Adverse Events Following Transcatheter Edge-to-Edge Repair (TEER) Using MitraClip: Lessons Learned From the Manufacturer and User Facility Device Experience (MAUDE) Registry

The MitraClip from Abbott is FDA approved intracardiac implantable device for transcatheter edge-to-edge repair (TEER). Despite a few previously published studies, there is limited safety data for its use in clinical practice, hence, we designed this study using data obtained from a safety nationwid...

Full description

Saved in:
Bibliographic Details
Published inCardiovascular revascularization medicine Vol. 39; pp. 101 - 105
Main Authors Dodoo, Sheriff N., Okoh, Alexis K., Oseni, Abdullahi, Odiete, Oghenerukevwe, Okafor, Henry E.
Format Journal Article
LanguageEnglish
Published United States Elsevier Inc 01.06.2022
Subjects
Online AccessGet full text

Cover

Loading…
Abstract The MitraClip from Abbott is FDA approved intracardiac implantable device for transcatheter edge-to-edge repair (TEER). Despite a few previously published studies, there is limited safety data for its use in clinical practice, hence, we designed this study using data obtained from a safety nationwide database to demonstrate the safety profile of MitraClip. The first two of the five authors independently queried all reported adverse events from the United State Food and Drug Administration [FDA] Manufacturer and User Facility Device Experience [MAUDE] registry from January 2014 to December 2020. The primary end point was trend in reported fatal events obtained from this database. The secondary end points included the causes of reported nonfatal reports from the MAUDE registry. The trend of reported fatal events was assessed using the Cochran Armitage trend test over the period of the study. During the study period, subjects included 3370 patients whose MitraClip-associated adverse events were reported and captured by MAUDE registry. Of these, 211 were fatal and 3159 nonfatal events. Fatal event reports resulted deaths and reported nonfatal events were from injuries and device system malfunction. This study demonstrated an initial upward trend from 2014 to 2015 then a subsequent statistically significant downward trend in reported fatal events from 2015 to 2020 (Cochran-Armitage test P = 0.039). The peak proportion of reported fatal events occurred in 2015, (n = 44; representing 1.25% of reported adverse events) and lowest proportion of reported fatal events took place in 2020 (n = 19; representing 0.56% of reported adverse events). The most reported nonfatal events were from malfunctioning of MitraClip system (n = 1170; representing 37% of reported nonfatal events), new unremarkable repolarization abnormalities on periprocedural EKG (n = 864; representing 27% of reported nonfatal events), leaflet rupture (n = 651; representing 21% of reported nonfatal events), and cardiogenic shock (n = 170; representing 5% of reported nonfatal events). This analysis of the MAUDE Registry indicated, especially within the confines of this study's limitations and poor data quality of information, an apparent downward trend of reported fatal events over the study period. Even though conclusive attributions cannot be made regarding this important finding, perhaps, this points to early evidence of a potential institutional or operator learning curve with this device. However, in view of the inferior quality of the data accrued from the MAUDE Registry, more high-precision studies are needed to better understand these changes, as the utility of MitraClip, becomes more established in clinical practice.
AbstractList The MitraClip from Abbott is FDA approved intracardiac implantable device for transcatheter edge-to-edge repair (TEER). Despite a few previously published studies, there is limited safety data for its use in clinical practice, hence, we designed this study using data obtained from a safety nationwide database to demonstrate the safety profile of MitraClip. The first two of the five authors independently queried all reported adverse events from the United State Food and Drug Administration [FDA] Manufacturer and User Facility Device Experience [MAUDE] registry from January 2014 to December 2020. The primary end point was trend in reported fatal events obtained from this database. The secondary end points included the causes of reported nonfatal reports from the MAUDE registry. The trend of reported fatal events was assessed using the Cochran Armitage trend test over the period of the study. During the study period, subjects included 3370 patients whose MitraClip-associated adverse events were reported and captured by MAUDE registry. Of these, 211 were fatal and 3159 nonfatal events. Fatal event reports resulted deaths and reported nonfatal events were from injuries and device system malfunction. This study demonstrated an initial upward trend from 2014 to 2015 then a subsequent statistically significant downward trend in reported fatal events from 2015 to 2020 (Cochran-Armitage test P = 0.039). The peak proportion of reported fatal events occurred in 2015, (n = 44; representing 1.25% of reported adverse events) and lowest proportion of reported fatal events took place in 2020 (n = 19; representing 0.56% of reported adverse events). The most reported nonfatal events were from malfunctioning of MitraClip system (n = 1170; representing 37% of reported nonfatal events), new unremarkable repolarization abnormalities on periprocedural EKG (n = 864; representing 27% of reported nonfatal events), leaflet rupture (n = 651; representing 21% of reported nonfatal events), and cardiogenic shock (n = 170; representing 5% of reported nonfatal events). This analysis of the MAUDE Registry indicated, especially within the confines of this study's limitations and poor data quality of information, an apparent downward trend of reported fatal events over the study period. Even though conclusive attributions cannot be made regarding this important finding, perhaps, this points to early evidence of a potential institutional or operator learning curve with this device. However, in view of the inferior quality of the data accrued from the MAUDE Registry, more high-precision studies are needed to better understand these changes, as the utility of MitraClip, becomes more established in clinical practice.
OBJECTIVEThe MitraClip from Abbott is FDA approved intracardiac implantable device for transcatheter edge-to-edge repair (TEER). Despite a few previously published studies, there is limited safety data for its use in clinical practice, hence, we designed this study using data obtained from a safety nationwide database to demonstrate the safety profile of MitraClip.METHODSThe first two of the five authors independently queried all reported adverse events from the United State Food and Drug Administration [FDA] Manufacturer and User Facility Device Experience [MAUDE] registry from January 2014 to December 2020. The primary end point was trend in reported fatal events obtained from this database. The secondary end points included the causes of reported nonfatal reports from the MAUDE registry. The trend of reported fatal events was assessed using the Cochran Armitage trend test over the period of the study.RESULTSDuring the study period, subjects included 3370 patients whose MitraClip-associated adverse events were reported and captured by MAUDE registry. Of these, 211 were fatal and 3159 nonfatal events. Fatal event reports resulted deaths and reported nonfatal events were from injuries and device system malfunction. This study demonstrated an initial upward trend from 2014 to 2015 then a subsequent statistically significant downward trend in reported fatal events from 2015 to 2020 (Cochran-Armitage test P = 0.039). The peak proportion of reported fatal events occurred in 2015, (n = 44; representing 1.25% of reported adverse events) and lowest proportion of reported fatal events took place in 2020 (n = 19; representing 0.56% of reported adverse events). The most reported nonfatal events were from malfunctioning of MitraClip system (n = 1170; representing 37% of reported nonfatal events), new unremarkable repolarization abnormalities on periprocedural EKG (n = 864; representing 27% of reported nonfatal events), leaflet rupture (n = 651; representing 21% of reported nonfatal events), and cardiogenic shock (n = 170; representing 5% of reported nonfatal events).CONCLUSIONSThis analysis of the MAUDE Registry indicated, especially within the confines of this study's limitations and poor data quality of information, an apparent downward trend of reported fatal events over the study period. Even though conclusive attributions cannot be made regarding this important finding, perhaps, this points to early evidence of a potential institutional or operator learning curve with this device. However, in view of the inferior quality of the data accrued from the MAUDE Registry, more high-precision studies are needed to better understand these changes, as the utility of MitraClip, becomes more established in clinical practice.
Author Dodoo, Sheriff N.
Oseni, Abdullahi
Okoh, Alexis K.
Okafor, Henry E.
Odiete, Oghenerukevwe
AuthorAffiliation c Division of Cardiology, Department of Medicine, Oklahoma University College of Medicine, United States of America
b Division of Cardiology, Department of Medicine, Emory University School of Medicine, United States of America
e Division of Cardiology, Department of Medicine, Vanderbilt University School of Medicine, United States of America
a Department of Internal Medicine, Piedmont Newnan Hospital, United States of America
d Peach-state Advanced Cardiac and Endovascular Center, Newnan, Georgia
AuthorAffiliation_xml – name: d Peach-state Advanced Cardiac and Endovascular Center, Newnan, Georgia
– name: a Department of Internal Medicine, Piedmont Newnan Hospital, United States of America
– name: e Division of Cardiology, Department of Medicine, Vanderbilt University School of Medicine, United States of America
– name: b Division of Cardiology, Department of Medicine, Emory University School of Medicine, United States of America
– name: c Division of Cardiology, Department of Medicine, Oklahoma University College of Medicine, United States of America
Author_xml – sequence: 1
  givenname: Sheriff N.
  surname: Dodoo
  fullname: Dodoo, Sheriff N.
  email: sheriff.dodoo@gmail.com
  organization: Department of Internal Medicine, Piedmont Newnan Hospital, United States of America
– sequence: 2
  givenname: Alexis K.
  surname: Okoh
  fullname: Okoh, Alexis K.
  organization: Division of Cardiology, Department of Medicine, Emory University School of Medicine, United States of America
– sequence: 3
  givenname: Abdullahi
  surname: Oseni
  fullname: Oseni, Abdullahi
  organization: Division of Cardiology, Department of Medicine, Oklahoma University College of Medicine, United States of America
– sequence: 4
  givenname: Oghenerukevwe
  surname: Odiete
  fullname: Odiete, Oghenerukevwe
  organization: Peach-state Advanced Cardiac and Endovascular Center, Newnan, Georgia
– sequence: 5
  givenname: Henry E.
  surname: Okafor
  fullname: Okafor, Henry E.
  organization: Division of Cardiology, Department of Medicine, Vanderbilt University School of Medicine, United States of America
BackLink https://www.ncbi.nlm.nih.gov/pubmed/34610901$$D View this record in MEDLINE/PubMed
BookMark eNp9UU2P0zAQjdAi9gP-AUI-dg8ptpPGCQdWVTcFpFZIq_ZsTZxJ11VqF9sN9EfxH3HpsoILp3nSvI_RvOvkwliDSfKW0TGjrHi_HStwDocxp5yNaTWmVLxIrlgpypRWWXkR8WSSpWVWVpfJtfdbSjPBC_EquczygtGKsqvk57Qd0Hkk9YAmeDK3fW-_a7MhKwfGKwiPGNCRut1gGmx6muQB96AdGa3q-uGWrP2JvtTBwazX-w9kgd5b4-MEZ7Alc2d3JPqQJZhDByocXHQE00ZpBHNQutfhSO5x0Cpe8mOPTqOJcLScru_r2xi40T644-vkZQe9xzdP8yZZz-vV7HO6-Prpy2y6SFVe5CFVXKFiZZkr4Ew00DFsoWuarlMNL0XGG5VlmNNWnEiUqwrERFEQ2CmRA8tukruz7_7Q7LBV8TUOerl3egfuKC1o-e_G6Ee5sYNktKwmuSiiw-jJwdlvB_RB7rRX2Pdg0B685BNRFVxUgkdqfqYqZ7132D3nMCpPVcutPFctT1VLWslYdZS9-_vGZ9GfbiPh45mA8VODRie9-v3WVjtUQbZW_z_hF-duwbA
CitedBy_id crossref_primary_10_1016_j_case_2022_07_004
crossref_primary_10_1097_PTS_0000000000001220
crossref_primary_10_1016_j_carrev_2023_01_005
Cites_doi 10.1016/j.ihj.2015.08.025
10.1016/j.jacc.2013.02.094
10.1056/NEJMoa1806640
10.1016/j.ahj.2017.10.013
10.1016/0002-9149(81)90142-9
10.1016/S0195-668X(03)00201-X
10.1016/j.jacc.2013.12.062
10.1016/S0140-6736(09)60692-9
10.1016/S0140-6736(06)69208-8
ContentType Journal Article
Copyright 2021 Elsevier Inc.
Copyright © 2021 Elsevier Inc. All rights reserved.
Copyright_xml – notice: 2021 Elsevier Inc.
– notice: Copyright © 2021 Elsevier Inc. All rights reserved.
DBID CGR
CUY
CVF
ECM
EIF
NPM
AAYXX
CITATION
7X8
5PM
DOI 10.1016/j.carrev.2021.09.007
DatabaseName Medline
MEDLINE
MEDLINE (Ovid)
MEDLINE
MEDLINE
PubMed
CrossRef
MEDLINE - Academic
PubMed Central (Full Participant titles)
DatabaseTitle MEDLINE
Medline Complete
MEDLINE with Full Text
PubMed
MEDLINE (Ovid)
CrossRef
MEDLINE - Academic
DatabaseTitleList MEDLINE
MEDLINE - Academic

Database_xml – sequence: 1
  dbid: NPM
  name: PubMed
  url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed
  sourceTypes: Index Database
– sequence: 2
  dbid: EIF
  name: MEDLINE
  url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search
  sourceTypes: Index Database
DeliveryMethod fulltext_linktorsrc
Discipline Medicine
EISSN 1878-0938
EndPage 105
ExternalDocumentID 10_1016_j_carrev_2021_09_007
34610901
S1553838921006692
Genre Journal Article
GeographicLocations United States
GeographicLocations_xml – name: United States
GrantInformation_xml – fundername: NHLBI NIH HHS
  grantid: T32 HL130025
GroupedDBID ---
--K
--M
.1-
.FO
.~1
0R~
1B1
1P~
1~.
1~5
29B
4.4
457
4G.
53G
5GY
5VS
6PF
7-5
71M
8P~
AACTN
AAEDT
AAEDW
AAIAV
AAIKJ
AAKOC
AALRI
AAOAW
AAQFI
AAWTL
AAXUO
ABBQC
ABGSF
ABJNI
ABLVK
ABMAC
ABMZM
ABUDA
ABXDB
ABYKQ
ACDAQ
ACGFS
ACIUM
ACRLP
ADBBV
ADEZE
ADMUD
ADUVX
AEBSH
AEHWI
AEKER
AEVXI
AFCTW
AFKWA
AFRHN
AFTJW
AFXIZ
AGHFR
AGUBO
AGYEJ
AIEXJ
AIKHN
AITUG
AJBFU
AJOXV
AJRQY
AJUYK
ALMA_UNASSIGNED_HOLDINGS
AMFUW
AMRAJ
ANZVX
AXJTR
BKOJK
BLXMC
BNPGV
CS3
DOVZS
EBS
EFJIC
EFLBG
EJD
EO8
EO9
EP2
EP3
F5P
FDB
FEDTE
FIRID
FNPLU
FYGXN
G-Q
GBLVA
HVGLF
HZ~
IHE
J1W
KOM
LCYCR
M41
MO0
N9A
O-L
O9-
OAUVE
OA~
OL0
OZT
P-8
P-9
P2P
PC.
Q38
RIG
ROL
RPZ
SDF
SDG
SEL
SES
SEW
SPCBC
SSH
SSU
SSZ
T5K
Z5R
~G-
AAXKI
AFJKZ
AKRWK
CGR
CUY
CVF
ECM
EIF
NPM
AAYXX
ACRPL
ADNMO
CITATION
7X8
5PM
ID FETCH-LOGICAL-c464t-c2cec1884ca217baf1edafbbffcb28732bc33e40d7188402c9a75c0a7efc74a13
IEDL.DBID .~1
ISSN 1553-8389
IngestDate Tue Sep 17 21:28:46 EDT 2024
Wed Dec 04 03:01:43 EST 2024
Fri Dec 06 02:42:07 EST 2024
Sat Nov 02 11:57:58 EDT 2024
Fri Feb 23 02:40:29 EST 2024
IsDoiOpenAccess false
IsOpenAccess true
IsPeerReviewed true
IsScholarly true
Keywords MitraClip
Adverse events
Fatal events
Language English
License Copyright © 2021 Elsevier Inc. All rights reserved.
LinkModel DirectLink
MergedId FETCHMERGED-LOGICAL-c464t-c2cec1884ca217baf1edafbbffcb28732bc33e40d7188402c9a75c0a7efc74a13
Notes ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
OpenAccessLink https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10895476
PMID 34610901
PQID 2579627972
PQPubID 23479
PageCount 5
ParticipantIDs pubmedcentral_primary_oai_pubmedcentral_nih_gov_10895476
proquest_miscellaneous_2579627972
crossref_primary_10_1016_j_carrev_2021_09_007
pubmed_primary_34610901
elsevier_sciencedirect_doi_10_1016_j_carrev_2021_09_007
PublicationCentury 2000
PublicationDate 2022-06-01
PublicationDateYYYYMMDD 2022-06-01
PublicationDate_xml – month: 06
  year: 2022
  text: 2022-06-01
  day: 01
PublicationDecade 2020
PublicationPlace United States
PublicationPlace_xml – name: United States
PublicationTitle Cardiovascular revascularization medicine
PublicationTitleAlternate Cardiovasc Revasc Med
PublicationYear 2022
Publisher Elsevier Inc
Publisher_xml – name: Elsevier Inc
References Stone, Lindenfeld, Abraham, Kar, Lim, Mishell (bb0040) 2018; 379
Nkomo, Gardin, Skelton, Gottdiener, Scott, Enriquez-Sarano (bb0005) 2006; 368
Mahabir, DeFilippis, Aggarwal, Bath, Qamar, Patel (bb0065) 2020; 32
Lung, Baron, Butchart, Delahaye, Gohlke-Bärwolf, Levang (bb0015) 2003; 24
Vahanian, Alfieri, Andreotti, Antunes, Baron-Esquivias, Baumgartner (bb0025) 2013; 14
Benjamin, David, Gregory, Englander (bb0060) 2018; 198
Kelley, Lazkani, Farah, Pershad (bb0055) 2016; 68
MAUDE (bb0050)
Maisano, Franzen, Baldus, Schäfer, Hausleiter, Butter (bb0030) 2013; 62
Otto, Nishimura, Bonow, Carabello, Erwin, Gentile (bb0045) 2021; 143
Glower, Kar, Trento, Lim, Bajwa, Quesada (bb0035) 2014; 64
Enriquez-Sarano, Akins, Vahanian (bb0010) 2009; 373
Phillips, Levine, Carter, Boucher, Osbakken, Okada (bb0020) 1981; 48
Glower (10.1016/j.carrev.2021.09.007_bb0035) 2014; 64
Enriquez-Sarano (10.1016/j.carrev.2021.09.007_bb0010) 2009; 373
Lung (10.1016/j.carrev.2021.09.007_bb0015) 2003; 24
Nkomo (10.1016/j.carrev.2021.09.007_bb0005) 2006; 368
Mahabir (10.1016/j.carrev.2021.09.007_bb0065) 2020; 32
Stone (10.1016/j.carrev.2021.09.007_bb0040) 2018; 379
Otto (10.1016/j.carrev.2021.09.007_bb0045) 2021; 143
MAUDE (10.1016/j.carrev.2021.09.007_bb0050)
Kelley (10.1016/j.carrev.2021.09.007_bb0055) 2016; 68
Benjamin (10.1016/j.carrev.2021.09.007_bb0060) 2018; 198
Maisano (10.1016/j.carrev.2021.09.007_bb0030) 2013; 62
Phillips (10.1016/j.carrev.2021.09.007_bb0020) 1981; 48
Vahanian (10.1016/j.carrev.2021.09.007_bb0025) 2013; 14
References_xml – volume: 62
  start-page: 1052
  year: 2013
  end-page: 1061
  ident: bb0030
  article-title: Percutaneous mitral valve interventions in the real world: early and 1- year results from the ACCESS-EU, a prospective, multicenter, non-randomized post-approval study of the MitraClip therapy in Europe
  publication-title: J Am Coll Cardiol
  contributor:
    fullname: Butter
– volume: 373
  start-page: 1382
  year: 2009
  end-page: 1394
  ident: bb0010
  article-title: Mitral regurgitation
  publication-title: Lancet
  contributor:
    fullname: Vahanian
– ident: bb0050
  article-title: Manufacturer and user facility device experience
  contributor:
    fullname: MAUDE
– volume: 24
  start-page: 1231
  year: 2003
  end-page: 1243
  ident: bb0015
  article-title: A prospective survey of patients with valvular heart disease in Europe: the euro heart survey on valvular heart disease
  publication-title: Eur Heart J
  contributor:
    fullname: Levang
– volume: 368
  start-page: 1005
  year: 2006
  end-page: 1011
  ident: bb0005
  article-title: Burden of valvular heart diseases: a population-based study
  publication-title: Lancet.
  contributor:
    fullname: Enriquez-Sarano
– volume: 14
  start-page: 167
  year: 2013
  end-page: 214
  ident: bb0025
  article-title: Joint task force on the Management of Valvular Heart Disease of the European Society of Cardiology (ESC) and the European Association for Cardio-Thoracic Surgery (EACTS)
  publication-title: G Ital Cardiol (Rome)
  contributor:
    fullname: Baumgartner
– volume: 68
  start-page: 399
  year: 2016
  end-page: 404
  ident: bb0055
  article-title: Percutaneous mitral valve repair: a new treatment for mitral regurgitation
  publication-title: Indian Heart J
  contributor:
    fullname: Pershad
– volume: 379
  start-page: 2307
  year: 2018
  end-page: 2318
  ident: bb0040
  article-title: Transcatheter mitral-valve repair in patients with heart failure
  publication-title: N Engl J Med
  contributor:
    fullname: Mishell
– volume: 48
  start-page: 647
  year: 1981
  end-page: 654
  ident: bb0020
  article-title: Mitral valve replacement for isolated mitral regurgitation: analysis of clinical course and late postoperative left ventricular ejection fraction
  publication-title: Am J Cardiol
  contributor:
    fullname: Okada
– volume: 64
  start-page: 172
  year: 2014
  end-page: 181
  ident: bb0035
  article-title: Percutaneous mitral valve repair for mitral regurgitation in high-risk patients: results of the EVEREST II study
  publication-title: J Am Coll Cardiol
  contributor:
    fullname: Quesada
– volume: 198
  start-page: 64
  year: 2018
  end-page: 74
  ident: bb0060
  article-title: Comparison of adverse event and device problem rates for transcatheter aortic valve replacement and MitraClip procedures as reported by the transcatheter valve therapy registry and the Food and Drug Administration postmarket surveillance data
  publication-title: Am Heart J
  contributor:
    fullname: Englander
– volume: 32
  start-page: E130
  year: 2020
  end-page: E132
  ident: bb0065
  article-title: The first 4 years of postmarketing safety surveillance related to the MitraClip device: a United States Food and Drug Administration MAUDE experience
  publication-title: J Invasive Cardiol
  contributor:
    fullname: Patel
– volume: 143
  start-page: e72
  year: 2021
  end-page: e227
  ident: bb0045
  article-title: 2020 ACC/AHA guideline for the management of patients with valvular heart disease: a report of the American College of Cardiology/American Heart Association joint committee on clinical practice guidelines
  publication-title: Circulation
  contributor:
    fullname: Gentile
– volume: 68
  start-page: 399
  year: 2016
  ident: 10.1016/j.carrev.2021.09.007_bb0055
  article-title: Percutaneous mitral valve repair: a new treatment for mitral regurgitation
  publication-title: Indian Heart J
  doi: 10.1016/j.ihj.2015.08.025
  contributor:
    fullname: Kelley
– ident: 10.1016/j.carrev.2021.09.007_bb0050
  contributor:
    fullname: MAUDE
– volume: 62
  start-page: 1052
  year: 2013
  ident: 10.1016/j.carrev.2021.09.007_bb0030
  article-title: Percutaneous mitral valve interventions in the real world: early and 1- year results from the ACCESS-EU, a prospective, multicenter, non-randomized post-approval study of the MitraClip therapy in Europe
  publication-title: J Am Coll Cardiol
  doi: 10.1016/j.jacc.2013.02.094
  contributor:
    fullname: Maisano
– volume: 379
  start-page: 2307
  year: 2018
  ident: 10.1016/j.carrev.2021.09.007_bb0040
  article-title: Transcatheter mitral-valve repair in patients with heart failure
  publication-title: N Engl J Med
  doi: 10.1056/NEJMoa1806640
  contributor:
    fullname: Stone
– volume: 14
  start-page: 167
  year: 2013
  ident: 10.1016/j.carrev.2021.09.007_bb0025
  article-title: Joint task force on the Management of Valvular Heart Disease of the European Society of Cardiology (ESC) and the European Association for Cardio-Thoracic Surgery (EACTS)
  publication-title: G Ital Cardiol (Rome)
  contributor:
    fullname: Vahanian
– volume: 198
  start-page: 64
  year: 2018
  ident: 10.1016/j.carrev.2021.09.007_bb0060
  article-title: Comparison of adverse event and device problem rates for transcatheter aortic valve replacement and MitraClip procedures as reported by the transcatheter valve therapy registry and the Food and Drug Administration postmarket surveillance data
  publication-title: Am Heart J
  doi: 10.1016/j.ahj.2017.10.013
  contributor:
    fullname: Benjamin
– volume: 32
  start-page: E130
  year: 2020
  ident: 10.1016/j.carrev.2021.09.007_bb0065
  article-title: The first 4 years of postmarketing safety surveillance related to the MitraClip device: a United States Food and Drug Administration MAUDE experience
  publication-title: J Invasive Cardiol
  contributor:
    fullname: Mahabir
– volume: 48
  start-page: 647
  year: 1981
  ident: 10.1016/j.carrev.2021.09.007_bb0020
  article-title: Mitral valve replacement for isolated mitral regurgitation: analysis of clinical course and late postoperative left ventricular ejection fraction
  publication-title: Am J Cardiol
  doi: 10.1016/0002-9149(81)90142-9
  contributor:
    fullname: Phillips
– volume: 24
  start-page: 1231
  year: 2003
  ident: 10.1016/j.carrev.2021.09.007_bb0015
  article-title: A prospective survey of patients with valvular heart disease in Europe: the euro heart survey on valvular heart disease
  publication-title: Eur Heart J
  doi: 10.1016/S0195-668X(03)00201-X
  contributor:
    fullname: Lung
– volume: 64
  start-page: 172
  year: 2014
  ident: 10.1016/j.carrev.2021.09.007_bb0035
  article-title: Percutaneous mitral valve repair for mitral regurgitation in high-risk patients: results of the EVEREST II study
  publication-title: J Am Coll Cardiol
  doi: 10.1016/j.jacc.2013.12.062
  contributor:
    fullname: Glower
– volume: 373
  start-page: 1382
  year: 2009
  ident: 10.1016/j.carrev.2021.09.007_bb0010
  article-title: Mitral regurgitation
  publication-title: Lancet
  doi: 10.1016/S0140-6736(09)60692-9
  contributor:
    fullname: Enriquez-Sarano
– volume: 143
  start-page: e72
  year: 2021
  ident: 10.1016/j.carrev.2021.09.007_bb0045
  article-title: 2020 ACC/AHA guideline for the management of patients with valvular heart disease: a report of the American College of Cardiology/American Heart Association joint committee on clinical practice guidelines
  publication-title: Circulation
  contributor:
    fullname: Otto
– volume: 368
  start-page: 1005
  year: 2006
  ident: 10.1016/j.carrev.2021.09.007_bb0005
  article-title: Burden of valvular heart diseases: a population-based study
  publication-title: Lancet.
  doi: 10.1016/S0140-6736(06)69208-8
  contributor:
    fullname: Nkomo
SSID ssj0037267
Score 2.3174078
Snippet The MitraClip from Abbott is FDA approved intracardiac implantable device for transcatheter edge-to-edge repair (TEER). Despite a few previously published...
OBJECTIVEThe MitraClip from Abbott is FDA approved intracardiac implantable device for transcatheter edge-to-edge repair (TEER). Despite a few previously...
SourceID pubmedcentral
proquest
crossref
pubmed
elsevier
SourceType Open Access Repository
Aggregation Database
Index Database
Publisher
StartPage 101
SubjectTerms Adverse events
Databases, Factual
Fatal events
Humans
MitraClip
Registries
United States
United States Food and Drug Administration
Title Adverse Events Following Transcatheter Edge-to-Edge Repair (TEER) Using MitraClip: Lessons Learned From the Manufacturer and User Facility Device Experience (MAUDE) Registry
URI https://dx.doi.org/10.1016/j.carrev.2021.09.007
https://www.ncbi.nlm.nih.gov/pubmed/34610901
https://search.proquest.com/docview/2579627972
https://pubmed.ncbi.nlm.nih.gov/PMC10895476
Volume 39
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1Lj9MwELZWi4S4IN6Ux8pIHHYPoYnjxAm3qpuoPLIH2Ep7s2zH3g2CtOoDxIV_xH9kxkkKBSQkTqlSJ7Hy2TOe-JtvCHke56ZOE8thijsWcKfTQLkshyilzjLcp0u94k11ls7m_PVFcnFApkMuDNIqe9vf2XRvrfsz4_5tjpdNM36PFW8y8LcQtIDfzNEO8yTEKgYvvu1oHrFgvoosNg6w9ZA-5zleBumwnyFKZJFXO8Wisn93T38uP39nUf7ilspb5Ga_nqSTrsu3yYFt75DrVb9jfpd89xWX15YWSGxc0xJwX3wBf0W9l_KqrfBqaVFf2mCzCPBIYVWumhU9Pi-KdyfUswpo1cDjpx-b5Uv6FqwjDFbqtVltTcvV4hOF-9BKtVvMlNiu4I6qreFS-FEqgwTcr_TUolmiP9WV6XE1mZ8WJ_DAS1917h6Zl8X5dBb0JRoCw1O-CQwz1kSAqlEQ22jlIlsrp7VzRkMsFjNt4tjysBbYKGQmVyIxoRLWGcFVFN8nh-2itQ8JjeNUKBtFaapz8KxM19wIx7TDsWNzMSLBgIxcdkoccqCofZAdkhKRlGEuAckREQN8cm9ESXAW_7jy2YC2hMmGOyiqtYvtWjLM3GUiF2xEHnTo7_oSe-X6MBqRbG9c7BqgkPf-P21z5QW9ozDLEy7SR__d5cfkBsO8DP956Ak53Ky29imsljb6yE-HI3Jt8urN7OwHPu8Xdg
link.rule.ids 230,314,780,784,885,4502,24116,27924,27925,45585,45679
linkProvider Elsevier
linkToHtml http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1Lj9MwELZWiwRcEO8tTyNx2D2EJrYTJ9xW3UQFmj1AK-3Nsh17CYKk6gPEhX_Ef2TsJIUCEhKnVKmTWJnxPOJvvkHoOc10lcSGwRK3JGBWJYG0aQZZSpWmbp8u8Yw35XkyXbDXF_HFAZoMtTAOVtnb_s6me2vdnxn3b3O8rOvxO9fxJgV_C0kL-M0M7PAVFkP0C0r94tsO50E58W1k3ejADR_q5zzISzs87GdIE0nk6U5dV9m_-6c_48_fYZS_-KXiJrrRB5T4tJvzLXRgmtvoatlvmd9B333L5bXBuUM2rnEBgm-_gMPC3k152lZ4tzivLk2waQN3xBCWy3qFj-d5_vYEe1gBLmt4_ORjvXyJZ2AeQVuxJ2c1FS5W7ScM98GlbLauVGK7gjvKpoJL4UchtUPgfsVnxtkl_JNeGR-Xp4uz_AQeeOnbzt1FiyKfT6ZB36Mh0Cxhm0ATbXQEYtUSkhslbWQqaZWyVitIxihRmlLDwoq7QSHRmeSxDiU3VnMmI3oPHTZtY44QpjTh0kRRkqgMXCtRFdPcEmWd8piMj1AwSEYsOyoOMWDUPohOksJJUoSZAEmOEB_EJ_ZUSoC3-MeVzwZpC1htbgtFNqbdrgVxpbuEZ5yM0P1O-ru5UE9dH0YjlO7pxW6AY_Le_6ep33tG7yhMs5jx5MF_T_kpujadlzMxe3X-5iG6TlyRhv9W9AgdblZb8xhCp4164pfGD6GNGRM
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Adverse+Events+Following+Transcatheter+Edge-to-Edge+Repair+%28TEER%29+Using+MitraClip%3A+Lessons+Learned+From+the+Manufacturer+and+User+Facility+Device+Experience+%28MAUDE%29+Registry&rft.jtitle=Cardiovascular+revascularization+medicine&rft.au=Dodoo%2C+Sheriff+N.&rft.au=Okoh%2C+Alexis+K.&rft.au=Oseni%2C+Abdullahi&rft.au=Odiete%2C+Oghenerukevwe&rft.date=2022-06-01&rft.issn=1553-8389&rft.eissn=1878-0938&rft.volume=39&rft.spage=101&rft.epage=105&rft_id=info:doi/10.1016%2Fj.carrev.2021.09.007&rft_id=info%3Apmid%2F34610901&rft.externalDBID=PMC10895476
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1553-8389&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1553-8389&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1553-8389&client=summon