Biomechanics and finite element analysis comparing posterior T-plates with LCP for fixation of posterolateral tibial plate fractures
Objective: The treatment for posterolateral tibial plateau fractures (PTPF) have been subjects of controversy. We conducted a study to improve the fixation of PTPF through a lateral approach. Methods: We utilized 40 synthetic tibias and categorized the fracture models into five groups based on the l...
Saved in:
Published in | Frontiers in bioengineering and biotechnology Vol. 11; p. 1286993 |
---|---|
Main Authors | , , , , , , , , |
Format | Journal Article |
Language | English |
Published |
Switzerland
Frontiers Media S.A
07.12.2023
|
Subjects | |
Online Access | Get full text |
ISSN | 2296-4185 2296-4185 |
DOI | 10.3389/fbioe.2023.1286993 |
Cover
Loading…
Abstract | Objective:
The treatment for posterolateral tibial plateau fractures (PTPF) have been subjects of controversy. We conducted a study to improve the fixation of PTPF through a lateral approach.
Methods:
We utilized 40 synthetic tibias and categorized the fracture models into five groups based on the locking compression plate (LCP) and T-distal radius plate (TPP) via various forms of fixation with screws through the posterolateral (PL) fracture fragments. I: Two-screw fixation using two locking screws (LPTL). Ⅱ: Two-screw fixation with both variable angle locking screws (LPTV). Ⅲ: One-screw fixation with one locking screw (LPOL). Ⅳ: One-screw fixation with one locking screw and two anteroposterior lag screws (LPOLTL). Ⅴ: a distal radius plate with three locking screws (TPP). Biomechanical tests were conducted to observe the axial compression displacement of the PL fracture fragments at force levels of 250 N, 500 N, and 750 N, as well as to determine the failure load and the axial stiffness for each respective group.
Results:
Under a 750 N load condition, the displacements within the five experimental groups exhibited the following trend: Ⅴ < Ⅱ < Ⅰ< Ⅳ < Ⅲ. However, there were no significant differences between Group V and Group II, Group I and Group IV (
p
> 0.05), and only Group Ⅲ demonstrated a displacement exceeding 3 mm. The failure load and the axial stiffness exhibited the same trend. Conversely, statistical significance was identified among the remaining group compared with Group Ⅲ (
p
< 0.05). Regarding the finite element analysis, the maximum displacements for the five models under the load of 750 N exhibited the following trend: Ⅴ < Ⅱ < Ⅰ< Ⅳ < Ⅲ. The following trends were observed in maximum von Mises stresses for these models under the load of 750 N: Ⅴ < Ⅱ < Ⅳ< Ⅰ < Ⅲ.
Conclusion:
It is crucial to address the inadequate mechanical strength associated with single screw fixation of LCP for fixing PL fractures in a clinical setting. The biomechanical strength of two-screw fixation surpasses that of single-screw fixation. Introducing variable-angle screws can further enhance the fixation range. Furthermore, the addition of two lag screws threaded from anterior to posterior can compensate the mechanical stability, when PL fracture is fixed with single screw in clinic. |
---|---|
AbstractList | Objective:
The treatment for posterolateral tibial plateau fractures (PTPF) have been subjects of controversy. We conducted a study to improve the fixation of PTPF through a lateral approach.
Methods:
We utilized 40 synthetic tibias and categorized the fracture models into five groups based on the locking compression plate (LCP) and T-distal radius plate (TPP) via various forms of fixation with screws through the posterolateral (PL) fracture fragments. I: Two-screw fixation using two locking screws (LPTL). Ⅱ: Two-screw fixation with both variable angle locking screws (LPTV). Ⅲ: One-screw fixation with one locking screw (LPOL). Ⅳ: One-screw fixation with one locking screw and two anteroposterior lag screws (LPOLTL). Ⅴ: a distal radius plate with three locking screws (TPP). Biomechanical tests were conducted to observe the axial compression displacement of the PL fracture fragments at force levels of 250 N, 500 N, and 750 N, as well as to determine the failure load and the axial stiffness for each respective group.
Results:
Under a 750 N load condition, the displacements within the five experimental groups exhibited the following trend: Ⅴ < Ⅱ < Ⅰ< Ⅳ < Ⅲ. However, there were no significant differences between Group V and Group II, Group I and Group IV (
p
> 0.05), and only Group Ⅲ demonstrated a displacement exceeding 3 mm. The failure load and the axial stiffness exhibited the same trend. Conversely, statistical significance was identified among the remaining group compared with Group Ⅲ (
p
< 0.05). Regarding the finite element analysis, the maximum displacements for the five models under the load of 750 N exhibited the following trend: Ⅴ < Ⅱ < Ⅰ< Ⅳ < Ⅲ. The following trends were observed in maximum von Mises stresses for these models under the load of 750 N: Ⅴ < Ⅱ < Ⅳ< Ⅰ < Ⅲ.
Conclusion:
It is crucial to address the inadequate mechanical strength associated with single screw fixation of LCP for fixing PL fractures in a clinical setting. The biomechanical strength of two-screw fixation surpasses that of single-screw fixation. Introducing variable-angle screws can further enhance the fixation range. Furthermore, the addition of two lag screws threaded from anterior to posterior can compensate the mechanical stability, when PL fracture is fixed with single screw in clinic. Objective: The treatment for posterolateral tibial plateau fractures (PTPF) have been subjects of controversy. We conducted a study to improve the fixation of PTPF through a lateral approach. Methods: We utilized 40 synthetic tibias and categorized the fracture models into five groups based on the locking compression plate (LCP) and T-distal radius plate (TPP) via various forms of fixation with screws through the posterolateral (PL) fracture fragments. I: Two-screw fixation using two locking screws (LPTL). Ⅱ: Two-screw fixation with both variable angle locking screws (LPTV). Ⅲ: One-screw fixation with one locking screw (LPOL). Ⅳ: One-screw fixation with one locking screw and two anteroposterior lag screws (LPOLTL). Ⅴ: a distal radius plate with three locking screws (TPP). Biomechanical tests were conducted to observe the axial compression displacement of the PL fracture fragments at force levels of 250 N, 500 N, and 750 N, as well as to determine the failure load and the axial stiffness for each respective group. Results: Under a 750 N load condition, the displacements within the five experimental groups exhibited the following trend: Ⅴ < Ⅱ < Ⅰ< Ⅳ < Ⅲ. However, there were no significant differences between Group V and Group II, Group I and Group IV (p > 0.05), and only Group Ⅲ demonstrated a displacement exceeding 3 mm. The failure load and the axial stiffness exhibited the same trend. Conversely, statistical significance was identified among the remaining group compared with Group Ⅲ (p < 0.05). Regarding the finite element analysis, the maximum displacements for the five models under the load of 750 N exhibited the following trend: Ⅴ < Ⅱ < Ⅰ< Ⅳ < Ⅲ. The following trends were observed in maximum von Mises stresses for these models under the load of 750 N: Ⅴ < Ⅱ < Ⅳ< Ⅰ < Ⅲ. Conclusion: It is crucial to address the inadequate mechanical strength associated with single screw fixation of LCP for fixing PL fractures in a clinical setting. The biomechanical strength of two-screw fixation surpasses that of single-screw fixation. Introducing variable-angle screws can further enhance the fixation range. Furthermore, the addition of two lag screws threaded from anterior to posterior can compensate the mechanical stability, when PL fracture is fixed with single screw in clinic.Objective: The treatment for posterolateral tibial plateau fractures (PTPF) have been subjects of controversy. We conducted a study to improve the fixation of PTPF through a lateral approach. Methods: We utilized 40 synthetic tibias and categorized the fracture models into five groups based on the locking compression plate (LCP) and T-distal radius plate (TPP) via various forms of fixation with screws through the posterolateral (PL) fracture fragments. I: Two-screw fixation using two locking screws (LPTL). Ⅱ: Two-screw fixation with both variable angle locking screws (LPTV). Ⅲ: One-screw fixation with one locking screw (LPOL). Ⅳ: One-screw fixation with one locking screw and two anteroposterior lag screws (LPOLTL). Ⅴ: a distal radius plate with three locking screws (TPP). Biomechanical tests were conducted to observe the axial compression displacement of the PL fracture fragments at force levels of 250 N, 500 N, and 750 N, as well as to determine the failure load and the axial stiffness for each respective group. Results: Under a 750 N load condition, the displacements within the five experimental groups exhibited the following trend: Ⅴ < Ⅱ < Ⅰ< Ⅳ < Ⅲ. However, there were no significant differences between Group V and Group II, Group I and Group IV (p > 0.05), and only Group Ⅲ demonstrated a displacement exceeding 3 mm. The failure load and the axial stiffness exhibited the same trend. Conversely, statistical significance was identified among the remaining group compared with Group Ⅲ (p < 0.05). Regarding the finite element analysis, the maximum displacements for the five models under the load of 750 N exhibited the following trend: Ⅴ < Ⅱ < Ⅰ< Ⅳ < Ⅲ. The following trends were observed in maximum von Mises stresses for these models under the load of 750 N: Ⅴ < Ⅱ < Ⅳ< Ⅰ < Ⅲ. Conclusion: It is crucial to address the inadequate mechanical strength associated with single screw fixation of LCP for fixing PL fractures in a clinical setting. The biomechanical strength of two-screw fixation surpasses that of single-screw fixation. Introducing variable-angle screws can further enhance the fixation range. Furthermore, the addition of two lag screws threaded from anterior to posterior can compensate the mechanical stability, when PL fracture is fixed with single screw in clinic. The treatment for posterolateral tibial plateau fractures (PTPF) have been subjects of controversy. We conducted a study to improve the fixation of PTPF through a lateral approach. We utilized 40 synthetic tibias and categorized the fracture models into five groups based on the locking compression plate (LCP) and T-distal radius plate (TPP) via various forms of fixation with screws through the posterolateral (PL) fracture fragments. I: Two-screw fixation using two locking screws (LPTL). Ⅱ: Two-screw fixation with both variable angle locking screws (LPTV). Ⅲ: One-screw fixation with one locking screw (LPOL). Ⅳ: One-screw fixation with one locking screw and two anteroposterior lag screws (LPOLTL). Ⅴ: a distal radius plate with three locking screws (TPP). Biomechanical tests were conducted to observe the axial compression displacement of the PL fracture fragments at force levels of 250 N, 500 N, and 750 N, as well as to determine the failure load and the axial stiffness for each respective group. Under a 750 N load condition, the displacements within the five experimental groups exhibited the following trend: Ⅴ < Ⅱ < Ⅰ< Ⅳ < Ⅲ. However, there were no significant differences between Group V and Group II, Group I and Group IV ( > 0.05), and only Group Ⅲ demonstrated a displacement exceeding 3 mm. The failure load and the axial stiffness exhibited the same trend. Conversely, statistical significance was identified among the remaining group compared with Group Ⅲ ( < 0.05). Regarding the finite element analysis, the maximum displacements for the five models under the load of 750 N exhibited the following trend: Ⅴ < Ⅱ < Ⅰ< Ⅳ < Ⅲ. The following trends were observed in maximum von Mises stresses for these models under the load of 750 N: Ⅴ < Ⅱ < Ⅳ< Ⅰ < Ⅲ. It is crucial to address the inadequate mechanical strength associated with single screw fixation of LCP for fixing PL fractures in a clinical setting. The biomechanical strength of two-screw fixation surpasses that of single-screw fixation. Introducing variable-angle screws can further enhance the fixation range. Furthermore, the addition of two lag screws threaded from anterior to posterior can compensate the mechanical stability, when PL fracture is fixed with single screw in clinic. Objective: The treatment for posterolateral tibial plateau fractures (PTPF) have been subjects of controversy. We conducted a study to improve the fixation of PTPF through a lateral approach.Methods: We utilized 40 synthetic tibias and categorized the fracture models into five groups based on the locking compression plate (LCP) and T-distal radius plate (TPP) via various forms of fixation with screws through the posterolateral (PL) fracture fragments. I: Two-screw fixation using two locking screws (LPTL). Ⅱ: Two-screw fixation with both variable angle locking screws (LPTV). Ⅲ: One-screw fixation with one locking screw (LPOL). Ⅳ: One-screw fixation with one locking screw and two anteroposterior lag screws (LPOLTL). Ⅴ: a distal radius plate with three locking screws (TPP). Biomechanical tests were conducted to observe the axial compression displacement of the PL fracture fragments at force levels of 250 N, 500 N, and 750 N, as well as to determine the failure load and the axial stiffness for each respective group.Results: Under a 750 N load condition, the displacements within the five experimental groups exhibited the following trend: Ⅴ < Ⅱ < Ⅰ< Ⅳ < Ⅲ. However, there were no significant differences between Group V and Group II, Group I and Group IV (p > 0.05), and only Group Ⅲ demonstrated a displacement exceeding 3 mm. The failure load and the axial stiffness exhibited the same trend. Conversely, statistical significance was identified among the remaining group compared with Group Ⅲ (p < 0.05). Regarding the finite element analysis, the maximum displacements for the five models under the load of 750 N exhibited the following trend: Ⅴ < Ⅱ < Ⅰ< Ⅳ < Ⅲ. The following trends were observed in maximum von Mises stresses for these models under the load of 750 N: Ⅴ < Ⅱ < Ⅳ< Ⅰ < Ⅲ.Conclusion: It is crucial to address the inadequate mechanical strength associated with single screw fixation of LCP for fixing PL fractures in a clinical setting. The biomechanical strength of two-screw fixation surpasses that of single-screw fixation. Introducing variable-angle screws can further enhance the fixation range. Furthermore, the addition of two lag screws threaded from anterior to posterior can compensate the mechanical stability, when PL fracture is fixed with single screw in clinic. |
Author | Wu, Chenying Li, Liubing Gu, Zenghui Ren, Weizhi Zhang, Wen Xu, Wei Hu, Zhenghui Wu, Weicheng Peng, Jian |
AuthorAffiliation | 1 Department of Orthopedics , The Second Affiliated Hospital of Soochow University , Suzhou , China 2 Orthopedic Institute of Soochow University , Suzhou , China |
AuthorAffiliation_xml | – name: 1 Department of Orthopedics , The Second Affiliated Hospital of Soochow University , Suzhou , China – name: 2 Orthopedic Institute of Soochow University , Suzhou , China |
Author_xml | – sequence: 1 givenname: Zhenghui surname: Hu fullname: Hu, Zhenghui – sequence: 2 givenname: Weizhi surname: Ren fullname: Ren, Weizhi – sequence: 3 givenname: Jian surname: Peng fullname: Peng, Jian – sequence: 4 givenname: Zenghui surname: Gu fullname: Gu, Zenghui – sequence: 5 givenname: Chenying surname: Wu fullname: Wu, Chenying – sequence: 6 givenname: Weicheng surname: Wu fullname: Wu, Weicheng – sequence: 7 givenname: Wen surname: Zhang fullname: Zhang, Wen – sequence: 8 givenname: Wei surname: Xu fullname: Xu, Wei – sequence: 9 givenname: Liubing surname: Li fullname: Li, Liubing |
BackLink | https://www.ncbi.nlm.nih.gov/pubmed/38130819$$D View this record in MEDLINE/PubMed |
BookMark | eNp9Uktv1DAQjlARLaV_gAPykUsWP-LEPiFY8ai0EhzK2Zr4sesqiYPtBXrnh-PsblHLgdNYM99D4_meV2dTmGxVvSR4xZiQb1zvg11RTNmKUNFKyZ5UF5TKtm6I4GcP3ufVVUq3GGNCeccFfVadM0EYFkReVL_f-zBavYPJ64RgMsj5yWeL7GBHO-XSguEu-YR0GGeIftqiOaRsow8R3dTzANkm9NPnHdqsvyJXus7_guzDhII7YcOCijCg7HtfyoGFXASd99GmF9VTB0OyV6d6WX37-OFm_bnefPl0vX63qXXTylxz0A2TTnNHuOgM6WkHBPe97EzTEwGcE9MDpi0jwuGOW9s4Q40m0EiGG8Euq-ujrglwq-boR4h3KoBXh0aIWwUxez1YRZwGJnjPSdM2sgNwLW4pFsZQS3jTFq23R61534_W6PJXZcFHoo8nk9-pbfihCO4Y43hReH1SiOH73qasRp-0HQaYbNgnRSUuG_FOLtBXD83-utzfsQDEEaBjSClap7TPhyMUbz8UU7WkRh1So5bUqFNqCpX-Q71X_w_pD44dyRg |
CitedBy_id | crossref_primary_10_1111_os_14358 |
Cites_doi | 10.1016/j.gaitpost.2014.04.205 10.3389/fbioe.2023.1150541 10.1016/j.injury.2020.07.059 10.1016/j.medengphy.2011.05.012 10.1016/j.injury.2016.06.001 10.1016/j.clinbiomech.2019.10.019 10.1016/j.injury.2017.10.033 10.1016/j.clinbiomech.2019.12.004 10.3390/jfmk6030071 10.1111/os.12544 10.1016/j.knee.2018.03.015 10.1002/jbm.820241107 10.1016/j.piutam.2011.04.003 10.1038/s41598-018-34818-5 10.1016/j.actbio.2013.05.018 10.1016/j.injury.2015.11.010 10.1007/s00264-017-3563-6 10.1016/j.injury.2023.02.003 10.1097/md.0000000000027316 10.1186/s13018-018-1007-7 10.1177/1457496914520854 10.1177/1558944718795510 10.1097/bot.0b013e31818f8dc1 10.1155/2020/4186712 10.1016/j.knee.2008.07.004 10.1055/s-0040-1721026 10.1016/j.injury.2017.02.012 10.1016/j.knee.2011.02.004 10.3389/fphys.2021.750668 10.1097/bot.0b013e31802c5b51 10.12659/msm.927370 10.1097/bot.0000000000000170 10.1177/1081286515616049 10.1007/s11999-014-3975-1 10.3390/nano11102472 10.1007/s00402-022-04554-7 10.1186/s12891-021-04684-w 10.1016/s0736-0266(03)00240-7 10.1016/j.injury.2022.04.006 10.1097/00003086-199405000-00031 10.3389/fbioe.2022.818610 10.1097/bot.0000000000001129 10.1007/s11837-015-1341-8 10.1016/j.injury.2013.06.013 10.1186/s12891-021-04373-8 |
ContentType | Journal Article |
Copyright | Copyright © 2023 Hu, Ren, Peng, Gu, Wu, Wu, Zhang, Xu and Li. Copyright © 2023 Hu, Ren, Peng, Gu, Wu, Wu, Zhang, Xu and Li. 2023 Hu, Ren, Peng, Gu, Wu, Wu, Zhang, Xu and Li |
Copyright_xml | – notice: Copyright © 2023 Hu, Ren, Peng, Gu, Wu, Wu, Zhang, Xu and Li. – notice: Copyright © 2023 Hu, Ren, Peng, Gu, Wu, Wu, Zhang, Xu and Li. 2023 Hu, Ren, Peng, Gu, Wu, Wu, Zhang, Xu and Li |
DBID | AAYXX CITATION NPM 7X8 5PM DOA |
DOI | 10.3389/fbioe.2023.1286993 |
DatabaseName | CrossRef PubMed MEDLINE - Academic PubMed Central (Full Participant titles) DOAJ Directory of Open Access Journals |
DatabaseTitle | CrossRef PubMed MEDLINE - Academic |
DatabaseTitleList | CrossRef MEDLINE - Academic PubMed |
Database_xml | – sequence: 1 dbid: DOA name: DOAJ Directory of Open Access Journals url: https://www.doaj.org/ sourceTypes: Open Website – sequence: 2 dbid: NPM name: PubMed url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed sourceTypes: Index Database |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Engineering |
DocumentTitleAlternate | Hu et al |
EISSN | 2296-4185 |
ExternalDocumentID | oai_doaj_org_article_1fca385b5146497aaf606208dd2e1546 PMC10733506 38130819 10_3389_fbioe_2023_1286993 |
Genre | Journal Article |
GroupedDBID | 53G 5VS 9T4 AAFWJ AAYXX ACGFS ACXDI ADBBV ADRAZ AFPKN ALMA_UNASSIGNED_HOLDINGS AOIJS BAWUL BCNDV CITATION DIK GROUPED_DOAJ GX1 HYE KQ8 M48 M~E OK1 PGMZT RPM IAO IEA IHR IPNFZ ISR NPM RIG 7X8 5PM |
ID | FETCH-LOGICAL-c469t-5ac439fc5f1587d1b27a10bb97d4b18a551dba026318f075ee4fd2dc1a4930483 |
IEDL.DBID | DOA |
ISSN | 2296-4185 |
IngestDate | Wed Aug 27 01:30:16 EDT 2025 Thu Aug 21 18:37:38 EDT 2025 Fri Jul 11 16:23:04 EDT 2025 Thu Jan 02 22:34:38 EST 2025 Thu Apr 24 23:00:58 EDT 2025 Tue Jul 01 03:36:31 EDT 2025 |
IsDoiOpenAccess | true |
IsOpenAccess | true |
IsPeerReviewed | true |
IsScholarly | true |
Keywords | biomechanical research retention strength finite element analysis posterolateral tibial plateau fracture lateral approach |
Language | English |
License | Copyright © 2023 Hu, Ren, Peng, Gu, Wu, Wu, Zhang, Xu and Li. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
LinkModel | DirectLink |
MergedId | FETCHMERGED-LOGICAL-c469t-5ac439fc5f1587d1b27a10bb97d4b18a551dba026318f075ee4fd2dc1a4930483 |
Notes | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 Reviewed by: Francesco Travascio, University of Miami, United States Lei Zhang, Southwest Medical University, China These authors have contributed equally to this work and share first authorship Edited by: João Manuel R. S. Tavares, University of Porto, Portugal |
OpenAccessLink | https://doaj.org/article/1fca385b5146497aaf606208dd2e1546 |
PMID | 38130819 |
PQID | 2905515796 |
PQPubID | 23479 |
ParticipantIDs | doaj_primary_oai_doaj_org_article_1fca385b5146497aaf606208dd2e1546 pubmedcentral_primary_oai_pubmedcentral_nih_gov_10733506 proquest_miscellaneous_2905515796 pubmed_primary_38130819 crossref_citationtrail_10_3389_fbioe_2023_1286993 crossref_primary_10_3389_fbioe_2023_1286993 |
ProviderPackageCode | CITATION AAYXX |
PublicationCentury | 2000 |
PublicationDate | 2023-12-07 |
PublicationDateYYYYMMDD | 2023-12-07 |
PublicationDate_xml | – month: 12 year: 2023 text: 2023-12-07 day: 07 |
PublicationDecade | 2020 |
PublicationPlace | Switzerland |
PublicationPlace_xml | – name: Switzerland |
PublicationTitle | Frontiers in bioengineering and biotechnology |
PublicationTitleAlternate | Front Bioeng Biotechnol |
PublicationYear | 2023 |
Publisher | Frontiers Media S.A |
Publisher_xml | – name: Frontiers Media S.A |
References | Huang (B18) 2019; 70 Durigan (B9) 2023 Ren (B30) 2018; 8 Bronsnick (B5) 2015; 473 Sun (B37) 2017; 48 Ogaya (B24) 2014; 40 Mao (B22) 2021; 100 Shen (B33) 2019; 11 Mejia (B23) 2020; 15 Cai (B6) 2021; 22 Hu (B16) 2020; 2020 Hu (B17) 2016; 47 Velic (B42) 2021; 11 Addevico (B2) 2021; 6 Cho (B8) 2017; 41 Hebert-Davies (B13) 2013; 44 Lalwani (B21) 2013; 9 Higgins (B14) 2009; 23 Travascio (B41) 2015; 22 Tidwell (B40) 2016; 47 Amirouche (B3) 2011; 2 Zhang (B45) 2012; 19 Patel (B26) 2015; 67 Zhang (B44) 2020; 51 Parkkinen (B25) 2014; 103 Addevico (B1) 2020; 72 Jiang (B19) 2018; 13 Rancourt (B29) 1990; 24 Chen (B7) 2020; 26 Giordano (B12) 2022; 35 Sun (B36) 2018; 25 Schatzker (B32) 2022; 53 Rademakers (B28) 2007; 21 Taylor (B39) 2004; 22 Honkonen (B15) 1994; 302 Qiu (B27) 2011; 33 Ren (B31) 2022; 10 Volz (B43) 2021; 12 Kim (B20) 2018; 32 Feng (B10) 2021; 22 Tao (B38) 2008; 15 Anwar (B4) 2017; 48 Gao (B11) 2023; 143 Shuaishuai (B34) 2023; 11 Sohn (B35) 2015; 29 |
References_xml | – volume: 40 start-page: 341 year: 2014 ident: B24 article-title: Knee adduction moment and medial knee contact force during gait in older people publication-title: Gait Posture doi: 10.1016/j.gaitpost.2014.04.205 – volume: 11 start-page: 1150541 year: 2023 ident: B34 article-title: Clinical application of the modified posterolateral approach for treating posterior tibial plateau fractures publication-title: Front. Bioeng. Biotechnol. doi: 10.3389/fbioe.2023.1150541 – volume: 51 start-page: 2465 year: 2020 ident: B44 article-title: Biomechanical analysis of "Barrel hoop plate" technique for the posterolateral fragments of tibial plateau fractures with different displacement tendency publication-title: Injury doi: 10.1016/j.injury.2020.07.059 – volume: 33 start-page: 1228 year: 2011 ident: B27 article-title: Finite element modeling of a 3D coupled foot-boot model publication-title: Med. Eng. Phys. doi: 10.1016/j.medengphy.2011.05.012 – volume: 47 start-page: 1624 year: 2016 ident: B40 article-title: The biomechanical cost of variable angle locking screws publication-title: Injury doi: 10.1016/j.injury.2016.06.001 – volume: 70 start-page: 203 year: 2019 ident: B18 article-title: Biomechanical comparison of a 3D-printed sacrum prosthesis versus rod-screw systems for reconstruction after total sacrectomy: a finite element analysis publication-title: Clin. Biomech. (Bristol, Avon) doi: 10.1016/j.clinbiomech.2019.10.019 – volume: 48 start-page: 2814 year: 2017 ident: B37 article-title: Reinforcement strategy for lateral rafting plate fixation in posterolateral column fractures of the tibial plateau: the magic screw technique publication-title: Injury doi: 10.1016/j.injury.2017.10.033 – volume: 72 start-page: 130 year: 2020 ident: B1 article-title: Screw insertion torque as parameter to judge the fixation. Assessment of torque and pull-out strength in different bone densities and screw-pitches publication-title: Clin. Biomech. (Bristol, Avon) doi: 10.1016/j.clinbiomech.2019.12.004 – volume: 6 start-page: 71 year: 2021 ident: B2 article-title: Salvaging pull-out strength in a previously stripped screw site: a comparison of three rescue techniques publication-title: J. Funct. Morphol. Kinesiol doi: 10.3390/jfmk6030071 – volume: 11 start-page: 1029 year: 2019 ident: B33 article-title: Surgical treatment of lateral tibial plateau fractures involving the posterolateral column publication-title: Orthop. Surg. doi: 10.1111/os.12544 – volume: 25 start-page: 417 year: 2018 ident: B36 article-title: A biomechanical evaluation of different fixation strategies for posterolateral fragments in tibial plateau fractures and introduction of the 'magic screw publication-title: Knee doi: 10.1016/j.knee.2018.03.015 – volume: 24 start-page: 1503 year: 1990 ident: B29 article-title: Friction properties of the interface between porous-surfaced metals and tibial cancellous bone publication-title: J. Biomed. Mater. Res. doi: 10.1002/jbm.820241107 – volume: 2 start-page: 18 year: 2011 ident: B3 article-title: Challenges in modeling total knee arthroplasty and total hip replacement publication-title: Procedia IUTAM doi: 10.1016/j.piutam.2011.04.003 – volume: 8 start-page: 16418 year: 2018 ident: B30 article-title: A novel design of a plate for posterolateral tibial plateau fractures through traditional anterolateral approach publication-title: Sci. Rep. doi: 10.1038/s41598-018-34818-5 – volume: 9 start-page: 8365 year: 2013 ident: B21 article-title: Tungsten disulfide nanotubes reinforced biodegradable polymers for bone tissue engineering publication-title: Acta biomater. doi: 10.1016/j.actbio.2013.05.018 – volume: 47 start-page: 502 year: 2016 ident: B17 article-title: The anterolateral supra-fibular-head approach for plating posterolateral tibial plateau fractures: a novel surgical technique publication-title: Injury doi: 10.1016/j.injury.2015.11.010 – volume: 41 start-page: 1887 year: 2017 ident: B8 article-title: Approaches and fixation of the posterolateral fracture fragment in tibial plateau fractures: a review with an emphasis on rim plating via modified anterolateral approach publication-title: Int. Orthop. doi: 10.1007/s00264-017-3563-6 – start-page: 00100 year: 2023 ident: B9 article-title: TEMPORARY REMOVAL: depression fractures of the posterolateral tibial plateau: treatment by lateral femoral epicondyle osteotomy approach publication-title: Injury doi: 10.1016/j.injury.2023.02.003 – volume: 100 start-page: e27316 year: 2021 ident: B22 article-title: Treatment of tibial plateau fractures involving the posterolateral column using the extended anterolateral approach publication-title: Medicine doi: 10.1097/md.0000000000027316 – volume: 13 start-page: 303 year: 2018 ident: B19 article-title: Comparison of extended anterolateral approach in treatment of simple/complex tibial plateau fracture with posterolateral tibial plateau fracture publication-title: J. Orthop. Surg. Res. doi: 10.1186/s13018-018-1007-7 – volume: 103 start-page: 256 year: 2014 ident: B25 article-title: Factors predicting the development of early osteoarthritis following lateral tibial plateau fractures: mid-term clinical and radiographic outcomes of 73 operatively treated patients publication-title: Scand. J. Surg. doi: 10.1177/1457496914520854 – volume: 15 start-page: 393 year: 2020 ident: B23 article-title: Pullout strength after multiple reinsertions in radial bone fixation publication-title: Hand (N Y) doi: 10.1177/1558944718795510 – volume: 23 start-page: 45 year: 2009 ident: B14 article-title: Incidence and morphology of the posteromedial fragment in bicondylar tibial plateau fractures publication-title: J. Orthop. Trauma doi: 10.1097/bot.0b013e31818f8dc1 – volume: 2020 start-page: 1 year: 2020 ident: B16 article-title: Treatment of isolated posterolateral tibial plateau fracture with a horizontal belt plate through the anterolateral supra-fibular-head approach publication-title: BioMed Res. Int. doi: 10.1155/2020/4186712 – volume: 15 start-page: 473 year: 2008 ident: B38 article-title: The posterolateral shearing tibial plateau fracture: publication-title: Knee doi: 10.1016/j.knee.2008.07.004 – volume: 35 start-page: 959 year: 2022 ident: B12 article-title: Posterolateral fractures of the tibial plateau revisited: a simplified treatment algorithm publication-title: J. knee Surg. doi: 10.1055/s-0040-1721026 – volume: 48 start-page: 825 year: 2017 ident: B4 article-title: Finite element analysis of the three different posterior malleolus fixation strategies in relation to different fracture sizes publication-title: Injury doi: 10.1016/j.injury.2017.02.012 – volume: 19 start-page: 94 year: 2012 ident: B45 article-title: Biomechanical analysis of four different fixations for the posterolateral shearing tibial plateau fracture publication-title: Knee doi: 10.1016/j.knee.2011.02.004 – volume: 12 start-page: 750668 year: 2021 ident: B43 article-title: Computational modeling intervertebral disc pathophysiology: a review publication-title: Front. physiology doi: 10.3389/fphys.2021.750668 – volume: 21 start-page: 5 year: 2007 ident: B28 article-title: Operative treatment of 109 tibial plateau fractures: five-to 27-year follow-up results publication-title: J. Orthop. Trauma doi: 10.1097/bot.0b013e31802c5b51 – volume: 26 start-page: e927370 year: 2020 ident: B7 article-title: Fibular neck osteotomy approach in treatment of posterolateral tibial plateau fractures: a retrospective case series publication-title: Med. Sci. Monit. Int. Med. J. Exp. Clin. Res. doi: 10.12659/msm.927370 – volume: 29 start-page: 91 year: 2015 ident: B35 article-title: Incidence and fracture morphology of posterolateral fragments in lateral and bicondylar tibial plateau fractures publication-title: J. Orthop. trauma doi: 10.1097/bot.0000000000000170 – volume: 22 start-page: 952 year: 2015 ident: B41 article-title: Analysis of the consolidation problem of compressible porous media by a macroscopic variational continuum approach publication-title: Math. Mech. Solids doi: 10.1177/1081286515616049 – volume: 473 start-page: 1150 year: 2015 ident: B5 article-title: Can high-friction intraannular material increase screw pullout strength in osteoporotic bone? publication-title: Clin. Orthop. Relat. Res. doi: 10.1007/s11999-014-3975-1 – volume: 11 start-page: 2472 year: 2021 ident: B42 article-title: Effects of nanopillar size and spacing on mechanical perturbation and bactericidal killing efficiency publication-title: Nanomater. (Basel, Switz. doi: 10.3390/nano11102472 – volume: 143 start-page: 3163 year: 2023 ident: B11 article-title: Lateral locking plate plus antero-posterior lag screws techniques for the management of posterolateral tibial plateau fracture: preliminary clinical results and biomechanical study publication-title: Archives Orthop. trauma Surg. doi: 10.1007/s00402-022-04554-7 – volume: 22 start-page: 804 year: 2021 ident: B6 article-title: The treatment of posterolateral tibial plateau fracture with a newly designed anatomical plate via the trans-supra-fibular head approach: preliminary outcomes publication-title: BMC Musculoskelet. Disord. doi: 10.1186/s12891-021-04684-w – volume: 22 start-page: 625 year: 2004 ident: B39 article-title: Tibio-femoral loading during human gait and stair climbing publication-title: J. Orthop. Res. official Publ. Orthop. Res. Soc. doi: 10.1016/s0736-0266(03)00240-7 – volume: 53 start-page: 2207 year: 2022 ident: B32 article-title: Revisiting the management of tibial plateau fractures publication-title: Injury doi: 10.1016/j.injury.2022.04.006 – volume: 302 start-page: 199 year: 1994 ident: B15 article-title: Indications for surgical treatment of tibial condyle fractures publication-title: Clin. Orthop. Relat. Res. doi: 10.1097/00003086-199405000-00031 – volume: 10 start-page: 818610 year: 2022 ident: B31 article-title: The study of Biomechanics and clinical anatomy on a novel plate designed for posterolateral tibial plateau fractures via anterolateral approach publication-title: Front. Bioeng. Biotechnol. doi: 10.3389/fbioe.2022.818610 – volume: 32 start-page: e157 year: 2018 ident: B20 article-title: Rim Plate augmentation of the posterolateral bare area of the tibial plateau using a 3.5-mm precontoured locking compression plate: a cadaveric study publication-title: J. Orthop. trauma doi: 10.1097/bot.0000000000001129 – volume: 67 start-page: 2518 year: 2015 ident: B26 article-title: Nanotopography and surface stress analysis of Ti6Al4V bioimplant: an alternative design for stability publication-title: Jom doi: 10.1007/s11837-015-1341-8 – volume: 44 start-page: 1358 year: 2013 ident: B13 article-title: A biomechanical study comparing polyaxial locking screw mechanisms publication-title: Injury doi: 10.1016/j.injury.2013.06.013 – volume: 22 start-page: 488 year: 2021 ident: B10 article-title: A posterolateral sheared fracture of the tibial plateau: a case presentation publication-title: BMC Musculoskelet. Disord. doi: 10.1186/s12891-021-04373-8 |
SSID | ssj0001257582 |
Score | 2.2524815 |
Snippet | Objective:
The treatment for posterolateral tibial plateau fractures (PTPF) have been subjects of controversy. We conducted a study to improve the fixation of... The treatment for posterolateral tibial plateau fractures (PTPF) have been subjects of controversy. We conducted a study to improve the fixation of PTPF... Objective: The treatment for posterolateral tibial plateau fractures (PTPF) have been subjects of controversy. We conducted a study to improve the fixation of... |
SourceID | doaj pubmedcentral proquest pubmed crossref |
SourceType | Open Website Open Access Repository Aggregation Database Index Database Enrichment Source |
StartPage | 1286993 |
SubjectTerms | Bioengineering and Biotechnology biomechanical research finite element analysis lateral approach posterolateral tibial plateau fracture retention strength |
SummonAdditionalLinks | – databaseName: Scholars Portal Journals: Open Access dbid: M48 link: http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwrV1La9wwEB6S9JIcSh95OH2gQG_FieW3DqU0oSGUJvSQhdyEZEmJYbG33l3Y3PvDO2N5l2xJcurNyJItNBrN99nzAPiERkkZJdKQXAiRoAgbKuPKUCPUsEIrtHH0R_fyKr8YpT9uspsNWJY7GhZw-ii1o3pSo258vPh9_xUV_gsxTrS3J07XLWW8jJNjPG1ztLib8AItU0GKejnAff_NBcFJGfvYmSeGrtmnPo3_Y9jzXxfKBzbp_BW8HMAk--al_xo2bPMGdh6kGHwLf04pvp7Ce-tqylRjmKsJZjLr_caxyWclYd4bHQexCQV-dHXbsetwMiYwyuhzLft59oshxsUnLHp5stYNfVvqhRNkPgKF9aOYowisOfL5XRidf78-uwiHygthhXR5FmaqQqDiqszxrCwM13GheKS1KEyqeakQZhmtkL7hieAQdFibOhObiqtUJJSkfg-2mraxB8BiURWutC5BMJByFymBnEiZvNB4iW8IgC_XW1ZDWnKqjjGWSE9IRrKXkSQZyUFGAXxejZn4pBzP9j4lMa56UkLtvqHtbuWgn5K7SiVlphE_5qkolHLI7OKoNCa2iDLzAI6Wm0CiAtJfFdXYdj6VsYhwOSikN4B9vylWr0I4lBDmCqBc2y5rc1m_09R3fZJvTtU0syg__B-zfwfbtCK9G07xHrZm3dx-QDA10x97DfkLgTggfQ priority: 102 providerName: Scholars Portal |
Title | Biomechanics and finite element analysis comparing posterior T-plates with LCP for fixation of posterolateral tibial plate fractures |
URI | https://www.ncbi.nlm.nih.gov/pubmed/38130819 https://www.proquest.com/docview/2905515796 https://pubmed.ncbi.nlm.nih.gov/PMC10733506 https://doaj.org/article/1fca385b5146497aaf606208dd2e1546 |
Volume | 11 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwrV1Na9wwEBUlp_RQmn66aYMKvRU3lj-lYxMSQmlKDwnkJiRLooZgL5td6A_oD-8byVl2Q2kvvRhjS5bQjDxvpJknxj7AKBlnVJ1TCCEcFOVz44LMLaCGV9bAxtGO7uW39uK6_nLT3Gwd9UUxYYkeOA3csQi9qWRjYdjbWnXGBEDuspDOlR7mP5Jtw-ZtOVNpdQUwRJYpSwZemDoOdpiIFrOsPuGX3CpV7ViiSNj_J5T5MFhyy_qcP2VPZtjIP6fuHrBHfnzGHm-RCT5nv04ok54SeYf-jpvR8TAQoOQ-RYjjUeIf4SnuHJX4glI8lsO05Ff54pZgJ6eFWf719DsHmsUXfkbJ8SnMZScqhQ7ylGvCYy0eKNdqDc_9Bbs-P7s6vcjnMxbyHo7xKm9MD0gS-iaIRnZO2LIzorBWda62QhoAKmcNHDXM_QB44X0dXOl6YWpVER39S7Y3TqN_zXip-i5IHyqY_VqEwih4P8a1ncUtWsiYuB9v3c8E5HQOxq2GI0Iy0lFGmmSkZxll7OOmziLRb_y19AmJcVOSqLPjAyiUnhVK_0uhMvb-Xgk0phrtn5jRT-s7XaoCw0HJuxl7lZRi0xSAT0XoKmNyR112-rL7Zhx-RDpvQedmNkX75n_0_pDt04jEgJvuLdtbLdf-HWDTyh7FGYLrZS1_A-8LGHU |
linkProvider | Directory of Open Access Journals |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Biomechanics+and+finite+element+analysis+comparing+posterior+T-plates+with+LCP+for+fixation+of+posterolateral+tibial+plate+fractures&rft.jtitle=Frontiers+in+bioengineering+and+biotechnology&rft.au=Zhenghui+Hu&rft.au=Weizhi+Ren&rft.au=Jian+Peng&rft.au=Zenghui+Gu&rft.date=2023-12-07&rft.pub=Frontiers+Media+S.A&rft.eissn=2296-4185&rft.volume=11&rft_id=info:doi/10.3389%2Ffbioe.2023.1286993&rft.externalDBID=DOA&rft.externalDocID=oai_doaj_org_article_1fca385b5146497aaf606208dd2e1546 |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=2296-4185&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=2296-4185&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=2296-4185&client=summon |