Endosuture aneurysm repair in patients treated with Endurant II/IIs in conjunction with Heli-FX EndoAnchor implants for short-neck abdominal aortic aneurysm
AbstractObjectiveEndovascular repair of abdominal aortic aneurysm (AAA) remains a challenging clinical scenario when there is a short or nonexistent segment of healthy infrarenal aorta. This study sought to determine the safety and effectiveness of endosuture aneurysm repair (ESAR) using the Enduran...
Saved in:
Published in | Journal of vascular surgery Vol. 70; no. 3; pp. 732 - 740 |
---|---|
Main Authors | , , , , , , , , |
Format | Journal Article |
Language | English |
Published |
United States
Elsevier Inc
01.09.2019
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Abstract | AbstractObjectiveEndovascular repair of abdominal aortic aneurysm (AAA) remains a challenging clinical scenario when there is a short or nonexistent segment of healthy infrarenal aorta. This study sought to determine the safety and effectiveness of endosuture aneurysm repair (ESAR) using the Endurant II/IIs endograft (Medtronic Vascular, Santa Rosa, Calif) in conjunction with Heli-FX EndoAnchors (Medtronic Vascular) in the treatment of short-neck AAA. MethodsIn this subgroup analysis, 70 patients were identified from the Aneurysm Treatment Using the Heli-FX EndoAnchor System Global Registry (ANCHOR) who had an infrarenal neck length <10 mm down to 4 mm based on core laboratory measurements. Primary outcomes included technical success of the index procedure, rate of type IA endoleak at 1 month and 12 months, and rate of secondary procedures at 12 months. ResultsIn this short-neck cohort (n = 70), the average neck length and diameter were 6.9 ± 1.6 mm and 25.7 ± 4.0 mm, respectively. Investigators reported an overall procedural success rate of 97.1% and a technical success rate of 88.6%. The duration of the implant procedure, EndoAnchor implantation, and total fluoroscopy time was 148.0 ± 80.0 minutes, 17.1 ± 11.5 minutes, and 35.3 ± 22.0 minutes, respectively, and an average of 5.5 ± 2.1 EndoAnchors were implanted per patient. Through the 30-day follow-up, type IA endoleaks were reported in four patients, of which three resolved spontaneously by the 12-month follow-up. There was an additional type IA endoleak through the 12-month follow-up that has not resulted in AAA enlargement or required a secondary procedure. The Kaplan-Meier estimate for freedom from secondary endovascular procedures and all-cause mortality is 95.4% and 92.7% through 365 days, respectively. No patient in the short-neck cohort experienced main body stent migration, increase in maximum aneurysm diameter, or aneurysm rupture or required conversion to open surgical repair through 12 months. ConclusionsIn this analysis of the short-neck cohort from ANCHOR, the Endurant II/IIs endograft in conjunction with Heli-FX EndoAnchor implants (ESAR) appears to be a safe and effective treatment option with a high technical success rate and low incidence of type IA endoleaks and secondary interventions. Despite the complex and hostile anatomies, the ESAR method required short procedure and fluoroscopy times. These short-term outcomes suggest that ESAR could be complementary to therapies currently available for treatment of hostile AAA anatomy and a viable off-the-shelf endovascular treatment option for patients with short-neck AAAs, although long-term follow-up is critically important. |
---|---|
AbstractList | AbstractObjectiveEndovascular repair of abdominal aortic aneurysm (AAA) remains a challenging clinical scenario when there is a short or nonexistent segment of healthy infrarenal aorta. This study sought to determine the safety and effectiveness of endosuture aneurysm repair (ESAR) using the Endurant II/IIs endograft (Medtronic Vascular, Santa Rosa, Calif) in conjunction with Heli-FX EndoAnchors (Medtronic Vascular) in the treatment of short-neck AAA. MethodsIn this subgroup analysis, 70 patients were identified from the Aneurysm Treatment Using the Heli-FX EndoAnchor System Global Registry (ANCHOR) who had an infrarenal neck length <10 mm down to 4 mm based on core laboratory measurements. Primary outcomes included technical success of the index procedure, rate of type IA endoleak at 1 month and 12 months, and rate of secondary procedures at 12 months. ResultsIn this short-neck cohort (n = 70), the average neck length and diameter were 6.9 ± 1.6 mm and 25.7 ± 4.0 mm, respectively. Investigators reported an overall procedural success rate of 97.1% and a technical success rate of 88.6%. The duration of the implant procedure, EndoAnchor implantation, and total fluoroscopy time was 148.0 ± 80.0 minutes, 17.1 ± 11.5 minutes, and 35.3 ± 22.0 minutes, respectively, and an average of 5.5 ± 2.1 EndoAnchors were implanted per patient. Through the 30-day follow-up, type IA endoleaks were reported in four patients, of which three resolved spontaneously by the 12-month follow-up. There was an additional type IA endoleak through the 12-month follow-up that has not resulted in AAA enlargement or required a secondary procedure. The Kaplan-Meier estimate for freedom from secondary endovascular procedures and all-cause mortality is 95.4% and 92.7% through 365 days, respectively. No patient in the short-neck cohort experienced main body stent migration, increase in maximum aneurysm diameter, or aneurysm rupture or required conversion to open surgical repair through 12 months. ConclusionsIn this analysis of the short-neck cohort from ANCHOR, the Endurant II/IIs endograft in conjunction with Heli-FX EndoAnchor implants (ESAR) appears to be a safe and effective treatment option with a high technical success rate and low incidence of type IA endoleaks and secondary interventions. Despite the complex and hostile anatomies, the ESAR method required short procedure and fluoroscopy times. These short-term outcomes suggest that ESAR could be complementary to therapies currently available for treatment of hostile AAA anatomy and a viable off-the-shelf endovascular treatment option for patients with short-neck AAAs, although long-term follow-up is critically important. OBJECTIVEEndovascular repair of abdominal aortic aneurysm (AAA) remains a challenging clinical scenario when there is a short or nonexistent segment of healthy infrarenal aorta. This study sought to determine the safety and effectiveness of endosuture aneurysm repair (ESAR) using the Endurant II/IIs endograft (Medtronic Vascular, Santa Rosa, Calif) in conjunction with Heli-FX EndoAnchors (Medtronic Vascular) in the treatment of short-neck AAA. METHODSIn this subgroup analysis, 70 patients were identified from the Aneurysm Treatment Using the Heli-FX EndoAnchor System Global Registry (ANCHOR) who had an infrarenal neck length <10 mm down to 4 mm based on core laboratory measurements. Primary outcomes included technical success of the index procedure, rate of type IA endoleak at 1 month and 12 months, and rate of secondary procedures at 12 months. RESULTSIn this short-neck cohort (n = 70), the average neck length and diameter were 6.9 ± 1.6 mm and 25.7 ± 4.0 mm, respectively. Investigators reported an overall procedural success rate of 97.1% and a technical success rate of 88.6%. The duration of the implant procedure, EndoAnchor implantation, and total fluoroscopy time was 148.0 ± 80.0 minutes, 17.1 ± 11.5 minutes, and 35.3 ± 22.0 minutes, respectively, and an average of 5.5 ± 2.1 EndoAnchors were implanted per patient. Through the 30-day follow-up, type IA endoleaks were reported in four patients, of which three resolved spontaneously by the 12-month follow-up. There was an additional type IA endoleak through the 12-month follow-up that has not resulted in AAA enlargement or required a secondary procedure. The Kaplan-Meier estimate for freedom from secondary endovascular procedures and all-cause mortality is 95.4% and 92.7% through 365 days, respectively. No patient in the short-neck cohort experienced main body stent migration, increase in maximum aneurysm diameter, or aneurysm rupture or required conversion to open surgical repair through 12 months. CONCLUSIONSIn this analysis of the short-neck cohort from ANCHOR, the Endurant II/IIs endograft in conjunction with Heli-FX EndoAnchor implants (ESAR) appears to be a safe and effective treatment option with a high technical success rate and low incidence of type IA endoleaks and secondary interventions. Despite the complex and hostile anatomies, the ESAR method required short procedure and fluoroscopy times. These short-term outcomes suggest that ESAR could be complementary to therapies currently available for treatment of hostile AAA anatomy and a viable off-the-shelf endovascular treatment option for patients with short-neck AAAs, although long-term follow-up is critically important. Endovascular repair of abdominal aortic aneurysm (AAA) remains a challenging clinical scenario when there is a short or nonexistent segment of healthy infrarenal aorta. This study sought to determine the safety and effectiveness of endosuture aneurysm repair (ESAR) using the Endurant II/IIs endograft (Medtronic Vascular, Santa Rosa, Calif) in conjunction with Heli-FX EndoAnchors (Medtronic Vascular) in the treatment of short-neck AAA. In this subgroup analysis, 70 patients were identified from the Aneurysm Treatment Using the Heli-FX EndoAnchor System Global Registry (ANCHOR) who had an infrarenal neck length <10 mm down to 4 mm based on core laboratory measurements. Primary outcomes included technical success of the index procedure, rate of type IA endoleak at 1 month and 12 months, and rate of secondary procedures at 12 months. In this short-neck cohort (n = 70), the average neck length and diameter were 6.9 ± 1.6 mm and 25.7 ± 4.0 mm, respectively. Investigators reported an overall procedural success rate of 97.1% and a technical success rate of 88.6%. The duration of the implant procedure, EndoAnchor implantation, and total fluoroscopy time was 148.0 ± 80.0 minutes, 17.1 ± 11.5 minutes, and 35.3 ± 22.0 minutes, respectively, and an average of 5.5 ± 2.1 EndoAnchors were implanted per patient. Through the 30-day follow-up, type IA endoleaks were reported in four patients, of which three resolved spontaneously by the 12-month follow-up. There was an additional type IA endoleak through the 12-month follow-up that has not resulted in AAA enlargement or required a secondary procedure. The Kaplan-Meier estimate for freedom from secondary endovascular procedures and all-cause mortality is 95.4% and 92.7% through 365 days, respectively. No patient in the short-neck cohort experienced main body stent migration, increase in maximum aneurysm diameter, or aneurysm rupture or required conversion to open surgical repair through 12 months. In this analysis of the short-neck cohort from ANCHOR, the Endurant II/IIs endograft in conjunction with Heli-FX EndoAnchor implants (ESAR) appears to be a safe and effective treatment option with a high technical success rate and low incidence of type IA endoleaks and secondary interventions. Despite the complex and hostile anatomies, the ESAR method required short procedure and fluoroscopy times. These short-term outcomes suggest that ESAR could be complementary to therapies currently available for treatment of hostile AAA anatomy and a viable off-the-shelf endovascular treatment option for patients with short-neck AAAs, although long-term follow-up is critically important. |
Author | Arko, Frank R., MD Fugate, Mark W., MD Pearce, Benjamin J., MD Garrett, H. Edward, MD Mehta, Manish, MD, MPH Torsello, Giovanni, MD, PhD Panneton, Jean M., MD, FRCSC, FACS Stanley, Gregory A., MD Henretta, John P., MD |
Author_xml | – sequence: 1 fullname: Arko, Frank R., MD – sequence: 2 fullname: Stanley, Gregory A., MD – sequence: 3 fullname: Pearce, Benjamin J., MD – sequence: 4 fullname: Henretta, John P., MD – sequence: 5 fullname: Fugate, Mark W., MD – sequence: 6 fullname: Mehta, Manish, MD, MPH – sequence: 7 fullname: Torsello, Giovanni, MD, PhD – sequence: 8 fullname: Panneton, Jean M., MD, FRCSC, FACS – sequence: 9 fullname: Garrett, H. Edward, MD |
BackLink | https://www.ncbi.nlm.nih.gov/pubmed/30850297$$D View this record in MEDLINE/PubMed |
BookMark | eNp9ks1q3TAQhUVJaW7SPkA3Rctu7Mz43xQKISSNIdBFW-hOyPJcIseWXElOuO_Sh63MTbPooish8Z3D6Jw5YyfGGmLsPUKKgNXFmI6PPs0AmxQxhTx_xXYIbZ1UDbQnbAd1gUmZYXHKzrwfARDLpn7DTnNoSsjaesd-X5vB-jWsjrg0tLqDn7mjRWrHteGLDJpM8Dw4koEG_qTDPY-a1UkTeNdddJ3fQGXNuBoVtDVH5pYmndz83Fh7adS9jX7zMsnNbB8vPr6ExJB64LIf7KyNnLiMb1q9DPKWvd7LydO75_Oc_bi5_n51m9x9_dJdXd4lqigxJFRXZVU2ssxUnUmkGjOkYdiDBISs76XsqwFlG5PJ27rIQVEMRuVUyCavoc7P2cej7-Lsr5V8ELP2iqY4LdnViwybtiyxaCCieESVs9472ovF6Vm6g0AQWyliFLEUsZUiEEUsJWo-PNuv_UzDi-JvCxH4dAQofvJRkxNexdgVDdqRCmKw-r_2n_9Rq0kbreT0QAfyo11dzNYLFD4TIL5tW7EtBbY5QNyU_A8wSbYJ |
CitedBy_id | crossref_primary_10_1177_02841851211019806 crossref_primary_10_1177_1708538120923417 crossref_primary_10_17116_hirurgia2019111100 crossref_primary_10_1016_j_jvs_2021_07_122 crossref_primary_10_1590_1677_5449_202300402 crossref_primary_10_3389_fsurg_2022_872705 crossref_primary_10_1080_17434440_2023_2221787 crossref_primary_10_1097_CM9_0000000000002352 crossref_primary_10_1016_j_ejvs_2023_11_002 crossref_primary_10_23736_S0021_9509_20_11248_5 crossref_primary_10_1177_1708538120958837 crossref_primary_10_3390_jpm12071018 crossref_primary_10_1016_j_ejvs_2021_07_019 crossref_primary_10_1007_s00270_020_02488_4 crossref_primary_10_1177_17085381221097304 crossref_primary_10_1016_j_avsg_2024_01_002 crossref_primary_10_1080_17434440_2020_1841629 crossref_primary_10_1016_j_jvs_2020_04_508 crossref_primary_10_1016_j_jvs_2022_08_035 crossref_primary_10_1016_j_jvscit_2022_11_002 crossref_primary_10_1016_j_jvs_2023_07_058 crossref_primary_10_1007_s00117_022_01018_2 crossref_primary_10_1177_1708538121992596 crossref_primary_10_1016_j_jvs_2021_01_047 crossref_primary_10_1177_15266028231212131 |
Cites_doi | 10.1016/j.ejvs.2015.04.028 10.1016/j.jvs.2013.07.009 10.1016/j.jvs.2013.08.005 10.1016/j.jvs.2008.11.060 10.1016/j.ejvs.2013.03.027 10.1177/152660280701400502 10.1016/j.jvs.2014.04.063 10.1016/j.jvs.2014.03.255 10.1016/j.jvs.2011.03.002 10.1016/j.jvs.2014.01.036 10.1177/1457496913490464 10.1583/08-2531.1 10.1177/152660280100800102 10.1583/1545-1550-20.2.159 10.1016/j.jvs.2012.11.039 10.1016/j.jvs.2014.10.085 10.1038/srep20497 10.1016/j.jvs.2014.04.038 10.1016/j.jvs.2010.12.062 10.1016/j.jvs.2012.09.050 10.1583/06-1882.1 10.1016/j.jvs.2011.01.067 10.1016/j.jvs.2013.10.104 10.1016/j.ejvs.2012.07.005 10.1016/j.jvs.2014.03.295 10.1016/j.ejvs.2010.01.004 |
ContentType | Journal Article |
Copyright | The Authors 2019 The Authors Copyright © 2019 The Authors. Published by Elsevier Inc. All rights reserved. |
Copyright_xml | – notice: The Authors – notice: 2019 The Authors – notice: Copyright © 2019 The Authors. Published by Elsevier Inc. All rights reserved. |
DBID | 6I. AAFTH CGR CUY CVF ECM EIF NPM AAYXX CITATION 7X8 |
DOI | 10.1016/j.jvs.2018.11.033 |
DatabaseName | ScienceDirect Open Access Titles Elsevier:ScienceDirect:Open Access Medline MEDLINE MEDLINE (Ovid) MEDLINE MEDLINE PubMed CrossRef MEDLINE - Academic |
DatabaseTitle | MEDLINE Medline Complete MEDLINE with Full Text PubMed MEDLINE (Ovid) CrossRef MEDLINE - Academic |
DatabaseTitleList | MEDLINE - Academic MEDLINE |
Database_xml | – sequence: 1 dbid: NPM name: PubMed url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed sourceTypes: Index Database – sequence: 2 dbid: EIF name: MEDLINE url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search sourceTypes: Index Database |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Medicine |
EISSN | 1097-6809 |
EndPage | 740 |
ExternalDocumentID | 10_1016_j_jvs_2018_11_033 30850297 S0741521419300680 1_s2_0_S0741521419300680 |
Genre | Research Support, Non-U.S. Gov't Journal Article |
GroupedDBID | --- --K .1- .55 .FO .GJ .XZ 0R~ 0SF 1B1 1P~ 1~5 2WC 354 4.4 457 4G. 53G 5GY 5RE 5VS 6I. 7-5 AACTN AAEDT AAEDW AAFTH AAIKJ AALRI AAQFI AAQXK AAXUO ABFRF ABJNI ABLJU ABMAC ABOCM ABVKL ACGFO ACGFS ACPHU ADBBV ADEZE ADMUD ADPAM ADVLN AEFWE AENEX AEVXI AEXQZ AFCTW AFFNX AFJKZ AFRHN AFTJW AGHFR AITUG AJUYK AKRWK ALMA_UNASSIGNED_HOLDINGS AMRAJ ASPBG AVWKF AZFZN BAWUL BELOY C45 C5W CAG COF CS3 DIK DU5 E3Z EBS EFJIC EJD FDB FEDTE FGOYB FRP GBLVA HVGLF HZ~ IHE IXB J1W J5H K-O KOM L7B M41 MO0 N4W NCXOZ NQ- O-L O9- OB2 OBH OHH OK- OK1 OVD OW- OZT P2P R2- RIG ROL RPZ SDG SDP SEL SES SEW SJN SSZ TEORI UHS UV1 VVN W2D X7M XH2 YFH YOC Z5R ZGI ZXP ZY1 AAIAV AGZHU AHPSJ ALXNB ZA5 CGR CUY CVF ECM EIF NPM AAYXX CITATION 7X8 |
ID | FETCH-LOGICAL-c451t-e765658a52c72a1e7121eddf0a0102bbaab6d1a9097397430ce741c3e4a837073 |
IEDL.DBID | ABVKL |
ISSN | 0741-5214 |
IngestDate | Fri Aug 16 09:54:22 EDT 2024 Thu Sep 26 16:34:22 EDT 2024 Sat Sep 28 08:31:31 EDT 2024 Fri Feb 23 02:23:51 EST 2024 Tue Oct 15 22:56:10 EDT 2024 |
IsDoiOpenAccess | true |
IsOpenAccess | true |
IsPeerReviewed | true |
IsScholarly | true |
Issue | 3 |
Keywords | Endosuture aneurysm repair EVAR EndoAnchor fEVAR chEVAR |
Language | English |
License | This is an open access article under the CC BY-NC-ND license. Copyright © 2019 The Authors. Published by Elsevier Inc. All rights reserved. |
LinkModel | DirectLink |
MergedId | FETCHMERGED-LOGICAL-c451t-e765658a52c72a1e7121eddf0a0102bbaab6d1a9097397430ce741c3e4a837073 |
Notes | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
OpenAccessLink | https://www.sciencedirect.com/science/article/pii/S0741521419300680 |
PMID | 30850297 |
PQID | 2189551480 |
PQPubID | 23479 |
PageCount | 9 |
ParticipantIDs | proquest_miscellaneous_2189551480 crossref_primary_10_1016_j_jvs_2018_11_033 pubmed_primary_30850297 elsevier_sciencedirect_doi_10_1016_j_jvs_2018_11_033 elsevier_clinicalkeyesjournals_1_s2_0_S0741521419300680 |
PublicationCentury | 2000 |
PublicationDate | 2019-09-01 |
PublicationDateYYYYMMDD | 2019-09-01 |
PublicationDate_xml | – month: 09 year: 2019 text: 2019-09-01 day: 01 |
PublicationDecade | 2010 |
PublicationPlace | United States |
PublicationPlace_xml | – name: United States |
PublicationTitle | Journal of vascular surgery |
PublicationTitleAlternate | J Vasc Surg |
PublicationYear | 2019 |
Publisher | Elsevier Inc |
Publisher_xml | – name: Elsevier Inc |
References | Stokmans, Teijink, Forbes, Bockler, Peeters, Riambau (bib14) 2012; 44 Makaroun, Tuchek, Massop, Henretta, Rhee, Buckley (bib12) 2011; 54 Anderson, Berce, Hartley (bib10) 2001; 8 Lee, Ullery, Zarins, Olcott, Harris, Dalman (bib1) 2013; 46 Lee, Lee, Chandra, Dalman (bib6) 2014; 60 Lo, Lu, Fokkema, Conrad, Patel, Fillinger (bib19) 2014; 59 (bib7) 2009; 9 Suominen, Pimenoff, Salenius (bib20) 2013; 102 Ziegler, Avgerinos, Umscheid, Perdikides, Stelter (bib21) 2007; 14 Jordan, Mehta, Varnagy, Moore, Arko, Joye (bib11) 2014; 60 Mendes, Oderich, Macedo, Pereira, Cha, Duncan (bib4) 2014; 60 Bockler, Fitridge, Wolf, Hayes, Silveira, Numan (bib13) 2010; 51 Katsargyris, Oikonomou, Klonaris, Topel, Verhoeven (bib17) 2013; 20 Banno, Cochennec, Marzelle, Becquemin (bib5) 2014; 60 Leurs, Kievit, Dagnelie, Nelemans, Buth (bib2) 2006; 13 Chisci, Kristmundsson, de Donato, Resch, Setacci, Sonesson (bib16) 2009; 16 Grimme, Zeebregts, Verhoeven, Bekkema, Reijnen, Tielliu (bib28) 2014; 59 Antoniou, Georgiadis, Antoniou, Kuhan, Murray (bib3) 2013; 57 Coscas, Kobeiter, Desgranges, Becquemin (bib22) 2011; 53 Kristmundsson, Sonesson, Dias, Törnqvist, Malina, Resch (bib24) 2014; 59 Lo, Bensley, Hamdan, Wyers, Adams, Schermerhorn (bib18) 2013; 57 Verhoeven, Vourliotakis, Bos, Tielliu, Zeebregts, Prins (bib25) 2010; 39 Shahverdyan, Majd, Thul, Braun, Gawenda, Brunkwall (bib9) 2015; 50 Torsello, Troisi, Donas, Austermann (bib15) 2011; 54 O'Callaghan, Greenberg, Eagleton, Bena, Mastracci (bib23) 2015; 61 Li, Hu, Bai, Liu, Zhang, Ge (bib26) 2016; 6 Scali, Feezor, Chang, Waterman, Berceli, Huber (bib27) 2014; 60 Hiramoto, Chang, Reilly, Schneider, Rapp, Chuter (bib8) 2009; 49 Banno (10.1016/j.jvs.2018.11.033_bib5) 2014; 60 Hiramoto (10.1016/j.jvs.2018.11.033_bib8) 2009; 49 Ziegler (10.1016/j.jvs.2018.11.033_bib21) 2007; 14 Coscas (10.1016/j.jvs.2018.11.033_bib22) 2011; 53 Bockler (10.1016/j.jvs.2018.11.033_bib13) 2010; 51 Torsello (10.1016/j.jvs.2018.11.033_bib15) 2011; 54 Lo (10.1016/j.jvs.2018.11.033_bib18) 2013; 57 Scali (10.1016/j.jvs.2018.11.033_bib27) 2014; 60 Kristmundsson (10.1016/j.jvs.2018.11.033_bib24) 2014; 59 Li (10.1016/j.jvs.2018.11.033_bib26) 2016; 6 Shahverdyan (10.1016/j.jvs.2018.11.033_bib9) 2015; 50 Stokmans (10.1016/j.jvs.2018.11.033_bib14) 2012; 44 Lo (10.1016/j.jvs.2018.11.033_bib19) 2014; 59 Lee (10.1016/j.jvs.2018.11.033_bib1) 2013; 46 O'Callaghan (10.1016/j.jvs.2018.11.033_bib23) 2015; 61 Katsargyris (10.1016/j.jvs.2018.11.033_bib17) 2013; 20 Verhoeven (10.1016/j.jvs.2018.11.033_bib25) 2010; 39 Leurs (10.1016/j.jvs.2018.11.033_bib2) 2006; 13 Lee (10.1016/j.jvs.2018.11.033_bib6) 2014; 60 Mendes (10.1016/j.jvs.2018.11.033_bib4) 2014; 60 Grimme (10.1016/j.jvs.2018.11.033_bib28) 2014; 59 Suominen (10.1016/j.jvs.2018.11.033_bib20) 2013; 102 Antoniou (10.1016/j.jvs.2018.11.033_bib3) 2013; 57 Jordan (10.1016/j.jvs.2018.11.033_bib11) 2014; 60 (10.1016/j.jvs.2018.11.033_bib7) 2009; 9 Anderson (10.1016/j.jvs.2018.11.033_bib10) 2001; 8 Makaroun (10.1016/j.jvs.2018.11.033_bib12) 2011; 54 Chisci (10.1016/j.jvs.2018.11.033_bib16) 2009; 16 |
References_xml | – volume: 50 start-page: 432 year: 2015 end-page: 441 ident: bib9 article-title: F-EVAR does not impair renal function more than open surgery for juxtarenal aortic aneurysms: single centre results publication-title: Eur J Vasc Endovasc Surg contributor: fullname: Brunkwall – volume: 49 start-page: 1100 year: 2009 end-page: 1106 ident: bib8 article-title: Outcome of renal stenting for renal artery coverage during endovascular aortic aneurysm repair publication-title: J Vasc Surg contributor: fullname: Chuter – volume: 60 start-page: 31 year: 2014 end-page: 39 ident: bib5 article-title: Comparison of fenestrated endovascular aneurysm repair and chimney graft techniques for pararenal aortic aneurysm publication-title: J Vasc Surg contributor: fullname: Becquemin – volume: 102 start-page: 182 year: 2013 end-page: 188 ident: bib20 article-title: Fenestrated and chimney endografts for juxtarenal aneurysms: early and midterm results publication-title: Scand J Surg contributor: fullname: Salenius – volume: 9 start-page: 1 year: 2009 end-page: 51 ident: bib7 article-title: Fenestrated endovascular grafts for the repair of juxtarenal aortic aneurysms: an evidence-based analysis publication-title: Ont Health Technol Assess Ser – volume: 16 start-page: 137 year: 2009 end-page: 146 ident: bib16 article-title: The AAA with a challenging neck: outcome of open versus endovascular repair with standard and fenestrated stent-grafts publication-title: J Endovasc Ther contributor: fullname: Sonesson – volume: 14 start-page: 609 year: 2007 end-page: 618 ident: bib21 article-title: Fenestrated endografting for aortic aneurysm repair: a 7-year experience publication-title: J Endovasc Ther contributor: fullname: Stelter – volume: 57 start-page: 1261 year: 2013 end-page: 1268 ident: bib18 article-title: Gender differences in abdominal aortic aneurysm presentation, repair, and mortality in the Vascular Study Group of New England publication-title: J Vasc Surg contributor: fullname: Schermerhorn – volume: 60 start-page: 885 year: 2014 end-page: 892.e2 ident: bib11 article-title: Results of the ANCHOR prospective, multicenter registry of EndoAnchors for type Ia endoleaks and endograft migration in patients with challenging anatomy publication-title: J Vasc Surg contributor: fullname: Joye – volume: 60 start-page: 849 year: 2014 end-page: 856 ident: bib6 article-title: Comparison of fenestrated endografts and the snorkel/chimney technique publication-title: J Vasc Surg contributor: fullname: Dalman – volume: 6 start-page: 20497 year: 2016 ident: bib26 article-title: Fenestrated and chimney technique for juxtarenal aortic aneurysm: a systematic review and pooled data analysis publication-title: Sci Rep contributor: fullname: Ge – volume: 46 start-page: 65 year: 2013 end-page: 73 ident: bib1 article-title: EVAR deployment in anatomically challenging necks outside the IFU publication-title: Eur J Vasc Endovasc Surg contributor: fullname: Dalman – volume: 13 start-page: 640 year: 2006 end-page: 648 ident: bib2 article-title: Influence of infrarenal neck length on outcome of endovascular abdominal aortic aneurysm repair publication-title: J Endovasc Ther contributor: fullname: Buth – volume: 57 start-page: 527 year: 2013 end-page: 538 ident: bib3 article-title: A meta-analysis of outcomes of endovascular abdominal aortic aneurysm repair in patients with hostile and friendly neck anatomy publication-title: J Vasc Surg contributor: fullname: Murray – volume: 39 start-page: 529 year: 2010 end-page: 536 ident: bib25 article-title: Fenestrated stent grafting for short-necked and juxtarenal abdominal aortic aneurysm: an 8-year single-centre experience publication-title: Eur J Vasc Endovasc Surg contributor: fullname: Prins – volume: 59 start-page: 115 year: 2014 end-page: 120 ident: bib24 article-title: Outcomes of fenestrated endovascular repair of juxtarenal aortic aneurysm publication-title: J Vasc Surg contributor: fullname: Resch – volume: 8 start-page: 3 year: 2001 end-page: 15 ident: bib10 article-title: Endoluminal aortic grafting with renal and superior mesenteric artery incorporation by graft fenestration publication-title: J Endovasc Ther contributor: fullname: Hartley – volume: 20 start-page: 159 year: 2013 end-page: 169 ident: bib17 article-title: Comparison of outcomes with open, fenestrated, and chimney graft repair of juxtarenal aneurysms: are we ready for a paradigm shift? publication-title: J Endovasc Ther contributor: fullname: Verhoeven – volume: 60 start-page: 839 year: 2014 end-page: 847 ident: bib4 article-title: Anatomic feasibility of off-the-shelf fenestrated stent grafts to treat juxtarenal and pararenal abdominal aortic aneurysms publication-title: J Vasc Surg contributor: fullname: Duncan – volume: 60 start-page: 865 year: 2014 end-page: 874.e1 ident: bib27 article-title: Critical analysis of results after chimney EVAR raises cause for concern publication-title: J Vasc Surg contributor: fullname: Huber – volume: 54 start-page: 300 year: 2011 end-page: 306 ident: bib15 article-title: Evaluation of the Endurant stent graft under instructions for use vs off-label conditions for endovascular aortic aneurysm repair publication-title: J Vasc Surg contributor: fullname: Austermann – volume: 59 start-page: 298 year: 2014 end-page: 306 ident: bib28 article-title: Visceral stent patency in fenestrated stent grafting for abdominal aortic aneurysm repair publication-title: J Vasc Surg contributor: fullname: Tielliu – volume: 59 start-page: 1209 year: 2014 end-page: 1216 ident: bib19 article-title: Relative importance of aneurysm diameter and body size for predicting abdominal aortic aneurysm rupture in men and women publication-title: J Vasc Surg contributor: fullname: Fillinger – volume: 61 start-page: 908 year: 2015 end-page: 914 ident: bib23 article-title: Type Ia endoleaks after fenestrated and branched endografts may lead to component instability and increased aortic mortality publication-title: J Vasc Surg contributor: fullname: Mastracci – volume: 51 start-page: 481 year: 2010 end-page: 491 ident: bib13 article-title: Rationale and design of the Endurant Stent Graft Natural Selection Global Postmarket Registry (ENGAGE): interim analysis at 30 days of the first 180 patients enrolled publication-title: J Cardiovasc Surg (Torino) contributor: fullname: Numan – volume: 44 start-page: 369 year: 2012 end-page: 375 ident: bib14 article-title: Early results from the ENGAGE registry: real-world performance of the Endurant Stent Graft for endovascular AAA repair in 1262 patients publication-title: Eur J Vasc Endovasc Surg contributor: fullname: Riambau – volume: 53 start-page: 1520 year: 2011 end-page: 1527 ident: bib22 article-title: Technical aspects, current indications, and results of chimney grafts for juxtarenal aortic aneurysms publication-title: J Vasc Surg contributor: fullname: Becquemin – volume: 54 start-page: 601 year: 2011 end-page: 608 ident: bib12 article-title: One year outcomes of the United States regulatory trial of the Endurant Stent Graft System publication-title: J Vasc Surg contributor: fullname: Buckley – volume: 50 start-page: 432 year: 2015 ident: 10.1016/j.jvs.2018.11.033_bib9 article-title: F-EVAR does not impair renal function more than open surgery for juxtarenal aortic aneurysms: single centre results publication-title: Eur J Vasc Endovasc Surg doi: 10.1016/j.ejvs.2015.04.028 contributor: fullname: Shahverdyan – volume: 59 start-page: 115 year: 2014 ident: 10.1016/j.jvs.2018.11.033_bib24 article-title: Outcomes of fenestrated endovascular repair of juxtarenal aortic aneurysm publication-title: J Vasc Surg doi: 10.1016/j.jvs.2013.07.009 contributor: fullname: Kristmundsson – volume: 59 start-page: 298 year: 2014 ident: 10.1016/j.jvs.2018.11.033_bib28 article-title: Visceral stent patency in fenestrated stent grafting for abdominal aortic aneurysm repair publication-title: J Vasc Surg doi: 10.1016/j.jvs.2013.08.005 contributor: fullname: Grimme – volume: 49 start-page: 1100 year: 2009 ident: 10.1016/j.jvs.2018.11.033_bib8 article-title: Outcome of renal stenting for renal artery coverage during endovascular aortic aneurysm repair publication-title: J Vasc Surg doi: 10.1016/j.jvs.2008.11.060 contributor: fullname: Hiramoto – volume: 46 start-page: 65 year: 2013 ident: 10.1016/j.jvs.2018.11.033_bib1 article-title: EVAR deployment in anatomically challenging necks outside the IFU publication-title: Eur J Vasc Endovasc Surg doi: 10.1016/j.ejvs.2013.03.027 contributor: fullname: Lee – volume: 14 start-page: 609 year: 2007 ident: 10.1016/j.jvs.2018.11.033_bib21 article-title: Fenestrated endografting for aortic aneurysm repair: a 7-year experience publication-title: J Endovasc Ther doi: 10.1177/152660280701400502 contributor: fullname: Ziegler – volume: 60 start-page: 885 year: 2014 ident: 10.1016/j.jvs.2018.11.033_bib11 article-title: Results of the ANCHOR prospective, multicenter registry of EndoAnchors for type Ia endoleaks and endograft migration in patients with challenging anatomy publication-title: J Vasc Surg doi: 10.1016/j.jvs.2014.04.063 contributor: fullname: Jordan – volume: 60 start-page: 849 year: 2014 ident: 10.1016/j.jvs.2018.11.033_bib6 article-title: Comparison of fenestrated endografts and the snorkel/chimney technique publication-title: J Vasc Surg doi: 10.1016/j.jvs.2014.03.255 contributor: fullname: Lee – volume: 51 start-page: 481 year: 2010 ident: 10.1016/j.jvs.2018.11.033_bib13 article-title: Rationale and design of the Endurant Stent Graft Natural Selection Global Postmarket Registry (ENGAGE): interim analysis at 30 days of the first 180 patients enrolled publication-title: J Cardiovasc Surg (Torino) contributor: fullname: Bockler – volume: 54 start-page: 601 year: 2011 ident: 10.1016/j.jvs.2018.11.033_bib12 article-title: One year outcomes of the United States regulatory trial of the Endurant Stent Graft System publication-title: J Vasc Surg doi: 10.1016/j.jvs.2011.03.002 contributor: fullname: Makaroun – volume: 60 start-page: 31 year: 2014 ident: 10.1016/j.jvs.2018.11.033_bib5 article-title: Comparison of fenestrated endovascular aneurysm repair and chimney graft techniques for pararenal aortic aneurysm publication-title: J Vasc Surg doi: 10.1016/j.jvs.2014.01.036 contributor: fullname: Banno – volume: 102 start-page: 182 year: 2013 ident: 10.1016/j.jvs.2018.11.033_bib20 article-title: Fenestrated and chimney endografts for juxtarenal aneurysms: early and midterm results publication-title: Scand J Surg doi: 10.1177/1457496913490464 contributor: fullname: Suominen – volume: 9 start-page: 1 year: 2009 ident: 10.1016/j.jvs.2018.11.033_bib7 article-title: Fenestrated endovascular grafts for the repair of juxtarenal aortic aneurysms: an evidence-based analysis publication-title: Ont Health Technol Assess Ser – volume: 16 start-page: 137 year: 2009 ident: 10.1016/j.jvs.2018.11.033_bib16 article-title: The AAA with a challenging neck: outcome of open versus endovascular repair with standard and fenestrated stent-grafts publication-title: J Endovasc Ther doi: 10.1583/08-2531.1 contributor: fullname: Chisci – volume: 8 start-page: 3 year: 2001 ident: 10.1016/j.jvs.2018.11.033_bib10 article-title: Endoluminal aortic grafting with renal and superior mesenteric artery incorporation by graft fenestration publication-title: J Endovasc Ther doi: 10.1177/152660280100800102 contributor: fullname: Anderson – volume: 20 start-page: 159 year: 2013 ident: 10.1016/j.jvs.2018.11.033_bib17 article-title: Comparison of outcomes with open, fenestrated, and chimney graft repair of juxtarenal aneurysms: are we ready for a paradigm shift? publication-title: J Endovasc Ther doi: 10.1583/1545-1550-20.2.159 contributor: fullname: Katsargyris – volume: 57 start-page: 1261 year: 2013 ident: 10.1016/j.jvs.2018.11.033_bib18 article-title: Gender differences in abdominal aortic aneurysm presentation, repair, and mortality in the Vascular Study Group of New England publication-title: J Vasc Surg doi: 10.1016/j.jvs.2012.11.039 contributor: fullname: Lo – volume: 61 start-page: 908 year: 2015 ident: 10.1016/j.jvs.2018.11.033_bib23 article-title: Type Ia endoleaks after fenestrated and branched endografts may lead to component instability and increased aortic mortality publication-title: J Vasc Surg doi: 10.1016/j.jvs.2014.10.085 contributor: fullname: O'Callaghan – volume: 6 start-page: 20497 year: 2016 ident: 10.1016/j.jvs.2018.11.033_bib26 article-title: Fenestrated and chimney technique for juxtarenal aortic aneurysm: a systematic review and pooled data analysis publication-title: Sci Rep doi: 10.1038/srep20497 contributor: fullname: Li – volume: 60 start-page: 839 year: 2014 ident: 10.1016/j.jvs.2018.11.033_bib4 article-title: Anatomic feasibility of off-the-shelf fenestrated stent grafts to treat juxtarenal and pararenal abdominal aortic aneurysms publication-title: J Vasc Surg doi: 10.1016/j.jvs.2014.04.038 contributor: fullname: Mendes – volume: 54 start-page: 300 year: 2011 ident: 10.1016/j.jvs.2018.11.033_bib15 article-title: Evaluation of the Endurant stent graft under instructions for use vs off-label conditions for endovascular aortic aneurysm repair publication-title: J Vasc Surg doi: 10.1016/j.jvs.2010.12.062 contributor: fullname: Torsello – volume: 57 start-page: 527 year: 2013 ident: 10.1016/j.jvs.2018.11.033_bib3 article-title: A meta-analysis of outcomes of endovascular abdominal aortic aneurysm repair in patients with hostile and friendly neck anatomy publication-title: J Vasc Surg doi: 10.1016/j.jvs.2012.09.050 contributor: fullname: Antoniou – volume: 13 start-page: 640 year: 2006 ident: 10.1016/j.jvs.2018.11.033_bib2 article-title: Influence of infrarenal neck length on outcome of endovascular abdominal aortic aneurysm repair publication-title: J Endovasc Ther doi: 10.1583/06-1882.1 contributor: fullname: Leurs – volume: 53 start-page: 1520 year: 2011 ident: 10.1016/j.jvs.2018.11.033_bib22 article-title: Technical aspects, current indications, and results of chimney grafts for juxtarenal aortic aneurysms publication-title: J Vasc Surg doi: 10.1016/j.jvs.2011.01.067 contributor: fullname: Coscas – volume: 59 start-page: 1209 year: 2014 ident: 10.1016/j.jvs.2018.11.033_bib19 article-title: Relative importance of aneurysm diameter and body size for predicting abdominal aortic aneurysm rupture in men and women publication-title: J Vasc Surg doi: 10.1016/j.jvs.2013.10.104 contributor: fullname: Lo – volume: 44 start-page: 369 year: 2012 ident: 10.1016/j.jvs.2018.11.033_bib14 article-title: Early results from the ENGAGE registry: real-world performance of the Endurant Stent Graft for endovascular AAA repair in 1262 patients publication-title: Eur J Vasc Endovasc Surg doi: 10.1016/j.ejvs.2012.07.005 contributor: fullname: Stokmans – volume: 60 start-page: 865 year: 2014 ident: 10.1016/j.jvs.2018.11.033_bib27 article-title: Critical analysis of results after chimney EVAR raises cause for concern publication-title: J Vasc Surg doi: 10.1016/j.jvs.2014.03.295 contributor: fullname: Scali – volume: 39 start-page: 529 year: 2010 ident: 10.1016/j.jvs.2018.11.033_bib25 article-title: Fenestrated stent grafting for short-necked and juxtarenal abdominal aortic aneurysm: an 8-year single-centre experience publication-title: Eur J Vasc Endovasc Surg doi: 10.1016/j.ejvs.2010.01.004 contributor: fullname: Verhoeven |
SSID | ssj0011587 |
Score | 2.477929 |
Snippet | AbstractObjectiveEndovascular repair of abdominal aortic aneurysm (AAA) remains a challenging clinical scenario when there is a short or nonexistent segment of... Endovascular repair of abdominal aortic aneurysm (AAA) remains a challenging clinical scenario when there is a short or nonexistent segment of healthy... OBJECTIVEEndovascular repair of abdominal aortic aneurysm (AAA) remains a challenging clinical scenario when there is a short or nonexistent segment of healthy... |
SourceID | proquest crossref pubmed elsevier |
SourceType | Aggregation Database Index Database Publisher |
StartPage | 732 |
SubjectTerms | Aged Aged, 80 and over Aorta, Abdominal - diagnostic imaging Aorta, Abdominal - surgery Aortic Aneurysm, Abdominal - diagnostic imaging Aortic Aneurysm, Abdominal - surgery Blood Vessel Prosthesis Blood Vessel Prosthesis Implantation - adverse effects Blood Vessel Prosthesis Implantation - instrumentation chEVAR EndoAnchor Endoleak - etiology Endosuture aneurysm repair Endovascular Procedures - adverse effects Endovascular Procedures - instrumentation EVAR Female fEVAR Humans Male Middle Aged Prosthesis Design Retrospective Studies Surgery Suture Techniques - adverse effects Suture Techniques - instrumentation Sutures Time Factors Treatment Outcome |
Title | Endosuture aneurysm repair in patients treated with Endurant II/IIs in conjunction with Heli-FX EndoAnchor implants for short-neck abdominal aortic aneurysm |
URI | https://www.clinicalkey.es/playcontent/1-s2.0-S0741521419300680 https://dx.doi.org/10.1016/j.jvs.2018.11.033 https://www.ncbi.nlm.nih.gov/pubmed/30850297 https://search.proquest.com/docview/2189551480 |
Volume | 70 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1Nb9QwELXarYS4oPK90FZG4oRkNk4cOzluq64aoFygaG-WE3ulLDRZbbJI_Bd-LDOOs1KFyoFjrHFiecbzxpnxMyFvM1hAojQpi21eMoiII5bxlWBJKo1Lpapyheedrz_LqxvxYZkuD8jFeBYGyyqD7x98uvfWoWUWZnO2qevZFw-GMRcQgvgbJA7JUYxppgk5mp9_-_hpn0zgqb8nD-UZdhiTm77Ma_0TSbt59h65PJPkPni6L_z0MLQ4Jo9C_EjnwxAfkwPXPCEPrkOG_Cn5fdnYtvNEIdQgWeWv7pZuAXPqLa0bGmhUO-oLzJ2l-B-WQp8dYFZPi2JWFB0KwjZ5DZCHahtkAJ9qtliibDtvwGnC-243P7CMhkLgSzto6Vnjqu_UlLb1d4VR0-I49wN5Rm4Wl18vrli4gYFVIuU9cwrCvTQzaVyp2HCneMydtavIIBVdWRpTSstNjpw_sDFJosrBJFeJEwZJdVTynEyatnEvCZUyXuUSj8FKK1ZSGBcpJ1QJOxRASG6n5N048XozEG3osQJtrUFLGrUEGxYNWpoSNapGjydIwee5LizATnPdxTrSfxnJlIh9zzt2pgFC_vXBN6MBaFh_mFSBqWt3IMSzHKNOfPWLwTL240-QDzDO1av_--hr8hCeQkXbCZn02507hRCoL8-CiZ-Rw2J5_gc1DwUs |
link.rule.ids | 315,786,790,3525,27600,27955,27956,45696,45907 |
linkProvider | Elsevier |
linkToHtml | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV3Pb9MwFLbGJgEXNH6NwgAjcUIyjRPHTo5lWtWwdhc21JvlxK6UwpKqSZH4X_hjeS9xKk3TOHBNnxPL7_l9n-vnz4R8TGACidzELLRpzoARByzhK8GiWBoXS1WkCs87Ly7l7Fp8XcbLA3I2nIXBskqf-_uc3mVr_2TsR3O8Kcvxtw4MQy6AgnQ3SDwgR8AGUgjzo8mX7xfz_WYCj7t78tCeYYNhc7Mr81r_QtFunnxGLc8oug-e7qOfHQxNj8kTzx_ppO_iU3Lgqmfk4cLvkD8nf84rWzedUAg1KFb5u7mhW8CcckvLinoZ1YZ2BebOUvwflkKbHWBWS7NsnGUNGsIyeQ2Qh27rbQCfSjZdom09qSBpwvtuNj-xjIYC8aUNPGlZ5Yof1OS27u4Ko6bGfu478oJcT8-vzmbM38DAChHzljkFdC9OTBwWKjTcKR5yZ-0qMChFl-fG5NJyk6LmDyxMoqBwMMhF5IRBUR0VvSSHVV25V4RKGa5SicdgpRUrKYwLlBMqhxUKICS3I_JpGHi96YU29FCBttbgJY1eggWLBi-NiBpco4cTpJDzXOMnYKO5bkId6DtBMiJi3_JWnGmAkH998MMQABrmH26qwNDVOzDiSYqsE1990kfGvv8R6gGGqXr9fx99Tx7NrhZzPc8uL96Qx_CLr247JYftdufeAh1q83c-3P8Cl1sHIQ |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Endosuture+aneurysm+repair+in+patients+treated+with+Endurant+II%2FIIs+in+conjunction+with+Heli-FX+EndoAnchor+implants+for+short-neck+abdominal+aortic+aneurysm&rft.jtitle=Journal+of+vascular+surgery&rft.au=Arko%2C+Frank+R.&rft.au=Stanley%2C+Gregory+A.&rft.au=Pearce%2C+Benjamin+J.&rft.au=Henretta%2C+John+P.&rft.date=2019-09-01&rft.pub=Elsevier+Inc&rft.issn=0741-5214&rft.eissn=1097-6809&rft.volume=70&rft.issue=3&rft.spage=732&rft.epage=740&rft_id=info:doi/10.1016%2Fj.jvs.2018.11.033&rft.externalDocID=S0741521419300680 |
thumbnail_m | http://utb.summon.serialssolutions.com/2.0.0/image/custom?url=https%3A%2F%2Fcdn.clinicalkey.com%2Fck-thumbnails%2F07415214%2FS0741521419X00099%2Fcov150h.gif |