Reproducibility of computer-aided detection marks in digital mammography

To evaluate the performance and reproducibility of a computeraided detection (CAD) system in mediolateral oblique (MLO) digital mammograms taken serially, without release of breast compression. A CAD system was applied preoperatively to the fullfield digital mammograms of two MLO views taken without...

Full description

Saved in:
Bibliographic Details
Published inKorean journal of radiology Vol. 8; no. 3; pp. 198 - 205
Main Authors Kim, Seung Ja, Moon, Woo Kyung, Cho, Nariya, Cha, Joo Hee, Kim, Sun Mi, Im, Jung-Gi
Format Journal Article
LanguageEnglish
Published Korea (South) The Korean Society of Radiology 01.05.2007
The Korean Radiological Society
대한영상의학회
Subjects
Online AccessGet full text

Cover

Loading…
Abstract To evaluate the performance and reproducibility of a computeraided detection (CAD) system in mediolateral oblique (MLO) digital mammograms taken serially, without release of breast compression. A CAD system was applied preoperatively to the fullfield digital mammograms of two MLO views taken without release of breast compression in 82 patients (age range: 33-83 years; mean age: 49 years) with previously diagnosed breast cancers. The total number of visible lesion components in 82 patients was 101: 66 masses and 35 microcalcifications. We analyzed the sensitivity and reproducibility of the CAD marks. The sensitivity of the CAD system for first MLO views was 71% (47/66) for masses and 80% (28/35) for microcalcifications. The sensitivity of the CAD system for second MLO views was 68% (45/66) for masses and 17% (6/35) for microcalcifications. In 84 ipsilateral serial MLO image sets (two patients had bilateral cancers), identical images, regardless of the existence of CAD marks, were obtained for 35% (29/84) and identical images with CAD marks were obtained for 29% (23/78). Identical images, regardless of the existence of CAD marks, for contralateral MLO images were 65% (52/80) and identical images with CAD marks were obtained for 28% (11/39). The reproducibility of CAD marks for the true positive masses in serial MLO views was 84% (42/50) and that for the true positive microcalcifications was 0% (0/34). The CAD system in digital mammograms showed a high sensitivity for detecting masses and microcalcifications. However, reproducibility of microcalcification marks was very low in MLO views taken serially without release of breast compression. Minute positional change and patient movement can alter the images and result in a significant effect on the algorithm utilized by the CAD for detecting microcalcifications.
AbstractList To evaluate the performance and reproducibility of a computeraided detection (CAD) system in mediolateral oblique (MLO) digital mammograms taken serially, without release of breast compression. Materials and Methods: A CAD system was applied preoperatively to the fullfield digital mammograms of two MLO views taken without release of breast compression in 82 patients (age range: 33 83 years; mean age: 49 years) with previously diagnosed breast cancers. The total number of visible lesion components in 82 patients was 101: 66 masses and 35 microcalcifications. We analyzed the sensitivity and reproducibility of the CAD marks. Results: The sensitivity of the CAD system for first MLO views was 71% (47/66) for masses and 80% (28/35) for microcalcifications. The sensitivity of the CAD system for second MLO views was 68% (45/66) for masses and 17% (6/35) for microcalcifications. In 84 ipsilateral serial MLO image sets (two patients had bilateral cancers), identical images, regardless of the existence of CAD marks, were obtained for 35% (29/84) and identical images with CAD marks were obtained for 29% (23/78). Identical images, regardless of the existence of CAD marks, for contralateral MLO images were 65% (52/80) and identical images with CAD marks were obtained for 28% (11/39). The reproducibility of CAD marks for the true positive masses in serial MLO views was 84% (42/50) and that for the true positive microcalcifications was 0% (0/34). Conclusion: The CAD system in digital mammograms showed a high sensitivity for detecting masses and microcalcifications. However, reproducibility of microcalcification marks was very low in MLO views taken serially without release of breast compression. Minute positional change and patient movement can alter the images and result in a significant effect on the algorithm utilized by the CAD for detecting microcalcifications. KCI Citation Count: 1
To evaluate the performance and reproducibility of a computeraided detection (CAD) system in mediolateral oblique (MLO) digital mammograms taken serially, without release of breast compression. A CAD system was applied preoperatively to the fullfield digital mammograms of two MLO views taken without release of breast compression in 82 patients (age range: 33-83 years; mean age: 49 years) with previously diagnosed breast cancers. The total number of visible lesion components in 82 patients was 101: 66 masses and 35 microcalcifications. We analyzed the sensitivity and reproducibility of the CAD marks. The sensitivity of the CAD system for first MLO views was 71% (47/66) for masses and 80% (28/35) for microcalcifications. The sensitivity of the CAD system for second MLO views was 68% (45/66) for masses and 17% (6/35) for microcalcifications. In 84 ipsilateral serial MLO image sets (two patients had bilateral cancers), identical images, regardless of the existence of CAD marks, were obtained for 35% (29/84) and identical images with CAD marks were obtained for 29% (23/78). Identical images, regardless of the existence of CAD marks, for contralateral MLO images were 65% (52/80) and identical images with CAD marks were obtained for 28% (11/39). The reproducibility of CAD marks for the true positive masses in serial MLO views was 84% (42/50) and that for the true positive microcalcifications was 0% (0/34). The CAD system in digital mammograms showed a high sensitivity for detecting masses and microcalcifications. However, reproducibility of microcalcification marks was very low in MLO views taken serially without release of breast compression. Minute positional change and patient movement can alter the images and result in a significant effect on the algorithm utilized by the CAD for detecting microcalcifications.
OBJECTIVETo evaluate the performance and reproducibility of a computeraided detection (CAD) system in mediolateral oblique (MLO) digital mammograms taken serially, without release of breast compression.MATERIALS AND METHODSA CAD system was applied preoperatively to the fullfield digital mammograms of two MLO views taken without release of breast compression in 82 patients (age range: 33-83 years; mean age: 49 years) with previously diagnosed breast cancers. The total number of visible lesion components in 82 patients was 101: 66 masses and 35 microcalcifications. We analyzed the sensitivity and reproducibility of the CAD marks.RESULTSThe sensitivity of the CAD system for first MLO views was 71% (47/66) for masses and 80% (28/35) for microcalcifications. The sensitivity of the CAD system for second MLO views was 68% (45/66) for masses and 17% (6/35) for microcalcifications. In 84 ipsilateral serial MLO image sets (two patients had bilateral cancers), identical images, regardless of the existence of CAD marks, were obtained for 35% (29/84) and identical images with CAD marks were obtained for 29% (23/78). Identical images, regardless of the existence of CAD marks, for contralateral MLO images were 65% (52/80) and identical images with CAD marks were obtained for 28% (11/39). The reproducibility of CAD marks for the true positive masses in serial MLO views was 84% (42/50) and that for the true positive microcalcifications was 0% (0/34).CONCLUSIONThe CAD system in digital mammograms showed a high sensitivity for detecting masses and microcalcifications. However, reproducibility of microcalcification marks was very low in MLO views taken serially without release of breast compression. Minute positional change and patient movement can alter the images and result in a significant effect on the algorithm utilized by the CAD for detecting microcalcifications.
Objective To evaluate the performance and reproducibility of a computer-aided detection (CAD) system in mediolateral oblique (MLO) digital mammograms taken serially, without release of breast compression. Materials and Methods A CAD system was applied preoperatively to the full-field digital mammograms of two MLO views taken without release of breast compression in 82 patients (age range: 33 - 83 years; mean age: 49 years) with previously diagnosed breast cancers. The total number of visible lesion components in 82 patients was 101: 66 masses and 35 microcalcifications. We analyzed the sensitivity and reproducibility of the CAD marks. Results The sensitivity of the CAD system for first MLO views was 71% (47/66) for masses and 80% (28/35) for microcalcifications. The sensitivity of the CAD system for second MLO views was 68% (45/66) for masses and 17% (6/35) for microcalcifications. In 84 ipsilateral serial MLO image sets (two patients had bilateral cancers), identical images, regardless of the existence of CAD marks, were obtained for 35% (29/84) and identical images with CAD marks were obtained for 29% (23/78). Identical images, regardless of the existence of CAD marks, for contralateral MLO images were 65% (52/80) and identical images with CAD marks were obtained for 28% (11/39). The reproducibility of CAD marks for the true positive masses in serial MLO views was 84% (42/50) and that for the true positive microcalcifications was 0% (0/34). Conclusion The CAD system in digital mammograms showed a high sensitivity for detecting masses and microcalcifications. However, reproducibility of microcalcification marks was very low in MLO views taken serially without release of breast compression. Minute positional change and patient movement can alter the images and result in a significant effect on the algorithm utilized by the CAD for detecting microcalcifications.
Author Kim, Sun Mi
Cha, Joo Hee
Moon, Woo Kyung
Im, Jung-Gi
Kim, Seung Ja
Cho, Nariya
AuthorAffiliation 2 Department of Radiology, Seoul National University College of Medicine and Clinical Research Institute, Seoul National University Hospital and the Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul 110-744, Korea
1 Department of Radiology, Konkuk University Hospital, Seoul 143-701, Korea
3 Department of Radiology, Boramae Municipal Hospital, Seoul 156-707, Korea
AuthorAffiliation_xml – name: 3 Department of Radiology, Boramae Municipal Hospital, Seoul 156-707, Korea
– name: 1 Department of Radiology, Konkuk University Hospital, Seoul 143-701, Korea
– name: 2 Department of Radiology, Seoul National University College of Medicine and Clinical Research Institute, Seoul National University Hospital and the Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul 110-744, Korea
Author_xml – sequence: 1
  givenname: Seung Ja
  surname: Kim
  fullname: Kim, Seung Ja
  organization: Department of Radiology, Konkuk University Hospital, Seoul, Korea
– sequence: 2
  givenname: Woo Kyung
  surname: Moon
  fullname: Moon, Woo Kyung
– sequence: 3
  givenname: Nariya
  surname: Cho
  fullname: Cho, Nariya
– sequence: 4
  givenname: Joo Hee
  surname: Cha
  fullname: Cha, Joo Hee
– sequence: 5
  givenname: Sun Mi
  surname: Kim
  fullname: Kim, Sun Mi
– sequence: 6
  givenname: Jung-Gi
  surname: Im
  fullname: Im, Jung-Gi
BackLink https://www.ncbi.nlm.nih.gov/pubmed/17554186$$D View this record in MEDLINE/PubMed
https://www.kci.go.kr/kciportal/ci/sereArticleSearch/ciSereArtiView.kci?sereArticleSearchBean.artiId=ART001061817$$DAccess content in National Research Foundation of Korea (NRF)
BookMark eNpdkc1r3DAQxUVJaTZp7z0VQ6H0YkeftnQphNA2gUAgpGchS-ONdm3Jle3A_vfVZpc26WmY0XuPGf3O0EmIARD6SHDFGJcX202qKMZNJStWESXfoFVuRSkZwydoRShVZa2oOkVn07TBmCos-Tt0ShohOJH1Cl3fw5iiW6xvfe_nXRG7wsZhXGZIpfEOXOFgBjv7GIrBpO1U-FA4v_az6fNgGOI6mfFx9x697Uw_wYdjPUe_fnx_uLoub-9-3lxd3paWCzGXpCUtgCUWaKeatmWsASdcDYYTpljHlKudqxXBwvGOC0NsSwx0LQUiaU3YOfp6yA2p01vrdTT-ua6j3iZ9ef9woxtSc7WXfjtIx6UdwFkIczK9HpPPh-yeja9fgn_MMU-a1rThhOeAL8eAFH8vMM168JOFvjcB4jLpBgslmGBZ-Pk_4SYuKeR_0LShkrNasP0--KCyKU5Tgu7vKgTrPU-deeo9Ty0105lntnx6ecI_wxEg-wNgPZ-D
CitedBy_id crossref_primary_10_1016_j_carj_2009_11_010
Cites_doi 10.1118/1.1806291
10.1148/radiol.2203001282
10.1016/S0720-048X(00)00189-3
10.1016/S0009-9260(03)00231-9
10.1007/s00330-001-1213-1
10.1148/radiol.2332031200
10.1148/radiology.215.2.r00ma15554
10.2214/ajr.184.2.01840439
10.1148/radiol.2281020489
ContentType Journal Article
Copyright 2007. This work is published under http://creativecommons.org/licenses/by-nc/3.0 (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.
Copyright © 2007 The Korean Radiological Society 2007
Copyright_xml – notice: 2007. This work is published under http://creativecommons.org/licenses/by-nc/3.0 (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.
– notice: Copyright © 2007 The Korean Radiological Society 2007
DBID CGR
CUY
CVF
ECM
EIF
NPM
AAYXX
CITATION
ABUWG
AFKRA
AZQEC
BENPR
CCPQU
DWQXO
PIMPY
PQEST
PQQKQ
PQUKI
PRINS
7X8
5PM
ACYCR
DOI 10.3348/kjr.2007.8.3.198
DatabaseName Medline
MEDLINE
MEDLINE (Ovid)
MEDLINE
MEDLINE
PubMed
CrossRef
ProQuest Central (Alumni)
ProQuest Central UK/Ireland
ProQuest Central Essentials
AUTh Library subscriptions: ProQuest Central
ProQuest One Community College
ProQuest Central
ProQuest - Publicly Available Content Database
ProQuest One Academic Eastern Edition (DO NOT USE)
ProQuest One Academic
ProQuest One Academic UKI Edition
ProQuest Central China
MEDLINE - Academic
PubMed Central (Full Participant titles)
Korean Citation Index (Open Access)
DatabaseTitle MEDLINE
Medline Complete
MEDLINE with Full Text
PubMed
MEDLINE (Ovid)
CrossRef
Publicly Available Content Database
ProQuest Central
ProQuest One Academic UKI Edition
ProQuest Central Essentials
ProQuest Central Korea
ProQuest One Academic Eastern Edition
ProQuest Central (Alumni Edition)
ProQuest One Community College
ProQuest One Academic
ProQuest Central China
MEDLINE - Academic
DatabaseTitleList
MEDLINE
MEDLINE - Academic
Publicly Available Content Database
Database_xml – sequence: 1
  dbid: NPM
  name: PubMed
  url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed
  sourceTypes: Index Database
– sequence: 2
  dbid: EIF
  name: MEDLINE
  url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search
  sourceTypes: Index Database
– sequence: 3
  dbid: BENPR
  name: AUTh Library subscriptions: ProQuest Central
  url: https://www.proquest.com/central
  sourceTypes: Aggregation Database
DeliveryMethod fulltext_linktorsrc
Discipline Medicine
EISSN 2005-8330
EndPage 205
ExternalDocumentID oai_kci_go_kr_ARTI_716491
10_3348_kjr_2007_8_3_198
17554186
Genre Research Support, Non-U.S. Gov't
Journal Article
GroupedDBID ---
29L
2WC
5-W
53G
5GY
8JR
8XY
9ZL
ADBBV
ADRAZ
AENEX
AFKRA
ALMA_UNASSIGNED_HOLDINGS
AOIJS
BAWUL
BENPR
CCPQU
CGR
CS3
CUY
CVF
DIK
DU5
E3Z
EBD
ECM
EF.
EIF
EMOBN
F5P
FRP
GX1
HYE
KQ8
M48
M~E
NPM
O5R
O5S
OK1
P6G
PGMZT
PIMPY
RNS
RPM
SV3
TR2
W2D
WH7
XSB
AAYXX
CITATION
ABUWG
AZQEC
DWQXO
PQEST
PQQKQ
PQUKI
PRINS
7X8
5PM
ACYCR
ID FETCH-LOGICAL-c455t-1b1beec1ce2f97bb337ed5d6ea41393f39d6dd69105d4f45a1cb1aefb2e182613
IEDL.DBID RPM
ISSN 1229-6929
IngestDate Tue Nov 21 21:31:26 EST 2023
Tue Sep 17 21:22:13 EDT 2024
Thu Aug 15 23:28:39 EDT 2024
Thu Oct 10 16:01:19 EDT 2024
Fri Aug 23 00:47:08 EDT 2024
Sat Sep 28 07:47:59 EDT 2024
IsDoiOpenAccess true
IsOpenAccess true
IsPeerReviewed false
IsScholarly true
Issue 3
Language English
License This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
LinkModel DirectLink
MergedId FETCHMERGED-LOGICAL-c455t-1b1beec1ce2f97bb337ed5d6ea41393f39d6dd69105d4f45a1cb1aefb2e182613
Notes ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
G704-001113.2007.8.3.002
OpenAccessLink https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2627414/
PMID 17554186
PQID 2728436531
PQPubID 5474425
PageCount 8
ParticipantIDs nrf_kci_oai_kci_go_kr_ARTI_716491
pubmedcentral_primary_oai_pubmedcentral_nih_gov_2627414
proquest_miscellaneous_70595353
proquest_journals_2728436531
crossref_primary_10_3348_kjr_2007_8_3_198
pubmed_primary_17554186
PublicationCentury 2000
PublicationDate 2007-05-01
PublicationDateYYYYMMDD 2007-05-01
PublicationDate_xml – month: 05
  year: 2007
  text: 2007-05-01
  day: 01
PublicationDecade 2000
PublicationPlace Korea (South)
PublicationPlace_xml – name: Korea (South)
– name: Seoul
PublicationTitle Korean journal of radiology
PublicationTitleAlternate Korean J Radiol
PublicationYear 2007
Publisher The Korean Society of Radiology
The Korean Radiological Society
대한영상의학회
Publisher_xml – name: The Korean Society of Radiology
– name: The Korean Radiological Society
– name: 대한영상의학회
References 10796939 - Radiology. 2000 May;215(2):554-62
12439584 - Eur Radiol. 2002 Dec;12(12):3015-7
15587648 - Med Phys. 2004 Nov;31(11):2964-72
11091020 - Eur J Radiol. 2000 Dec;36(3):170-4
15671360 - AJR Am J Roentgenol. 2005 Feb;184(2):439-44
11526282 - Radiology. 2001 Sep;220(3):781-6
12943648 - Clin Radiol. 2003 Sep;58(9):733-8
12759470 - Radiology. 2003 Jul;228(1):58-62
15358850 - Radiology. 2004 Nov;233(2):411-7
American College of Radiology (10.3348/kjr.2007.8.3.198_ref7) 1999
American College of Radiology (10.3348/kjr.2007.8.3.198_ref8) 2003
Baker (10.3348/kjr.2007.8.3.198_ref9) 2004; 233
Warren Burhenne (10.3348/kjr.2007.8.3.198_ref1) 2000; 215
Zheng (10.3348/kjr.2007.8.3.198_ref3) 2003; 228
Baum (10.3348/kjr.2007.8.3.198_ref6) 2002; 12
Malich (10.3348/kjr.2007.8.3.198_ref4) 2000; 36
Freer (10.3348/kjr.2007.8.3.198_ref2) 2001; 220
Taylor (10.3348/kjr.2007.8.3.198_ref5) 2003; 58
Zheng (10.3348/kjr.2007.8.3.198_ref11) 2004; 31
Brem (10.3348/kjr.2007.8.3.198_ref10) 2005; 184
References_xml – volume: 31
  start-page: 2964
  year: 2004
  ident: 10.3348/kjr.2007.8.3.198_ref11
  publication-title: Med Phys
  doi: 10.1118/1.1806291
  contributor:
    fullname: Zheng
– volume: 220
  start-page: 781
  year: 2001
  ident: 10.3348/kjr.2007.8.3.198_ref2
  publication-title: Radiology
  doi: 10.1148/radiol.2203001282
  contributor:
    fullname: Freer
– volume: 36
  start-page: 170
  year: 2000
  ident: 10.3348/kjr.2007.8.3.198_ref4
  publication-title: Eur J Radiol
  doi: 10.1016/S0720-048X(00)00189-3
  contributor:
    fullname: Malich
– volume: 58
  start-page: 733
  year: 2003
  ident: 10.3348/kjr.2007.8.3.198_ref5
  publication-title: Clin Radiol
  doi: 10.1016/S0009-9260(03)00231-9
  contributor:
    fullname: Taylor
– volume: 12
  start-page: 3015
  year: 2002
  ident: 10.3348/kjr.2007.8.3.198_ref6
  publication-title: Eur Radiol
  doi: 10.1007/s00330-001-1213-1
  contributor:
    fullname: Baum
– volume: 233
  start-page: 411
  year: 2004
  ident: 10.3348/kjr.2007.8.3.198_ref9
  publication-title: Radiology
  doi: 10.1148/radiol.2332031200
  contributor:
    fullname: Baker
– volume-title: Breast imaging reporting and data system: BI-RADS atlas
  year: 2003
  ident: 10.3348/kjr.2007.8.3.198_ref8
  contributor:
    fullname: American College of Radiology
– volume: 215
  start-page: 554
  year: 2000
  ident: 10.3348/kjr.2007.8.3.198_ref1
  publication-title: Radiology
  doi: 10.1148/radiology.215.2.r00ma15554
  contributor:
    fullname: Warren Burhenne
– volume: 184
  start-page: 439
  year: 2005
  ident: 10.3348/kjr.2007.8.3.198_ref10
  publication-title: AJR Am J Roentgenol
  doi: 10.2214/ajr.184.2.01840439
  contributor:
    fullname: Brem
– volume: 228
  start-page: 58
  year: 2003
  ident: 10.3348/kjr.2007.8.3.198_ref3
  publication-title: Radiology
  doi: 10.1148/radiol.2281020489
  contributor:
    fullname: Zheng
– start-page: 284
  volume-title: Mammography quality control manual
  year: 1999
  ident: 10.3348/kjr.2007.8.3.198_ref7
  contributor:
    fullname: American College of Radiology
SSID ssj0029084
Score 1.7697443
Snippet To evaluate the performance and reproducibility of a computeraided detection (CAD) system in mediolateral oblique (MLO) digital mammograms taken serially,...
Objective To evaluate the performance and reproducibility of a computer-aided detection (CAD) system in mediolateral oblique (MLO) digital mammograms taken...
OBJECTIVETo evaluate the performance and reproducibility of a computeraided detection (CAD) system in mediolateral oblique (MLO) digital mammograms taken...
SourceID nrf
pubmedcentral
proquest
crossref
pubmed
SourceType Open Website
Open Access Repository
Aggregation Database
Index Database
StartPage 198
SubjectTerms Adult
Aged
Aged, 80 and over
Breast cancer
Breast Neoplasms - diagnostic imaging
Calcification
Calcinosis - diagnostic imaging
False Positive Reactions
Female
Humans
Mammography
Mammography - methods
Middle Aged
Original
Patients
Performance evaluation
Radiographic Image Interpretation, Computer-Assisted
Reproducibility
Reproducibility of Results
Sensitivity and Specificity
Ultrasonic imaging
방사선과학
SummonAdditionalLinks – databaseName: AUTh Library subscriptions: ProQuest Central
  dbid: BENPR
  link: http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwfV1Nb9QwEB3RrYS4IL5JKRAkLhzSru3YTk6o0FYLEhVCVOrN8se4hJWSdnd74N8zTrJbFiEuiRTn4Mw49nue8TyAtx6jEl5Y4iaaLhItzYNTT5ynFCIowiS-z7Y4U7Pz8vOFvBg33JZjWuV6Tuwn6tD5tEd-yDVNpELRkHl_dV0k1agUXR0lNHZglxNTmE5g98PJ2ddvG8pVT3vNYcZTkgchgSFQmU6fHs5_LoYKhtWBOCDqvbUw7bSL-C_M-Xfq5B9r0ekDuD-CyPxo8PpDuIPtI7j7ZQyTP4YZweq-kuuQ-vor72K-lm8ojpqAIT_GVZ-E1ebptM4yb9r8uLlMCiL0gD52KGT9BM5PT75_nBWjZELhSylXBXPMIXrmkcdaOyeExiCDQkuLVS2iqIMKQRFGkKGMpbTMO2YxOo6JaDDxFCZt1-JzyCtE65R3gltfli5azadR8Ao1gRTHbQbv1vYyV0NlDEOMItnWkG2TvqU2lRGGbJvBGzKomfvGpHLW6X7ZmfnCEGj_ZBJlq1kG-2tzm_E_Wppbr2fwetNMf0AKa9gWu5ul0YQQpZAig2eDb267owkssUploLe8tnkhdWa7pW1-9DW2ea9JVO79v1Mv4N6w15sSIPdhslrc4EsCKSv3ahyJvwEskuds
  priority: 102
  providerName: ProQuest
– databaseName: Scholars Portal Journals: Open Access
  dbid: M48
  link: http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1Lb9QwELZokRAXVN6hBYLEhcMu61ecHCpUUaoFqZxYqTfLj3EbFmUhu5Xov-9Mkt22aE9cEinOwxqPPd9kxvMx9j5AKmSQDn0TgwcNDtfBSUCfR0kZC8Qkocu2-F5MZ-rbmT672R49CHC51bUjPqlZ-2v898_VJ5zwh-RxSlV-nP9s-1qE5ViO0YneYffpS0TkcKo2MQVRTTr-YS4o4QNRQR-03PoGKiVq0NBy2mJ9y17tNG3aBkX_zai8ZaJO9tijAVvmR70yPGb3oHnCHpwO0fOnbIpouyvw2mfEXuWLlK9ZHUZHdYSYH8Oqy81qctrEs8zrJj-uz4lYBC-gyvb1rZ-x2cmXH5-no4FJYRSU1qsR99wDBB5ApMp4L6WBqGMBDm1YJZOsYhFjgdBBR5WUdjx47iB5AeR_cPmc7TaLBl6yvARwvgheCheU8skZMUlSlGAQu3jhMvZhLS_7uy-YYdHRIDFbFDPRXhpbWmlRzBl7hwK181BbqnJN5_OFnbcWsfxXS55cxTN2sBa3XWuHFQatqixw_cjY200zTgyKdrgGFpdLaxA4aqllxl70Y3PTnWFoM2bujNrmBurM3ZamvuhKb4uOqki9-u8n99nD_u8wpUwesN1VewmvEdas_JtOW68BquP2nA
  priority: 102
  providerName: Scholars Portal
Title Reproducibility of computer-aided detection marks in digital mammography
URI https://www.ncbi.nlm.nih.gov/pubmed/17554186
https://www.proquest.com/docview/2728436531
https://search.proquest.com/docview/70595353
https://pubmed.ncbi.nlm.nih.gov/PMC2627414
https://www.kci.go.kr/kciportal/ci/sereArticleSearch/ciSereArtiView.kci?sereArticleSearchBean.artiId=ART001061817
Volume 8
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
ispartofPNX Korean Journal of Radiology, 2007, 8(3), , pp.198-205
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1La9wwEB6yKZReStOn22TrQi897EMvyz6mebAtbAilgdyEXk7cbbRhd3Pov-9ItvOip15ssGwQo7Hn-6xvZgA-W18XzDKN3ETiQXiN38GpRc7DGXMFYhKb1BYnxeyMfz8X51sg-lyYJNq3phmH31fj0FwmbeX1lZ30OrHJ6fyApoYxfDKAATpoT9E7llVNU5thQqOuA4N_uzcZE04ni1-rtmhhOWZjZNuxYqjEeEpiJvW9sDQIq_pfiPOxcPJeJDp-Ac87CJnvt1PdgS0fXsLTebdJ_gpmCKpTHddW-PonX9Z537xhtN847_JDv0kSrJDHXJ113oT8sLmI_UPwAnpmW8b6NZwdH_08mI26hgkjy4XYjIghxntLrKd1JY1hTHonXOE1hqqK1axyhXMFIgTheM2FJtYQ7WtDfaQZhL2B7bAM_h3kpffaFNYwqi3nptaSTmtGSy8RohiqM_jS20tdt3UxFPKJaGaFZo7dLaUqFVNo5gw-oUHVwjYqFrOO54ulWqwUQvZvKhK2imSw25tbdW_RWlGJwZMV-JnI4OPtMPp_3NTQwS9v1koiPhRMsAzetmtzN51uaTOQD1bt9oY4mYcj6HCpwnbnYO__-8kP8Kz9CRyVkbuwvVnd-D1ELxszhCdfj05OfwxhMOflMPnuX9Ic8XQ
link.rule.ids 230,315,730,783,787,888,2228,21400,24330,27936,27937,33756,33757,43817,53804,53806,74630
linkProvider National Library of Medicine
linkToHtml http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwfV1Nb9QwEB3RVoJeEN8ECg0SFw5p13ZiJydUaKsttCuEWqk3yx_jElZK2t3tgX_POMluWYS4JFKcgzPj2O95xvMA3jsMUjhhiJsouhRoaB4cOeI8uRBeEiZxXbbFRI4v8i-XxeWw4TYf0iqXc2I3UfvWxT3yfa5oIhWShszH65ssqkbF6OogobEBW7FUFZGvrU9Hk2_fV5SrGnWaw4zHJA9CAn2gMp4-3Z_-nPUVDMs9sUfUe21h2mhm4V-Y8-_UyT_WouNH8HAAkelB7_XHcA-bJ3D_bAiTP4Uxwequkmuf-vorbUO6lG_IDmqPPj3ERZeE1aTxtM48rZv0sL6KCiL0gD62L2T9DC6Oj84_j7NBMiFzeVEsMmaZRXTMIQ-VslYIhb7wEg0tVpUIovLSe0kYofB5yAvDnGUGg-UYiQYTz2GzaRt8CWmJaKx0VnDj8twGo_goCF6iIpBiuUngw9Je-rqvjKGJUUTbarJt1LdUutRCk20TeEcG1VNX61jOOt6vWj2daQLtJzpStoolsLM0tx7-o7m-83oCu6tm-gNiWMM02N7OtSKEWIhCJPCi981ddxSBJVbKBNSa11YvxM6stzT1j67GNu80ifJX_-_ULjwYn5-d6tOTydfXsN3v-8ZkyB3YXMxu8Q0BloV9O4zK30-k6mY
linkToPdf http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwfV1Lb9QwEB7RrVRxQZRnoKVB4sIh3XUc28kJlW5XWx6rClGpN8vPElZKyu72wL9nnHi3XYS4JFKcgzMe2994vswH8M44z6mhCmMTgRfmFK6DI4MxT0Gp5YhJTMe2mPHpZfHpil1F_tMy0irXa2K3UNvWhDPyYS5wIaUcXWboIy3iYjz5cPMrCwpSIdMa5TR2YFcUnI4GsPvxbHbxbRN-VaNOf5jkgfCBqKBPWoY_UYfzn4u-mmF5TI8xDN_apHaahf8X_vybRnlvX5o8hkcRUKYnvQfswwPXPIG9rzFl_hSmCLG7qq49DfZ32vp0LeWQndTW2XTsVh0hq0nDnzvLtG7ScX0d1ETwAX5sX9T6GVxOzr6fTrMon5CZgrFVRjTRzhliXO4roTWlwllmuVO4cVXU08pyazniBWYLXzBFjCbKeZ27EHQQ-hwGTdu4l5CWzinNjaa5MkWhvRL5yNO8dAIBi85VAu_X9pI3fZUMidFFsK1E2watSyFLSSXaNoG3aFA5N7UMpa3D_bqV84VEAH8uQ_hWkQQO1uaWcU4t5Z0HJHC0acbZEFIcqnHt7VIKRIuMMprAi35s7rojEDiRkicgtkZt80LozHZLU__o6m3nnT5R8er_nTqCPXRI-eV89vk1POyPgAMv8gAGq8WtO0TsstJvolP-AR3N7pQ
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Reproducibility+of+Computer-Aided+Detection+Marks+in+Digital+Mammography&rft.jtitle=Korean+journal+of+radiology&rft.au=Kim%2C+Seung+Ja&rft.au=Moon%2C+Woo+Kyung&rft.au=Cho%2C+Nariya&rft.au=Cha%2C+Joo+Hee&rft.date=2007-05-01&rft.pub=The+Korean+Radiological+Society&rft.issn=1229-6929&rft.eissn=2005-8330&rft.volume=8&rft.issue=3&rft.spage=198&rft.epage=205&rft_id=info:doi/10.3348%2Fkjr.2007.8.3.198&rft_id=info%3Apmid%2F17554186&rft.externalDBID=PMC2627414
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1229-6929&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1229-6929&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1229-6929&client=summon