different breath holding maneuvers. Continuous breath-resolved measurements (PTR-ToF-MS-8000) were performed in 31 healthy human subjects in a side-stream sampling mode. After 1 min of tidal breathing participants held their breath for 10, 20, 40, 60 s and as long as possible. Afterwards they continued to breathe normally for another minute. VOC profiles could be monitored in real time by assigning online PTR-ToF-MS data to alveolar or inspired phases of breath. Sudden and profound changes of exhaled VOC concentrations were recorded after different breath holding maneuvers. VOC concentrations returned to base line levels 10-20 s after breath holding. Breath holding induced concentration changes depended on physico-chemical properties of the substances. When substance concentrations were normalized onto end-tidal CO2 content, variation of acetone concentrations decreased, whereas variations of isoprene concentrations were not affected. As the effects of breathing patterns on exhaled substance concentrations depend on individual substance properties, sampling procedures have to be validated for each compound by means of appropriate real-time analysis. Normalization of exhaled concentrations onto exhaled CO2 is only valid for substances having similar physico-chemical properties as CO2. Rapid concentration changes due to physiological or pathophysiological effects rather than appearance of unique disease biomarkers are important for clinical application of breath research. Simple maneuvers such as breath holding may significantly affect breath biomarker concentrations. In this study, exhaled volatile organic compound (VOC) concentrations were assessed in real time before and after different breath holding maneuvers. Continuous breath-resolved measurements (PTR-ToF-MS-8000) were performed in 31 healthy human subjects in a side-stream sampling mode. After 1 min of tidal breathing participants held their breath for 10, 20, 40, 60 s and as long as possible. Afterwards they continued to breathe normally for another minute. VOC profiles could be monitored in real time by assigning online PTR-ToF-MS data to alveolar or inspired phases of breath. Sudden and profound changes of exhaled VOC concentrations were recorded after different breath holding maneuvers. VOC concentrations returned to base line levels 10-20 s after breath holding. Breath holding induced concentration changes depended on physico-chemical properties of the substances. When substance concentrations were normalized onto end-tidal CO2 content, variation of acetone concentrations decreased, whereas variations of isoprene concentrations were not affected. As the effects of breathing patterns on exhaled substance concentrations depend on individual substance properties, sampling procedures have to be validated for each compound by means of appropriate real-time analysis. Normalization of exhaled concentrations onto exhaled CO2 is only valid for substances having similar physico-chemical properties as CO2. |
Author | Schubert, Jochen K Miekisch, Wolfram Trefz, Phillip Sukul, Pritam |
Author_xml | – sequence: 1 givenname: Pritam surname: Sukul fullname: Sukul, Pritam organization: Department of Anaesthesiology and Intensive Care, Rostock Medical Breath Research Analytics and Technologies (ROMBAT), University Medicine Rostock , Schillingallee 35, D-18057 Rostock, Germany – sequence: 2 givenname: Phillip surname: Trefz fullname: Trefz, Phillip organization: Department of Anaesthesiology and Intensive Care, Rostock Medical Breath Research Analytics and Technologies (ROMBAT), University Medicine Rostock , Schillingallee 35, D-18057 Rostock, Germany – sequence: 3 givenname: Jochen K surname: Schubert fullname: Schubert, Jochen K organization: Department of Anaesthesiology and Intensive Care, Rostock Medical Breath Research Analytics and Technologies (ROMBAT), University Medicine Rostock , Schillingallee 35, D-18057 Rostock, Germany – sequence: 4 givenname: Wolfram surname: Miekisch fullname: Miekisch, Wolfram email: wolfram.miekisch@uni-rostock.de organization: Department of Anaesthesiology and Intensive Care, Rostock Medical Breath Research Analytics and Technologies (ROMBAT), University Medicine Rostock , Schillingallee 35, D-18057 Rostock, Germany |
BackLink | https://www.ncbi.nlm.nih.gov/pubmed/25189647$$D View this record in MEDLINE/PubMed |
BookMark | eNqFkV1LwzAUhoMoOqf_QKQgiDdzSZMmqXcifgwGeqHXIU0Tl9E2NUlF_70t21RE2FVC8jyHl_ccgt3GNRqAEwQvEeR8iliWThjKsimf4inEDMF0B4zWzxTvft-z7AAchrCEkBLI831wkGaI55SwEXia1bUurYw60cZoFUPiTFJ4LeMiWbiqtM1rUstGd-_a939NdIlydeuCjdY1A6w_FrLS5Vo6AntGVkEfr88xeLm7fb55mMwf72c31_OJIgzHCcoJLEtCpSwJJySnSnFkMgVpWUjC0oISwxFnFBtDUyUVREihXLOCYlVwjMfgYjW39e6t0yGK2galq6rP6rogUEZTklKOYY-e_UGXrvNNn06kDGNIGeekp07XVFf0lYjW21r6T7HpqgeuVoDyLgSvjVA2yqGF6KWtBIJiWIwYWhdD64ILLFaL6WXyR97M36LBlWZd-5N6i3L-j7Is_C9ItKXBX-ZFqnk |
CODEN | JBROBW |
CitedBy_id | crossref_primary_10_1183_13993003_00009_2022 crossref_primary_10_1088_1752_7163_aad384 crossref_primary_10_1021_acssensors_1c01808 crossref_primary_10_1038_s41598_022_22581_7 crossref_primary_10_1016_j_trac_2024_117977 crossref_primary_10_1002_oby_21242 crossref_primary_10_1007_s11306_017_1241_8 crossref_primary_10_1088_1752_7163_aa7d10 crossref_primary_10_1088_1752_7163_ab7e3b crossref_primary_10_1088_1752_7163_aa8a46 crossref_primary_10_1088_1752_7163_ad15a3 crossref_primary_10_1039_C9AN01478K crossref_primary_10_1088_1752_7163_ab1789 crossref_primary_10_1038_s42003_023_05384_y crossref_primary_10_1016_j_cca_2021_12_019 crossref_primary_10_1136_thoraxjnl_2015_207597 crossref_primary_10_1088_1752_7163_aa8d86 crossref_primary_10_1088_1752_7155_9_4_047105 crossref_primary_10_1373_clinchem_2016_256909 crossref_primary_10_1038_s41598_020_70993_0 crossref_primary_10_34133_bmef_0002 crossref_primary_10_3390_jcm8111797 crossref_primary_10_1088_1752_7163_abba6c crossref_primary_10_1038_s43856_024_00723_4 crossref_primary_10_1088_1752_7155_10_4_046007 crossref_primary_10_1088_1752_7155_9_3_036002 crossref_primary_10_1007_s00216_019_01764_8 crossref_primary_10_1016_j_materresbull_2024_112915 crossref_primary_10_1088_1752_7155_8_3_030201 crossref_primary_10_1088_1752_7163_aa61bf crossref_primary_10_1088_1752_7163_aa6368 crossref_primary_10_3390_molecules25245823 crossref_primary_10_1016_j_isci_2022_103739 crossref_primary_10_1016_j_aca_2018_01_069 crossref_primary_10_1111_ina_12602 crossref_primary_10_1016_j_matchemphys_2025_130381 crossref_primary_10_1038_s41598_022_10325_6 crossref_primary_10_1183_13993003_00965_2016 crossref_primary_10_1088_1752_7163_acaf98 crossref_primary_10_1007_s11306_024_02104_3 crossref_primary_10_1088_1752_7163_aabdaf crossref_primary_10_1016_j_saa_2024_124625 crossref_primary_10_1016_j_isci_2022_105195 crossref_primary_10_1088_1752_7163_aa7174 crossref_primary_10_1016_j_microc_2025_113073 crossref_primary_10_1038_srep28029 crossref_primary_10_1038_s41598_018_29221_z crossref_primary_10_1038_s41598_018_35854_x crossref_primary_10_1088_1752_7163_ab28ec crossref_primary_10_1016_j_mehy_2022_110837 crossref_primary_10_1088_1752_7163_aa927d crossref_primary_10_1088_1752_7163_aa9eea crossref_primary_10_1016_j_pacs_2024_100604 crossref_primary_10_1088_1752_7163_aa94e7 crossref_primary_10_1109_TAFFC_2023_3275216 crossref_primary_10_1021_acs_analchem_4c02214 crossref_primary_10_3390_metabo11040192 crossref_primary_10_3390_molecules25133098 crossref_primary_10_1088_1752_7163_abbf39 crossref_primary_10_1088_1752_7163_ab55c5 crossref_primary_10_2139_ssrn_4055638 crossref_primary_10_3389_fphys_2022_946401 crossref_primary_10_1007_s11306_018_1405_1 crossref_primary_10_1088_1752_7163_acec08 crossref_primary_10_1134_S1061934824701430 |
Cites_doi | 10.1021/ac020725g 10.1016/j.cca.2008.04.021 10.1088/0967-3334/31/9/008 10.1186/1471-2466-13-43 10.1021/ac801185e 10.1021/ac3031465 10.1289/ehp.97105636 10.3390/s91008230 10.1021/ac071898e 10.1007/s00216-011-5173-2 10.1002/bmc.1141 10.1007/s00216-010-3524-z 10.1186/1471-2407-9-348 10.1093/bja/aeg271 10.1073/pnas.68.10.2374 10.1088/1752-7155/7/1/017112 10.1088/1752-7155/7/1/017110 10.1088/1752-7155/6/1/016005 10.1021/ac960749l 10.1088/1752-7155/5/1/016001 10.1021/ac100061k 10.1088/1752-7155/5/4/046008 10.1021/ac060053k 10.1002/ijc.24970 10.1088/1752-7155/6/3/036007 10.1007/s00216-011-5099-8 10.1016/j.cccn.2004.04.023 10.1007/s00285-010-0398-9 10.1021/ac9027593 10.1021/ac3029097 10.1371/journal.pone.0059658 10.3109/13693786.2010.508187 10.1088/1752-7155/3/2/027006 10.1002/mas.20303 10.1021/ac051194+ 10.1021/ac402298v 10.1111/j.1748-1716.2006.01624.x |
ContentType | Journal Article |
Copyright | 2014 IOP Publishing Ltd |
Copyright_xml | – notice: 2014 IOP Publishing Ltd |
DBID | AAYXX CITATION CGR CUY CVF ECM EIF NPM K9. 7X8 |
DOI | 10.1088/1752-7155/8/3/037102 |
DatabaseName | CrossRef Medline MEDLINE MEDLINE (Ovid) MEDLINE MEDLINE PubMed ProQuest Health & Medical Complete (Alumni) MEDLINE - Academic |
DatabaseTitle | CrossRef MEDLINE Medline Complete MEDLINE with Full Text PubMed MEDLINE (Ovid) ProQuest Health & Medical Complete (Alumni) MEDLINE - Academic |
DatabaseTitleList | MEDLINE - Academic MEDLINE ProQuest Health & Medical Complete (Alumni) |
Database_xml | – sequence: 1 dbid: NPM name: PubMed url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed sourceTypes: Index Database – sequence: 2 dbid: EIF name: MEDLINE url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search sourceTypes: Index Database |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Anatomy & Physiology |
DocumentTitleAlternate | Immediate effects of breath holding maneuvers onto composition of exhaled breath |
EISSN | 1752-7163 |
ExternalDocumentID | 25189647 10_1088_1752_7155_8_3_037102 jbr494241 |
Genre | Research Support, Non-U.S. Gov't Journal Article |
GroupedDBID | --- 1JI 4.4 53G 5B3 5GY 5VS 7.M AAGCD AAJIO AALHV AATNI ABJNI ABLJU ABVAM ACAFW ACGFS ACHIP AEFHF AENEX AFYNE AKPSB ALMA_UNASSIGNED_HOLDINGS AOAED ASPBG ATQHT AVWKF AZFZN CEBXE CJUJL CRLBU CS3 EBS EDWGO EJD EQZZN F5P IJHAN IOP IZVLO JCGBZ KOT LAP M45 MV1 N5L N9A NT- NT. PJBAE RIN RNS ROL RPA SY9 W28 AAYXX ADEQX AERVB CITATION 02O 1WK AHSEE BBWZM CGR CUY CVF ECM EIF FEDTE HVGLF NPM Q02 K9. 7X8 |
ID | FETCH-LOGICAL-c473t-1940dd46aad484496cc81f5c06dba472b64f818763ff62cac011c19e7b63cb833 |
IEDL.DBID | IOP |
ISSN | 1752-7155 1752-7163 |
IngestDate | Fri Jul 11 02:40:16 EDT 2025 Mon Jun 30 05:22:19 EDT 2025 Mon Jul 21 05:40:00 EDT 2025 Tue Jul 01 04:26:59 EDT 2025 Thu Apr 24 23:20:39 EDT 2025 Wed Aug 21 03:34:06 EDT 2024 Thu Jan 07 13:49:57 EST 2021 |
IsPeerReviewed | true |
IsScholarly | true |
Issue | 3 |
Language | English |
License | http://iopscience.iop.org/info/page/text-and-data-mining http://iopscience.iop.org/page/copyright |
LinkModel | DirectLink |
MergedId | FETCHMERGED-LOGICAL-c473t-1940dd46aad484496cc81f5c06dba472b64f818763ff62cac011c19e7b63cb833 |
Notes | JBR-100053.R2 ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 14 content type line 23 |
PMID | 25189647 |
PQID | 2733067884 |
PQPubID | 6326151 |
PageCount | 10 |
ParticipantIDs | pubmed_primary_25189647 iop_journals_10_1088_1752_7155_8_3_037102 proquest_miscellaneous_1562426830 crossref_citationtrail_10_1088_1752_7155_8_3_037102 crossref_primary_10_1088_1752_7155_8_3_037102 proquest_journals_2733067884 |
ProviderPackageCode | CITATION AAYXX |
PublicationCentury | 2000 |
PublicationDate | 2014-09-01 |
PublicationDateYYYYMMDD | 2014-09-01 |
PublicationDate_xml | – month: 09 year: 2014 text: 2014-09-01 day: 01 |
PublicationDecade | 2010 |
PublicationPlace | England |
PublicationPlace_xml | – name: England – name: Bristol |
PublicationTitle | Journal of breath research |
PublicationTitleAbbrev | JBR |
PublicationTitleAlternate | J. Breath Res |
PublicationYear | 2014 |
Publisher | IOP Publishing |
Publisher_xml | – name: IOP Publishing |
References | 22 44 23 Pleil J D (2) 2013; 7 24 25 26 28 Ulanowska A (43) 2011; 5 Thekedar B (40) 2011; 5 King J (32) 2012; 6 Pleil J D (20) 2011; 5 Amann A (42) 2011; 11 Herbig J (33) 2009; 3 Miekisch W (41) 2012; 6 King J (29) 2009; 3 King J (30) 2010; 31 31 10 White I R (35) 2013; 7 11 12 13 36 15 37 16 38 17 39 18 Kohl I (34) 2013; 7 19 Pleil J D (21) 2011; 5 Fuchs P (14) 2010; 126 1 3 4 Schwarz K (27) 2009; 3 6 7 8 9 Mukhopadhyay R (5) 2004; 76 |
References_xml | – volume: 7 issn: 1752-7163 year: 2013 ident: 2 publication-title: J. Breath Res. – ident: 9 doi: 10.1021/ac020725g – volume: 11 start-page: 207 year: 2011 ident: 42 publication-title: ERM Diagn. – ident: 18 doi: 10.1016/j.cca.2008.04.021 – volume: 31 start-page: 1169 issn: 0967-3334 year: 2010 ident: 30 publication-title: Physiol. Meas. doi: 10.1088/0967-3334/31/9/008 – ident: 38 doi: 10.1186/1471-2466-13-43 – ident: 23 doi: 10.1021/ac801185e – ident: 11 doi: 10.1021/ac3031465 – ident: 3 doi: 10.1289/ehp.97105636 – ident: 26 doi: 10.3390/s91008230 – ident: 7 doi: 10.1021/ac071898e – ident: 28 doi: 10.1007/s00216-011-5173-2 – ident: 17 doi: 10.1002/bmc.1141 – ident: 16 doi: 10.1007/s00216-010-3524-z – volume: 3 issn: 1752-7163 year: 2009 ident: 33 publication-title: J. Breath Res. – ident: 44 doi: 10.1186/1471-2407-9-348 – ident: 4 doi: 10.1093/bja/aeg271 – ident: 1 doi: 10.1073/pnas.68.10.2374 – volume: 7 issn: 1752-7163 year: 2013 ident: 35 publication-title: J. Breath Res. doi: 10.1088/1752-7155/7/1/017112 – volume: 7 issn: 1752-7163 year: 2013 ident: 34 publication-title: J. Breath Res. doi: 10.1088/1752-7155/7/1/017110 – volume: 6 issn: 1752-7163 year: 2012 ident: 32 publication-title: J. Breath Res. doi: 10.1088/1752-7155/6/1/016005 – ident: 8 doi: 10.1021/ac960749l – volume: 5 issn: 1752-7163 year: 2011 ident: 40 publication-title: J. Breath Res. doi: 10.1088/1752-7155/5/1/016001 – ident: 12 doi: 10.1021/ac100061k – volume: 5 issn: 1752-7163 year: 2011 ident: 43 publication-title: J. Breath Res. doi: 10.1088/1752-7155/5/4/046008 – ident: 10 doi: 10.1021/ac060053k – volume: 126 start-page: 2663 year: 2010 ident: 14 publication-title: Int. J. Cancer doi: 10.1002/ijc.24970 – volume: 6 issn: 1752-7163 year: 2012 ident: 41 publication-title: J. Breath Res. doi: 10.1088/1752-7155/6/3/036007 – ident: 19 doi: 10.1007/s00216-011-5099-8 – volume: 76 start-page: 273A–6A year: 2004 ident: 5 publication-title: Anal. Chem. – ident: 15 doi: 10.1016/j.cccn.2004.04.023 – ident: 31 doi: 10.1007/s00285-010-0398-9 – ident: 6 doi: 10.1021/ac9027593 – ident: 22 doi: 10.1021/ac3029097 – volume: 3 issn: 1752-7163 year: 2009 ident: 27 publication-title: J. Breath Res. – ident: 36 doi: 10.1371/journal.pone.0059658 – ident: 13 doi: 10.3109/13693786.2010.508187 – volume: 3 issn: 1752-7163 year: 2009 ident: 29 publication-title: J. Breath Res. doi: 10.1088/1752-7155/3/2/027006 – volume: 5 issn: 1752-7163 year: 2011 ident: 20 publication-title: J. Breath Res. – volume: 5 issn: 1752-7163 year: 2011 ident: 21 publication-title: J. Breath Res. – ident: 25 doi: 10.1002/mas.20303 – ident: 24 doi: 10.1021/ac051194+ – ident: 37 doi: 10.1021/ac402298v – ident: 39 doi: 10.1111/j.1748-1716.2006.01624.x |
SSID | ssj0064089 |
Score | 2.2810788 |
Snippet | Rapid concentration changes due to physiological or pathophysiological effects rather than appearance of unique disease biomarkers are important for clinical... |
SourceID | proquest pubmed crossref iop |
SourceType | Aggregation Database Index Database Enrichment Source Publisher |
StartPage | 37102 |
SubjectTerms | Adult Biomarkers Biomarkers - analysis breath biomarkers Breath Holding Breath tests Breath Tests - methods Carbon Dioxide - metabolism Computer Systems Exhalation Female Humans Male normalization physiological effects real-time VOC analysis Time Factors VOCs Volatile organic compounds Volatile Organic Compounds - analysis Young Adult |
Title | Immediate effects of breath holding maneuvers onto composition of exhaled breath |
URI | https://iopscience.iop.org/article/10.1088/1752-7155/8/3/037102 https://www.ncbi.nlm.nih.gov/pubmed/25189647 https://www.proquest.com/docview/2733067884 https://www.proquest.com/docview/1562426830 |
Volume | 8 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwpV1LSwMxEA5aL158P6pVI4jgYdttk2bTo4iigo-Dgre4eSFqt0W3oP56Z3az9QEi4i2QySaZZDJfNvMgZMe3Net4uKY6weKI-64HkepBiRkreCqE9uicfHYujq_56U33JuQ5LXxhBsNw9DehWAYKLlkYDOJkCxQegELQgy3ZYi0MOYfBJKeYBOWJHnwXl9VRLHhc5MAbt6h85374yhfdNAn9_ww7C_VzNEtuq4GXVicPzVGum-btW0zHf8xsjswEaEr3S_J5MuGyBbK4n8G1vP9Kd2lhLFr8hV8klyf9wuckdzRYhNCBpxoR6B0NL1q0n2ZuhGYfFIMkULReDyZiSOxe7kA52dBoiVwfHV4dHEchOUNkeMLyqN3jsbVcpKnlkvOeMEa2fdfEwuqUJx0tuAcwAMeX96JjUgMHiWn3XKIFM1oytkxq2SBzq4RalxiXeOEYNxzwWYre-VZ3UgCPUMfrhFXLokyIXI4JNB5V8YIupULGKWSckoqpknF1Eo1bDcvIHb_Q78G6qCDCz7_Qbn2hvddPn2rV0Po6aVQ754MMoCLe0KSEKW2Pq0Ge8ZEGlmQwgm676LEjJIvrZKXccePhAxaV6Dm89oehrpNpwHi8NItrkFr-NHIbgKNyvVnIyjvRgA1H |
linkProvider | IOP Publishing |
linkToPdf | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwpV1LT9wwEB4BlRCXvnhtS4uREBKHbLKx43iPiHbFo4U9gMTNil9atWx2RbNS21_fceKEUgmhilskj5Pxa-ZzPN8YYN8NFE0dblMtp0nEXOZwSQ3xiWrDWcG5cp6c_PWCn1yzs5vsZgmOOy7MbB5Mfx8fm0TBTReGgDgRo8NDUIh-MBYxjX3KuSSN58Ytw4uMov_0LL7LcWuOOUvqe_C6Wi1_7pE3PfBPy6jD49CzdkGjV2Ba5ZvIk-_9RaX6-vc_eR2f2brX8DJAVHLUVHkDS7Z8C-tHJW7Pp7_IAamDRuu_8eswPp3W3JPKkhAZQmaOKI9EJyScbJFpUdqFD_8gPlkC8VHsIVTMC9ufE3RSJlTagOvR56vjkyhc0hBpltMqGgxZYgzjRWGYYGzItRYDl-mEG1WwPFWcOQQFaMac46kuNBoUPRjaXHGqlaB0E1bKWWm3gRiba5s7binTDHFa4Vn6RqUFgkgsYz2g7dBIHTKY-4s0bmV9ki6E9J0nfedJIalsOq8HUVdr3mTweEL-EMdGhqX84wnZ3Qey39TdX6USh60HO-3suRdDyOh3akJgk_a6YlzX_rAGh2S2wM9mnrnDBU16sNXMuk59xKTCM4jf_Yequ7A6_jSSX04vzt_DGsI-1kTK7cBKdbewHxBaVepjvXT-AHG2Eqs |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Immediate+effects+of+breath+holding+maneuvers+onto+composition+of+exhaled+breath&rft.jtitle=Journal+of+breath+research&rft.au=Sukul%2C+Pritam&rft.au=Trefz%2C+Phillip&rft.au=Schubert%2C+Jochen+K&rft.au=Miekisch%2C+Wolfram&rft.date=2014-09-01&rft.pub=IOP+Publishing&rft.issn=1752-7155&rft.eissn=1752-7163&rft.volume=8&rft.issue=3&rft_id=info:doi/10.1088%2F1752-7155%2F8%2F3%2F037102&rft.externalDocID=jbr494241 |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1752-7155&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1752-7155&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1752-7155&client=summon |