Kinematic analysis of the human body during sit-to-stand in healthy young adults
Sit-to-stand (STS) motion is one of the most important and energy-consuming basic motions in everyday life. Kinematic analysis provides information regarding what strategy or motion pattern is used by the healthy people, and through which, we can understand and obtain the law of the STS motion. The...
Saved in:
Published in | Medicine (Baltimore) Vol. 100; no. 22; p. e26208 |
---|---|
Main Authors | , , , , , , |
Format | Journal Article |
Language | English |
Published |
United States
Lippincott Williams & Wilkins
04.06.2021
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Abstract | Sit-to-stand (STS) motion is one of the most important and energy-consuming basic motions in everyday life. Kinematic analysis provides information regarding what strategy or motion pattern is used by the healthy people, and through which, we can understand and obtain the law of the STS motion. The objective of this article is to study the law of STS motion through the experiment to determine a suitable description of STS motion in healthy adults, so as to provide a starting point and bases for future design and control of STS assistive devices.Thirty healthy adult subjects participated in this study and carried out STS motion experiment of standing up naturally. The STS motions were recorded using a high-definition camera. The experimentally collected kinematic data and a link segment model of the human body were used to obtain the coordinates of joints and to calculate the coordinates, velocity, and momentum of center of gravity; the postures of human body during STS are also obtained. The relationship between human body parameters and motion parameters is analyzed by using Pearson correlation method.The STS motion is divided into 4 phases; the phases are differentiated in terms of STS motion characteristics and postures, and momentum of center of gravity of human body. The main factors determining the differences in STS motion among individuals are horizontal distance between hip joint and ankle joint, lower leg length, thigh length, and the length of the transition period. The horizontal distance between hip joint and ankle joint is positively correlated with the duration from motion begin to trunk stops flexing forward (P = .021 < .05), but not so with the duration from motion begin to the end of phase 2 (P = .15 > .05).The results suggest that when designing the sit-to-stand assistive devices, one should pay attention to the whole-body posture control in STS motion, such as the posture guidance of trunk and lower leg, and should carry out specific training according to different STS phases. Sit-to-stand assistive devices should provide the same horizontal distance between hip joint and ankle joint for different individuals during the STS motion. Transition period should be properly controlled, and the degree of freedom of the lower leg should not be limited. |
---|---|
AbstractList | Sit-to-stand (STS) motion is one of the most important and energy-consuming basic motions in everyday life. Kinematic analysis provides information regarding what strategy or motion pattern is used by the healthy people, and through which, we can understand and obtain the law of the STS motion. The objective of this article is to study the law of STS motion through the experiment to determine a suitable description of STS motion in healthy adults, so as to provide a starting point and bases for future design and control of STS assistive devices.Thirty healthy adult subjects participated in this study and carried out STS motion experiment of standing up naturally. The STS motions were recorded using a high-definition camera. The experimentally collected kinematic data and a link segment model of the human body were used to obtain the coordinates of joints and to calculate the coordinates, velocity, and momentum of center of gravity; the postures of human body during STS are also obtained. The relationship between human body parameters and motion parameters is analyzed by using Pearson correlation method.The STS motion is divided into 4 phases; the phases are differentiated in terms of STS motion characteristics and postures, and momentum of center of gravity of human body. The main factors determining the differences in STS motion among individuals are horizontal distance between hip joint and ankle joint, lower leg length, thigh length, and the length of the transition period. The horizontal distance between hip joint and ankle joint is positively correlated with the duration from motion begin to trunk stops flexing forward (P = .021 < .05), but not so with the duration from motion begin to the end of phase 2 (P = .15 > .05).The results suggest that when designing the sit-to-stand assistive devices, one should pay attention to the whole-body posture control in STS motion, such as the posture guidance of trunk and lower leg, and should carry out specific training according to different STS phases. Sit-to-stand assistive devices should provide the same horizontal distance between hip joint and ankle joint for different individuals during the STS motion. Transition period should be properly controlled, and the degree of freedom of the lower leg should not be limited. Sit-to-stand (STS) motion is one of the most important and energy-consuming basic motions in everyday life. Kinematic analysis provides information regarding what strategy or motion pattern is used by the healthy people, and through which, we can understand and obtain the law of the STS motion. The objective of this article is to study the law of STS motion through the experiment to determine a suitable description of STS motion in healthy adults, so as to provide a starting point and bases for future design and control of STS assistive devices.Thirty healthy adult subjects participated in this study and carried out STS motion experiment of standing up naturally. The STS motions were recorded using a high-definition camera. The experimentally collected kinematic data and a link segment model of the human body were used to obtain the coordinates of joints and to calculate the coordinates, velocity, and momentum of center of gravity; the postures of human body during STS are also obtained. The relationship between human body parameters and motion parameters is analyzed by using Pearson correlation method.The STS motion is divided into 4 phases; the phases are differentiated in terms of STS motion characteristics and postures, and momentum of center of gravity of human body. The main factors determining the differences in STS motion among individuals are horizontal distance between hip joint and ankle joint, lower leg length, thigh length, and the length of the transition period. The horizontal distance between hip joint and ankle joint is positively correlated with the duration from motion begin to trunk stops flexing forward (P = .021 < .05), but not so with the duration from motion begin to the end of phase 2 (P = .15 > .05).The results suggest that when designing the sit-to-stand assistive devices, one should pay attention to the whole-body posture control in STS motion, such as the posture guidance of trunk and lower leg, and should carry out specific training according to different STS phases. Sit-to-stand assistive devices should provide the same horizontal distance between hip joint and ankle joint for different individuals during the STS motion. Transition period should be properly controlled, and the degree of freedom of the lower leg should not be limited.ABSTRACTSit-to-stand (STS) motion is one of the most important and energy-consuming basic motions in everyday life. Kinematic analysis provides information regarding what strategy or motion pattern is used by the healthy people, and through which, we can understand and obtain the law of the STS motion. The objective of this article is to study the law of STS motion through the experiment to determine a suitable description of STS motion in healthy adults, so as to provide a starting point and bases for future design and control of STS assistive devices.Thirty healthy adult subjects participated in this study and carried out STS motion experiment of standing up naturally. The STS motions were recorded using a high-definition camera. The experimentally collected kinematic data and a link segment model of the human body were used to obtain the coordinates of joints and to calculate the coordinates, velocity, and momentum of center of gravity; the postures of human body during STS are also obtained. The relationship between human body parameters and motion parameters is analyzed by using Pearson correlation method.The STS motion is divided into 4 phases; the phases are differentiated in terms of STS motion characteristics and postures, and momentum of center of gravity of human body. The main factors determining the differences in STS motion among individuals are horizontal distance between hip joint and ankle joint, lower leg length, thigh length, and the length of the transition period. The horizontal distance between hip joint and ankle joint is positively correlated with the duration from motion begin to trunk stops flexing forward (P = .021 < .05), but not so with the duration from motion begin to the end of phase 2 (P = .15 > .05).The results suggest that when designing the sit-to-stand assistive devices, one should pay attention to the whole-body posture control in STS motion, such as the posture guidance of trunk and lower leg, and should carry out specific training according to different STS phases. Sit-to-stand assistive devices should provide the same horizontal distance between hip joint and ankle joint for different individuals during the STS motion. Transition period should be properly controlled, and the degree of freedom of the lower leg should not be limited. Sit-to-stand (STS) motion is one of the most important and energy-consuming basic motions in everyday life. Kinematic analysis provides information regarding what strategy or motion pattern is used by the healthy people, and through which, we can understand and obtain the law of the STS motion. The objective of this article is to study the law of STS motion through the experiment to determine a suitable description of STS motion in healthy adults, so as to provide a starting point and bases for future design and control of STS assistive devices. Thirty healthy adult subjects participated in this study and carried out STS motion experiment of standing up naturally. The STS motions were recorded using a high-definition camera. The experimentally collected kinematic data and a link segment model of the human body were used to obtain the coordinates of joints and to calculate the coordinates, velocity, and momentum of center of gravity; the postures of human body during STS are also obtained. The relationship between human body parameters and motion parameters is analyzed by using Pearson correlation method. The STS motion is divided into 4 phases; the phases are differentiated in terms of STS motion characteristics and postures, and momentum of center of gravity of human body. The main factors determining the differences in STS motion among individuals are horizontal distance between hip joint and ankle joint, lower leg length, thigh length, and the length of the transition period. The horizontal distance between hip joint and ankle joint is positively correlated with the duration from motion begin to trunk stops flexing forward ( P = .021 < .05), but not so with the duration from motion begin to the end of phase 2 ( P = .15 > .05). The results suggest that when designing the sit-to-stand assistive devices, one should pay attention to the whole-body posture control in STS motion, such as the posture guidance of trunk and lower leg, and should carry out specific training according to different STS phases. Sit-to-stand assistive devices should provide the same horizontal distance between hip joint and ankle joint for different individuals during the STS motion. Transition period should be properly controlled, and the degree of freedom of the lower leg should not be limited. |
Author | Han, Xiaolong Li, Min Xue, Qiang Guo, Jingchen Li, Jin Yang, Shuo Zhang, Shouwei |
AuthorAffiliation | Tianjin Key Laboratory of Integrated Design and On-line Monitoring for Light Industry & Food Machinery and Equipment, College of Mechanical Engineering, Tianjin University of Science & Technology |
AuthorAffiliation_xml | – name: Tianjin Key Laboratory of Integrated Design and On-line Monitoring for Light Industry & Food Machinery and Equipment, College of Mechanical Engineering, Tianjin University of Science & Technology – name: a Tianjin Key Laboratory of Integrated Design and On-line Monitoring for Light Industry & Food Machinery and Equipment, College of Mechanical Engineering, Tianjin University of Science & Technology – name: b Academy of Medical Engineering and Translational Medicine, Tianjin University, Tianjin, China |
Author_xml | – sequence: 1 givenname: Jin surname: Li fullname: Li, Jin organization: Tianjin Key Laboratory of Integrated Design and On-line Monitoring for Light Industry & Food Machinery and Equipment, College of Mechanical Engineering, Tianjin University of Science & Technology – sequence: 2 givenname: Qiang surname: Xue fullname: Xue, Qiang organization: Tianjin Key Laboratory of Integrated Design and On-line Monitoring for Light Industry & Food Machinery and Equipment, College of Mechanical Engineering, Tianjin University of Science & Technology – sequence: 3 givenname: Shuo surname: Yang fullname: Yang, Shuo organization: Tianjin Key Laboratory of Integrated Design and On-line Monitoring for Light Industry & Food Machinery and Equipment, College of Mechanical Engineering, Tianjin University of Science & Technology – sequence: 4 givenname: Xiaolong surname: Han fullname: Han, Xiaolong organization: Tianjin Key Laboratory of Integrated Design and On-line Monitoring for Light Industry & Food Machinery and Equipment, College of Mechanical Engineering, Tianjin University of Science & Technology – sequence: 5 givenname: Shouwei surname: Zhang fullname: Zhang, Shouwei organization: Tianjin Key Laboratory of Integrated Design and On-line Monitoring for Light Industry & Food Machinery and Equipment, College of Mechanical Engineering, Tianjin University of Science & Technology – sequence: 6 givenname: Min surname: Li fullname: Li, Min organization: Tianjin Key Laboratory of Integrated Design and On-line Monitoring for Light Industry & Food Machinery and Equipment, College of Mechanical Engineering, Tianjin University of Science & Technology – sequence: 7 givenname: Jingchen surname: Guo fullname: Guo, Jingchen organization: Tianjin Key Laboratory of Integrated Design and On-line Monitoring for Light Industry & Food Machinery and Equipment, College of Mechanical Engineering, Tianjin University of Science & Technology |
BackLink | https://www.ncbi.nlm.nih.gov/pubmed/34087893$$D View this record in MEDLINE/PubMed |
BookMark | eNqFUUtvFSEYJabG3lZ_gYlh6YbKm5mNiWm1NbbRha4JA9wOykAdGJv593K9tWo3siE533l8cI7AQcrJA_Cc4BOCe_Xq6uwE_zlUUtw9AhsimESil_wAbBoqkOoVPwRHpXzFmDBF-RNwyDjuVNezDfj0ISQ_mRosNMnEtYQC8xbW0cNxmUyCQ3YrdMsc0jUsoaKaUakmORgSHL2JdVzhmpc2NW6JtTwFj7cmFv_s7j4GX969_Xx6gS4_nr8_fXOJLBdYok5wRkgvt50l2ErBB6a8MkYKpzrme6eoYcYrzo2ydmgIEb2T1lMnBm8JOwav9743yzB5Z32qs4n6Zg6TmVedTdD_TlIY9XX-oTvSMaVkM3h5ZzDn74svVU-hWB-jST4vRVPBlORY4V3Wi7-z7kN-f2MjsD3BzrmU2W_vKQTrXVn66kw_LKup-gcqG2qrIu8WDvE_Wr7X3uZY_Vy-xeXWz3rfyC-6UD1FFFOCJeYYNaQ9-idLa6ic |
CitedBy_id | crossref_primary_10_1016_j_mechmachtheory_2025_105986 crossref_primary_10_1016_j_clinbiomech_2023_106103 crossref_primary_10_7759_cureus_71449 crossref_primary_10_1016_j_ergon_2022_103396 crossref_primary_10_1080_01691864_2022_2132833 crossref_primary_10_1016_j_compbiomed_2024_109117 crossref_primary_10_1115_1_4066036 |
Cites_doi | 10.1007/s42235-018-0053-5 10.1016/j.ymssp.2017.01.051 10.1016/j.jbiomech.2020.110046 10.1016/j.msksp.2017.11.001 10.1016/0021-9290(90)90005-N 10.1016/j.neucli.2008.09.001 10.3390/s18041235 10.1371/journal.pone.0141675 10.1023/A:1020006909285 10.1016/j.gaitpost.2012.05.002 10.1016/j.apergo.2009.04.005 10.1016/S1672-6529(13)60249-8 10.1016/j.clinbiomech.2021.105288 10.1016/j.patrec.2018.03.020 10.1016/S0268-0033(00)00004-8 10.1093/ptj/70.8.511 10.1007/s42235-017-0006-4 10.1080/02703181.2016.1267293 10.1093/ptj/70.10.638 10.1016/j.gaitpost.2018.09.030 10.1016/S0749-0690(18)30930-3 10.1016/j.physio.2004.06.010 10.1016/j.jbiomech.2016.08.010 10.1016/0268-0033(95)00060-7 10.1016/j.jbiomech.2012.12.022 10.1093/ptj/82.9.866 10.1123/jab.2014-0189 |
ContentType | Journal Article |
Copyright | Lippincott Williams & Wilkins Copyright © 2021 the Author(s). Published by Wolters Kluwer Health, Inc. Copyright © 2021 the Author(s). Published by Wolters Kluwer Health, Inc. 2021 |
Copyright_xml | – notice: Lippincott Williams & Wilkins – notice: Copyright © 2021 the Author(s). Published by Wolters Kluwer Health, Inc. – notice: Copyright © 2021 the Author(s). Published by Wolters Kluwer Health, Inc. 2021 |
DBID | AAYXX CITATION CGR CUY CVF ECM EIF NPM 7X8 5PM |
DOI | 10.1097/MD.0000000000026208 |
DatabaseName | CrossRef Medline MEDLINE MEDLINE (Ovid) MEDLINE MEDLINE PubMed MEDLINE - Academic PubMed Central (Full Participant titles) |
DatabaseTitle | CrossRef MEDLINE Medline Complete MEDLINE with Full Text PubMed MEDLINE (Ovid) MEDLINE - Academic |
DatabaseTitleList | MEDLINE MEDLINE - Academic |
Database_xml | – sequence: 1 dbid: NPM name: PubMed url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed sourceTypes: Index Database – sequence: 2 dbid: EIF name: MEDLINE url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search sourceTypes: Index Database |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Medicine |
EISSN | 1536-5964 |
EndPage | e26208 |
ExternalDocumentID | PMC8183776 34087893 10_1097_MD_0000000000026208 00005792-202106040-00076 |
Genre | Journal Article Observational Study |
GrantInformation_xml | – fundername: Tianjin Natural Science Foundation grantid: 19JCZDJC33200 – fundername: Tianjin Natural Science Foundation grantid: 18JCQNJC75300 |
GroupedDBID | --- .-D .XZ .Z2 01R 0R~ 354 40H 4Q1 4Q2 4Q3 5GY 5RE 5VS 71W 77Y 7O~ AAAAV AAGIX AAHPQ AAIQE AAMOA AAQKA AARTV AASCR AAWTL AAXQO AAYEP ABASU ABBUW ABCQX ABDIG ABFRF ABOCM ABVCZ ABXVJ ABZAD ABZZY ACDDN ACEWG ACGFO ACGFS ACILI ACLDA ACWDW ACWRI ACXJB ACXNZ ACZKN ADGGA ADHPY ADNKB ADPDF AE6 AEFWE AENEX AFBFQ AFDTB AGOPY AHOMT AHQNM AHVBC AIJEX AINUH AJCLO AJIOK AJNWD AJNYG AJZMW AKCTQ AKULP ALKUP ALMA_UNASSIGNED_HOLDINGS ALMTX AMJPA AMKUR AMNEI AOHHW AOQMC BQLVK CS3 DIWNM DU5 E.X EBS EEVPB ERAAH EX3 F2K F2L F2M F2N F5P FCALG FD6 FIJ FL- GNXGY GQDEL GROUPED_DOAJ H0~ HLJTE HYE HZ~ H~9 IKREB IKYAY IN~ IPNFZ JK3 JK8 K8S KD2 KMI KQ8 L-C N9A N~7 N~B O9- OAG OAH OB2 OHH OK1 OL1 OLB OLG OLH OLU OLV OLY OLZ OPUJH OUVQU OVD OVDNE OVEED OVIDH OVLEI OWV OWW OWZ OXXIT P2P RIG RLZ RPM RXW S4R S4S TAF TEORI TSPGW UNMZH V2I VVN W3M WOQ WOW X3V X3W XYM YFH YOC ZFV ZY1 AAYXX CITATION 8L- ACIJW AWKKM CGR CUY CVF ECM EIF NPM ODA 7X8 5PM ADSXY |
ID | FETCH-LOGICAL-c4506-85431196f8c10c654b37e7aa65d783e9d72a3ae744a7ccb3e9159d6ce2d5bec13 |
ISSN | 0025-7974 1536-5964 |
IngestDate | Thu Aug 21 13:45:51 EDT 2025 Thu Jul 10 23:12:09 EDT 2025 Wed Feb 19 02:24:53 EST 2025 Thu Apr 24 23:05:21 EDT 2025 Sun Jul 06 05:03:24 EDT 2025 Fri May 16 03:50:51 EDT 2025 |
IsDoiOpenAccess | true |
IsOpenAccess | true |
IsPeerReviewed | true |
IsScholarly | true |
Issue | 22 |
Language | English |
License | Copyright © 2021 the Author(s). Published by Wolters Kluwer Health, Inc. This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial License 4.0 (CCBY-NC), where it is permissible to download, share, remix, transform, and buildup the work provided it is properly cited. The work cannot be used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc/4.0 |
LinkModel | OpenURL |
MergedId | FETCHMERGED-LOGICAL-c4506-85431196f8c10c654b37e7aa65d783e9d72a3ae744a7ccb3e9159d6ce2d5bec13 |
Notes | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 ObjectType-Undefined-3 |
OpenAccessLink | http://dx.doi.org/10.1097/MD.0000000000026208 |
PMID | 34087893 |
PQID | 2537640701 |
PQPubID | 23479 |
ParticipantIDs | pubmedcentral_primary_oai_pubmedcentral_nih_gov_8183776 proquest_miscellaneous_2537640701 pubmed_primary_34087893 crossref_primary_10_1097_MD_0000000000026208 crossref_citationtrail_10_1097_MD_0000000000026208 wolterskluwer_health_00005792-202106040-00076 |
PublicationCentury | 2000 |
PublicationDate | 20210604 2021-06-04 2021-Jun-04 |
PublicationDateYYYYMMDD | 2021-06-04 |
PublicationDate_xml | – month: 06 year: 2021 text: 20210604 day: 04 |
PublicationDecade | 2020 |
PublicationPlace | United States |
PublicationPlace_xml | – name: United States – name: Hagerstown, MD |
PublicationTitle | Medicine (Baltimore) |
PublicationTitleAlternate | Medicine (Baltimore) |
PublicationYear | 2021 |
Publisher | Lippincott Williams & Wilkins |
Publisher_xml | – name: Lippincott Williams & Wilkins |
References | Pourahmadi (R1-20250524) 2018; 35 Odding (R6-20250524) 2001; 17 Dall (R3-20250524) 2010; 41 Ruszala (R22-20250524) 2005; 91 Schenkman (R13-20250524) 1990; 70 Suriyaamarit (R35-20250524) 2019; 67 Gordon (R31-20250524) 2014 Silva (R7-20250524) 2017; 40 Janssen (R24-20250524) 2002; 82 Martinez-Hernandez (R2-20250524) 2019; 118 Rob (R10-20250524) 2018; 18 Jeng (R12-20250524) 1990; 70 Schenkman (R28-20250524) 1996; 11 Sturnieks (R4-20250524) 2008; 38 Yu (R34-20250524) 2000; 15 Stevermer (R11-20250524) 2016; 32 Roldán-Jiménez (R25-20250524) 2015; 10 Mombaur (R32-20250524) 2017 Rea (R27-20250524) 2018; 15 Hurley (R8-20250524) 2016; 34 Diakhaté (R23-20250524) 2013; 46 Kralj (R16-20250524) 1990; 23 Yamasaki (R14-20250524) 2016; 49 Pourahmadi (R9-20250524) 2017 Allouche (R21-20250524) 2018; 15 Rea (R26-20250524) 2013; 10 Wang (R36-20250524) 2018; 113 Burnfield (R18-20250524) 2012; 36 Cilli (R37-20250524) 2021; 83 Wolfson (R5-20250524) 1985; 1 Norman-Gerum (R17-20250524) 2020; 112 |
References_xml | – volume: 15 start-page: 647 year: 2018 ident: R21-20250524 article-title: Design and control of an assistive device for the study of the post-stroke sit-to-stand movement publication-title: Journal of Bionic Engineering doi: 10.1007/s42235-018-0053-5 – volume: 113 start-page: 90 year: 2018 ident: R36-20250524 article-title: Fault classification with discriminant analysis during sit-to-stand movement assisted by a nursing care robot publication-title: Mechanical Systems and Signal Processing doi: 10.1016/j.ymssp.2017.01.051 – volume: 112 start-page: 110046 year: 2020 ident: R17-20250524 article-title: Comprehensive description of sit-to-stand motions using force and angle data publication-title: J Biomech doi: 10.1016/j.jbiomech.2020.110046 – volume: 35 start-page: 95 year: 2018 ident: R1-20250524 article-title: Test-retest reliability of sit-to-stand and stand-to-sit analysis in people with and without chronic non-specific low back pain publication-title: Musculoskeletal Science and Practice doi: 10.1016/j.msksp.2017.11.001 – volume: 23 start-page: 1123 year: 1990 ident: R16-20250524 article-title: Analysis of standing up and sitting down in humans: Definitions and normative data presentation publication-title: J Biomech doi: 10.1016/0021-9290(90)90005-N – volume: 38 start-page: 467 year: 2008 ident: R4-20250524 article-title: Balance disorders in the elderly publication-title: Neurophysiol Clinique/Clinical Neurophysiology doi: 10.1016/j.neucli.2008.09.001 – volume: 18 start-page: 1235 year: 2018 ident: R10-20250524 article-title: Older adults with weaker muscle strength stand up from a sitting position with more dynamic trunk use publication-title: Sensors doi: 10.3390/s18041235 – volume: 40 start-page: 57 year: 2017 ident: R7-20250524 article-title: Trunk kinematics related to generation and transfer of the trunk flexor momentum are associated with sit-to-stand performance in chronic stroke survivors publication-title: NeuroRehabilitation – volume: 10 start-page: e0141675 year: 2015 ident: R25-20250524 article-title: Muscular activity and fatigue in lower-limb and trunk muscles during different sit-to-stand tests publication-title: PLoS One doi: 10.1371/journal.pone.0141675 – start-page: 58 year: 2017 ident: R32-20250524 article-title: How to best support sit to stand transfers of geriatric patients: Motion optimization under external forces for the design of physical assistive devices publication-title: J Biomech – volume: 17 start-page: 1033 year: 2001 ident: R6-20250524 article-title: Determinants of locomotor disability in people aged 55 years and over: The Rotterdam Study publication-title: Eur J Epidemiol doi: 10.1023/A:1020006909285 – volume: 36 start-page: 516 year: 2012 ident: R18-20250524 article-title: Kinematic and electromyographic analyses of normal and device-assisted sit-to-stand transfers publication-title: Gait Posture doi: 10.1016/j.gaitpost.2012.05.002 – volume: 41 start-page: 58 year: 2010 ident: R3-20250524 article-title: Frequency of the sit to stand task: an observational study of free-living adults publication-title: Appl Ergon doi: 10.1016/j.apergo.2009.04.005 – volume: 10 start-page: 488 year: 2013 ident: R26-20250524 article-title: A procedure for the design of novel assisting devices for the sit-to-stand publication-title: Journal of Bionic Engineering doi: 10.1016/S1672-6529(13)60249-8 – year: 2014 ident: R31-20250524 article-title: Research Methods in Biomechanics publication-title: the United States of America: Human Kinetics – volume: 83 start-page: 105288 year: 2021 ident: R37-20250524 article-title: The effect of body weight on joint torques in teenagers: Investigation of sit-to-stand movement publication-title: Clinical Biomechanics doi: 10.1016/j.clinbiomech.2021.105288 – volume: 118 start-page: 32 year: 2019 ident: R2-20250524 article-title: Probabilistic identification of sit-to-stand and stand-to-sit with a wearable sensor publication-title: Pattern Recognition Letters doi: 10.1016/j.patrec.2018.03.020 – volume: 15 start-page: 449 year: 2000 ident: R34-20250524 article-title: The effects of the lower extremity joint motions on the total body motion in sit-to-stand movement publication-title: Clin Biomech doi: 10.1016/S0268-0033(00)00004-8 – volume: 70 start-page: 511 year: 1990 ident: R12-20250524 article-title: Reliability of a clinical kinematic assessment of the sit-to-stand movement publication-title: Phys Ther doi: 10.1093/ptj/70.8.511 – volume: 15 start-page: 83 year: 2018 ident: R27-20250524 article-title: Functional design for customizing sit-to-stand assisting devices publication-title: J Bionic Eng doi: 10.1007/s42235-017-0006-4 – volume: 34 start-page: 169 year: 2016 ident: R8-20250524 article-title: The effect of age and seat height on sit-to-stand transfer biomechanics and muscle activation publication-title: Phys Occup Ther Geriatr doi: 10.1080/02703181.2016.1267293 – volume: 70 start-page: 638 year: 1990 ident: R13-20250524 article-title: Whole-body movements during rising to standing from sitting publication-title: Phys Ther doi: 10.1093/ptj/70.10.638 – volume: 67 start-page: 85 year: 2019 ident: R35-20250524 article-title: Mechanical work kinematics and kinetics during sit-to-stand in children with and without spastic diplegic cerebral palsy publication-title: Gait Posture doi: 10.1016/j.gaitpost.2018.09.030 – volume: 1 start-page: 649 year: 1985 ident: R5-20250524 article-title: Gait and balance in the elderly. Two functional capacities that link sensory and motor ability to falls publication-title: Clin Geriatr Med doi: 10.1016/S0749-0690(18)30930-3 – volume: 91 start-page: 35 year: 2005 ident: R22-20250524 article-title: An evaluation of equipment to assist patient sit-to-stand activities in physiotherapy publication-title: Physiotherapy doi: 10.1016/j.physio.2004.06.010 – volume: 49 start-page: 3268 year: 2016 ident: R14-20250524 article-title: Spatiotemporal modular organization of muscle torques for sit-to-stand movements publication-title: J Biomech doi: 10.1016/j.jbiomech.2016.08.010 – volume: 11 start-page: 153 year: 1996 ident: R28-20250524 article-title: Sit to stand from progressively lower seat heights—alterations in angular velocity publication-title: Clin Biomech doi: 10.1016/0268-0033(95)00060-7 – volume: 46 start-page: 879 year: 2013 ident: R23-20250524 article-title: Effects of seat–thigh contact on kinematics performance in sit-to-stand and trunk flexion tasks publication-title: J Biomech doi: 10.1016/j.jbiomech.2012.12.022 – volume: 82 start-page: 866 year: 2002 ident: R24-20250524 article-title: Determinants of the sit-to-stand movement: a review publication-title: Phys Ther doi: 10.1093/ptj/82.9.866 – start-page: 01 year: 2017 ident: R9-20250524 article-title: Kinematics of the spine during sit-to-stand using motion analysis systems: a systematic review of literature publication-title: J Sport Rehabil – volume: 32 start-page: 07 year: 2016 ident: R11-20250524 article-title: Kinematic and kinetic indicators of sit-to-stand publication-title: J Appl Biomech doi: 10.1123/jab.2014-0189 |
SSID | ssj0013724 |
Score | 2.379273 |
Snippet | Sit-to-stand (STS) motion is one of the most important and energy-consuming basic motions in everyday life. Kinematic analysis provides information regarding... |
SourceID | pubmedcentral proquest pubmed crossref wolterskluwer |
SourceType | Open Access Repository Aggregation Database Index Database Enrichment Source Publisher |
StartPage | e26208 |
SubjectTerms | Adult Algorithms Ankle Joint - physiology Biomechanical Phenomena - physiology Body-Weight Trajectory Dyskinesias - rehabilitation Hip Joint - physiology Human Body Humans Leg - anatomy & histology Male Movement - physiology Observational Study Postural Balance - physiology Posture - physiology Range of Motion, Articular - physiology Self-Help Devices - adverse effects Thigh - anatomy & histology Torso - physiology |
Title | Kinematic analysis of the human body during sit-to-stand in healthy young adults |
URI | https://ovidsp.ovid.com/ovidweb.cgi?T=JS&NEWS=n&CSC=Y&PAGE=fulltext&D=ovft&AN=00005792-202106040-00076 https://www.ncbi.nlm.nih.gov/pubmed/34087893 https://www.proquest.com/docview/2537640701 https://pubmed.ncbi.nlm.nih.gov/PMC8183776 |
Volume | 100 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV3vi9MwGA66AxFE_G39cUTwm-bs2rRJP6rbcZzbncIm_VaSNvOK0orrkPnX-yZp2tUbcroPZWRZG_o8efPmTd4nCL0UPOYwDkgSBpEkdBUrIimnBIZeQZO8SCjV2cjzs_hkSU_TKO0P4zTZJY08yn_tzSv5H1ShDHDVWbL_gGx3UyiA74AvXAFhuF4J4w_gIjrJ1V5bRLuS9ug9WRdbl4i4LhvS1MSEDnSQwyZAbl9tdXe3MhzrXU913i66axf0HVQt7Y7cLm4wM9sATsuOXOnGxEY_Ad--dLbERaMvNnVv64yhS0sBdret2oYdArs9ig4sZUyixEqQH6k9Zc68-v4Oj2wScmstlVbD53sNuRUInk-svqT9dLWHstln59nxcjbLFtN0cR0dBDBfCEbo4PzzdDrpF5SYPd_YtdAJUCXszZ6HDJ2USzOPyxtob_2s9eaG9VeT27DjoSzuoNvt1AK_tTy5i66p6h664XC8jz52dMGOLrheYaALNnTBmi7Y0gXv0gWXFW7pgg1dsKXLA7Q8ni7en5D2QA2S0wjw41r4AEzuiudjP48jKkOmmBBxVDAeqqRggQiFYtBPWZ5LKAFnt9BnxhUR9PVx-BCNqrpSjxEuxiEV3JdMKkGDPEqon4eqAIeTKyVF4qHAvcEsb9Xm9aEn3zK362E-yf587R563f3puxVb-Xv1Fw6aDIyiXukSlao36yzQIkUURrOxhx5ZqLobhtTnDLx0D7EBiF0FLbg-_KUqL4zwOhi1kLHYQ2QAd2YhMO2LWBIQ3V-0KJXRbGDxkyu08ym62feyZ2jU_Nio5-DuNvLQhIkOW0L_BtM-pZQ |
linkProvider | Ovid |
linkToHtml | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwlV3db9MwED9BJwESmvgmfBoJ5QmPNHFi56EPVZtRtqVMase2p8hOXFGBkolkoP738zlpoUwgkRdHsZMH3zn3s-_udwBvpYiEsQOKBn6oKFtEmiomGDWmV7I4L2LGMBs5nUaTE3ZwFp510RaYC4PZZ_XFHjb2P403WA8HN4bzwcHMnSans0Hpjmajwbl7PPyQ2HNqjJJwx4Pqx6Jxh1MbfxXy2Dc6YLY0EUbNWZ_TTdiJQp97Pdj59DlJxr_8Ddxnm-KuBmKv-Yli_j4dtxyH7YX87WLbhl0DptfjK-_-rND3XX-1oe-_GbD9e7DbIU8ybFXlPtzQ5QO4lXa-9YdwfGgaS-BKZMdUQqoFMQCR2EJ-RFXFirRpjaReNrSpqD2IIMuStOmUK7LCnwexpB71IzjZT-ajCe3qLdCchV5EBebFmxW5EHnfy6OQqYBrLmUUFlwEOi64LwOpuREjz3NlnhgsVGBJsSI0qtAPHkOvrEr9FEjRD5gUnuJKS-bnYcy8PNCFwSNCayVjB_z1DGZ5R0aONTG-ZWuneDrO_px2B95tXrpouTj-PfzNWjSZWTPoCJGlri7rzEcOG7OT9foOPGlFtflgwDzBDYhzgG8JcTMA-bi3e8rlF8vLbXQ-4DxygG6JO2tFkP1NKZ_95_jXcHsyT4-yo4_Tw-dwB3tt7Bp7Ab3m-6V-aVBSo151Kn4FCyIFcQ |
linkToPdf | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwlV3da9swED-6FMpgjH3P-9Rg-Gkaji1b8oMfSuysa5c0kHZrn4xkKyy02GVxN_Lf7yTb2bKOwfwiY8nC6M7ST7q73wG8lSISuA4oGvihomwRaaqYYBSXXsnioowZM9HIk2l0cMoOz8KzHegtpib4bHX13hR2mjY3Jh2O2ReeJIdzdzQfJefuNPsyT6bubP9DZo-pjZOEO0vHydpNk_r7onHT46TnZ5ykLUlhexkCdnELdoWIPDaA3ePPWZb-sjtwn22SvCLU7nmK_t7N9lp2A6De9LO886M2NvDVhXWB_20hG9-Dux0CJfutytyHHV09gL1JZ2N_CLMjLCyRK5EdYwmpFwSBIrEJ_YiqyzVpwxvJatnQpqb2QIIsK9KGVa7J2kwixJJ7rB7B6Tg7GR3QLu8CLVjoRVSY-Hj8MxeiGHpFFDIVcM2ljMKSi0DHJfdlIDVHcfKiUPgEMVFpUouVIarEMHgMg6qu9FMg5TBgUniKKy2ZX4Qx84pAl4hLhNZKxg74_QjmRUdKbnJjXOa9cXyS5n8OuwPvNi9dtZwc_27-phdNjv-OMYjIStfXq9w3XDa4o_WGDjxpRbXpMGCe4AjmHOBbQtw0MLzc2zXV8qvl50bdDziPHKBb4s5bEdjvC3ns4wSF--3IuHRag-iz_2z_GvZQ5fNPH6dHz-G2qbQubOwFDJpv1_olgqVGveo0_Cf-Owb9 |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Kinematic+analysis+of+the+human+body+during+sit-to-stand+in+healthy+young+adults&rft.jtitle=Medicine+%28Baltimore%29&rft.au=Li%2C+Jin&rft.au=Xue%2C+Qiang&rft.au=Yang%2C+Shuo&rft.au=Han%2C+Xiaolong&rft.date=2021-06-04&rft.issn=1536-5964&rft.eissn=1536-5964&rft.volume=100&rft.issue=22&rft.spage=e26208&rft_id=info:doi/10.1097%2FMD.0000000000026208&rft.externalDBID=NO_FULL_TEXT |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0025-7974&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0025-7974&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0025-7974&client=summon |