Asymmetrical Vertical Phorias in Normal Subjects: The Influence of Unbalanced Illumination

Purpose: One goal of this investigation was to determine whether asymmetrical vertical hetereophorias, which are qualitatively similar to a dissociated vertical deviation (DVD), occur commonly in normal people. A second goal was to establish whether the magnitude or direction of vertical phoria depe...

Full description

Saved in:
Bibliographic Details
Published inStrabismus Vol. 13; no. 3; pp. 123 - 128
Main Authors Wang, Minhua, Bedell, Harold E.
Format Journal Article
LanguageEnglish
Published England Informa UK Ltd 01.01.2005
Taylor & Francis
Subjects
Online AccessGet full text

Cover

Loading…
Abstract Purpose: One goal of this investigation was to determine whether asymmetrical vertical hetereophorias, which are qualitatively similar to a dissociated vertical deviation (DVD), occur commonly in normal people. A second goal was to establish whether the magnitude or direction of vertical phoria depends on the illumination of the occluded eye, as would be expected if vertical eye position were influenced by a dorsal light reflex. Methods: Vertical phorias were estimated in 30 normal subjects using a Maddox rod in conjunction with a dark and an illuminated occluder. Results: On average, subjects exhibited a hypophoria of less than 1 min arc with both the dark and the illuminated occluder. Asymmetrical vertical phorias that were consistent with previously published criteria for a minute DVD were found in eight subjects when a dark occluder was used and in four subjects when an illuminated occluder was used. The proportions of subjects whose vertical phorias were consistent with a DVD did not differ significantly under the two conditions of occlusion. Conclusions: Asymmetrical vertical phorias that mimic a minute DVD do not occur commonly in normal people. Our finding that vertical phorias do not change systematically when an illuminated instead of a dark occluder is used suggests that normal subjects exhibit little or no vestige of the dorsal light reflex.
AbstractList One goal of this investigation was to determine whether asymmetrical vertical hetereophorias, which are qualitatively similar to a dissociated vertical deviation (DVD), occur commonly in normal people. A second goal was to establish whether the magnitude or direction of vertical phoria depends on the illumination of the occluded eye, as would be expected if vertical eye position were influenced by a dorsal light reflex. Vertical phorias were estimated in 30 normal subjects using a Maddox rod in conjunction with a dark and an illuminated occluder. On average, subjects exhibited a hypophoria of less than 1 min arc with both the dark and the illuminated occluder. Asymmetrical vertical phorias that were consistent with previously published criteria for a minute DVD were found in eight subjects when a dark occluder was used and in four subjects when an illuminated occluder was used. The proportions of subjects whose vertical phorias were consistent with a DVD did not differ significantly under the two conditions of occlusion. Asymmetrical vertical phorias that mimic a minute DVD do not occur commonly in normal people. Our finding that vertical phorias do not change systematically when an illuminated instead of a dark occluder is used suggests that normal subjects exhibit little or no vestige of the dorsal light reflex.
Purpose: One goal of this investigation was to determine whether asymmetrical vertical hetereophorias, which are qualitatively similar to a dissociated vertical deviation (DVD), occur commonly in normal people. A second goal was to establish whether the magnitude or direction of vertical phoria depends on the illumination of the occluded eye, as would be expected if vertical eye position were influenced by a dorsal light reflex. Methods: Vertical phorias were estimated in 30 normal subjects using a Maddox rod in conjunction with a dark and an illuminated occluder. Results: On average, subjects exhibited a hypophoria of less than 1 min arc with both the dark and the illuminated occluder. Asymmetrical vertical phorias that were consistent with previously published criteria for a minute DVD were found in eight subjects when a dark occluder was used and in four subjects when an illuminated occluder was used. The proportions of subjects whose vertical phorias were consistent with a DVD did not differ significantly under the two conditions of occlusion. Conclusions: Asymmetrical vertical phorias that mimic a minute DVD do not occur commonly in normal people. Our finding that vertical phorias do not change systematically when an illuminated instead of a dark occluder is used suggests that normal subjects exhibit little or no vestige of the dorsal light reflex.
One goal of this investigation was to determine whether asymmetrical vertical hetereophorias, which are qualitatively similar to a dissociated vertical deviation (DVD), occur commonly in normal people. A second goal was to establish whether the magnitude or direction of vertical phoria depends on the illumination of the occluded eye, as would be expected if vertical eye position were influenced by a dorsal light reflex.PURPOSEOne goal of this investigation was to determine whether asymmetrical vertical hetereophorias, which are qualitatively similar to a dissociated vertical deviation (DVD), occur commonly in normal people. A second goal was to establish whether the magnitude or direction of vertical phoria depends on the illumination of the occluded eye, as would be expected if vertical eye position were influenced by a dorsal light reflex.Vertical phorias were estimated in 30 normal subjects using a Maddox rod in conjunction with a dark and an illuminated occluder.METHODSVertical phorias were estimated in 30 normal subjects using a Maddox rod in conjunction with a dark and an illuminated occluder.On average, subjects exhibited a hypophoria of less than 1 min arc with both the dark and the illuminated occluder. Asymmetrical vertical phorias that were consistent with previously published criteria for a minute DVD were found in eight subjects when a dark occluder was used and in four subjects when an illuminated occluder was used. The proportions of subjects whose vertical phorias were consistent with a DVD did not differ significantly under the two conditions of occlusion.RESULTSOn average, subjects exhibited a hypophoria of less than 1 min arc with both the dark and the illuminated occluder. Asymmetrical vertical phorias that were consistent with previously published criteria for a minute DVD were found in eight subjects when a dark occluder was used and in four subjects when an illuminated occluder was used. The proportions of subjects whose vertical phorias were consistent with a DVD did not differ significantly under the two conditions of occlusion.Asymmetrical vertical phorias that mimic a minute DVD do not occur commonly in normal people. Our finding that vertical phorias do not change systematically when an illuminated instead of a dark occluder is used suggests that normal subjects exhibit little or no vestige of the dorsal light reflex.CONCLUSIONSAsymmetrical vertical phorias that mimic a minute DVD do not occur commonly in normal people. Our finding that vertical phorias do not change systematically when an illuminated instead of a dark occluder is used suggests that normal subjects exhibit little or no vestige of the dorsal light reflex.
Author Wang, Minhua
Bedell, Harold E.
Author_xml – sequence: 1
  givenname: Minhua
  surname: Wang
  fullname: Wang, Minhua
  organization: 1College of Optometry, University of Houston, Houston, Texas, USA
– sequence: 2
  givenname: Harold E.
  surname: Bedell
  fullname: Bedell, Harold E.
  organization: 1College of Optometry, University of Houston, Houston, Texas, USA
BackLink https://www.ncbi.nlm.nih.gov/pubmed/16251141$$D View this record in MEDLINE/PubMed
BookMark eNp9kMtu1DAUQC1URKeFD2CDsmIX8HXiOANsqorHSBWtRMuCjWU7NxqPHLvYjqr5ezydItQizcqvc-zknJAjHzwS8hroO6A9fU-XTDRLQTmlDLq248_IAkTb1hwadkQWu_O6AOyYnKS0oRR6YOIFOYaOcYAWFuTXWdpOE-ZojXLVT4z5fnK1DtGqVFlffQ9xKjs_Zr1Bk9OH6nqN1cqPbkZvsApjdeO1cqoshmrl3DxZr7IN_iV5PiqX8NXDeEpuvny-Pv9WX1x-XZ2fXdSmFTTXeqC06fi47BtskKEBbMXABVPaDFwLTY3QAkWnda8oIOsMANcILUex7LE5JW_3997G8HvGlOVkk0FXPgnDnGTXi6bntCvgmwdw1hMO8jbaScWt_FujALAHTAwpRRz_IVTuisv_ihdHPHGMzff_n6Oy7qD5aW9aP-4a34XoBpnV1oU4xtLTJtkc0j8-0teoXF4bFVFuwhx9SX7g8T8R2qkk
CitedBy_id crossref_primary_10_1038_s41598_020_72646_8
crossref_primary_10_1080_09273970600896877
crossref_primary_10_1007_s10384_011_0043_1
crossref_primary_10_1080_09273970600896927
Cites_doi 10.1097/00006324-194009000-00023
10.1067/mpa.2000.107896
10.1016/S0042-6989(02)00047-0
10.1001/archopht.1941.00870110032003
10.1136/bjo.38.10.591
10.1016/S0042-6989(98)00079-0
10.1097/00004397-197101140-00014
10.1016/S1091-8531(00)70002-4
10.1001/archopht.1932.00820120089005
10.3928/0191-3913-19961101-07
10.1001/archopht.1953.00920020322009
10.1016/S0002-9394(31)91154-9
10.1001/archopht.117.9.1216
10.1001/archopht.120.9.1174
ContentType Journal Article
Copyright 2005 Informa UK Ltd All rights reserved: reproduction in whole or part not permitted 2005
Copyright_xml – notice: 2005 Informa UK Ltd All rights reserved: reproduction in whole or part not permitted 2005
DBID AAYXX
CITATION
CGR
CUY
CVF
ECM
EIF
NPM
7X8
DOI 10.1080/09273970500216465
DatabaseName CrossRef
Medline
MEDLINE
MEDLINE (Ovid)
MEDLINE
MEDLINE
PubMed
MEDLINE - Academic
DatabaseTitle CrossRef
MEDLINE
Medline Complete
MEDLINE with Full Text
PubMed
MEDLINE (Ovid)
MEDLINE - Academic
DatabaseTitleList MEDLINE

MEDLINE - Academic

Database_xml – sequence: 1
  dbid: NPM
  name: PubMed
  url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed
  sourceTypes: Index Database
– sequence: 2
  dbid: EIF
  name: MEDLINE
  url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search
  sourceTypes: Index Database
DeliveryMethod fulltext_linktorsrc
Discipline Medicine
EISSN 1744-5132
EndPage 128
ExternalDocumentID 16251141
10_1080_09273970500216465
121629
Genre Research Article
Research Support, U.S. Gov't, P.H.S
Journal Article
Research Support, N.I.H., Extramural
GrantInformation_xml – fundername: NEI NIH HHS
  grantid: P30 EY 07551
– fundername: NEI NIH HHS
  grantid: R01 EY 05068
GroupedDBID ---
00X
03L
0BK
0R~
123
29Q
36B
4.4
53G
5VS
AAJNR
AALIY
AALUX
AAMIU
AAPUL
AAPXX
AAQRR
ABBKH
ABDBF
ABEIZ
ABLKL
ABOCM
ABPTK
ABUPF
ABWCV
ABZEW
ACENM
ACFUF
ACGEJ
ACGFS
ACKZS
ACLSK
ADCVX
ADFCX
ADFOM
ADFZZ
ADRBQ
ADXPE
AECIN
AEIIZ
AEOZL
AEYQI
AFKVX
AFLEI
AFWLO
AGDLA
AGFJD
AGRBW
AGYJP
AIJEM
AIRBT
AJVHN
AJWEG
AKBVH
ALIIL
ALMA_UNASSIGNED_HOLDINGS
ALQZU
AMDAE
AWYRJ
BABNJ
BLEHA
BOHLJ
BRMBE
CAG
CCCUG
COF
CS3
CYYVM
CZDIS
DKSSO
DRXRE
DWTOO
EAP
EBC
EBD
EBS
EJD
EMB
EMK
EMOBN
EPL
ESX
F5P
H13
HZ~
J.N
JENTW
KRBQP
KWAYT
KYCEM
LJTGL
M44
M4Z
O9-
QQXMO
RNANH
RVRKI
SV3
TFDNU
TFL
TFW
TUS
UEQFS
V1S
~1N
ABJNI
ABLIJ
ABXYU
ACIEZ
ACUHS
ALYBC
TBQAZ
TDBHL
TERGH
TUROJ
AAGDL
AAORF
AAYXX
ABWVI
ACOPL
ACYZI
ADYSH
AFRVT
AMPGV
CITATION
NUSFT
CGR
CUY
CVF
ECM
EIF
NPM
7X8
ID FETCH-LOGICAL-c470t-bd00365f983e3e2ec1e47d572abcd5b7b0c7b7e76bb8a01e26c115be145e798e3
ISSN 0927-3972
IngestDate Thu Jul 10 20:55:08 EDT 2025
Wed Feb 19 01:42:56 EST 2025
Thu Apr 24 23:03:36 EDT 2025
Tue Jul 01 02:32:29 EDT 2025
Wed Dec 25 09:03:38 EST 2024
Wed Jun 21 01:49:08 EDT 2023
IsPeerReviewed true
IsScholarly true
Issue 3
Language English
LinkModel OpenURL
MergedId FETCHMERGED-LOGICAL-c470t-bd00365f983e3e2ec1e47d572abcd5b7b0c7b7e76bb8a01e26c115be145e798e3
Notes ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
PMID 16251141
PQID 68738506
PQPubID 23479
PageCount 6
ParticipantIDs crossref_primary_10_1080_09273970500216465
crossref_citationtrail_10_1080_09273970500216465
proquest_miscellaneous_68738506
informahealthcare_journals_10_1080_09273970500216465
pubmed_primary_16251141
informaworld_taylorfrancis_310_1080_09273970500216465
ProviderPackageCode CITATION
AAYXX
PublicationCentury 2000
PublicationDate 2005-01-01
PublicationDateYYYYMMDD 2005-01-01
PublicationDate_xml – month: 01
  year: 2005
  text: 2005-01-01
  day: 01
PublicationDecade 2000
PublicationPlace England
PublicationPlace_xml – name: England
PublicationTitle Strabismus
PublicationTitleAlternate Strabismus
PublicationYear 2005
Publisher Informa UK Ltd
Taylor & Francis
Publisher_xml – name: Informa UK Ltd
– name: Taylor & Francis
References Goltz H C (CIT0008) 1996; 33
Guyton D L (CIT0010) 1998; 96
Brodsky M C (CIT0005) 2002; 120
Ogle K N (CIT0015) 1953; 49
Frisby J P (CIT0007) 1980; 37
Verhoeff F H (CIT0018) 1941; 25
Scobee R G (CIT0016) 1952
Brodsky M C (CIT0004) 1999; 117
Von Noorden G K (CIT0019) 1972; 76
Graf E W (CIT0009) 2002; 42
Guyton D L (CIT0011) 2000; 4
White J W (CIT0020) 1932; 7
Abraham S V (CIT0001) 1931; 14
CIT0003
Lang J (CIT0014) 2000; 4
CIT0002
Lang J (CIT0013) 1972; 11
Van Rijn L J (CIT0017) 1998; 38
Crone R A (CIT0006) 1954; 38
Helveston E M (CIT0012) 1980; 78
16950747 - Strabismus. 2006 Sep;14(3):169-70; author reply 171-4
References_xml – ident: CIT0003
  doi: 10.1097/00006324-194009000-00023
– volume: 4
  start-page: 254
  year: 2000
  ident: CIT0014
  publication-title: J AAPOS.
  doi: 10.1067/mpa.2000.107896
– volume: 42
  start-page: 1185
  year: 2002
  ident: CIT0009
  publication-title: Vision Res.
  doi: 10.1016/S0042-6989(02)00047-0
– volume: 25
  start-page: 780
  year: 1941
  ident: CIT0018
  publication-title: Arch Ophthalmol.
  doi: 10.1001/archopht.1941.00870110032003
– volume: 38
  start-page: 591
  year: 1954
  ident: CIT0006
  publication-title: Br J Ophthalmol.
  doi: 10.1136/bjo.38.10.591
– volume: 78
  start-page: 734
  year: 1980
  ident: CIT0012
  publication-title: Trans Am Ophthalmol Soc.
– volume: 38
  start-page: 2973
  year: 1998
  ident: CIT0017
  publication-title: Vision Res.
  doi: 10.1016/S0042-6989(98)00079-0
– volume: 11
  start-page: 88
  year: 1972
  ident: CIT0013
  publication-title: Int Ophthalmol Clin.
  doi: 10.1097/00004397-197101140-00014
– volume: 4
  start-page: 131
  year: 2000
  ident: CIT0011
  publication-title: J AAPOS.
  doi: 10.1016/S1091-8531(00)70002-4
– volume-title: The Oculorotary Muscles, 2nd edition
  year: 1952
  ident: CIT0016
– volume: 37
  start-page: 108
  year: 1980
  ident: CIT0007
  publication-title: Br Orthopt J.
– volume: 7
  start-page: 739
  year: 1932
  ident: CIT0020
  publication-title: Arch Ophthalmol.
  doi: 10.1001/archopht.1932.00820120089005
– volume: 33
  start-page: 307
  year: 1996
  ident: CIT0008
  publication-title: J Pediatr Ophthalmol Strabismus.
  doi: 10.3928/0191-3913-19961101-07
– volume: 49
  start-page: 313
  year: 1953
  ident: CIT0015
  publication-title: Arch Ophthalmol.
  doi: 10.1001/archopht.1953.00920020322009
– ident: CIT0002
– volume: 14
  start-page: 657
  year: 1931
  ident: CIT0001
  publication-title: Am J Ophthalmol.
  doi: 10.1016/S0002-9394(31)91154-9
– volume: 96
  start-page: 389
  year: 1998
  ident: CIT0010
  publication-title: Trans Am Ophthalmol Soc.
– volume: 117
  start-page: 1216
  year: 1999
  ident: CIT0004
  publication-title: Arch Ophthalmol.
  doi: 10.1001/archopht.117.9.1216
– volume: 120
  start-page: 1174
  year: 2002
  ident: CIT0005
  publication-title: Arch Ophthalmol.
  doi: 10.1001/archopht.120.9.1174
– volume: 76
  start-page: 1465
  year: 1972
  ident: CIT0019
  publication-title: Trans Am Acad Ophthalmol Otolaryngol.
– reference: 16950747 - Strabismus. 2006 Sep;14(3):169-70; author reply 171-4
SSID ssj0018127
Score 1.6394709
Snippet Purpose: One goal of this investigation was to determine whether asymmetrical vertical hetereophorias, which are qualitatively similar to a dissociated...
One goal of this investigation was to determine whether asymmetrical vertical hetereophorias, which are qualitatively similar to a dissociated vertical...
SourceID proquest
pubmed
crossref
informaworld
informahealthcare
SourceType Aggregation Database
Index Database
Enrichment Source
Publisher
StartPage 123
SubjectTerms Adult
dissociated vertical deviation
dorsal light reflex
Heterophoria
Humans
Lighting
Middle Aged
Reference Values
Strabismus - physiopathology
Title Asymmetrical Vertical Phorias in Normal Subjects: The Influence of Unbalanced Illumination
URI https://www.tandfonline.com/doi/abs/10.1080/09273970500216465
https://www.ncbi.nlm.nih.gov/pubmed/16251141
https://www.proquest.com/docview/68738506
Volume 13
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1Lj5swELbarFT1Um3f6dOHnloRAbYx9JZtd5VtlVUPm3bVC8LGKJE2pCrk0P76zoB5hO1G7V4QQhgD38cwM54HIW-YZsCEFKRfCiKQwz_JUSLijszCVAZaKKMwG3l-FswW_NOFuOjapVbZJaWa6N9_zSu5CapwDHDFLNn_QLa9KByAfcAXtoAwbP8J42nxa73Gllj4or9WEdKw82W5gbmrONcz1EgvUTqgu6VoQixOm84kqCoucoXhjRgHcIptj1d5B5bVWrGErVoV622rgH-zbub5Kl9uO5vepHYZY4ZxJOm748mOV0EMvApNLtTicy-6qPIa-iCTorrbzsTUMlNy7giP7QpV1iMP60lIr04vtj9br84MvyLHbeAjzAaTuQI1kYDXTSUG5bG9psbp8Nzb5MAH08EfkYPp0cejk3ZtCVSaKom-eZRmrRsrrg8vsqOtHNpatss2Mm9Q3_Z6K6XSVs4PyT1rZtBpzZn75JbJH5A7cxtI8ZB871OHNtShljp0ldOaOrShznsKxKEtcegmox1xaJ84j8ji5Pj8w8yxbTYczaVbOirFokQii0JmmPGN9gyXqZB-onQqlFSulkoaGSgVJq5n_ECDGaGMx4WRUWjYYzLKN7l5SmjkGeNrXG3XCWfSi7JASR3pKMtEkho-Jm7zOmNta9BjK5TL-FoYx-RtO-RHXYBl38n8Ckax_WCLfcNEH8a4rJxlWd3ZJmZ7xr1u8I5BKuNSW5KbzbaIgxCrRLnBmDypadDde4BGPfee3exWn5O73ef6gozKn1vzEtTiUr2yPP8Dr22txg
linkProvider EBSCOhost
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Asymmetrical+Vertical+Phorias+in+Normal+Subjects%3A+The+Influence+of+Unbalanced+Illumination&rft.jtitle=Strabismus&rft.au=Wang%2C+Minhua&rft.au=Bedell%2C+Harold+E.&rft.date=2005-01-01&rft.pub=Informa+UK+Ltd&rft.issn=0927-3972&rft.eissn=1744-5132&rft.volume=13&rft.issue=3&rft.spage=123&rft.epage=128&rft_id=info:doi/10.1080%2F09273970500216465&rft.externalDocID=10_1080_09273970500216465
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0927-3972&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0927-3972&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0927-3972&client=summon