NIR-II/NIR-I Fluorescence Molecular Tomography of Heterogeneous Mice Based on Gaussian Weighted Neighborhood Fused Lasso Method

Fluorescence molecular tomography (FMT), which can visualize the distribution of fluorescence biomarkers, has become a novel three-dimensional noninvasive imaging technique for in vivo studies such as tumor detection and lymph node location. However, it remains a challenging problem to achieve satis...

Full description

Saved in:
Bibliographic Details
Published inIEEE transactions on medical imaging Vol. 39; no. 6; pp. 2213 - 2222
Main Authors Cai, Meishan, Zhang, Zeyu, Shi, Xiaojing, Hu, Zhenhua, Tian, Jie
Format Journal Article
LanguageEnglish
Published United States IEEE 01.06.2020
The Institute of Electrical and Electronics Engineers, Inc. (IEEE)
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Fluorescence molecular tomography (FMT), which can visualize the distribution of fluorescence biomarkers, has become a novel three-dimensional noninvasive imaging technique for in vivo studies such as tumor detection and lymph node location. However, it remains a challenging problem to achieve satisfactory reconstruction performance of conventional FMT in the first near-infrared window (NIR-I, 700-900nm) because of the severe scattering of NIR-I light. In this study, a promising FMT method for heterogeneous mice was proposed to improve the reconstruction accuracy using the second near-infrared window (NIR-II, 1000-1700nm), where the light scattering significantly reduced compared with NIR-I. The optical properties of NIR-II were analyzed to construct the forward model for NIR-II FMT. Furthermore, to raise the accuracy of solution of the inverse problem, we proposed a novel Gaussian weighted neighborhood fused Lasso (GWNFL) method. Numerical simulation was performed to demonstrate the outperformance of GWNFL compared with other algorithms. Besides, a novel NIR-II/NIR-I dual-modality FMT system was developed to contrast the in vivo reconstruction performance between NIR-II FMT and NIR-I FMT. To compare the reconstruction performance of NIR-II FMT with traditional NIR-I FMT, numerical simulations and in vivo experiments were conducted. Both the simulation and in vivo results showed that NIR-II FMT outperformed NIR-I FMT in terms of location accuracy and spatial overlap index. It is believed that this study could promote the development and biomedical application of NIR-II FMT in the future.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
ISSN:0278-0062
1558-254X
1558-254X
DOI:10.1109/TMI.2020.2964853